9
Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April 20, 2015

Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Embed Size (px)

Citation preview

Page 1: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 1

Impact of Cu/NonCu on MQXF Quench Protection

G. Ambrosio, V. Marinozzi, E. Todesco

Conductor Video Mtg. April 20, 2015

Page 2: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 2

Code and Parameters

• QLASA simulations by V. Marinozzi• MATPRO material properties• Methods and Material Properties validated by

comparison with LQ and HQ test data

PROTECTION PARAMETERSCurrent (kA) 16.5 / 17.5 /18.5 /20 /22

Lenght (m) 16.8Dump resistor (mΩ) 48.6 / 45.5 / 43.2 / 40.0 / 36.0

Voltage threshold (V) 0.1Validation Time (ms) 10

HF-IL PH delay time (ms) 18 / 15.5 / 13 / 7.5 / 5LF-IL PH delay time (ms) 18.5 / 16 / 13.5 / 8 / 5.5

HF-OL PH delay time (ms) 19.5 / 18 / 16.5 / 13 / 11.5LF-OL PH delay time (ms) 23 / 22.5 / 21 / 18 / 16.5

Dynamic effects on inductance no

Q1 and Q3 in series

Conservative assumption

Page 3: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 3

Hot Spot Temp. vs Cu/NonCu

0.8 0.85 0.9 0.95 1 1.05 1.1 1.15 1.2260270280290300310320330340350360

MQXF Hot Spot Temperature16.5 kA17.5 kA18.5 kA

Cu/NCu

Tem

pera

ture

[K]

Page 4: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 4

Extreme Case

After 16 independent heater circuits are lost

Page 5: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 5

Test of Q2 at I > 16.5 kA

PROTECTION PARAMETERSCurrent (kA) 18.5 /20

Lenght (m) 7.15Dump resistor (mΩ) 50

Voltage threshold (V) 0.1Validation Time (ms) 10

HF-IL PH delay time (ms) - pessimistic 12 / 8.5 LF-IL PH delay time (ms) - pessimistic 13 / 9.5

HF-OL PH delay time (ms) - pessimistic 16.5 / 14LF-OL PH delay time (ms) - pessimistic 21 / 18.5

HF-IL PH delay time (ms) - optimistic 7 / 4.5 LF-IL PH delay time (ms) - optimistic 7.5 / 5.5

HF-OL PH delay time (ms) - optimistic 10.5 / 9LF-OL PH delay time (ms) - optimistic 14 / 12.5

Dynamic effects on inductance yes

Three heaters have been deactivated in one coil

Validation + switch at VMTF: 1 ms

Page 6: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 6

Test of Q2 at I > 16.5 kA

Page 7: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 7

Test of Q2 at I > 16.5 kAat Test Facility

PROTECTION PARAMETERSCurrent (kA) 18.5 /20

Lenght (m) 7.15Dump resistor (mΩ) 50

Voltage threshold (V) 0.1Validation Time (ms) 2

HF-IL PH delay time (ms) - pessimistic 12 / 8.5 LF-IL PH delay time (ms) - pessimistic 13 / 9.5

HF-OL PH delay time (ms) - pessimistic 16.5 / 14LF-OL PH delay time (ms) - pessimistic 21 / 18.5

HF-IL PH delay time (ms) - optimistic 7 / 4.5 LF-IL PH delay time (ms) - optimistic 7.5 / 5.5

HF-OL PH delay time (ms) - optimistic 10.5 / 9LF-OL PH delay time (ms) - optimistic 14 / 12.5

Dynamic effects on inductance yes

Validation time for test facility: 2 msNote: not possible in the LHC tunnel

Three heaters have been deactivated in one coil

Page 8: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 8

Validation time for test facility: 2 msNote: not possible in the LHC tunnel

Page 9: Impact of Cu/NonCu on Quench Protection 1 Impact of Cu/NonCu on MQXF Quench Protection G. Ambrosio, V. Marinozzi, E. Todesco Conductor Video Mtg. April

Impact of Cu/NonCu on Quench Protection 9

LARP Magnets