Upload
hoanglien
View
229
Download
2
Embed Size (px)
Citation preview
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
1
7-04
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
INSULATION:
Solid, high-density polyethylene or polypro-
pylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and crosstalk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are as-
sembled to form the final core. The core is
filled with ETPR (80°C) compound. Then
covered with a non-hygroscopic tape with
an overlap. A filling compound is applied
over the wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and superunits are divided into 12 and 13
pair sub-units.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the shield.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Meets REA/RUS PE-39
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated,
Copper Conductor.
Telecordia (Bellcore) equivalent: none
Outside plant telephony or underground installation.
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
ISO-9001 Quality Assurance System
Filled Solid ALPETH Cable
I. Exchange Cables
62.39.01
PE-39REA/RUS
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
19 AWG
626205
626206
626207
626208
626209
626210
626211
626213
626214
6
12
18
25
50
75
100
200
300
0.71
0.85
0.96
1.06
1.42
1.66
1.83
2.48
2.95
18.0
21.5
24.5
27.0
36.0
42.0
46.5
63.0
75.0
211
349
466
590
1059
1485
1921
3557
5197
315
520
695
880
1580
2215
2865
5305
7750
5000
5000
5000
5000
3000
3000
3000
1000
650
1525
1525
1525
1525
915
915
915
305
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
22 AWG
626188
626189
626190
626191
626192
626193
626194
626196
626197
626198
626199
6
12
18
25
50
75
100
200
300
400
600
0.57
0.67
0.75
0.85
1.04
1.22
1.38
1.75
2.13
2.40
2.87
14.5
17.0
19.0
21.5
26.5
31.0
35.0
44.5
54.0
61.0
73.0
134
201
228
342
563
798
1019
1797
2625
3997
4976
200
300
340
510
840
1190
1520
2680
3915
5960
7420
5000
5000
5000
5000
3000
3000
3000
1650
1650
1000
1000
1525
1525
1525
1525
1525
915
915
500
500
305
305
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
24 AWG
626168
626169
626170
626171
626172
626173
626174
626196
626177
626178
626179
626180
626181
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.47
0.59
0.67
0.75
0.89
1.04
1.16
1.48
1.71
1.95
2.35
2.81
3.23
12.0
15.0
17.0
19.0
22.5
26.5
29.5
37.5
43.5
69.5
60.0
71.5
82.0
107
157
198
241
402
563
701
1261
1794
2260
3282
4727
5687
160
235
295
360
600
840
1045
1880
2675
3370
4895
7050
8481
5000
5000
5000
5000
5000
5000
3000
3000
3000
1650
1650
1000
650
1525
1525
1525
1525
1525
1525
915
915
915
500
500
305
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
26 AWG
625152
625153
625154
625156
625157
625158
625159
625160
625161
625162
25
50
100
200
300
400
600
900
1200
1800
0.61
0.75
0.95
1.22
1.44
1.61
1.89
2.26
2.70
3.21
15.5
19.0
24.0
31.0
36.5
41.0
48.0
57.5
68.5
81.5
159
257
434
782
1114
1428
2927
2944
4003
5819
237
384
647
1166
1661
2129
3023
4390
5970
8678
5000
5000
3000
3000
3000
3000
1500
1000
1000
650
1525
1525
915
915
915
915
460
305
205
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
2
Filled Foam Skin ALPETH Cable
I. Exchange Cables
62.89.01
PE-89
REA/RUS
Outside plant telephony or underground installation.
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
ISO-9001 Quality Assurance System
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are as-
sembled to form the final core. The core is
filled with ETPR (80° C) compound. Then
covered with a non-hygroscopic tape with
an overlap. A filling compound is applied
over the wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and super-units are divided into 12 and 13
pairs sub-units.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 AND 19 AWG.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyeth-
ylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Telecordia (Bellcore) equivalent: AN_A
Meets REA/RUS PE-89
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
3
7-04
19 AWG
626136
626137
626138
626139
626140
626141
626143
626144
626145
6
12
18
25
50
75
100
200
300
0.59
0.71
0.81
0.91
1.16
1.32
1.50
2.01
2.36
15.0
18.0
20.5
23.0
29.5
33.5
38.0
51.0
60.0
141
231
308
409
744
1063
1368
2635
3856
210
345
460
610
1110
1585
2040
3930
5750
4920
4920
4920
4920
3280
3280
1640
1640
985
1500
1500
1500
1500
1000
1000
500
500
300
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
22 AWG
626120
626121
626122
626123
626124
626125
626126
626128
626129
626130
626131
626132
6
12
18
25
50
75
100
200
300
400
600
900
0.47
0.59
0.67
0.81
0.94
1.14
1.22
1.65
1.91
2.03
2.62
3.15
12.0
15.0
17.0
20.5
24.0
29.0
31.0
42.0
48.5
51.5
66.5
80.0
87
137
211
302
453
644
771
1482
2106
2602
4090
6025
130
205
315
450
675
960
1150
2210
3140
3880
6100
8985
4920
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
1500
1500
1500
1500
1500
1500
1500
1000
500
500
300
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
24 AWG
626101
626102
626103
626104
626105
626106
626107
626109
626110
626111
626112
626113
626114
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.45
0.51
0.59
0.67
0.77
0.87
0.96
1.20
1.54
1.71
2.05
2.52
2.91
11.5
13.0
15.0
17.0
19.5
22.0
24.5
30.5
39.0
43.5
52.0
64.0
74.0
70
107
144
194
302
396
506
949
1368
1680
2515
3628
5123
105
160
215
290
450
590
755
1415
2040
2505
3750
5410
7460
4920
4920
4920
4920
4920
4920
4920
3280
3280
2950
1640
1640
655
1500
1500
1500
1500
1500
1500
1500
1000
1000
900
500
500
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
Product
Code
Number of
Pairs
Nominal OD Approximate Cable Weight Standard Length
In mm Lbs/kft Kg/km Ft m
26 AWG
626081
626082
626083
626084
626086
626087
626088
626089
626090
626091
626093
626095
25
50
75
100
200
300
400
600
900
1200
1800
2400
0.55
0.59
0.77
0.89
1.08
1.30
1.46
1.69
1.93
2.30
3.00
3.19
14.0
15.0
19.5
22.5
27.5
33.0
37.0
43.0
49.0
58.5
76.0
81.0
137
228
302
369
650
925
1153
1686
2411
3239
4764
6246
205
340
450
550
970
1380
1720
2515
3640
4830
7105
9315
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
655
1500
1500
1500
1500
1500
1500
100
500
500
300
200
200
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.4
Filled Foam Skin CACSP Cable
I. Exchange Cables
62.89.02PE-89
REA/RUS
ISO-9001 Quality Assurance System
Meets REA/RUS PE-89
ANSI/ICEA S-84-608-1994.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Telecordia (Bellcore) equivalent: AN W
Outside plant telephony, direct burial or underground installation.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
ARMOR:
Corrugated shield of copolymer coated
steel tape, 6-mil thick. A flooding com-
pound with adhesive properties is applied
over the armor.
Corrugated, copolymer coated aluminum
tape, 8-mil thick applied longitudinally with
a gap. A flooding compound is applied over
the shield.
SHIELD:
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are as-
sembled to form the final core. The core is
filled with ETPR (80°C) compound. Then
covered with a non-hygroscopic tape with
an overlap. Filling compound is also applied
over the wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and superunits are divided into 12 and 13
pairs sub-units.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyeth-
ylene in distinctive colors, conforming to
telephone industry standards.
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
5
7-04
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
19 AWG
626340
626341
626342
626343
626344
626345
626346
626348
626349
6
12
18
25
50
75
100
200
300
0.59
0.71
0.85
0.91
1.16
1.32
1.50
2.01
2.36
15.0
18.0
21.5
23.0
29.5
33.5
38.0
51.0
60.0
141
231
308
409
744
1063
1368
2635
3856
210
345
460
610
1110
1585
2040
3930
5750
4920
4920
4920
4920
3280
3280
1640
1640
985
1500
1500
1500
1500
1000
1000
500
500
300
In mm Lbs/kft Kg/km Ft mProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
22 AWG
626320
626321
626322
626323
626324
626325
626326
626328
626329
626330
626331
626333
6
12
18
25
50
75
100
200
300
400
600
900
0.47
0.59
0.67
0.77
0.91
1.06
1.22
1.54
1.77
2.03
2.50
3.03
12.0
15.0
17.0
19.5
23.0
27.0
31.0
39.0
45.0
51.5
63.5
77.0
104
167
221
287
478
644
831
1482
2106
2732
4090
6120
155
248
329
427
711
960
1237
2210
3140
4055
6100
9107
4920
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
1500
1500
1500
1500
1500
1500
1500
1000
500
500
300
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
24 AWG
626300
626301
626302
626303
626304
626305
626306
626308
626309
626310
626311
626313
626315
6
12
18
25
50
75
100
200
300
400
600
900
1200
0.40
0.51
0.57
0.65
0.75
0.87
0.94
1.18
1.50
1.69
1.97
2.44
2.84
11.0
13.0
14.5
16.5
19.0
22.0
24.0
30.0
38.0
43.0
50.0
62.0
72.0
89
127
164
198
322
439
546
997
1383
1820
2615
3878
5163
132
189
244
295
480
653
812
1484
2058
2708
3891
5770
7683
4920
4920
4920
4920
4920
4920
4920
4920
3280
3280
2950
1640
1640
655
1500
1500
1500
1500
1500
1500
1500
1000
1000
900
500
500
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
26 AWG
626280
626281
626282
626283
626285
626286
626287
626288
626290
626292
626294
626296
25
50
75
100
200
300
400
600
900
1200
1800
2400
0.51
0.59
0.75
0.87
1.08
1.30
1.40
1.63
2.28
2.83
3.15
13.0
15.0
19.0
22.0
27.0
32.0
35.5
41.5
49.0
58.0
72.0
80.0
145.0
235
312
386
690
925
1156
1230
1740
2548
3382
4964
6256
215
350
465
574
1027
1436
1830
2589
3790
5032
7386
9309
4920
4920
4920
4920
4920
4920
3280
1640
1640
985
655
655
1500
1500
1500
1500
1500
1500
100
500
500
300
200
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
6
Aircore ALPETH Cable
I. Exchange Cables
REA/RUSPE-2262.22.01
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
ISO-9001 Quality Assurance System
Meets REA/RUS PE-22
ANSI/ICEA S-85-625-1996
Standard for Telecommunications Cable Air Core, Polyolefin Insulated,
Copper Conductor.
Telecordia (Bellcore) equivalent: BH A
CONDUCTORS:
Solid, annealed copper wires, in 26, 24
22 and 19 AWG.
INSULATION:
Solid, high-density polyethylene or polypropy-
lene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and crosstalk.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or
superunits of 50 or 100 pairs are as-
sembled to form the final core. All units
and superunits are identified with color
coded, non-hygroscopic, non-wicking
binders.
In order to have a rounder shape and
better electrical performance, all units and
superunits are divided into 12 and 13
pairs sub-units.
SHIELD:
Corrugated, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion.
JACKET:
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
7
7-04
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
19 AWG
626065
626066
626067
626068
626069
626070
626071
626072
626073
6
12
18
25
50
75
100
150
200
0.55
0.67
0.77
0.85
1.12
1.28
1.50
1.81
2.07
14.0
17.0
19.5
21.5
28.5
32.5
38.0
46.0
52.5
125
198
268
347
636
899
1186
1768
2326
187
295
400
517
949
1341
768
2637
3469
4920
4920
4920
3280
3280
3280
1970
1970
1970
1500
1500
1500
1000
1000
1000
600
600
600
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
22 AWG
626048
626049
626050
626051
626052
626053
626054
626055
626056
626057
626058
626059
6
12
18
25
50
75
100
150
200
300
400
600
0.43
0.52
0.55
0.63
0.79
0.91
1.04
1.22
1.38
1.63
1.87
2.32
11.0
13.0
14.0
16.0
20.0
23.0
26.5
31.0
35.0
41.5
47.5
59.0
76
115
148
190
329
460
607
895
1163
1688
2218
3292
114
171
221
284
490
686
905
1335
1734
2518
3308
4309
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
985
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
300
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
24 AWG
626025
626026
626027
626028
626029
626030
626031
626032
626033
626034
626035
626036
626037
626038
626039
626040
6
12
18
25
50
75
100
150
200
300
400
600
900
1200
1500
1800
0.39
0.47
0.51
0.55
0.71
0.81
0.87
1.04
1.18
1.40
1.57
1.87
2.28
2.60
2.85
3.11
10.0
12.0
13.0
14.0
18.0
20.5
22.0
26.5
30.0
35.5
40.0
47.5
58.0
66.0
72.5
79.0
62
81
107
133
225
314
396
596
767
1114
1447
2120
3153
4120
5085
6052
93
121
160
199
336
468
591
889
1144
16961
2158
3162
4702
6145
7583
9026
4920
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
985
985
985
655
1500
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
300
300
300
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
26 AWG
626001
626002
626003
626004
626005
626006
626007
626008
626009
626010
626011
626012
626013
626014
626015
626016
626017
12
18
25
50
75
100
150
200
300
400
600
900
1200
1500
1800
2100
2400
0.45
0.47
0.51
0.63
0.71
0.77
0.89
1.01
1.14
1.39
1.54
1.85
2.13
2.34
2.56
2.74
2.93
11.5
12.0
13.0
16.0
18.0
19.5
22.5
25.5
29.0
33.0
39.3
47.0
54.0
59.5
65.0
69.5
74.5
72
87
106
167
224
280
405
529
749
968
1405
2055
2692
3319
3964
4579
5206
106
130
158
248
334
418
604
789
1113
1443
2095
3065
4014
4949
5912
6828
7763
4920
4920
4920
4920
4920
4920
4920
3940
3940
3940
2950
1970
1310
985
985
985
985
1500
1500
1500
1500
1500
1500
1500
1200
1200
1200
900
600
400
300
300
300
300
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
8
Double Jacketed Buried Distribution Wire
62.86.01
PE-86
II. Buried Wire
(Gopher resistent)
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter of 0.0250” (0.634 mm)
INSULATION:
Solid, high-density, polyethylene or polypro-
pylene in distinctive colors, conforming to
telephone industry standards.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with a maximum length of 6.5”
(165 mm).
CORE ASSEMBLY:
The core is filled with ETPR (80°C) com-
pound, then covered with a non-hygro-
scopic tape with an overlap. A filling
compound is also applied over the wrap.
INNER JACKET
Black, linear, low-density, high molecular
weight polyethylene.
SHIELD:
Corrugated, copper-clad alloy steel (0.005”
thick) tape applied longitudinally with an
overlap. A flooding compound is applied on
both sides of the tape.
OUTER JACKET:
Black, linear, low density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Service drop for telephony, underground installation or direct burial.
Packaged on wooden reels that are lagged for additional protection.
ISO-9001 Quality Assurance System
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Cooper Conductor.
Meets REA/RUS PE-86 (for 2 and 3 pair, 22 AWG when a bronze shield - BDW B
or when a cooper clad steel armor - BDW G DJ is used)
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
9
7-04
Double Jacketed Buried Distribution Wire
62.86.01
PE-86
II. Buried Wire
(Gopher resistent)
MECHANICAL PROPERTIES
0.51 12.9 149 222 1000 or2500 or
5000
305 or760 or1520
206435873
93197396
0.44 11.1 110 162 2500 or5000
760 or1520
329633
149287
0.40 10.3 94 140 2500 or5000
760 or1520
292558
132253
In Mm Lbs/kft kg/km FT m Lbs kg
NumberOf
Pairs
2
3
6
NominalOD
Cable Net Weight Shipping Length ApproximateShipping Weight
Note: Values shown are nominal, subject to manufacturing tolerances.
INSULATION RESISTANCE, MinimumMÙ
Ù· Mile
· km
1,0001,600M
RESISTANCE UNBALANCEMaximum IndividualMaximum Average
5%1.5%
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum IndividualÙÙ
/kft
/km
17.457.1
HIGH VOLTAGE TEST, d-c kV for 3 secondsConductor to Conductor
Conductor to Shield5.0
20.0
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kftNominal dB/km
11.06.8
NEXT Near end CROSSTALK, dB/kft minimum Power Sum@772 kHz
44
FEXT Far end CROSSTALK, dB/kft minimum Power Sum@150 kHz
63
CAPACITANCE UNBALANCE: Pair to GroundIndividual Maximum
800 pF/kft2625 pF/km
CAPACITANCE UNBALANCE: Pair to pair 80 pF/kft145 pF/kmMaximum Individual
MUTUAL CAPACITANCE, average 83 7 nF/mile - 52 4 nF/km+ +
ELECTRICAL CHARACTERISTICS
10
JACKET
Black, linear, low-density, high molecular
weight polyethylene. Sequential footage (or
meter) markings are printed on the jacket
at 2 foot (or 1 m) intervals.
Filled ASP Cable, Foam Skin Insulation
I. Exchange Cables
Telecordia (Bellcore)
AN_W
62.AN_W.01
ARMOR:
A corrugated shield of steel tape, 6-mil
thick.
SHIELD:
Corrugated, bare aluminum tape, 8-mil
thick applied longitudinally with an overlap.
A flooding compound with adhesive
properties is applied over the shield.
CORE ASSEMBLY:
In cables with 25 pairs or less, the pairs
are laid forming a cylindrical shape. For
larger cables, units of 25 pairs or super-
units of 50 or 100 pairs are assembled to
form the final core. The core is filled with
ETPR (80°C) compound. Then covered with
a non-hygroscopic tape with an overlap.
Filling compound is also applied over the
wrap.
All units and superunits are identified with
color coded, non-hygroscopic, non-wicking
binders. In order to have a rounder shape
and better electrical performance, all units
and super-units are divided into 12 and 13
pair sub-units.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths to minimize capacitance unbalance
and cross-talk.
INSULATION:
Expanded polyethylene (Foam Skin) with an
external layer of solid, high-density polyethyl-
ene in distinctive colors, conforming to
telephone industry standards.
CONDUCTORS:
Solid, annealed copper wires, in 26, 24,
22 and 19 AWG.
DESCRIPTION:
Outside plant telephony, direct burial or underground installation.
APPLICATION:
PACKAGING:
Packaged on wooden reels with a thermal wrap applied over the cable.
The reels are also lagged for additional protection.
CERTIFICATION:
ISO-9001 Quality Assurance System
REFERENCE SPECIFICATIONS:
Telecordia (Bellcore)
TR-NWT-00421/3.
ANSI/ICEA 84-608-1988
Generic Requirements for metallic telecommunication cables.
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
11
7-04
Note: Values shown are nominal, subject to manufacturing tolerances.
Special lengths are available upon request.
19 AWG ANBW
626265
626266
626267
626268
626270
626271
626272
25
50
75
100
200
300
400
1.02
1.22
1.42
1.52
2.13
2.54
2.87
26.0
31.0
36.0
38.5
54.0
64.5
73.0
532
896
1228
1498
2895
4168
5423
793
1336
1832
2234
4318
6216
8088
4920
3280
3280
3280
1640
985
655
1500
1000
1000
1000
500
300
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
22 AWG
626250
626251
626252
626254
626255
626256
626257
626258
25
50
100
200
300
400
600
900
0.85
1.02
1.26
1.57
1.93
2.20
2.66
3.19
21.5
26.0
32.0
42.5
49.0
56.0
67.5
81.0
322
489
831
1408
2045
2749
3856
5633
480
730
1240
2100
3050
4100
5750
8400
5900
5900
3740
2950
2950
1970
1475
820
1800
1800
1200
900
900
600
450
250
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
24 AWG
626238
626239
626241
626243
626244
626245
626246
626247
626248
626250
25
75
100
200
300
400
600
900
1200
1800
0.73
0.87
1.04
1.36
1.57
1.81
2.11
2.56
2.99
3.56
18.5
22.0
26.5
34.5
40.0
46.0
53.5
65.0
76.0
90.5
241
349
550
972
1408
1864
2548
3805
5076
7631
360
520
820
1450
2100
2780
3800
5675
7570
11,380
5900
5900
5900
3940
3940
3280
2950
1475
1475
655
1800
1800
1800
1200
1200
1000
900
450
450
200
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
26 AWG ANTW
626220
626221
626223
626225
626226
626227
626228
626229
626230
626231
626232
25
50
100
200
300
400
600
900
1200
1800
2400
0.63
0.79
0.94
1.22
1.36
1.54
1.75
2.07
2.60
2.89
3.27
16.0
20.0
24.0
31.0
34.5
39.0
44.5
52.5
66.0
73.5
83.0
170
260
395
724
972
1240
1608
2513
3652
4256
6231
255
385
590
1080
1450
1850
2400
3750
5450
6350
9300
5900
5900
5900
5900
3940
3940
2950
1970
1475
985
820
1800
1800
1800
1800
1200
1200
900
600
450
300
250
In mm Lbs/kft Kg/km Ft m
ProductCode
Number ofPairs
Nominal OD Approximate Cable Weight Standard Length
12
62.BSW.01
Buried Service Wire
BSW A
II. Buried Wire
(Aluminium shield, single jacket)
Packaged on wooden reels that are lagged for additional protection
ISO-9001 Quality Assurance System
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Service drop for telephony, underground installation or in ducts.
SHIELD:
Smooth, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a non-
hygroscopic tape with an overlap. A filling
compound is also applied over the wrap.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with a maximum length of 6.5”
(165 mm).
INSULATION:
Solid, high-density, polyethylene or polypro-
pylene in distinctive colors, conforming to
telephone industry standards.
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter 0.0250” (0.634mm)
JACKET:
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meters)
markings are printed on the jacket at 2
foot (or 1 m) intervals.
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
13
7-04
62.BSW.01
Buried Service Wire
BSW A
II. Buried Wire
(Aluminium shield, single jacket)
INSULATION RESISTANCE, MinimumMÙ
Ù· Mile
· km
1,0001,600M
RESISTANCE UNBALANCEMaximum IndividualMaximum Average
5%1.5%
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum IndividualÙÙ
/kft
/km
17.457.1
HIGH VOLTAGE TEST, d-c kV for 3 secondsConductor to Conductor
Conductor to Shield5.0
10.0
ATTENUATION @ 150 kHz @ 20°C, Maximum IndividualNominal dB/kftNominal dB/km
11.06.8
NEXT Near end CROSSTALK, dB/kft minimum Power Sum@772 kHz
44
FEXT Far end CROSSTALK, dB/kft minimum Power Sum@150 kHz
63
CAPACITANCE UNBALANCE: Pair to GroundIndividual Maximum
800 pF/kft2625 pF/km
CAPACITANCE UNBALANCE: Pair to pairMaximum
80 pF/kft145 pF/kmIndividual
MUTUAL CAPACITANCE, average 83 7 nF/mile - 52 4 nF/km+ +
0.32 8.2 48 72 2500 762 164 75
0.29 7.4 39 58 2500 762 139 63
In Mm Lbs/kft kg/km FT m Lbs kg
NumberOf
Pairs
2
3
NominalOD
Cable Net Weight Shipping Length ApproximateShipping Weight
Note: Values shown are nominal, subject to manufacturing tolerances.
14
BDW A
Double Jacketed Buried Distribution Wire
62.BDW_A.01
II. Buried Wire
(Aluminium shield, double polyethylene jacket)
JACKET:
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meter)
markings are printed on the jacket at 2
foot (or 1 m) intervals.
SHIELD:
Smooth, copolymer coated, 8-mil thick
aluminum tape applied longitudinally with
an overlap. The coating reduces the risk of
shield corrosion. A flooding compound with
adhesive properties is applied over the
shield.
INNER JACKET
Black, linear, low-density, high molecular
weight polyethylene.
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a non-
hygroscopic tape with an overlap. A filling
compound is also applied over the wrap.
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths, with maximum length of 6.5”
(165 mm).
INSULATION:
Solid, high-density, polyethylene or polypro-
pylene in distinctive colors, conforming to
telephone industry standards.
CONDUCTORS:
Solid, annealed 22 AWG copper with a
nominal diameter of 0.0250” (0.634mm)
DESCRIPTION:
APPLICATION:
Service drop for telephony, underground installation.
PACKAGING:
Packaged on wooden reels that are lagged for additional protection.
CERTIFICATION:
ISO-9001 Quality Assurance System
REFERENCE SPECIFICATIONS:
ANSI/ICEA S-86-634-1991
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
15
7-04
BDW A
Double Jacketed Buried Distribution Wire
62.BDW_A.01
II. Buried Wire
(Aluminium shield, double polyethylene jacket)
Note: Values shown are nominal, subject to manufacturing tolerances.
MECHANICAL PROPERTIES
0.46 11.6 94 107 1000 305 148 67
0.38 9.7 63 75 5000 1524 375 170
0.35 8.9 52 62 2500 762 183 83
In Mm Lbs/kft kg/km FT m Lbs kg
NumberOf
Pairs
2
3
6
NominalOD
Cable Net Weight Shipping Length ApproximateShipping Weight
ELECTRICAL CHARACTERISTICS
INSULATION RESISTANCE, MinimumMÙ
Ù· Mile
· km
1,0001,600M
RESISTANCE UNBALANCEMaximum IndividualMaximum Average
5%1.5%
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum IndividualÙÙ
/kft
/km
17.457.1
HIGH VOLTAGE TEST, d-c kV for 3 secondsConductor to Conductor
Conductor to Shield5.0
20.0
ATTENUATION @ 150 kHz @ 20°C, Maximum IndividualNominal dB/kftNominal dB/km
11.06.8
NEXT Near end CROSSTALK, dB/kft minimum Power Sum@772 kHz
44
FEXT Far end CROSSTALK, dB/kft minimum Power Sum@150 kHz
63
CAPACITANCE UNBALANCE: Pair to Ground 800 pF/kft2625 pF/kmMaximum Individual
CAPACITANCE UNBALANCE: Pair to pairIndividual Maximum
80 pF/kft145 pF/km
MUTUAL CAPACITANCE, average 83 7 nF/mile - 52 4 nF/km+ +
16
62.BSWUSJ.01BSW USJ
Buried Service Wire
II. Buried Wire
(Non-shielded, non-armored, single jacket)
PAIRS:
Insulated conductors are twisted together
to form pairs, with different twist lay
lengths with a maximum length of 6.5”
(165 mm).
INSULATION:
Solid, high-density, polyethylene or polypro-
pylene in distinctive colors, according to
telephone industry standards.
nominal diameter 0.0250” (0.634mm) or
Solid, annealed 22 AWG copper with a,
24 AWG with a nominal diameter of 0.0201”
CONDUCTORS:
(0.511 mm)
CORE ASSEMBLY:
The core is filled with ETPR (80°C)
compound. Then covered with a non-
hygroscopic tape with an overlap. A filling
compound is also applied over wrap.
Black, linear, low-density, high molecular
weight polyethylene, able to withstand
exposure to sunlight, ground humidity and
chemicals. Sequential footage (or meter)
markings are printed on the jacket at 2
OUTER JACKET:
foot (or 1 m) intervals.
On wooden reels that are lagged for additional protection.
ISO-9001 Quality Assurance System
ANSI/ICEA S-86-634-1991.
Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
Service drop for telephony or underground installation in ducts.
subject to manufacturing tolerances.Note: Values shown are nominal,
0.37 9.5 64 95 1000 or2500 or
5000
305 or760 or1520
112215373
5198
169
0.33 8.3 47 70 5000 1520 292 132
- - - - - - - -
In Mm Lbs/kft kg/km FT m Lbs kft
NumberOf
Pairs
2
4
6
NominalOD
Cable Net Weight Shipping Length ApproximateShipping Weight
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
17
7-04
INSULATION RESISTANCE, MinimumMÙ
Ù· Mile
· km
1,0001,600M
RESISTANCE UNBALANCEMaximum IndividualMaximum Average
5%1.5%
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum IndividualÙÙ
/kft
/km
17.457.1
27.5902
HIGH VOLTAGE TEST, d-c kV for 3 secondsConductor to Conductor
Conductor to Shield5.0
10.04.0
10.0
ATTENUATION @ 150 kHz @ 20°C, Maximum IndividualNominal dB/kftNominal dB/km
11.06.8
14.087
NEXT Near end CROSSTALK, dB/kft minimum Power Sum@772 kHz
44
FEXT Far end CROSSTALK, dB/kft minimum Power Sum@150 kHz
63
CAPACITANCE UNBALANCE: Pair to GroundIndividual Maximum
800 pF/kft2625 pF/km
CAPACITANCE UNBALANCE: Pair to pairMaximum
80 pF/kft145 pF/kmIndividual
MUTUAL CAPACITANCE, average 83 7 nF/mile - 52 4 nF/km+ +
22 AWG 24 AWG
62.BSWUSJ.01BSW USJ
Buried Service Wire
II. Buried Wire
(Non-shielded, non-armored, single jacket)
Note: Values shown are nominal, subject to manufacturing tolerances.
0.37 9.5 64 95 1000 or2500 or
5000
305 or760 or1520
112215373
5198
169
0.28 7.2 32 48100025005000
305760
1520
80136217
366298
- - - - - - - -
In Mm Lbs/kft kg/km FT m Lbs kg
NumberOf
Pairs
2
4
6
NominalOD
Cable Net Weight Shipping Length ApproximateShipping Weight
18
¥
AERIAL SERVICE WIRE 62.ASW.01
¥Bare copper 22 AWG conductors
¥Galvanized steel messenger wire 2.11mm O.D.
¥Color coded to industry standards¥
DESCRIPTION:
Packaging available in reels, cartons and coils
Solid, high-density polyethylene insulation¥ Sunlight-resistant PVC jacket
¥
PROPERTIES:
* Values shown are nominal, subject to manufacturing tolerances.
MECHANICAL PROPERTIES
Pair
Count
Conductor
Diameter
(mm)
Insulation
Diameter
(mm)
Overall
Diameter
(mm)
Net
Weight
(kg/km)
3 0.643 1.1 7 x 13 67
6 0.643 1.1 9 x 15 120
ELECTRICAL PROPERTIES
c.d. Resistance
of
Conductor
(ohm/km)
DC Resistance
Unbalance
Mutual
Capacitance
(nF/km)
Capacitance
Unbalance
(Pair to Pair)
(pF/km)
Insulation
Resistance
(Megaohs-km)
56.5 5% max. 55.9 avg
58.4 max. ind.
145 max. 1600 min
Bellcore: TR-NWT-000122Bellcore: GR-492-CORE
SPECIFICATIONS:
Quality System, ISO-9000
TRANSMISSION CHARACTERISTICS
Frequency
KHz
Attenuation
dB/km
NEXT
dB/km
FEXT
dB/km
150
772 16.7 44 min.
58 min.
APPLICATIONS:
Aerial applications.z
Extending telephone circuits from a distribution terminal to a subscriber’s station protectors.z
UL Listed
Condumex Wire and Cable 2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473th
19
8-04