22
Electric Motors IE3 Motors hoyermotors.com IE3 Motors

IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

Electric Motors

IE3 Motors

hoyermotors.com

IE3 Motors

Page 2: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

2

Behind Hoyer Motors

Hoyer Motors is an international supplier of high-end

electric motors. Headquartered in Denmark and

China, we are represented through sales offices and

distributors worldwide. We pride ourselves of being an

elite manufacturing enterprise with the highest attention

to service and flexibility – a company where dedication,

competitiveness and reliability are second to none.

We have selected focus on the markets Marine, Industry,

HVAC, Industrial Pumps, Oil & Gas, Wind and HPU. Through

strong partnerships with market leading industrial OEM’s

within these segments, we are able to offer a unique setup

and industrial insight. We add value by understanding the

business and markets of our customers.

At Hoyer Motors, meeting agreements is as natural as

breathing air. We believe in trustworthy partnerships

with our customers and always meet our obligations on

deliveries, documentation and product quality. This is what

we mean by Exceeding Expectations.

Page 3: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

3

General information about Hoyer IE3 electric motorsHoyer IE3 electric motors are manufactured according to in-

ternational standards under IEC 60034-30 and are fulfilling

the requirement of the EC Directive 2009/125 (ecodesign for

energy-related products).

Hoyer motors are installed in many different fields all over

the world and has a proven quality, reliability and perfor-

mance.

Technical informationTotally enclosed squirrel cage, TEFC, three phase motors

type HMA3 (aluminum) in size 56 to 132 (size 160 and 180 on

request) and type HMC3 (cast iron) in size 160 to 400 (below

size 160 and bigger than size 400 on request).

Rotor is casted with 100% pure aluminum and shaft is made

of high quality C45 steel.

All cast iron and aluminum motors are provided with SKF

or similar premium quality bearings. All sizes have fixed

bearing in drive-end as standard. Motors size ≤ 180 are with

closed bearings greased for life.

Stator winding is made with double coated copper wire and

phase to phase insulation. The insulation system is Class

F, maximum 105K temperature rise at 40°C ambient tem-

perature.

Class H insulation system can be delivered on request.

All motors are manufactured according to IEC 60034,

IEC60072, EN50347 and tested according to IEC60034-2-1.

Rotor is dynamically balanced with half key to fullfill vibra-

tion level IEC60034-14 grade A.

Sound level within limits of IEC60034-9.

Standard voltages:

400V Y – Hoyer IE3 Motors ≤ 3kW

400V D – Hoyer IE3 Motors > 3kW

Other voltages can be supplied on request.

Hoyer IE3Electric Motors

All Hoyer IE3 motors are with PTC terminal protection. Mo-

tors can be modified with bimetal detector, heating ele-

ments for stand still protection and PT100 for both winding

and bearings on request.

All Hoyer IE3 Motors are as standard IP55, prepared for drain

holes. Higher protection class on request.

All motors are delivered with blind caps in the terminal box.

Motor size ≥100 are supplied with eyebolts for lifting.

Hoyer IE3 motors are painted C3L according to ISO 12944-

5:2018 in color RAL 9005 low gloss.

Page 4: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

4

Hoyer IE3Electric Motors

Energy efficiency and MEPS

Energy efficiency is a main focus area related to CO2 emissions and industrial pollution. Across borders legislation and Min-

imum Energy Performance Standards (MEPS) are put into force to improve the efficiency of electric motors. The European

MEPS is defined in the Ecodesign directive and Hoyer IE3 fulfils these future regulations. In theory a higher motor efficiency

will result in electrical energy savings.

In addition to lower emissions the financial return of investment is also considerable. With a service life of 10-15 years the

energy consumption of an electric motor often accounts for more than 90% of the total cost of ownership.

100

95

90

85

80

75

70

0.75 1.5 3 5.5 11 18.5 30 45 75 110 160 375

IE4

IE3

IE2

IE1

(kW)

(efficiency)

Efficiency curves for IE4, IE3, IE2 and IE1 4 pole 50Hz electric motors

Application information

Hoyer IE3 electric motors are used within a wide variety of

applications. Some of the typical applications are:

• Fans and HVAC

• Hydraulics

• Pumps

• Compressors and cooling

Page 5: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

5

Drive End None drive end

Motor type 2 pole 4,6,8 pole 2 pole 4,6,8 pole

HMA3 80 6204-2Z/C3 6204-2Z/C3

HMA3 90 6205-2Z/C3 6205-2Z/C3

HMA3 100 6206-2Z/C3 6206-2Z/C3

HMA3 112 6306-2Z/C3 6306-2Z/C3

HMA3 132 6308-2Z/C3 6308-2Z/C3

HMA3 160 6309-2Z/C3 6309-2Z/C3

HMC3 160 6309-2Z/C3 6309-2Z/C3

HMC3 180 6311-2Z/C3 6311-2Z/C3

HMC3 200 6312/C3 6312/C3

HMC3 225 6312/C3 6313/C3 6312/C3

HMC3 250 6313/C3 6314/C3 6313/C3

HMC3 280 6314/C3 6317/C3 6314/C3

HMC3 315 6317/C3 6319/C3 NU319 6317/C3 6319/C3

HMC3 355 6319/C3 6322/C3 NU322 6319/C3 6322/C3

Motor type Main Blindcaps Ass. Blindcaps

HMA3 80 2xM20x1,5 /

HMA3 90 2xM20x1,5 /

HMA3 100 2xM20x1,5 1xM20x1,5

HMA3 112 2xM20x1,5 1xM20x1,5

HMA3 132 2xM25x1,5 1xM20x1,5

HMA3 160 2xM40x1,5 2xM20x1,5

HMC3 160 2xM40x1,5 2xM20x1,5

HMC3 180 2xM40x1,5 2xM20x1,5

HMC3 200 2xM50x1,5 2xM20x1,5

HMC3 225 2xM50x1,5 2xM20x1,5

HMC3 250 2xM63x1,5 2xM20x1,5

HMC3 280 2xM63x1,5 2xM20x1,5

HMC3 315 2xM63x1,5 2xM20x1,5

HMC3 355 2xM72x2,0 2xM20x1,5

Bearings Terminal box

Hoyer IE3Electric Motors

Supply by frequency converter

Hoyer IE3 motors are as standard prepared for frequency converter (VFD) duty. By using a Hoyer IE3 motor together with a

premium VFD there can be several benefits including better process control, energy savings and a reduced starting current.

It can further reduce stress on mechanical equipment and the electrical supply network.

Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric

motor with a VFD. Several parameters are to be considered.

• VFD output voltages spike levels

• VFD filters

• VFD switching frequency

• Motor insulation system

• Motor bearings e.g. current insulated bearings

A switching frequency of 2-8 kHz is recommended to ensure the best motor insulation system lifetime.

Hoyer Drives & Controls offers complete motor and VFD solutions including integrated and stand-alone drives.

Page 6: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

6

Year: 2021

Ins.cl.F

www.hoyermotors.com

IE3

3~Motor

DutyCosφ

IP55 660Kg

Type: HMC3 280M-4

D.E.6317

V.∆/Y A.∆/YrpmKWHz

IE3 eff.at: 400/690V

IM:B3 IEC 60034-1

Serial no.:SH

N.D.E. 6314

400/690

480/830

50

60

90

108

1480

1780

153/88

153/88

0.90

0.90

S1

S1

50Hz 3/4:95.8%

IE3 For catalogue

2013-09-23

IH

Hoyer Motors

1/1: 95.4%

40℃

1/2:94.8%

Amb. temp. 30°C 35°C 40°C 45°C 50°C 55°C 60°C

P/PN 1,05 1,02 1,00 0,97 0,93 0,87 0,82

Altitude 1000m 1500m 2000m 2500m 3000m 3500m 4000m

P/PN 1,00 0,98 0,95 0,91 0,87 0,83 0,78

Rating plate

Name plate

Rating tablesRating factors for power output kW at different ambient temperatures and altitudes are found below.

Ambient temperature Altitude

Hoyer IE3Electric Motors

Page 7: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

7

*Important notice: V3 mounting with standard housing only accepted up to frame size 250. Motors frame size 280 and up need special housing and flange.

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

B5 V1 V3 B35 V15 V35

B14 V18 V19 B34 V17 V37

B3 B6 B7 B8 V5 V6

Hoyer IE3Electric Motors

Page 8: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

8

Motor type Power Speed Current at 400V Efficiency (%) Pf Torque IM Weight

kw rpm IN (A) IS/IN

1/1 load

3/4 load

1/2 load

cos φ TN TS/TN TM/TN J(kgm2) kg

Aluminium motors

HMA3 80 1-2 0,75 2910 1,74 8,35 80,7 81,0 78,9 0,77 2,48 2,95 3,30 0,00099 9,50

HMA3 80 2-2 1,10 2910 2,40 8,60 82,7 83,3 81,9 0,80 3,65 3,40 3,60 0,00134 10,5

HMA3 90S-2 1,50 2920 3,10 9,05 84,2 84,7 83,2 0,82 4,90 2,80 3,00 0,00224 15,0

HMA3 90L-2 2,20 2920 4,40 9,10 85,9 86,8 86,2 0,84 7,20 3,25 3,50 0,00278 19,0

HMA3 100L-2 3,00 2910 5,70 9,25 87,1 87,6 86,5 0,87 9,85 3,45 3,60 0,00444 25,0

HMA3 112M-2 4,00 2910 7,15 8,70 88,1 88,5 87,5 0,92 13,2 2,60 3,00 0,00701 34,0

HMA3 132S1-2 5,50 2930 9,85 9,05 89,2 89,1 87,4 0,90 18,0 2,48 2,80 0,01410 49,5

HMA3 132S2-2 7,50 2930 13,6 9,25 90,1 90,2 89,0 0,88 24,4 2,80 3,00 0,01688 55,0

HMA3 160M1-2 11,0 2950 19,4 8,45 91,2 91,3 90,1 0,89 35,5 2,46 3,20 0,05620 99,0

HMA3 160M2-2 15,0 2950 26,0 8,45 91,9 91,9 90,8 0,90 48,5 2,44 3,40 0,06610 108

HMA3 160L-2 18,5 2960 32,0 10,20 92,4 92,4 91,3 0,91 60,0 2,95 3,80 0,08330 118

Cast iron motors

HMC3 160M1-2 11,0 2950 19,4 8,95 91,2 91,3 90,1 0,90 35,5 2,50 3,50 0,05620 123

HMC3 160M2-2 15,0 2950 26,0 9,95 91,9 91,9 90,8 0,91 48,5 2,95 3,90 0,06610 140

HMC3 160L-2 18,5 2960 32,0 10,6 92,4 92,4 91,3 0,91 60,0 3,20 4,30 0,08330 159

HMC3 180M-2 22,0 2960 38,0 10,0 92,7 92,4 90,9 0,90 71,0 4,10 4,10 0,13050 204

HMC3 200L1-2 30,0 2970 51,0 8,55 93,3 93,5 92,1 0,91 96,5 2,90 3,05 0,18260 247

HMC3 200L2-2 37,0 2970 62,5 9,05 93,7 93,7 92,7 0,91 118 3,65 3,65 0,21540 266

HMC3 225M-2 45,0 2970 76,0 8,70 94,0 93,9 92,9 0,91 144 3,25 3,45 0,34250 336

HMC3 250M-2 55,0 2980 94,0 10,8 94,3 93,9 92,6 0,90 176 3,40 3,95 0,46120 408

HMC3 280S-2 75,0 2980 128 7,40 94,7 94,4 93,2 0,90 240 2,40 3,25 0,76090 604

HMC3 280M-2 90,0 2980 146 8,05 95,0 95,1 94,4 0,91 290 2,80 2,75 0,89040 637

HMC3 315S-2 110 2980 180 7,40 95,2 95,1 94,4 0,93 355 2,10 2,80 1,70570 914

HMC3 315M-2 132 2970 216 7,00 95,4 95,6 95,2 0,93 425 2,02 2,70 1,92280 1012

HMC3 315L1-2 160 2970 260 6,50 95,6 95,8 95,5 0,94 515 1,88 2,70 2,10890 1046

HMC3 315L2-2 200 2980 330 8,60 95,8 95,6 94,6 0,92 640 2,08 2,80 2,60510 1147

HMC3 355M-2 250 2980 415 6,70 95,8 96,0 95,5 0,90 800 1,72 2,30 3,58980 1717

HMC3 355L1-2 315 2980 520 6,60 95,8 96,2 96,0 0,91 1000 1,68 2,30 4,20270 1830

Data at 400V 50HzAt 230V 50Hz the current is √3 x current at 400V and at 690V the current is current at 400V / √3. All other data are identical.

IE3 / 2 pole

Page 9: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

9

IE3 / 4 pole

Motor type Power Speed Current at 400V Efficiency (%) Pf Torque IM Weight

kw rpm IN (A) IS/IN

1/1 load

3/4 load

1/2 load

cos φ TN TS/TN TM/TN J(kgm2) kg

Aluminium motors

HMA3 80 2-4 0,75 1440 1,80 6,65 82,5 82,9 81,0 0,73 4,95 2,95 3,30 0,00265 12,0

HMA3 90S-4 1,10 1450 2,48 8,05 84,1 83,9 81,3 0,76 7,25 2,85 3,00 0,00372 17,0

HMA3 90L-4 1,50 1450 3,40 8,20 85,3 85,0 82,5 0,74 9,85 2,85 3,00 0,00486 22,0

HMA3 100L1-4 2,20 1460 4,55 8,15 86,7 86,9 85,3 0,80 14,4 3,00 3,30 0,00934 27,0

HMA3 100L2-4 3,00 1460 6,15 9,05 87,7 87,9 86,4 0,80 19,6 3,50 3,80 0,01153 33,0

HMA3 112M-4 4,00 1460 7,85 9,35 88,6 89,1 88,2 0,83 26,0 3,10 3,30 0,01625 41,0

HMA3 132S-4 5,50 1460 10,8 8,75 89,6 89,9 88,9 0,82 36,0 2,80 3,00 0,03446 53,0

HMA3 132M-4 7,50 1460 14,0 8,80 90,4 91,1 90,8 0,85 49,0 2,90 3,00 0,04368 62,0

HMA3 160M-4 11,0 1480 20,8 8,10 91,4 91,9 89,9 0,82 71,0 2,80 3,40 0,10550 111

HMA3 160L-4 15,0 1470 28,5 8,90 92,1 92,4 91,8 0,83 97,5 3,00 3,40 0,13430 117

Cast iron motors

HMC3 160M-4 11,0 1470 20,8 8,20 91,4 91,9 89,9 0,83 71,5 2,90 3,65 0,10550 131

HMC3 160L-4 15,0 1470 28,5 9,05 92,1 92,4 91,8 0,83 97,0 3,15 3,40 0,13430 151

HMC3 180M-4 18,5 1470 32,5 8,15 92,6 93,2 91,8 0,88 120 2,65 3,45 0,18730 189

HMC3 180L-4 22,0 1470 38,5 8,60 93,0 93,6 92,4 0,88 142 2,80 3,55 0,23410 215

HMC3 200L-4 30,0 1480 53,0 8,20 93,6 93,7 93,0 0,87 194 2,90 3,25 0,40950 290

HMC3 225S-4 37,0 1480 66,0 7,90 93,9 94,2 93,8 0,86 238 3,05 3,30 0,60700 326

HMC3 225M-4 45,0 1480 77,5 7,50 94,2 94,7 93,5 0,88 290 2,60 2,85 0,68980 350

HMC3 250M-4 55,0 1480 96,0 8,50 94,6 94,6 93,9 0,88 355 3,00 3,10 1,01480 486

HMC3 280S-4 75,0 1490 124 7,25 95,0 94,8 93,8 0,88 480 2,28 2,80 1,73680 594

HMC3 280M-4 90,0 1490 150 8,00 95,2 95,5 94,5 0,90 580 2,55 2,80 2,10890 694

HMC3 315S-4 110 1490 186 8,25 95,4 95,4 94,1 0,90 705 2,60 2,70 3,33250 912

HMC3 315M-4 132 1490 220 8,10 95,6 95,7 94,2 0,91 845 2,50 2,80 3,90700 1032

HMC3 315L1-4 160 1490 265 7,80 95,8 96,1 95,2 0,92 1020 2,26 2,70 4,59650 1115

HMC3 315L2-4 200 1490 325 7,25 96,0 96,2 95,4 0,93 1280 2,08 2,50 5,74560 1253

HMC3 355M-4 250 1490 415 6,45 96,0 96,1 95,6 0,90 1600 1,86 2,30 9,40970 1793

HMC3 355L-4 315 1490 530 7,50 96,0 95,9 95,1 0,90 2020 2,30 2,50 10,7819 1853

Data at 400V 50HzAt 230V 50Hz the current is √3 x current at 400V and at 690V the current is current at 400V / √3. All other data are identical.

Page 10: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

10

IE3 / 6 pole

Motor type Power Speed Current at 400V Efficiency (%) Pf Torque IM Weight

kw rpm IN (A) IS/IN

1/1 load

3/4 load

1/2 load

cos φ TN TS/TN TM/TN J(kgm2) kg

Aluminium motors

HMA3 90S-6 0,75 960 2,02 5,70 78,9 78,3 74,6 0,68 7,45 2,28 2,50 0,00481 16,0

HMA3 90L-6 1,10 960 2,85 6,05 81,0 80,3 76,8 0,68 11,0 2,60 3,00 0,00683 21,0

HMA3 100L-6 1,50 960 3,80 5,90 82,5 82,4 79,9 0,69 14,8 2,55 2,80 0,01249 25,0

HMA3 112M-6 2,20 970 5,65 5,95 84,3 84,1 81,7 0,67 21,8 2,24 3,00 0,01701 35,0

HMA3 132S-6 3,00 980 6,85 7,60 85,6 85,0 82,3 0,74 29,5 2,10 2,20 0,03683 45,0

HMA3 132M1-6 4,00 970 8,75 7,60 86,8 86,7 84,8 0,76 39,0 2,14 2,20 0,04843 53,0

HMA3 132M2-6 5,50 970 11,8 8,35 88,0 88,0 86,4 0,76 54,0 2,44 2,46 0,06322 62,0

HMA3 160M-6 7,50 970 14,8 5,85 89,1 90,0 88,1 0,82 73,5 2,02 2,16 0,12460 123

HMA3 160L-6 11,0 970 21,2 6,35 90,3 91,3 91,1 0,82 108 2,12 2,65 0,16080 138

Cast iron motors

HMC3 160M-6 7,50 970 14,8 5,85 89,1 90,0 88,1 0,82 73,5 1,98 2,16 0,12460 154

HMC3 160L-6 11,0 970 21,2 6,10 90,3 91,3 91,1 0,83 108 2,00 2,50 0,16080 170

HMC3 180L-6 15,0 980 29,0 7,75 91,2 91,6 90,8 0,82 146 2,10 2,60 0,28400 203

HMC3 200L1-6 18,5 980 37,0 6,50 91,7 91,7 89,1 0,78 180 2,08 2,60 0,41790 241

HMC3 200L2-6 22,0 980 44,0 6,95 92,2 92,2 89,9 0,79 214 2,04 2,55 0,48220 256

HMC3 225M-6 30,0 990 58,0 6,10 92,9 93,2 92,5 0,81 290 2,04 2,30 0,68240 322

HMC3 250M-6 37,0 980 65,5 6,95 93,3 93,7 92,0 0,87 360 2,34 2,36 1,16200 405

HMC3 280S-6 45,0 990 82,0 6,70 93,7 93,8 91,9 0,84 435 2,24 2,30 1,87950 521

HMC3 280M-6 55,0 990 98,5 6,45 94,1 94,3 92,6 0,86 530 2,04 2,30 2,26400 570

HMC3 315S-6 75,0 990 132 5,80 94,6 94,9 94,4 0,87 725 2,00 2,30 4,24010 941

HMC3 315M-6 90,0 990 156 5,70 94,9 95,5 94,8 0,88 870 1,86 2,20 4,61870 1021

HMC3 315L1-6 110 990 192 6,95 95,1 95,3 93,9 0,87 1060 2,36 2,60 5,90590 1094

HMC3 315L2-6 132 990 226 6,75 95,4 95,9 95,0 0,88 1280 2,20 2,40 7,11730 1216

HMC3 355M1-6 160 990 275 5,50 95,6 95,9 94,7 0,89 1540 2,00 2,20 9,92910 1591

HMC3 355M2-6 200 990 340 6,05 95,8 96,0 94,8 0,89 1940 2,00 2,20 12,2582 1642

HMC3 355L2-6 250 990 420 5,30 95,8 96,0 95,0 0,90 2420 2,00 2,20 15,9356 1744

Data at 400V 50HzAt 230V 50Hz the current is √3 x current at 400V and at 690V the current is current at 400V / √3. All other data are identical.

Page 11: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

11

IE3 / 8 pole

Motor type Power Speed Current at 400V Efficiency (%) Pf Torque IM Weight

kw rpm IN (A) IS/IN

1/1 load

3/4 load

1/2 load

cos φ TN TS/TN TM/TN J(kgm2) kg

Aluminium motors

HMA3 100L1-8 0,75 720 2,28 5,20 75,0 73,7 69,2 0,63 9,95 2,16 3,10 0,01083 37,0

HMA3 100L2-8 1,10 720 3,20 5,30 77,7 75,9 71,3 0,64 14,60 2,18 3,10 0,01345 42,5

HMA3 112M-8 1,50 700 3,85 4,80 79,7 80,2 78,6 0,71 20,40 2,32 2,80 0,01834 49,0

HMA3 132S-8 2,20 720 5,60 6,30 81,9 81,9 80,0 0,69 29,00 2,60 3,30 0,04720 56,0

HMA3 132M-8 3,00 720 7,25 6,60 83,5 83,8 82,2 0,72 39,50 2,85 3,25 0,05323 68,0

Cast iron motors

HMC3 160M1-8 4,00 720 9,60 5,80 84,8 85,3 84,1 0,71 53,0 2,50 2,85 0,08655 123

HMC3 160M2-8 5,50 720 12,4 6,05 86,2 86,9 85,8 0,74 73,0 2,55 2,75 0,10619 130

HMC3 160L-8 7,50 720 16,8 6,50 87,3 87,7 86,6 0,74 99,0 2,65 2,85 0,14356 157

HMC3 180L-8 11,0 730 24,4 6,50 88,6 89,0 87,8 0,73 144 2,55 2,65 0,20694 186

HMC3 200L-8 15,0 730 33,0 6,70 89,6 89,9 88,7 0,74 196 2,60 2,65 0,33733 236

HMC3 225S-8 18,5 730 39,0 6,70 90,1 90,6 90,0 0,76 240 2,08 2,60 0,53046 271

HMC3 225M-8 22,0 730 45,5 6,95 90,6 91,2 90,8 0,77 285 2,18 2,55 0,62124 317

HMC3 250M-8 30,0 730 58,5 5,70 91,3 91,5 90,5 0,81 390 1,98 2,65 0,89910 448

HMC3 280S-8 37,0 740 72,5 5,75 91,8 92,3 91,6 0,80 480 2,16 2,38 1,53696 545

HMC3 280M-8 45,0 740 89,0 6,70 92,2 92,5 91,3 0,79 585 1,90 2,00 1,83686 564

HMC3 315S-8 55,0 740 106 6,80 92,5 92,8 91,8 0,81 715 1,80 2,00 3,44818 902

HMC3 315M-8 75,0 740 142 6,00 93,1 93,2 92,4 0,82 970 1,94 2,26 4,60014 1007

HMC3 315L1-8 90,0 740 170 6,40 93,4 93,6 92,8 0,82 1160 1,80 2,00 5,39379 1060

HMC3 315L2-8 110 740 206 6,40 93,7 93,9 92,9 0,82 1420 1,80 2,00 6,26884 1111

HMC3 355M1-8 132 740 248 6,40 94,0 94,1 93,2 0,82 1700 1,80 2,00 9,17963 1514

HMC3 355M2-8 160 740 300 6,40 94,3 94,6 93,4 0,82 2060 1,80 2,00 10,3313 1641

HMC3 355L-8 200 740 370 6,40 94,6 94,7 93,8 0,83 2550 1,80 2,00 12,5299 1714

Data at 400V 50HzAt 230V 50Hz the current is √3 x current at 400V and at 690V the current is current at 400V / √3. All other data are identical.

Page 12: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

12

Motor type Pole A AA AB AC AD B BB C D DB E EB EG F G GD H HA HB HD K L LB TB TL

Aluminium motors

HMA3 80 All 125 27 160 159 126 100 122 50 19 M6 40 32 16 6 15,5 6 80 12 - 206 10 298 258 100 100

HMA3 90S All 140 35 177 175 132 100 155 56 24 M8 50 40 24 8 20 7 90 13 - 222 10 328 278 100 100

HMA3 90L 2 140 35 177 175 132 125 155 56 24 M8 50 40 24 8 20 7 90 13 - 222 10 362 312 100 100

HMA3 90L 4,6 140 35 177 175 132 125 155 56 24 M8 50 40 24 8 20 7 90 13 - 222 10 362 312 100 100

HMA3 100L All 160 42 205 198 147 140 176 63 28 M10 60 50 28 8 24 7 100 12 135 247 12 406 346 100 100

HMA3 112M 2,6,8 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 145 280 12 390 330 120 120

HMA3 112M 4 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 145 280 12 430 370 120 120

HMA3 132S All 216 50 256 258 187 140 180 89 38 M12 80 70 30 10 33 8 132 16,5 165 319 12 463 383 120 120

HMA3 132M 4,6,8 216 50 256 258 187 178 218 89 38 M12 80 70 30 10 33 8 132 16,5 165 319 12 501 421 120 120

HMA3 160M 2 254 55 302 314 245 210 260 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 619 509 160 150

HMA3 160M 4,6,8 254 55 302 314 245 210 260 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 619 509 160 150

HMA3 160L 2 254 55 302 314 245 254 304 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 663 553 160 150

HMA3 160L 4,6,8 254 55 302 314 245 254 304 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 663 553 160 150

HB

EG

F

G

GD

D

DB

AD

A

K

AB

AA

HD

H

HA

TB

Hoyer Motors

BB

B

TL

AC

L

E C

LB

EB

IE3 / B3

Page 13: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

13

IE3 / B3

Motor type Pole A AA AB AC AD B BB C D DB E EB EG F G GD H HA HB HD K L LB TB TL

Cast iron motors

HMC3 160M All 65 254 314 313 276 210 260 108 42 M16 110 100 36 12 37 8 160 20 221 436 14,5 610 500 218 162

HMC3 160L All 65 254 314 313 276 254 304 108 42 M16 110 100 36 12 37 8 160 20 221 436 14,5 654 544 218 162

HMC3 180M All 70 279 349 354 292 241 311 121 48 M16 110 100 40 14 42,5 9 180 22 237 472 14,5 686 576 218 162

HMC3 180L All 70 279 349 354 292 279 349 121 48 M16 110 100 40 14 42,5 9 180 22 237 472 14,5 724 614 218 162

HMC3 200L All 70 318 388 396 313 305 369 133 55 M20 110 100 50 16 49 10 200 25 264 513 18,5 769 659 260 192

HMC3 225S 4,6,8 75 356 431 445 336 286 369 149 60 M20 140 130 56 18 53 11 225 28 285 561 18,5 823 683 260 192

HMC3 225M 2 75 356 431 445 336 311 393 149 55 M20 110 100 56 16 49 10 225 28 285 561 18,5 818 708 260 192

HMC3 225M 4,6,8 75 356 431 445 336 311 393 149 60 M20 140 130 56 18 53 11 225 28 285 561 18,5 848 708 260 192

HMC3 250M 2 80 406 484 484 374 349 445 168 60 M20 140 130 56 18 53 11 250 30 316 624 24 909 769 305 230

HMC3 250M 4,6,8 80 406 484 484 374 349 445 168 65 M20 140 130 56 18 58 11 250 30 316 624 24 909 769 305 230

HMC3 280S 2 85 457 542 546 403 368 485 190 65 M20 140 130 56 18 58 11 280 35 361 683 24 959 819 305 230

HMC3 280S 4,6,8 85 457 542 546 403 368 485 190 75 M20 140 130 56 20 67,5 12 280 35 361 683 24 979 839 305 230

HMC3 280M 2 85 457 542 546 403 419 536 190 65 M20 140 130 56 18 58 11 280 35 361 683 24 1010 870 305 230

HMC3 280M 4,6,8 85 457 542 546 403 419 536 190 75 M20 140 130 56 20 67,5 12 280 35 361 683 24 1030 890 305 230

HMC3 315S 2 120 508 628 618 546 406 570 216 65 M20 140 130 56 18 58 11 315 45 430 862 28 1193 1053 420 299

HMC3 315S 4,6,8 120 508 628 618 547 406 570 216 80 M20 170 160 56 22 71 14 315 45 430 862 28 1223 1053 420 299

HMC3 315M 2 120 508 628 618 546 457 680 216 65 M20 140 130 56 18 58 11 315 45 430 861 28 1303 1163 420 299

HMC3 315M 4,6,8 120 508 628 618 546 457 680 216 80 M20 170 160 56 22 71 14 315 45 430 861 28 1333 1163 420 299

HMC3 315L 2 120 508 628 618 546 508 680 216 65 M20 140 130 56 18 58 11 315 45 430 861 28 1303 1163 420 299

HMC3 315L 4,6,8 120 508 628 618 546 508 680 216 80 M20 170 160 56 22 71 14 315 45 430 861 28 1333 1163 420 299

HMC3 355M 2 116 610 726 699 664 560 750 254 75 M24 140 130 56 20 67,5 12 355 52 489,5 1019 28 1507 1367 460 330

HMC3 355M 4,6,8 116 610 726 699 664 560 750 254 95 M24 170 160 56 25 86 14 355 52 489,5 1019 28 1537 1367 460 330

HMC3 355L 2 116 610 726 699 664 630 750 254 75 M24 140 130 56 20 67,5 12 355 52 489,5 1019 28 1507 1367 460 330

HMC3 355L 4,6,8 116 610 726 699 664 630 750 254 95 M24 170 160 56 25 86 14 355 52 489,5 1019 28 1537 1367 460 330

HB

EG

F

G

GD

D

DB

AD

A

K

AB

AA

HD

H

HA

TB

Hoyer Motors

BB

B

TL

AC

L

E C

LB

EB

Page 14: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

14

Motor type Pole AC AD L LB HB TL TB D E F G GD EB EG DB M N P S T LA

Aluminium motors

HMA3 80 All 159 126 298 258 - 100 100 19 40 6 15,5 6 32 16 M6 165 130 200 4-Ø12 3,5 10

HMA3 90S All 175 132 328 278 - 100 100 24 50 8 20 7 40 24 M8 165 130 200 4-Ø12 3,5 10

HMA3 90L 2,4,6 175 132 362 312 - 100 100 24 50 8 20 7 40 24 M8 165 130 200 4-Ø12 3,5 10

HMA3 100L All 198 147 406 346 135 100 100 28 60 8 24 7 50 28 M10 215 180 250 4-Ø14,5 4 14

HMA3 112M 2,6,8 219 168 390 330 145 120 120 28 60 8 24 7 50 28 M10 215 180 250 4-Ø14,5 4 14

HMA3 112M 4 219 168 430 370 145 120 120 28 60 8 24 7 50 28 M10 215 180 250 4-Ø14,5 4 14

HMA3 132S All 258 187 463 383 165 120 120 38 80 10 33 8 70 30 M12 265 230 300 4-Ø14,5 4 15

HMA3 132M All 258 187 501 421 165 120 120 38 80 10 33 8 70 30 M12 265 230 300 4-Ø14,5 4 15

HMA3 160M All 314 245 619 509 148 150 160 42 110 12 37 8 100 36 M16 300 250 350 4-Ø18,5 5 15

HMA3 160L All 314 245 663 553 148 150 160 42 110 12 37 8 100 36 M16 300 250 350 4-Ø18,5 5 15

M

EG

HB

S

AD

TB

G

F

GD

D

DB

Hoyer Motors

LA

P

T

L

N

AC

TL

E LB

EB

IE3 / B5

Page 15: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

15

IE3 / B5

Motor type Pole AC AD L LB HB TL TB D E F G GD EB EG DB M N P S T LA

Cast iron motors

HMC3 160M All 313 276 610 500 221 162 218 42 110 12 37 8 100 36 M16 300 250 350 4-Ø18,5 5 14

HMC3 160L All 313 276 654 544 221 162 218 42 110 12 37 8 100 36 M16 300 250 350 4-Ø18,5 5 14

HMC3 180M All 354 292 686 576 237 162 218 48 110 14 42,5 9 100 40 M16 300 250 350 4-Ø18,5 5 15

HMC3 180L All 354 292 724 614 237 162 218 48 110 14 42,5 9 100 40 M16 300 250 350 4-Ø18,5 5 15

HMC3 200L All 396 313 769 659 264 192 260 55 110 16 49 10 100 50 M20 350 300 400 4-Ø18,5 5 17

HMC3 225S 4,6,8 445 336 823 683 285 192 260 60 140 18 53 11 130 56 M20 400 350 450 8-Ø18,5 5 20

HMC3 225M 2 445 336 818 708 285 192 260 55 110 16 49 10 100 56 M20 400 350 450 8-Ø18,5 5 20

HMC3 225M 4,6,8 445 336 848 708 285 192 260 60 140 18 53 11 130 56 M20 400 350 450 8-Ø18,5 5 20

HMC3 250M 2 484 374 909 769 316 230 305 60 140 18 53 11 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 250M 4,6,8 484 374 909 769 316 230 305 65 140 18 58 11 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 280S 2 546 403 959 819 361 230 305 65 140 18 58 11 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 280S 4,6,8 546 403 979 839 361 230 305 75 140 20 67,5 12 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 280M 2 546 403 1010 870 361 230 305 65 140 18 58 11 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 280M 4,6,8 546 403 1030 890 361 230 305 75 140 20 67,5 12 130 56 M20 500 450 550 8-Ø18,5 5 22

HMC3 315S 2 618 546 1193 1053 430 299 420 65 140 18 58 11 130 56 M20 600 550 660 8-Ø24 6 22

HMC3 315S 4,6,8 618 547 1223 1053 430 299 420 80 170 22 71 14 160 56 M20 600 550 660 8-Ø24 6 22

HMC3 315M 2 618 546 1303 1163 430 299 420 65 140 18 58 11 130 56 M20 600 550 660 8-Ø24 6 22

HMC3 315M 4,6,8 618 546 1333 1163 430 299 420 80 170 22 71 14 160 56 M20 600 550 660 8-Ø24 6 22

HMC3 315L 2 618 546 1303 1163 430 299 420 65 140 18 58 11 130 56 M20 600 550 660 8-Ø24 6 22

HMC3 315L 4,6,8 618 546 1333 1163 430 299 420 80 170 22 71 14 160 56 M20 600 550 660 8-Ø24 6 22

HMC3 355M 2 699 664 1507 1367 489,5 330 460 75 140 20 67,5 12 130 56 M24 740 680 800 8-Ø24 6 25

HMC3 355M 4,6,8 699 664 1537 1367 489,5 330 460 95 170 25 86 14 160 56 M24 740 680 800 8-Ø24 6 25

HMC3 355L 2 699 664 1507 1367 489,5 330 460 75 140 20 67,5 12 130 56 M24 740 680 800 8-Ø24 6 25

HMC3 355L 4,6,8 699 664 1537 1367 489,5 330 460 95 170 25 86 14 160 56 M24 740 680 800 8-Ø24 6 25

M

EG

HB

S

AD

TB

G

F

GD

D

DB

Hoyer Motors

LA

P

T

L

N

AC

TL

E LB

EB

Page 16: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

16

IE3 / B14

B14 flange B14 big flange

Motor type Pole AC AD D DB E EB EG F G GD L LB M N P S T M N P S T TB TL

Aluminium motors

HMA3 80 All 159 126 19 M6 40 32 16 6 15,5 6 298 258 100 80 120 4-M6 3 130 110 160 4-M8 3,5 100 100

HMA3 90S All 175 132 24 M8 50 40 24 8 20 7 328 278 115 95 140 4-M8 3 130 110 160 4-M8 3,5 100 100

HMA3 90L 2,4,6 175 132 24 M8 50 40 24 8 20 7 362 312 115 95 140 4-M8 3 130 110 160 4-M8 3,5 100 100

HMA3 100L All 198 147 28 M10 60 50 28 8 24 7 406 346 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 100 100

HMA3 112M 2,6,8 219 168 28 M10 60 50 28 8 24 7 390 330 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 120 120

HMA3 112M 4 219 168 28 M10 60 50 28 8 24 7 430 370 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 120 120

HMA3 132S All 258 187 38 M12 80 70 30 10 33 8 463 383 165 130 200 4-M10 3,5 215 180 250 4-M12 4 120 120

HMA3 132M All 258 187 38 M12 80 70 30 10 33 8 501 421 165 130 200 4-M10 3,5 215 180 250 4-M12 4 120 120

M

HB

TL

LB E

L

N

T

P

EG

EB

AC

F

G

GD

D

DB

S

TB

AD

Hoyer Motors

Page 17: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

17

IE3 / B34

B14 flange B14 big flange

Motor type Pole A AA AB AC AD B BB C D DB E EB EG F G GD H HA HD K L LB M N P S T M N P S T TB TL

Aluminium motors

HMA3 80 All 125 27 160 159 126 100 122 50 19 M6 40 32 16 6 15,5 6 80 12 206 10 298 258 100 80 120 4-M6 3 130 110 160 4-M8 3,5 100 100

HMA3 90S All 140 35 177 175 132 100 155 56 24 M8 50 40 24 8 20 7 90 13 222 10 328 278 115 95 140 4-M8 3 130 110 160 4-M8 3,5 100 100

HMA3 90L 2,4,6 140 35 177 175 132 125 155 56 24 M8 50 40 24 8 20 7 90 13 222 10 362 312 115 95 140 4-M8 3 130 110 160 4-M8 3,5 100 100

HMA3 100L All 160 42 205 198 147 140 176 63 28 M10 60 50 28 8 24 7 100 12 247 12 406 346 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 100 100

HMA3 112M 2,6,8 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 280 12 390 330 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 120 120

HMA3 112M 4 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 280 12 430 370 130 110 160 4-M8 3,5 165 130 200 4-M10 3,5 120 120

HMA3 132S All 216 50 256 258 187 140 180 89 38 M12 80 70 30 10 33 8 132 16,5 319 12 463 383 165 130 200 4-M10 3,5 215 180 250 4-M12 4 120 120

HMA3 132M All 216 50 256 258 187 178 218 89 38 M12 80 70 30 10 33 8 132 16,5 319 12 501 421 165 130 200 4-M10 3,5 215 180 250 4-M12 4 120 120

Page 18: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

18

IE3 / B35

Motor type Pole A AA AB AC AD B BB C D DB E EB EG F G GD H HA HB HD K L LA LB M N P S T TB TL

Aluminium motors

HMA3 80 All 125 27 160 159 126 100 122 50 19 M6 40 32 16 6 15,5 6 80 12 206 10 298 10 258 165 130 200 4-Ø12 3,5 100 100

HMA3 90S All 140 35 177 175 132 100 155 56 24 M8 50 40 24 8 20 7 90 13 222 10 328 10 278 165 130 200 4-Ø12 3,5 100 100

HMA3 90L All 140 35 177 175 132 125 155 56 24 M8 50 40 24 8 20 7 90 13 222 10 362 10 312 165 130 200 4-Ø12 3,5 100 100

HMA3 100L All 160 42 205 198 147 140 176 63 28 M10 60 50 28 8 24 7 100 12 135 247 12 406 14 346 215 180 250 4-Ø14,5 4 100 100

HMA3 112M 2,6,8 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 145 280 12 390 14 330 215 180 250 4-Ø14,5 4 120 120

HMA3 112M 4 190 45 222 219 168 140 180 70 28 M10 60 50 28 8 24 7 112 13 145 280 12 430 14 370 215 180 250 4-Ø14,5 4 120 120

HMA3 132S All 216 50 256 258 187 140 180 89 38 M12 80 70 30 10 33 8 132 16,5 165 319 12 463 15 383 265 230 300 4-Ø14,5 4 120 120

HMA3 132M All 216 50 256 258 187 178 218 89 38 M12 80 70 30 10 33 8 132 16,5 165 319 12 501 15 421 265 230 300 4-Ø14,5 4 120 120

HMA3 160M All 254 55 302 314 245 210 260 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 619 15 509 300 250 350 4-Ø18,5 5 160 150

HMA3 160L All 254 55 302 314 245 254 304 108 42 M16 110 100 36 12 37 8 160 18 148 405 16 663 15 553 300 250 350 4-Ø18,5 5 160 150

HB

EG

M

Hoyer Motors

P

N

T

E C B

AC

L

LB

BB

LA

EB

TL

F

G

GD

D

DB

S

AD

A

K

AB

AA

H

HD

HA

TB

Page 19: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

19

IE3 / B35

Motor type Pole A AA AB AC AD B BB C D DB E EB EG F G GD H HA HB HD K L LA LB M N P S T TB TL

Cast iron motors

HMC3 160M All 254 65 314 313 276 210 260 108 42 M16 110 100 36 12 37 8 160 20 221 436 14,5 610 14 500 300 250 350 4-Ø18,5 5 218 162

HMC3 160L All 254 65 314 313 276 254 304 108 42 M16 110 100 36 12 37 8 160 20 221 436 14,5 654 14 544 300 250 350 4-Ø18,5 5 218 162

HMC3 180M All 279 70 349 354 292 241 311 121 48 M16 110 100 40 14 42,5 9 180 22 237 472 14,5 686 15 576 300 250 350 4-Ø18,5 5 218 162

HMC3 180L All 279 70 349 354 292 279 349 121 48 M16 110 100 40 14 42,5 9 180 22 237 472 14,5 724 15 614 300 250 350 4-Ø18,5 5 218 162

HMC3 200L All 318 70 388 396 313 305 369 133 55 M20 110 100 50 16 49 10 200 25 264 513 18,5 769 17 659 350 300 400 4-Ø18,5 5 260 192

HMC3 225S 4,6,8 356 75 431 445 336 286 369 149 60 M20 140 130 56 18 53 11 225 28 285 561 18,5 823 20 683 400 350 450 8-Ø18,5 5 260 192

HMC3 225M 2 356 75 431 445 336 311 393 149 55 M20 110 100 56 16 49 10 225 28 285 561 18,5 818 20 708 400 350 450 8-Ø18,5 5 260 192

HMC3 225M 4,6,8 356 75 431 445 336 311 393 149 60 M20 140 130 56 18 53 11 225 28 285 561 18,5 848 20 708 400 350 450 8-Ø18,5 5 260 192

HMC3 250M 2 406 80 484 484 374 349 445 168 60 M20 140 130 56 18 53 11 250 30 316 624 24 909 22 769 500 450 550 8-Ø18,5 5 305 230

HMC3 250M 4,6,8 406 80 484 484 374 349 445 168 65 M20 140 130 56 18 58 11 250 30 316 624 24 909 22 769 500 450 550 8-Ø18,5 5 305 230

HMC3 280S 2 457 85 542 546 403 368 485 190 65 M20 140 130 56 18 58 11 280 35 361 683 24 959 22 819 500 450 550 8-Ø18,5 5 305 230

HMC3 280S 4,6,8 457 85 542 546 403 368 485 190 75 M20 140 130 56 20 67,5 12 280 35 361 683 24 979 22 839 500 450 550 8-Ø18,5 5 305 230

HMC3 280M 2 457 85 542 546 403 419 536 190 65 M20 140 130 56 18 58 11 280 35 361 683 24 1010 22 870 500 450 550 8-Ø18,5 5 305 230

HMC3 280M 4,6,8 457 85 542 546 403 419 536 190 75 M20 140 130 56 20 67,5 12 280 35 361 683 24 1030 22 890 500 450 550 8-Ø18,5 5 305 230

HMC3 315S 2 508 120 628 618 546 406 570 216 65 M20 140 130 56 18 58 11 315 45 430 862 28 1193 22 1053600 550 660 8-Ø24 6 420 299

HMC3 315S 4,6,8 508 120 628 618 547 406 570 216 80 M20 170 160 56 22 71 14 315 45 430 862 28 1223 22 1053600 550 660 8-Ø24 6 420 299

HMC3 315M 2 508 120 628 618 546 457 680 216 65 M20 140 130 56 18 58 11 315 45 430 861 28 1303 22 1163600 550 660 8-Ø24 6 420 299

HMC3 315M 4,6,8 508 120 628 618 546 457 680 216 80 M20 170 160 56 22 71 14 315 45 430 861 28 1333 22 1163600 550 660 8-Ø24 6 420 299

HMC3 315L 2 508 120 628 618 546 508 680 216 65 M20 140 130 56 18 58 11 315 45 430 861 28 1303 22 1163600 550 660 8-Ø24 6 420 299

HMC3 315L 4,6,8 508 120 628 618 546 508 680 216 80 M20 170 160 56 22 71 14 315 45 430 861 28 1333 22 1163600 550 660 8-Ø24 6 420 299

HMC3 355M 2 610 116 726 699 664 560 750 254 75 M24 140 130 56 20 67,5 12 355 52 489,5 1019 28 1507 25 1367740 680 800 8-Ø24 6 460 330

HMC3 355M 4,6,8 610 116 726 699 664 560 750 254 95 M24 170 160 56 25 86 14 355 52 489,5 1019 28 1537 25 1367740 680 800 8-Ø24 6 460 330

HMC3 355L 2 610 116 726 699 664 630 750 254 75 M24 140 130 56 20 67,5 12 355 52 489,5 1019 28 1507 25 1367740 680 800 8-Ø24 6 460 330

HMC3 355L 4,6,8 610 116 726 699 664 630 750 254 95 M24 170 160 56 25 86 14 355 52 489,5 1019 28 1537 25 1367740 680 800 8-Ø24 6 460 330

HB

EG

M

Hoyer Motors

P

N

T

E C B

AC

L

LB

BB

LA

EB

TL

F

G

GD

D

DB

S

AD

A

K

AB

AA

H

HD

HA

TB

Page 20: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

20

Drawings

At hoyermotors.com both 2D and 3D drawings of our IE3 programme are available for download.

M

EG

HB

S

AD

TB

G

F

GD

D

DB

Over Hadstenvej 42, DK-8370 HadstenTel : +45 86982111Fax: +45 86981779www.hoyermotors.com

Hoyer Motors BREAK SHARP

JJI

90211

20140925

WEIGHT:

A3

SHEET 1 OF 1SCALE:1:10

DWG NO.

TITLE:

REVISIONDO NOT SCALE DRAWING

kg

DRAWN

MATERIAL:

DATESIGNATURENAME

EDGES

Q.A

MFG

APPV'D

CHK'D

DEBUR AND

B5-drawing catalogue

LA

P

T

L

N

AC

TL

E LB

EB

Website

As well as various drawings you are able to find data sheets, type tests and other relevant documentation and information at hoyermotors.com

Drawings andWebsite

Page 21: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

21

Other HoyerCatalogues

Page 22: IE3 Motors · 2021. 5. 25. · Depending on the customer application Hoyer Motors refers to IEC 60034-17 and IEC TS 60034-25 when operating an electric motor with a VFD. Several parameters

Hoyer Motors, IE3 Motors, May 2021

Important notice. Text and data in this catalogue are not binding and we reserve the right to implement changes without further notice.

Head OfficesDenmark

Over Hadstenvej 42 · DK-8370 HadstenT +45 86 98 21 11 · F +45 86 98 17 79

[email protected]

China19 Jingwu Middle Road · Beilun District

Ningbo 315821 · ZhejiangT +86 21 8036 4698 · F +86 574 2628 1573

[email protected]

Branch OfficesGermany

Landsberger Straße 155 · 80687 MünchenT +49 89 700 88 235 · F +49 89 543 56 333

[email protected]

SwedenLiljeholmsstranden 5 · PO box 44017

SE-100 73 StockholmT +46 8 446 877 13 · F + 46 8 446 877 20

[email protected]

BeneluxVasteland 78 · 3011 BN, Rotterdam

T +31 10 420 35 20 · F +31 10 420 44 [email protected]

hoyermotors.com

Korea302ho · Code square, 3150-1

Daejeo 2-dong · Gangseo-gu · Busan · KoreaT +82 51 944 1268 · F +82 51 996 0252

[email protected]

Japan

Mizunobu Bldg 7F, 1-11-1, Kitasaiwai Nishi-ku Yokohama

T +81 45 670 [email protected]

hoyermotors.com

USA Hoyer Inc · 5826 Cheswood

Houston TX [email protected]