IFX-M4-01
IFX-M4-01_D_E_2017_04_REV.0
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 2 di 18
Table of contents PRINCIPLE ..................................................................................................................................... 4
HOW TO ORDER ............................................................................................................................ 4
TECHNICAL DATA ........................................................................................................................... 5
Table 1.1 .................................................................................................................................... 6
Table 1.2 .................................................................................................................................... 7
Table 1.3 .................................................................................................................................... 7
Straight pipelines lengths ............................................................................................................. 7
Annex A ......................................................................................................................................... 8
Electrical wiring diagrams ............................................................................................................ 8
Fig.A1. Electrical wiring diagram ............................................................................................... 8
Fig.A2. Wiring diagrams for connecting of the sensor to the external power supply ....................... 9
able A1. Numbering of terminals .................................................................................................. 9
Annex B ........................................................................................................................................10
Fig. B1. Mechanical dimensions of electronic unit of the flow sensor ...........................................10
Fig.B2. Sizes and dimensions of the flow sensor ........................................................................10
Fig.B2.1. ................................................................................................................................10
Threaded end connections G3/4“ .............................................................................................10
.............................................................................................................................................11
Fig.B2.2. Threaded end connections G1“ ..................................................................................11
Fig.B2.3. Threaded end connections G1“(a); Flanged end connection DN20 (b) ...........................11
a) Threaded end connections G1 1/4 ..................................................................................12
b) Flanged end connection DN25 ............................................................................................13
c) Flanged end connection DN32 .............................................................................................13
Fig.B2.4. Threaded end connections G1 1/4“(a); Flanged end connection DN25 (b); ....................13
Fig.B2.5. Threaded end connections G2“(a); flanged end connection DN40 (b; c) (two design options) .................................................................................................................................14
a) Dimensions of flow sensors DN50, DN65, DN80, DN100 (Brass housing) ............................15
b) Dimensions of flow sensors DN65, DN80, DN100 (Steel housing) ......................................15
Fig. B2.6. Dimensions of flow sensors DN50, DN65, DN80, and DN100 .......................................15
Annex C ........................................................................................................................................15
Security sealing .........................................................................................................................15
Fig.C1. Sealing of the electronic unit of the flow sensor .............................................................15
Fig.C2. Sealing of the measuring section of the flow sensor (a;b;c;d;e - 1- manufacturer’s adhesive seal-sticker on the bolts of the cover; f – manufacturer’s hanging seal) .......................................16
3 di 18 IFX-M4-01_D_E_2017_04_REV.0
For EU Customers only - WEEE Marking. Marking of electrical and electronic equipment in accordance with Article 14 (2) of Directive 2012/19/EU
This symbol on the product indicates that it will not be treated as household waste. It must be handed over to the applicable take-back scheme for the recycling of electrical and electronic equipment. For more detailed information about the recycling of this product, please contact your local municipal office.
EU DIRECTIVES - DECLARATION OF CONFORMITY
ISOIL Industria“ herewith declares, that this product complies with the relevant requirements of the following directives:
2014/32/EU 2014/30/EU 2014/35/EU
Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the member states relating to the making available on the market of measuring instruments Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
EC-type examination certificate: LT-1621-MI004- 009 rev.1
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 4 di 18
PRINCIPLE Ultrasonic flow meters measure the difference of the transit time of ultrasonic pulses propagating in and against flow direction. This time difference is a measure for the average velocity of the fluid along the path of the ultrasonic beam.
HOW TO ORDER Meter Type
IFX-M4-01 _ _ _ _ * _ * _ * _*
Ratio of flow-rate limits (qp/qi):
100 1
250 (with the exeptions of sensors qp0,6 m3/h; 1,0 m3/h; 3,5 m3/h)
2
Flow sensor: Connection ; length mm ; qi/qp/qs m3/h
G3/4 - 110 - 0,006/0,6/1,2 ## 1 ## 10
G3/4 - 110 - 0,01/1,0/2,0 ## 2 ## 11
G3/4 - 110 - 0,015/1,5/3,0 ## 3 ## 12
G3/4 - 165 - 0,015/1,5/3,0 ## N ## 09
G 1 - 130 - 0,015/1,5/3,0 ## M ## 14
G 1 - 130 - 0,025/2,5/5,0 ## 4 ## 20
G 1 1/4 - 260 - 0,035/3,5/7 ## 5 ## 25
G 1 1/4 - 260 - 0,06/6,0/12 ## 6 ## 32
G 2 - 300 - 0,1/10/20 ## 7 ## 40
DN40FL - 300 - 0,1/10/20 ## 8 ## 41
DN50FL - 270 - 0,15/15/30 ## 9 ## 50
DN25FL - 260 - 0,035/3,5/7 ## A ## 26
DN25FL - 260 - 0,06/6,0/12 ## O ## 33
G1 - 190 - 0,006/0,6/1,2 ## C ## 06
G 1 - 190 - 0,01/1,0/2,0 ## D ## 13
G 1 - 190 - 0,015/1,5/3,0 ## E ## 17
G 1 - 190 - 0,025/2,5/5 ## F ## 22
DN20FL - 190 - 0,006/0,6/1,2 ## G ## 19
DN20FL - 190 - 0,01/1,0/2,0 ## H ## 23
DN20FL - 190 - 0,015/1,5/3,0 ## H ## 24
DN20FL - 190 - 0,025/2,5/5 ## L ## 21
DN32FL - 260 - 0,035/3,5/7 ## O ## 35
DN32FL - 260 - 0,06/6,0/12 ## P ## 34
DN65FL - 300 - 0,25/25/50 ## R ## 65
DN65FL SS - 300 - 0,25/25/50 ## R(SS) ## 65SS
DN80FL - 350 - 0,4/40/80 ## S ## 80
DN80FL SS - 350 - 0,4/40/80 ## S(SS) ## 80SS
DN100FL - 350 - 0,6/60/120 ## T ## 100
DN100FL SS - 350 - 0,6/60/120 ## T(SS) ## 100SS
SENSORS
5 di 18 IFX-M4-01_D_E_2017_04_REV.0
Length of the connection cable between measuring section and electronic unit:
None 0
1,2 m 1
2,5 m 2
5.0 m 3
Pulse value of the flow sensor MN 10 m3/pulse*
* - where N- possible number 1...9, M – possible number 1...6. NM
Supply voltage
Internal battery PN16 1
External power supply 24V Ac/DC PN16 2
Internal battery PN25 3
External power supply 24V Ac/DC PN25 4
Connection cable length between electronic and flow sensor
1.2 m 1
2.5m 2
5.0 m 3
Length of the pulse output device connection cable, m:
3; 5; 10; 15... 200, 0 (or omitted) - none 0
Remark: * - marked numbers are used only for order coding. (It is not used for meter marking).
TECHNICAL DATA
STANDARD FEATURES Suitable for ISONRG (different to be verified)
Range DN25 to DN100 – MI004 (non MID up to DN600 on request) see table 1.1
Version Flow sensor with electronic on board (connection cable with different length, see
HOW TO ORDER – Connection cable length between electronic and flow sensor )
Power Supply Internal size AA, 3,6 V, 2,4 Ah, lithium battery (Li-SOCl2); external 12 V…42 V DC or 12 V…36 V,50/60 Hz AC,10 mA max
Pressure PN16 standard (PN25 on request)
Temperature Electronic Unit: +5°C to +55°C; Sensor: -30°C to 55°C; Conveying fluid: 5°C....130 °C
Humidity Range < 93
Environmental
class
Class C according to EN1434
Mechanical environment
class
M1
Electromagnetic environment
class
E2
Accuracy EN1434 (class 2); Ef = (2+0,02qp/q)
Technology Transit time method
Protection Rate IP65 (IP67 on request for wet parts)
Output Pulse output with different value due to the DN (see table 1.2)
Class of flow
output device
OD according to EN1434-2+AC: 2007
Mechanical data
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 6 di 18
Dimensions of electronic unit,
not more than
117 mm x 44 mm x 89,5 mm
Dimensions of
flow sensors
According to Annex B
Weight According Table 1.3
Material Housing:PA6 (Polyamide) Wet Part:Up to DN50 brass; from DN65 painted stainless steel
Sensors: DN15 and DN20 plastic; others Titanium
Warranty and approvals Warranty 12 months
MID approval MI004
CE certification YES
Table 1.1 Limits of flow rate, m3/h Threshold
value of flow rate,
m3/h
Overall length L, mm
Pressure losses at qp, kPa
Joining to the pipeline
(Thread – G, flange–DN)
Permanent flow rate qp, m3/h
Upper flow rate qs, m3/h
Lower flow rate qi, m3/h
0,6 1,2 0,006 0,003 110 7 G3/4“
0,6 1,2 0,006 0,003 190 0,9 G1“, DN20
1,0 2,0 0,01 0,005 110 11,3 G3/4“
1,0 2,0 0,01 0,005 190 2,5 G1“, DN20
1,5 3,0 0,006 0,003 110; 165
17,1 G3/4“
1,5 3,0 0,006 0,003 190 5,8 G1“, DN20
1,5 3,0 0,015 0,003 110; 165
17,1 G3/4“
1,5 3,0 0,015 0,003 190 5,8 G1“, DN20
1,5 3,0 0,015 0,005 130 7,2 G1“
2,5 5,0 0,01 0,005 130 19,8 G1“
2,5 5,0 0,01 0,005 190 9,4 G1“, DN20
2,5 5,0 0,025 0,005 130 19,8 G1“
2,5 5,0 0,025 0,005 190 9,4 G1“, DN20
3,5 7,0 0,035 0,017 260 4 G1 1/4“,DN25,DN32
6,0 12,0 0,024 0,012 260 10 G1 1/4“,DN25,DN32
6,0 12,0 0,06 0,012 260 10 G1 1/4“,DN25,DN32
10,0 20,0 0,04 0,02 300 18 G2“, DN40
10,0 20,0 0,100 0,02 300 18 G2“, DN40
15,0 30,0 0,06 0,03 270 12 DN50
15,0 30,0 0,15 0,03 270 12 DN50
25 50 0,1 0,05 300 20 DN65
25 50 0,25 0,05 300 20 DN65
40 80 0,16 0,08 350 18 DN80
40 80 0,4 0,08 350 18 DN80
60 120 0,24 0,12 350 18 DN100
60 120 0,6 0,12 350 18 DN100
7 di 18 IFX-M4-01_D_E_2017_04_REV.0
Table 1.2 Permanent flow rate qp, m3/h 0,6 1
1,5 2,5 3,5 6 10
15 25
40 60
Permissible minimal pulse value of volume, l/pulse
0,01
0,01
0,02
0,05
0,1 0,1 0,2 0,5 1
Standard pulse value, l/pulse, usually on stock
0,1 0,1 0,1 0,1 0,1 0,1 1 1 1
Table 1.3 Connection type and mounting length in mm of flow sensor
Weight of sensor, not more than, kg
G3/4“ , 110 mm 0,7
G3/4“ , 165 mm 0,8
G1“ , 130 mm 0,8
G1“ , 190 mm 0,9
DN20 , 190 mm 2,5
G1 ¼“ , 260 mm 3,2
DN25, 260 mm 5,6
DN32, 260 mm 6,1
G2“, 300 mm 3,7
DN40, 300 mm 6,8
DN50, 270 mm 8,5
DN65, 300 mm 13,0
DN80, 350 mm 15,0
DN100, 350 mm 18,0
Straight pipelines lengths
For flow sensors with nominal diameter DN65 to DN100 MID (DN600 NO MID) necessary straight pipelines lengths are:
- UPSTREAM: ≥5 X DN - DOWNSTREAM: ≥ 3 X DN
For flow sensors of other sizes the straight pipelines installation in upstream and downstream the sensor are not necessary.
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 8 di 18
Annex A Electrical wiring diagrams
Fig.A1. Electrical wiring diagram
9 di 18 IFX-M4-01_D_E_2017_04_REV.0
Fig.A2. Wiring diagrams for connecting of the sensor to the external power supply
Table A1. Numbering of terminals
Terminal No.
Destination
18 Output pulses of volume (+)
19 GND (-)
Numbering of external power supply module terminals
Terminal No.
Destination
54 24 V AC/DC external power supply voltage
55 24 V AC/DC external power supply voltage
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 10 di 18
Annex B
Fig. B1. Mechanical dimensions of electronic unit of the flow sensor
Fig.B2. Sizes and dimensions of the flow sensor
Fig.B2.1. Threaded end connections G3/4“
11 di 18 IFX-M4-01_D_E_2017_04_REV.0
Fig.B2.2. Threaded end connections G1“ Mounting length L=110 mm or L=165 mm Mounting length L=130 mm
a) b) Fig.B2.3. Threaded end connections G1“(a); Flanged end connection DN20 (b)
Mounting length L=190 mm
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 12 di 18
a) Threaded end connections G1 1/4
13 di 18 IFX-M4-01_D_E_2017_04_REV.0
b) Flanged end connection DN25
c) Flanged end connection DN32
Fig.B2.4. Threaded end connections G1 1/4“(a); Flanged end connection DN25 (b);
Flanged end connection DN32 (c); Mounting length L=260 mm
a)
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 14 di 18
b)
c)
Fig.B2.5. Threaded end connections G2“(a); flanged end connection DN40 (b; c) (two design options)
Mounting length L=300 mm
15 di 18 IFX-M4-01_D_E_2017_04_REV.0
a) Dimensions of flow sensors DN50, DN65, DN80, DN100 (Brass housing)
DN65/PN16 DN65/PN25 DN80 DN100
L 300 300 350 350
D 185 185 200 220
H 185 185 200 220
D1 145 145 160 180
B 200 200 215 235
D2 18 18 18 18
n 4 8 8 8
b) Dimensions of flow sensors DN65, DN80, DN100 (Steel housing)
Fig. B2.6. Dimensions of flow sensors DN50, DN65, DN80, and DN100
Annex C Security sealing
Fig.C1. Sealing of the electronic unit of the flow sensor
Electronic general view: the cover is closed, and the cover is opened (1-Manufacturer security seal- adhesive sticker, 2-manufacturer warranty seal- adhesive sticker,
3 –mounting seal)
The m
anufa
cture
r guara
nte
es
only
Englis
h t
ext
availa
ble
on o
ur
web s
ite w
ww
.iso
il.co
m
IFX-M4-01_D_E_2017_04_REV.0 16 di 18
a) Flow sensor G 3/4“ b) Flow sensor G 1“or DN20
1 1 1 1
c) Flow sensor G 1 ¾“; DN25 or DN32 d) Flow sensor G 2“or DN40
1 1 1 1
e) Flow sensor DN50, DN65, DN80, DN100 f) Flow sensor DN65, DN80, DN100 (Brass housing) (Steel housing)
Fig.C2. Sealing of the measuring section of the flow sensor (a;b;c;d;e - 1- manufacturer’s adhesive seal-sticker on the bolts of the cover; f – manufacturer’s hanging seal)
1 1 1 1
17 di 18 IFX-M4-01_D_E_2017_04_REV.0
ISOIL INDUSTRIA S.p.A. HEAD OFFICE SERVICE
Via Fratelli Gracchi, 27 20092 Cinisello Balsamo (MI)
Tel +39 02 66027.1 Fax 039 026123202
If you want to find the complete list of our distributors access at the following link:
http://isoil.com/u_vendita.asp
BEFORE returning any material, please contact our SERVICE at the e-mail address:
Due to the constant technical development of its products, the manufacturer reserves the right to make changes and/or modify the information contained in