35
Dental Implant System Bone Level Tissue Level

IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

De

nta

l Im

pla

nt

Sy

ste

m

BoneLevel

TissueLevel

Page 2: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

Conte

nt

AGS Medikal and the Factory Research & Development 2Quality Warranty 6Clean Room Standards 7Production Line 7Quality Control Systems 8Sterilization Standards 8Product Tracking 9Packaging and Labelling 10Gold Standards 11Implant SystemDesign Specifications 14Hybrid Design 16Switch Platform 18Thread Design 19Structure without Micro Threads 19Exquisite Internal Structure and Conical Connection 20Surface Specifications Improved RBM Surface 22Edax Analysis 23Surface Treatment Analysis 23System General Specifications 24 Implance ImplantBone Level 26Tissue Level 28Surgical ProtocolFixture Drill Table 32Stopper Drills 37Smart Peg System 37ProsthesisHealing Abutments 39Bone LevelSolid System 40Couple System 42Octa System 44O-Ring System 46Tissue LevelSolid System 48Couple System 50Octa System 52O-Ring System 54Bar System 56Locator System 58Excellent Ball System 60Prosthetic Kit 62Abutment Planning Kit 63

Page 3: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

Implance Implant Systems continues to grow every day by developing innovative solutions.

Implance Dental Implant System,

is produced with high quality

standards by AGS Medikal with years

of experience and technological

investment. AGS Medikal has become

the market leader in Turkey in a short

time thanks to its production range,

product quality and service network.

Implance Implant System which has

a wide range of users in the world

markets, has continued to grow by

developing innovative solutions day by

day with its R&D studies and aims to

become one of the leading companies in

the world.

Page 4: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

AGS Medikal, has aimed to announce

Turkey's name to the world in dental

industry by introducing new systems and

products by means of applied researches,

tests and analyses.

Therefore, scientific projects where

most up-to-date research techniques and

specialties were applied extensively,

have been developed and proceeded in

cooperation with international institutes

and academic bodies in R&D studies.

AGS Medikal has consistently cooperated

with companies from developed countries

such as Switzerland, Italy and South Korea

in terms of production technologies.

AGS Medikal has given

great importance to

R&D studies based on customer

satisfaction and trust

principles in order to

produce innovative

solutions for industry

development and needs.

Page 5: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

PRODUCT QUALITYImplance Implant System devotes itself to continuous research and development; and consists of products with ergonomic design and compatible materials. All system components have user friendly, easily understandable and modular properties. All Implance products are controlled by expert teams at every stage starting from production planning to delivery and reach physicians with 100% quality warranty.

PRODUCT GUARANTEEImplance Implant System’s production is executed with the principle of perfection under modern conditions. Thus all Implance products have lifetime replacement warranty against breakage and loose screws under the correct indications.

SERVICE NETWORK AND DELIVERYImplance Dental Implant Systems headquartered in Istanbul, can reach Turkey and anywhere in the world through its dealers around the world. Our experienced sales team – specialists in their field, are committed to stand by your side whenever you need them throughout the sale and after sale phases, and whenever there is need for after sales services.

Our priority in the design, production and distribution of Implance brand is to ensure the top quality and safe product service. Procedures of a quality management system covering entire production process have been followed and production has been conducted in compliance with European and international regulations.

Fundamental tests and certificates following reviews include;• ISO 13485:2012• Medical Device Directive 93/42/EEC Appendix II.3

OUR QUALITY GUARANTEE

6 | 7

1984

Dental Implant System

All Implance-brand products have been packaged in the Clean Room that fulfills sterile environment features according to ISO Class 7* and air cleanliness classification standards according to ISO 14644-1.

The Clean Room is regularly subjected to validation according to ISO 14644-2 standard.

Surface, air and hand bio-contamination of clean room is monitored in periodical intervals according to ISO 14698-1 Bio-contamination Control Standard for Clean Rooms and Related Areas.

All Implance Dental Implant System products are manufactured in Swiss-made CNC machines with micron sensitivity.

Clean Room CNC machine

CLEAN ROOM STANDARDS

PRODUCTION LINE

ISO13485certified

* ISO Class 7:It is classification of air-cleanliness of clean room according to the air-borne particle concentration in areas where clean room technology is applied.

Page 6: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Quality Control Department controls all Implance products after-production with great attention to ensure they meet required quality and standards.

Products are cross-checked by different quality control officers with optic Mitutoyo-brand devices that have the highest technology in the world with high sensitivity of one per ten thousands (1/10,000). After cross-checking the out-of-tolerance products are eliminated.

The sterilization validation is conducted in accordance with EN ISO 11137-2. The gamma ray concentration obtained as a result of this validation is used for the gamma sterilization of the products according to EN ISO 11137-1 Sterilization of Health Care Products – Radiation.

8 | 9 Dental Implant System

Each product within Implance Implant System can be traced at every stage including production, stock management and after sales stages.

Every product package has barcode labels matching with the lot numbers created by ERP software system and thus follow-up process can be conducted flawlessly.

PRODUCT TRACEABILITYQUALITY CONTROLSYSTEMS

STERILIZATIONSTANDARDS Entire process stages from

production to delivery can be checked from the “Product Follow-up System”.

Page 7: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Implance Implants are packed in double sterile packages. This specifically developed packaging system protects the hygienic structure of the product perfectly and provides easy use for dentists with its smart-peg system.

The smart-peg implant holder provides extra convenience by directly transferring the implant with implant drivers without any intermediate transfer parts.

Each product package has a label containing all necessary information and coding such as type, length and color code of products.

Color coding and the associated diameters of products are classified as given below;

Labels on packages have all information and codes related to the product. Each product can be easily traced by the system with these codes.

Refer to usage instructions.

Single use only.

Catalog number.

Lot code.

Use before expiry date.

Date of production.

Producer.

Sterilized by irradiation.

Do not use damaged packages.

Temperature limitation.

10 | 11 Dental Implant System

PACKAGINGAND LABELING

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

Implance has become a brand which redefines standards with its production, quality and service understanding; taking the accepted standards to a higher level. Products classified according to high quality, defect-free production and service criterions are named as Gold Standard Products.

IMPLANCE DENTAL IMPLANT SYSTEM

GOLD STANDARDS

No screw loosening and breakage should occur with the originalsupport connection design.It should not create too much stress on neck part of bone to which implant is applied, with its special design and should not cause bone resorption in long term. It should be able to obtain primary stability in bones with different levels of hardness.It should have a perfectly roughened and cleaned surface. They must be sterilized according to correct standards in order to avoid osseointegration problems. It should have connection and superstructure diversity which can offer appropriate solutions against any type of indications.It should be sterilized according to correct standards in order to avoid osseointegration problems. Hygiene is very important not only for production but also for packaging. Implance Implant Systems provide perfect hygienic environments by means of the specifically developed double-sterile-packaging system.It is very important that the dentist can remove implant from package easily and apply it during operation. Implance smart-peg system offers ease of use during application. It is necessary to trace each product easily at every stage from production to delivery. Information with regards to the movement of the product until the delivery to destination can be listed in detail with Implance Product Tracking System.The slower the rotation of the drills, the lesser temperature accumulates in the bone. Self-stopper Implance drills can be used at an average rotational speed of 200 to 300 rpm.Every type of fixture and abutment must be compatible with each other. In Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3).An easy-understandable and applicable, user-friend surgical set in which products are classified according to color codes should exists.Implance Implant System sustains all gold standard features with an approach for 100% customer satisfaction.

FEATURES OF GOLD STANDARD PRODUCTS

Page 8: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

Implance Implant System with its

Bone Level and Tissue Level implant

alternatives has a wide product range

of products appropriate for different

indications. With surface and design

features at Gold standards, the system

is bone-friendly with its perfect quality

and is user-friendly with the easy use of

surgical set.

I M P L A N TS Y S T E M

BoneLevel

TissueLevel

Page 9: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

TissueLevel

ø3.7 ø4.3ø4.3-LO6 ø4.8-LO6 ø4.8 ø5.5

14 | 15 Dental Implant System

BoneLevel

DESIGNFEATURES

More hygienic implant neck area along with neck area cleaned from Micro threads ensures extra safety on the neck area.

1 1

1 1

2 2

3 3

3 3

Hybrid design is the ideal combination of straight and tapered designs.

New RBM surface with improved surface features.

Transgingival form which does not

allow colonization of bacterial plaque and

has no retention area and has strengthened

implant - abutment connection.

Self - cutting feature.

Groove design which does not

transfer stress to the bone.

2 2

4 4

5 5

5 56 6

6 6

4 4

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

More hygienic implant neck area along with neck area cleaned from Micro threads ensures extra safety on the neck area.

Hybrid design is the ideal combination of straight and tapered designs.

New RBM surface with improved surface features.

Switch platform; protects the cervical

bone by moving implant and abutment connection away from

the bone surface.

Self - cutting feature.

Groove design which does not

transfer stress to the bone.

Page 10: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

HybridDesign

Contact surfaces of cylindrical implants are larger than

those of conic implants; however there are problems about

finding its own way in the cavity drilled. On the other side,

conical implants can, although they have smaller surface

area, can easily find their way and advance in the cavity

drilled. The hybrid design implant has advantages of both

designs and is rather successful in finding its own way in

the cavity drilled because its apical is conical and it has

larger surface area and contact surface because its neck

area is cylindrical.

In conical implants, compression stress coming from the

bottom accumulates around the neck area of the bone

because groove diameter increases towards the neck area

this can cause neck resorption in the long term. The flat

forms of cylindrical implants and minimum use of micro

threads lowers neck compression and stress; however this

can result in difficulties to reach primary stability on bones

with low density.

On the other hand, hybrid implants have the ideal design

with cylindrical neck area and tapered apical. Therefore,

hybrid implants do not cause compression and stress and

bone loss which may arise from compression on the neck

area in long term.

Furthermore, it will be easy to reach primary stability even

on bones with low density due to their groove structure.

HYBRID DESIGNIt is an ideal combination of cylindrical (straight) and conical (tapered) implant designs.

Homogenous stress dispersion on the implant neck area.

3D model of implant

Straightform

Taperedform

HYBRID DESIGN STRESS ANALYSIS

Virtual model obtained from real patient's CT images.

Literature indicating stress analysesFinite element analysis of 3 dental implant designs at different straight/tapered ratios. International Journal of Oral and Maxillofacial Surgery, Volume 40, Issue 10, October 2011, Page 1138.

3D model of abutment

No stress or tensile is observed on the abutment screw.

Section view indicating stress and tensile dispersion of 3D model.

101N of horizontal and vertical force applied on implant surface.

101N

101N

142,5 N

Porcelain

Titanium

Corticalbone

Cancellousbone

Page 11: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

One of the biggest problems for Bone Level implants is the connection between implant and abutment and micro-gaps which can be formed there. Bacteria can grow in these gaps and thus can cause serious problems for the patient. Implance Implants have Switch Platform system which protects cervical bone by moving the connection between implant and abutment away from bone surface.

18 | 19

It’s a common mistake to think that micro grooves diminish stress on the neck area. There are no micro threads on neck area of Implance Implants and this feature provides many periodontologic advantages for users and physicians.

Bacterial plaque can colonize in micro threads more easily. Bone resorption risk at the neck will decrease in the implant design without micro threads because colonization of bacterial plaque will be lesser if bone does not cover the implant neck completely.

THREAD DESIGN

MICRO THREADLESS STRUCTURE

SWITCH PLATFORMImplance Implants have a thread design which does not transfer stress to the bone.

It has cutting edges and self cutting feature which provide ideal primary stability on every type of bone without transferring stress to the bone thanks to its semi-aggressive groove design.

Dental Implant System

Butt-jointimplant

PlatformSwitchimplant

Implance Implants with Switch Platform System are safer against bacteria and more hygienic; and have a longer life.

Page 12: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

The impeccable internal structure of Implance Implant System ensures excellent compatibility between the abutment and implant connection while no micro-gap is formed. This feature makes Implance implants longer-lasting and helps avoid breaking or loosening screws.

A more durable implant – abutment connection is provided by means of a 11° angled conical connection and morse taper, therefore abutment and superstructure will be much more durable and longer-lasting.

20 | 21 Dental Implant System

IMPECCABLE INTERNAL STRUCTURE AND CONICAL CONNECTION

SURFACESPECIFICATIONS

Implance Implants have perfectly

roughened and cleaned surfaces which

are perfectly compatible with the bone

morphology.

X 80SEM image of ø 3.7x8 mm internal section

Intra-Implant groove design

Page 13: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

The new RBM surface ensures faster and better osseointegration quality and complies with bone morphology perfectly.

22 | 23Dental Implant System

IMPROVED RBM SURFACERESORBABLE BLASTING MEDIA

X 250

X 5,000

X 50

X 2,500

Internal section of the fixture Exquisite labor with high sensitivity in accordance with international standards

According to results of the EDAX analysis, no foreign substance that can effect osseointegration negatively, exists on surface of Implance implants. which. The results are better than the acceptable values.

The new RBM surface ensures faster and better osseointegration quality and complies with bone morphology perfectly.

Edax Analysis

Surface Roughness Analysis

Page 14: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

IMPLANCEIMPLANTS

BoneLevel

TissueLevel

Implance Implant Systemsoffer extra ease of use for physicians with the easy and understandable system features.

A rich range of

superstructure

and laboratory

components

Practical surgical

set multi-stoppers

Lesser bone loss

due to hybrid

design

Sharp drills which

can be used at an

average of 200 and

300 rpm

Different abutment

options according

to different gingival

heights

Every abutment

can be used with

all fixtures of each

diameter.

User friendly

System features

Page 15: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

26 | 27 Dental Implant System

BONE LEVEL IMPLANT

ADVANTAGESSince the neck region of implant is at the bone level, grey-metallic color of the titanium can be hidden better, therefore no aesthetical problem occurs.

In situations where bone thickness is less in molar area, selecting an implant with thin diameters is mandatory. While working with the superstructure, a more accurate prosthetic gingival profile can be prepared for a molar tooth by using a wide diameter healing abutment and permanent abutment.

Bone level implant is more advantageous if the implant is intended to be fit in submerged position.

ø3.3 Length

8.0 mm10.0 mm12.0 mm14.0 mm

Product Code

BMFSR3308BMFSR3310BMFSR3312BMFSR3314

ø3.7 Length

8.0 mm10.0 mm12.0 mm14.0 mm

BFHR3708BFHR3710BFHR3712BFHR3714

ø4.3 Length

8.0 mm10.0 mm12.0 mm14.0 mm

BFHR4308BFHR4310BFHR4312BFHR4314

ø4.8 Length

8.0 mm10.0 mm12.0 mm14.0 mm

BFHR4808BFHR4810BFHR4812BFHR4814

ø5.5

ø4.7

ø5.5 Length

8.0 mm10.0 mm12.0 mm

BWFHR5508BWFHR5510BWFHR5512

ø3.3

ø2.65

ø3.7

ø3.15

ø4.3

ø3.55

ø4.8

ø4.0

Product Code

Product Code

Product Code

Product Code

Page 16: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

28 | 29 Dental Implant System

TISSUE LEVEL IMPLANT

ADVANTAGESIt significantly minimizes the irritation which can be formed in the gingiva around implant during removing and replacing the abutments in the superstructure fittings.

Implant-abutment connections are stronger compared to bone level implants.

Bone level implants with switch-platform avoid bone irritation and bone loss by moving the implant - abutment junction away from the bone surface. It is more ideal for the bone at the neck in tissue level implants because there is no connection almost up to gingival upper limit.

It is advantageous for immediate implant applications during tooth extraction. While ensuring primary fixation of implant in the conical extraction socket, socket inlet is covered better since neck area of the implant expanded.

In immediate implant applications, since the implant part coinciding with extraction socket inlet is a smooth surface, this area shall be more hygienic against bacterial plaque colonization after extraction.

Cortical bone wrapping the implant is protected better by the implant neck due to the expanding form of implant neck area.

It has a design which can be used safely for long years.

Tissue level implants are usually preferred for single step surgical applications.

Utmost attention should be paid while applying Tissue level implant for patients who have thin keratinized mucosa in the anterior region. Otherwise, we can confront with titanium color as an esthetical problem. For this reason, it is necessary to plan with great care for gummy - smile patients.

2.65

2.65

2.65

2.65

ø4.8

ø3.15

ø3.7 Length

8.0 mm10.0 mm12.0 mm14.0 mm

Product Code

TFHR3708TFHR3710TFHR3712TFHR3714

ø4.8

ø3.55

ø4.3 Length

8.0 mm10.0 mm12.0 mm14.0 mm

TFHR4308TFHR4310TFHR4312TFHR4314

ø4.8

ø4.0

ø4.8 Length

8.0 mm10.0 mm12.0 mm14.0 mm

TFHR4808TFHR4810TFHR4812TFHR4814

ø4.3

ø3.55

ø4.3 Length

4.0 mm5.0 mm6.0 mm

TFSR4304TFSR4305TFSR4306

ø4.8 Length

4.0 mm5.0 mm6.0 mm

TFSR4804TFSR4805TFSR4806

2.65

ø4.8

ø4.0

ø5.5 Length

8.0 mm10.0 mm12.0 mm

TWFHR5508TWFHR5510TWFHR5512

2.65

ø6.0

ø4.7

ø5.5 Length

4.0 mm5.0 mm6.0 mm

TWFSR5504TWFSR5505TWFSR5506

2.65

ø6.0

ø4.7

Product Code

Product Code

Product CodeProduct Code

Product Code

Product Code

Page 17: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant System

Implance Surgical Protocol System

offers a common surgical set for any

diameter of Bone Level and Tissue Level

implants. The surgical kit provides extra

convenience for the users since it has

multi-stoppers and is classified with

color codes.

Other advantages offered to the users

include steel dishes, torque ratchets and

neck drills for all diameters.

S U R G I C A LPROTOCOL

Page 18: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

32 | 33 Dental Implant System

IMPLANCE BONE / TISSUE LEVEL FIXTURE DRILL TABLE

ø3.3Fixture

ø3.7Fixture

D1 BonePointdrill → → →→ →→2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

3.7 Neck drill

3.7 Fixture

D2-3 BonePointdrill → → →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

3.7 Fixture

D4 BonePointdrill → → →→2.2

drill3.3

Fixture drill

Pilotdrill

3.7 Fixture

D1 BonePointdrill → → →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.3Neck drill

3.3 Fixture

D2-3 BonePointdrill → → →→2.2

drill3.3

Fixture drill

Pilotdrill

3.3 Fixture

D4 BonePointdrill → → →→2.2

drill3.3

Fixture drill

Pilotdrill

3.3 Fixture

Page 19: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

34 | 35 Dental Implant System

ø4.3Fixture

ø4.8Fixture

D1 BonePointdrill → → →→ → →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8Fixture

drill

4.8 Neck drill

4.8 Fixture

D2-3 BonePointdrill → → →→ →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8Fixture

drill

4.8 Fixture

D4 BonePointdrill → → →→ →→2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8 Fixture

D1 BonePointdrill → → →→ →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.3 Neck drill

4.3 Fixture

D2-3 BonePointdrill → → →→ →→2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.3 Fixture

D4 BonePointdrill → → →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

Page 20: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

36 | 37 Dental Implant System

Self-stopper drills offer great convenience to the users and eliminate the possibility of making a mistake.

Implance drills can operate at 200 to 300 rpm rotational speeds; therefore, cell necrosis which is caused from excessive heat can be avoided. Another advantage of operating in a low rotational speed is that the extracted bone powders can be used in a healthy manner for the patient’s treatment later.

Implance drills are longer-lasting. Implance drills can be used for about 300 times and this is also another advantage offered to the physicians.

Implance Smart-Peg System makes it easier to remove implants from their boxes and fitting into the cavity. This offers great convenience to the dentists during operation.

SELF-STOPPER DRILLS

SMART PEG SYSTEM

ø5.5Fixture

D1 BonePointdrill → → →→ → →→ → →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8Fixture

drill

5.5Fixture

drill

5.5 Neck drill

5.5 Fixture

D2-3 BonePointdrill → → →→ → →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8Fixture

drill

5.5Fixture

drill

5.5 Fixture

D4 BonePointdrill → → →→ →→ →2.2

drill3.3

Fixture drill

Pilotdrill

3.7Fixture

drill

4.3Fixture

drill

4.8Fixture

drill

5.5 Fixture

Page 21: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

38 | 39 Dental Implant System

PROSTHESIS It is necessary to use the healing abutment with appropriate height and diameter corresponding with the abutment type to be used depending on the gingival height and crown diameter to be applied. If an abutment having smaller gingival height than the healing abutment is to be used, problems will occur in application since gingival opening will be thinner than the neck of abutment.

HEALING ABUTMENTS

It is a temporary plastic abutment that you can use immediately after surgery, particularly in the aesthetic zone to customize the temporary prosthesis.

TEMPORARY ABUTMENT

HEALING ABUTMENTSBONE LEVEL

ø4.51 mm 2 mm 3 mm 4 mm 5 mm

BHA4510 BHA4520 BHA4530 BHA4540 BHA4550

ø5.5 BHA5510 BHA5520 BHA5530 BHA5540 BHA5550

ø6.5 BHA6510 BHA6520 BHA6530 BHA6540 BHA6550

ø3.5 2.5 mm 3.5 mm 5 mm 7 mm

BMHA3725 BMHA3735 BMHA3750 BMHA3770ø3.3

implantiçindir.

HEALING ABUTMENTSTISSUE LEVEL

ø3.73 mm 4 mm 5.5 mm

THA30 THA40 THA55

ø6.4 THAW30 THAW40 THAW55

TEMPORARY ABUTMENTSBONE LEVEL

ø4.5 BTA45

ø5.5 BTA55

CODE

Page 22: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

40 | 41 Dental Implant System

SOLID SYSTEM BONE LEVELSOLID ABUTMENTS

ø3.51 mm 2 mm 3 mm 4 mm 5 mm

BMSA3710 BMSA3720 BMSA3730 BMSA3740 BMSA3750

ø4.5 BSA4510 BSA4520 BSA4530 BSA4540 BSA4550

ø5.5ø6.5

BSA5510

BSA6510

BSA5520

BSA6520

BSA5530

BSA6530

BSA5540

BSA6540

BSA5550

BSA6550

only for ø3.3 implant

SOLID PLASTIC COPING

ø3.5BRIDGE CROWN

BMSAPIC37b BMSAPIC37c

ø4.5 BSAPIC45b BSAPIC45c

ø5.5ø6.5

BSAPIC55b

BSAPIC65b

BSAPIC55c

BSAPIC65c

only for ø3.3 implant

SOLID LAB ANALOG

ø3.5CODE

BMSALA37

ø4.5 BSALA45

ø5.5ø6.5

BSALA55

BSALA65

only for ø3.3 implant

SOLID ABUTMENT CAP

ø3.5CODE

BMSACap37

ø5.1 BSACap45

ø5.8ø6.8

BSACap55

BSACap65

only for ø3.3 implant

SOLID ABUTMENTIMPRESSION CAP

ø3.5CODE

BMSAICap37

ø4.5 BSAICap45

ø5.5ø6.5

BSAICap55

BSAICap65

only for ø3.3 implant

BoneLevel

DESCRIPTION

FIXTURE

PLASTIC COPING1 Single2 Bridge

ABUTMENT1 Solid2 Cap

1 Closing Screw2 Healing Abutment

Ratchet Driver

1.2Hex Driver

SolidDriver

LAB ANALOG

IMPRESSION CAP

p

p

p

p

p

TOOLFLOW

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

1.2Hex Driver

1.2Hex Driver

1 2

21

21

Page 23: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

42 | 43 Dental Implant System

COUPLE SYSTEM BONE LEVEL COUPLE ABUTMENTS

ø3.51 mm 2 mm 3 mm 4 mm 5 mm

BMCA3710 BMCA3720 BMCA3730 BMCA3740 BMCA3750

ø4.5 BCA4510 BCA4520 BCA4530 BCA4540 BCA4550

ø5.5ø6.5

BCA5510

BCA6510

BCA5520

BCA6520

BCA5530

BCA6530

BCA5540

BCA6540

BCA5550

BCA6550

only for ø3.3 implant

ø3.51 mm 2 mm 3 mm 4 mm 5 mm

BMCAN3710 BMCAN3720 BMCAN3730 BMCAN3740 BMCAN3750

ø4.5 BCAN4510 BCAN4520 BCAN4530 BCAN4540 BCAN4550

ø5.5ø6.5

BCAN5510

BCAN6510

BCAN5520

BCAN6520

BCAN5530

BCAN6530

BCAN5540

BCAN6540

BCAN5550

BCAN6550

only for ø3.3 implant

COUPLE ABUTMENT NON-HEX

ANGLED ABUTMENT ANGLED ABUTMENT NON-HEX

ø4.5 ø4.52 mm (15°&25°) 2 mm (15°&25°)4 mm (15°&25°) 4 mm (15°&25°)

BAA45152 BAAN45152

BAA55152 BAAN55152

BAA65152 BAAN65152

BAA45252 BAAN45252

BAA55252 BAAN55252

BAA65252 BAAN65252

BAA45154 BAAN45154

BAA55154 BAAN55154

BAA65154 BAAN65154

BAA45254 BAAN45254

BAA55254 BAAN55254

BAA65254 BAAN65254

ø5.5 ø5.5

ø6.5 ø6.5

ø3.5 ø3.51 mm (15°) 1 mm (15°)2 mm (15°) 2 mm (15°)4 mm (15°) 4 mm (15°)

BMAA37151 BMAAN37151BMAA37152 BMAAN37152BMAA37154 BMAAN37154only

for ø3.3 implant

only for ø3.3 implant

ø3.5HEX

BMMA37

BMA45ø4.5ø5.5 BMA55

NON-HEX

BMMAN37

BMAN45

BMAN55

MULTI ABUTMENTHEX - NON HEX IMPRESSION COPING PICK UP

HEX - NON HEX

ø4.5

ø3.5HEX NON-HEX

BICP45L

BMICP37L

BICP55L

BICP65L

BICP45S

BMICP37S

BICP55S

BICP65S

BICPN45L

BMICPN37L

BICPN55LBICPN45S

BMICPN37S

BICPN55SBICPN65LBICPN55S

ø5.5

ø6.5

only for ø3.3 implant

only for ø3.3 implant

IMPRESSION COPING TRANSFERHEX - NON HEX

ø4.5

ø3.5HEX NON-HEX

BICT45L

BMICT37L

BICT55L

BICT65L

BICT45S

BMICT37S

BICT55S

BICT65S

BICTN45L

BMICTN37L

BICTN55LBICTN45S

BMICTN37S

BICTN55SBICTN65LBICTN55S

ø5.5

ø6.5

only for ø3.3 implant.

BMFLA

BFLA

FIXTURE LAB ANALOG

BoneLevel

DESCRIPTION

FIXTURE

ABUTMENT1 Couple2 Multi3 Angled

ABUTMENT1 Pick-up2 Transfer

1 Closing Screw2 Healing Abutment

Ratchet Driver

1.2Hex Driver

Hex

HexHex 15°

Hex Non Hex

Non HexNon Hex 25°

Non Hex

SCREW

LAB ANALOG

p

p

p

p

p

TOOLFLOW

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

1.2Hex Driver

1.2Hex Driver

2

2

1

1

1 2 3

Page 24: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

44 | 45 Dental Implant System

OCTA SYSTEM BONE LEVEL OCTA ABUTMENTS

OCTA SYSTEM IMPRESSIONCOPING PICK UP

OCTA SYSTEM IMPRESSIONCOPING TRANSFER

OCTA ABUTMENTHEALING CAP

OCTA ABUTMENTLAB ANALOG

ø3.5

ø5.5

ø5.0

ø4.9

ø4.8

1 mm

HEX

HEX

CODE

CODE

2 mm

NON-HEX

NON-HEX

3 mm 4 mm 5 mm

BMOA10

BOA10

ICOAP

ICOAT

OAHCap

OALA

BMOA20

BOA20

ICOAPN

ICOATN

BMOA30

BOA30

BMOA40

BOA40

BMOA50

BOA50

OCTA ABUTMENT PLASTIC CYLINDER

OCTA N-OCTA

OAPICy OAPICyN

BoneLevel

DESCRIPTION

FIXTURE

IMPRESSION COPING1 Pick-up2 Transfer

SUB OCTA ABUTMENT1 Octa Healing Cap2 Octa Abutment

1 Closing Screw2 Healing Abutment

Ratchet Driver

Octa Driver

SCREW

LAB ANALOG

LAB CYLINDER

p

p

p

p

p

p

TOOLFLOW

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

1.2 Hex Driver

1.2 Hex Driver

2

2

2

1

1

1

Octa N-Octa

ø4.8

only for ø3.3 implant

Page 25: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

46 | 47 Dental Implant System

O-RING SYSTEM BONE LEVELO-RING ABUTMENTS

ø3.42

ø2.9

0.5 mm 1 mm 2 mm 3 mm 4 mm 6 mm

BORA05

BMORA05

– – – –

– – – – –

ø4.50

ø3.5

– –

– – – –

BORA10

BMORA20

BORA20 BORA30 BORA40 BORA60

BMORA40

O-RINGLAB ANALOG

CODE

ORLA

BoneLevel

DESCRIPTION

FIXTURE

1 O-Ring2 O-Ring Retainer

1 Closing Screw2 Healing Abutment

Ratchet Driver

O-RING LAB ANALOG

O-RING ABUTMENT

p

p

p

p

TOOLFLOW

ø3.3 ø3.7 ø4.3 ø4.8 ø5.5

1.2 Hex Driver

O-Ring Driver

1 2

21

only for ø3.3 implant

RETAINER RETAINER RETAINER

CODE CODE CODE

ORR ORR-C ORR-O

0°7°14°

DIRECTIONAL RINGS

INSERTDRIVER

Page 26: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

48 | 49 Dental Implant System

SOLID SYSTEM TISSUE LEVELSOLID ABUTMENTS

ø3.54 mm 5 mm 5.5 mm

TSA40 – TSA55

ø4.3 TSAL40 TSAL50 –

7 mm

TSA70

TSAL70

ø6.0 TSALLA40

SOLID ABUTMENT LAB ANALOG

ø4.84 mm 5.5 mm 7 mm

TSALA40 TSALA55

TSALLA55

TSALA70

TSALLA70

SOLID ABUTMENT CAP

ø5.54 mm 5.5 mm 7 mm

TSACap40 TSACap55 TSACap70

SOLID PLASTIC COPING

ø5.3CROWN BRIDGE

TSAPICc TSAPICb

CODE

TSAICap

SOLID ABUTMENTIMPRESSION CAP

CODE

TSAPoCy

SOLID ABUTMENTPOSITIONING CYLINDER

TissueLevel

DESCRIPTION

FIXTURE

PLASTIC COPING1 Crown2 Bridge

LAB ANALOG1 Shoulder Analog & Pin2 Lab Analog

ABUTMENT1 Solid2 Cap

1 Closing Screw2 Healing Abutment

Ratchet Driver

1.2Hex Driver

SolidDriver

IMPRESSION CAP

p

p

p

p

p

TOOLFLOW

ø4.3ø3.7 ø4.8-L06ø4.3-L06 ø4.8 ø5.5

1.2Hex Driver

1.2Hex Driver

1

1

2

2

21

21

Page 27: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

50 | 51 Dental Implant System

COUPLE SYSTEM TISSUE LEVEL COUPLE ABUTMENTS

ø5.21 mm 2 mm 3 mm 4 mm

TCA10 TCA20 TCA30 TCA40

ø6.4 TCAW10 TCAW20 TCAW30 TCAW40

COUPLE ABUTMENT NON-OCTA

ø5.21 mm 2 mm 3 mm 4 mm

TCAN10 TCAN20 TCAN30 TCAN40

ø6.4 TCAWN10 TCAWN20 TCAWN30 TCAWN40

ANGLED ABUTMENT

ø3.715° 25°

TAA15 TAA25

ø5.2OCTA NON-OCTA

TMA TMAN

MULTI ABUTMENTOCTA - NON OCTA

ø5.5ø6.4

OCTA NON-OCTA

TICP

TICPW

TICPN

TICPWN

IMPRESSION COPING PICK UPOCTA - NON OCTA

ø5.5OCTA NON-OCTA

TICT TICTN

IMPRESSION COPING TRANSFEROCTA - NON OCTA

ø4.8 TFLA

ø6.0 TFLLA

CODE

FIXTURE LAB ANALOG

TissueLevel

DESCRIPTION

FIXTURE

ABUTMENT1 Couple2 Multi3 Angled4 Synocta

IMPRESSION COPING1 Pick-up2 Transfer

1 Cover Screw2 Healing Abutment

1.2Hex Driver

Hex

HexHex Hex15°

Hex Non Hex

Non HexNon Hex Non Hex25°

Non Hex

SCREW

LAB ANALOG

TOOLFLOW

1.2Hex Driver

2

2

1

1

1 2 3 4

Ratchet Driverø4.3ø3.7 ø4.8-L06ø4.3-L06 ø4.8 ø5.5

1.2Hex Driver

p

p

p

p

p

ø3.56 mm

TSOA

SYNOCTAABUTMENT

ø3.56 mm

TSOAN

SYNOCTA ABUTMENTNON-OCTA

Page 28: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

52 | 53 Dental Implant System

OCTA SYSTEM TISSUE LEVEL

ø5.5

ø5.0

OCTALAB ANALOG

ø4.8CODE

OALA

OCTA ABUTMENT

CODE

TOAø3.5

OCTA ABUTMENT PLASTIC CYLINDER

OCTA NON-OCTA

OAPICy OAPICyN

TissueLevel

DESCRIPTION

FIXTURE

IMPRESSION COPING1 Pick-up2 Transfer

OCTA ABUTMENT

1 Cover Screw2 Healing Abutment

Octa Driver

SCREW

LAB ANALOG

LAB CYLINDER

p

p

p

p

p

p

TOOLFLOW

1.2 Hex Driver

1.2 Hex Driver

2

2

1

1

Octa N-Octa

Ratchet Driverø4.3ø3.7 ø4.8-L06ø4.3-L06 ø4.8 ø5.5

OCTA SYSTEM IMPRESSIONCOPING PICK UP

OCTA NON-OCTA

ICOAP ICOAPN

OCTA SYSTEM IMPRESSIONCOPING TRANSFER

OCTA NON-OCTA

ICOAT ICOATN

Page 29: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

54 | 55 Dental Implant System

O-RING SYSTEM TISSUE LEVELO-RING ABUTMENTS

ø3.50.5 mm 2 mm 4 mm

TORA05 TORA20 TORA40

O-RINGLAB ANALOG

CODE

ORLA

TissueLevel

DESCRIPTION

FIXTURE

1 O-Ring2 O-Ring Retainer

1 Closing Screw2 Healing Abutment

O-RING LAB ANALOG

O-RING ABUTMENT

p

p

p

p

TOOLFLOW

1.2 Hex Driver

O-Ring Driver

1 2

21

Ratchet Driverø4.3ø3.7 ø4.8-L06ø4.3-L06 ø4.8 ø5.5

RETAINER

CODE

ORR

RETAINER

CODE

ORR-C

RETAINER

CODE

ORR-O

0°7°14°

DIRECTIONAL RINGS

INSERTDRIVER

Page 30: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

56 | 57 Dental Implant System

BAR SYSTEM BONE / TISSUE LEVEL

BAR CLIP YELLOW / IBClip - yMedium Retention 1.8 Kg

BAR CLIP PINK / IBClip - pSoft Retention 1.2 Kg

BAR CLIP RED / IBClip - rExtra Soft Retention 0.8 Kg

BAR BURNOUT / IB - burnout

BAR POSITIONING / IBP - burnout

BAR HOUSING / IBH - burnout

TissueLevel

OCTA ABUTMENTPLASTIC CYLINDER

N-OCTA

OAPICyN

OCTA SYSTEM IMPRESSIONCOPING PICK UP

ø5.5HEX NON-HEX

ICOAP ICOAPN

OCTA SYSTEM IMPRESSIONCOPING TRANSFER

ø5.0HEX NON-HEX

ICOAT ICOATN

OCTA ABUTMENTHEALING CAP

ø4.9CODE

OAHCap

OCTA ABUTMENTLAB ANALOG

ø4.8CODE

OALA

BoneLevel

BONE LEVEL

OCTA SYSTEM IMPRESSIONCOPING PICK UP

ø5.5

OCTA SYSTEM IMPRESSIONCOPING TRANSFER

ø5.0OCTA

ICOAT

NON-OCTA

ICOATN

OCTA

ICOAP

NON-OCTA

ICOAPN

OCTALAB ANALOG

ø4.8CODE

OALA

OCTA ABUTMENT

CODE

TOAø3.5

OCTA ABUTMENTPLASTIC CYLINDER

NON-OCTA

OAPICyN

TISSUE LEVEL

OCTA ABUTMENTS

ø3.51 mm 2 mm 3 mm 4 mm 5 mm

BMOA10

BOA10

BMOA20

BOA20

BMOA30

BOA30

BMOA40

BOA40

BMOA50

BOA50ø4.8

only for ø3.3 implant

TOOLFORINSERTINGCLIP

KEYFORPARALLELOMETER

Page 31: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

58 | 59 Dental Implant System

LOCATOR SYSTEM BONE / TISSUE LEVEL

VIOLET CAPRigid Retention 2.7 Kg

CLEAR CAPStandard Retention 1.8 Kg

PINK CAPSoft Retention 1.2 Kg

YELLOW CAPExtra Soft Retention 0.6 Kg

BLACK CAPProcessing

LOCATOR LAB ANALOG

BONE LEVEL LOCATOR ABUTMENT

TISSUE LEVEL LOCATOR ABUTMENT

LOCATOR MATRIX / LMHt

TISSUE LEVEL LOCATOR LAB ANALOG

CODE

TLLA

BONE LEVEL MINI LOCATOR ABUTMENTS

ø3.31,5 mm 2,5 mm 3,5 mm 4,5 mm 5,5 mm 6,5 mm

BMLA15 BMLA25 BMLA35 BMLA45 BMLA55 BMLA65

BONE LEVEL MINI LOCATOR LAB ANALOG

CODE

BMLLA

BONE LEVEL LOCATOR LAB ANALOG

CODE

BLLA

ø3.86

BONE LEVEL LOCATOR ABUTMENTS

1,5 mm 2,5 mm 3,5 mm 4,5 mm 5,5 mm 6,5 mm

BLA15 BLA25 BLA35 BLA45 BLA55 BLA65

ø4.9

TISSUE LEVEL LOCATOR ABUTMENTS

1,5 mm 2,5 mm 3,5 mm 4,5 mm 5,5 mm 6,5 mm

TLA15 TLA25 TLA35 TLA45 TLA55 TLA65

only for ø3.3 implant

only for ø3.3 implant

Page 32: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

60 | 61 Dental Implant System

EXCELLENT BALL SYSTEM

EXCELLENT BALL IMPRESSION CAP / EBICap

EXCELLENT BALL LAB ANALOG / EBLA

EXCELLENT BALL RACHET DRIVER / EBRD

EXCELLENT BALL CONTRA ANGLE DRIVER / EBCAD

EXCELLENT BALL BLOCK OUT RING / EBBO-Ring

EXCELLENT BALL PATH GUIDE RING / EBPG-Ring

EXCELLENT BALL IMPRESSION SHEET / EBIS

EXCELLENT BALL OVERDENTURE CAP / EBOCap

BONE LEVEL EXCELLENT BALL ABUTMENT

TISSUE LEVEL EXCELLENT BALL ABUTMENT

BONE LEVEL

TISSUE LEVELEXCELLENT BALL ABUTMENT

ø3.50.5 mm 2 mm 4 mm

TEBA05 TEBA20 TEBA40

EXCELLENT BALL ABUTMENT

ø2.90.5 mm 1 mm 2 mm 3 mm 4 mm

BMBA05

BEBA05

BEBA10

BMEBA20

BEBA20

BEBA30

BMEBA40

BEBA40

5 mm 6 mm

BEBA50

BEBA60

ø3.5ø3.42

ø4.50

FunctionalityStructure for

distributing vertical and lateral pressure. (specially designed with combination of abutment and

housing)

Aesthetics

Excellent

aesthetics

achieved without

discoloration

of acrylic from

conventional

metal housing.

Flexibility

Allows up to

40 degrees

angulation

between implants

without loss of

retention force.

ReliabilityContact between the head of the abutment with

the ceramic balls within the

housing with minimal abrasion.

Page 33: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

62 | 63 Dental Implant System

Prosthetic Kit is a sterile kit specifically for the Prosthesis stage including a ratchet with torque and all the drivers that dentists might need during this stage. The kit includes all lengths of the drivers used for prosthesis in bone and tissue level implant systems, and different lengths of hex drivers necessary for the hand piece.

Implance prosthetic kit can be steam sterilized in autoclave with its special tray and case.

PROSTHETIC KIT

Abutment Planning Kit is an assistive tool for the dentists to choose the appropriate types of abutments to use. The kit includes identical titanium models for different dimensions and lengths of straight and angled abutments. This model assists the dentists in choosing the most appropriate abutment for the prosthesis planning stage; which reflects to a successful execution of the planned prosthetics.

Abutments are color coded for different types of implants:

- Abutments for 3.3 mini implants are gray,- Abutments for bone level implants are blue,- Abutments for tissue bone level implants are blue.

ABUTMENT PLANNING KIT

Page 34: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

Dental Implant Systemimplance.com

arka kapak içinde dosya cepi olacak

Page 35: IMPLANCE - Dental Implant System - Bone · 2017. 3. 7. · Implance Dental Implant System, every abutment is compatible with all fixtures with any diameters (except for Q 3.3). An

AGS Medikal Ürünleri İth. İhr. Tic. Ltd. Şti.

Mahmut Yesari Sok. No: 25

34718 Koşuyolu

İstanbul / Türkiye

T +90 216 546 00 78

F +90 216 546 00 79

implance.com