EAGLE 10,000 OPERATOR’S MANUAL For Machines with Code Number: 11096 IM830 November, 2005 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful. R • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • Copyright © 2005 Lincoln Global Inc. C US This manual covers equipment which is no longer in production by The Lincoln Electric Co. Specifications and availability of optional features may have changed.

IM830 EAGLE 10,000 - Lincoln Electric unless the maintenance work requires it to be running. _____ 1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes

  • Upload
    lammien

  • View
    216

  • Download
    2

Embed Size (px)

Citation preview

EAGLE™ 10,000

OPERATOR’S MANUAL

For Machines with Code Number: 11096

IM830November, 2005

Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However, youroverall safety can be increased byproper installation ... and thought-ful operation on your part. DONOT INSTALL, OPERATE ORREPAIR THIS EQUIPMENTWITHOUT READING THISMANUAL AND THE SAFETYPRECAUTIONS CONTAINEDTHROUGHOUT. And, mostimportantly, think before you actand be careful.

R

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

Copyright © 2005 Lincoln Global Inc.

C US

This manual covers equipment which is no longer in production by The Lincoln Electric Co. Speci�cations and availability of optional features may have changed.

FOR ENGINEpowered equipment.

1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

____________________________________________________1.b. Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes outdoors.

____________________________________________________1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.Stop the engine and allow it to cool beforerefueling to prevent spilled fuel from vaporiz-ing on contact with hot engine parts andigniting. Do not spill fuel when filling tank. Iffuel is spilled, wipe it up and do not startengine until fumes have been eliminated.

____________________________________________________1.d. Keep all equipment safety guards, covers and devices in

position and in good repair.Keep hands, hair, clothing andtools away from V-belts, gears, fans and all other movingparts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safetyguards to perform required maintenance. Removeguards only when necessary and replace them when themaintenance requiring their removal is complete.Always use the greatest care when working near movingparts.

___________________________________________________1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor oridler by pushing on the throttle control rodswhile the engine is running.

___________________________________________________1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenancework, disconnect the spark plug wires, distributor cap ormagneto wire as appropriate.

iSAFETYi

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that youpurchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is availablefrom the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES AREPERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ‘95

ELECTRIC AND MAGNETIC FIELDSmay be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physicianbefore welding.

2.c. Exposure to EMF fields in welding may have other healtheffects which are now not known.

2.d. All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Securethem with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode andwork cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close aspossible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove theradiator pressure cap when the engine ishot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituentsare known to the State of California to cause can-cer, birth defects, and other reproductive harm.

The engine exhaust from this product containschemicals known to the State of California to causecancer, birth defects, or other reproductive harm.

The Above For Diesel Engines The Above For Gasoline Engines

iiSAFETYii

ARC RAYS can burn.4.a. Use a shield with the proper filter and cover

plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistantmaterial to protect your skin and that of your helpers fromthe arc rays.

4.c. Protect other nearby personnel with suitable, non-flammablescreening and/or warn them not to watch the arc nor exposethemselves to the arc rays or to hot spatter or metal.

ELECTRIC SHOCK cankill.3.a. The electrode and work (or ground) circuits

are electrically “hot” when the welder is on.Do not touch these “hot” parts with your bareskin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation.Make certain the insulation is large enough to cover your fullarea of physical contact with work and ground.

In addition to the normal safety precautions, if weldingmust be performed under electrically hazardousconditions (in damp locations or while wearing wetclothing; on metal structures such as floors, gratings orscaffolds; when in cramped positions such as sitting,kneeling or lying, if there is a high risk of unavoidable oraccidental contact with the workpiece or ground) usethe following equipment:

• Semiautomatic DC Constant Voltage (Wire) Welder.• DC Manual (Stick) Welder.• AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode,electrode reel, welding head, nozzle or semiautomaticwelding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electricalconnection with the metal being welded. The connectionshould be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical(earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable andwelding machine in good, safe operating condition. Replacedamaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts ofelectrode holders connected to two welders because voltagebetween the two can be the total of the open circuit voltageof both welders.

3.i. When working above floor level, use a safety belt to protectyourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

FUMES AND GASEScan be dangerous.5.a. Welding may produce fumes and gases

hazardous to health. Avoid breathing thesefumes and gases.When welding, keepyour head out of the fume. Use enoughventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. Whenwelding with electrodes which require specialventilation such as stainless or hard facing (seeinstructions on container or MSDS) or on lead orcadmium plated steel and other metals or coatingswhich produce highly toxic fumes, keep exposure aslow as possible and below Threshold Limit Values (TLV)using local exhaust or mechanical ventilation. Inconfined spaces or in some circumstances, outdoors, arespirator may be required. Additional precautions arealso required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vaporscoming from degreasing, cleaning or spraying operations.The heat and rays of the arc can react with solvent vapors toform phosgene, a highly toxic gas, and other irritating prod-ucts.

5.c. Shielding gases used for arc welding can displace air andcause injury or death. Always use enough ventilation,especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for thisequipment and the consumables to be used, including thematerial safety data sheet (MSDS) and follow youremployer’s safety practices. MSDS forms are available fromyour welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ‘95

FOR ELECTRICALLYpowered equipment.

8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.

8.b. Install equipment in accordance with the U.S. NationalElectrical Code, all local codes and the manufacturer’srecommendations.

8.c. Ground the equipment in accordance with the U.S. NationalElectrical Code and the manufacturer’s recommendations.

CYLINDER may explodeif damaged.7.a. Use only compressed gas cylinders

containing the correct shielding gas for theprocess used and properly operatingregulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable forthe application and maintained in good condition.

7.b. Always keep cylinders in an upright position securelychained to an undercarriage or fixed support.

7.c. Cylinders should be located:• Away from areas where they may be struck or subjected tophysical damage.

• A safe distance from arc welding or cutting operations andany other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any otherelectrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outletwhen opening the cylinder valve.

7.f. Valve protection caps should always be in place and handtight except when the cylinder is in use or connected foruse.

7.g. Read and follow the instructions on compressed gascylinders, associated equipment, and CGA publication P-l,“Precautions for Safe Handling of Compressed Gases inCylinders,” available from the Compressed Gas Association1235 Jefferson Davis Highway, Arlington, VA 22202.

iiiSAFETYiii

Mar ‘95

WELDING SPARKS cancause fire or explosion.6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to preventthe welding sparks from starting a fire.Remember that welding sparks and hot

materials from welding can easily go through small cracksand openings to adjacent areas. Avoid welding nearhydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,special precautions should be used to prevent hazardoussituations. Refer to “Safety in Welding and Cutting” (ANSIStandard Z49.1) and the operating information for theequipment being used.

6.c. When not welding, make certain no part of the electrodecircuit is touching the work or ground. Accidental contactcan cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until theproper steps have been taken to insure that such procedureswill not cause flammable or toxic vapors from substancesinside. They can cause an explosion even though they havebeen “cleaned”. For information, purchase “RecommendedSafe Practices for the Preparation for Welding and Cutting ofContainers and Piping That Have Held HazardousSubstances”, AWS F4.1 from the American Welding Society(see address above).

6.e. Vent hollow castings or containers before heating, cutting orwelding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oilfree protective garments such as leather gloves, heavy shirt,cuffless trousers, high shoes and a cap over your hair. Wearear plugs when welding out of position or in confined places.Always wear safety glasses with side shields when in awelding area.

6.g. Connect the work cable to the work as close to the weldingarea as practical. Work cables connected to the buildingframework or other locations away from the welding areaincrease the possibility of the welding current passingthrough lifting chains, crane cables or other alternate cir-cuits. This can create fire hazards or overheat lifting chainsor cables until they fail.

6.h. Also see item 1.c.

Mar. ‘93

ivSAFETYiv

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissent dans cemanuel aussi bien que les précautions de sûreté générales suiv-antes:

Sûreté Pour Soudage A L’Arc1. Protegez-vous contre la secousse électrique:

a. Les circuits à l’électrode et à la piéce sont sous tensionquand la machine à souder est en marche. Eviter toujourstout contact entre les parties sous tension et la peau nueou les vétements mouillés. Porter des gants secs et sanstrous pour isoler les mains.

b. Faire trés attention de bien s’isoler de la masse quand onsoude dans des endroits humides, ou sur un planchermetallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grandepartie du corps peut être en contact avec la masse.

c. Maintenir le porte-électrode, la pince de masse, le câblede soudage et la machine à souder en bon et sûr étatdefonctionnement.

d.Ne jamais plonger le porte-électrode dans l’eau pour lerefroidir.

e. Ne jamais toucher simultanément les parties sous tensiondes porte-électrodes connectés à deux machines à souderparce que la tension entre les deux pinces peut être letotal de la tension à vide des deux machines.

f. Si on utilise la machine à souder comme une source decourant pour soudage semi-automatique, ces precautionspour le porte-électrode s’applicuent aussi au pistolet desoudage.

2. Dans le cas de travail au dessus du niveau du sol, se protégercontre les chutes dans le cas ou on recoit un choc. Ne jamaisenrouler le câble-électrode autour de n’importe quelle partiedu corps.

3. Un coup d’arc peut être plus sévère qu’un coup de soliel,donc:

a. Utiliser un bon masque avec un verre filtrant appropriéainsi qu’un verre blanc afin de se protéger les yeux du ray-onnement de l’arc et des projections quand on soude ouquand on regarde l’arc.

b. Porter des vêtements convenables afin de protéger lapeau de soudeur et des aides contre le rayonnement del‘arc.

c. Protéger l’autre personnel travaillant à proximité ausoudage à l’aide d’écrans appropriés et non-inflammables.

4. Des gouttes de laitier en fusion sont émises de l’arc desoudage. Se protéger avec des vêtements de protection libresde l’huile, tels que les gants en cuir, chemise épaisse, pan-talons sans revers, et chaussures montantes.

5. Toujours porter des lunettes de sécurité dans la zone desoudage. Utiliser des lunettes avec écrans lateraux dans leszones où l’on pique le laitier.

6. Eloigner les matériaux inflammables ou les recouvrir afin deprévenir tout risque d’incendie dû aux étincelles.

7. Quand on ne soude pas, poser la pince à une endroit isolé dela masse. Un court-circuit accidental peut provoquer unéchauffement et un risque d’incendie.

8. S’assurer que la masse est connectée le plus prés possiblede la zone de travail qu’il est pratique de le faire. Si on placela masse sur la charpente de la construction ou d’autresendroits éloignés de la zone de travail, on augmente le risquede voir passer le courant de soudage par les chaines de lev-age, câbles de grue, ou autres circuits. Cela peut provoquerdes risques d’incendie ou d’echauffement des chaines et descâbles jusqu’à ce qu’ils se rompent.

9. Assurer une ventilation suffisante dans la zone de soudage.Ceci est particuliérement important pour le soudage de tôlesgalvanisées plombées, ou cadmiées ou tout autre métal quiproduit des fumeés toxiques.

10. Ne pas souder en présence de vapeurs de chlore provenantd’opérations de dégraissage, nettoyage ou pistolage. Lachaleur ou les rayons de l’arc peuvent réagir avec les vapeursdu solvant pour produire du phosgéne (gas fortement toxique)ou autres produits irritants.

11. Pour obtenir de plus amples renseignements sur la sûreté,voir le code “Code for safety in welding and cutting” CSAStandard W 117.2-1974.

PRÉCAUTIONS DE SÛRETÉ POURLES MACHINES À SOUDER ÀTRANSFORMATEUR ET ÀREDRESSEUR

1. Relier à la terre le chassis du poste conformement au code del’électricité et aux recommendations du fabricant. Le dispositifde montage ou la piece à souder doit être branché à unebonne mise à la terre.

2. Autant que possible, I’installation et l’entretien du poste seronteffectués par un électricien qualifié.

3. Avant de faires des travaux à l’interieur de poste, la debranch-er à l’interrupteur à la boite de fusibles.

4. Garder tous les couvercles et dispositifs de sûreté à leurplace.

Thank You for selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much pride as we have in bringing this product to you!

Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep ithandy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.The level of seriousness to be applied to each is explained below:

WARNINGThis statement appears where the information must be followed exactly to avoid serious personal injury orloss of life.

This statement appears where the information must be followed to avoid minor personal injury or damage tothis equipment.

CAUTION

Please Examine Carton and Equipment For Damage ImmediatelyWhen this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claimsfor material damaged in shipment must be made by the purchaser against the transportation company at thetime the shipment is received.

Please record your equipment identification information below for future reference. This information can befound on your machine nameplate.

Model Name & Number _____________________________________

Code & Serial Number _____________________________________

Date of Purchase _____________________________________

Whenever you request replacement parts for or information on this equipment always supply the informationyou have recorded above.

vv

viTABLE OF CONTENTSPage

Installation.......................................................................................................................Section ATechnical Specifications.......................................................................................................A-1

Safety Precautions ........................................................................................................A-2Machine Grounding.......................................................................................................A-2Spark Arrester ...............................................................................................................A-2Towing...........................................................................................................................A-2

Pre-Operation Engine Service..............................................................................................A-3Fuel ...............................................................................................................................A-3Oil ..................................................................................................................................A-3Battery Connections......................................................................................................A-3Welding Cable Connections..........................................................................................A-3 Angle of Operation ........................................................................................................A-4Lifting.............................................................................................................................A-4High Altitude Operation .................................................................................................A-4Location and Ventilation................................................................................................A-4Stacking ........................................................................................................................A-4Connection of Wire Feeders .........................................................................................A-4Connection of TIG Module ............................................................................................A-5Additional Safety Precautions,Welding Operation Output.............................................A-5

Auxiliary Power Receptacles, and Plugs ......................................................................A-5,A-6Motor Starting and Extension Cord Length Table ................................................................A-6Electrical Device Used with the Ranger 10,000 ...................................................................A-7Auxiliary Power While Welding, Standby Power Connections ............................................A-8Premises Wiring ...................................................................................................................A-9

________________________________________________________________________________Operation.........................................................................................................................Section B

Safety Precautions ...............................................................................................................B-1General Description..............................................................................................................B-1Welder Controls Function and Operation .............................................................................B-1Range and Control Switch....................................................................................................B-2

Start in/Shutdown Instructions.....................................................................................................B-3Starting the Engine........................................................................................................B-3Safety Precautions ........................................................................................................B-3Stopping the Engine......................................................................................................B-3Break-In Period .............................................................................................................B-3

Welding Process ..................................................................................................................B-4Stick (Constant Current) Welding..................................................................................B-4TIG (Constant Current) Welding ...................................................................................B-4Wire Feed Welding Processes .....................................................................................B-4Arc Gouging ..................................................................................................................B-4Summary of Welding Processes and Current Ranges for Tungsten Electrodes ..........B-5

________________________________________________________________________________Accessories ........................................................................................................Section C

Optional Equipment ...............................................................................................C-1Recommended Equipment ....................................................................................C-1

________________________________________________________________________Maintenance ....................................................................................................Section D

Safety Precautions ................................................................................................D-1Routine Engine Maintenance ..........................................................................D-1,D2Engine Adjustments...............................................................................................D-3Slip Rings ..............................................................................................................D-3

Battery Maintenance .......................................................................................D-3Engine Maintenance Parts..............................................................................D-3

________________________________________________________________________Troubleshooting ..............................................................................................Section E

How to Use Troubleshooting Guide.......................................................................E-1Troubleshooting Guide...................................................................................E-2, E-3

________________________________________________________________________Wiring Diagrams & Dimension Print..............................................................Section F

Wiring and Connection Diagrams....................................................................F-1,F-2Dimension Print......................................................................................................F-3

________________________________________________________________________Parts List ..................................................................................................................P488

________________________________________________________________________

vi

A-1INSTALLATION

EAGLE 10,000

A-1

TECHNICAL SPECIFICATIONS - EAGLE 10,000 (K2343-1 )

INPUT - GASOLINE ENGINE

RATED OUTPUT @ 104°F (40°C) - WELDER

HEIGHT WIDTH DEPTH WEIGHT

30.3 in. 19.1 in. 42.0 in.770 mm 485 mm 1067 mm 502 lbs. (228kg)

RATED OUTPUT @ 104°F (40°C) - GENERATOR

Welding Output

DC Constant Current 210A / 25V / 100%

Auxiliary Power 1

10,000 Watts Peak, 60 Hz AC9,000 Watts Continuous, 60 Hz AC

120/240 Volts

PHYSICAL DIMENSIONS

Make/Model

(K2343-1)KohlerCH20S

Description

2 cylinder4 Cycle

Air-CooledGasolineEngine.

Aluminum Alloywith Cast Iron

Liners,Electronic Start

OperatingSpeed (RPM)

High Idle 3700

Full Load 3500

Low Idle 2200

Displacementcu. in.

(cu.cm.)

38(624)Kohler

Capacities

Fuel:9 Gal (34 L)

Lubricating Oil:2.0 Qts. (1.9 L)

Horsepower

20 HP @3600 RPM

(Kohler)

StartingSystem

12VDCBattery

Electric StartGroup 58Battery(435 coldCrankingAmps)

1. Output rating in watts is equivalent to volt - amperes at unity factor.Output voltage is within +/-10% at all loads up to rated capacity.When welding available auxiliary power will be reduced.

A-2INSTALLATION

EAGLE 10,000

A-2

SAFETY PRECAUTIONS

MACHINE GROUNDING

Because this portable engine driven welder or genera-tor creates it’s own power, it is not necessary to con-nect it’s frame to an earth ground, unless the machineis connected to premises wiring (your home, shop,etc.).

To prevent dangerous electric shock, other equip-ment to which this engine driven welder suppliespower must:

• be grounded to the frame of the welder using a grounded type plug, or be double insulated.

Do not ground the machine to a pipe that carriesexplosive or combustible material.------------------------------------------------------------------------

When this welder is mounted on a truck or trailer, it’sframe must be electrically bonded to the metal frameof the vehicle. Use a #8 or larger copper wire connect-ed between the machine grounding stud and theframe of the vehicle.

Where this engine driven welder is connected topremises wiring such as that in your home or shop, it’sframe must be connected to the system earth ground.See further connection instructions in the section enti-tled “Standby Power Connections”, as well as the arti-cle on grounding in the latest National Electrical Codeand the local code.

In general, if the machine is to be grounded, it shouldbe connected with a #8 or larger copper wire to a solidearth ground such as a metal water pipe going intothe ground for at least ten feet and having no insulat-ed joints, or to the metal framework of a buildingwhich has been effectively grounded. The NationalElectrical Code lists a number of alternate means ofgrounding electrical equipment. A machine groundingstud marked with the symbol is provided on thefront of the welder.

SPARK ARRESTER

Some federal, state, or local laws may require thatgasoline engines be equipped with exhaust sparkarresters when they are operated in certain locationswhere unarrested sparks may present a fire hazard.The standard muffler included with this welder doesnot qualify as a spark arrester. When required by localregulations, the K894-1 spark arrester must beinstalled and properly maintained.

An incorrect arrester may lead to damage to theengine or adversely affect performance.------------------------------------------------------------------------TOWINGThe recommended trailer for use with this equipmentfor road, in-plant and yard towing by a vehicle(1) isLincoln’s K957-1. If the user adapts a non-Lincolntrailer, he must assume responsibility that the methodof attachment and usage does not result in a safetyhazard nor damage the welding equipment. Some ofthe factors to be considered are as follows:

1. Design capacity of trailer vs. weight of Lincolnequipment and likely additional attachments.

2. Proper support of, and attachment to, the base ofthe welding equipment so there will be no unduestress to the framework.

CAUTION

Do not attempt to use this equipment until youhave thoroughly read the engine manufacturer’smanual supplied with your welder. It includesimportant safety precautions, detailed enginestarting, operating and maintenance instructions,and parts lists.------------------------------------------------------------------------

ELECTRIC SHOCK can kill.• Do not touch electrically live parts orelectrode with skin or wet clothing.• Insulate yourself from work andground• Always wear dry insulating gloves.

------------------------------------------------------------------------ENGINE EXHAUST can kill.• Use in open, well ventilated areas orvent exhaust outside.

------------------------------------------------------------------------MOVING PARTS can injure.• Do not operate with doors open orguards off.• Stop engine before servicing.• Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information atfront of this operator’s manual.

-----------------------------------------------------------

WARNING

WARNING

3. Proper placement of the equipment on the trailer toinsure stability side to side and front to back whenbeing moved and when standing by itself whilebeing operated or serviced.

4. Typical conditions of use, i.e., travel speed; rough-ness of surface on which the trailer will be operated;environmental conditions.

5. Conformance with federal, state and local laws(1)

(1) Consult applicable federal, state and local laws regarding specific

requirements for use on public highways.

READ the engine operating and maintenanceinstructions supplied with this machine.

FUEL

Fil the fuel tank with clean, fresh, lead-free gasoline. Observe fuelgauge while filling to prevent overfilling.

A-3INSTALLATION

EAGLE 10,000

A-3

BATTERY CONNECTIONSUse caution as the electrolyte is a strong acid that canburn skin and damage eyes.

------------------------------------------------------------------------------------------This welder is shipped with the negative battery cable disconnected.Make sure that the Engine Switch is in the “OFF” position andattach the disconnected cable securely to the negative battery ter-minal before attempting to operate the machine. If the battery is dis-charged and does not have enough power to start the engine, seethe battery charging instructions in the Battery section.

NOTE: This machine is furnished with a wet charged battery; ifunused for several months, the battery may require a boostercharge. Be careful to charge the battery with the correct polarity.

WELDING OUTPUT CABLES

With the engine off, connect the electrode and work cables to thestuds provided. These connections should be checked periodicallyand tightened if necessary. Loose connections will result in over-heating of the output studs.

When welding at a considerable distance from the welder, be sureyou use ample size welding cables. Listed below are copper cablesizes recommended for the rated current and duty cycle. Lengthsstipulated are the distance from the welder to work and back to thewelder again. Cable sizes are increased for greater lengths primari-ly for the purpose of minimizing cable voltage drop.

TOTAL COMBINED LENGTH OFELECTRODE AND WORK CABLES

0-100 Ft.(0-328 m)

100-200 Ft.(328-656 m)200-250 Ft.(656-820 m)

225 Amps100% Duty Cycle

1 AWG

1 AWG

1/0 AWG

• Damage to the fuel tank may causefire or explosion. Do not drill holesin the EAGLE 10,000 base or weld tothe EAGLE 10,000 base.

WARNING

CAUTION

OIL

The EAGLE 10,000 is shipped with the enginecrankcase filled with SAE 10W-30 oil. Check the oillevel before starting the engine. If it is not up to the fullmark on the dip stick, add oil as required. Make certainthat the oil filler cap is tightened securely. Refer to theengine Owner’s Manual for specific oil recommenda-tions.

LUBRICATION SYSTEM CAPACITY(INCLUDING FILTER)

Kohler CH20S - 2.0 Quarts (1.9 Liters)

VEHICLE MOUNTING

Improperly mounted concentrated loads may cause unstablevehicle handling and tires or other components to fail.• Only transport this Equipment on serviceable vehicles which

are rated and designed for such loads.• Distribute, balance and secure loads so vehicle is stable

under conditions of use.• Do not exceed maximum rated loads for components such as

suspension, axles and tires.• Mount equipment base to metal bed or frame of vehicle.• Follow vehicle manufacturer’s instructions.------------------------------------------------------------------------------------------

WARNING

• Stop engine while fueling.• Do not smoke when fueling.• Keep sparks and flame away from

tank.• Do not leave unattended while fuel-

ing.• Wipe up spilled fuel and allow fumes

to clear before starting engine.• Do not overfill tank, fuel expansion

may cause overflow.GASOLINE FUEL ONLY

---------------------------------------------------------------------------------

WARNING

GASOLINEcan cause fireor explosion.

A-4INSTALLATION

EAGLE 10,000

A-4

ANGLE OF OPERATIONInternal combustion engines are designed to run in alevel condition which is where the optimum perfor-mance is achieved. The maximum angle of operationfor the engine is 15 degrees from horizontal in anydirection. If the engine is to be operated at an angle,provisions must be made for checking and maintain-ing the oil at the normal (FULL) oil capacity in thecrankcase in a level condition.

When operating at an angle, the effective fuel capaci-ty will be slightly less than the specified 9 gal (34 L).

LIFTINGThe EAGLE 10,000 weighs approximately 575 lbs.(281kg) with a full tank of gasoline. A lift bail ismounted to the machine and should always be usedwhen lifting the machine.

ADDITIONAL SAFETY PRECAUTIONS

• Lift only with equipment of adequatelifting capacity.

• Be sure machine is stable when lift-ing.

• Do not lift this machine using lift bailif it is equipped with a heavy acces-sory such as trailer or gas cylinder.

FALLING • Do not lift machine if lift bail is

EQUIPMENT can damaged.

cause injury. • Do not operate machine while

suspended from lift bail.

-----------------------------------------------------------------------HIGH ALTITUDE OPERATIONIf the EAGLE 10,000 will be consistently operated ataltitudes above 5000 ft, a carburetor jet designed forhigh altitudes should be installed. This will result inbetter fuel economy, cleaner exhaust, and longerspark plug life. It will not give increased power whichis decreased at higher altitudes. Engine horsepoweris reduced by 3.5% per 1000ft.(3280m) for altitudesabove 377 ft.(1237m).

Do not operate a EAGLE 10,000 with a high alti-tude jet installed at altitudes below5000ft.(16,404m). This will result in the enginerunning too lean and result in higher engine oper-ating temperatures which can shorten engine life.-----------------------------------------------------------------------Contact your local Kohler Authorized Dealer for highaltitude jet kits that are available from the enginemanufacturer.

Muffler Relocation • Shut off welder and allow muffler to cool before

touching muffler.------------------------------------------------------------------------The EAGLE 10,000 is shipped with the exhaust com-ing out on the left side. The exhaust can be changedto the opposite side by removing the two screws thathold the exhaust port cover in place and installing thecover on the opposite side. (Operating the EAGLE10,000 without the cover in place will result in a highernoise level and no increase in machine output.)

LOCATION / VENTILATIONThe welder should be located to provide an unrestrict-ed flow of clean, cool air to the cooling air inlets and toavoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder sothat engine exhaust fumes are properly vented to anoutside area.

STACKINGEAGLE 10,000 machines cannot be stacked.

CONNECTION OF LINCOLN ELECTRICWIRE FEEDERS

Note: A constant voltage (CV) power source is rec-ommended for wire feeder applications. TheLN-15 and LN-25 may be used with a constantcurrent (CC) power source, such as the EAGLE10,000, for non-critical applications where weldquality and deposition properties are not critical.

Shut off welder before making any electricalconnections.------------------------------------------------------------------------WIRE FEED CONNECTION OF LN-15 ACROSS-THE-ARC WIRE FEEDERThe LN-15 has an internal contactor and the electrodeis not energized until the gun trigger is closed. Whenthe gun trigger is closed the wire will begin to feedand the welding process is started.

a. Shut the welder off.

b. For electrode Positive, connect the electrodecable to the "+" terminal of the welder and workcable to the "-" terminal of the welder. For elec-trode Negative, connect the electrode cable "-"terminal of the welder and work cable to the "+"terminal of the welder.

CAUTION

WARNING

WARNING

WARNING

A-5INSTALLATION

EAGLE 10,000

A-5

INSTRUCTIONSADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the roof and casesides in place as this provides maximum protectionfrom moving parts and assures proper cooling air flow.

Read and understand all Safety Precautions beforeoperating this machine. Always follow these and anyother safety procedures included in this manual and inthe Engine Owner’s Manual.

WELDER OPERATION

WELDER OUTPUT• Maximum Open Circuit Voltage at 3700 RPM is

80 Volts RMS.• Duty Cycle is the percentage of time the load is

being applied in a 10 minute period. For example, a60% duty cycle represents 6 minutes of load and 4minutes of no load in a 10 minute period. Duty Cyclefor the EAGLE 10,000 is 100%.

AUXILIARY POWER

The EAGLE 10,000 can provide, up to 10,000 watts of120/240 volts AC, single phase 60Hz power peak useand up to 9,000 watts of 120/240 volts AC, singlephase 60Hz power for continuous use. The front ofthe machine includes three receptacles for connectingthe AC power plugs; one 50 amp 120/240 volt NEMA14-50R receptacle and two 20 amp 120 volt NEMA 5-20R receptacles. Output voltage is within +/-10% at allloads up to rated capacity.

Do not connect any plugs that connect to thepower receptacles in parallel.------------------------------------------------------------------------

Start the engine and set the “IDLER” control switch tothe desired operating mode. Set the “CONTROL” to10. Voltage is now correct at the receptacles for auxil-iary power.

c. Attach the single lead from the front of the LN-15to work using the spring clip at the end of the lead.This is a control lead to supply current to the wirefeeder motor; it does not carry welding current.

d. Set the “RANGE” switch to a suitable position.e. Place the Engine switch in the “Auto Idle” position.f. Set the Welding Mode on the LN-15 to the “CC” mode.g. Adjust the wire feed speed at the LN-15 and adjust

the welding current with the output “CONTROL” atthe welder. Output “CONTROL” must be set above 3.

Note: LN-15 Control Cable model will not work withthe EAGLE 10,000.

CONNECTION OF THE LN-25 TO THEEAGLE 10,000

a. Shut the welder off.b. For electrode Positive, connect the electrode

cable from the LN-25 to the "+" terminal of thewelder and work cable to the "-" terminal of thewelder. For electrode Negative, connect the elec-trode cable from the LN-25 to the "-" terminal ofthe welder and work cable to the "+" terminal ofthe welder.

c. Position the “RANGE” switch to a suitable posi-tion.

d. Attach the single lead from the LN-25 control boxto the work using the spring clip on the end of thelead - it carries no welding current.

e. Place the engine switch in the “AUTO IDLE” posi-tion.

f. Set the Wire Feed Mode switch on the LN-25 tothe “CC” mode.

g. Adjust wire feed speed at the LN-25 and adjustthe welding current with the output “CONTROL”at the welder.

Note: The welding electrode is energized at alltimes, unless an LN-25 with built-in contactoris used. If the output “CONTROL” is setbelow “3”, the LN-25 contactor may not pullin.

CONNECTION OF K930-2 TIG MODULE TO THEEAGLE 10,000.

The TIG Module is an accessory that provides highfrequency and shielding gas control for AC and DCGTAW (TIG) welding. The Eagle 10,000 cannot weldin AC, but the K930-1 will allow for high frequencestarting and with the K938-1 contactor option, a coldTIG Torch. See IM528 supplied with the TIG Modulefor installation instructions.

Note: The TIG Module does not require the use of ahigh frequency bypass capacitor. However, ifthe EAGLE 10,000 is used with any other highfrequency equipment, the bypass capacitormust be installed, order kit T12246.

EAGLE 10,000

Constant Current 210 Amps DC @ 25 Volts

CAUTION

A-6INSTALLATION

EAGLE 10,000

A-6

120 V DUPLEX RECEPTACLES

The 120V auxiliary power receptacles should only beused with three wire grounded type plugs or approveddouble insulated tools with two wire plugs.

The current rating of any plug used with the systemmust be at least equal to the current load through theassociated receptacle.

MOTOR STARTING

Most 1.5 hp AC single phase motors can be started ifthere is no load on the motor or other load connectedto the machine, since the full load current rating of a1.5 hp motor is approximately 20 amperes (10amperes for 240 volt motors). The motor may be runat full load when plugged into only one side of theduplex receptacle. Larger motors through 2 hp can berun provided the receptacle rating as previously statedis not exceeded. This may necessitate 240V operationonly.

GND

120 V

120 V*

240 V

*Current Sensing for Automatic Idle.(Receptacle viewed from front of Machine)

EAGLE 10,000 Extension Cord Length Recommendations(Use the shortest length extension cord possible sized per the following table.)

Current(Amps)

1520152038

VoltageVolts120120240240240

Load(Watts)18002400360048009000

30

60

(9)

(18)

40307560

(12)(9)

(23)(18)

7550

15010050

(23)(15)(46)(30)(15)

12588

22517590

(38)(27)(69)(53)(27)

175138350275150

(53)(42)

(107)(84)(46)

300225600450225

(91)(69)

(183)(137)(69)

Maximum Allowable Cord Length in ft. (m) for Conductor Size

Conductor size is based on maximum 2.0% voltage drop.

14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG

120/240 VOLT DUAL VOLTAGE RECEPTACLE

The 120/240 volt receptacle can supply up to 38 ampsof 240 volt power to a two wire circuit, up to 38 ampsof 120 volts power from each side of a three wire cir-cuit (up to 76 amps total). Do not connect the 120 voltcircuits in parallel. Current sensing for the automaticidle feature is only in one leg of the three wire circuitas shown in the following column.

A-7INSTALLATION

EAGLE 10,000

A-7

TABLE lllELECTRICAL DEVICE USE WITH THE EAGLE 10,000.

Type Common Electrical Devices Possible Concerns

Resistive Heaters, toasters, incandescent NONElight bulbs, electric range, hot pan, skillet, coffee maker.

Capacitive TV sets, radios, microwaves, Voltage spikes or high voltageappliances with electrical control. regulation can cause the capac-

itative elements to fail. Surgeprotection, transient protection,and additional loading is recom-mended for 100% fail-safeoperation. DO NOT RUNTHESE DEVICES WITHOUTADDITIONAL RESISTIVE TYPELOADS.

Inductive Single-phase induction motors, These devices require largedrills, well pumps, grinders, small current inrush for starting. refrigerators, weed and hedge Some synchronous motors may trimmers be frequency sensitive to attain

maximum output torque, butthey SHOULD BE SAFE fromany frequency induced failures.

Capacitive/Inductive Computers, high resolution TV sets, An inductive type line condition-complicated electrical equipment. er along with transient and

surge protection is required,and liabilities still exist. DONOT USE THESE DEVICESWITH A EAGLE 10,000

The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect-ed to the EAGLE 10,000.

A-8INSTALLATION

EAGLE 10,000

A-8

STANDBY POWER CONNECTIONS

The EAGLE 10,000 is suitable for temporary, standby,or emergency power using the engine manufacturer’srecommended maintenance schedule.

The EAGLE 10,000 can be permanently installed as astandby power unit for 240V-3 wire, single phase 38ampere service.

(Connections must be made by a licensed electri-cian who can determine how the 120/240V powercan be adapted to the particular installation andcomply with all applicable electrical codes.) Thefollowing information can be used as a guide bythe electrician for most applications (refer also tothe connection diagram shown in Figure 1.)-------------------------------------------------------------------------

1. Install a double pole, double throw switch betweenthe power company meter and the premisesdisconnect.

Switch rating must be the same or greater thanthe customer’s premises disconnect and serviceovercurrent protection.

2. Take necessary steps to assure load is limited tothe capacity of the EAGLE 10,000 by installing a 38 amp 240V double pole circuit breaker.Maximum rated load for the 240V auxiliary is 38amperes. Loading above 38 amperes will reduceoutput voltage below the allowable -10% of ratedvoltage which may damage appliances or othermotor-driven equipment.

3. Install a 50 amp 120/240V plug (NEMA type 14-50)to the Double Pole Circuit Breaker using No. 8, 4 conductor cable of the desired length. (The50 amp 120/240V plug is available in theoptional plug kit.)

4. Plug this cable into the 50 amp 120/240Vreceptacle on the EAGLE 10,000 case front.

WARNING

AUXILIARY POWER WHILE WELDING

Simultaneous welding and power loads are permittedby following Table I. The permissible currents shownassume that current is being drawn from either the120V or 240V supply (not both at the same time).Also, the “Output Control” is set at “10” for maximumauxiliary power.

TABLE ISIMULTANEOUS WELDING AND POWER

Output Selector Permissible Power Permissible AuxiliarySetting Watts (Unity Power Current in Amperes

Factor) @ 120V *-or- @ 240V

Max. Stick or WireFeed Setting None 0 0

145 Stick Setting 3950 32 16

90 Stick Setting 6000 50** 25

NO WELDING 9000 76** 38

* Each duplex receptacle is limited to 20 amps.

**Not to exceed 40A per 120VAC branch circuit when

splitting the 240 VAC output.

240 Volt60 Hz.3-WireService

POWER

COMPANY

METER

240 VOLT

120 VOLT

120 VOLT

LOADN

NEUTRALBUS

GROUND

PREMISESDISCONNECT AND

SERVICEOVERCURRENT

PROTECTION

GND

N

NOTE: No. 6 COPPER CONDUCTOR CABLE SEENATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE

SIZE RECOMMENDATIONS.

240 VOLT

GROUNDED CONDUCTOR

40 AMP240 VOLT

DOUBLEPOLE

CIRCUITBREAKER

DOUBLE POLE DOUBLE THROWSWITCH RATING TO BE THE SAMEAS OR GREATER THAN PREMISESSERVICE OVERCURRENTPROTECTION.

50 AMP, 120/240VOLT PLUG

NEMA TYPE 14-50

50 AMP, 120/240 VOLTRECEPTACLE

A-9INSTALLATION

EAGLE 10,000

A-9

Connection of EAGLE 10,000 to premises wiringmust be done by a licensed electrician and mustcomply with the National Electrical Code and allother applicable electrical codes.

Figure 1

CONNECTION OF EAGLE 10,000 TO PREMISES WIRING

WARNING

WELDER CONTROLS - FUNCTION ANDOPERATION

ENGINE SWITCHThe engine switch is used to Start the Engine, SelectHigh Idle or Auto Idle while the engine is running, andstop the Engine.

When placed in the “OFF” position, the ignitioncircuit is de-energized to shut down the engine.

When held in the “START” position, the enginestarter motor is energized.

When in “HIGH IDLE” ( ) position, the engine willrun continuously at high idle.

When in “AUTO IDLE” ( / ) position, theengine will run continuously and the idler operates asfollows:

• Welding

When the electrode touches the work, the welding arc is initiated and the engine accelerates to fullspeed.

After welding ceases (and no auxiliary power isbeing drawn), the engine will return to low idleafter approximately 10 to 14 seconds.

• Auxiliary Power

With the engine running at low idle and auxiliarypower for lights or tools is drawn (approximately100-150 watts or greater) from the receptacles,the engine will accelerate to high speed. If nopower is being drawn from the receptacles (andnot welding) for 10-14 seconds, the idler reducesthe engine speed to low idle.

B-1OPERATION

EAGLE 10,000

B-1

SAFETY PRECAUTIONS

Do not attempt to use this equipment until youhave thoroughly read the engine manufacturer’smanual supplied with your welder. It includesimportant safety precautions, detailed enginestarting, operating and maintenance instructions,and parts lists.------------------------------------------------------------------------

ELECTRIC SHOCK can kill.• Do not touch electrically live parts or

electrode with skin or wet clothing.• Insulate yourself from work and

ground• Always wear dry insulating gloves.

• Always operate the welder with the hinged doorclosed and the side panels in place.

• Read carefully the Safety Precautions pagebefore operating this machine. Always followthese and any other safety procedures includedin this manual and in the Engine InstructionManual.

------------------------------------------------------------------------

GENERAL DESCRIPTIONThe EAGLE™10,000 is a twin-cylinder, gasoline dri-ven, multiprocess arc welder and AC power genera-tor. It is built in a heavy gauge steel case for durabilityon the job site.

“ RANGE” SWITCH

Never change the “RANGE” Switch setting whilewelding. This will damage the switch.------------------------------------------------------------------------

“ CONTROL” DIAL

Provides a fine welding current adjustment within theRange Switch settings.

B-2OPERATIONB-2

EAGLE 10,000

CAUTION

KOHLER20 H.P. COMMAND

.39 Gallons/Hour(1.49 Liters/Hour).74 Gallons/Hour(2.79 Liters/Hour)1.22 Gallons/Hour(4.63 Liters/Hour)1.29 Gallons/Hour(4.87 Liters/Hour)1.18 Gallons/Hour(4.48 Liters/Hour)

1.40 Gallons/Hour)(5.31 Liters/Hour)

Low Idle - No Load2200 RPMHigh Idle - No Load3700 RPMAC CC Weld Output225 Amps @ 25 VoltsDC CC Weld Output210 Amps @ 25 VoltsDC CV Weld Output200 Amps @ 20 VoltsAuxiliary Power9000 Watts

EAGLE 10,000 APPROXIMATE FUEL CONSUMPTION

Process Range Setting Current RangeSTICK/TIG

(constant current)(3 range settings)

90 Max.145 Max.210 Max.

50 to 90 Amps70 to 145 Amps120 to 210 Amps

B-3OPERATIONB-3

STARTING/SHUTDOWN INSTRUCTIONSSTARTING THE ENGINE

Be sure all Pre-Operation Maintenance has been per-formed. Also, read the Engine Owner’s Manual beforestarting for the frist time.

Remove all loads connected to the AC power recepta-cles. Use the choke control as follows:

KOHLER ENGINE - Always pull the choke control outwhen starting the engine; cold, warm or hot.

Turn the engine switch to the “start” position andcrank the engine until it starts. Release the switch assoon as the engine starts, slowly return the chokecontrol to the full “in” position (choke open), and turn the switch to the Auto Idle( / ) position. Do not turn the switch to the “start” positionwhile the engine is running because this will causedamage to the ring gear and/or starter motor

After running at high engine speed for 10-14 seconds,the engine will go to low idle.Allow the engine to warm up by letting it run at low idlefor a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads andallow engine to run at low idle speed for a few minutesto cool the engine.

Stop the engine by placing the Engine switch in the

“OFF” position.

A fuel shut off valve is not required on the EAGLE10,000 because the fuel tank is mounted below the

engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount ofoil until the break-in is accomplished. Check the oillevel twice a day during the break-in period (approxi-mately 50 running hours).

IMPORTANT: IN ORDER TO ACCOMPLISH THISBREAK-IN, THE UNIT SHOULD BESUBJECTED TO MODERATE LOADS, WITHIN THE RATING OFTHE MACHINE. AVOID LONG IDLERUNNING PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL BEFORE SHUTDOWN.

The engine manufacturer’s recommendation for therunning time until the first oil change is as follows:

The oil filter is to be changed at the second oilchange. Refer to the Engine Owner’s Manual orMaintenance section of this manual for more informa-tion.

EAGLE 10,000

• Do not touch electrically live partsof electrode with skin or wetclothing.

• Keep flammable material away.

• Insulate yourself from work andground. Wear eye, ear, and bodyprotection.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

WARNING

KOHLERCH20S

5 HRS

ARC GOUGING

The EAGLE 10,000 can be used for limited arc goug-ing.

Set the Range switch to adjust output current to thedesired level for the gouging electrode being usedaccording to the ratings in the following table:

B-4OPERATIONB-4

WELDING PROCESSFor any electrodes the procedures should be keptwithin the rating of the machine. For electrode infor-mation see the appropriate Lincoln publication.

Stick (Constant Current) WeldingConnect welding cables to the “+” and “-” studs. Startthe engine. The “RANGE” switch markings indicatethe maximum current for that range as well as the typ-ical electrode size for that range. The “OUTPUT”Control provides fine adjustment of the welding cur-rent within the select range. For maximum output with-in a selected range set the “OUTPUT” Control at 10.For minimum output within a selected range set the“OUTPUT” Control at 5. (“OUTPUT” Control settingsbelow 5 may reduce arc stability) For best overallwelding performance set the “RANGE” Switch to thelowest setting and the OUTPUT” Control near themaximum to achieve the desired welding current.

RANGE SETTING TYPICAL CURRENT RANGEELECTRODE SIZE

WIRE FEED WELDING PROCESSES(CONSTANT VOLTAGE)

The Innershield® electrode recommended for use withthe EAGLE 10,000 is NR®-211-MP. The electrodesizes and welding ranges that can be used with theEAGLE 10,000 are shown in the following table:

The EAGLE 10,000 is recommended for limited “MIG”welding (GMAW - gas metal arc welding). The recom-mended electrodes are .030” and .035” L-50 and L-56.They must be used with a blended shielding gas suchas C25 (75% Argon - 25% CO2). The welding rangesthat can be used with the EAGLE 10,000 are shown inthe following table:

EAGLE 10,000

Diameter Wire Speed Approximate(in.) Range In./Min. Current Range

.035 80 - 110 75A to 120A

.045 70 - 130 120A to 170A

.068 40 - 90 125A to 210A

Diameter Wire Speed Approximate(in.) Range In./Min. Current Range

.030 75 - 300 50A to 130A

.035 100 - 250 80A to 175A

90 MAX.

145 MAX.

210 MAX.

3/32

1/8

5/32

50 TO 90 AMPS

70 TO 145 AMPS

120 TO 210 AMPS

TIG (CONSTANT CURRENT) WELDING

The K930-[ ] TIG Module installed on a EAGLE10,000 provides high frequency and shielding gascontrol for GTAW (TIG) welding processes. OutputControl is from the Eagle 10,000. The control on theTIG Module is not functional. After flow time isadjustable from 0 to 55 seconds. A K814 Arc StartSwitch is required.

The K930-[ ] TIG Module should be used with theEAGLE 10,000 on HIGH IDLE to maintain satisfactoryoperation. It can be used in the AUTO position but thedelay going to flow idle after welding is ceased will beincreased if the AFTER FLOW CONTROL is setabove 10 seconds. A K814 Arc Start Switch isrequired.

Carbon Diameter CURRENT RANGE (DC, electrode positive)

1/8 60 - 90 Amps5/32 90 - 250 Amps

B-5OPERATIONB-5

EAGLE 10,000

SUMMARY OF WELDING PROCESSES

CONTROL ELECTRODECABLE IDLE WHEN NOT TO START

PROCESS USED MODE WELDING WELDING

STICK No AUTO Hot Touch electrode to work.Welding starts immediatelyand engine goes to highidle.

WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25INTERNAL CONTACTOR contactor closes. Welding

starts immediately andengine goes to high idle.NOTE: Output Control must be set above “3”

TIG, TIG MODULE WITH Yes High Cold Press Arc Start SwitchWITH CONTACTOR KIT contactor closes,CONTROL CABLE, & ARC welding starts immediately.START SWITCH

WIRE FEED, LN-15 No AUTO Cold Press gun trigger.ACROSS the ARC LN-15 contactor closes,(has internal contactor) Welding starts immediately

Note: Output Control must be set above “3”.

TYPICAL CURRENT RANGES (1) FOR TUNGSTEN ELECTRODES(2)

Tungsten Electrode DCEN (-) DCEP (+) Approximate Argon Gas Flow TIG TORCH

Diameter in. (mm) Flow Rate C.F.H. ( l /min.) Nozzle Size (4), (5)

1%, 2% Thoriated 1%, 2% Thoriated Aluminum Stainless SteelTungsten Tungsten

.010 (.25) 2-15 (3) 3-8 (2-4) 3-8 (2-4) #4, #5, #60.020 (.50) 5-20 (3) 5-10 (3-5) 5-10 (3-5)0.040 (1.0) 15-80 (3) 5-10 (3-5) 5-10 (3-5)

1/16 (1.6) 70-150 10-20 5-10 (3-5) 9-13 (4-6) #5, #6

3/32 (2.4) 150-250 15-30 13-17 (6-8) 11-15 (5-7) #6, #7, #81/8 (3.2) 250-400 25-40 15-23 (7-11) 11-15 (5-7)

5/32 (4.0) 400-500 40-55 21-25 (10-12) 13-17 (6-8) #8, #103/16 (4.8) 500-750 55-80 23-27 (11-13) 18-22 (8-10)1/4 (6.4) 750-1000 80-125 28-32 (13-15) 23-27 (11-13)

(1) When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.(2) Tungsten electrodes are classified as follows by the American Welding Society (AWS):

Pure EWP1% Thoriated EWTh-12% Thoriated EWTh-2

Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.(3) DCEP is not commonly used in these sizes.(4) TIG torch nozzle "sizes" are in multiples of 1/16ths of an inch:

# 4 = 1/4 in. (6 mm)# 5 = 5/16 in. (8 mm)# 6 = 3/8 in. (10 mm)# 7 = 7/16 in. (11 mm)# 8 = _ in. (12.5 mm)#10 = 5/8 in. (16 mm)

(5) TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high temperaturesand high duty cycles.

C-1ACCESSORIESC-1

EAGLE 10,000

OPTIONAL EQUIPMENT (Field Installed)

K957-1 HEAVY DUTY, TWO WHEEL TRAILER FORSMALL WELDERS - For road, off-road and in-plantand yard towing. (For highway use, consult applicablefederal, state and local laws regarding requirementsfor brakes, lights, fenders, etc.)Order K957-1 Trailer

K958-1 Ball HitchK958-2 Lunette Eye HitchK959-2 Fender & Light KitK965-1 Cable Storage Rack

K889-2 & -3 Two-Wheel Undercarriage - For movingby hand. Overall Width 29 in (.74m) Both have pneu-matic tires. Puncture proof tires included with K889-3.

K1631-1 Puncture Proof Wheel Kit - For convertingK889-2 or K933-1 to puncture proof pneumatic tires.

K893-1 Caster for Undercarriage - Mounts to thefront of the K889-2 or 3 to allow easy movement onsmooth surfaces. Includes 6” diameter hard rubberwheel and convenient toe-on, toe-off locking brake.

K933-1 Four Wheel Undercarriage - For HandMoving. Rear pneumatic tires, front molded wheels.

K934-1 Cylinder Brackets - For use with K933-1. Fortransporting one welding gas cylinder.

K1737-1 FOUR WHEEL ALL-TERRAIN UNDER-CARRIAGE - For moving by hand at constructionsites. Heavy duty puncture resistant pneumatic tires.

K1770-1 UNDERCARRIAGE (FACTORY) - For mov-ing by hand on a smooth surface. One or two gascylinders can be mounted on the rear of the undercar-riage with the installation of K1745-1 CylinderHolder(s). Heavy duty puncture resistant pneumatictires and front caster.

K1745-1 GAS CYLINDER HOLDERHolds Welding Gas Cylinder for use on K1770-1Undercarriage. One or two may be installed on anundercarriage.

K1788-1 ROLL CAGE - Gives added damage protection.Attaches to K1737-1, K1770-1, and K957-1.

K886-1 Canvas Cover -To protect the EAGLE 10,000when not in use. Made from attractive red canvasmaterial which is flame retardant, mildew resistant,and water repellent.

K802-R Power Plug Kit- provides four 120V plugsrated at 15 amps each and one dual voltage, FullKVA plug rated at 120/240V, 50 amps.

K802-N Power Plug Kit - Provides four 120V plugs rated at 20amps each and one dual voltage, full KVA plug rated at 120/240V,50 amps.

K704 Accessory Kit - Includes 35 ft (10.7m) 2/0 AWG electrodecable, 30 ft. (9.1m) 2/0 AWG work cable, headshield with filter plate,work clamp and electrode holder. 400 amps capacity.

K875 Accessory Kit -Includes 20 ft (6.1m) #6 electrode cable withlug, 15 ft. (4.6 m) #6 work cable with lugs,headshield with filterplate, work clamp and electrode holder and sample pack of mildsteel electrode, 150 Amp Capacity.

K894-1 Spark Arrester Kit - Includes a heavy gauge steel,approved spark arrester and clamp for easy mounting to mufflerexhaust pipe.

K1690-1 GFCI RECEPTACLE KIT - Includes one UL approved 120Vground fault circuit interrupter duplex type receptacle with cover andinstallation instructions. Replaces the factory installed 120V duplexreceptacle. Each receptacle of the GFCI Duplex is rated at 20 Amps,the maximum total current from the GFCI Duplex is limited to the 20Amps. Two kits are required.

K1816-1 FULL KVA ADAPTER KIT - Plugs into the 120/240VNEMA 14-50R receptacle on the case front (which accepts 4-prongplugs) and converts it to a NEMA 6-50R receptacle, (which accepts3-prong plugs.)

T12153-9 FULL-KVA Power Plug - One dual voltage plug rated at120/240V, 50 amps.

K930-2 TIG Module - Provides high frequency and shielding gascontrol.for DC GTAW (TIG) welding applications. Its compact caseis designed for easy carrying, complete with a handle. High frequen-cy bypass is built inRequires K938-1 Contactor Kit, K936-4 Control Cable, and K814Arc Start Switch.

K938-1 Contactor Kit - For use with TIG Module, Provides a “cold”electrode until the triggering device (Arc Start Switch) is pressed.

K936-4 Control Cable - Connects TIG Module to EAGLE 10,000.

K814 Arc Start Switch - Attaches to the TIG torch for convenient fin-ger control.

K937-45 Control Cable Extension - Allows TIG Module to be operat-ed at distances up to 200ft. from the power source. Available in 45ft.(13.7m).

K844-1 Water Valve Kit - For use with water cooled TIG torch,Installs inside of TIG Module.

K939-1 Docking Kit - For Mounting the K930-2 TIG Module on topof the EAGLE 10,000.

C-2ACCESSORIESC-2

RECOMMENDED EQUIPMENT

STICK

K704(400 Amp) or K875(150 Amp)Accessory Kitwhich includes:

• Electrode Holder & Cable• Work Clamp & Cable• Headshield

WIRE FEED

K449 LN-25 - Includes internal contactor for acrossthe arc operation (no control cable). Provides “cold”electrode until gun trigger is pressed. Includes gassolenoid.

K1870-1 LN-15 Across the Arc Wire Feeder.Portable, lightweight, compact CC/CV unit for flux-cored and MIG welding. Includes Gas Solenoid,adjustable flow meter and internal contactor. For 10-15 lb. (4.5-6.8kg) spools.

Magnum Gun and Magnum Gun Connector Kit arerequired for gas-shielded welding. Innershield Gun isrequired for gasless welding.

K126-2 Magnum 350 Innershield GunK1802-1 Magnum 300 MIG Gun (for LN-25)K470-2 Magnum 300 MIG Gun (for LN-15)(Includes

Connector Kit)K466-10 Connector Kit (for LN-15, K470-2)K1500-1 Gun Receiver Bushing (for LN-15 & K126-2)

TIG

K1783-9 Pro -Torch® PTA-26V TIG TorchAir Cooled 200 amp torch (2 piece) equipped withvalve for gas flow control. 25 ft. (7.6m) length.

KP509 Magnum Parts Kit for PTA-26V TIG TorchMagnum Parts Kit provides all the torch accessoriesyou need to start welding. Parts kit provides collets,collet bodies, a black cap, alumina nozzles and tung-stens in a variety of sizes, all packaged in an easy tocarry reclosable sack.

K930-2 TIG ModuleRequires K938-1 Contactor Kit,K936-4 Control Cable, and K814Arc Start Switch

Optional TIG Equipment:K939-1 Docking KitK937-45 Control Cable ExtensionsK844-1 Water Valve Kit

PLASMA CUTTING

K1580-1 Pro-Cut 55Cuts mild steel using the 3-phase AC generator powerfrom the engine driven welder. Accepts 3-phase or 1-phase input power. Requires the K1816-1 Full KVAadapter kit, if connected for 1-phase input power.

EAGLE 10,000

Have qualified personnel do the maintenancework. Turn the engine off before working insidethe machine. In some cases, it may be necessaryto remove safety guards to perform requiredmaintenance. Remove guards only whennecessary and replace them when the mainte-nance requiring their removal is complete.Always use the greatest care when working nearmoving parts.

Do not put your hands near the engine coolingblower fan. If a problem cannot be corrected byfollowing the instructions, take the machine tothe nearest Lincoln Field Service Shop.

-----------------------------------------------------------------------ELECTRIC SHOCK can kill.• Do not touch electrically live parts

or electrode with skin or wetclothing.

• Insulate yourself from work andground

• Always wear dry insulating gloves.------------------------------------------------------------------------

ENGINE EXHAUST can kill.• Use in open, well ventilated areas

or vent exhaust outside.

------------------------------------------------------------------------MOVING PARTS can injure.• Do not operate with doors open or

guards off.• Stop engine before servicing.• Keep away from moving parts.

------------------------------------------------------------------------See additional warning informationthroughout this operator’s manual andthe Engine manual as well.

------------------------------------------------------------

Make certain that the oil filler cap is securely tight-ened after checking or adding oil. If the cap is nottight, oil consumption can increase significantlywhich may be evidenced by white smoke comingfrom the exhaust.

• OIL - Maintenance schedule for changing the oil andoil filter after break-in :

The above schedule is for normal operating condi-tions. More frequent oil changes are required withdusty, high temperature and other severe operatingconditions. Refer to the maintenance section of theEngine Owner's Manual for more information.

NOTE: Engine life will be reduced if the oil and oilfilter are not changed according to the manufacturer’srecommendation.

ENGINE OIL CHANGE Drain the oil while the engine is warm to assure rapidand complete draining.

• Remove the oil filler cap and dipstick. Remove theyellow cap from the oil drain valve and attach theflexible drain tube supplied with the machine. Pushin and twist the drain valve counterclockwise. Pullthe valve out and drain the oil into a suitable contain-er.

• Close the drain valve by pushing in and twistingclockwise. Replace the yellow cap.

• Refill to the upper limit mark on the dipstick with therecommended oil. Tighten the oil filler cap securely.

ENGINE OIL REFILL CAPACITIESWithout oil filter replacement:• 1.7 US qt. (1.4 Imp qt., 1.6 liter)-Kohler

With oil filter replacement:• 2.0 US qt. (1.7 Imp qt., 1.9 liter)-Kohler

WARNING

D-1MAINTENANCED-1

EAGLE 10,000

SAFETY PRECAUTIONSCAUTION

Read the Safety Precautions in the front of this manualand the engine instruction manual before working onthis machine.

Keep all equipment safety guards, covers, and devicesin position and in good repair. Keep hands, hair, cloth-ing, and tools away from gears, fans, and all othermoving parts when starting, operating, or repairing theequipment.

Routine Maintenance• At the end of each day’s use, refill the fuel tank to

minimize moisture condensation in the tank.Running out of fuel tends to draw dirt into the fuel system. Also, check the crankcase oil level andadd oil if indicated.

KohlerCH20S

Oil 100 Hrs.

Oil Filter 200 Hrs.

D-2MAINTENANCED-2

Use 4-stroke motor oil that meets or exceeds therequirements for API service classification SG or SH.Always check the API SERVICE label on the oil con-tainer to be sure it includes the letters SG or SH.

SAE 10W-30 is recommended for general, all-tempera-ture use, -5 F to 104 F (-20 C to 40 C).

See Engine Owner’s Manual for more specific informa-tion on oil viscosity recommendations.

Wash your hands with soap and water after handlingused oil.

Please dispose of used motor oil in a manner that iscompatible with the environment. We suggest you takeit in a sealed container to your local service station orrecycling center for reclamation.

Do not throw it in the trash, pour it on the ground ordown a drain.

OIL FILTER CHANGE

1. Drain the engine oil.

2. Remove the oil filter, and drain the oil into a suitablecontainer. Discard the used oil filter.

3. Clean the filter mounting base, and coat the gasketof the new oil filter with clean engine oil.

4. Screw on the new oil filter by hand, until the gasketcontacts the filter mounting base, then use an oil fil-ter socket tool to tighten the filter an additional 1/2 to7/8 turn.

5. Refill the crankcase with the specified amount of therecommended oil. Reinstall the oil filler cap.

6. Start the engine and check for oil filter leaks.

7. Stop the engine, and check the oil level. If neces-sary, add oil to the upper limit mark on the dipstick.

AIR CLEANER AND OTHER MAINTENANCE

• Air Cleaner - With normal operating conditions, themaintenance schedule for cleaning and re-oilingthe foam pre-filter is every 25 hours and replace-ment of the air cleaner filter every 100 hours.More frequent servicing is required with dustyoperating conditions. Refer to the maintenancesection of the Engine Owner’s Manual for moreinformation.

• Refer to the maintenance section of the EngineOwner’s Manual for the maintenance schedule,spark plug servicing, cooling system servicing, andfuel filter replacement.

• Blow out the machine with low pressure air period-ically. In particularly dirty locations, this may berequired once a week.

• Output Range Selector: Switch contacts should notbe greased. To keep contacts clean, rotate theswitch through its entire range frequently. Goodpractice is to turn the handle from maximum to min-imum setting twice each morning before starting toweld.

EAGLE 10,000

D-3MAINTENANCED-3

ENGINE ADJUSTMENTS

OVERSPEED IS HAZARDOUS

The maximum allowable high idle speed for thismachine is 3750 RPM, no load. Do NOT tamperwith governor components or setting or make anyother adjustments to increase the maximumspeed. Severe personal injury and damage to themachine can result if operated at speeds abovemaximum.------------------------------------------------------------------------Adjustments to the engine are to be made only by aLincoln Service Center or an authorized Field ServiceShop.

SLIP RINGS

A slight amount of darkening and wear of the slip ringsand brushes is normal. Brushes should be inspectedwhen a general overhaul is necessary.If brushes areto be replaced, clean slip rings with a fine emerypaper.

Do not attempt to polish slip rings while engine isrunning.------------------------------------------------------------------------

BATTERY

1. When replacing, jumping, or otherwise connectingthe battery to the battery cables, the properpolarity must be observed. Failure to observethe proper polarity could result in damage to thecharging circuit. The positive (+) battery cablehas a red terminal cover.

2. If the battery requires charging from an external charger, disconnect the negative battery cablefirst and then the positive battery cable beforeattaching the charger leads. Failure to do socan result in damage to the internal chargercomponents. When reconnecting the cables,connect the positive cable first and the negativecable last.

HARDWAREBoth English and Metric fasteners are used in thiswelder.

EAGLE 10,000

WARNING

GASES FROM BATTERY can explode.• Keep sparks, flame and cigarettesaway from battery.

To prevent EXPLOSION when:• INSTALLING A NEW BATTERY - dis-connect negative cable from old bat-tery first and connect to new batterylast.

• CONNECTING A BATTERY CHARG-ER - Remove battery from welder bydisconnecting negative cable first,then positive cable and battery clamp.When reinstalling, connect negativecable last. Keep well ventilated.

• USING A BOOSTER - connect positive lead tobattery first then connect negative lead to enginefoot.

BATTERY ACID CAN BURN EYES ANDSKIN.• Wear gloves and eye protection andbe careful when working near battery.Follow instructions printed on battery.

-----------------------------------------------------------------------

WARNING

CAUTION

KOHLER C20S

KOHLER 1205001Oil Filter FRAM PH3614*

Air Filter KOHLER 4708303Element FRAM CA79

Air Filter KOHLER 2408302Pre-Cleaner

Fuel Filter KOHLER 2505002FRAM G1

Spark Plugs CHAMPION RC12YC(Resistor (.030” GAP)

Type)

* Oil capacity increases from 2.0 Qts. to 2.1Qts. when using this filter.

ENGINE MAINTENANCE PARTS

E-1TROUBLESHOOTINGE-1

EAGLE 10,000

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

This Troubleshooting Guide is provided to help youlocate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.

Step 1. LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptomsthat the machine may exhibit. Find the listing thatbest describes the symptom that the machine isexhibiting.

Step 2. POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” liststhe obvious external possibilities that may contributeto the machine symptom.

Step 3. RECOMMENDED COURSE OF ACTIONThis column provides a course of action for thePossible Cause, generally it states to contact yourlocal Lincoln Authorized Field Service Facility.

If you do not understand or are unable to perform theRecommended Course of Action safely, contact yourlocal Lincoln Authorized Field Service Facility.

HOW TO USE TROUBLESHOOTING GUIDE

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician andmachine operator and will invalidate your factory warranty. For your safety and to avoid ElectricalShock, please observe all safety notes and precautions detailed throughout this manual.

__________________________________________________________________________

WARNING

E-2TROUBLESHOOTINGE-2

EAGLE 10,000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

POSSIBLECAUSE

RECOMMENDEDCOURSE OF ACTION

No welder or output power.

Engine will not idle down to lowspeed.

Engine will not go to high idle whenattempting to weld.

1. Open in miscellaneous leads.

2. Open lead in flashing or fieldcircuit.

3. Faulty rotor.

4. Faulty Potentiometer (R1).

5. Faulty stator Field winding.

6. Faulty Field rectifier (D2).

7. Faulty P.C. Board.

1. Idler switch on High Idle.

2. Insufficient voltage presentbetween terminals #213 and#5E. (Voltage should be 12VDC).

3. External load on welder orauxiliary power.

4. Faulty wiring in solenoid circuit.

5. Faulty idler solenoid.

6. Faulty P.C. Board.

1. Poor work lead connection towork.

2. No voltage signal from thecurrent sensor.

3. No open circuit voltage on output studs.

4. Faulty P.C. Board.

If all recommended possible areas ofmisadjustment have been checkedand the problem persists, Contactyour local Lincoln AuthorizedField Service Facility.

E-3TROUBLESHOOTINGE-3

EAGLE 10,000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

POSSIBLECAUSE

RECOMMENDEDCOURSE OF ACTION

Engine will not go to high idle whenusing auxiliary power.

Engine will not crank or is hard tocrank.

Engine shuts down.

Engine does not develop full power.

Engine is hard to start.

1. No voltage signal from thecurrent sensor.

2. Auxiliary power load less than100 to 150 watts.

3. Faulty P.C. Board.

1. Battery will not hold a charge.Faulty Battery.

2. No or insufficient chargingcurrent.

3. Loose battery cableconnection(s).

1. Out of fuel.

2. Low oil level.

1. Fuel filter clogged.

2. Air filter clogged.

1. Spark plugs do not havespecified gap.

2. Spark plugs are fouled.

If all recommended possible areas ofmisadjustment have been checkedand the problem persists, Contactyour local Lincoln AuthorizedField Service Facility.

STA

RTE

RC

R1

STA

RTE

R

SO

LEN

OID

12 V

OLT

IDLE

RS

OLE

NO

ID

BA

TTE

RY

AC

AC

B+

SW

ITC

HR

EG

ULA

TOR

FLY

WH

EE

L A

LTE

RN

ATO

RB-

HO

UR

ME

TER

5E5D

224

EN

GIN

E C

OM

PO

NEN

TS224A

12

3

CO

NN

ECTO

R P

IN N

UM

BE

RS

:

7

612

12

34

J1

N.A

.

B

J2

SO

LEN

OID

FUE

LS

HU

TOFF

OIL

PR

ES

SU

RE

TER

MIN

AL

BLO

CK

(SE

E C

ON

N.)

209A

209A

224C

210

BB

GE

NER

ATO

R L

EA

D E

ND

(NO

TE C

AVI

TY N

UM

BE

RS

)

LOC

ATIN

G T

AB

TER

MIN

AL

BLO

CK

CO

NN

ECTI

ON

208

208

(CA

VIT

Y #

2)

211

(CA

VIT

Y #

3)22

4C (C

AVI

TY #

4)

13

24

211

IGN

ITIO

NM

OD

ULE

M20

317

215

+

ELE

CTR

ICA

L S

YM

BOLS

PE

R E

1537

STA

TOR

REA

CTO

R

S1

CH

OKE

D1

RO

TOR

PC

B1

SLI

P R

ING

NE

AR

EST

LAM

INA

TIO

N

W1

W2

C1

S1

R1

R5

L1

-+

+

R3

STA

TOR

REA

CTO

R

+

10 8

1712 6

6

5

39

7

200A

219

3

EN

GIN

EC

RO

SSS

UP

PO

RT

GR

OU

ND

SC

RE

W

GN

D-E

GN

D-E

GN

D-G

200A219

22421576A5E

75A77A

J18 10

5D

254

R1

OU

TPU

TC

ON

TRO

L

75A

76A

77A

75A

77A

76A

ON

UPP

ER

CA

SE

FRO

NT

-

209

+ RR

U

VW

EN

GIN

EFO

OT

GN

D-D

GN

D-C

5F

224A

GN

D-H

TER

MIN

ALS

6

55L

120V

/240

V

5K

GN

D-D

GN

D-C

J4

J3

J2

GN

D-G

55L

5K

120V

120V

12

11

11

3A3A

CB

140

A 40A

CB

2C

B3

20A

20A

CB

4

3

SIL

VE

R C

OLO

RE

D

(WH

ITE

WIR

ES

)

EAG

LE 1

0,00

0 (K

OH

LER

) (C

SA)

A

CC

W

ALL

CA

SE F

RO

NT

CO

MPO

NEN

TS S

HO

WN

VIE

WED

FR

OM

RE

AR.

N.A

. G

RO

UN

DIN

G T

HIS

TE

RM

INA

L S

TOP

S T

HE

EN

GIN

E.

210

CB

725

A

R =

RE

D O

R P

INK

B =

BLA

CK

OR

GR

AY

V =

VIO

LET

U =

BLU

E

W =

WH

ITE

LEA D

CO

LOR

CO

DE

:

254

3

12

34

261

260

1 TU

RN

211

213

208C

6A

6

LEAD

S 3

AND

6:

2 TU

RNS

THR

U T

ORO

ID IN

OPP

OSI

TE D

IREC

TIO

NS

6

67

9

J2

S2E

GN

D-I

P5

J5

GR

OUN

D SC

REW

ON

LO

WER

CAS

EFR

ON

T

S3

3B

6B-+

213A

213A

213A

F-1DIAGRAMSF-1

EAGLE 10,000

NO

TE

: T

his

dia

gra

m is

fo

r re

fere

nce

onl

y.

It m

ay n

ot

be

accu

rate

fo

r al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m f

or

a p

artic

ular

co

de

is p

aste

d in

sid

eth

e m

achi

ne o

n o

ne o

f th

e en

clo

sure

pan

els.

If

the

dia

gra

m is

ille

gib

le, w

rite

to

the

Ser

vice

Dep

artm

ent

for

a re

pla

cem

ent.

Giv

e th

e eq

uip

men

t co

de

num

ber

.

F-2DIAGRAMSF-2

EAGLE 10,000

EAG

LE 1

0,00

0 / L

N-25

ACR

OSS

THE

ARC

CO

NNEC

TIO

N DI

AGRA

M

ELE

CT

RIC

SH

OC

K c

an k

illD

o no

t ope

rate

with

pan

els

open

.D

isco

nnec

t NE

GA

TIV

E (-

) Bat

tery

lead

befo

re s

ervi

cing

.D

o no

t tou

ch e

lect

rical

ly li

ve p

arts

.WA

RN

ING M

OV

ING

PA

RT

S c

an in

jure

Kee

p gu

ards

in p

lace

.K

eep

away

from

mov

ing

parts

.O

nly

qual

ified

per

sonn

el s

houl

d in

stal

l,use

or s

ervi

ce th

is e

quip

men

t.

M20

295

A.01

N.A

. W

ELD

ING

CAB

LE M

UST

BE S

IZED

FO

R C

URR

ENT

DUTY

CYC

LE O

F AP

PLIC

ATIO

N

LN-2

5W

IRE

FEED

ER

TO W

OR

K

ELEC

TRO

DE

CAB

LE

WO

RK C

LIP

LEAD

F-3DIAGRAMSF-3

EAGLE 10,000

A.

A.

01

26.5

9

30.2

7

9.09

9.09

17.0

0

21.2

2

8.80

30.0

0

42.0

0

22.1

5

10.3

3

CEN

TER

OF

GRA

VITY

WIT

H O

IL IN

ENG

INE

AND

FU

LL F

UEL

TAN

K9.

31

CEN

TER

LIN

E O

F SH

AFT

9.59

10.1

9

OIL

FIL

TER

REM

OVA

L

EA

GLE

10,

000

EA

GLE

10,0

00

NOTES

EAGLE 10,000

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BEUSED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOSCONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS AETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

● Do not touch electrically live parts orelectrode with skin or wet clothing.

● Insulate yourself from work andground.

● No toque las partes o los electrodosbajo carga con la piel o ropa moja-da.

● Aislese del trabajo y de la tierra.

● Ne laissez ni la peau ni des vête-ments mouillés entrer en contactavec des pièces sous tension.

● Isolez-vous du travail et de la terre.

● Berühren Sie keine stromführendenTeile oder Elektroden mit IhremKörper oder feuchter Kleidung!

● Isolieren Sie sich von denElektroden und dem Erdboden!

● Não toque partes elétricas e elec-trodos com a pele ou roupa molha-da.

● Isole-se da peça e terra.

● Keep flammable materials away.

● Mantenga el material combustiblefuera del área de trabajo.

● Gardez à l’écart de tout matérielinflammable.

● Entfernen Sie brennbarres Material!

● Mantenha inflamáveis bem guarda-dos.

● Wear eye, ear and body protection.

● Protéjase los ojos, los oídos y elcuerpo.

● Protégez vos yeux, vos oreilles etvotre corps.

● Tragen Sie Augen-, Ohren- und Kör-perschutz!

● Use proteção para a vista, ouvido ecorpo.

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.

● Keep your head out of fumes.● Use ventilation or exhaust to

remove fumes from breathing zone.

● Los humos fuera de la zona de res-piración.

● Mantenga la cabeza fuera de loshumos. Utilice ventilación oaspiración para gases.

● Gardez la tête à l’écart des fumées.● Utilisez un ventilateur ou un aspira-

teur pour ôter les fumées des zonesde travail.

● Vermeiden Sie das Einatmen vonSchweibrauch!

● Sorgen Sie für gute Be- undEntlüftung des Arbeitsplatzes!

● Mantenha seu rosto da fumaça.● Use ventilação e exhaustão para

remover fumo da zona respiratória.

● Turn power off before servicing.

● Desconectar el cable de ali-mentación de poder de la máquinaantes de iniciar cualquier servicio.

● Débranchez le courant avant l’entre-tien.

● Strom vor Wartungsarbeitenabschalten! (Netzstrom völlig öff-nen; Maschine anhalten!)

● Não opere com as tampas removidas.● Desligue a corrente antes de fazer

serviço.● Não toque as partes elétricas nuas.

● Do not operate with panel open orguards off.

● No operar con panel abierto oguardas quitadas.

● N’opérez pas avec les panneauxouverts ou avec les dispositifs deprotection enlevés.

● Anlage nie ohne Schutzgehäuseoder Innenschutzverkleidung inBetrieb setzen!

● Mantenha-se afastado das partesmoventes.

● Não opere com os paineis abertosou guardas removidas.

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •