6
Increase patient comfort and therapeutic benefits Dedicated accessories for Carina® ventilator CARINA® MT-0567-2008

Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

Increase patient comfort and therapeutic benefitsDedicated accessories for Carina® ventilator

CARINA®

MT-

0567

-200

8

Page 2: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

4 |

Flexible and compact NIV ventilator: Carina®

The road to recovery Non-invasive ventilation (NIV) in general can helppatients to recover faster, reduce the rate ofventilator associated pneumonia and avoid thesetback of reintubation in a variety of clinicalsettings. Patient benefit has been clearlydemonstrated in a growing number of studies1.

– Reduce the need for intubation and therapeuticintervention in patients with acute respiratoryfailure2

– Decrease the rate of intubation3

– Fewer complications during ICU stay2

– Reduce the risk of ventilator associatedpneumonia4

1 Burns KEA, Adhikari NKJ, Meade MO: Noninvasive positive pressure ventilation as a weaning strategy for intubated adults with respiratory failure. Cochrane Database of Systematic Reviews 2003.

2 Honrubia T, López FJG, Franco N, et al.: Noninvasive vs. conventional mechanical ventilation in acute respiratory failure: A multicenter randomized controlled trial. Chest 2005; 128:3916-3924.

3 Masip J, Roque M, Sánchez B, et al. Noninvasive ventilation in acute cardiogenic pulmonary edema: systematic review and meta-analysis. JAMA. 2005;294:3124-31304 Girou E, Schortgen F, Delclaux C, et al. Association of noninvasive ventilation with nosocomial infections and survival in critically ill patients. JAMA 2000; 284:2361–2367

Dräger has developed an innovative type of highperformance NIV ventilator. One that is comfortable for both the patient and thecaregiver, compact and mobile enough to optimizeworkflow and workspace usage and clever enoughto recognize changes in flow parameters andpatient status, providing just the right amount ofsupport while giving the patient room to breathe.

The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes forspontaneous and mandatory ventilation. In addition, the Carina can even be used forinvasive ventilation should the need arise, allowingthe caregiver maximum flexibility.

MT-

2802

-200

8

MT-

8221

-200

5

Page 3: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

05 |

Carina® non-invasive accessories

Dedicated accessories support the selectedventilation mode and allow the caregiver to use thedevice according to different applications andpatient profiles:

Leaks are a common challenge in non-invasiveventilation. Rapid recognition of leaks can mean the difference between success and setback.The unique Dräger SyncPlus functionalityaddresses this challenge by offering:

– Automatic leakage compensation– Cycle learning technology: the trigger sensitivity

is constantly adapted to the patient’s breathingpatterns

– Multi-sense triggering by closely analyzing flow,pressures and flow gradient

DEDICATED BREATHING CIRCUIT

For non-invasive ventilation it is recommended touse the leakage valve breathing system. This convenient disposable single-hose breathingsystem allows the accurate calculation andadjustment of volumes. Due to its patented designthe Dräger breathing system VentStar LeakVoptimally supports the leakage compensationcapabilities of the Carina. In addition, the design of the leak valve preventsthe breathing circuit from twisting which avoidsocclusion and insufficient ventilation of the patient.

NON-INVASIVE MASKS

The Carina breathing system is completed by theDräger non-invasive ventilation full-face masks:ClassicStar and NovaStar. Because both maskscover the nose and mouth, they provide an effectivetherapy even in case of mouth breathing.

The two major challenges in terms of non-invasivepatient interfaces are maximize patient comfort andminimize leakages. The air-filled mask cushion of the ClassicStar SENIV mask can be adjusted to the patient’s facialcontours by inflating or deflating the mask cushionwhich increases comfort and makes a moreeffective seal. The NovaStar SE NIV mask providesan individual –”customized”– fit due to theembedded pliable ring in the flexible, transparent,soft mask shell combined with a silicone gel maskcushion for premium comfort and seal. Additionalfeatures, which include the individual adjustableforehead support and lightweight rapid fixationhead gear, emphasize the convenience of both NIVmasks.

The ClassicStar NIV masks are designed for singleuse. The NovaStar NIV masks can be cleaned andre-used maximum five times.

Page 4: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

MT-

0583

-200

7

NovaStar®

MT-

0581

-200

7

ClassicStar®M

T-43

87-2

007

Filter CareStar®

| 06

Dedicated accessoriesfor different

applications

INVASIVE VENTILATION

In case of changes in the patient constitution the Carina can be used for invasive ventilation. For this kind of application the VentStar CarinaExpV breathing system should be used. It is alsorecommended for the use in situations whereoxygen consumption could be critical. Providing a maximum pressure of 50 mbar the VentStarCarina ExpV should be used in patient profiles in which a higher pressure is essential.

MT-

9634

-200

6

MT-

9633

-200

6

VentStar™ Carina® LeakV

MT-

1992

-200

8

SyncVent for Carina®VentStar™ Carina® ExpV

Dedicated accessories for non-invasive ventilation results in moreconsistent flow, increased patient comfort and superior therapeuticbenefits:– Patient comfort even in case of leaks or changing

ventilation patterns – Can reduce the work of breathing – Can reduce ventilation settings for caregivers– Complete system solution for non-invasive ventilation therapy

mankew
Eingefügter Text
needs of changes in
Page 5: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

1 |

comfortable for both the patient and the

caregiver ORDER INFORMATION

Carina With country specific gas connector and main cable 8419350

NovaStar SE, size L Full-face mask for non-invasive ventilation MP01581NovaStar SE, size M Full-face mask for non-invasive ventilation MP01580NovaStar SE, size S Full-face mask for non-invasive ventilation MP01579

ClassicStar SE, size L Non-invasive ventilation mask with Standard Elbow MP01575ClassicStar SE, size M Non-invasive ventilation mask with Standard Elbow MP01574ClassicStar SE, size S Non-invasive ventilaiton mask with Standard Elbow MP01573Two-sided pump ball For air management MP01590

VentStar Carina LeakV Disposable Leak valve breathing system consisting MP00312of leak valve, pilot line and hose; (5 pcs.)

VentStar Carina ExpV Disposable Expiratory valve breathing system consisting MP00313of expiration valve and hose, (5 pcs.)

SyncVent Carina Leak valve single item; without hose (set of 5 pcs.) MP00224Expiratory valve Expiratory valve single item; without hose (1 pc.) MP00220

Filter CareStar 30 Breathing system filter

Trolley 1-78 cm Height of screen 105 cm, 78 cm height of backbone, total height 88 cm G93038Trolley 1-63 cm Height of screen 90 cm, 63 cm height of backbone, total height 73 cm G93037

Quick stop hinged arm 3 hose clamps (single), 3 hose clamps (double) 2M85705Connecting hose holder Cable winder 2M85446Universal holder with standard rail Rail for humidifier G93140F&P Humidifiers and accessories Humidifier and reusable and disposable accessories 8414144HEPA filter Inlet filter for Carina 5703105

Ext. battery pack EU European standard 5704668Ext. battery pack UK British - BS 1363 Standard 5704669Ext. battery pack US USA - NEMA 5-15P standard 5704670Ext. battery pack AUS Australian - AS3112 standard 5704671Ext. battery pack CN Chinese - GB1002 standard 5704672Battery Holder Metal box on trolley G93150

Test lung, blue 8403201Test lung, white 8401892

O2 monitor MiniOx 2M22464 O2 MiniOx Sensor 2M22461 MiniOx rail holder 2M22460 Aeroneb Pro nebuliser set MP01010

Page 6: Increase patient comfort CARINA® and therapeutic benefits ... .pdf · The Carina provides high-performance non-invasive ventilation therapy. It features a range of ventilation modes

90 5

1 92

1 |

05.0

9-1

| M

arke

ting

Com

mun

icat

ions

| C

R |

PR

| E

D |

Prin

ted

in G

erm

any

| C

hlor

ine-

free

–en

viro

nmen

tally

com

patib

le|

Sub

ject

to m

odifi

catio

ns|

© 2

009

Drä

ger

Med

ical

AG

& C

o. K

G

Manufacturer:Dräger Medical AG & Co. KG23542 Lübeck, GermanyThe quality management system atDräger Medical AG & Co. KG is certified according to ISO 13485, ISO 9001 and Annex II.3 of Directive93/42/EEC (Medical devices).

HEADQUARTERSDräger Medical AG & Co. KGMoislinger Allee 53–5523558 Lübeck, Germany

www.draeger.com

REGION EUROPE CENTRAL AND EUROPE NORTHDräger Medical AG & Co. KGMoislinger Allee 53–5523558 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]

REGION EUROPE SOUTHDräger Médical S.A.S. Parc de Haute Technologie d’Antony 225, rue Georges Besse92182 Antony CedexTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]

REGION MIDDLE EAST, AFRICA, CENTRAL AND SOUTH AMERICADräger Medical AG & Co. KGDubai Healthcare CityP.O. Box 505108Dubai, United Arab EmiratesTel +971 436 24 762Fax +971 436 24 761

REGION ASIA / PACIFICDraeger Medical South East Asia Pte Ltd25 International Business Park#04-27/29 German CentreSingapore 609916Tel +65 6572 4388Fax +65 6572 4399 [email protected]

REGION NORTH AMERICADraeger Medical, Inc.3135 Quarry Road Telford, PA 18969, USATel +1 215 721 5400Toll-free +1 800 437 24 37Fax +1 215 723 59 [email protected]