IMPERIAL ZINCSITE IMPROVEMENT PLANS
1031 EAST 103RD STREETSEC 14 - TWP 37 - RANGE 14
COOK COUNTYCHICAGO, ILLINOIS
DESCRIPTION
INDEX TO SHEETS
NO.
C-1C-2C-3C-4C-5C-6C-7C-8C-9C-10C-11
TITLE SHEETGENERAL NOTES & CONSTRUCTION SPECIFICATIONSEXISTING CONDITIONSDEMOLITION PLANGEOMETRY & PAVING PLANUTILITY PLANGRADING PLANEROSION CONTROL PLANCISTERN DISCHARGE PUMP DETAILS & SPECIFICATIONSCONSTRUCTION DETAILSCONSTRUCTION DETAILS
File
Nam
e:La
yout
:P:
\200
8\08
113
\Dra
win
gs\F
inal
Eng
inee
ring\
0811
3E-T
S-G
N-D
T.dw
g M
ar 0
6, 2
009
- 12
:06p
m01
-Titl
eje
rem
y-h
Plot
Dat
e:Pl
otte
d By
:
consulting engineersHAEGER ENGINEERING
land surveyors
RevisionDateNo.
Project Manager: Engineer: SheetDate: Project No.
C 2
009
Hae
ger
Engi
neer
ing,
LLC
TITLE SHEET
IMPERIAL ZINC1031 EAST 103RD STREET
CHICAGO, ILLINOIS
08113ETPP MRJ
11-14-08 C-1
1 02-02-09 Revised per DCAP Review2 02-19-09 Revised per Department of Water Management Review3 03-06-09 Revised per Department of Water Management Review
LEGEND
Proposed Symbol
Catch Basin
Inlet
Storm Sewer Manhole
Existing Symbol Description
Perforated Underdrain
Open Lid Frame & Grate
Closed Lid Frame & Lid
Utility Pole
Coniferous Tree
Brushline
Pavement Elevation
Sidewalk Elevation
Ground Elevation
Deciduous Tree
Swale
Contour Line
Curb & Gutter
Curb Elevation and Gutter Elevation
Pipe Bollard
Flagpole
Mailbox
Telephone Line
Cable TV Line
Traffic Signal
Mast Arm
Sign
Fence
Guy Wire
Telephone Pedestal
Telephone Manhole
Fire Hydrant
Electric Manhole
Power Line
Hand Hole
Light Pole
Valve Vault
Valve Box
Gas Valve
Gas Line
Headwall
Storm Sewer
Sanitary Sewer
Combined Sewer
Water Main
Area Drain
Clean Out
Soil Boring
Overflow
Flared End Section
Number of Parking Stalls
Handicapped Parking Stall
Well Head
Top of Retaining Wall Elevation
Bottom of Retaining Wall Elevation
Force Main
Overhead Utility Lines
Electrical Pedestal
Cable TV Pedestal
Guardrail
Sanitary Sewer Manhole
Retaining Wall
Know what's
R
LOCATION MAPNot To Scale
NSITE LOCATION
SITE BENCHMARKS
CCD BENCHMARKS
UTILITY CONTACTS
Reverse Gutter
Barrier Curb
Depressed Curbat ADA Ramp
Sheet Flow
Ridgeline
Detectable Warning
OWNER/ DEVELOPERImperial Zinc Corp.1031 East 103rd StreetChicago, IL 60628
Contact: David Kozintel: 773.264.5900 fax: 773.264.5910
ARCHITECTMcClellan Blakemore Architects
CIVIL ENGINEER / LAND SURVEYORHaeger Engineering300 South Wacker Drive, Suite 2435Chicago, IL 60606tel: 312.447.0525 fax: 312.447.0525Contact: Todd Shaffer
MEP ENGINEERReister Engineering, Inc.1440 21st StreetRockford, IL 61108tel: 815.227.0100 fax: 815.227.0300
GENERAL CONTRACTOR
1325 Sycamore Road, Suite 100DeKalb, IL 60115tel: 815.756.6369 fax: 815.756.9182
Rosenow Franzene Development
400 North First StreetRockford, IL 61107tel: 815.227.0023 fax: 815.227.0024
STRUCTURAL ENGINEER
tel: 630.966.0250 fax: 630.966.0255
Runde Engineering, Inc.
CONTACT LIST
Contact: Dave Franzene
Contact: Eric Blauert
Contact: Lowell Larson
39 West New York StreetAurora, IL 60506
Contact: Dan Runde
3
File
Nam
e:P:
\200
8\08
113
\Dra
win
gs\F
inal
Eng
inee
ring\
0811
3E-T
S-G
N-D
T.dw
g
consulting engineersHAEGER ENGINEERING
land surveyors
RevisionDateNo.
Project Manager: Engineer: SheetDate: Project No.
GENERAL NOTES &CONSTRUCTION SPECIFICATIONS
IMPERIAL ZINC1031 EAST 103RD STREET
CHICAGO, ILLINOIS
08113ETPP MRJ
11-14-08 C-2
NScale: 1" = 30'
File
Nam
e:La
yout
:P:
\20
08\0
8113
\Dra
win
gs\F
inal
Eng
inee
ring\
0811
3E-F
inal
Eng
.dw
g M
ar 0
6, 2
009
- 11
:30a
m08
-Ero
sion
Con
trol
jere
my-
hPl
ot D
ate:
Plot
ted
By:
consulting engineersHAEGER ENGINEERING
land surveyors
RevisionDateNo.
Project Manager: Engineer: SheetDate: Project No.
C 2
009
Hae
ger
Engi
neer
ing,
LLC
EROSION CONTROLPLAN
IMPERIAL ZINC1031 EAST 103RD STREET
CHICAGO, ILLINOIS
08113ETPP MRJ
11-14-08 C-8
2 02-19-09 Revised per Department of Water Management Review3 03-06-09 Revised per Department of Water Management Review
2
3
3
3
3