IBM System Storage
EXN4000 Storage Expansion UnitInstallation and Setup Instructions
GC27-2079-02
���
IBM System Storage
EXN4000 Storage Expansion UnitInstallation and Setup Instructions
GC27-2079-02
���
Notices
Mail comments to:IBM CorporationAttention Department GZW9000 South Rita RoadTucson, AZ 85744-0001
www.ibm.com/storage/support/nseries/
References in this publication to IBM products or services do not imply that IBM intends to make them available inevery country or region.
IBM, the IBM logo, and ibm.com® are trademarks or registered trademarks of International Business MachinesCorporation in the United States, other countries, or both. A complete and current list of other IBM trademarks isavailable on the web at www.ibm.com/legal/copytrade.shtml.
Data ONTAP, NetApp, and Network Appliance are trademarks and/or registered trademarks of NetApp, Inc in theUnited States and other countries.
Other company, product, and service names may be trademarks or service marks of others.
© Copyright IBM Corporation 2012.US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contractwith IBM Corp.
Contents
Before you begin . . . . . . . . . . . vOverview of the EXN4000 storage expansion unit. . vi
Installation and setup instructions . . . 1Unpacking the EXN4000 . . . . . . . . . . 1Installing the rails in an IBM 19-inch rack . . . . 1Installing the EXN4000 in the rack . . . . . . . 3
Setting the speed switch . . . . . . . . . . 4Grounding expansion units . . . . . . . . . 5Installing the power cables . . . . . . . . . 6Connecting power to the EXN4000 . . . . . . . 6Setting the storage expansion unit shelf IDs . . . . 7Cabling the EXN4000 . . . . . . . . . . . 8Booting the system . . . . . . . . . . . . 8
© Copyright IBM Corp. 2012 iii
iv
Before you begin
This document provides installation and setup instructions for the IBM® SystemStorage® EXN4000 storage expansion unit, sometimes referred to as a shelf in thisand other documents.
Additional information about the EXN4000, including a comparison of theEXN4000 with other N series storage expansion units, can be found in the IBMSystem Storage EXN4000 Storage Expansion Unit Hardware and Service Guide.
For additional information about the EXN4000 and related topics, refer to thefollowing resources:v IBM System Storage N series Introduction and Planning Guide
v IBM Environmental Notices and User Guide
v IBM System Storage N series support website at www.ibm.com/storage/support/nseries/
Read the safety notices
Before continuing, make sure that you have reviewed the safety notices in thedocumentation that came with this system. Do not plug any cables into the system,adapters, or any electrical outlets until you have reviewed the safety informationand followed the procedures in this document.
Need help?
If you encounter any difficulties while setting up your system, contact IBM serviceand support for assistance. More information can also be found on the IBM SystemStorage N series support website:
www.ibm.com/storage/support/nseries/
About the IBM N series support website
The IBM System Storage N series support website requires users to register inorder to obtain access to N series support content on the web. To understand howthe N series support web content is organized and navigated, and to access the Nseries support website, go to the following publicly accessible web page:
www.ibm.com/storage/support/nseries/
This web page also provides links to AutoSupport information as well as otherimportant N series product resources.
Software requirements
Verify that your storage system meets the following software requirements:v N3220 and N3240 Data ONTAP 8.1RC2 or later.v For Data ONTAP 7.x releases, the minimum software requirement to support the
EXN4000 is Data ONTAP 7.3.3P2 or later, except for N3400 and N3600 systems,which require Data ONTAP 7.3.4 or later.
© Copyright IBM Corp. 2012 v
v For Data ONTAP 8.x 7-Mode releases, the minimum software requirement tosupport the EXN4000 is Data ONTAP 8.0P1 or later, except for N3400 and N3600systems, which require Data ONTAP 8.0.1 or later.
Customer-supplied items for installationv Console (for example, a PC or laptop) with a serial portv #2 Phillips screwdriverv Flat-bladed screwdriverv 7-mm nut driver (for setting ID switches)v Antistatic electrostatic discharge (ESD) wrist strap and grounding leash
Hot-adding EXN4000s
You can hot-add an EXN4000 to any supported storage system. For hot-addinginstructions, see the IBM System Storage N series EXN4000 Hardware and ServiceGuide.
Overview of the EXN4000 storage expansion unitRefer to the following figures to familiarize yourself with the EXN4000 storageexpansion unit.
45678910111213 3 2 1 0
Drive Bays
Shelf 1
013
Loop ID29 - 16
Figure 1. Shelf ID label
Power
FaultLoop ALoop BSystem
Disk shelf ID display
Figure 2. EXN4000 front panel LEDs
vi
Installation and setup instructions
Use these instructions to install and set up your EXN4000 storage expansion unit.
Unpacking the EXN4000Use these instructions to unpack the EXN4000.
About this task
Important: If your system was shipped already assembled and cabled in a rack, godirectly to the Installation and Setup Instructions for your N series storage system.
Note: The contents of the box might differ based on the model you purchased.
Procedure1. Verify that the EXN4000 (2863-004) shipping packages include the following
items:v 1 EXN4000 storage expansion unitv 1 Enclosure shelf IDs labelv Small Form Factor Pluggable (SFP) module (optional)v 1 IBM rail kitv 1 electrostatic discharge (ESD) wrist strapv 1 set of publicationsv 2 power cordsv Miscellaneous data cables, as ordered
CAUTION:Use safe practices when lifting.
svc00168
32-55 kg (70.5-121.2 lbs)
CAUTION:The weight of this part or unit is between 32 and 55 kg (70.5 and 121.2lb). It takes three persons to safely lift this part or unit. (C010) Tomake the unit lighter and easier to move, remove the power suppliesand Input/Output modules (IOMs), noting the location of eachcomponent for reinstallation. Do not remove the disk drives or driveblank covers to reduce the weight. After the unit is installed in therack, reinsert the power supplies and IOMs.
2. Remove the expansion unit and its tray using the handles built into thecardboard tray. Place the expansion unit and tray on a table.
3. Remove the top portion of the plastic surrounding the expansion unit.
Installing the rails in an IBM 19-inch rackUse these instructions to install the rails on which you will mount the EXN4000.
About this task
Note: Read this document in its entirety before proceeding.
© Copyright IBM Corp. 2012 1
Procedure1. Loosen (but do not remove) the four rail adjustment screws on each rail, as
shown in Figure 3.
2. Refer to Figure 4 on page 3. At the front of the rack, position the right-hand railin the rack at the appropriate EIA location. Make sure that the two locatingpins seat properly. The bottom of the rail should line up with the bottom EIAboundary.
Note: When installed, each EXN4000 will occupy a 3U space.
Right rail
Left rail
Front of rack
Rear of rack
Rail adjustmentscrews
Locating pins
exn40002
Figure 3. Installing the rails in the rack
2
Using two silver pan head M5 screws, attach the rail to the front of the rackusing holes H3 and H7. Tighten these screws with a screwdriver.
3. At the rear of the rack, position the rail at the same EIA location used in step 2.Make sure that the locating pins seat properly. Using two silver pan head M5screws, attach the rail to the rack using holes H2 and H8. Tighten these screwswith a screwdriver.
4. Tighten the four rail adjustment screws on the installed rail.5. Repeat steps 2 through 4 for the left-hand rail.6. Repeat steps 1 through 5 for each additional EXN4000 that you are installing in
the rack, making sure to allow 3U of space for each EXN4000.
Installing the EXN4000 in the rackUse these instructions to install the EXN4000 in the rack.
Before you begin
18-32 kg (39.7-70.5 lbs)
svc00167
CAUTION:A fully populated EXN4000 weighs is less than 32 kg (70.5 lbs). Usetwo people to lift an EXN4000 into a rack. To make the unit lighterand easier to move, remove the power supplies and Input/Outputmodules (IOMs), noting the location of each component forreinstallation. Do not remove the disk drives or drive blank covers toreduce the weight. After the unit is installed in the rack, reinsert thepower supplies and IOMs.
Note: Verify the shelf IDs before installing into the rack. All shelf IDs should becorrect and sequential in the individual loop(s). If the filer and expansion unitwere configured together by manufacturing, these IDs are already set. The label onthe front should match the switch on the back. For more information, refer to theEXN4000 Hardware and Service Guide.
Section of rack EIA rail
H2
H1
H3
H4
H5
H6
H7
H8
H9
Locating pins
Bottom rail screws
REARLeft and Right
Rails
Chassis attach screws
H2
H1
H3
H4
H5
H6
H7
H8
H9
FRONTLeft and Right
Rails
Top rail screws
Locating pins
Chassis attach screws 1 EIA unit (1U)
Bottom rail screws
Top rail screws
exn
40
00
3
Figure 4. Section of rack EIA rail
Installation and setup instructions 3
Procedure1. Ground yourself to the EXN4000 using the grounding leash that came with the
system.2. From the front of the rack, place the expansion unit onto the rails and slide it
in until the front mounting bracket of the expansion unit is flush with theframe rails of the rack.
3. At the front of the rack, using four black hex head M5 screws in the H2 and H8holes, secure the system unit to the rack by threading the screws through thesystem unit bracket and the rack frame rail into the threaded rail nuts. Tightenthe screws using the 7-mm nut driver.
4. From the rear of the rack, use two silver pan head M5 screws to attach the rearof the chassis to the rails, as shown in Figure 5.
Setting the speed switchMake sure that all expansion unit speed switches are set to the correct position foryour application.
If you are connecting to an N3700 storage system, the speed switch must be set tothe 1Gb position. If you are connecting to any other N series storage system, thespeed switch must be set to the 2Gb or 4Gb position, as required by the storagesystem.
Note: If you have both EXN2000s and EXN4000s in a single expansion unit loop,the speed setting for all EXN units must be set to the same speed (1Gb ifconnecting to an N3700, or 2Gb if connecting to any other N series system).
For information about 4Gb support for your filer model, see the or for your Nseries filer.
Use the following diagram for reference:
1
exn40004
Figure 5. Attaching the rear of the chassis
4
Header Header
�1� Shelf ID - close-up view
�2� Mute button
�3� Shelf ID
�4� In port activity LED
�5� Out port activity LED
�6� In port
�7� Out port
�8� Fault LED
�9� Gb switch (set to 2Gb)
Grounding expansion unitsIf only one expansion unit is being used, go to Step 6, "Installing the powercables".
If two or more expansion units are being used continue with the following.
Using the grounding kit, fasten the lug at one end of the 0.25m grounding cable toone of the two threaded inserts (adjacent to the power supply receptacles asindicated by a ground symbol) at the back of the expansion unit using the M5 x0.5-inch screw.
If additional expansion units need to be grounded, continue attaching thegrounding cables from unit to unit, overlaying the hole on one end of thegrounding cable from one to the next.
2
1Gb 2Gb
2
4Gb
2Gb4Gb 1Gb ELP
2
3
4
5
6
7 8
9
1
exn40005
Figure 6. Setting the speed switch
Installation and setup instructions 5
Header Header
�1� Dual expansion unit grounding
�2� Multiple expansion unit grounding
�3� Grounding cable
�4� Grounding cables
Installing the power cablesMake sure all power supply switches of the expansion unit(s) are in the Offposition.
Connect the power cords to all PSU1 and PSU2 power receptacles for all expansionunits that are being installed by holding the wire clamp up, plugging in the powercord, and lowering the clamp to secure the power cord.
Connect the power cords to the power sources, making sure that the powersupplies on the left side of the system are connected to a separate AC source thanthe power supplies on the right side of the system. This ensures redundant power.
Attention: Do not power on the system at this time.
Connecting power to the EXN4000Use these instructions to connect power to the EXN4000.
Procedure1. Make sure all power supply switches on the storage expansion unit (or units)
are in the Off position.2. Connect the power cords to each EXN4000 storage expansion unit and secure
each power cord in place with the power cord retainer. Make sure that the
2
3
4
1
exn40006
Figure 7. Grounding expansion units
6
power supply on the left side of the system is connected to a separate ACsource than the power supply on the right side of the system. This ensuresredundant power.
Note: You do not need to ground EXN4000s; grounding is done through thepower cords.
3. Turn on power to the EXN4000 storage expansion units and wait for the diskdrives to spin up.
Setting the storage expansion unit shelf IDsA unique shelf ID is required for each storage expansion unit within the entirestorage system.
About this task
A valid EXN4000 storage expansion unit shelf ID is 0 - 7.
If your storage system has SAS and FC storage expansion units, the storageexpansion unit shelf IDs do not need to be unique between the SAS and FCexpansion units. (FC expansion unit shelf IDs continue to be unique within eachFC loop. SAS expansion unit shelf IDs continue to be unique to all other SASexpansion units in the storage system, including the N3220 or N3240 system'sinternal SAS shelf ID.)
Visually verify that the shelf ID for each storage expansion unit is unique. If not,set the shelf ID as follows. For additional details, see the IBM System StorageEXN4000 Storage Expansion Unit Hardware and Service Guide.
Procedure1. Remove the front bezel if you have not already removed it.2. Press and hold the storage expansion unit shelf ID button �1� until the first
digit blinks.
3. Press the button until the correct number is displayed.4. Repeat steps 2 and 3 for the second digit.5. Press and hold the button until the second number stops blinking.
Both numbers start blinking and the operator display panel fault LEDilluminates in about five seconds.
6. Power-cycle the EXN4000 to make the new expansion unit shelf ID take effect.7. Replace the front bezel.
1 exn
35
00
06
Figure 8. Shelf ID button
Installation and setup instructions 7
Cabling the EXN4000Use these instructions to cable the EXN4000.
About this task
Cable the first expansion unit (for example, ID=x=1) controller A Output portmodule to the second expansion unit ( ID=x+1=2) controller A module Input port.Repeat as necessary to attach a third expansion unit ( ID=x+2=3) to the secondexpansion unit.
For dual node connection, cable the expansion unit controller B Output portmodule to the expansion unit controller B module Input port. Repeat as needed.
Make sure that the cables are secure.
Note:
1. To cable your expansion unit to an N series storage system, refer to theInstallation and Setup Instructions for the N series storage system to which youare connecting the EXN4000.
2. For information about dual-path Fibre Channel cabling, refer to the Installationand Setup Instructions for the N series storage system to which you areconnecting the EXN4000.
Booting the systemSee the Installation and Setup Instructions that came with your N series storagesystem for instructions on booting your storage system for the first time.
About this task
See the Data ONTAP Software Setup Guide for the setup worksheet and other setupinformation.
Out In
OutInB
A
Out In
OutInB
A
Out In
OutInB
A
2
3
4
1
exn40007
Figure 9. Cabling the EXN4000
8
����
Part Number: 00V7380
Printed in USA
GC27-2079-02
(1P)
P/N:
00V7
380