Export department: Tel: +48 68 45 75 139/ 276/ 305/ 386 Fax: +48 68 32 54 091 e-mail: [email protected] LUMEL S.A. ul. Słubicka 1 65-127 Zielona Góra POLAND WWW.LUMEL.COM.PL SM3 module of logic or counter inputs GALVANIC ISOLATION: INPUTS: OUTPUTS: FEATURES: Adjoined informaon about consumpon of medium (water, gas heat, electrical energy) to monitoring systems and PLC • Conversion of logic states or impulses into RS-485 Modbus Two programmable logic or counter inputs Auxiliary counters with reset possibility Counter state stored in the non-volale memory. MOD BUS RS 485 E�ample of application 8 x binary output SCADA Program LPConfig RS 485 Supply RS 232 RS 485 E�ternal features Overall dimensions 22.5 x 120 x 100 mm Weight < 0.3 kg Protecon grade IP40 from terminal side: IP20 Digital interface Interface type Transmission protocol Modes Baud rate RS-485 Modbus RTU 8N2,8E1,8O1,8N1 2400; 4800; 9600; 19.2 k; 38.4 k bit/s Modbus ASCII 8N1, 7E1, 7O1 Inputs Input type Range Logic 0 logic 0…2.4 V 1 logic 3.4…24 V Counter 0..4 294 967 295 impulses; min. impulse me: 0.5 ms Outputs Output type Properes Remarks Digital interface RS-485 Modbus ASCII/RTU HMI Controlin BV -+31 (0)180 33 05 22 - [email protected] - www.controlin.nl

I HMI SCADA · 2019-07-31 · •Auxiliary counters with reset possibility •Counter state stored in the non-volati le memory. MOD BUS RS 485 E ample of application 8 x binary output

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Export department:Tel: +48 68 45 75 139/

276/ 305/ 386Fax: +48 68 32 54 091e-mail: [email protected]

LUMEL S.A.ul. Słubicka 165-127 Zielona GóraPOLANDWWW.LUMEL.COM.PL

SM3 module of logic or counter inputs

GAlVANIC ISolATIoN:

INPUTS:

oUTPUTS:

FeATUReS:• Adjoined informati on about consumpti on of medium (water, gas

heat, electrical energy) to monitoring systems and PLC

• Conversion of logic states or impulses into RS-485 Modbus

• Two programmable logic or counter inputs

• Auxiliary counters with reset possibility

• Counter state stored in the non-volati le memory.

MODBUS

RS485

E�ample of application

8 x binary output

SCADA

ProgramLPConfig

RS485Supply

RS232

RS485

E�ternal features Overall dimensions 22.5 x 120 x 100 mmWeight < 0.3 kg Protecti on grade IP40 from terminal side: IP20

Digital interfaceInterface type Transmission protocol Modes Baud rate

RS-485Modbus RTU 8N2,8E1,8O1,8N1 2400; 4800; 9600; 19.2 k;

38.4 k bit/sModbus ASCII 8N1, 7E1, 7O1

InputsInput type Range

Logic 0 logic 0…2.4 V1 logic 3.4…24 V

Counter 0..4 294 967 295 impulses; min. impulse ti me: 0.5 ms

OutputsOutput type Properti es Remarks

Digital interface RS-485 Modbus ASCII/RTU

HMI

Controlin BV - +31 (0)180 33 05 22 - [email protected] - www.controlin.nl

See AlSo:

Export department:Tel: +48 68 45 75 139/

276/ 305/ 386Fax: +48 68 32 54 091e-mail: [email protected]

LUMEL S.A.ul. Słubicka 165-127 Zielona GóraPOLANDWWW.LUMEL.COM.PL

Connection diagrams

SM3 module of logic or counter inputs

For more information about LUMEL's

products please visit our website:

www.lumel.com.pl

OUR OFFER

www.lumel.com.pl

SM3-19.C

Panel operatorski serii HMI.

SMC - Programmable

controller

Free LPConfig software

A B GND

8

5

98

123

9 1

5

6

9DB9

1

5

6

9DB9

BA

GND

GND

RxD

TxD

B

A

RS-485

PORT RS-485

PORT RS-232

Module SM3

PD51converter

PC computer with RS-485 card

PC computer

1

5

6

9

DB91

6

GND

RxDTxD

PC computer

RS-232 socketSM3 module

SM3

RxD

TxD

RS-485A

B

6

1

GND GND5 V

7

2

8

3

9

4 5

85... 253 V20... 50 V

RS-232

Supply

Input1 Input2

Connection way of external signals

Connection way of the RS-232 interface

Rated operating conditions

Supply voltage 85...253 V a.c./d.c. (40...400 Hz) or d.c.20...50 V a.c./d.c. (40...400 Hz) or d.c.

Input power: ≤ 4 VA

Temperature ambient: -10...23...55°CRelative humidity < 95%Operating position on a TS35 railExternal magnetic field < 400 A/m

Safety and compability requirementsElectromagnetic compatibility

Noise immunity acc. to EN 61000-6-2 Noise emissions acc. to EN 61000-6-4

Isolation between circuits acc. to EN 61010-1Pollution level 2Installation category III

Maximum phase-to-earth operating voltage Supply: 300 V, input 50 V,Output: 50 V

Altitude a.s.l. 2000 m

OrderingModule of systems SM3 X XX XSupply:

85...253 V a.c./d.c. 1

20...50 V a.c./d.c. 2

Version:standard 00

Acceptance tests:without additional quality inspection requirements 8with an extra qualityinspection certificate 7acc. to customers requests* X

Ordering example:

The code SM3 - 1 00 7 means:

SM3 - module of SM3 type 1 - supply voltage 85...253 V a.c./d.c. 00 - standard version 7 - with an extra quality inspection certificate

1

5 V

2 3 4 5

RS-232

Input 1 Input 2

Electrical connection of external circuitsConnection way of the RS-485 interface

Electrical connection of the logic input module Connection way

of the logic inputs

* after agreeing with the manufacturer