56
Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 1 Imaging Colorimetry using a Digital Camera with Dental Applications Jan P. Allebach School of Electrical and Computer Engineering Purdue University 5 November 2002

Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

  • Upload
    vutu

  • View
    220

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 1

Imaging Colorimetry using a Digital Camera with Dental Applications

Jan P. Allebach School of Electrical and Computer Engineering

Purdue University 5 November 2002

Page 2: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 2

Applications of tooth colorimetry: assessment of efficacy of whitening agents

Before After

Image obtained from: http://www.westcentraldental.com/cosmetic.htm

Page 3: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 3

Applications of tooth colorimetry: matching color of restored tooth to neighbors

Page 4: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 4

Colorimetry research at Purdue •  Phase I

–  Development of theoretical framework for model-based colorimetry system and filter design

–  Simulation results only –  M. Wolski, C. A. Bouman, and J. P. Allebach, “Optimization of

Sensor Response Functions for Colorimetry of Reflective and Emissive Objects,” IEEE Trans. on Image Processing, Vol. 5, pp. 507-517, March 1996.

•  Phase II –  Application to colorimetry with a digital camera –  Characterization of digital camera –  Regression-based approach –  Experimental results with color patches and extracted teeth –  W. Wu, J. P. Allebach, M. Analoui, “Imaging Colorimetry Using a

Digital Camera,” Journal of Imaging Science and Technology, Special issue on color imaging, Vol. 44, pp. 267-279, July/August 2000.

Page 5: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 5

Colorimetry research at Purdue (cont.)

•  Phase III – Refinement of experimental system – Development of reflectance estimation based approach –  Experimental results with extracted and live teeth – D.Y. Ng, J. P. Allebach, Z. Pizlo, and M. Analoui, “Non-

Contact Colorimeter for Human Tooth Color Assessment using a Digital Camera,” Proceedings of the IS&T/SID 10th Color Imaging Conference, Scottsdale, AZ, 12 November – 15 November 2002.

Page 6: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 6

Collaborators/Sponsors

•  Mark Wolski,General Motors Research Laboratory •  Color Savvy Systems,Inc. •  Indiana University School of Dentistry

– Dr. Mostafa Analoui, (now withPfizer,Inc.) – Dr. George Stookey

•  Indiana 21st Century Fund

Page 7: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 7

Synopsis

•  What is color? •  Phase II

–  System architecture –  Filter design –  Preliminary results

•  Phase III –  System refinement –  “Clinical” system –  Experimental results

•  Future research (Phase IV?)

Page 8: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 8

What does color mean?

CameraPC/Workstation Printer

Copier

Scanner

Page 9: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 9

Each device has its own language

"I asked you to print sea green."

"You said to print RGB = (34, 229, 164)."

"That's sea green, isn't it?"

"No, it's yellow-green."

Page 10: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 10

Spectral Representation of Color

R(λ )

λ

λλ

I(λ ) S(λ )Illuminant Stimulus

Reflective Surface

Page 11: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 11

Trichromatic Representation of Color for Human Vision

•  3-D subspace RS = S(λ )QR∫ (λ )dλ

GS = S(λ )QG∫ (λ )dλ

BS = S(λ )QB∫ (λ )dλ

λ

QB(λ)

λ

QG(λ)

λ

QR(λ)

Page 12: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 12

Finite-Dimensional Approximation

Stimulus

λ

QB(λ)

λ

QG(λ)

λ

QR(λ)

λ

S(λ )

Sensor Response Functions

Page 13: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 13

Finite-Dimensional Approximation (cont.)

Q = qR qG qB[ ] =QR(λ1) QG (λ1) QB(λ1)

QR(λN ) QG (λN ) QB(λN )

⎢ ⎢

⎥ ⎥ ,

cS =RSGS

BS

⎢ ⎢

⎥ ⎥ , s =

S(λ1)

S(λN )

⎢ ⎢

⎥ ⎥

cS = QTs =qRT sqGT sqBT s

⎢ ⎢

⎥ ⎥

Page 14: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 14

Sensor Subspace •  Example 1: N = 2 wavelengths,

one monochromatic sensor

c = s1Tq = s2

Tq

stimuli s1and s2 are metamers to sensor q

Page 15: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 15

Role of Illuminant

illuminant modifies sensor response

S(λ ) = R(λ)I(λ)

RS = R(λ) I(λ)QR (λ)[ ]∫ dλ

GS = R(λ) I(λ )QG (λ)[ ]∫ dλ

BS = R(λ) I(λ)QB(λ)[ ]∫ dλ

Page 16: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 16

Effect of Illuminant Metamerism

•  Example 2: N = 2 wavlengths, two monochromatic sensors

stimuli s1and s2 are metamers to sensor q1 but not to q2

Page 17: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 17

Challenges of tooth color measurement

•  Smooth surface gives rise to specular reflection •  Irregular pattern of scattering of light gives

rise to non-uniform color on the surface •  Irregular size and shape complicate

measurements •  Fluorescence makes color less predictable

A device with high spatial resolution is needed

Page 18: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 18

What is a colorimetry system?

Measurement device Calibration mapping

⎥⎥⎥

⎢⎢⎢

100010001

Page 19: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 19

Prior work: colorimetry system design •  Calibration mapping

–  3 X 3 matrix (Wandell & Farrell, 1993, Finlayson & Drew, 1996)

–  3 X 6 matrix (Farrell et al, 1994) •  Measurement device

– Design a device (Wolski et al, 1996) –  Alter device sensitivity (Chen & Trussell, 1995) –  Increase the number of device channels (Tominaga

1999, Haneishi et al, 1995)

Page 20: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 20

Prior Work: colorimetry with a digital camera

•  Two main approaches have been adopted:  Physics-based approach:

 Model the electro-optics of the camera, [Daligault, 1991], [Quan et al, 2000], no experiments have been reported.

 Statistically-based approach:   Focus on what the camera ‘sees’ instead of how the

camera ‘sees’   Linear regression is widely used  Results have been reported for color patches such

as MacBeth Color Checkers ( [Lenz, 1996], [Balas, 1997]), Munsell Color Chips ( [Finlayson, 1997]) and IT8 target ( [Pointer, 2001])

Page 21: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 21

Phase II research

•  Digital camera + filters & calibration matrices •  Attack the problem simultaneously on both the design of

filters in measurement device and the mapping in color calibration

•  Obtain tristimulus values of a sample under pre-selected illumination conditions rather than recover its reflectance

Page 22: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 22

Multi-exposure colorimetry system

)1(

)1(

)1(

BGR

)(

)(

)(

f

f

f

N

N

N

BGR

illuminant L

reflectance r

Camera

Filter 1

Filter Nf

Camera

under illuminant L’

M ′ZYX

′′′

measurement device

Page 23: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 23

Multi-exposure colorimetry system

•  A calibration problem: if filters are given – Model-based or regression-based method

•  A system design problem: if filter design is desired – Model-based method only –  Interaction between measurement device and

calibration mapping

M ′ZYX

′′′

D

1f D

fNf

Page 24: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 24

System design: notation

fi : 31-pt. Filter transmittance of ith filter D: camera sensitivities A: CIE XYZ color matching function

ALRT ′=′

[ ] ][||][|][ 21 DfDfDfFfN

=

RLFS =

[ ] 21tN

ttrrrrR =

M ′ZYX

′′′

D

1f D

fNf

LrtL′

Page 25: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 25

Design goal and approach

•  Find the “best” F-M’ pair –  Small perceptual errors – Robust system –  Smooth filter transmittance

•  How? – RMS errors of linearized DE –  Perturbation of F – Cost on filter roughness

M ′ZYX

′′′

D

1f D

fNf

Page 26: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 26

System design: summary

}{max)( )( silluminant selectedpreiFh si

ti−=+= εε

fj Njf ,,2,11 of elements all0 …=≤≤

Minimize:

•  Optimal design through constrained optimization •  Restricted search among candidate solution set

Subject to:

M ′ZYX

′′′

D

1f D

fNf

LrtL′

Page 27: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 27

Calibration mappings

[ ][ ]

)(vec)()()()(vec

3

133

LABBILFILFBBILFMt

eqteq

teq

teq

tt

′′′⊗⋅⊗′′⊗=′ −

•  Model-based method

TSSSM tt ′=′ −1)(

•  Regression-based method

M ′ZYX

′′′

D

1f D

fNf

LrtL′

Page 28: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 28

Evaluation of system performance

·  DE in L* a* b* space

abTT )()( 21 ϕϕ − ∑ −=

iTiTi

N 221 ) of rowth () of rowth (1 ϕϕ

[ ] [ ]*** baLZYX ⎯→⎯ϕ

•  T1-T2: error in CIE XYZ space

•  Mean DE

Page 29: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 29

Perceptual error - 1

Page 30: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 30

Perceptual error - 2

Page 31: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 31

Robustness to filter variation

Page 32: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 32

Smoothness constraint and overall cost function

Page 33: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 33

Design a colorimetry system

•  Camera sensitivity •  Illumination conditions •  Training samples •  Number of exposures •  Robustness and smoothness (Kt,Ks) •  Filter design/restricted search

Page 34: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 34

400 450 500 550 600 650 700 0 0.02 0.04 0.06 0.08 0.1

0.12

wavelength (nm)

sens

itivi

ty

red green blue

Camera Sensitivity

300 400 500 600 700 800 0 0.5

1 1.5

2 2.5 x 10 5

wavelength (nm)

coun

ts

Monochromator Output

Camera sensitivity

•  Request data directly from manufacturer •  Estimate it through calibration

Page 35: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 35

Illumination conditions

•  Daylight from viewing booth & camera flash •  E, A, F, D65

400 450 500 550 600 650 700 0 5

10 15 20 25

Flash E A F D65

0.3 0.35 0.4 0.45 0.5 0.32 0.34 0.36 0.38 0.4

0.42 0.44

Flash E

A F

D65 x wavelength (nm)

pow

er

y

Chromaticity Diagram Illuminant Spectra

Page 36: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 36

1 2 3 4 5 6 10 -1

10 0

10 1

10 2

No. of bases

mea

n D E

Flash E A F D65

Training samples

•  Application dependent

–  120 DuPont paint chips –  170 natural objects –  1269 Munsell color chips

Page 37: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 37

Robustness and smoothness ab

MSRLFRLA ))(()( Δ+−ϕϕFlash-Flash

10 -8 10 -6 10 -4 10 -2 10 0 0 1 2 3 4 5 6 7

Kt

mea

n D E

Robustness issue: Ks = 1 No noise

10 -8 10 -6 10 -4 10 -2 10 0 10 0

10 1

10 2

Kt

mea

n D E

Robustness issue: Ks = 1 With noise

24

14

14

24

1

2

3

4

8

1010101010101010110110110110110

−−

−−

−st KK

10 -2 10 -1 10 0 10 1 10 2 0 1 2 3 4 5 6 7

Ks

mea

n D E

Smoothness issue: Kt = 1e-4

10 -2 10 -1 10 0 10 1 10 2 10 0

10 1

10 2

Ks

mea

n D E

Smoothness issue: Kt = 1e-4

MZYX

D

1f D

fNf

LrtL

Page 38: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 38

Design results

Optimal filter pairs for 2-exposure Flash-{Flash,E,A,F,D65} colorimetry systems when (Kt,Ks) = (10-4,1)

Optimal filters Optimal Wratten filters

400 450 500 550 600 650 700 0 0.2 0.4 0.6 0.8

1

wavelength (nm)

trans

mitt

ance

)(1of)(

2of

400 450 500 550 600 650 700 0 0.2 0.4 0.6 0.8

1

wavelength (nm)

trans

mitt

ance

)(1wf)(

2wf

Page 39: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 39

Design results

Optimal filters Optimal Wratten filters

(Channel sensitivities)

400 450 500 550 600 650 700 0

0.02

0.04

0.06

0.08

wavelength (nm)

sens

itivi

ty

)(1of

)(2of

400 450 500 550 600 650 700 0 0.02 0.04 0.06 0.08 0.1

wavelength (nm) se

nsiti

vity

)(1wf

)(2wf

Page 40: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 40

Simulation results

Cond. Flash E A F D65 Max.

Flash 0.2050 0.4571 0.5092 0.2720 0.4504 0.5092

E 0.1058 0.3600 0.2454 0.3452 0.2662 0.3600

A 0.4988 0.8363 0.1357 0.6614 0.7469 0.8363

F 0.3186 0.4321 0.2329 0.1980 0.4038 0.4321

D65 0.1429 0.4178 0.2466 0.3784 0.3218 0.4178

All 0.1132 0.3760 0.2433 0.3528 0.2811 0.3760

abMRLFALR ))(()( ′−′ ϕϕ

M ′ZYX

′′′

D

1f D

fNfLrt

L′

}{max)( )(s

iti

Fh εε +=

Page 41: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 41

Experimental results

Flash E A F Daylight

Model-based 4.4631 4.9830 4.7022 5.8554 4.5970

Regression-based 1.7792 1.8506 1.8504 1.9743 1.8291

abMST )()( ′−′ ϕϕ

Experimental results on 278 Munsell color chips using Wratten filter pair (WR11+WR38A,WR80B+WR85N6)

M ′ZYX

′′′

D

1f D

fNf

0 0.5 1 0 0.2 0.4 0.6 0.8

1

x

y

Chromaticity Diagram

LrtL′

Page 42: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 42

Phase II conclusion

•  Comparison

Regression-based Model-based

Accuracy Good Fair

Flexibility Poor Excellent

•  Filters used in regression-based method is the design from model-based technique

M ′ZYX

′′′

D

1f D

fNf

LrtL′

Page 43: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 43

Phase III research

•  Continuation of Wu’s work.

•  Modify the measurement setup to achieve higher accuracy. Improve prediction of the system

•  Make the prediction more robust to different illumination conditions.

•  Adapt the system for clinical use.

•  Adopt the statistical approach.

Page 44: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 44

  Illuminant-Dependent Colorimeter (IDC):   Slight modification of Wu’s Regression Model,

use an affine instead of homogeneous calibration matrix

  Only output CIE XYZ values   In this model, we calibrate, measure and match

the output under the same illuminant   Prediction is only meaningful under the same

lighting condition under which the calibration matrix was derived

  Illuminant-Independent Colorimeter (IIC):   Output spectral reflectance   In this model, we calibrate and measure under

the same illuminant but can match the output under any illuminant

Regression Models

Page 45: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 45

IIC and IDC for 2-exposure

system

Page 46: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 46

Experiment

•  Apparatus –  Kodak DCS460 Digital Camera –  Kodak wratten filters (WR11+WR85N6 and WR38A+WR80B) –  Photo Research PR705 spectroradiometer

•  Experiment 1 –  85 extracted teeth were measured under 3 different light

sources: »  MacBeth Daylight simulator »  2 AC-powered Vivitar 285 flash units »  PL900 DC regulated Halogen light with bifurcated fiber

optic light guide •  Experiment 2

–  21 human subjects were recruited. The top two incisors of each subjects were measured with Halogen Light

Page 47: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 47

Setup For Experiment 1

•  For Daylight simulator, the teeth were placed in the viewing booth. The incident angle of the light is approximately 45 degree

Page 48: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 48

Picture for Experiment 1 with flash units

Page 49: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 49

Picture for Experiment 2 with a subject

Page 50: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 50

Performance Evaluation

•  Experiment 1 – In each random selection, 70 of 85 extracted

teeth were randomly picked as training set, the remaining 15 comprised the test set.

•  Experiment 2 – In each random selection, 34 of 42 live human

teeth were randomly picked as training set, the remaining 8 comprised the test set.

•  In both experiments, 10,000 selections were performed.

•  The average of each selection was recorded. **abEΔΔE

Page 51: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 51

Results •  Experiment 1

–  IDC, measured with 3 different light sources:

–  IIC, measured with Halogen light

–  *percentage of random selections with average < 1.5

avgEΔMean StdDev Max % < 1.5*

D65 1.101 0.169 1.885 98.5Flash 0.965 0.198 1.775 99.4

Halogen 0.843 0.115 1.362 100

Illuminant

Mean StdDev Max % < 1.5*D65 (IIC) 0.833 0.109 1.354 100Flash (IIC) 0.841 0.110 1.364 100

Halogen (IIC) 0.843 0.115 1.366 100

Illuminant avgEΔ

**abEΔΔE

Page 52: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 52

•  Experiment 2: – Measurements for both IDC and IIC were taken under

the Halogen light. The spectral reflectance of each sample was reconstructed and evaluated under all the three light sources for IIC

–  *percentage of random selections with average < 1.5

avgEΔ

**abEΔ

Mean StdDev Max % < 1.5*D65 (IIC) 1.080 0.118 2.03 98.2Flash (IIC) 1.051 0.176 1.966 98.8

Halogen (IIC) 1.048 0.177 1.972 98.7Halogen (IDC) 1.049 0.177 1.980 98.7

Illuminant

ΔE

Page 53: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 53

•  Spectra for extracted teeth with IIC: The best among 15 reconstructions in a random selection. The values were computed for the Halogen light. **abEΔ

ΔE

Page 54: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 54

•  Spectra for extracted teeth with IIC: The worst among 15 reconstructions in the same random selection. The values were computed for the Halogen light. **abEΔ

ΔE

Page 55: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 55

Phase III conclusion

•  Both IIC and IDC work well with extracted and live teeth. •  The output of IIC can be matched under any illumination

condition whereas the output of IDC can only be matched under the illuminant for which the calibration matrix was designed.

•  However, a set of training samples which represents the tooth gamut adequately must be carefully picked to ensure good prediction.

Page 56: Imaging Colorimetry using a Digital Camera with Dental Applicationsece638/lectures/54. Spectral color... · Imaging Colorimetry using a Digital Camera with Dental Applications Procter

Imaging Colorimetry using a Digital Camera with Dental Applications Procter & Gamble - 5 November 2002 56

Future Work (Phase IV?)

•  Further clinical studies •  Highlight removal •  Fluorescence compensation