112
Since 1987 IMPLANTS DIFFUSION INTERNATIONAL 2015 PRODUCT CATALOG

IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

2015 PRODUCT CATALOG

Page 2: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

2 www.idisystem.eu

TABLE OF CONTENTS /

06

MORSE TAPER CONNECTION

IDBIO® Range Presentation .............................................. 08 IDBIO® surgical protocol ...................... 10 Ø3,5 IDBIO® Implant ................................ 11 Fixed prosthesis Removable prosthesis Ø4 IDBIO® Implant ..................................... 15 Fixed prosthesis Removable prosthesis Ø5 IDBIO® Implant ...................................... 19 Fixed prosthesis Removable prosthesis

IDMAX® Range Presentation .............................................. 26 IDMAX® surgical protocol ..................... 28 Ø4,4 IDMAX® Implant ................................ 29 Fixed prosthesis Removable prosthesis Ø5 IDMAX® Implant ................................... 33 Fixed prosthesis Removable prosthesis Ø6,6 IDMAX® Implant ............................... 37 Fixed prosthesis Removable prosthesis

IDOT Range Presentation .............................................. 44 IDOT surgical protocol .......................... 46 Ø4,4 IDOT Implant .................................... 47 Fixed prosthesis Removable prosthesis Ø5 IDOT Implant ........................................ 51 Fixed prosthesis Removable prosthesis

IDALL® Range Presentation .............................................. 58 IDALL® surgical protocol ...................... 60 Ø4,2 IDALL® Implant ................................ 61 Fixed prosthesis Removable prosthesis Drill set for IDALL® implants ................. 66 Ø5,2 IDALL® Implant ................................ 67 Fixed prosthesis Removable prosthesis

IDCAM® Range Why changing for IDCAM® ? ............. 74 Presentation of the IDCAM® S ........... 76 Presentation of the IDCAM® M ......... 78 IDCAM® surgical protocol ..................... 80 IDCAM® S and M implants ..................... 81 Prosthetic approach ........................... 82 Fixed prosthesis Removable prosthesis

IMPLANT RANGE & Prosthetic Systems

07

25

43

57

73

Page 3: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 3

PRESENTATION

04 IDI, since 1987 05 Our Quality commitment24 IDI globally42 The sales team56 The Research & Development department72 The IDI communication

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

FOCUS ON PROSTHETICS Zirconia ......................................................... 23 Transgingival Titan kits ........................ 41 IDLoc .............................................................. 55 IDUnit .............................................................. 90 General prosthetic approach ........ 91

RBS® SURGICAL SETS IDCAM/BIO .......................................................... 94 The RBS® C tapered drills RBS® ................................................................. 96 The RBS® cylindrical drills

OSTEOSINUS Osteosinus set ........................................... 101 Osteosinus .................................................... 102 Rectisinus ...................................................... 102 Angulosinus ................................................. 103 Forsinus ........................................................... 103 Trepanosinus .............................................. 104 Diskosinus ...................................................... 104 Procedure for Trepanosinus ............ 105 Procedure for Forsinus ........................ 107

ACCESSORIES AND RELATING INSTRUMENTS Ridge spreading condensing ......... 108 Trephines ...................................................... 108 Ratchets ........................................................ 109 Thread tap .................................................. 109 Screwdrivers ............................................... 109 Instruments .................................................. 109

Packaging of IDI implants ..................... 110

Read more about our General terms and conditions of sale on our website: www.idisystem.eu

93

99

108

Products featured in our catalog are medical devices restricted to health professionals.

Page 4: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Since 1987SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

“WE DEVELOP AND MANUFACTURE IN FRANCE”

Since 25 years, IDI firm (Implants Diffusion International), in collaboration with a team of researchers, engineers and dental surgeons, has regularly developped new products intended to implantology.

Implants Diffusion International invests a great deal in the research of new technologies such as RBS® drill, state of surface SMA +Tio2,

Osteosinus…

The IDI lines are developed and manufactured in the Paris region, France by professionals fully com-mitted to meet the practitioners expectations. IDI applies a strict Quality policy to each manufac-turing step. The IDI company is certified according to the applicable standards: ISO 13485, ISO 9001,

CE, TCP, FDA, CMDCAS by SGS.

The IDBIO® range was successfully launched in 2011 and was quickly appreciated by practitioners all over

the world.

The next decade will see the launching of numerous innova-tions emerging from our Research and Development Department.

Gérard Boukhris - President

SCC AccreditedCB

TaiwanTaiwanT

4 www.idisystem.eu

Page 5: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

The IDI teams, concerned with the trust relationship that they enter into with the practitioners, decided to offer lifetime warranties to all the implant lines of the IDI brand.

Proud of our implant quality, we supply an accurate customer service to assist you in your daily practice in order to meet your highest requirements. The “General conditions” and the warranty protocol may be downloaded from the www.idisystem.fr website, section: Documentations/Quality.IDI put the customer relationship at the heart of its concerns every day. The IDI teams are regularly trained in the latest cutting-edge techniques and in all the products necessary to the implantologists.

Our product Quality is a key asset to a stress-free practice.

THE QUALITY COMMITMENT OF THE IDI COMPANY / THE LIFETIME WARRANTY

IDI IMPLANTS DIFFUSION INTERNATIONAL 5

Important considerations about IDI SystemTightening torques

PRODUCTS Values(Ncm)

Comments

Implants ≤75 Use the ratchetClosing cap 5 to 10

Use the manual screwdriver*

Healing cap 5 to 10IDUnit : abutment 25IDUnit : retaining screw 15Retaining screw 25Manual screwdriver 5 to 25Screwdriver with dental shank 25 Use the contra angle or the torque wrench*

* Distortion of the screwdriver at 45Ncm to preserve the implant.

!

IDI - Implants Diffusion International - develops, manufactures and distributes the largest range of dental implants all over the world, as well as implantology and dental surgery equipment. IDI products are manufactured in France exclusively. They’re resulting from the essential work of the Research and Development Department. For IDI, to be close to practitioners, hospitals and implantology training centres is a great deal, because they take part to the constant innovation.

Page 6: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Implant range and prosthetic systems

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

HEXAGONAL CONNECTION /

IDBIO®

IDMAX®

IDOT

MORSE TAPER CONNECTION /

IDALL®

IDCAM®

SURGICAL SETS

PACKAGING OF IDI IMPLANTS

07

57

93110

6

Page 7: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IDBIO® / Range

“The profile of the IDBIO® implant is inspiring numerous brands. The association between this profile and a stabilized internal hexagonal connection gives me entire satisfaction.”

Dr Justine B. (Belgium)

7

Page 8: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

8 www.idisystem.eu

Range IDBIO® /PRESENTATIONThe internal conception of the IDBIO® implant significantly improves the stabilization of the prosthetic reconstructions thanks to its GSP® connection (Groove for Prosthetic Stabilization).

The IDBIO® benefits from the S.M.A sandblasted, acid-etched and TiO2 coated state of surface, from a two-phase Ti6Al4V grade 5.The IDBIO® implant draws special attention to itself thanks to its square and V shaped threads and thanks to its anchorage for prosthetic stabilization.This self-condensing implant stands 75 N.cm screwing stress without being affected.

This implant draws special attention to itself due to its hexagonal prosthetic anchorage and its cylindro-tapered shape like a dental root. Its cylindrical shape at the level of the implant neck reduces the tension at the level of the crestal bone. Its conical shape allows a better insertion between the adjacent teeth. The angulation, the space and the depth of the threads were specially studied to optimize the stabilization in any bone density and favor the immediate loading.Its aggressive apex enables efficient primary catch.

Self-drillinglow threads

Condensinghigh threads

Anti-unscrewinggroove

Anchorage compatible with IDI

Anchorage of prosthetic stabilization

Hexagonal prosthetic anchorage

Internal universal ISO thread

Instructions for use:1. Use the screwdriver P/N 0146,

1046, 0046, 0846 to screw the implant.

2. Use the screwdriver P/N 0014, 1014, 1114, 0114 to screw the cover screw manually at 5 N.cm while omitting the hinged ratchet.

Features of the IDBIO® implant:– Cylindro-tapered-shaped

– Titanium alloy two phase Ti6Al4V grade 5

– S.M.A. TiO2 state of surface

– Hexagonal connection

– Anti-unscrewing groove

– Progressive and condensing threads

– Penetrating apex

Page 9: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 9

IDB

IO®

Non

con

tract

ual p

ictu

res

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

HEXAGONAL CONNECTION

THE

IMPL

AN

TS

LIN

ES

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

IDB 0835

IDB 0840

IDB 0850

IDB 1035

IDB 1040

IDB 1050

IDB 1235

IDB 1240

IDB 1250

IDB 1535

IDB 1540

IDB 1550

IDBIO® IMPLANT RANGEIMPLANT TYPE LENGTH P/N

All the dimensions are in millimeters.

Color code

8

8

10

10

10

12

12

12

15

15

15

8

IDBIO® 3,5

IDBIO® 4

IDBIO® 5

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:

8 mm length10 mm length12 mm length15 mm lengthLE

NG

TH 1

0LE

NG

TH 8

LEN

GTH

12

LEN

GTH

15

Page 10: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

10 www.idisystem.eu

EXAMPLE OF AN IDBIO® IMPLANT - FOR THE MANDIBULE (example with the implant placement for an IDBIO® implant P/N: IDB1240)

Important considerations about IDBIO®

The Ø 3,5mm IDBIO® implants are reserved for the upper lateral incisors and lower incisors only.

The IDBIO® implants are supplied with a sterile closing cap and a healing cap.To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.

It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.

The length choice and implant diameter must be based on the bone density determined by the CT-scan.

!

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

Ø 3,5 mm

Ø 4 mm

Ø 5 mm

IDB 0835

IDB 0840

IDB 0850

LENGTHDRILL TO US

IDBIO® IMPLANT P/N

Color code*

IDB 1035

IDB 1040

IDB 1050

IDB 1235

IDB 1240

IDB 1250

IDB 1535

IDB 1540

IDB 1550

All the dimensions are in millimeters.

8

8

10

10

10

12

12

12

15

15

15

8

Suture.

Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.

Screw the implant P/N IDB1240:• with the help of a contra-angled handpiece and a screwdriver P/N.:1046 or 1146;• or with the manual screwdriver P/N: 0846.

Finish screwing the paracrestal implant with the screwdriver P/N.:1146 or 1046 and the ratchet P/N.:414

Use the pilot drill P/N.: 1220 of 2mm diameter & 12mm length. Drill at 350 rpm with ample cooling.

Screw the cover screw at 5N.cm with the screwdriver P/N.: 0014 or 0114

Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.

5 6

3

4

21

IDBIO®

SURGICAL PROTOCOL

(Omit this step for an implant placement at the maxilla.)

Page 11: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 11

IDB

IO®

Non

con

tract

ual p

ictu

res

Ø 3,

5 MM

3,53,5 Ø 3,5 MM IDBIO® EMERGENCE

Ø3,5 IDBIO® Implants

Length 8 mm - Diameter 3,5 mm IDB 0835

Length 10 mm - Diameter 3,5 mm IDB 1035

Length 12 mm - Diameter 3,5 mm IDB 1235

Length 15 mm - Diameter 3,5 mm IDB 1535

Closing cap

Ø 3,5mm closing cap 1231

Healing cap

Ø 3,5mm IDBIO® healing cap – 2 mm high 1330

Ø 3,5mm IDBIO® healing cap – 4 mm high 1331

Ø 3,5mm IDBIO® healing cap – 6 mm high 1332

Page 12: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

12 www.idisystem.eu

Prosthetic components

Ø 3,5 MM EMERGENCE

FIXED PROSTHESIS

Burnout cylinders

Non rotational, incl. retaining screw P/N 1414 356S

Rotational, incl. retaining screw P/N 1414 358S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6350H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6350R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6351H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6351R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6352H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6352R

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH35

Cylinder, gold, rotational to cast on + screw ASR35

Zirconia TiBase

Titan abutment basis + screw 7535

Titan abutments for a temporary toothNon rotational Ø 3,5mm Incl. screw APPH35

Rotational Ø 3,5mm Incl. screw APPR35

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutmentsStraight Slim abutment for Platform switch + retaining screw P/N 0215

3400G

Abutment, straight + retaining screw P/N 0215 3600G

Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 3602G

Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 3604G

Abutment, 15° angled + retaining screw P/N 0215 3615G

Abutment, 23° angled + retaining screw P/N 0215 3623G

Ø 3,5mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU1G

Implant analog

For Ø 3,5mm IDBIO® implant 2335

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

For prosthesis, short head: ≤ 25N.cm maximum 1413

Page 13: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 13

IDB

IO®

Non

con

tract

ual p

ictu

res

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

HEXAGONAL CONNECTION

Ø 3,

5 MM

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U3501

IDUnit attachment, Transgingival height: 2,5 mm U3502

IDUnit attachment, Transgingival height: 4 mm U3504

IDUnit attachment, Transgingival height: 6 mm U3506

17° angled IDUnit attachment (1 mm high) U3521

30° angled IDUnit attachment (1 mm high) U3531

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 00216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Page 14: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

14 www.idisystem.eu

Prosthetic components

Ø 3,5 MM EMERGENCE

IDLoc

IDLoc attachments Transgingival height: 1 mm L3501

Transgingival height: 2,5 mm L3502

Transgingival height: 4 mm L3504

Transgingival height: 6 mm L3506

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222351

Transgingival height: 2,5 mm 222352

Transgingival height: 4 mm 222354

Transgingival height: 6 mm 222356

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 935

Magnetic 0940

REMOVABLE PROSTHESIS

Page 15: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL

IDB

IO®

Non

con

tract

ual p

ictu

res

15

Ø 4

MM

44 Ø 4 MM IDBIO® EMERGENCE

Ø4 IDBIO® Implants

Length: 8mm – Diameter 4,0mm IDB 0840

Length: 10mm – Diameter 4,0mm IDB 1040

Length: 12mm – Diameter 4,0mm IDB 1240

Length: 15mm – Diameter 4,0mm IDB 1540

Closing cap

Ø 4mm IDBIO® closing cap 1241

Healing cap

Ø 4mm IDBIO® healing cap; height: 2mm 1340

Ø 4mm IDBIO® healing cap; height: 4mm 1341

Ø 4mm IDBIO® healing cap; height: 6mm 1342

Page 16: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

16 www.idisystem.eu

Prosthetic components

Ø 4 MM EMERGENCE

FIXED PROSTHESIS

Burnout cylinders

Non rotational, incl. retaining screw P/N 1414 456S

Rotational, incl. retaining screw P/N 1414 458S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6400H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6400R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6401H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6401R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6402H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6402R

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH40

Cylinder, gold, rotational to cast on + screw ASR40

Zirconia TiBase

Titan abutment basis + screw 7540

Titan abutments for a temporary toothNon rotational Ø 4mm Incl. screw APPH40

Rotational Ø 4mm Incl. screw APPR40

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Slim abutment for Platform switch + retaining screw P/N 0215 3800G

Abutment, straight + retaining screw P/N 0215 4000G

Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 4002G

Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 4004G

Abutment, 15° angled + retaining screw P/N 0215 4015G

Abutment, 23° angled + retaining screw P/N 0215 4023G

Ø 4mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU2G

Implant analog

For Ø 4mm IDBIO® implant 2340

Retaining screwsGolden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

For prosthesis, short head: ≤ 25N.cm maximum 1413

Page 17: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 17

IDB

IO®

Non

con

tract

ual p

ictu

res

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

HEXAGONAL CONNECTION

Ø 4

MM

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4001

IDUnit attachment, Transgingival height: 2,5 mm U4002

IDUnit attachment, Transgingival height: 4 mm U4004

IDUnit attachment, Transgingival height: 6 mm U4006

17° angled IDUnit attachment (1 mm high) U4021

30° angled IDUnit attachment (1 mm high) U4031

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Page 18: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

18 www.idisystem.eu

Prosthetic components

Ø 4 MM EMERGENCE

IDLoc

IDLoc attachments Transgingival height: 1 mm L4001

Transgingival height: 2,5 mm L4002

Transgingival height: 4 mm L4004

Transgingival height: 6 mm L4006

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222401

Transgingival height: 2,5 mm 222402

Transgingival height: 4 mm 222404

Transgingival height: 6 mm 222406

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 941

Magnetic 0940

REMOVABLE PROSTHESIS

Page 19: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL

IDB

IO®

Non

con

tract

ual p

ictu

res

19

Ø 5

MMØ 5 MM

IDBIO® EMERGENCE

Implants IDBIO® Ø5

Length: 8mm – Diameter 5,0mm IDB 0850

Length: 10mm – Diameter 5,0mm IDB 1050

Length: 12mm – Diameter 5,0mm IDB 1250

Length: 15mm – Diameter 5,0mm IDB 1550

Closing cap

Ø 5mm IDBIO® closing cap 1251

Healing cap

Ø 5mm IDBIO® healing cap; height: 2mm 1350

Ø 5mm IDBIO® healing cap; height: 4mm 1351

Ø 5mm IDBIO® healing cap; height: 6mm 1352

5

Page 20: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

20 www.idisystem.eu

Prosthetic components

Ø 5 MM EMERGENCE

FIXED PROSTHESIS

Burnout cylinders

Non rotational, incl. retaining screw P/N 1414 556S

Rotational, incl. retaining screw P/N 1414 558S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

For prosthesis, short head: ≤ 25N.cm maximum 1413

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50

Cylinder, gold, rotational to cast on + screw ASR50

Zirconia TiBase

Titan abutment basis + screw 7550

Titan abutments for a temporary toothNon rotational Ø 5mm Incl. screw APPH50

Rotational Ø 5mm Incl. screw APPR50

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Slim abutment for Platform switch + retaining screw P/N 0215 3800G

Abutment, straight + retaining screw P/N 0215 5000G

Abutment, straight, with a 2mm shoulder + retaining screw P/N 0215 5002G

Abutment, straight, with a 4mm shoulder + retaining screw P/N 0215 5004G

Abutment, 15° angled + retaining screw P/N 0215 5015G

Abutment, 23° angled + retaining screw P/N 0215 5023G

Ø 5mm Abutment, 0° to 18° + retaining screw P/N 0215 HTU5G

Implant analog

For Ø 5mm IDBIO® implant 2350

Page 21: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 21

IDB

IO®

Non

con

tract

ual p

ictu

res

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

HEXAGONAL CONNECTION

Ø 5

MM

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001

IDUnit attachment, Transgingival height: 2,5 mm U5002

IDUnit attachment, Transgingival height: 4 mm U5004

IDUnit attachment, Transgingival height: 6 mm U5006

17° angled IDUnit attachment (1 mm high) U5021

30° angled IDUnit attachment (1 mm high) U5031

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Page 22: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

22 www.idisystem.eu

Prosthetic components

Ø 5 MM EMERGENCE

IDLoc

IDLoc attachments Transgingival height: 1 mm L5001

Transgingival height: 2,5 mm L5002

Transgingival height: 4 mm L5004

Transgingival height: 6 mm L5006

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222501

Transgingival height: 2,5 mm 222502

Transgingival height: 4 mm 222504

Transgingival height: 6 mm 222506

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 951

Magnetic 0940

REMOVABLE PROSTHESIS

Page 23: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 23

FOC

US O

N

PRO

STHE

TICS

PROSTHETIC REHABILITATION WITH A ZIRCONIA ABUTMENT

ZIRCONIA ABUTMENT SCREW-RETAINED ON TITAN BASIS

Focus on prosthetics ZIRCONIA

Implant analogImpression copying Zirconia abutment basis + screw

Option for the preparation of a fixed prosthesis.

Screw the zirconia abutment with: • a square-tipped instrument with dental shank P/N 1014 or 1114. • or with the screwdriver P/N 0014 or 0114. Screw up to 25N.cm.

Zirconia abutment Performed by the dental lab

Page 24: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

24

Since 1987, IDI has an exchange with practitioners and implantologists from all over the world. This is a key element taking part in the implant conception by the R&D department.

A COLLABORATION WITH PRACTITIONERS FROM 30 COUNTRIES /

IDI INTERNATIONALLY

Gérard Boukhris and the Export team daily ensure the right coordination of international activity. The purpose is to guarantee the customer a perfect proximity, reactivity, advice and service quality.

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

www.idisystem.eu

guarantee the customer guarantee the customer a perfect proximity, a perfect proximity, reactivity, advice and

Page 25: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

“At the beginning of my activity, I used to work with flared neck cylindro-tapered implants. I tried the IDMAX® implant and I have no regret. Its aesthetic neck allowed me to treat several difficult cases with a low gum height. ”

Dr Marc D. (France)

25

IDMAX® / Range

Page 26: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Range IDMAX® /

26 www.idisystem.eu

Gold-polished aesthetic neck

Penetrating threads

Cylindro-tapered

S.M.A. TiO2 state of surface

Ti6Al4V ELITITANIUM ALLOY

Convex apex

Instructions for use: IDMAX® 41. Last drill in the sequence: diameter

3.5 mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N

1146, 1046, 0146, 0046 to insert the implant.

4. he IDMAX® 4 type implants can be set using the one-step, the one and half step or the two-step technique.

5. With poorly mineralized bone the last drill is only inserted up to a third of its length.

6. Use the manual thread tap P/N TAR4.

IDMAX® 51. Last drill in the sequence: diameter

4 mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N

1146, 1046, 0146, 0046 to insert the implant.

4. The IDMAX® 5 type implants can be set using the one-step, the one and half step or the two-step technique.

5. With poorly mineralized bone the last drill is only inserted up to a third of its length.

6. Use the manual thread tap P/N TAR5.

IDMAX® 61. Last drill in the sequence: diameter 5,4

mm.2. Omit the profile drill stage.3. Use a hexagonal screwdriver P/N

1146, 1046, 0146, 0046 to insert the implant.

4. The IDMAX® 6 type implants can be set using the one-step, the one and half step or the two-step technique.

5. With poorly mineralized bone the last drill is only inserted up to a third of its length.

6. Use the manual thread tap P/N TAR6.

Page 27: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

THE

IMPL

AN

TS

LINES

IDM

AX

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 27

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:

06 mm length08 mm length10 mm length12 mm length15 mm length

Ø 4 mm

Ø 5 mm

Ø 6 mm

Ø 4 mm

Ø 5 mm

Ø 4 mm

Ø 5 mm

Ø 6 mm

Ø 4 mm

Ø 5 mm

Ø 6 mm

Ø 4 mm

Ø 5 mm

Ø 6 mm

IM+ 0840

IM+ 0850

IM+ 0860

IM+ 0640

IM+ 0650

IM+ 1040

IM+ 1050

IM+ 1060

IM+ 1240

IM+ 1250

IM+ 1260

IM+ 1540

IM+ 1550

IM+ 1560

IDMAX® IMPLANT RANGEIMPLANT TYPE LENGTH P/N

All the dimensions are in millimeters.

Color code*

LEN

GTH

8LE

NG

TH 6

LEN

GTH

10

LEN

GTH

12

LEN

GTH

15

8

8

8

10

10

10

12

12

12

15

15

15

6

6

4,44,4 4,94,9 6,66,6

EMERGENCE

Page 28: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

28 www.idisystem.eu

Insert the closing cap into the implant and suture.

The implant is covered with a membrane after six weeks if the gum has attained physiological thickness.

Complete the drilling sequence - omitting the profile drill stage, until the required length and diameter are attained.

Insert the implant so that the gold neck remains exposed supracrestally.

3

4

21

Ø 4,1

R 2

0,8

Ø 4,400,50

Ø 4,6

0,8

Ø 4,900,50

R 2,50

0,8

0,50Ø 6,60

Ø 6

R 4IDMAX® 4

IDMAX® 5

IDMAX® 6

SURGICAL PROTOCOL

EXAMPLE OF AN IDMAX® IMPLANT PLACEMENT

Page 29: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL

IDM

AX

®

29

Ø 4,1

R 2

0,8

Ø 4,400,50

4,44,4

Ø4,4 IDMAX® Implants

Length: 6mm – Diameter 4,4mm IM+ 640

Length: 8mm – Diameter 4,4mm IM+ 840

Length: 10mm – Diameter 4,4mm IM+ 1040

Length: 12mm – Diameter 4,4mm IM+ 1240

Length: 15mm – Diameter 4,4mm IM+ 1540

Closing cap

Ø 4,4mm closing cap 441

Healing cap

Ø 4,4mm cylindrical healing cap; height: 5mm 413

Ø 4,4mm cylindrical healing cap; short head; height: 3,2mm 413C

Ø 4,4mm cylindrical healing cap; long head; height: 6,5mm 413L

Ø 4,4 MM IDMAX® EMERGENCE

Ø 4,

4 M

M

Page 30: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

30 www.idisystem.eu

FIXED PROSTHESIS

Burnout cylinders

Rotational incl. retaining screw P/N 914C 418S

Non rotational incl. retaining screw P/N 914C H426S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH44

Cylinder, gold, rotational to cast on + screw ASR44

Zirconia TiBase

Titan abutment basis + screw 7544

Titan abutments for a temporary toothNon rotational Ø 4,4mm incl. screw P/N 1414 APPH44

Rotational Ø 4,4mm incl. screw P/N 1414 APPR44

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Abutment, 5° angled + retaining screw P/N 0215

AM 4405G

Abutment, 15° angled + retaining screw P/N 0215

AM 4415G

Abutment, 23° angled + retaining screw P/N 0215

AM 4423G

Ø 4mm, 0-18° + retaining screw P/N 0215 HTU4G

Implant analog

For Ø 4,4mm IDMAX® implant 423

Prosthetic components

Ø 4,4 MM EMERGENCE

All the dimensions are in millimeters.

IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)

Page 31: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IDM

AX

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 31

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4401

IDUnit attachment, Transgingival height: 2,5 mm U4402

IDUnit attachment, Transgingival height: 4 mm U4404

IDUnit attachment, Transgingival height: 6 mm U4406

17° angled IDUnit attachment (1 mm high) U4421

30° angled IDUnit attachment (1 mm high) U4431

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw Retaining screw; for prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Ø 4,

4 M

M

Page 32: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

32 www.idisystem.eu

IDLoc

IDLoc attachments Transgingival height: 1 mm L4401

Transgingival height: 2,5 mm L4402

Transgingival height: 4 mm L4404

Transgingival height: 6 mm L4406

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222441

Transgingival height: 2,5 mm 222442

Transgingival height: 4 mm 222444

Transgingival height: 6 mm 222446

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 944

Magnetic 0940

REMOVABLE PROSTHESIS

Prosthetic components

Ø 4,4 MM EMERGENCE

All the dimensions are in millimeters.

Page 33: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

33

IDM

AX

®

Ø 4,6

0,8

Ø 4,900,50

R 2,50

55

Ø 5 IDMAX® Implants

Length: 6mm – Diameter 5mm IM+ 650

Length: 8mm – Diameter 5mm IM+ 850

Length: 10mm – Diameter 5mm IM+ 1050

Length: 12mm – Diameter 5mm IM+ 1250

Length: 15mm – Diameter 5mm IM+ 1550

Closing cap

Ø 4,9mm closing cap 541

Healing cap

Ø 4,9mm cylindrical healing cap; height: 5mm 513

Ø 4,9mm cylindrical healing cap; short head; height: 3,2mm 513C

Ø 4,9mm cylindrical healing cap; long head; height: 6,5mm 513L

Ø 5 MM IDMAX® EMERGENCE

Ø 5

MM

Page 34: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

34 www.idisystem.eu

FIXED PROSTHESIS

Burnout cylinders

Rotational incl. retaining screw P/N 1414 518S

Non rotational incl. retaining screw P/N 1414 H526S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50

Cylinder, gold, rotational to cast on + screw ASR50

Zirconia TiBase

Titan abutment basis + screw 7550

Titan abutments for a temporary toothNon rotational Ø 4,9mm incl. screw P/N 1414 APPH50

Rotational Ø 4,9mm incl. screw P/N 1414 APPR50

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Abutment, 5° angled + retaining screw P/N 0215

AM 5005G

Abutment, 15° angled + retaining screw P/N 0215

AM 5015G

Abutment, 23° angled + retaining screw P/N 0215

AM 5023G

Ø 5mm, 0-18° + retaining screw P/N 0215 HTU5G

Implant analog

For Ø 4,9mm IDMAX® implant 523

Prosthetic components

Ø 5 MM EMERGENCE

All the dimensions are in millimeters.

IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)

Page 35: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IDM

AX

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 35

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001

IDUnit attachment, Transgingival height: 2,5 mm U5002

IDUnit attachment, Transgingival height: 4 mm U5004

IDUnit attachment, Transgingival height: 6 mm U5006

17° angled IDUnit attachment (1 mm high) U5021

30° angled IDUnit attachment (1 mm high) U5031

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Ø 5

MM

Page 36: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

36 www.idisystem.eu

IDLoc

IDLoc attachments Transgingival height: 1 mm L5001

Transgingival height: 2,5 mm L5002

Transgingival height: 4 mm L5004

Transgingival height: 6 mm L5006

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222501

Transgingival height: 2,5 mm 222502

Transgingival height: 4 mm 222504

Transgingival height: 6 mm 222506

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 951

Magnetic 0940

REMOVABLE PROSTHESIS

Prosthetic components

Ø 5 MM EMERGENCE

All the dimensions are in millimeters.

Page 37: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDM

AX

®N

on c

ontra

ctua

l pic

ture

s

IDI IMPLANTS DIFFUSION INTERNATIONAL 3737

IDM

AX

®

0,8

0,50Ø 6,60

Ø 6

R 4

6,66,6

Ø 6,6 IDMAX® Implants

Length: 8mm – Diameter 6,6mm IM+ 860

Length: 10mm – Diameter 6,6mm IM+ 1060

Length: 12mm – Diameter 6,6mm IM+ 1260

Length: 15mm – Diameter 6,6mm IM+ 1560

Closing cap

Ø 6,6mm closing cap 641

Healing cap

Ø 6,6mm cylindrical healing cap; height: 2,5mm 613C

Ø 6,6mm cylindrical healing cap; height: 5mm 613

Ø 6,6 MM IDMAX® EMERGENCE

Ø 6

,6 M

M

Page 38: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

38 www.idisystem.eu

FIXED PROSTHESIS

Burnout cylinders

Rotational incl. retaining screw P/N 1414 618S

Non rotational incl. retaining screw P/N 1414 H626S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH60

Cylinder, gold, rotational to cast on + screw ASR60

Zirconia TiBaseTitan abutment basis + screw with Platform switch method 7550

Titan abutments for a temporary toothNon rotational Ø 6,6mm incl. screw P/N 1414 APPH60

Rotational Ø 6,6mm incl. screw P/N 1414 APPR60

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Abutment, 5° angled + retaining screw P/N 1414

AM 6005

Abutment, 15° angled + retaining screw P/N 1414

AM 6015

Abutment, 23° angled + retaining screw P/N 1414

AM 6023

Ø 5mm, 0-18° + retaining screw P/N 1414 HTU6

Implant analog

For Ø 6,6mm IDMAX® implant 623

Prosthetic components

Ø 6,6 MM EMERGENCE

IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)

Page 39: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IDM

AX

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 39

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001

IDUnit attachment, Transgingival height: 2,5 mm U5002

IDUnit attachment, Transgingival height: 4 mm U5004

IDUnit attachment, Transgingival height: 6 mm U5006

17° angled IDUnit attachment (1 mm high) U5021

30° angled IDUnit attachment (1 mm high) U5031

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Ø 6,

6 M

M

Page 40: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

40 www.idisystem.eu

IDLoc

IDLoc attachments Transgingival height: 1 mm L5001

Transgingival height: 2,5 mm L5002

Transgingival height: 4 mm L5004

Transgingival height: 6 mm L5006

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222501

Transgingival height: 2,5 mm 222502

Transgingival height: 4 mm 222504

Transgingival height: 6 mm 222506

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 951

Magnetic 0940

REMOVABLE PROSTHESIS

Prosthetic components

Ø 6,6 MM EMERGENCE

Page 41: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 41

SCREW-RETAINED UNITARY ELEMENT FROM TITAN ELEMENT

Retaining screw

Non rotational burnout element

Screw-retained titan element

FOC

US O

N

PRO

STHE

TICS

PROSTHETIC REHABILITATION WITH A TITAN ELEMENT

Focus on prosthetics TRANSGINGIVAL TITAN KITS

SCREW-RETAINED BRIDGE OR CONNECTOR BAR FROM TITAN ELEMENT

Retaining screw

Non rotational burnout element

Screw-retained titan element

Page 42: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

42

Our teams of advisors pay particularly attention to your remarks concerning the use of IDI’s products. They are transmitted to the R&D team in order to satisfy you and to meet your expectations.

To give us your remarks concerning IDI’s products, you can reach our sales department : By phone at : +33 (0)1 48 70 70 48 or by mail to : [email protected]

TRAINING AND EXPERIENCE FEEDBACK /

SALES MANAGEMENT

Frédérique IDI export Manager and Michael IDI France sales manager are managing advisors team close to meet the practitioners expectations.

www.idisystem.eu

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Page 43: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

“I tried several brands and different implants during my career. The IDOT implant is, to my opinion, the ideal one: cylindrical, micro-threaded and aesthetic with a simplified prosthetic system. ”

Dr Eugenio B. (Italy)

43

IDOT / Range

Page 44: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

44 www.idisystem.eu

Instructions for use: IDOT 41. Last drill in the sequence: diameter 3.5

mm.2. Use the hexagonal screwdriver P/N 1046

or 1146 or 0146 or 0046 to screw the implant.

3. The IDOT 4 can be set using the one-step, the one and a half step or the two-step technique.

4. With poorly mineralised bone the last drill is only inserted up to a third of its length.

5. Use the manual thread tap P/N Tar4 for highly mineralized bone.

6. Use the screwdriver P/N 403, 403M or 403ML to screw the cover screw and healing screw manually at 5N.cm while omitting the ratchet.

IDOT 51. Last drill in the sequence: diameter 4

mm.2. Use the hexagonal screwdriver P/N

1046 or 1146 or 0146 or 0046 to screw the implant.

3. The IDOT 5 can be set using the one-step, the one and a half step or the two-step technique.

4. With poorly mineralised bone the last drill is only inserted up to a third of its length.

5. Use the manual thread tap P/N Tar5 for highly mineralized bone.

6. Use the screwdriver P/N 403, 403M or 403ML to screw the cover screw and healing screw manually at 5N.cm while omitting the ratchet.

Gold-polished esthetic neck

Mini-threads

Cylindrical

S.M.A. TiO2 state of surface

Ti6Al4V ELITitanium alloy

Convex apex

Range IDOT /

Page 45: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 45

IDO

T

Ø 4 mm

Ø 5 mm

Ø 4 mm

Ø 5 mm

Ø 4 mm

Ø 5 mm

Ø 4 mm

Ø 5 mm

IDOT 0840

IDOT 0850

IDOT 1040

IDOT 1050

IDOT 1240

IDOT 1250

IDOT 1540

IDOT 1550

IDOT IMPLANT RANGEIMPLANT TYPE LENGTH P/N

All the dimensions are in millimeters.

Color code*

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:

08 mm length10 mm length12 mm length15 mm length

LEN

GTH

8LE

NG

TH 1

0LE

NG

TH 1

2LE

NG

TH 1

5

8

8

10

10

12

12

15

15

4,44,4 4,94,9

EMERGENCE

THE

IMPL

AN

TS

LINES

Page 46: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

46 www.idisystem.eu

Ø 4

3,85

0,9

Ø 4,400,50

4

R 1,9

0,8

Ø 4

4,50

0,9

Ø 4,900,50

4

0,8

R 2,3IDOT 4

IDOT 5

SURGICAL PROTOCOL

EXAMPLE OF AN IDOT IMPLANT PLACEMENT

Insert the closing cap into the implant and suture.

The implant is covered with a membrane after six weeks if the gum has attained physiological thickness.

Complete the drill sequence - omitting the profile drill stage - until the required length and diameter are attained.

Insert the implant so that the gold neck remains exposed supracrestally.

3

4

21

Page 47: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 47

IDO

T

Ø 4

3,85

0,9

Ø 4,400,50

4

R 1,9

0,8

4,44,4

Ø4,4 IDOT Implants

Length: 8mm – Diameter 4,4mm IDOT 840

Length: 10mm – Diameter 4,4mm IDOT 1040

Length: 12mm – Diameter 4,4mm IDOT 1240

Length: 15mm – Diameter 4,4mm IDOT 1540

Closing cap

Ø 4,4mm closing cap 441

Healing cap

Ø 4,4mm cylindrical healing cap; height: 5mm 413

Ø 4,4mm cylindrical healing cap; short head; height: 3,2mm 413C

Ø 4,4mm cylindrical healing cap; long head; height: 6,5mm 413L

Ø 4,4 MM IDOT EMERGENCE

Ø 4,

4 M

M

Page 48: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

48 www.idisystem.eu

FIXED PROSTHESIS

Burnout cylinders

Rotational incl. retaining screw P/N 1414 418S

Non rotational incl. retaining screw P/N 1414 H426S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6440R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6441R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6442R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH44

Cylinder, gold, rotational to cast on + screw ASR44

Zirconia abutments

Titan abutment basis + screw 7544

Titan abutments for a temporary toothNon rotational Ø 4,4mm incl. screw P/N 1414 APPH44

Rotational Ø 4,4mm incl. screw P/N 1414 APPR44

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Abutment, 5° angled + retaining screw P/N 0215

AM 4405G

Abutment, 15° angled + retaining screw P/N 0215

AM 4415G

Abutment, 23° angled + retaining screw P/N 0215

AM 4423G

Ø 4mm, 0-18° + retaining screw P/N 0215 HTU4G

Implant analog

For Ø 4,4mm IDOT implant 423

Prosthetic components

Ø 4,4 MM EMERGENCE

All the dimensions are in millimeters.

IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)

Page 49: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 49

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4401

IDUnit attachment, Transgingival height: 2,5 mm U4402

IDUnit attachment, Transgingival height: 4 mm U4404

IDUnit attachment, Transgingival height: 6 mm U4406

17° angled IDUnit attachment (1 mm high) U4421

30° angled IDUnit attachment (1 mm high) U4431

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Ø 4,

4 M

MID

OT

Page 50: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

50 www.idisystem.eu

IDLoc

IDLoc attachments Transgingival height: 1 mm L4401

Transgingival height: 2,5 mm L4402

Transgingival height: 4 mm L4404

Transgingival height: 6 mm L4406

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222441

Transgingival height: 2,5 mm 222442

Transgingival height: 4 mm 222444

Transgingival height: 6 mm 222446

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 944

Magnetic 0940

REMOVABLE PROSTHESIS

Prosthetic components

Ø 4,4 MM EMERGENCE

All the dimensions are in millimeters.

Page 51: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

51

Ø 4

4,50

0,9

Ø 4,900,50

4

0,8

R 2,3

55

Closing cap

Ø 4,9mm closing cap 541

Healing cap

Ø 4,9mm cylindrical healing cap; height: 5mm 513

Ø 4,9mm cylindrical healing cap; short head; height: 3,2mm 513C

Ø 4,9mm cylindrical healing cap; long head; height: 6,5mm 513L

Ø 5 MM IDOT EMERGENCE

Ø 5

MM

IDO

T

Ø5 IDOT Implants

Length: 8mm – Diameter 5mm IDOT 850

Length: 10mm – Diameter 5mm IDOT 1050

Length: 12mm – Diameter 5mm IDOT 1250

Length: 15mm – Diameter 5mm IDOT 1550

Page 52: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

52 www.idisystem.eu

FIXED PROSTHESIS

Burnout cylinders

Rotational incl. retaining screw P/N 1414 518S

Non rotational incl. retaining screw P/N 1414 H526S

Titan transgingival kitsNon rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500H

Rotational element, 0,5mm high + Titan basis & Burnout element & Screw 6500R

Non rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501H

Rotational element, 1,5mm high + Titan basis & Burnout element & Screw 6501R

Non rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502H

Rotational element, 2,5mm high + Titan basis & Burnout element & Screw 6502R

Retaining screws

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0215

For prosthesis: ≤ 25N.cm maximum (Screw head: Ø 2,5mm) 1414

Gold cylindersCylinder, gold, non rotational to cast on + screw ASH50

Cylinder, gold, rotational to cast on + screw ASR50

Zirconia abutments

Titan abutment basis + screw 7550

Titan abutments for a temporary toothNon rotational Ø 4,9mm incl. screw P/N 1414 APPH50

Rotational Ø 4,9mm incl. screw P/N 1414 APPR50

Impression cylinders

Rotational, straight (for solidarized elements) 7210

Rotational, conical (for solidarized elements) 7211

Non rotational, closed tray technique (for an unitary implant) 905

Non rotational, pick-up technique, (for an unitary implant) 906

Golden tapped Hexagonal abutments

Abutment, 5° angled + retaining screw P/N 0215

AM 5005G

Abutment, 15° angled + retaining screw P/N 0215

AM 5015G

Abutment, 23° angled + retaining screw P/N 0215

AM 5023G

Ø 5mm, 0-18° + retaining screw P/N 0215 HTU5G

Implant analog

For Ø 4,9mm IDOT implant 523

Prosthetic components

Ø 5 MM EMERGENCE

All the dimensions are in millimeters.

IMPORTANT NOTICE: ALL prosthetic elements have to be used with the screwdrivers P/N 0014 ; 0114; 1014 and 1114 only. (Please refer to page 109)

Page 53: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

HEXAGONAL CONNECTION

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 53

IDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5001

IDUnit attachment, Transgingival height: 2,5 mm U5002

IDUnit attachment, Transgingival height: 4 mm U5004

IDUnit attachment, Transgingival height: 6 mm U5006

17° angled IDUnit attachment (1 mm high) U5021

30° angled IDUnit attachment (1 mm high) U5031

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

REMOVABLE PROSTHESIS

Ø 5

MM

IDO

T

Page 54: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

54 www.idisystem.eu

IDLoc

IDLoc attachments Transgingival height: 1 mm L5001

Transgingival height: 2,5 mm L5002

Transgingival height: 4 mm L5004

Transgingival height: 6 mm L5006

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222501

Transgingival height: 2,5 mm 222502

Transgingival height: 4 mm 222504

Transgingival height: 6 mm 222506

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 951

Magnetic 0940

REMOVABLE PROSTHESIS

Prosthetic components

Ø 5 MM EMERGENCE

All the dimensions are in millimeters.

Page 55: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 55

1 - REMOVE THE HEALING CAPS FROM THE IMPLANTS THANKS TO THE SQUARE-TIPPED SCREWDRIVER (P/N 0014 OR P/N 0114). TAKE THE IMPRESSION WITH THE IMPRESSION COPYINGS ADAPTED TO THE IMPLANT.2 - THE LAB PREPARES THE MASTER MODEL WITH THE CORRESPONDING IMPLANT ANALOGS AND POSITIONS THE APPROPRIATE IDLOC ABUTMENTS.3 - THE LAB TECHNICIAN POSITIONS THE WHITE BLOCK OUT SPACERS ONTO THE IDLOC ABUTMENTS, AND, FIX THE BOX IN THE NYLON RING (MALE PART).4 - THEN THE LAB TECHNICIAN PREPARES THE PROSTHESIS ACCORDING TO THE STANDARD PROCEDURE.

PROTOCOL FOR THE IDLOC PLACEMENT: DIRECT METHOD

1 - AFTER REMOVING THE HEALING CAPS FROM THE IMPLANTS, INSERT THE IDLOC ABUTMENT INTO THE IMPLANT ACCORDING TO THE HEIGHT OF THE GINGIVAL TISSUES. THE ABUTMENT SHALL EMERGE BY 1MM SUB-GINGIVAL ; SCREW IT WITH THE SQUARE-END SCREWDRIVER P/N 0014 OR P/N 0114.

2 - PLACE THE BLOCK OUT WHITE SPACER (SOFT MATERIAL) ON EACH IDLOC ABUTMENT AND FIX THE BOX WITH THE NYLON RING (MALE PART).

3 - MARK THE TOP OF THE BOXES WITH ACRYLIC PEN AND POSITION THE PROSTHESIS ABOVE THEM TO LOCATE THE PARTS TO BE HOLLOWED OUT. THEN, FILL IN THE EMPTIED PARTS WITH AUTO-POLYMERIZING RESIN.

4 - POSITION THE PROSTHESIS IN THE MOUTH AND TIGHTEN IT.- WAIT TILL POLYMERIZING PROCESS IS COMPLETED.- REMOVE THE PROSTHESIS AND THE WHITE SPACERS.- REMOVE THE EXCESS RESIN AND PLACE THE PROSTHESIS BACK IN THE PATIENT MOUTH.

Focus on prostheticsTHE IDLOC

PROTOCOL FOR THE IDLOC PLACEMENT: INDIRECT METHOD

FOC

US O

N

PRO

STHE

TICS

Page 56: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu56

With significant advances since 1987 in implantology innovation, IDI is recognized by professionals for its leadership concerning the Research and Development. Its team is in permanent thought with professionals, practitioners, sales and technical teams to finalize new products. The morse taper connection, today considered for its technological advance, is resulting from the collaboration of these teams.

A CONSTANT ADVANCE OF PRODUCTS IN R&D /

RESEARCH AND DEVELOPMENT

The Research and Develoment Department is highly involved in developing new products and is constant improving the range. The R&D uses simulation and 3D imagery techniques. The service also benefits from high technologies equipment to develop products.

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Page 57: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

MORSE TAPER CONNECTION

“I selected this implant because of its specific shape and because of its exceptional selfdrilling performances. The IDALL® eases and secures my surgery. My surgeries become a real pleasure.”

Dr Raphaël B. (France)

57

IDALL® / Range

Page 58: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

58 www.idisystem.eu

Range IDALL® /PRESENTATIONThe IDALL® range benefits from the latest technological advance, to be associated with the IDI fundamentals such as the S.M.A. and TiO2 state of surface common to all the implant ranges.

This self-drilling implant stands 75 N.cm screwing stress without being affected.The IDALL® implants draws special attention to itself thanks to its aesthetic gold polished neck, and thanks to its Platform switch that minimizes the bone loss and makes the crest extension being possible.Its design is specially studied to optimize the primary stabilization in any bone density and favor the immediate loading.

Features of the IDALL® implant- Cylindro-tapered shape- Platform switch- Gold neck- Ti6Al4V ELI titanium alloy- S.M.A. and TiO2 coated- Morse taper- Cam connection- Anti-unscrewing groove- Penetrating and condensing threads- Double twist threads- Catch base

Plateform Switch

Penetrating and condensing threads

Double twistthreads

Anti-unscrewing groove

Gold neck

CATCH BASE

There is one drill for each implant length.Sub-crestal Para-crestalSupra-crestal

Depth markings for an implant of 15mm length.

Page 59: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 59

MORSE TAPER CONNECTION

THE

IMPL

AN

TS

LIN

ESID

ALL

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

Ø 4,2 mm

Ø 5,2 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 4,2 mm

Ø 5,2 mm

IDA 1042

IDA 1052

IDA 1242

IDA 1252

IDA 1542

IDA 1552

IDA 1842

IDA 1852

IDALL® IMPLANT RANGE

IMPLANT TYPE LENGTH P/N

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® drills for the implants with a hexagonal connection:

All the dimensions are in millimeters.

Color code*

LEN

GTH

10

LEN

GTH

12

LEN

GTH

15

LEN

GTH

18

10

10

12

12

15

15

18

18

Ø 4,20

0,8

IDALL® 4,2

0,8

Ø 5,20

IDALL®

5,2

10 mm length12 mm length15 mm length18 mm length

Page 60: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

60 www.idisystem.eu

EXAMPLE OF AN IDALL® IMPLANT SETTING of Ø 4,2mm and 12 mm length (P/N IDA1242)

Use the 4 bladed drill of Ø 3,8mm P/N X1238 (Final drill, soft bone).

Place the IDA1242 implant with the screwdriver P/N 0046 or 1046.

21

FOR THE MAXILLA

Use the 4 bladed drill of Ø 3,8mm P/N X1238.

Use the 4 bladed drill of Ø 4,2mm P/N X1242.

21

Place the IDA1242 implant with the screwdriver P/N 0046 or 1046.

3

FOR THE MANDIBLE

- The rotation speed for all drills is 1 500 rpm with ample cooling with physiological serum.- The four-bladed drills must be used without in and out movments.- The recommended rotation speed to set an implant is 15 rpm.- The insertion torque during the implant setting may be superior to 50 Ncm with a screwdriver P/N 0046 or 0146;- When the implant is placed on soft bone or very poor mineralized bone (Type IV), use the drill whose diameter is lower than the implant one.- Finish tightening the implant with the ratchet P/N 415 and the screwdriver P/N 0046 or 0146.- The placement of implant can be performed with help of the manual screwdriver P/N 0846.- To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.

SURGICAL PROTOCOL

Page 61: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 61

Ø 4,20

0,8

4,24,2

Ø4,2 IDALL® Implant

Length: 10mm – Diameter 4,2mm IDA 1042

Length: 12mm – Diameter 4,2mm IDA 1242

Length: 15mm – Diameter 4,2mm IDA 1542

Length: 18mm – Diameter 4,2mm IDA 1842

Closing cap

Ø 4,2mm closing cap 021201

Healing cap

Ø4,2 mm ( low part) - Ø6 mm (high part) – Heigth: 4 mm 021342

Ø4,2 mm (low part) - Ø6 mm (high part) – Heigth: 6 mm 021343

Ø 4,2 MM IDALL® EMERGENCE

Ø 4

,2 M

M

Healing cap for Platform switch methodTransgingival heigth

screw Ø 3,2mm (low part Ø 3,1mm)

screw Ø 4mm (low part Ø 3,6mm)

screw Ø 5mm (low part Ø 3,6mm)

screw Ø 6mm (low part Ø 3,6mm)

2mm021300 021350

4mm021304 021301 021354 021302

6mm0213 021306 021356 021303

8mm021348 021358 021308

Page 62: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

62 www.idisystem.eu

Prosthetic components

Ø 4,2 MM EMERGENCE

FIXED PROSTHESIS

Titan abutments for a temporary toothNon rotational Ø 4,2mm incl. screw 2064

Rotational Ø 4,2mm incl. screw 2084

Impression cylinders

Rotational, conical 0220C

Rotational 0221

Non rotational, pick-up technique (with screw) 2004

Non rotational, closed tray technique (with screw) 2004F

Screw-on morse tapered abutmentsAbutment, straigth, with shoulder Transgingival heigth: 1,5mm; incl. screw 420001

Abutment, straigth, with shoulder Transgingival heigth: 2,5mm; incl. screw 420002

Abutment, straigth, with shoulder Transgingival heigth: 3,5mm; incl. screw 420003

Abutment, 15° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 421501

Abutment, 15° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 421502

Abutment, 15° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 421503

Abutment, 23° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 422301

Abutment, 23° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 422302

Abutment, 23° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 422303

Implant analog

IDALL® analog 0224

Titan abutments for platform switch method (Ø3,6)

Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420011

Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420012

15° angled Transgingival heigth: 1,5mm; incl. screw 421511

15° angled Transgingival heigth: 3,0mm; incl. screw 421512

23° angled Transgingival heigth: 1,5mm; incl. screw 422311

23° angled Transgingival heigth: 3,0mm; incl. screw 422312

Page 63: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 63

Ø 4

,2 M

M

Burnout cylindersRotational, with shoulder incl. retaining screw P/N 0214 2184

Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6420H

Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6420R

Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6421H

Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6421R

Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6422H

Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6422R

Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)

0214

For prosthesis, short head ≤ 25N.cm maximum 0219

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0211

Gold cylindersCylinder, gold, non rotational to cast on + screw - Gold morse taper connection 642

Screw-on abutments Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420021

Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420022

15° angled Transgingival heigth: 1,5mm; incl. screw 421521

15° angled Transgingival heigth: 3,0mm; incl. screw 421522

23° angled Transgingival heigth: 1,5mm; incl. screw 422321

23° angled Transgingival heigth: 3,0mm; incl. screw 422322

Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636

Titan abutment basis + screw for lab 7542

Titan abutment basis + screw Platform switch (Ø3,6), for lab 7536

Page 64: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

64 www.idisystem.eu

All the dimensions are in millimeters.

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U4201

IDUnit attachment, Transgingival height: 2,5 mm U4202

IDUnit attachment, Transgingival height: 4 mm U4204

IDUnit attachment, Transgingival height: 6 mm U4206

17° angled IDUnit attachment (1 mm high) U4221

30° angled IDUnit attachment (1 mm high) U4231

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Prosthetic components

Ø 4,2 MM EMERGENCE

Page 65: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 65

Ø 4

,2 M

M

IDLoc

IDLoc attachments Transgingival height: 1 mm L4201

Transgingival height: 2,5 mm L4202

Transgingival height: 4 mm L4204

Transgingival height: 6 mm L4206

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222421

Transgingival height: 2,5 mm 222422

Transgingival height: 4 mm 222424

Transgingival height: 6 mm 222426

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 942

Magnetic 0940

Page 66: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

66 www.idisystem.eu

SURGICAL DRILL SET FOR THE IDALL® IMPLANTS

CONTENTS: 2 pilot drills12 cylindro-tapered drills with 4 bladed edges11 relating instruments

P/N 415

P/N 0114

P/N 406

P/N 1114

P/N 420

P/N 0014

P/N 412

Hand piece screwdriver for prosthetics, length: 30mm

Contra angle screwdriver for prosthetics, length: 30mm

Hand piece screwdriver for screwing the implant, length: 22mm

Ratchet Instrument extension

Implant paralleling help by 3

Depth tester

RANGE OF IDALL® DRILLS

Ø 3,8 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 3,8 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 3,8 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 3,8 mm

Ø 4,2 mm

Ø 5,2 mm

X1038

X1042

X1052

X1238

X1242

X1252

X1538

X1542

X1552

X1838

X1842

X1852

DRILLING LENGTH

DRILLING LENGTHP/N P/N

Color code* Color code*

18

18

18

10

10

10

12

12

12

15

15

15

P/N 1014

Hand piece screwdriver for prosthetics, length: 22mm

P/N 0146 P/N 1146 P/N 0046

Hand piece screwdriver for screwing the implant, length: 30mm

Contra angle screwdriver for screwing the implant, length: 30mm

Hand piece screwdriver for screwing the implant, length: 22mm

P/N 1046

Hand piece screwdriver for screwing the implant, length: 32mm

Page 67: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 67

SURGICAL DRILL SET FOR THE IDALL® IMPLANTS

0,8

Ø 5,20

5,25,2

Ø5,2 IDALL® Implants

Length: 10mm – Diameter 5,2mm IDA1052

Length: 12mm – Diameter 5,2mm IDA1252

Length: 15mm – Diameter 5,2mm IDA1552

Length: 18mm – Diameter 5,2mm IDA1852

Closing cap

Ø 5,2mm closing cap 021202

Healing cap

Ø5,2 mm ( low part) - Ø6 mm (high part) – Heigth: 4 mm 021352

Ø5,2 mm (low part) - Ø6 mm (high part) – Heigth: 6 mm 021353

Ø 5,2 MM IDALL® EMERGENCE

Ø 5

,2 M

M

Healing cap for Platform switch methodTransgingival heigth

screw Ø 3,2mm (low part Ø 3,1mm)

screw Ø 4mm (low part Ø 3,6mm)

screw Ø 5mm (low part Ø 3,6mm)

screw Ø 6mm (low part Ø 3,6mm)

2mm021300 021350

4mm021304 021301 021354 021302

6mm0213 021306 021356 021303

8mm021348 021358 021308

Page 68: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

68 www.idisystem.eu

Prosthetic components

Ø 5,2 MM EMERGENCE

FIXED PROSTHESIS

Titan abutments for a temporary toothNon rotational Ø 5,2mm incl. screw 2065

Rotational Ø 5,2mm incl. screw 2085

Impression cylinders

Rotational, conical 0220C

Rotational 0221

Non rotational, pick-up technique (with screw) 2004

Non rotational, closed tray technique (with screw) 2004F

Screw-on morse tapered abutmentsAbutment, straigth, with shoulder Transgingival heigth: 1,5mm; incl. screw 420001

Abutment, straigth, with shoulder Transgingival heigth: 2,5mm; incl. screw 420002

Abutment, straigth, with shoulder Transgingival heigth: 3,5mm; incl. screw 420003

Abutment, 15° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 421501

Abutment, 15° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 421502

Abutment, 15° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 421503

Abutment, 23° angled, with shoulder Transgingival heigth: 1,5mm; incl. screw 422301

Abutment, 23° angled, with shoulder Transgingival heigth: 2,5mm; incl. screw 422302

Abutment, 23° angled, with shoulder Transgingival heigth: 3,5mm; incl. screw 422303

Implant analog

IDALL® Analog 0225

Titan abutments for platform switch method (Ø4,2)

Straigth, 0° Transgingival heigth: 1,5mm; incl. screw 420021

Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 420022

15° angled Transgingival heigth: 1,5mm; incl. screw 421521

15° angled Transgingival heigth: 3,0mm; incl. screw 421522

23° angled Transgingival heigth: 1,5mm; incl. screw 422321

23° angled Transgingival heigth: 3,0mm; incl. screw 422322

Page 69: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 69

Screw-on abutmentsStraigth, 0° Transgingival heigth: 1,5mm; incl. screw 520021

Straigth, 0° Transgingival heigth: 3,0mm; incl. screw 520022

15° angled Transgingival heigth: 1,5mm; incl. screw 521521

15° angled Transgingival heigth: 3,0mm; incl. screw 521522

23° angled Transgingival heigth: 1,5mm; incl. screw 522321

23° angled Transgingival heigth: 3,0mm; incl. screw 522322

Ø 5

,2 M

M

Burnout cylindersRotational, with shoulder incl. retaining screw P/N 0214 2185

Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6520H

Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6520R

Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6521H

Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6521R

Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6522H

Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6522R

Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)

0214

For prosthesis, short head ≤ 25N.cm maximum 0219

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0211

Gold cylindersCylinder, gold, non rotational to cast on + screw - Gold morse taper connection 652

Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636

Titan abutment basis + screw for lab 7552

Titan abutment basis + screw Platform switch (Ø3,6), for lab 7542

Page 70: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

70 www.idisystem.eu

REMOVABLE PROSTHESISIDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U5201

IDUnit attachment, Transgingival height: 2,5 mm U5202

IDUnit attachment, Transgingival height: 4 mm U5204

IDUnit attachment, Transgingival height: 6 mm U5206

17° angled IDUnit attachment (1 mm high) U5221

30° angled IDUnit attachment (1 mm high) U5231

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Prosthetic components

Ø 5,2 MM EMERGENCE

All the dimensions are in millimeters.

Page 71: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDA

LL®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 71

Ø 5

,2 M

M

IDLoc

IDLoc attachments Transgingival height: 1 mm L5201

Transgingival height: 2,5 mm L5202

Transgingival height: 4 mm L5204

Transgingival height: 6 mm L5206

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222521

Transgingival height: 2,5 mm 222522

Transgingival height: 4 mm 222524

Transgingival height: 6 mm 222526

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 952

Magnetic 0940

Page 72: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

72

A particular attention is paid by the communication team to improve the quality of products’s imagery and to permit professionals to appreciate in an accuracy way the states of surface and the ergonomy of products of our several brands.

IDI equally participates to many conferences and appointments of the profession, in France and internationally.

QUALITY DEVOTED TO THE PRACTITIONER’S SERVICE /

COMMUNICATION

Our communication department develops many mediums to improve and perpetuate the relationship between the IDI departments and dental professionals.

www.idisystem.eu

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Page 73: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDCAM® / Range

MORSE TAPER CONNECTION

“On a surgical aspect, IDCAM® implants are easier and more pleasant to place comparing to other implants. Furthermore, with RBS® drills, we can harvest a great quantity of bone. On a prosthetic aspect, at this time I just have used the kit C for unit implants, and I think that’s an excellent one”

Dr Riad M. (Syria)

73

Page 74: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

74 www.idisystem.eu

WHY CHANGING FOR IDCAM® ?

WHY IDCAM® ?– For Technology and Innovation – For the IDCAM ® Concept– For the price

Its alloy - Two phases Ti6Al4V grade 5 Studies of Buser (2004), Zhao and Schwartz (2005), Carl E Misch.

Its state of surface - Sandblasted and acid-etched and TiO2, Roughness of 1,76μ – Sandblasted and acid-etched, passivated.

Studies of Becker and Coll, Albrektsson and Wennerberg, Wennerberg, Hanson and Norton 2005.

Its shape - Cylindro-tapered.– The cylindrical shape of implant neck reduces the stress

at the level of the crestal bone. – The tapered shape enables a better insertion between

adjacent teeth.Studies: comparative assessment of implant shape (influence of diameter, length and taper on alveolar bone stress).

Its Threads - Squared-shape and V-shape.Studies of Carl E Misch , Bone Miller.

Its Switching cone Studies: Hüzeler M, Fickl S, Zuhr O, wachtel HC in J Oral Maxilofac Surg 2008 Oct 66(10) 2195-6.

Its Morse taper and Cam RetentionStudies: prospective evaluation of 1 920 implants with morse taper connection. Clin Oral Implants Res 2009 Mar, 20(3), 254-61.

IDCAM ® implant has all features approved by the science and more over!

Studies performed by Pr P.E. Crubillé.

There’s more than 1000 brands of dental implants all over the world.

COMPENDIUM OF SCIENCES APPROVED TECHNOLOGIES

Maximal shearing stress

In this tridimensional finite elements study, the shearing force is the same for V-shaped and reverse V-shaped threads. However, the study shows that the squared-shaped thread reduces shearing forces for the same load.

2,00E+07

1,50E+07

1,00E+07

5,00E+06

0,00E+00 Reverse1,43E+07 1,43E+071,03E+07Maximal

shearing

Maximal shearing stress

Squarred V-shapped

Page 75: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDC

AM

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 75

THE

IMPL

AN

TS

LINES

RADIOGRAPHIC EXAMINATION Implant placement in canvas shapeTechnique of implant placement without any material.Implant pushing the Schneiderian membrane. The CSO® apex allows the realization of low-risk surgery.

Implant : IDCAM®

Reduces the risk of perforating the Schneiderian membrane.

Others Implants The implant perforated the membrane.

Its CSO® apexConcaveThe concave area allows to sustain grafted biomaterials during sinus lift. SafetyThe atraumatic round-shaped end limits the risks of damaging neighbouring tissues. OsseointegrationThe peripheral wedge groove increases the apical bone retention surface.

Internal part of IDCAM®

Cam retention For a better connection accuracy.2,5° Morse taperInternal Universal ISO threading

Groove of IDCAM®

Helicoidal groove for an anti-unscrewing effect of implant. The internal part is the same, whatever the diameter of implant.

Bone density for IDCAM® S

Diameter of Apex : Ø 2,1 mmPhotos : Pr Bravetti.

Type I

Type III

Type II

Type IV

Bone quality classification of Lekholm & Zarb.

Bone quality classification of Lekholm & Zarb.

Bone density for IDCAM® M

Documents given by Pr P. Bravetti, Dean of the Odontologic Faculty of Nancy.

Page 76: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

76

Range IDCAM® S /STANDARD

www.idisystem.eu

PRESENTATIONThe IDCAM®S type IM implant line benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987.This self-condensing implant stands 75 N.cm screwing stress without being affected. The IDCAM®S implant draws special attention to itself due to its Switching Cone neck and to its cylindro-tapered body identical to a dental root.The angulation, the state and the depth of the threads arespecially studied to optimize the primary stabilization in any bone density and favor the immediate loading.

Implant IDCAM®S features- Cylindro-tapered-shaped- 2,5° morse taper- Titanium alloy Ti6Al4V ELI- SMA + Ti02 state of surface- Cam retention- Switching Cone- Anti-unscrewing grooves- Progressive and condensing threads- CSO® apex

Switching Cone

Self-drilling low threads

Condensing high threads

Anti-unscrewing groove

Advantages of the CSO® APEX

CSO®

APEX

The IDCAM® implant draws special attention to themself because of its CSO® apex*.

Its apex has a concave area that acts as a bone reservoir for bone grafting. The atraumatic « Securit » round-shaped end limits the risks of damaging the sinus membrane and the dental nerve. Its peripheral and wedging groove increases the apical bone retention surface.*CSO ® : Concave Securit Osseo-wedging.Maxillary

Mandible

Page 77: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 77

MORSE TAPER CONNECTION

THE

IMPL

AN

TS

LINES

IDC

AM

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

non

cont

ract

ual p

ictu

res

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® implants :

08 mm length10 mm length12 mm length15 mm length

Standard Ø 4,2 mm

Standard Ø 5,2 mm

Standard Ø 3,5 mm

Standard Ø 4,2 mm

Standard Ø 5,2 mm

Standard Ø 3,5 mm

Standard Ø 4,2 mm

Standard Ø 5,2 mm

Standard Ø 3,5 mm

Standard Ø 4,2 mm

Standard Ø 5,2 mm

IDCS 0842

IDCS 0852

IDCS 1035

IDCS 1042

IDCS 1052

IDCS 1235

IDCS 1242

IDCS 1252

IDCS 1535

IDCS 1542

IDCS 1552

IDCAM® S IMPLANT RANGEIMPLANT TYPE LENGTH P/N

Important considerations

The 3,5mm diameter implants must be used only for lower and upper lateral incisors.The 8mm IDCAM® implants do not have any CSO® Apex.

The IDCAM® implants are supplied with a closing and a healing cap.To improve aesthetic quality, it is recommended to position the implant under 1mm of the bone crest.

It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.The length choice and diameter of implant must be based on the bone density determined by the CT- scan.

!

All the dimensions are in millimeters.

Color code*

NB: The 8mm length of IDCAM® implants (P/N IDCS 0842 and IDCS 0852) do not have any CSO® APEX.

LEN

GTH

8LE

NG

TH 1

0LE

NG

TH 1

2LE

NG

TH 1

5

8

8

10

10

10

12

12

12

15

15

15

Ø 3,7

3,60

0,8

Ø 4,20

Ø 3,60

0,8

Ø 5,20

Ø 3,60

0,8

IDCAM® S 3,5

IDCAM® S 4,2

IDCAM® S 5,2

Page 78: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

78 www.idisystem.eu

Range IDCAM® M /MINI-THREADS

PRESENTATIONThe IDCAM®M type IM implant line benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987.This self-condensing implant stands 75 N.cm screwing stress, without being affected.The IDCAM®M implant differentiates from the IDCAM®S because of its mini threads neck, which favor immediate loading.

Implant IDCAM®M features- Cylindro-tapered-shaped

- 2,5° morse taper

- Titanium alloy Ti6Al4V ELI

- SMA + Ti02 state of surface

- Cam retention

- Switching Cone

- Anti-unscrewing grooves

- Mini threads

- Progressive and condensing threads

- CSO® apex

Instructions for use1. Use the screwdriver P/N 0146, 1046,

0046, 0846 to screw the implant.2. Use the screwdriver P/N 0014, 1014,

1114, 0114 to screw the cover screw manually at 5N.cm while omitting the hinged ratchet.

Switching Cone

Self-drilling low threads

Condensing mini threads

Condensing high threads

Anti-unscrewing groove

CSO®

APEX

Morse taper and identical connection for all IDCAM® range.

2,5° morse taper

Cam connection

Internal universal thread ISO

Page 79: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 79

MORSE TAPER CONNECTION

THE

IMPL

AN

TS

LINES

IDC

AM

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

non

cont

ract

ual p

ictu

res

*On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® implants :

08 mm length10 mm length12 mm length15 mm length

Mini-threads Ø 4,2 mm

Mini-threads Ø 5,2 mm

Mini-threads Ø 4,2 mm

Mini-threads Ø 5,2 mm

Mini-threads Ø 4,2 mm

Mini-threads Ø 5,2 mm

Mini-threads Ø 4,2 mm

Mini-threads Ø 5,2 mm

IDCM 0842

IDCM 0852

IDCM 1042

IDCM 1052

IDCM 1242

IDCM 1252

IDCM 1542

IDCM 1552

IDCAM® M IMPLANT RANGEIMPLANT TYPE LENGTH P/N

All the dimensions are in millimeters.

Color code*

NB: The 8mm length of IDCAM® implants (P/N IDCS 0842 and IDCS 0852) do not have any CSO® APEX.

LEN

GTH

8LE

NG

TH 1

0LE

NG

TH 1

2LE

NG

TH 1

5

8

8

10

10

12

12

15

15

Important considerations

The 3,5mm diameter implants must be used only for lower and upper lateral incisors.The 8mm IDCAM® implants do not have any CSO® Apex.

The IDCAM® implants are supplied with a closing and a healing cap.To improve aesthetic quality, it is recommended to position the implant under 1mm of the bone crest.

It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.The length choice and diameter of implant must be based on the bone density determined by the CT- scan.

!

Ø 4,20

3,60

0,8

Ø 5,20

0,8

Ø 3,60

IDCAM® M 4,2

IDCAM® M 5,2

Page 80: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

80 www.idisystem.eu

Important considerations about IDCAM®:The Ø 3,5mm IDCAM® implants are reserved for the upper lateral incisors and lower incisors only.

IDCAM® implants of 8mm length do not have Apex CSO.

The IDCAM® implants are supplied with a sterile closing cap and a healing cap.To optimize the aesthetic result, it is recommended to set the 1mm implant in a sub-crestal position.

It is recommended to set as many implants as lacking natural roots in the patient mouth in order to secure the lasting of the prosthesis.

The length choice and implant diameter must be based on the bone density determined by the CT-scan.

!

Ø 4,2 mm

Ø 5,2 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

IDCM & S 0842

IDCM & S 0852

LENGTHDRILL TO USE

IDCAM® P/N

Color code*

IDCS 1035

IDCM & S 1042

IDCM & S 1052

IDCS 1235

IDCM & S 1242

IDCM & S 1252

IDCS 1535

IDCM & S 1542

IDCM & S 1552

All the dimensions are in millimeters.

8

8

10

10

10

12

12

12

15

15

15

IDCAM®

SURGICAL PROTOCOLEXAMPLE OF AN IDCAM® IMPLANT (example with the implant placement for an IDCAM® implant P/N: IDCM1242)

321

5 64

Suture.

Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.

Screw the implant P/N IDCM1242 :• with the help of a contra-angled handpiece and a screwdriver P/N.:1046 or 1146;• or with the screwdriver P/N: 0846.Finish screwing the paracrestal implant with the screwdriver P/N.:1146 or 1046 and the ratchet P/N.:414.

Use the Pilot drill P/N.:1220 of 2mm diameter & 12mm length. Drill at 350 rpm with ample cooling.

Screw the cover screw at 5N.cm with the screwdriver P/N.:0014 or P/N.: 0114.

Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 350 rpm. If drilling procedure with bone harvesting: 100 rpm.

(This step is to be performed for an implant placement at the mandibule only.)

Page 81: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 81

MORSE TAPER CONNECTION

THE

IMPL

AN

TS

LINES

IDC

AM

®

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

non

cont

ract

ual p

ictu

res

IDCAM® RANGES

Closing cap

IDCAM® closing cap 0212

IDCAM® mini-threaded implants

Length 8 - Mini-threaded Ø4,2 mm IDCM 0842

Length 8 - Mini-threaded Ø5,2 mm IDCM 0852

Length 10 - Mini-threaded Ø4,2 mm IDCM 1042

Length 10 - Mini-threaded Ø5,2 mm IDCM 1052

Length 12 - Mini-threaded Ø4,2 mm IDCM 1242

Length 12 - Mini-threaded Ø5,2 mm IDCM 1252

Length 15 - Mini-threaded Ø4,2 mm IDCM 1542

Length 15 - Mini-threaded Ø5,2 mm IDCM 1552

IDCAM® standard implants

Length 8 - Standard Ø4,2 mm IDCS 0842

Length 8 - Standard Ø5,2 mm IDCS 0852

Length 10 - Standard Ø3,5 mm IDCS 1035

Length 10 - Standard Ø4,2 mm IDCS 1042

Length 10 - Standard Ø5,2 mm IDCS 1052

Length 12 - Standard Ø3,5 mm IDCS 1235

Length 12 - Standard Ø4,2 mm IDCS 1242

Length 12 - Standard Ø5,2 mm IDCS 1252

Length 15 - Standard Ø3,5 mm IDCS 1535

Length 15 - Standard Ø4,2 mm IDCS 1542

Length 15 - Standard Ø5,2 mm IDCS 1552

Healing cap for FMCTransgingival heigth

screw Ø 3,2mm (low part Ø 3,1mm)

screw Ø 4mm (low part Ø 3,6mm)

screw Ø 5mm (low part Ø 3,6mm)

screw Ø 6mm (low part Ø 3,6mm)

2mm021300 021350

4mm021304 021301 021354 021302

6mm0213 021306 021356 021303

8mm021348 021358 021308

Page 82: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

82 www.idisystem.eu

PROSTHETIC KITS

Implant analog

P/N 0223

Burnout cylinder, rotational

P/N 021801

Burnout connector bar

P/N 0931

Nylon clip

P/N 0025

KIT A – The screw-on burnout elements for any type of prosthetic reconstructions

L N P Q SRetaining

screw

P/N 0214

Contents of kit A

Excluded from Kit A, C or D

Impression cylinder, rotational

P/N 0221

U

Impression cylinder incl. screw, non rotational Pick-up technique

P/N 2004

TNon-rotational, closed tray technique

P/N 2004F

F

Conical rotational

P/N 0220C

W

CONNECTOR BAR WITH SPHERICAL ATTACHMENTS– The impression is taken with the impression cylinders (P/N 0221 or 2004)

– The implant analogs (P/N 0223) are screwed onto the impression cylinders and are plastered over.

P

L

N

Page 83: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

PRO

STHE

TIC

CO

MPO

NEN

TSID

CA

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 83

CONNECTOR BAR WITH CLIPS– The impression

is taken with the impression cylinders (P/N 0221 or 2004)

– The implant analogs are screwed onto the impression cylinders; the model is plastered over (P/N 0223)

SCREW-ON SOLIDARIZED ABUTMENTS + SOLIDARIZED FRAMEWORK– The impression is taken with the impression cylinders (P/N 0221 or

0221C)

– The model is plastered over

– Conception of the framework with P/N 021801 and 0214

– Realization of the ceramic work on a telescopic framework

Setting

X

U

P

S

L

N

P

L

N

Page 84: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

PROSTHETIC KITS

All the dimensions are in millimeters.

84 www.idisystem.eu

KIT C – Fixed screw-on CoNe® for an unitary implant (FMC)

K P LScrew-on machined

abutment 6 P/N*

Retaining screwP/N 0211

Implant analogP/N 0223

Contents of kit C

*Different types of abutments for ø 3,5 implant:

*Different types of abutments for ø 4,2 et 5,2 implants:

- Straight abutment : P/N 3500- 15° angled abutment : P/N 3515- 23° angled abutment : P/N 3523

- Straight abutment : P/N 4200- 15° angled abutment : P/N 4215- 23° angled abutment : P/N 4223

NB: Identical morse taper for every external ø of implants (ø 3,5, ø 4,2, ø5,2).

Abutment remover for tapered implants (IDCAM® and IDALL® product lines)

P/N 0148

X

K

Page 85: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

PRO

STHE

TIC

CO

MPO

NEN

TSID

CA

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 85

M P LFlat supported abutment

6 P/N*

Retaining screwP/N 0211

Implant analogP/N 0223

Content of kit D

KIT D – Fixed screw-on PLAN® abutments for unitary or multiple implants (FMP)

*Different types of abutments for 1,5 mm transgingival height for all types of implants:

*Different types of abutments for 3,0 mm transgingival height for all types of implants:

- Straight abutment: P/N 420011- 15° angled abutment: P/N 421511- 23° angled abutment: P/N 422311

- Straight abutment: P/N 420012- 15° angled abutment: P/N 421512- 23° angled abutment: P/N 422312

X

Comparison between the CôNe abutment and the PLAN® abutment

PLAN®

Screw-on abutment to 25 N.cm

Position the abutment

Screw the abutment to

25 N.cm

CôNe®

NB: Identical morse taper for every external ø of implants (ø 3,5, ø 4,2, ø5,2).

M

Page 86: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

86 www.idisystem.eu

PROSTHETIC COMPONENTSFIXED PROSTHESIS

Titan abutments for a temporary toothNon rotational incl. screw 0206

Rotational incl. screw 0208

Impression cylinders

Rotational, conical 0220C

Rotational 0221

Non rotational, pick-up technique (with screw) 2004

Non rotational, closed tray technique (with screw) 2004F

Morse tapered abutments (FMC) with shoulderStraigth, incl. screw Transgingival height: 1,5mm 420001

Straigth, incl. screw Transgingival height: 2,5mm 420002

Straigth, incl. screw Transgingival height: 3,5mm 420003

15° angled, incl. screw Transgingival height: 1,5mm 421501

15° angled, incl. screw Transgingival height: 2,5mm 421502

15° angled, incl. screw Transgingival height: 3,5mm 421503

23° angled, incl. screw Transgingival height: 1,5mm 422301

23° angled, incl. screw Transgingival height: 2,5mm 422302

23° angled, incl. screw Transgingival height: 3,5mm 422303

Implant analog

IDCAM® Analog 0223

Morse tapered abutments (FMC) without shoulderMorse taper abutment, straigth, 0° Width: 3,5mm; incl. screw 3500

Morse taper abutment, straigth, 15° Width: 3,5mm; incl. screw 3515

Morse taper abutment, straigth, 23° Width: 3,5mm; incl. screw 3523

Morse taper abutment, straigth, 0° Width: 4,2mm; incl. screw 4200

Morse taper abutment, straigth, 15° Width: 4,2mm; incl. screw 4215

Morse taper abutment, straigth, 23° Width: 4,2mm; incl. screw 4223

KIT C - Morse tapered CôNe abutments (FMC)

3500 + 0211 + 0223 Kit C300

3515 + 0211 + 0223 Kit C315

3523 + 0211 + 0223 Kit C323

4200 + 0211 + 0223 Kit C400

4215 + 0211 + 0223 Kit C415

4223 + 0211 + 0223 Kit C423

Page 87: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

PRO

STHE

TIC

CO

MPO

NEN

TSID

CA

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 87

Burnout cylinders

Rotational, with shoulder 021801

Non-rotational, with shoulder in nylon, for temporary tooth 022602

0223 + 0214 + 021801 + 0931 + 0025 Screw-on burnout elements for any type of prosthetic reconstructions

Kit A

Titan transgingival kitsNon rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6360H

Rotational element, 0,4mm high + Titan basis & Burnout element & Screw 6360R

Non rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6361H

Rotational element, 1,4mm high + Titan basis & Burnout element & Screw 6361R

Non rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6362H

Rotational element, 2,4mm high + Titan basis & Burnout element & Screw 6362R

Retaining screwsRetaining screw for IDCAM® and IDALL® ≤ 25N.cm maximum (Screw head: Ø 2,5 mm)

0214

For prosthesis, short head ≤ 25N.cm maximum 0219

Golden Retaining screw for tapped screw-retained elements (Screw head: Ø 2,2mm)

0211

Gold cylindersCylinder, gold, non rotational to cast on + screw - Morse taper connection 636

Screw-on abutments (FMP) with shoulderStraigth, 0°, incl. screw Transgingival height: 1,5mm 420011

Straigth, 0°, incl. screw Transgingival height: 3,0mm 420012

15° angled, incl. screw Transgingival height: 1,5mm 421511

15° angled, incl. screw Transgingival height: 3,0mm 421512

23° angled, incl. screw Transgingival height: 1,5mm 422311

23° angled, incl. screw Transgingival height: 3,0mm 422312

Kit D (FMP) with shoulder

420011 + 0211 + 0223 Kit D400

421511 + 0211 + 0223 Kit D415

422311 + 0211 + 0223 Kit D423

Zirconia TiBaseTitan abutment basis + screw conical, for lab 7636

Titan abutment basis + screw Platform switch (Ø3,6), for lab 7536

Page 88: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

All the dimensions are in millimeters.

88 www.idisystem.eu

PROSTHETIC COMPONENTSREMOVABLE PROSTHESIS

IDUnit

IDUnit elements IDUnit attachment, Transgingival height: 1 mm U3601

IDUnit attachment, Transgingival height: 2,5 mm U3602

IDUnit attachment, Transgingival height: 4 mm U3604

IDUnit attachment, Transgingival height: 6 mm U3606

17° angled IDUnit attachment (1 mm high) U3621

30° angled IDUnit attachment (1 mm high) U3631

IDUnit analog IDUnit analog 333

IDUnit burnout element IDUnit burnout element + screw P/N 0216 336S

Titan cylinder Temporary cylinder for IDUnit attachment + screw P/N 0216 334

Impression copying Impression copying, monobloc, to be screwed 321

IDUnit impression copying, Pick-up technique 322

Impression copying, plastic 335

Healing cap IDUnit healing cap 330

Retaining screw For prosthetic elements P/N 334, 336; Torque ≤ 15N.cm 0216

Page 89: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

PRO

STHE

TIC

CO

MPO

NEN

TSID

CA

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

MORSE TAPER CONNECTION

IDI IMPLANTS DIFFUSION INTERNATIONAL 89

IDLoc

IDLoc attachments Transgingival height: 1 mm L3601

Transgingival height: 2,5 mm L3602

Transgingival height: 4 mm L3604

Transgingival height: 6 mm L3606

Impression copying Impression copying, plastic 432

Analog IDLoc analog 433

Box Female part LOCFEM

Spherical attachments

Transgingival height: 1 mm 222361

Transgingival height: 2,5 mm 222362

Transgingival height: 4 mm 222364

Transgingival height: 6 mm 222366

Burnout spherical attachments

Burnout spherical attachment 9222

Paralleling guide for burnout spherical attachment 9223

Boxes for spherical attachmentsO’ring, Heigth: 3,5mm External Ø : 5mm 0122

O’ring retaining ring for O’ring attachment 0120

Nylon box for spherical attachment 0924

Connector barBurnout connector bar (by 3) 0931

Nylon clip 0025

Magnetic screws

Screw, REDEIM type 0024

Magnetic 0940

Page 90: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

90 www.idisystem.eu

Focus on prosthetics THE IDUNIT

PROTOCOL FOR IDUNIT PLACEMENT

1 - REMOVE THE HEALING CAPS FROM THE IMPLANTS WITH THE ADAPTED SCREWDRIVER. INSERT THE APPROPRIATE IDUNIT ABUTMENT ONTO THE IMPLANT AND TIGHTEN IT TO 25 N.CM WITH THE SQUARE-TIPPED SCREWDRIVER (P/N 0014 OR P/N 0114). IT IS RECOMMENDED TO CARRY OUT A X-RAY CHECK ONCE THE ABUTMENT IS SCREWED.

2 - TAKE AN IMPRESSION WITH THE IMPRESSION COPYINGS:

CLOSED TRAY P/N 321

OPEN TRAY P/N 322

3 - POSITION THE PROSTHESIS IN THE PATIENT MOUTH AND SCREW IT WITH THE RETAINING SCREWS P/N 0216 AND TIGHTEN THEM TO 25N.CM WITH THE SCREWDRIVER P/N 0014 OR 0114.THE RETAINING SCREWS P/N 0216 AND TIGHTEN THEM TO 25N.CM WITH THE

CLOSED TRAY

P/N 321

OPEN TRAY

P/N 322

SCREWDRIVER P/N 0014 OR 0114.

Page 91: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 91

PRO

STHE

TIC

APP

ROA

CH

STABILIZATION BAR WITH CLIPS FOR OVERDENTURE

EXAMPLE OF PROSTHETIC REHABILITATIONS

SCREW-ON CERAMIC FROM BURNOUT CYLINDER

SCREW-ON BRIDGE FROM BURNOUT CYLINDERS

GENERAL PROSTHETIC APPROACH

Page 92: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

92 www.idisystem.eu

GENERAL PROSTHETIC APPROACH

BRIDGE ON MACHINED ABUTMENTS

STABILIZED OVERDENTURE WITH SCREWED TITAN SPHERICAL ATTACHMENTS AND O’RING BOXES

STABILIZED OVERDENTURE WITH IDLOC ATTACHMENTS

Page 93: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

93

The RBS® sets Surgical set

for IDCAM/BIO

tapered implants

RBS® C drill

Surgical sets for cylindrical implants

RBS® drill

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Page 94: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

94 www.idisystem.eu

CONTENTS :16 drills

7 relating instruments

SURGICAL DRILL SET FOR THE IDCAM®/IDBIO®

P/N 415

P/N 0114

P/N 406

P/N 1114

P/N 409

P/N 0146

P/N 408

Hand piece screwdriver for prosthetics, length: 30mm

Contra angle screwdriver for prosthetics, length: 30mm

Hand piece screwdriver for screwing the implant, length: 30mm

Ratchet Instrument extension

Implant paralleling help Ø1,5mm

Depth tester

INCLUDES: P/N 415Ratchet

Short hex-tipped screwdriver P/N 0046

Screwdriver for relating instruments (short model) P/N 0014

HOLDERS IN DIFFERENT SIZESThe holders contain 4 RBS®C conical drills for cylindro-tapered implants.There are available in 8mm length; 10 mm length; 12 mm length; 15 mm length.

Page 95: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IDI IMPLANTS DIFFUSION INTERNATIONAL 95

The bone-recovering RBS® tapered drills were developed and tested in several hospitals. They ease the implant setting of the IDBIO® and IDCAM ranges.

*On each implant’s packaging there is a small colored sticker to match with the implant height. The code for each color is related to the one found on the RBS® conical drills for the IDCAM® and IDBIO® implants.

Length: 8mm Length: 10mm Length: 12mm Length: 15mm

Ø 2,0 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 2,0 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 2,0 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

Ø 2,0 mm

Ø 3,5 mm

Ø 4,2 mm

Ø 5,2 mm

820

083522

084227

085230

1020

103522

104223

105225

1220

123522

124223

125225

1520

153522

154223

155225

RBS®C DRILLS RANGE

DRILLING LENGTH

DRILLING LENGTHP/N P/N

Color code* Color code*

Drill headThe lower section incorporates a long cutting thread and tapers to a point at the drill head.

Color codeA colored ring on the depth stop indicates the maximum drill depth.

MarkingsMarkings on the shank indicate the diameter of the drill.

Depth stopThe depth stop limits how deep

the drill can be inserted, determining the maximum drilling depth.

Bone-harvesting channelA channel between the cutting thread and depth stop is used to collect bone

material for harvesting autogenous material for grafting.

8

8

8

8

10

10

10

10

12

12

12

12

15

15

15

15

Non

con

tract

ual p

ictu

res a

nd p

acki

ng

THE RBS®C TAPERED DRILLS TH

E RB

SURG

ICA

L SET

S

Page 96: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

96 www.idisystem.eu

The RBS® 2 set provides for implantologists and perio- implantologists who want to harvest bone during surgery for an autogenous graft.

This set containing 20 drills can be used for placing numerous implant types with an internal or external hexagon. Pilot drills with a diameter of 1,5mm are included for facilitating surgery.

NB : drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.

RBS® 2

815

1015

1215

1515

R 825

R 1025

R 1225

R 1525

820

1020

1220

1520

R 830

R 1030

R 1230

R 1530

R 835

R 1035

R 1235

R 1535

COLOR CODE NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N NOTCHES P/N

1

1

1

1

3

3

3

3

2

2

2

2

4

4

4

4

5

5

5

5

RBS®

SURGICAL SETS

The RBS® 1 set provides safety for operators new to perio- implantology.The 12 drills in the set with a bone-harvesting channel are used to harvest autogenous graft material. They are used when placing cylindrical implants: 10mm, 12mm and 15mm of length with internal or external retention.

NB : Drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.

RBS® 1

1020

1220

1520

R 1030

R 1230

R 1530

R 1025

R 1225

R 1525

R 1035

R 1235

R 1535

COLOR CODE NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N

2

2

2

4

4

4

3

3

3

5

5

5

Page 97: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 97

Set contents

P/N 414 P/N 409 P/N 0046 P/N 1146

P/N 401

P/N 406

Profile drill

Ratchet + central part

Paralleling help of Ø mm implant

Contra-angle screwdriver hand piece for screwing the implant

Instrument extension

Hand piece screwdriver for screwing of the implant

P/N 403 ML P/N 0014 P/N 403

Square-tipped screwdriver, long, width 2 mm for closing and healing caps*

Square-tipped screwdriver, short, width 1.2 mm, for impression copings*

Square-tipped screwdriver, width 2mm for closing screw and healing cap

The RBS®3 set has the same feature as the RBS®2 set.This set contains 24 drills and additional instruments which are required to place implants up to 5 mm diameter.This set can be used for placing numerous implant types with an internal or external hexagon.

NB : drills with a diameter of 1.5 and 2 mm do not have a bone-harvesting channel.

RBS® 3

815

1015

1215

1515

R 825

R 1025

R 1225

R 1525

820

1020

1220

1520

R 830

R 1030

R 1230

R 1530

R 835

R 1035

R 1235

R 1535

R 840

R 1040

R 1240

R 1540

NOTCHES P/N NOTCHES P/NNOTCHES P/N NOTCHES P/N NOTCHES P/N NOTCHES P/N

1

1

1

1

3

3

3

3

2

2

2

2

4

4

4

4

5

5

5

5

6

6

6

6

* The RBS®1 set does not contain the elements ref 403ML and 0014.

THE

RBS®

SU

RGIC

AL S

ETS

COLOR CODE

Page 98: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu98

CYLINDRICAL RBS® DRILLSRBS® drills for harvesting bone were developed and tested in cooperation with dental hospitals. They are precisely tailored to user requirements and meet the highest standards of implantology and periodontal implantology.

Manufactured in accordance with the medical products directive, RBS® drills are made of hardened stainless steel. Their excellent cutting capacity ensures tissue heating is kept to an absolute minimum.NB: Drills with a diameter of 1,5 and 2 mm do not have a bone-harvesting channel.

Drilling procedure without bone harvesting

Drilling procedure with bone harvesting

Use the drills in an increasing sequence (in 0,5 mm stages) at a rotary speed of 250 rpm with ample cooling to avoid heating the bone.

- Use the drills in an increasing sequence (in 0.5 stages) at a rotary speed of 150 rpm without cooling.- When the bone-harvesting channel is full, place the drill in a

cup with physiological solution until the bone material loosens and settles on the bottom of the cup. Soak up the physiological solution and collect the bone material for the bone graft.

Depth stopLimits how deep the drill can be inserted, determining the maximum drilling depth.

Bone-harvesting channelA channel between the cutting thread and depth stop is used to collect bone material for harvesting autogenous material for grafting.

MarkingsMarkings on the

shank indicate the diameter of the drill:

Example for the IDI implants.

1 notch = Ø 1,5 mm2 notches = Ø 2,0 mm3 notches = Ø 2,5 mm4 notches = Ø 3,0 mm5 notches = Ø 3,5 mm6 notches = Ø 4,0 mm7 notches = Ø 4,5 mm8 notches = Ø 5,4 mm

Color codeA coloured ring on the depth stop indicates the maximum

drill depth (+/- 0,5 mm).

Example for the IDI implants:

Drill headThe lower section

incorporates a long cutting thread and tapers

to a point at the drill head.

Black = 6 mmYellow = 8mmRed = 10 mm

Green = 12mmBlue = 15mm

Page 99: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

99

The OsteosinusThe Osteosinus 1 set

Osteosinus

Rectisinus

Angulosinus

Forsinus

Trepanosinus

Diskosinus

Technique by using the Trepanosinus

Technique by using the Forsinus

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Page 100: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

“The Osteosinus system of IDI firm - Implants Diffusion International - is an easy and reliable technique when we want to place an implant in a sinusal area. It permits to each dentist to perform a sinus floor elevation by crestal approach. Drills manufactured for the bone preparation are accute and lasting. The RBS® system for the bone harvesting is terrific”

Dr Rainer B. (Germany)

Consistent use of a depth stop over many years when harvesting bone surgically and the experience this provided enabled development of this technique. The technique has proved itself in a wide range of applications for more than fifteen years thanks to the rbs depth stop drills from Implants Diffusion International.

Osteotomes, trephines and drills included in the Osteosinus system have also benefited from this technology.

The Osteosinus concept facilitates sinus floor elevation and ensures that It is stress-free.

Clinical studies have indicated that an intact sinus membrane without tears is essential for successful grafting.

A sinus bone graft can either be harvested laterally (sinus lift) or crestally.

In many cases crestal sinus floor elevation completed with the Osteosinus is a practical alternative to a sinus lift.

Osteosinus, the most advanced technique in crestal sinus floor elevation

Indications for the Osteosinus it is mainly recommended for sinus floor elevation for placing one or two implants.

100 www.idisystem.eu

Page 101: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 101

THE OSTEOSINUS 1 SET

RL 33

RL 43

RL 53

RL 63

RL 73

RL 83

AL 33

AL 43

AL 53

AL 63

AL 73

AL 83

TL 33

TL 43

TL 53

TL 63

TL 73

TL 83

FL 33

FL 43

FL 53

FL 63

FL 73

FL 83

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

Ø 3 mm

LENGTH in mm

LENGTH in mm

LENGTH in mm

LENGTH in mm

P/N

P/N

P/N

P/N

DIAMETER

DIAMETER

DIAMETER

DIAMETER

3

3

3

3

4

4

4

4

5

5

5

5

7

7

7

7

6

6

6

6

8

8

8

8

Osteosinus (osteotome holder)

Diskosinus diameter 3 mm (bladed wheels for enlarging the bone base)

Osteosinus monobloc

Surgical stand

Base plate

P/N OST 1

P/N D3

P/N OSTM

P/N PLS

P/N BIC 1

6 Rectisinus (straight osteotome with colour-coded depth stop)

6 Angulosinus (angled osteotome with colour-coded depth stop)

6 Trepanosinus (trephine drill with colour-coded depth stop)

6 Forsinus (drill with colour-coded depth stop)

Important: The instruments with a 3 mm diameter are used for standard implants (3,5 to 4,4 mm Ø).

OST

EOSI

NUS

Page 102: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu

OSTEOSINUSThe Osteosinus is used for attaching a straight or angled osteotome depending on the operating site.

After assembling the osteotome, use the slide mallet to compact the bone.

Removable slide mallet

Can be dismantled

Shock absorber

Locking ring for the osteotome

102

Page 103: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 103

RECTISINUS

ANGULOSINUS

This set contains six straight osteotomes with a colour-coded depth stop, Ø 3 mm, length 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, 8 mm.

Insert the Rectisinus into the osteotome, position the guide in the operating site and compact the bone using the slide mallet.

This set contains six angled osteotomes with a colour-coded depth stop, Ø 3 mm, length 3-4-5-6-7 and 8 mm.

Insert the angulosinus into the osteotome, position the guide in the operating site and compact the bone using the slide mallet.

Depth stop limits the insertion depth of the osteotome

Depth stop limits the insertion depth of the osteotome

Colour coding for the depth

stop length

Colour coding for the depth

stop length

Colour coding for the

diameter

Colour coding for the

diameter

Guide for positioning the

osteotome

Guide for positioning the

osteotome

LENGTH

LENGTH

COLOR

COLOR

3

3

4

4

5

5

6

6

7

7

8

8

Lengths and colour-coded table for a 3 mm Ø

Lengths and colour-coded table for a 3 mm Ø

OST

EOSI

NUS

Page 104: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu

FORSINUS

TREPANOSINUS

This set contains six drills with a bone-harvesting channel and colour-coded depth stop, Ø 3 mm, length 3mm, 4 mm, 5mm, 6mm, 7mm, 8mm.

Use the drill at 70rpm without water cooling.

This set contains six trephines with a colour-coded depth stop, Ø 3 mm, length 3 mm, 4 mm, 5 mm, 6 mm, 7 mm and 8 mm.

Use the trephine at 70 rpm without water cooling.

Depth stop limits the insertion depth of the osteotome

Colour coding for the depth

stop length

Colour coding for the

diameter

Bone-harvesting

channel3

3

4

4

5

5

6

6

7

7

8

8

Lengths and colour-coded table for a 3 mm Ø

Lengths and colour-coded table for a 3 mm Ø

Depth stop limits the insertion depth of the osteotome

Colour coding for the depth stop length

Colour coding for the diameter

Window for extracting the bone cylinder

104

LENGTH

COLOR

LENGTH

COLOR

Page 105: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 105

OST

EOSI

NUS

DISKOSINUSThis set contains a small bladed wheel, Ø 3 mm (red ring)

The wheel is used after the Forsinus drill with the same diameter. Using a circular movement the bladed wheel enlarges the bone base below the sinus and provides it which increased resilience when using the osteotome.

Colour coding for the

diameter

Locking ring for the osteotome

1 2

5

3

6

4

Page 106: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu

TECHNIQUE BY USING THE TREPANOSINUS

Select a suitable section on the X-ray of the implant site and measure the bone availability (here: 8 mm).

Fill the cavity with the filler material.

Remove the trephine.

Place the implant after compacting approx. 2 cubic centimeters of the filler material.

Use a 7 mm long trephine Trepanosinus (red ring on top) with a bone availability of 8 mm.

Continue compacting the bone. The filler material gradually elevates the sinus membrane.

Depending on the composition of the operating site, select a straight or angled 8 mm long Osteosinus (yellow ring on top), attach it and use it to compact the bone cylinder. Sometimes because of a very resistant bone, it is necessary to start compacting with a surgical hammer.

Allow a healing period of approx. 8 months during which osseointegration is completed.

1

5

2

6

3

7

4

8

NB: we recommend checking osseointegration with a scanner before loading the implant.

8mm

106

Page 107: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 107

TECHNIQUE BY USING THE FORSINUS

Select a suitable section on the X-ray of the implant site and measure the bone availability (here: 7 mm)

Attach a 7 mm long osteotome (red ring on top) to the Osteosinus and use the instruments to compact the bone. Sometimes in front of a very resistant bone, it is necessary to start compacting with a surgical hammer.

Use the diskosinus

bladed wheel, rotating it slowly with a circular movement, to enlarge the bone base below the sinus and provide it which increased resilience.

Then place the implant.

Use the 6 mm long forsinus drill (red ring on top) with a bone availability of 7 mm.

Repeat the procedure until 1,5 to 2 cubic centimeters of filler material has been inserted. This gently elevates the sinus membrane without tearing it.

Fill the cavity with filler material.

Allow a healing period of approx 8 months during which osseointegration is completed.

1

5

2

6

3

7

4

8

NB: we recommend checking osseointegration with a scanner before loading the implant.

7mm

OST

ÉOSI

NUS

Page 108: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

ACCESSORIES & INSTRUMENTS

www.idisystem.eu

Ridge spreading condensing

Trephines

- 4 ridge spreaders with gradual diameters : 1,5 – 2 – 2,5 and 3 mm (on the lower edge) 2 – 2.3 – 3.4 and 3.9 mm (under the depth stop)

- Length: 20 mm, round edge- Colour coding for safety purpose - To set all types of implants to 4 mm diameter- Avoid the use of sharp drills on very narrow sites (the periodontal ligament is respected)- For lateral or vertical condensation- Gradual insertion (maximum 5 rpm) always with a 1/64 contra-angle.

Very sharp trephines in surgical stainless steel for bone explantation.Equipped with depth stops and lateral windows for an easy clearing of the recovered bone.

1,5 mm (white)P/N EX15

3,0 mm (green)P/N EX30

2,0 mm (yellow)P/N EX20

2,5 mm (red)P/N EX23

TL 33TL 43TL 53TL 63TL 73TL 83

TL 34TL 44TL 54TL 64TL 74TL 84

Ø 3 mmØ 3 mmØ 3 mmØ 3 mmØ 3 mmØ 3 mm

Ø 4 mmØ 4 mmØ 4 mmØ 4 mmØ 4 mmØ 4 mm

LENGTH in mm

P/NDIAMETER

3

3

4

4

5

5

7

7

6

6

8

8

Depth stop to limit the depth of drilling

Colour coding for the depth stop length

Colour coding for the diameter

Window for extracting the bone cylinder

108

Page 109: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

FOR MORSE TAPER AND HEXAGONAL CONNECTION

AC

CE

SS

OR

IES

&

INS

TR

UM

EN

TS

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

trac

tual

pic

ture

s

IDI IMPLANTS DIFFUSION INTERNATIONAL 109

Ratchets

Thread taps

Screwdrivers

Instruments

Bone thread tap (Ø 4 mm) P/N TAR 4

RatchetP/N 415

Ratchet + central part P/N 414

central partP/N 416

Bone thread tap (Ø 5 mm) P/N TAR 5

Bone thread tap(Ø 6 mm) P/N TAR 6

Manual thread tap, hardened stainless steel

P/N TAR M2

Manual screwdriver to screw the implant

P/N 0846

Hex-tipped screwdriver, short

P/N 0046

Hex-tipped screwdriver, long

P/N 0146

Screwdriver for relating instruments (long model)

P/N 0114

Screwdriver for relating instruments (short model)

P/N 0014

Instruments with dental shank, square-tipped instrument (short)

P/N 1014

Instruments with dental shank, square-tipped instrument (long)

Instruments with dental shank, hex-tipped instrument (short)

P/N 1114 P/N 1046

Instruments with dental shank, hex-tipped instrument (long)

P/N 1146 P/N 406

Instrument extension

P/N 403 ML P/N 403 M

Square-tipped screwdriver, long, width 1,4mm, for closing cap and healing caps*

Square-tipped screwdriver, short, width 1,4mm, for closing cap and healing caps* P/N 405 ML P/N 405 M

Square-tipped screwdriver, long, width 0,85mm, for impression copyings**

Square-tipped screwdriver, short, width 0,85mm, for impression copyings**

*Screwdriver for contra-angle P/N 403. ** Screwdriver for contra-angle P/N 405.

P/N 0148

Abutment remover for tapered implants (IDCAM® and IDALL® product lines)

Page 110: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

www.idisystem.eu

PACKAGING FOR IMPLANTS IDI

A DOUBLE STERILE PACKAGING

Method 1: Pick up the implant with a contra-angle

Method 2: Pick up the implant

manually

PressPress

RemoveRemove

1

11

22

2

3 4

110

Page 111: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

FOR MORSE TAPER AND HEXAGONAL CONNECTION

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

IMPLANTS DIFFUSION INTERNATIONAL

Non

con

tract

ual p

ictu

res

IDI IMPLANTS DIFFUSION INTERNATIONAL 111

PAC

KAG

ING

FO

R ID

I IM

PLA

NTS

Pick up the closing cap from the packaging

Pick up the healing cap from the lower part of the packaging

Take the packaging Insert the screwdriver

Rotate by 90° Remove

1

3

2

4

Take the packaging Insert the screwdriver

Rotate by 90° Remove

1

3

2

4

Cleaning and sterilisation instructions1. Clean the

instruments during 15 minutes in a decontamination bath with ultrasound

2. Rinse thoroughly3. Dry perfectly4. Sterilize for 90

minutes in a dry heat at 150° C or autoclave at 135° C for 20 minutes

Page 112: IMPLANTS DI FFUSION - Sinusmax · 2017-03-14 · Screwdriver with dental shank 25 Use the contra angle or the torque wrench* * Distortion of the screwdriver at 45Ncm to preserve the

23/25 rue Émile Zola - 93100 Montreuil - FranceTél. : +33 (0)1 48 70 70 48 – Fax : +33 (0)1 48 70 44 58www.idisystem.eu

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

SinceÊ1987

IMPLANTS DIFFUSION INTERNATIONAL

Photo credits: Agence G

reen and White &

IDI. Products featured in our catalogue are intended for healthcare professionals - February 2015 issue.

Print in the France. Any reproduction for all countries is strictly prohibited w

ithout the prior written perm

ission of the IDI com

pany. Non contractual photos and illustrations.