    york® airside products

    • In other types of air handling unit constructions, the majorityof air leakage occurs between the frame and the panels.This is why YMA-C units are manufactured from 88mm thicksheet metal panels insulated with CFC free PU foam. YMA-CAir Handling Units comprise an extremely rigid sealed frameconstruction, therefore gaps between panel junctions areminimal, and consequently air leakage is greatly reduced.

    • Non-metallic isolating frame around the internal perimeter

    of each panel is also included, thus eliminating thermaltransmission through the casing. An external aluminiumprole maintains structural integrity and air-tightness withoutcompromising the thermal-bridging characteristics of the unit.

    • The construction of the units achieves the highest classicationavailable for both thermal transmittance (T1) and thermalbridge factor (TB1) when measured against Eurovent teststandards of prEN 1886:2007.

    Flexibility• YMA-C Air Handling Units can be manufactured in variedcongurations, with a wide selection of components, to meetcustomer requirements.

    • To ensure maximum exibility and guarantee the best solutionfor each application, units are available in 50mm increments inboth height and width.

    • Units are also available in line with the requirements of allEuropean hospital sector specications.

    PANEL TYPECASING

    STRENGTHCASING AIRLEAKAGE

    THERMALTRANSMITTANCE

    THERMALBRIDIGING

    88 D1 L1 T1 TB1

    Mechanical characteristics-prEN 1886:2007

    Casing Materials Centrifugal Fans Filters Cooling Coils Heating Coils Heat Recovery Humidiers

    Prepainted Steel Forward Curved Panel Chilled Water Hot Water Cross Flow Electronic Steam

    Plastic Coatedsteel

    Backward Curved Bag or HEPA Direct Expansion Electric Run-Around Mains Steam

    Stainless SteelExternal motoroption

    Carbon Activated Steam Dessicant Cell

    Aluminium Plug Fan Thermal Wheel Spray

  • 8/17/2019 Hygienic AHU

    3/3

       A   i  r   H  a  n   d   l   i  n  g   S  y  s   t  e  m  s   &

       T  e  r  m   i  n  a   l    D  e  v   i  c  e  s

    Bacteria ProtectionTo protect the system from bacteria development and maximiseIndoor Air Quality, two main conditions must occur:

    1. Prevent the moist conditions that encourage bacterial andfungal development by using steam humidiers rather thanwater spray systems.

    2. Ensure that the Air Handling Unit is frequently cleaned.

    • The internal construction of the unit avoids that any of theinterior support member is exposed and ensures the internalsurface is perfectly smooth without obstructions or crevices,thus offering no sanctuary for harmful bacteria to settle andbreed and ensuring high IAQ and cleanliness levels.

    • The whole AHU interior can be made from stainless steel,and has an option for all oor panels to be sloped to givecontinuous drainage for all sections and provide maximumopportunity for internal cleaning.

    • All units can be tested for air leakage at the factory, andHEPA lter installations can also be particulate (DOP) testedto eliminate any risk of contamination from dust, dust mites,moulds, mildew, pet dander, pollen and other micro-organisms.Other components available include silencers, dampers, and arange of accessories.

    • Units can also be supplied with an on board DDC controlpackage incorporating the JCI SmartPAC control system, whichallows units to be pre-engineered, wired and tested beforeshipment. Where units are delivered in sections, a plug-and-play quick connection system allows fast installation.