Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
www.idm-energie.com
High corrosion resistance and fi rstclass hyigienical standard due to
stainless steel plate heat exchanger
Saves space: one storage tank for heating and hot water
Fresh water technology for hygienic hot water and a high level of convenience
Stratifi ed storage tank technology for optimised energy use
Multivalent system for renovations and an integration of solar panels
Optimised connections for operation with heat pumps
HYGIENIK STORAGE TANK300/500/825/1.000/1.500/2.000l
FRESH WATER STATIONS25/35/50/70l/min
TECHNICAL DATA:HYGIENIK Type Unit 300/25 500/25 500/35 825/25 825/35 1000/25 1000/35 1000/50
Energy ef ficiency class 1) 1) 1) 1) 1)
Standing loss in W 89 114 114 147 147 155 155 155
Delivery output l/min 25 25 35 25 35 25 35 50
NL number* 1 4 6 5 8 6 10 15
Reservoir content Litres 311 500 825 920
One-of f delivery volume at 45°C* Litres 200 480 820 900
Dimensions (DxH) with insulation mm H 1800x W 600x D 838
1850x850 1950x1000 2150x1000
Yield measurement mm 598 650 790
Insulation thickness mm 50-100 100
Total weight, empty kg 171 100 105 115 120 125 130 135
* Once the entire Hygienik is heated to 60°C, with speed control for plate exchanger pump
Water heater for hygienic and fresh hot water with extensive additional functions, suitable for all heat generators. Storage body manufactured from steel 37.2 with all of the necessary connecting sleeves, with installation option for 1 1/2“ heating element, with large fl ange and dummy plate for installation of a solar heat exchanger; includes fl eece/soft foam insulating jacket with outer polystyrene coating, 100 mm thick, and a hot water station with fl ow switch, inclined seat valve, dirt fi lter, stainless steel plate heat exchanger and pump, completely piped. Including protective cover (Hygienik 500, Hygienik 825 and Hygienik 1000 with 25 or 35 litre module).
HYGIENIK Type Unit 1500/25 1500/35 1500/50 1500/70 2000/25 2000/35 2000/50 2000/70
Energy ef ficiency class 1) 1) 1) 1) 1) 1) 1) 1)
Standing loss in W 198 198 198 198 229 229 229 229
Delivery output l/min 25 35 50 70 25 35 50 70
NL number* 6 12 15 20 6 12 15 20
Reservoir content Litres 1500 2000
One-of f delivery volume at 45°C* Litres 1400 1800
Dimensions (DxH) with insulation mm 2350x1150 2450x1300
Yield measurement mm 950 1100
Insulation thickness mm 100
Total weight, empty kg 160 165 170 175 200 205 210 215
The iDM fresh water station en-sures a comforting supply of hygienic hot water in a matter of seconds.
The stainless steel plate heat exchanger guarantees long durabi-lity, high corrosion resistance and first class hyigienical standard.The insulation used for the iDM Hygienik
range, which incorporates a fleece and soft foam sheath, prevents a „chimney ef-fect“ from occurring in the buffer storage tank.
© iDM ENERGIESYSTEME GMBH Matrei i. Osttirol, Austria 01.2016/8183800 · iDM Hygienik product sheet EN · Changes and errors excepted.
C C C
HEAT PUMPS FROM AUSTRIALeading technology from iDM. Expertise from experts.
1) No energy effi ciency class is stated, as storage tanks with reservoir content >500 l are not within the scope of the EU-Regulation No. 812/2013 for energy labelling of space heaters and combination heaters.
THE ENERGYFAMILY
CONTROLLED HGL TECHNOLOGY WITH HYGIENIK FRESH WATER HEATING.
FIRST-GRADE TEMPERATURE LAYERINGFOR FRESH WATER CONSUMPTION:
iDM heat pumps save costs because the controlled HGL technology means more than 85% of the energy is fed into the heating circuit at 35°C. The second section reaches a temperature of 60°C, and the content is made available for hot water preparation via the Hygienik tank with fresh water technology. Water is only heated when hot water is tapped. The water in the storage tank is for heating only. As a result, hot water is always fresh and the formation of microorganisms such as Legionella and other bacteria is prevented.
• The storage tank is cooled from the bottom up• Higher temperatures remain available in the top area• The perfect layering is visible in the diagram by the severe
drop of the lines
• Very low return flow temperature in the storage tanks• Drain up to 1,800 litres of hot water at 45°C (if the 2,000l
storage tank is full at 60°C)
Heat source inlet
Heat source outlet
Evaporator Condenser
Hot water
Fresh water
Condenser
Hot water
Fresh water
iDM TERRA heat pump iDM Hygienik
Low-temperature heating
HGL fl ow 62°C
HGL exchanger
Flow 35°C
Return 30°C
Scroll compressor
Sensor colour = curve colour
1 10 40 80 100 Time in minutes
Tem
pera
ture
in °
C
80
60
40
20
0
OUR FRESH WATER TECHNOLOGY ENSURES ENHANCED COMFORT AND WELL-BEING.
iDM Hygienik combined storage tank:Water is only heated whenever you need it. The only water in the Hygienik is for heating. This means that your hot water for drinking, washing and rinsing is always fresh.
Conventional hot water tank:See below the warm water that is stored in the tank for a prolonged period of time. Mud and dirt are deposited at the bottom, which is an ideal breeding ground for germs.
Comfort through hygieneThe Hygienik buffer storage tank is a 2-in-1 layered storage tank: hot heating water is available for heating the drinking water in the upper section. The separate, lower section features the buffer storage tank for low-temperature heating. When the hot water in the shower, basin or sink is switched on, a stainless steel plate exchanger on the outside of the Hygienik system transfers the thermal energy from the heating water to the drinking water in the kitchen or bathroom, fast and hygienically.
The benefi ts to you: you use the energy from the heat pump for heating and warm water, you have no issues with Le-gionella, and you can shower or bathe in complete relaxation. This is how your energy use brings more quality to your life.
Fresh hot water
Heating fl ow
Cold water
Layer separation plate
Info: Legionella are pathogens found in water. They multiply rapidlyat temperatures between 30°C and 40°C and can cause Legi-onnaire's disease. Legionella is a serious infectious disease of the lungs which can be fatal for anyone with a weak immune system.
Cold water Heater
Hot water
Germs!Legionella! Bacteria!
Heating return
OUR HEATING SYSTEMS CAN BE CONNECTED TO ANY CONCEIVABLE HEAT SOURCE.
Inventory Heat pump Buffer tank + fresh water
Heater
Cold water
Fresh hot water
Solar plant
The Hygienik is a hot water storage tank and a drinking water heater for all existing heating systems that simulta-neously offer the hygienik fresh water system:
• Hygienik and convenient fresh water technology• Heating and warm water supply that saves
space• Feed in of existing heating systems or solar energy:
Use the fl ange with an internal heat ex-changer for small solar plant with a maxi-mum collector surface of 12m2.
Cold water Cold water