40
BI 29.08.03 Sci 2006 YXLON. The reason why 1 YXLON International Industrial Computed Tomography

Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 1

YXLON International

Industrial Computed Tomography

Page 2: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 2

CT - applications

Page 3: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 3

Computed Tomography (Line Detector)

CT - principles

Page 4: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 4

0

2000

4000

6000

8000

10000

12000

Detektorkanäle

Zähl

rate

absorption profile

sinogram reconstructed image

CT - principles

Page 5: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 5

volume data

stack of 2D images

CT - principles

Page 6: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 6

Computed Tomography (Flat Panel)

CT - principles

Page 7: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 7

volume data

set of projections

CT - principles

Page 8: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 8

PU foam

Al foam

Al foam/steel compound

CT - applicationsVizualization Vizualization / NDT // NDT /

geometrical measurementgeometrical measurement

Page 9: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 9

NDTNDTAluminum casting

CT - applications

Page 10: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 10

Visualization Visualization tool for

injection moulding

CT - applications

Page 11: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 11

Geometrical measurement

cylinder/crank case

CT - applications

Page 12: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 12

VisualizationVisualizationSandstone sculpture(Cathedral of Mainz)

CT - applications

Page 13: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 13

NDTNDTcasting defect in

cylinder/crank case

CT - applications

Page 14: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 14

NDTNDTheater plug

CT - applications

Page 15: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 15

CT - applications

NDTNDTwelding seam

Page 16: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 16

CT - applications

Vizualization Vizualization / NDT/ NDTceramic sphere

Page 17: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 17

CT - applications

Vizualization Vizualization / NDT/ NDTcylinder head

Page 18: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 18

CT - applications

Vizualization Vizualization / NDT/ NDTmounted device

Page 19: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 19

CT - applications

Vizualization Vizualization / NDT // NDT /geometrical measurementgeometrical measurement

truck tire

Page 20: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 20

- defect analysis

- position control

- geometrical measuring

2D images orvolume data surface reconstruction

(CAD model)

CAD modelnominal/actual comparison

- nominal/actual comparison

- rapid prototyping

- FE simulations

polygon extraction(STL model)

CT - applications

Page 21: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 21

nominal/nominal/actual actual value comparisonvalue comparison

CT - applications

Page 22: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 22

solidification solidification simulationsimulation

CT - applications

Page 23: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 23

Reverse EngineeringReverse EngineeringReproduction of a cylinder head (1937 model)

CT - applications

Page 24: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 24

CT - systems

General General remarksremarksresolution vs. object size

Page 25: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 25

225 kV Minifocus X-ray source(available with Microfocus)

< 220 mm Ø< 500 mm height< 15 kg

Line detector array < 50μm pitch< 1% contrast resolution(available with Flat-Panel)

SmallSmall for objects with

CT - systems

4-axis high accuracy manipulator (+/- 10 µm)

Page 26: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 26

CT - systems

160 ... 450 kV X-ray source

Line detector array120 μm / 0.5% or Flat-Panel400 µm / 1 %

< 335 mm Ø< 500 mm height< 30 kg

CompactCompact for objects with

5-axis high load manipulator (+/- 50 µm)

Page 27: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 27

< 525 / 900 mm Ø< 1,000 mm height< 150 kg

Line detector array 100 μm pitch0.1% contrast resolution

CT - systems

450 kV X-ray source225 kV Minifocus

MediumMedium for objects with

5-axis high load manipulator (+/- 50 µm)

Page 28: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 28

450 kV X-ray source

Line detector array(100 μm / 0.1%) and Flat-Panel(400 µm / 1 %)

CT - systems

< 525 / 900 mm Ø< 1,200 mm height< 50 kg

MediumMedium for objects with

6-axis high accuracy manipulator (+/- 25 µm)

Page 29: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 29

2.5 MeV linear accelerator

< 800 / 1300 mm Ø< 1,500 mm height< 350 kg

CT - systems

Line detector array600 μm pitch (250 µm available)0.5% contrast resolution

LargeLarge for objects with

5-axis high load manipulator (+/- 50 µm)

Page 30: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 30

DetectorDetector--Capabilities Capabilities for geometrical measurement

CT - systems

Page 31: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 31

Line detector array170 kVAluminum

CT - systems

ComparisonComparisonlow energy appl.

Page 32: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 32

CT - systems

ComparisonComparisonlow energy appl.

Flat Panel170 kVAluminum

Page 33: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 33

CT - systems

ComparisonComparisondynamic range

Page 34: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 34

CT - systems

ComparisonComparisonhigh energy appl.

Line detector array450 kVAluminum

Page 35: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 35

CT - systems

ComparisonComparisonhigh energy appl.

Flat Panel450 kVAluminum

Page 36: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 36

Computed Tomography (3D-CT)

CT - principles

Page 37: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 37

CT - systems

ComparisonComparisonLDA vs. Flat Panel

speedspatial resolution

contrast resolutiondetectability

VisualizationNDT

geometrical measurementreverse engineering

Page 38: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 38

CT - systems

CapabilitiesCapabilities

YXLON-CT-systems are used withLDA (2D-CT) or FlatPanel(3D-CT) or both combinedMicro-, Mini-, Macro-X-ray sourcesRadioisotopes, Linear acceleratorson-top-equipment

YXLON-CT-systems are usable for any material (as long as absorbing) any object (as long as penetrable)any application (as far as thinkable)

Page 39: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 39

FeaturesFeatures

CT - systems

YXLON-CT-systems are optimized forhigh performance (speed, resolution)high throughput (in-line reconstruction)high accuracy (manipulation)high reliability (industrial design, remote service)

YXLON-CT-systems includeeasy-to-use operator interface3D-visualizationimage analysis & measurement toolsopen interfaces

Page 40: Industrial Computed Tomography...Industrial Computed Tomography Sci 2006 BI 29.08.03 YXLON. The reason why 2 CT - applications Sci 2006 BI 29.08.03 YXLON. The reason why 3 Computed

BI 2

9.08

.03

Sci2

006

YXLON. The reason why 40

YXLON International X-Ray GmbH

www.yxlon.com