Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 2500Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-2500-7
LEFT VIEWFRONT VIEW
TOP VIEW
REAR VIEW
BOTTOM VIEW
20 1/4(514 mm)
CENTER OFGRAVITY
31 1/8(791 mm)
37 13/16(960 mm)
49"(1245 mm)
1 1/2" GAS TRAIN
24"(610 mm)
3/4(19 mm)
34 1/2(876 mm)
� 1/2(Ø13 mm)
2 1/2(63 mm)
14 13/32(367 mm)
CENTER OFGRAVITY
29 1/8(740 mm)
24"(610 mm)
55 1/2(1410 mm)
35 5/8(905 mm)
41 1/8(1045 mm)
24"(610 mm)
CENTER OFGRAVITY
17 1/4(438 mm)
46"(1168 mm)
4 1/2(114 mm)
7 1/8(181 mm)
16"(406 mm)
46 1/2(1181 mm)
� 8"(203 mm)
POWERSERVICEBOX9 3/4
(248 mm)
Ø4"(76 mm)INLET
Ø4"(76 mm)OUTLET
4"ASME FLANGE
3/4" NPT(2 PLCS.)
� 8"(203 mm)CAT. IV
(*REFER TO IOM FOR CAT II VENT)
33 5/16(848 mm)
8 3/8(213 mm)
15 3/4(400 mm)
43 3/4(1111 mm)
36"(914 mm)
1 1/2" GAS TRAIN
40 1/4(1022 mm)
45 7/8(1165mm)
� 10"(254 mm)
CAT. I VENT
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 10.5* @ 230V
Input BTU/hr. 2,500,000 / 733 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 2,147,500 / 629 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, NEU, GND) Operating Weight 1,249 lbs. / 567 kgs.
208-240 VAC / 1PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body Dungs MBC 2500 High Limit (Manual Reset) Jumo
Firing Valve Honeywell B200T1066 1-1/2" High Limit (Auto Reset) Jumo
Main Ball Valve 1-1/2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25M Blower Motor American Fan 3 HP - FLA 8
Ignition Control Honeywell RM7895C Relief Valve - MB 1" x 1-1/4" set @ 50 psi
Operating Control HeatNet® Relief Valve - MW 3/4" x 3/4" set @ 125 psi
Flow Switch ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 267.5 Sq. Ft. / 24.85 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 12.1 gal / 45.80 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
214.8 13.5 10.05 29.6 171.8 10.8 6.45 19.0 143.2 9.0 3.71 10.9 122.7 7.7 2.79 8.2
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
6355 24022 4237 16015 3178 12011 2542 9609 2118 8007 1816 6863
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
RSUB-83 REV D
FUTERA XLF 2500
OUTDOOR UNIT 55[1397 mm]
24[610 mm]
57 1/8[1450 mm]
34[863 mm]
23 9/16[598 mm]
14 13/16[376 mm]
20 3/16[512 mm]
37 13/16[961 mm]
42 13/16[1088 mm]
53 7/8[1368 mm]
36 9/16[929 mm]
38 5/16[973 mm]
42 1/16[1069 mm]
50[1271 mm]
63 1/8[1603 mm]
33 5/16[846 mm]
1[25 mm]
16 1/16[408 mm]
40 5/16[1024 mm]
76 13/16[1951 mm]
5 1/16[129 mm]
14 9/16[369 mm]
Ø4[102 mm]
ASME FLANGEINLET
Ø4[102 mm]
ASME FLANGEOUTLET
Ø8[204 mm]
EXHAUST FLUE
9 3/4[248 mm]
19 9/16[496 mm]
CENTER OFGRAVITY
CENTER OFGRAVITY
FRONT VIEW SIDE VIEW BACK VIEW
TOP VIEW
29 5/8[752 mm]
RSUB-136 REV C
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 3000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-3000-10
LEFT VIEWFRONT VIEW
TOP VIEW
REAR VIEW
BOTTOM VIEW
24"(610 mm)
34 1/2(876 mm)
3/4(19 mm)
� 1/2(Ø13 mm)
2 1/2(63 mm)
20 11/32(517 mm)
CENTER OFGRAVITY
31 1/8(791 mm)
37 13/16(960 mm)
49"(1245 mm)
1 1/2" GAS TRAIN
14 1/4(362 mm)
CENTER OFGRAVITY
29 1/8(740 mm)
60"(1524 mm)
24"(610 mm)
25 5/8(651 mm)
CENTER OFGRAVITY17 1/4
(438 mm)
50 1/2(1283 mm)
35 5/8(905 mm)
36"(914 mm)
41 1/8(1045 mm)43 3/4
(1111 mm)
8 3/8(213 mm)
15 3/4(400 mm)
4"ASME FLANGE
� 4"(102 mm)OUTLET
37 13/16(960 mm)
3/4" NPT(2 PLCS.)
� 8"(203 mm)
CAT. IV VENT(*REFER TO IOM FOR CAT. II VENT)
4 1/2(114 mm)
7 1/8(181 mm)
16"(406 mm)
9 3/4(248 mm)
POWERSERVICEBOX
� 8"(203 mm)
51"(1295 mm)
� 4"(102 mm)
INLET44 3/4
(1137 mm)
1 1/2" GAS TRAIN
� 10"(254 mm)
CAT. I VENT
45 7/8(1165 mm)
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 10.5* @ 230V
Input BTU/hr. 3,000,000 / 879 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 2,622,000 / 768 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, NEU, GND) Operating Weight 1,355 lbs. / 615 kgs.
208-240 VAC/1 ph/60 hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body Dungs MBC 2500 High Limit (Manual Reset) Jumo
Firing Valve Honeywell B200T1066 1-1/2" High Limit (Auto Reset) Jumo
Main Ball Valve 1-1/2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25M Blower Motor American Fan 3 HP - FLA 8
Ignition Control Honeywell RM7895C Relief Valve - MB 1-1/4" x 1-1/2" set @ 50 psi
Operating Control HeatNet® Relief Valve - MW 3/4" x 3/4" set @ 125 psi
Flow Switch ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 325.0 Sq. Ft. / 30.19 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 12.8 gal / 48.45 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
262.2 16.5 15.20 44.8 209.8 13.2 9.73 28.7 174.8 11.0 6.75 19.9 149.8 9.5 4.65 13.7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
7590 28690 5060 19127 3795 14345 3036 11476 2530 9563 2169 8197
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
RSUB-84 REV F
FUTERA XLF 3000
OUTDOOR UNIT
24[610 mm]
61 3/8[1560 mm]
32 3/4[831 mm]
15 1/8[384 mm]
25 3/16[640 mm]
CENTER OFGRAVITY
55[1397 mm]
37 13/16[961 mm]
42 13/16[1088 mm]
53 7/8[1368 mm]
19 15/16[506 mm]
1[25 mm]
CENTER OFGRAVITY
36 9/16[928 mm]
40 3/8[1026 mm]
42 1/16[1069 mm]
50[1270 mm]
61 5/8[1565 mm]
37 13/16[960 mm]
16 1/16[408 mm]
44 3/4[1137 mm]
76 13/16[1950 mm]
Ø4[102 mm]
ASME FLANGEINLET
9 5/8[245 mm]
19 7/16[493 mm]
14 9/16[369 mm]
5[127 mm]
Ø4[102 mm]
ASME FLANGEOUTLET
Ø8[204 mm]
EXHAUST FLUE
FRONT VIEW SIDE VIEWBACK VIEW
TOP VIEW
29 5/8[752 mm]
RSUB-137 REV C
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 3500Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-3500-6
LEFT VIEWFRONT VIEW
TOP VIEW
REAR VIEW
BOTTOM VIEW
34 1/2(876 mm)
3/4(19 mm)
� 1/2(13 mm)
(4 PLCS.)
24"(610 mm)
2 1/2(63 mm)
31 1/8(791 mm)
37 13/16(960 mm)
50 1/2(1283 mm)
19 15/16(500 mm)
CENTER OFGRAVITY
14 13/32(367 mm)
CENTER OFGRAVITY
29 1/8(740 mm)
64 1/2(1638 mm)
24"(610 mm)
44 9/16(1132 mm)
2" NG & 1 ½" LPNPT GAS TRAIN
27 31/32(710 mm)
CENTER OFGRAVITY
25 9/16(649 mm)
20 7/16(519 mm)
35 5/8(905 mm)
36"(914 mm)
41 1/8(1045 mm)
43 3/4(1111 mm) 4 1/2
(114 mm)
3/4" NPT(2 PLCS.)
� 10"(254 mm)
CAT. IV VENT(*REFER TO IOM FOR CAT. II VENT)
� 4"(102 mm)OUTLET
42 5/16(1075 mm)
4"ASME FLANGE
8 1/2(216 mm)
� 4"(102 mm)
INLET
POWERSERVICEBOX
9 3/4(248 mm)
� 10"(254 mm)
AIR INTAKE
7 1/8(181 mm)
15"(381 mm)
55 1/2(1410 mm)
50 3/4(1289 mm)
� 12"(305 mm)
CAT. I VENT
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 10.5* @ 230V
Input BTU/hr. 3,500,000 / 1,026 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 3,052,000 / 894 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, NEU, GND) Operating Weight 1470 lbs. / 667 kgs
208-240 VAC / 1PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body Dungs MBC 4000 High Limit (Manual Reset) Jumo
Firing Valve Honeywell B200T1066 2" High Limit (Auto Reset) Jumo
Main Ball Valve 2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25M Blower Motor American Fan 3 HP - FLA 8
Ignition Control Honeywell RM7895C Relief Valve - MB 1-1/2" x 2" set @ 50 psi
Operating Control HeatNet® Relief Valve - MW 3/4" x 1" set @ 125 psi
Flow Switch ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 377.0 Sq Ft / 35.02 Sq M Design Data Max. 160 psig & 250°F
Water Volume 13.4 gal / 50.72 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
305.2† 19.3† 20.26 59.7 244.2 15.4 13.40 39.5 203.5 12.8 9.56 28.2 174.4 11.0 7.19 21.2
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
8813 33313 5875 22209 4407 16657 3525 13325 2938 11104 2518 9518
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
RSUB-85 REV C
FUTERA XLF 3500
OUTDOOR UNIT
19 7/16[493 mm]
42 7/8[1089 mm]
53 7/8[1368 mm]
42 5/16[1075 mm]
36 9/16[929 mm]
38 5/16[973 mm]
42[1069 mm]
63 3/16[1605 mm]
1[25 mm]
15 1/16[382 mm]
25 9/16[649 mm]
77 1/8[1959 mm]
� 4[102 mm]
ASME FLANGEINLET
� 4[102 mm]
ASME FLANGEOUTLET
9 5/8[245 mm]
19 7/16[493 mm]
� 10[255 mm]
EXHAUST FLUE
55[1397 mm]
14 1/4[361 mm]
24[610 mm]
28 5/16[719 mm]
65 7/8[1673 mm]
35 5/8[904 mm]
CENTER OFGRAVITY
CENTER OFGRAVITY
FRONT VIEW SIDE VIEWBACK VIEW
TOP VIEW
37 7/8[962 mm]
29 5/8[752 mm]
RSUB-138 REV D
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 4000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-4000-9
LEFT VIEWFRONT VIEW
TOP VIEW
REAR VIEW
BOTTOM VIEW
29 1/8(740 mm) 14 5/8
(371 mm)CENTER OF
GRAVITY
24"(610 mm)
69"(1753 mm)
19 1/4(489 mm)
CENTER OFGRAVITY
31 1/8(791 mm)
37 13/16(960 mm)
49 23/32(1283 mm)
34 1/2(876 mm)
3/4(19 mm)
� 1/2(13 mm)
(4 PLCS.)
24"(610 mm)
2 1/2(63 mm)
2" NG & 1 ½" LPNPT GAS TRAIN
35 5/8(905 mm)
36"(914 mm)41 1/8
(1045 mm) 43 3/4(1111 mm)
42 7/8(1089 mm)
4 1/2(114 mm)
7 1/8(181 mm)
15"(381 mm)
� 10"(254 mm)
AIR INTAKE
60"(1524 mm)
8 1/2(216 mm)
3/4" NPT(2 PLCS.)
� 10"(254 mm)
CAT. IV VENT(*REFER TO IOM FOR
CAT. II VENT)
9 3/4(248 mm)
46 13/16(1189 mm)
23 3/8(594 mm)
28 5/8(727 mm)
44 9/16(1132 mm)
30 5/8(778 mm)
CENTER OFGRAVITY
POWERSERVICEBOX
� 4"(102 mm)
INLET
� 4"(102 mm)OUTLET
4"ASME FLANGE
� 12"(305 mm)
CAT. I VENT
45 29/32(1166 mm)
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 10.5* @ 230V
Input BTU/hr. 4,000,000 / 1,172 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 3,480,000 / 1,020 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, NEU, GND) Operating Weight 1,535 lbs. / 697 kgs
208-240 VAC / 1PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body Dungs MBC 4000 High Limit (Manual Reset) Jumo
Firing Valve Honeywell B200T1066 2" High Limit (Auto Reset) Jumo
Main Ball Valve 2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25M Blower Motor American Fan 3 HP - FLA 8
Ignition Control Honeywell RM7895C Relief Valve - MB 1-1/2" x 2" set @ 50 psi
Operating Control HeatNet® Relief Valve - MW 1" x 1" set @ 125 psi
Flow Switch ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 435.0 Sq Ft / 40.41 Sq M Design Data Max. 160 psig & 250°F
Water Volume 14.0 gal / 53.00 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
278.4† 17.6† 17.30 51.0 232.0 14.6 12.00 35.4 198.9 12.5 10.48 30.9
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
10168 38435 6779 25624 5084 19218 4067 15374 3389 12812 2905 10982
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
RSUB-86 REV H
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
FUTERA XLF 4000
OUTDOOR UNIT 54 7/8[1394 mm]
35 1/2[902 mm]
24[610 mm]
14 3/4[374 mm]
30 1/2[775 mm]
70 3/8[1788 mm]
CENTER OFGRAVITY
18 11/16[475 mm]
37 7/8[962 mm]
42 7/8[1089 mm]
53 7/8[1368 mm]
36 1/4[921 mm]
41 13/16[1061 mm]
62 7/8[1598 mm]
46 13/16[1189 mm]
CENTER OFGRAVITY
4 3/16[107 mm]
14 9/16[369 mm]
15 1/16[382 mm]
28 9/16[725 mm]
77 1/8[1959 mm]
� 4[102 mm]
ASME FLANGEINLET
9 5/8[245 mm]
19 7/16[493 mm]
� 10[255 mm]
EXHAUST FLUE
� 4[102 mm]
ASME FLANGEOUTLET
FRONT VIEWSIDE VIEW
BACK VIEW
TOP VIEW
29 5/8[752 mm]
1[25 mm]
RSUB-139 REV D
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 5000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-5000-4
LEFT VIEW
FRONT VIEW
TOP VIEW
REAR VIEWBOTTOM VIEW
14 21/32(371mm)
CENTER OFGRAVITY
29 1/8(740mm)
78"(1981mm)
24(610mm)
24 5/8(594mm)
28 5/8(727mm)
44 9/16(1132mm)
39"(991mm)
CENTER OFGRAVITY
35 5/8(905mm)
36"(914mm)
41 1/8(1045mm) 43 11/16
(1111mm)
2" NG & 1 ½" LPNPT GAS TRAIN
4 1/2(114mm) 7 1/8
(181mm)
15"(381mm)
POWERSERVICEBOX
9 3/4(248mm)
� 4"(102mm)
INLET
� 4"(102mm)OUTLET
3/4" NPT(2 PLCS.)
55 13/16(1418mm)
4"ASME FLANGE
22 3/4(575mm)
CENTER OFGRAVITY
31 1/8(791mm)
37 13/16(960mm)
49 3/4(1264mm)
� 1/2(13mm)
(4 PLCS.)
34 1/2(879mm)
3/4(19mm)
2 1/2(63mm)
24"(610mm)
42 7/8(1089mm)
8 1/2(216mm) � 12"
(305mm)
� 12"(305mm)
CAT. IV VENT(*REFER TO IOM FOR CAT. II VENT)
69"(1753mm)
45 29/32(1166 mm)
� 14"(356mm)
CAT. I VENT
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 9.5* @ 230V
Input BTU/hr. 5,000,000 / 1,465 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 4,255,000 / 1,247 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, L3, GND) Operating Weight 1,684 lbs. / 765 kgs
230 VAC / 3 ph / 60 hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body Dungs MBC 4000 High Limit (Manual Reset) Jumo
Firing Valve Honeywell B200T1066 2" High Limit (Auto Reset) Jumo
Main Ball Valve 2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25M Blower Motor American Fan 5 HP - FLA 9
Ignition Control Honeywell RM7895C Relief Valve - MB 1-1/2" x 2" set @ 50 psi
Operating Control HeatNet® Relief Valve - MW 1" x 1" set @ 125 psi
Flow Switch ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 544.3 Sq Ft / 50.56 Sq M Design Data Max. 160 psig & 250˚F
Water Volume 15.6 gal / 59.12 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP†30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
283.7 17.9 21.20 62.5 243.1 15.3 19.70 58.0
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
WATER HEATER HOURLY RECOVERY PENDING
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
RSUB-149 REV C
† Cupronickel heat exchanger standard.
FUTERA XLF 5000
OUTDOOR UNIT
24[610 mm]
15 1/8[384 mm]
38[965 mm]
79 7/16[2017 mm]
CENTER OFGRAVITY
37 1/2[952 mm]
22 1/8[562 mm]
37 7/8[962 mm]
42 7/8[1089 mm]
53 7/8[1368 mm]
54 7/8[1394 mm]
36 3/8[925 mm]
38 3/16[970 mm]
41 15/16[1065 mm]
63 1/8[1603 mm]
CENTER OFGRAVITY
4 9/16[116 mm]
14 9/16[369 mm]
15 1/16[383 mm]
28 9/16[725 mm]
101 1/4[2572 mm]
� 4[102 mm]
ASME FLANGEINLET
� 4[102 mm]
ASME FLANGEOUTLET
� 12[306 mm]
EXHAUST FLUE
9 5/8[245 mm]
19 7/16[493 mm]
55 13/16[1418 mm]
FRONT VIEWSIDE VIEW
BACK VIEW
TOP VIEW
29 5/8[752 mm]
1[25 mm]
RSUB-150 REV C
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 6000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-6000-1R
NOTES:
1. SYMBOL INDICATES CENTER OF GRAVITY.
2. DIMENSIONS ARE NOMINAL AND SUBJECT TOMANUFACTURING VARIATION AND SHOULD NOT BE USED FOR"ROUGHING IN".
3. ALL DIMENSIONS ARE IN INCHES [mm].
VIEW IN DIRECTION ABOTTOM VIEW
TOP VIEW FRONT VIEWLEFT VIEW
VIEW IN DIRECTION BROTATED 180° CLOCKWISE
BACK VIEW
Ø1/2[13]
4X
53 7/8[1368]
26 1/16[662]
2 1/2[64]
18 1/16[459]
26 21/32[677]
59 5/16[1507]
49 1/16[1247]
55 11/32[1406]
59 15/16[1522]
27 23/32[704]
31 1/16[789]
48 15/32[1231] 45 7/32
[1148]
53 31/32[1371]
68 3/8[1737]
12 9/32[312]
2X 4 1/2[114]
2X
51 3/16[1300]
Ø12AIR INTAKE
17 3/16[436]
7 1/8[181]
4X
16 1/16[408]
4X 3/4 NPTDRAIN
Ø12FLUE OUTLET
9 21/32[245]
9 21/32[245]
37 13/16[960]
4" ANSI FLANGEWATER OUTLET
4" ANSI FLANGEWATER INLET
56 5/16[1430]
2 1/2 NPTGAS INLET
42 19/32[1082]
CENTER OFGRAVITY
CENTER OFGRAVITY
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 16.9* @ 230V
Input BTU/hr. 6,000,000 / 1758 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 5,244,000 / 1537 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, L3, GND) Operating Weight 2958 lbs / 1342 kgs
230 VAC / 3PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body (2) Dungs MBC 2500 High Limit (Manual Reset) Jumo
Firing Valve (2) Honeywell B200T1066 1-1/2" High Limit (Auto Reset) Jumo
Main Ball Valve 2-1/2" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25m Blower Motor (2) American Fan 3 HP - FLA 8
Ignition Control (2) Honeywell RM7895C Relief Valve - MB (2) 1-1/4" x 1-1/2" set @ 50 psi
Operating Control HeatNet® Flow Switch (2) ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 650.0 Sq. Ft. / 60.38 Sq. M. Design Data Max. 160 psig & 250°F
Water Volume 25.6 gal / 96.9 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
524.6 33.1 13.2 39.6 419.7 26.5 8.5 25.3 349.7 22.1 5.9 17.6 299.8 18.9 4.3 12.9
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.3. All dimensions are in inches (mm).
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
RSUB-158.A
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 8000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-8000-1R
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.3. All dimensions are in inches (mm).
RSUB-160.A
NOTES: 1. SYMBOL INDICATES CENTER OF GRAVITY. 2. DIMENSIONS ARE NOMINAL AND SUBJECT TO MANUFACTURING VARIATION AND SHOULD NOT BE USED FOR "ROUGHING IN". 3. ALL DIMENSIONS ARE IN INCHES [mm].
VIEW IN DIRECTION ABOTTOM VIEW
TOP VIEW
FRONT VIEWLEFT VIEW
VIEW IN DIRECTION BROTATED 180° CLOCKWISE
BACK VIEW
� 1/2[13]
4X 53 7/8[1368]
26 1/16[662]
2 1/2[64]
18 1/4[463]
31 9/16[802]
59 5/16[1507]
49 1/16[1247]
55 11/32[1406]
68 15/16[1751]
27 23/32[704]
31 1/16[789]
48 15/32[1231] 45 7/32
[1148]
53 31/32[1371]
68 3/8[1737]
12 9/32[312]
2X 4 1/2[114]
2X
60 3/16[1528]
6" ANSI FLANGEWATER OUTLET
Ø14AIR INTAKE
9 21/32[245]
17 3/16[436]
9 21/32[245]
7 1/8[181]
4X
15 1/16[383]
4X 3/4 NPTDRAIN
Ø14FLUE OUTLET
46 13/16[1189]
6" ANSI FLANGEWATER INLET
3 NPTGAS INLET
56 1/32[1424]
44 13/16[1138]
CENTER OFGRAVITY
CENTER OFGRAVITY
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 16.9* @ 230V
Input BTU/hr. 8,000,000 / 2345 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 6,824,000 / 2000 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, L3, GND) Operating Weight 3388 lbs / 1537 kgs
230 VAC / 3PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body (2) Dungs MBC 4000 High Limit (Manual Reset) Jumo
Firing Valve (2) Honeywell B200T1066 2" High Limit (Auto Reset) Jumo
Main Ball Valve 3" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25m Blower Motor (2) American Fan 3 HP - FLA 8
Ignition Control (2) Honeywell RM7895C Relief Valve - MB (2) 1-1/2" x 2" set @ 50 psi
Operating Control HeatNet® Flow Switch (2) ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 870.0 Sq Ft / 80.82 Sq M Design Data Max. 160 psig & 250°F
Water Volume 28.0 gal / 106.00 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
546.1† 34.5† 28.6 85.6 455.1 28.7 19.9 59.5 390.1 24.6 14.6 43.7
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
INDOOR UNIT
FUTERA XLF 10000Category I, II or IV Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 568-9571
SFTIII-10000-1R
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.3. All dimensions are in inches (mm).
RSUB-162.A
NOTES:
1. SYMBOL INDICATES CENTER OF GRAVITY.
2. DIMENSIONS ARE NOMINAL AND SUBJECT TOMANUFACTURING VARIATION AND SHOULD NOT BE USED FOR"ROUGHING IN".
3. ALL DIMENSIONS ARE IN INCHES [mm].
VIEW IN DIRECTION ABOTTOM VIEW
TOP VIEWFRONT VIEWLEFT VIEW
VIEW IN DIRECTION BROTATED 180° CLOCKWISE
BACK VIEW
� 1/2[13]
4X [1368]
26 1/16[662]
2 1/2[64]
20 13/16[528]
41 17/32[1055]
49 1/16[1247]
59 5/16[1507]
55 11/32[1406]
77 15/16[1979]
27 23/32[704]
31 1/16[789]
48 15/32[1231]
45 1/4[1149]
53 31/32[1371]
68 3/8[1737]
12 9/32[312]
2X 4 1/2[114]
2X
69 3/16[1757]
6" ANSI FLANGEWATER OUTLET
9 21/32[245]
17 3/16[436]
9 21/32[245]
7 1/8[181]
4X
15 1/16[383]
4X 3/4 NPTDRAIN
Ø16FLUE OUTLET
55 13/16[1418]
6" ANSI FLANGEWATER INLET
3 NPTGAS INLET
56 1/32[1424]
Ø18AIR INTAKE
53 13/16[1367]
CENTER OFGRAVITY
CENTER OFGRAVITY
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 26.9* @ 230V
Input BTU/hr. 10,000,000 / 2931 kW Min. Gas Pressure Required 3.5" WC**
Output BTU/hr. 8,510,000 / 2494 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements (L1, L2, L3, GND) Operating Weight 3641 lbs / 1652 kgs
230 VAC / 3PH / 60Hz
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Body (2) Dungs MBC 4000 High Limit (Manual Reset) Jumo
Firing Valve (2) Honeywell B200T1066 2" High Limit (Auto Reset) Jumo
Main Ball Valve 3" Blocked Flue Switch HUBA
Manual Pilot Valve 1/4" Honeywell B528 Air Switch HUBA
Pilot Regulator White-Rodgers 25m Blower Motor (2) American Fan 5 HP - FLA 9
Ignition Control (2) Honeywell RM7895C Relief Valve - MB (2) 1-1/2" x 2" set @ 50 psi
Operating Control HeatNet® Flow Switch (2) ITT FS8W
A.S.M.E.ASME Sect IV Htg Surface 1088.6 Sq Ft / 101.1 Sq M Design Data Max. 160 psig & 250°F
Water Volume 31.2 gal / 118.24 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP†30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
567.6 35.8 33.0 98.7 486.5 30.7 24.3 72.5
* Add circulator amps.** For incoming gas pressures lower than 3.5" W.C. natural or propane, consult factory.
† Cupronickel heat exchanger standard.