2
One Giant Leap For Damage Control Orthopaedics Quick Connect Ø 6mm Shank UNYCO CANCELLOUS SCREW UNYCO SCREW Reference Line Cortical Thread Cancellous Thread TRAUMA www.orthofix.com MC-1402-PL-E0 B 06/14 0123 Manufactured by: ORTHOFIX Srl Via Delle Nazioni 9 37012 Bussolengo (Verona), Italy Telephone +39 045 6719000 Fax +39 045 6719380 www.galaxyunyco.com @galaxyunyco Your Distributor is: FLEXIBILITY ± 10° polyaxial movement Ideal for Damage Control Orthopaedics in ready-to-use sterile kit Galaxy UNYCO Diaphyseal Tibia Sterile Kit (99-93506) FAST LOCKING Bar snap in and pre-closure by hand; definitive locking in one step STABILITY Clustering of minimum 3 UNYCO screws per clamp EASE OF USE Torque limited insertion for optimal screw application VERSATILITY Same clamp, two configurations for different fracture patterns 2x Large Multiscrew Clamp for UNYCO Screws 1x Rod Ø 12mm L 350mm 8x UNYCO Screw QC Shaft Ø 6mm 4x UNYCO Cancellous Screw QC Shaft Ø 6mm 1x Allen Wrench 5mm 1x Power Drill Torque Limiter 99-93567 Limited Torque Wrench (out of kit, available upon request) 1. Galaxy Unyco “Short Configuration” is composed by 2 Large Multiscrew Clamps for UNYCO Screws in U configuration and 8 UNYCO Screws 2. Galaxy Unyco “Long Configuration” is composed by 2 Large Multiscrew Clamps for UNYCO Screws in U configuration, 4 UNYCO Screws and 2 UNYCO Cancellous Screws 3. Competitor Z-Frame is composed by 4 bicortical screws, 3 connecting bars and 6 single clamps MECHANICAL TESTS AXIAL STIFFNESS (%) UNYCO “Short” Configuration 0 20 40 60 80 100 UNYCO “Long” Configuration Competitor Z-Frame AXIAL PEAK LOAD (%) ML DISPLACEMENT (%) MULTICYCLE AXIAL LOAD (50K CYCLES ±F) % UNYCO “Short” Configuration UNYCO “Short” Configuration UNYCO “Short” Configuration 0 0 0 20 20 20 40 40 40 60 60 60 80 80 80 100 100 100 UNYCO “Long” Configuration UNYCO “Long” Configuration UNYCO “Long” Configuration Competitor Z-Frame Competitor Z-Frame Competitor Z-Frame Failure at 1 cycle BICORTICAL SCREW 1. 2. 3. L Cancellous Screw Cancellous Screw L L Internal tests on bone analog show that Galaxy UNYCO has great mechanical performance. When tested, these two frame configurations showed the minimum and maximum value of mechanical performance. All other possible frame configurations with Galaxy UNYCO Diaphyseal Tibia Sterile Kit gave results within this range of values.

Ideal for Damage Control Orthopaedics · For Damage Control Orthopaedics Quick Connect Ø 6mm Shank UNYCO CaNCellOUs sCrew UNYCO sCrew Reference Line Cortical Thread Cancellous Thread

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ideal for Damage Control Orthopaedics · For Damage Control Orthopaedics Quick Connect Ø 6mm Shank UNYCO CaNCellOUs sCrew UNYCO sCrew Reference Line Cortical Thread Cancellous Thread

One Giant Leap For Damage Control Orthopaedics

Quick Connect

Ø 6mm Shank

UNYCO CaNCellOUs sCrew

UNYCO sCrew

Reference Line

Cortical Thread

Cancellous Thread

TRAUMA

www.or thof i x . comMC-1402-PL-E0 B 06/14 0123

Manufactured by: ORTHOFIX SrlVia Delle Nazioni 937012 Bussolengo (Verona), ItalyTelephone +39 045 6719000Fax +39 045 6719380

www.galaxyunyco.com

@galaxyunycoYour Distributor is:

FLEXIBILITY± 10° polyaxial

movement

Ideal for Damage Control Orthopaedics in ready-to-use sterile kit

Galaxy UNYCO Diaphyseal Tibia Sterile Kit (99-93506)

FAST LOCKING Bar snap in

and pre-closure by hand; definitive locking

in one step

STABILITYClustering of

minimum 3 UNYCO screws per clamp

EASE OF USETorque limited

insertion for optimal screw application

VERSATILITYSame clamp, two configurations for different fracture

patterns

2x Large Multiscrew Clamp for UNYCO Screws1x Rod Ø 12mm L 350mm8x UNYCO Screw QC Shaft Ø 6mm4x UNYCO Cancellous Screw QC Shaft Ø 6mm1x Allen Wrench 5mm1x Power Drill Torque Limiter

99-93567 Limited Torque Wrench (out of kit, available upon request)

1. Galaxy Unyco “Short Configuration” is composed by 2 Large Multiscrew Clamps for UNYCO Screws in U configuration and 8 UNYCO Screws

2. Galaxy Unyco “Long Configuration” is composed by 2 Large Multiscrew Clamps for UNYCO Screws in U configuration, 4 UNYCO Screws and 2 UNYCO Cancellous Screws

3. Competitor Z-Frame is composed by 4 bicortical screws, 3 connecting bars and 6 single clamps

meChaniCal TesTs

aXIal sTIFFNess (%)

UNYCO “Short” Configuration

0

20

40

60

80

100

UNYCO “Long” Configuration

Competitor Z-Frame

aXIal PeaK lOaD (%)

Ml DIsPlaCeMeNT (%)MUlTICYCle aXIal lOaD (50K CYCles ±F) %

UNYCO “Short” Configuration

UNYCO “Short” Configuration

UNYCO “Short” Configuration

0

00

20

2020

40

4040

60

6060

80

8080

100

100100

UNYCO “Long” Configuration

UNYCO “Long” Configuration

UNYCO “Long” Configuration

Competitor Z-Frame

Competitor Z-FrameCompetitor Z-Frame

Failure at 1 cycle

FIXATION

BICOrTICal sCrew

1.

2.

3.

L

Cancellous Screw

Cancellous ScrewL

L

Internal tests on bone analog show that Galaxy UNYCO has great mechanical performance. When tested, these two frame configurations showed the minimum and maximum value of mechanical performance. All other possible frame configurations with Galaxy UNYCO Diaphyseal Tibia Sterile Kit gave results within this range of values.

Page 2: Ideal for Damage Control Orthopaedics · For Damage Control Orthopaedics Quick Connect Ø 6mm Shank UNYCO CaNCellOUs sCrew UNYCO sCrew Reference Line Cortical Thread Cancellous Thread

FIXATION

Compatible with Galaxy Fixation System for spanning knee and ankle

Reduced exposure to X-rays

Designed to avoid contamination of the medullary canal

Minimal invasiveness

The system is MRI Conditional at 1.5 and 3 Tesla(refer to PQ mCs)

UNYCO Cancellous Screw

UNYCO Screw

XCaliber Screw

XCaliber Screw

Conceived foreasier conversion from temporary to definitive fixation

Modularity