Page 2: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Multi-step process

Design compartmentation (egress) system

Calculate occupancy Calculate width of stair Calculate rise and run of stair Lay out stair on all levels Lay out adjacent spaces (areas of

refuge, lobbies)

Page 3: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Means of Egress:

A continuous and unobstructed path of

travel from any point in a building to it’s

exterior or public way.

Page 4: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Step 1

Page 5: ID 234 Building Codes Fall 2012 Vertical Components of Egress

multi-story egress diagram

Page 6: ID 234 Building Codes Fall 2012 Vertical Components of Egress

…with a lobby

Page 7: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Defend in place: no sprinklers

Page 8: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Areas of Refuge

Page 9: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Step 2

Page 10: ID 234 Building Codes Fall 2012 Vertical Components of Egress
Page 11: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Half Diagonal Rule(1/3 with sprinklers)

Page 12: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Practice problem:

1-4 Offices 5 Cafe

Page 13: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Practice problem:

14’-0” Floor to floor height Fully sprinklered How many exits required? What is minimum separation of exits? What is dimension of the stairs

Page 14: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Step 3

Page 15: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Area Allowance per occupant

Page 16: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Sample calculation

Page 17: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Number of Exits

Page 18: ID 234 Building Codes Fall 2012 Vertical Components of Egress
Page 19: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Step 4

Page 20: ID 234 Building Codes Fall 2012 Vertical Components of Egress

780 CMR Section 10

Page 21: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Step 5

Page 22: ID 234 Building Codes Fall 2012 Vertical Components of Egress

dimensional requirements

Minimum width 44” (non-residential) Rise = 7” maximum Run = 11” minimum Cannot narrow from top to bottom Landings every 12’-0” vertical

(maximum) Guard rails when drop >27” Handrails both sides Handrail extensions

Page 23: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Stair dimensions

Page 24: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Overall stair dimensions

Page 25: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Guard rails

Page 26: ID 234 Building Codes Fall 2012 Vertical Components of Egress

Guard rails

Page 27: ID 234 Building Codes Fall 2012 Vertical Components of Egress

in our practice problem…

What is riser dimension? What is the length of the stair? What is the dimension of the stairwell?

Page 28: ID 234 Building Codes Fall 2012 Vertical Components of Egress

other constraints still apply Door push and pull clearance Panic bars required Minimum head height = 80” Protruding objects: 4” maximum Threshold dimensions Door closers required Maximum area of glass in door: 144 sq.

in. No windows allowed Minimum light level: 11 lux (1

footcandle)