71
Hydrel was launched with a mission: to make the most reliable underwater lighting the world has ever seen. This was no small task, since water is a hostile environment for lighting. But we accomplished it, and in the ensuing decades as we’ve moved up onto land, the company has continued to build its expanding lines of outdoor lighting products the same way. Rugged. Impenetrable. Uncommonly reliable. One thing is certain: Hydrel products are engineered to outperform anything on the market. It is in our DNA, and customers couldn’t be happier. Indianapolis Airport | ©2009 Hydrel JW Marriott | Gary Steffy Lighting Design Inc. | ©2009 Kevin Beswick Bay St. Louis Bridge | HNTB Corporation | ©2009 Mark McCabe First Citizens Bank | Cline Bettridge Lighting Design | ©2009 Robert Benson HYDREL 638

HYDREL - MG Industrial EléctricaHydrel was launched with a mission: to make the most reliable underwater lighting the world has ever seen. This was no small task, since water is a

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • Hydrel was launched with a mission: to make the most reliable underwater lighting the world has ever seen. This was no small task, since water is a hostile environment for lighting. But we accomplished it, and in the ensuing decades as we’ve moved up onto land, the company has continued to build its expanding lines of outdoor lighting products the same way. Rugged. Impenetrable. Uncommonly reliable. One thing is certain: Hydrel products are engineered to outperform anything on the market. It is in our DNA, and customers couldn’t be happier.

    Indianapolis Airport | ©2009 Hydrel JW Marriott | Gary Steffy Lighting Design Inc. | ©2009 Kevin Beswick Bay St. Louis Bridge | HNTB Corporation | ©2009 Mark McCabe

    First Citizens Bank | Cline Bettridge Lighting Design | ©2009 Robert Benson

    HYDREL

    638

  • HYDREL

    639

    CONTENTSIN-GRADEFlow-Through In-Grade................................................ 640-644Accessories..................................................................645, 652 Sealed In-Grade ................................................... 646-651, 653Wet-Dry In-Grade.................................................................654Technical Information...........................................................655Well Lights................................................................... 656-659

    FLOODFloodlighting.........................................660-663, 665-667, 671Accessories..................................................................664, 668Linear Floodlighting ..................................................... 672-674

    MOUNTING ACCESSORIES .....................669-670, 675-677

    LANDSCAPE LIGHTINGAccent Lighting ............................................................ 678-685

    STEP & BORDERStep Lights................................................................... 686-688Border Lights ............................................................... 689-692

    BOLLARDS ................................................................ 693-694

    AREA & WALL MOUNTEDPole Mounted.......................................................................695Building Mounted ........................................................ 696-698Site & Area Lighting.............................................................699

    UNDERWATERFountain & Refl ecting Pool Fixtures ............................. 700-704Swimming Pool Fixtures ......................................................705Accessories.................................................................. 706-707

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com640

    IN-G

    RADE

    Series20 Material Lamp type Voltage Distribution5 Lens

    M9410 Round single lensM9420 Round double lensM9430 Square single lensM9440 Square double lens

    A AluminumB BronzeSS Stainless steel

    Low voltage2

    M35M50M75P3650ILVP3675ILVIncandescent3

    P1675IP2050I

    P3075I100QFluorescent6

    18TRT26TRT32TRTCeramic metal halide35CMT47, 18

    35CMT67

    70CMT47, 18

    70CMT67

    P2035CMP3035CMP3070CM

    122

    120208240277347MVOLT4

    VNSP Very narrow spot

    NSP Narrow spot

    SP SpotMFL Medium

    floodNFL Narrow

    flood

    FL FloodWFL Wide floodVWFL Very wide floodWWD Wall wash

    distributionASY Asymmetrical

    CLC Convex lens clearCLF Convex lens frostedFLC Flat lens clearFLC5 Flat lens clear, 5° axial

    spreadFLC10 Flat lens clear, 10° tiltFLC20 Flat lens clear, 20° tiltFLSR Flat lens, slip resistantFLCAS Flat lens clear, anti-slipFLF Flat lens frosted

    Conduit entry Options Lamped Finish17

    12B 1/2" NPT bottom12S 1/2" NPT side34B 3/4" NPT bottom19

    34S 3/4" NPT side

    Internal accessories10

    IHL Honeycomb louverISS Source shield8

    LSF Linear spread filterCFAMB Color filter amberCFBLU Color filter blueCFGRN Color filter greenCFRED Color filter redWWL Wall wash louver9

    External accessories10

    GS Glare shieldLC Lexan coverRG Rock guard11

    Trims10

    BTR Bronze roundBTS Bronze squareSTR Stainless roundSTS Stainless square

    FusingSF Single fuse12

    DF Double fuse13

    Ballasts14

    GEB Electronic ballast15

    MLEBAD Electronic dimming ballast16

    LP Lamp installed BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    M9400 Intended UseThe M9400 Series modular in-grade lights are multi-purpose units designed for flush mounting in a variety of substrates or materials. The M9400 fixtures are used to uplight architectural and landscape features.

    ConstructionDoor material: Cast aluminum, cast bronze or stainless steel. Round or square with two stainless steel captive fasten-ers that lock the lamp module into the rough-in section.

    Lamp module: Stainless steel, sealed and purged of all mois-ture with silicone gaskets, stainless steel clamp band

    and single fastener. Electrical connection to lamp module is done through submersible connector with gold-plated contacts. Lamp included.

    Rough-in section: Injec-tion- molded polymer with integral junction box for branch wiring (25 cubic inches/410ccm), U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. Houses power module, lamp modules and finishing com-ponents. Adjustment ring provides 360° aim rotation with keyed section to receive lamp module. Ring locks into position with stainless steel

    fasteners. RIS has a cylinder/vault configuration.

    Double lens: Includes 360° Aim-Lock™ module support ring, door assembly, tilt ring, and module indexing seg-ment providing maintenance and relamping without re-aiming. The lamp module is suspended below the door lens in a surface-adjustable, 15° tilt mechanism. The insulating air layer reduces surface temperatures. The lenses are clear tempered flat glass.

    ElectricalPower module: Ballast is encapsulated in a custom-designed heat-dissipating

    epoxy resin to eliminate all moisture intrusion to the ballast. Provided with submersible rated cord/connector for connection to integral junction box and lamp module. HID ballasts are magnetic.

    Electrical entries/junction box: bottom or side entries available. Box suitable for through-branch wiring. Splicing volume is 25 cubic inches (410 ccm).

    ListingsU.L., C.U.L., IP68, CE, NEMKO.

    Example: M9420 B 70CMT6 MVOLT NSP FLC 34B ISS RG GEB LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    Notes1 Not available with M9430 and M9440.2 If 12V is selected, transformer will not be provided.3 Only available in 120V.4 MVOLT is only available with fluorescent and metal halide lamps with

    electronic ballasts.5 All distributions not available with all lamp types.6 Available distributions are MFL, WWD and ASY.7 Available distributions are NSP and MFL for T6; NSP, MFL and WWD

    for T4.8 Not available with PAR, MR or fluorescent lamps.9 Only valid with WWD distribution.10 Accessories are mutually exclusive. Only RG and GS can be ordered

    together. External options and trims not available with SS doors.

    11 RG is not valid with CLC or CLF lenses.12 SF available with 120V, 277V or 347V and HID only.13 DF available with 208V, 220V or 240V and HID only.14 Only available with metal halide lamps and MVOLT voltage.15 Standard on CMT4 lamps.16 For use with 0-10V analog dimmer (by others). Additional electrical

    conductors are required. Consult Hydrel for details.17 Finish only available on aluminum doors.18 Lamps available with GEB or MLEBAD electronic MVOLT only.19 Default conduit entry.20 For lens load ratings, slip resistance and temperatures, see page 655.

    Flow-Through In-Grade

    ORDERING INFORMATION

    16(40.6)9

    (22.9)

    12-1/4(31.1)

    14-1/2(36.8)

    19-1/2(49.5)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Incandescent, Low voltage, Fluorescent

    HID

    PRODUCT INFORMATION

  • HYDREL

    641www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series8 Material Lamp type Voltage LED color Distribution Lens7

    M9410 Round single lensM9420 Round double lensM9430 Square single lensM9440 Square double lens

    A AluminumB BronzeSS Stainless steel

    12LED MVOLT CLW Cool whiteCLWHO Cool white - high outputWMW Warm whiteAMB AmberBLU BlueGRN GreenRED RedRBL Royal blue

    SP SpotMFL Medium floodLSD Linear spreadWFL Wide flood

    CLC Convex lens clearCLF Convex lens frostedFLC Flat lens clearFLC10 Flat lens clear, 10° tiltFLC20 Flat lens clear, 20° tiltFLSR Flat lens, slip resistantFLCAS Flat lens clear, anti-slipFLF Flat lens frosted

    Conduit entry Options Lamped Finish5

    12B 1/2" NPT bottom12S 1/2" NPT side34B 3/4" NPT bottom6

    34S 3/4" NPT side

    Internal accessories2

    IHL Honeycomb louverLSF Linear spread filter3

    External accessories2, 4

    GS Glare shieldLC Lexan coverRG Rock guardTrims2, 4

    STS Stainless squareBTR Bronze roundBTS Bronze squareSTR Stainless square

    LP LED array installed BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    M9400Monochromatic LED

    Intended UseHydrel's M9400 series modular in-grade lights are multi-purpose units designed for uplighting architectural and landscape features.

    ConstructionDoor material: Cast alumi-num, cast bronze or stainless steel. Available in round or square door trim.

    Finish: Finish is natural alu-minum or bronze. Stainless steel door is brushed finish. Aluminum doors may be painted. See ordering guide for color options.

    Finishing section: Single or double lens design includes door assembly with 360° Aim-Lock™ lamp module sup-port ring. Module indexing provides easy maintenance and relamping without re-aiming. Active optical lenses also are available. Door trim locks into position with two stainless steel captive, tamper-resistant fasteners.

    Rough-in section: Injec-tion- molded polymer with integral junction box for through- branch wiring. The housing is U.V. stabilized, impact- and corrosion-re-

    sistant for use in all types of environments. The rough-in has a cylinder configura-tion and houses the lamp components and top door finishing section.

    ElectricalLamp type: Monochromatic LEDs, 12W LED array included.

    Lamp module: Stainless steel, sealed and purged of all moisture with silicone gaskets, stainless steel clamp band and single fastener. Electrical connection to lamp module is done through submersible connector with gold-plated contacts.

    Power module: LED driver is encapsulated in a custom-designed heat-dissipating epoxy resin that also eliminates all moisture intrusion. Module is provided with submersible rated cord leads for connection to integral junction box and lamp module.

    Conduit entry: Two (2) bottom or side entries available. Box suitable for through-branch wiring. Splicing volume is 25 cubic inches (410 ccm).

    ListingsU.L., C.U.L., IP68.

    Example: M9410 A 12LED MVOLT CLW SP CLC 12B IHL LP BL

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    9(22.9)

    16(40.6)

    10(25.4)

    9(22.9)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Not available with M9430/M9440 square model.2 Accessories are mutually exclusive; only RG and GS can be

    ordered together.3 Not available with CLC or CLF convex lens.4 Accessory not available with SS door material.5 Finish only available with aluminum material.6 Default conduit entry.7 Specify top lens. Bottom lens is FLC format.8 For lens load ratings and slip resistance, see page 655.

    Flow-Through In-Grade

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com642

    Series18 Material Lamp type Voltage Distribution Lens Conduit entry

    M9710 Round single lens

    M9720 Round double lens

    M9730 Square single lens

    M9740 Square double lens

    A AluminumB BronzeSS Stainless

    steel

    Incandescent14

    P38100IP38150IP38250I100Q150Q250QFluorescent18TRT

    26TRT32TRT42TRTMetal halide70M100M150MP3870MP38100MP38150M

    Ceramic metal halide70CMT6150CMT670CM100CM150CMP3870CMP38100CM

    High pressure sodium50S70S100S150S

    120208240277347MVOLT1

    NSP Narrow spot15

    SP Spot16

    NFL Narrow floodMFL Medium floodFL Flood17

    WFL Wide flood16

    WWD Wall wash distribution2

    FLC Flat lens clearFLC10 Flat lens clear, 10° tiltFLC20 Flat lens clear, 20° tiltFLF Flat lens frostedFLC5 Flat lens clear, 5° axial

    spread2

    FLSR Flat lens, slip resistantFLCAS Flat lens clear, anti-slipCLC Convex lens clearCLF Convex lens frosted

    12B 1/2" NPT bottom12S 1/2" NPT side34B 3/4" NPT bottom8

    34S 3/4" NPT side

    Options Lamped Finish13

    Internal accessories5

    IHL Internal honeycomb louverISS Internal source shield3

    LSF Linear spreadCFAMB Color filter amberCFBLU Color filter blueCFGRN Color filter greenCFRED Color filter redWWL Wall wash louver4

    External accessories5, 6

    GS Glare shieldLC Polycarbonate

    protective cover7

    LS Light shieldRG Rock guardTrims5, 6

    BTR Bronze trim roundBTS Bronze trim square

    STR Stainless trim roundSTS Stainless trim squareRings and masksPRR Protective ring roundPRS Protective ring squareGM Grout maskFusingSF Single fuse9

    DF Double fuse10

    Ballast11

    GEB Electronic ballastMLEBAD Electronic dimming

    ballast12

    LP Lamp installed

    BL BlackBZ BronzeDDB Dark

    bronzeDNA Natural

    aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde

    greenWH WhiteCF Custom

    IN-G

    RADE

    M9700 Intended UseHydrel's M9700 series modular in-grade lights are multi-purpose units designed for uplighting of architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials.

    ConstructionDoor material: Cast aluminum, cast bronze, cast aluminum or bronze with stainless perfo-rated trim insert, or stainless steel. Available in round or square door trim.

    Finish: Finish is natural aluminum or bronze. Stain-less steel door is brushed finish. Aluminum doors may be painted.

    Rough-in section: Injection-molded polymer with integral junction box for through-branch wiring. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. The rough-in section has a cylin-der/vault configuration and houses the lamp and power module components and top door finishing section.

    Lamp module: Stainless steel housing, factory-sealed and purged of all moisture for longer component life. Lens is sealed with silicone gasket and stainless steel clamp band assembly with single fastener. Electrical connection to lamp module is

    done through a submersible quick-pull plug connector with gold-plated contacts. Standard unit is thermally protected. Lamp included.

    Finishing section: Single lens design includes door as-sembly with 360° Aim-LockTM lamp module support ring. Module indexing provides easy maintenance and re-lamping without re-aiming. Active optical lenses are also available. Door trim locks into position with two stainless steel captive, tamper-resistant fasteners.

    ElectricalPower module: Ballast is encapsulated in a custom-designed heat-dissipating ep-

    oxy resin that also eliminates all moisture intrusion to the ballast. Module is provided with submersible rated cord leads for connection to inte-gral junction box and lamp module. Standard ballast is high power factor, fluorescent electronic or HID magnetic.

    Conduit entry: Two (2) bottom or side entries available. Box suitable for through-branch wiring. Splicing volume is 25 cubic inches (410 ccm).

    ListingsU.L., C.U.L., IP68, CE, NEMKO.

    Example: M9710 B 150CMT6 120 NSP FLC 34B ISS GS LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    12(30.5)

    12(30.5)

    12” Bronze or Aluminum Square 13” Stainless Steel Square

    12” Bronze or Aluminum Round 13” Stainless Steel Round

    13(33.0)

    13(33.0)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    12(30.5)

    12(30.5)

    16(40.7)

    20(50.8)

    Incandescent

    HID, Fluorescent

    Flow-Through In-Grade

    Notes1 Standard on fluorescent and metal halide lamps with electronic ballast option.2 FLF5 lens recommended for 70W HID and lower. FLC5 lens recommended for 100W HID and

    higher with WWD distribution.3 ISS not available with PAR or fluorescent lamps, or WWD distribution.4 Not available with PAR lamps.5 Accessories are mutually exclusive. Choose one.6 Not available with SS material.7 LC not available for M9710, M9730.8 Default coduit entry.9 SF available with 120V, 277V or 347V HID only.10 DF available with 208V, 220V or 240V HID only.11 Available with MVOLT (120V-277V) voltage only for metal halide lamps to 150W maximum.12 For use with O-10V analog dimmer (by others). Additional electrical conductors are required.

    Consult Hydrel for details.13 Finish only available on aluminum doors.14 Incandescent models available with 120V only.15 NSP only available with T4 or T6 lamps.16 Not available with T6 lamps.17 Only available with PAR lamps.18 For lens load ratings, slip resistance and temperatures, see page 655.

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    643www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series8 Material Lamp type LED color Voltage Distribution Lens

    M9710 Round single lensM9720 Round double lensM9730 Square single lensM9740 Square double lens

    A AluminumB BronzeSS Stainless steel

    22LED CLW Cool whiteCLWHO Cool white high outputWMW Warm whiteAMB AmberBLU BlueGRN GreenRED RedRBL Royal blue

    1206

    MVOLTSP SpotMFL Medium floodLSD Linear spread distributionWFL Wide flood

    FLC Flat lens clearFLC10 Flat lens clear, 10° tiltFLC20 Flat lens clear, 20° tiltFLF Flat lens frostedFLCAS Flat lens clear, anti-slipFLSR Flat lens, slip resistantCLC Convex lens clearCLF Convex lens frosted

    Conduit entry Options Lamped Finish5

    12B 1/2" NPT bottom12S 1/2" NPT side34B 3/4" NPT bottom7

    34S 3/4" NPT side

    Internal accessories2

    IHL Internal honeycomb louverLSF Linear spreadExternal accessories2, 3, 4

    GS Glare shieldLC Polycarbonate protective coverRG Rock guard

    Trims2, 4

    BTR Bronze trim roundBTS Bronze trim squareSTR Stainless trim roundSTS Stainless trim squareDimmingLDIM 0-10V Dimming6

    LP Lamp included BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    M9700Monochromatic LED

    Intended UseHydrel's M9700 series modular in-grade lights are multi-purpose units designed for uplighting of architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials.

    ConstructionDoor material: Cast aluminum, cast bronze, cast aluminum or bronze with stainless perfo-rated trim insert, or stainless steel. Available in round or square door trim.

    Rough-in section: Injection-molded polymer with integral junction box for through-branch wiring. The housing is U.V. stabilized,

    impact- and corrosion-re-sistant for use in all types of environments. The rough-in section has a cylinder/vault configuration and houses the lamp and power module components and top door finishing section.

    Lamp module: Stainless steel housing, factory-sealed and purged of all moisture for longer component life. In the double lens units, the lamp module is suspended below the top door lens in a surface-adjustable, 15° tilt mechanism. The insulating air layer helps to reduce surface temperatures. Lens is sealed with silicone gasket and stainless steel clamp band assembly with

    single fastener. Electrical connection to lamp module is done through a submersible quick-pull plug connector with gold-plated contacts. Lamp included.

    Finishing section: Includes door assembly with 360° Aim-Lock™ lamp module sup-port ring. Module indexing provides easy maintenance and relamping without re-aiming. Active optical lenses also are available. Door trim locks into position with two stainless steel captive, tamper-resistant fasteners.

    Finish: Natural aluminum or bronze. Stainless steel door is brushed finish. Aluminum doors may be painted.

    ElectricalLamp type: Monochromatic LED, 22W.

    Power module: LED driver is encapsulated in a custom-designed heat-dissipating ep-oxy resin that also eliminates all moisture intrusion. Module is provided with submersible rated cord leads for connec-tion to integral junction box and lamp module.

    Conduit entry: Two (2) bottom or side entries available. Box suitable for through-branch wiring. Splicing volume is 25 cubic inches (410ccm).

    ListingsU.L.,C.U.L., IP68.

    Example: M9710 A 22LED RBL 120 SP FLC 34B IHL LP BL

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    12(30.5)

    12(30.5)

    12” Bronze or Aluminum Square 13” Stainless Steel Square

    12” Bronze or Aluminum Round 13” Stainless Steel Round

    13(33.0)

    13(33.0)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    12(30.5)

    16(40.7)

    LED rough-in housingNotes1 Not available with M9730 or M9740 square model.2 Accessories are mutually exclusive; choose one only.3 Not available with CLC or CLF convex lens.4 Accessory not available on "SS" door material.5 Finish only available on aluminum door material.6 Dimming available with 120V only.7 Default conduit entry.8 For lens load ratings and slip resistance, see page 655.

    Flow-Through In-Grade

    ORDERING INFORMATION

    Visit www.hydrel.com for color changing LED specifications.

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com644

    IN-G

    RADE

    Series13 Material Lamp type Voltage Distributions Lens

    M9820 Round double lens A AluminumB Bronze

    Incandescent1

    P64500I PAR64, ext. mogul end prong10

    P56300I PAR56, mogul end prong10

    Metal Halide200M E28, mogul250M E28, mogul320M E28, mogul

    400M E37, mogulHigh Pressure Sodium250ST E18, mogul 400ST E18, mogul

    120208220240277347

    SP SpotNSP Narrow spot2

    MFL Medium floodWFL Wide flood2

    WWD Wall wash10

    VNSP Very narrow spot2

    FLC Flat lens clear3

    FLC5 5° axial spreadFLC10 Flat lens clear, 10° tiltFLC20 Flat lens clear, 20° tilt

    Conduit entry Options Lamped Finish11

    1B 1" NPT bottom12B 1/2" NPT bottom12S 1/2" NPT side4

    34B 3/4" NPT bottom12

    34S 3/4" NPT side4

    Internal accessories6

    ISS Internal source shield5,10

    IHL Internal honeycomb louverWWL Wall wash louverExternal accessories6

    GS Glare shieldRG Rock guard

    Trim ringBTR Bronze trim ringSTR Stainless trim ringFusingSF Single fuse7

    DF Double fuse8

    BallastSCWA Super constant wattage ballast9

    LP Lamp installed BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom finish

    M9800 Intended UseThe M9800 series modular in-grade lights are multi-pur-pose units designed for flush mounting in soil or concrete. The units consist of a factory- sealed, thermally protected lamp module and epoxy encapsulated power module placed in a secured rough-in section (RIS) which includes channeled convective cool-ing, an integral junction box and door assembly.

    ConstructionFinishing section: Includes 360° Aim-Lock™ support ring, door assembly, tilt ring,

    and module indexing seg-ment providing maintenance and relamping without re-aiming. The lamp module is suspended below the door lens with a surface-adjust-able, 10° tilt mechanism. The insulating air layer reduces surface temperatures. Doors available in cast aluminum or cast bronze, round. Two stainless steel captive fasten-ers lock the finishing section into the rough-in section.

    Rough-in section: Injection- molded polymer cylinder with integral junction box for branch wiring (75 cubic

    inches /1230ccm), U.V. stabi-lized, impact- and corrosion-resistant for use in many environments. Houses power module, lamp modules and finishing components.3

    ElectricalLamp type: Incandescent – PAR64 500W max. HID – E23, E28, E37 and elliptical to 400W.

    Socket: Incandescent - Mogul end prong or GX16D base. HID - Mogul or E40 base.

    Power module: Ballast is encapsulated in a custom-designed heat-dissipating epoxy resin to eliminate

    all moisture intrusion to the ballast. Provided with submersible rated cord/connector for connection to integral junction box and lamp module. HID ballasts are magnetic.

    Conduit entry: Two (2) bottom or side entries available. Box suitable for through-branch wiring. Splicing volume is 25 cubic inches (410 ccm).

    Listings U.L., C.U.L., CE, NEMKO, IP68.

    Example: M9820 A 400M 277 SP FLC 34B ISS SF LP BZ

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    18(45.7)

    18(45.7)

    27-1/2(69.9)

    18(45.7)

    16-1/8(41.0)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Incandescent models available with 120V only.2 Only available with PAR lamps.3 FLC will be used if lens is not chosen except for WWD distribution, then

    FLC5 will be used.4 Not available with incandescent lamps.5 Not available with WWD distribution.6 Mutually exclusive; choose only one.7 SF is only available with 120V, 277V or 347V on HID only.8 DF is only available with 208V, 220V or 240V on HID only.9 Standard on all metal halide lamps.10 WWD and ISS not available with P56300I, P64500I.10 Paint finish only available on aluminum doors12 Default conduit entry.13 For lens load ratings, slip resistance and temperatures, see page 655.

    Flow-Through In-Grade

    ORDERING INFORMATION

    HID

    Incandescent

    PRODUCT INFORMATION

  • HYDREL

    645www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADEAccessories

    Installation Accessories Safety Accessories

    BTR Bronze trim ring STR Stainless trim ring RG Rock guard, bronze or aluminum LC Polycarbonate protective cover

    GS Glare shield, bronze or aluminum

    Light Control Accessories

    IHL Internal honycomb louver WWL Wall wash louver ISS Internal source shield

    FLC5 5° Axial spread lens FLC10 10° tilt lens FLC20 20° tilt lens

    Door Material Options

    A Aluminum door B Bronze door SS Stainless steel door

    M9000Accessories and Door Material

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com646

    IN-G

    RADE

    Series Material Lamp type Voltage Distribution Lens Conduit entry Options2, 4 Lamped

    PDX4 In-grade5

    PDX4ML Marker light

    SS Stainless steel

    BSS Brushed stainless steel2

    B Bronze

    M20 MR16, GX5.3, 20W max.M35 MR16, GX5.3, 35W max.M50 MR16, GX5.3, 50W max.MR1120 MR11, GU4, 20W max.MR1135 MR11, GU4, 35W max.

    121

    120PDX4NSP Narrow

    spot 3

    SP SpotNFL Narrow

    floodWFL Wide

    flood3

    FL Flood3

    PDX4MLML180 180°ML360 360°

    FLC Flat lens clearFLCAS Flat lens clear,

    anti-slip2

    FLSR Flat lens, slip resistant2

    12S Two 1/2" NPT side (standard)

    12B Two 1/2" NPT bottom

    Internal accessoriesIHL Internal

    honeycomb louver

    LSF Linear spread filter

    CFAMB Color filter amberCFBLU Color filter blueCFGRN Color filter greenCFRED Color filter red

    LPI Lamp included

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel.

    Housing: Die-cast bronze and injection-molded thermoplastic. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments.

    Finish: Natural bronze or stain-less steel with a brushed finish.

    OpticsLens/seal: Tempered clear flat borosilicate glass. The patent-pending door/lens seal uses proprietary knife edge technology to secure the assembly to the housing.

    Two captive screws hold the assembly in place. The lens is notched to provide maximum aperture opening.

    ElectricalLamp: MR16 GX5.3 base or MR11GU4 base. Conduit en-try: Two 1/2" NPT side entries standard, two 1/2" bottom entries are optional.

    Power supply: Optional inte-grally mounted transformer, prewired for easy installation and maintenance.

    ListingsU.L., C.U.L.,CSA-U.S., CSA, IP68.

    Example: PDX4 B M35 120 NSP FLC 12S IHL LPI

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    4(10.2)

    5(12.7)

    5(12.7)

    4(10.2)

    8(20.3)

    5(12.7)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Low voltage Line voltage

    In-grade

    Low voltage Line voltage

    Marker Light

    5(12.7)

    5(12.7)

    8(20.3)

    5(12.7)

    3-7/8(9.9)

    3-7/8(9.9)

    Notes1 Transformer sold separately.2 Only available if PDX4 is chosen.3 Not available with MR11 lamps.4 Only one accessory available.5 For lens load ratings, slip resistance and temperatures, see page 655.

    PDX4Paradox™ 4" Architectural In-Grade

    Sealed In-Grade

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    647www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series MaterialLamp type LED color Voltage Distribution Lens Conduit entry Options Lamped

    PDX4 In-grade3

    PDX4ML Marker light

    SS Stainless steelBSS Brushed stainless

    steel1

    B Bronze

    9LED CLW Cool whiteWMW Warm whiteAMB AmberBLU BlueGRN GreenRED RedRBL Royal blue

    122

    MVOLTPDX4SP SpotMFL Medium

    floodPDX4MLML180 180° ML360 360°

    FLC Flat lens clearFLCAS Flat lens clear,

    anti-slip1

    FLSR Flat lens, slip resistant1

    12S Two 1/2" NPT side (standard)

    12B Two 1/2" NPT bottom

    TKO Tilt kit optic1

    LPI LED array included

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel.

    Housing: Die-cast bronze and injection-molded thermoplastic. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments.

    Finish: Natural bronze or stain-less steel with a brushed finish.

    Lens/seal: Tempered clear flat borosilicate glass. The patent-pending door/lens seal uses proprietary knife edge technology to secure the assembly to the housing. Two captive screws hold the assembly in place. The lens is

    notched to provide maximum aperture opening.

    ElectricalLED: Monochromatic LED, 9W.

    Conduit entry: Two 1/2" NPT side entries standard; two 1/2" bottom entries are optional.

    Power supply: Integrally mounted modular LED driver, prewired for easy installation and maintenance.

    ListingsCSA-U.S., CSA, IP68.

    Example: PDX4 B 9LED CLW MVOLT SP FLC 12S TKO LPI

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    4(10.2)

    5(12.7)

    5(12.7)

    4(10.2)

    8(20.3)

    5(12.7)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    5(12.7)

    5(12.7)

    8(20.3)

    5(12.7)

    3-7/8(9.9)

    3-7/8(9.9)

    Notes1 Only available if PDX4 is chosen.2 Transformer sold separately.3 For lens load ratings and slip resistance, see page 655.

    Sealed In-Grade

    ORDERING INFORMATION

    PDX4Paradox™ 4" Architectural In-Grade

    Monochromatic LED

    Low voltage Line voltage

    In-grade

    Low voltage Line voltage

    Marker Light

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com648

    IN-G

    RADE

    Series22 Material Lamp type Voltage Distribution

    PDX7 In-gradePDX7CL In-grade

    with cool lens

    SS Stainless steel

    BSS Brushed stainless steel12

    B Bronze

    Low voltage1

    M20 MR11, GZ4 M35 MR11, GZ4 M50 MR16, GX5.3 M75 MR16, GX5.3 P3650 PAR36, screw terminal P3675 PAR36, screw terminal AR11135 G53

    AR11150 G53AR11175 G53Incandescent2

    P2050I PAR20, medium P3050I PAR30, medium HID20MHCP PGJ59

    20MHCG GU6.510

    20CMT4 T4, G8.511, 17

    35CMT4 T4, G8.570CMT4 T4, G8.511, 17

    35CMT6 T6, G1218

    70CMT6 T6, G1218

    P2035CM PAR20, medium P3035CM PAR30, medium P3070CM PAR30, medium

    R11135CM GX8.5R11170CM GX8.5Fluorescent 4 , 13

    18TRT Triple tube, GX24q2

    26TRT Triple tube, GX24q3

    123

    120208240277347MVOLT5

    NSP Narrow spotSP SpotNFL Narrow floodMFL Medium floodWFL Wide floodFL Flood19

    WWD Wall wash distribution6

    Lens Conduit entry Options Lamped

    FLC Flat lens clearFLCAS Flat lens clear, anti-slip12

    FLSR Flat lens, slip resistant12

    34S Two 3/4" NPT side (standard) Internal accessoriesIHL Internal honeycomb louver16

    ISS Internal source shield7

    WWL Wall wash internal louver8

    LSF Linear spread filterCFAMB Color filter amberCFGRN Color filter greenCFRED Color filter red

    External accessoriesRG Decorative rock guardGS Glare shield21

    FusingSF Single fuse14

    DF Double fuse15

    BallastGEB Electronic ballast20

    LPI Lamp included

    PDX7Paradox™ 7" Architectural In-Grade

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel, available with die-cast brass extension for cool application.

    Housing: Compression- molded polyester with patent-pending internal direct access junction box for through-branch wiring. Internal junction box pro-vides 44 cubic inches volume to ensure proper seal during installation. The housing is

    U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. The housing has a sidecar configuration and houses the lamp and power module components as well as the lens/door finishing section.3

    Lens/seal: Tempered clear flat borosilicate glass. The patent-pending door/lens seal uses proprietary knife edge technology to secure the assembly to the housing. Three captive screws hold the assembly in place. The lens is notched to provide maximum aperture opening.

    Finish: Natural bronze or stainless steel with a brushed finish. Bronze doors may be painted. Consult factory for color options.

    OpticsReflectors (non-reflectorized lamps): High-purity anodized

    specular or semi-specular materials in various distribu-tions provide maximum performance and uniformity. Lamps can be aimed 15° from vertical and rotated 360°. All configurations available with Hydrel's patented Aim-Lock™ locking components to allow re-lamping and maintenance without re-aiming.

    ElectricalLow voltage: MR11 GZ4 base, 35W max. MR16 GX5.3 base, 75W max., PAR36 screw ter-minal base, 75W max. AR111 G53 base, 75W max.

    Incandescent: PAR20, PAR30, medium base.

    HID: T4 or T6 bi-pin base, 70W max PAR-20 or PAR-30 medium base, 70W max color corrected metal halide.

    Fluorescent: Triple-tube CFL 4-pin base, 26W max.

    If a specific lamp is desired, specify manufacturer's lamp number; most lamps can be supplied. Lamp included.

    Conduit entry: Two molded 3/4" NPT side entries standard; bottom hubs are molded with a 3/4" NPT membrane knockout.

    Ballast: Integrally mounted modular ballast package, prewired with quick con-nectors for easy installation and maintenance. Ballasts are rated for low starting temperatures. High power factor magnetic ballasts standard; electronic ballasts also available.

    ListingsU.L., C.U.L.

    Example: PDX7 B 35CMT6 120 NSP FLC 34S RG LPI

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    9(22.9)

    15(38.1)

    5(12.7)

    8(20.3)

    7(17.8)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted. Notes

    1 Low voltage only available with 12V, 120V, 240V, 277V inputs.

    2 Incandescent models are available with 120V only.3 Available for low voltage lamps only.4 18TRT or 26TRT available with MVOLT only.5 Available with HID if GEB chosen, standard with

    fluorescent lamps.6 Available with T4 G8.5 base, 20MH PGJ5 base, and

    20MH GU6.5 base.7 Available with T6 and T4 lamps in NSP distribution

    only. Not valid with WWD.8 Available with HID if GEB chosen, standard with

    fluorescent lamps.9 Philips Mini MasterColor available in 20W and 120V

    GEB only.

    10 GE Mini UltraMax available in 20W and120V GEB only.

    11 20CMT4, 35CMT4 or 70CMT4 only valid with MVOLT and GEB.

    12 Not available with decorative rock guard.13 Available only in MFL light distribution.14 SF is available only with 120V, 277V or 347V on HID.15 DF is available only with 208V, 220V or 240V on HID.16 IHL not available with color filters.17 Available with NSP, MFL and WWD only.18 Available with NSP, MFL and WFL only.19 Only available with PAR lamps.20 HID only.21 SS door only.22 For lens load ratings, slip resistance and tempera-

    tures, see page 655.

    Sealed In-Grade

    ORDERING INFORMATION

    15(38.1)

    10(25.4)

    5(12.7)

    Standard Housing Cool Lens Housing

    PRODUCT INFORMATION

  • HYDREL

    649www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series3 Material Lamp type LED color Voltage Distribution Lens Conduit entry Options Lamped

    PDX7 SS Stainless steelBSS Brushed

    stainless steel1

    B Bronze

    12LED CLW Cool whiteCLWHO Cool white - high

    outputWMW Warm whiteAMB AmberBLU BlueGRN GreenRED RedRBL Royal blue

    MVOLT SP SpotMFL Medium floodWFL Wide floodLSD Linear spread

    distribution

    FLC Flat lens clearFLCAS Flat lens clear,

    anti-slip1

    FLSR Flat lens frosted, slip resistant1

    34S Two 3/4" NPT side (standard)

    Internal accessoriesIHL Internal

    honeycomb louver

    External accessoriesRG Decorative rock

    guardGS Glare shield2

    LPI LED array included

    PDX7Paradox™ 7" Architectural In-Grade

    Monochromatic LED

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel.

    Housing: Compression- molded polyester with patent-pending internal direct-access junction box for through-branch wiring. Internal junction box pro-vides 44 cubic inches volume to ensure proper seal during installation. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. The housing has a sidecar configuration and houses the lamp and power module components as well as the lens/door finishing section.

    Finish: Natural bronze or stainless steel with a brushed finish.

    OpticsLens/seal: Tempered clear flat borosilicate glass. The patent-pending door/lens seal uses proprietary knife edge technology to secure the assembly to the housing. Three captive screws hold the assembly in place. The lens is notched to provide maximum aperture opening.

    ElectricalLED: Monochromatic LEDs, 12W.

    Conduit entry: Two molded 3/4" NPT side entries standard; bottom hubs are molded with a 3/4" NPT membrane knockout.

    Power module: Integrally mounted modular LED driver, prewired with quick connec-tors for easy installation and maintenance.

    ListingsU.L., C.U.L.

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    9(22.9)

    15(38.1)

    5(12.7)

    8(20.3)

    7(17.8)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Not available with decorative rock guard.2 SS door only3 For lens load ratings and slip resistance, see page 655.

    Sealed In-Grade

    Example: PDX7 B 12LED CLW MVOLT SP FLC 34S LPIORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com650

    IN-G

    RADE

    Series14 Material Lamp type Voltage Distribution

    PDX10 In-gradePDX10CL In-grade with

    cool lens

    SS Stainless steelBSS Brushed

    stainless steel8

    B Bronze

    Incandescent1

    P3050I PAR30, mediumP38100I PAR38, mediumP3075I PAR30, mediumP38150I PAR38, medium100Q T4, mini can 150Q T4, mini canFluorescent3, 9

    18TRT Triple tube, GX24q226TRT Triple tube, GX24q332TRT Triple tube, GX24q342TRT Triple tube, GX24q3

    Metal halide35CMT4 T4, G8.57

    70CMT4 T4, G8.57

    P3035CM PAR30 medium2

    P3070CM PAR30 medium2

    R11135CM GX8.52

    R11170CM GX8.52

    35CMT6 T6, G-122

    70CMT6 T6, G-12150CMT6 T6, G-122

    50M E17, medium2

    70M E17, medium70CM E17, medium100M E17, medium100CM E17, medium150M E17, medium2

    150CM E17, medium2

    P3870M PAR38, medium10

    P3870CM PAR38, medium10

    P38100M PAR38, medium10

    P38100CM PAR38, medium10

    High pressure sodium50S E17, medium2

    70S E17, medium100S E17, medium150S E17, medium

    120208220240277347MVOLT4

    NSP Narrow spot11

    SP SpotNFL Narrow floodMFL Medium floodWFL Wide floodFL FloodWWD Wall wash

    distribution

    Lens Conduit entry Options Lamped

    FLC Flat lens clearFLCAS Flat lens clear, anti slip8

    FLCSR Flat lens frosted, slip resistant8

    34S Two 3/4" NPT side (standard) Internal accessoriesIHL Internal honeycomb louverISS Internal source shield5

    WWL Wall wash internal louver6

    LSF Linear spread filterCFAMB Color filter amberCFBLU Color filter blueCFGRN Color filter greenCFRED Color filter red

    External accessoriesRG Decorative rock guardFusingSF Single fuse12

    DF Double fuse13

    BallastGEB Electronic ballast4

    LPI Lamp included

    PDX10Paradox™ 10" Architectural In-Grade

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel.

    Housing: Compression- molded polyester with patent-pending internal direct-access junction box

    for through-branch wiring. Internal junction box pro-vides 44 cubic inches volume to ensure proper seal during installation. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. The housing has a sidecar configuration and houses the lamp and power module components as well as the lens/door finishing section.

    Lens/seal: Tempered clear flat borosilicate glass. The patent-pending door/lens seal uses proprietary knife edge technology to secure the assembly to the housing.

    Four captive screws hold the assembly in place. The lens is notched to provide maximum aperture opening.

    OpticsReflector (non-reflectorized lamps): High-purity anodized specular or semi-specular materials in various distribu-tions provide maximum performance and uniformity. Lamps can be aimed 15° from vertical and rotated 360°. All configurations available with indexed and locking compo-nents to allow re-lamping and maintenance without re-aiming.

    ElectricalConduit entry: Two molded 3/4" NPT side entries standard; bottom hubs are molded with a 3/4" NPT membrane knockout.

    Ballast: Integrally mounted modular ballast package, prewired with quick con-nectors for easy installation and maintenance. Ballasts are rated for low starting temperatures. High power factor magnetic ballasts standard; electronic ballasts also available.

    ListingsU.L., C.U.L.

    Example: PDX10 B 35CMT6 120 NSP FLC 34S RG LPI

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    12(30.5)

    12(30.5)

    18(45.7)

    10(25.4)

    6(15.2)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Incandescent models are available with 120V only.2 220V not available.3 Available with MVOLT only.4 If GEB and HID lamp source are chosen, use MVOLT.5 Available with E17, T6 and T4 lamps in NSP distribution only.

    Not valid with WWD.6 Available only with WWD distributions or TRT lamps.7 35CMT4 or 70CMT4 only valid with MVOLT and GEB.8 Not available with decorative rock guard.9 Available only in MFL, WWD or WFL light distribution.10 PAR38 lamps only available with SP or FL distributions.11 NSP only valid with T4 or T6 lamps.12 SF is available only with 120V, 277V or 347V on HID.13 DF is available only with 208V, 220V or 240V on HID.14 For lens load ratings, slip resistance and temperatures,

    see page 655.

    Sealed In-Grade

    ORDERING INFORMATION

    18(45.7)

    14(35.7)

    Standard Housing Cool Lens Housing

    PRODUCT INFORMATION

  • HYDREL

    651www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series4 Material Lamp type LED color Voltage Distribution Lens

    PDX10 SS Stainless steelBSS Brushed

    stainless steel1

    B Bronze

    22LED 22W CLW Cool whiteCLWHO Cool white, high outputWMW Warm whiteAMB AmberBLU BlueGRN GreenRED RedRBL Royal blue

    1202

    MVOLTSP Spot, clear flat lensMFL Medium flood, clear flat lensWFL Wide flood, clear flat lensLSD Linear spread distribution, clear flat lens

    FLC Flat lens clearFLCAS Flat lens clear, anti slip1

    FLSR Flat lens frosted, slip resistant1

    Conduit entry Options Lamped

    34S Two 3/4" NPT side (standard)

    Internal accessoriesIHL Internal honeycomb louverExternal accessoriesRG Decorative rock guardBallastLDIM 0-10V dimming3

    LPI Lamp included

    PDX10Paradox™ 10" Architectural In-Grade

    Monochromatic LED

    Intended UseHydrel's Paradox Series sealed modular in-grade luminaires are multi-purpose units designed for uplighting architectural and landscape features. These units can be flush-mounted into a variety of substrates or landscape materials, and are ideal when aperture size or luminaire depth is a priority.

    ConstructionDoor material: Die-cast bronze or stainless steel.

    Housing: Compression-molded polyester with

    patent-pending internal direct-access junction box for through-branch wiring. Internal junction box pro-vides 44 cubic inches volume to ensure proper seal during installation. The housing is U.V. stabilized, impact- and corrosion-resistant for use in all types of environments. The housing has a sidecar configuration and houses the lamp and power module components as well as the lens/door finishing section.

    OpticsLens ⁄seal: Tempered clear flat borosilicate glass. The

    patent-pending door⁄ lens seal uses proprietary knife edge technology to secure the assembly to the housing. Four captive screws hold the assembly in place. The lens is notched to provide maximum aperture opening.

    ElectricalLED type: 22W Monochro-matic or color changing. Conduit entry: Two molded 3/4" NPT side entries standard; bottom hubs are molded with a 3/4" NPT membrane knockout.

    Power module: Integrally mounted modular LED driver, prewired with quick connectors for easy installa-tion and maintenance. Control: Standard DMX512. 3-channels per fixture: Red, Green, Blue or 4.

    Communication to fixture: DMX512 direct.

    ListingsU.L., C.U.L.

    Example: PDX10 SS 22LED CLW MVOLT SP FLC 34S IHL LPI

    Sealed In-Grade

    12(30.5)

    12(30.5)

    18(45.7)

    10(25.4)

    6(15.2)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    Notes1 Not available with RG option.2 Only valid with LDIM.3 Only valid with 120V.4 For lens load ratings, slip resistance and

    temperatures, see page 655.

    ORDERING INFORMATION

    Monochromatic Housing

    Visit www.hydrel.com for color changing LED specifications.

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com652

    AccessoriesIN-G

    RADE

    PARADOX™

    RG Decorative Rock Guard

    WWL Wallwash Louver IHL Internal Honeycomb Louver ISS Internal Source Shield GS Glare Shield Stainless Steel(PDX7 only)

    TKO 5° Tilt Lens Filter(PDX4 only)

    TKO 10° Tilt Lens Filter(PDX4 only)

    TKO 15° Tilt Lens Filter(PDX4 only)

    TKO kit includes 5°, 10° and 15° tilt fi lters and the 5° axial spread fi lter.

    TKO 5° Axial Spread Filter

    FLCAS Anti-Slip Lens FLSR Slip-Resistant Lens

    Safety Accessories

    Light Control Accessories

    NotesFor visual representation only; not scaled proportionately.

    PRODUCT INFORMATION

  • HYDREL

    653www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series Material Lamp type Voltage Distribution Lens15

    6700 B Bronze Incandescent1

    P3050IP3075IP38100IP38150IP38250I100Q250Q

    Fluorescent2

    18TRT26TRT32TRT42TRTMetal halide100M150MP38100MP3870M

    Ceramic metal halide70CMT6150CMT670CM100CM150CMP38100CMP3870CM

    High pressure sodium50S70S100S150S

    120208240277347MVOLT3

    SP Spot5

    NSP Narrow spot4

    NFL Narrow floodFL Flood5

    MFL Medium floodWFL Wide flood5

    WWD Wall wash distribution

    CLC Convex lens clearCLF Convex lens frostedFLC Flat lens clearFLC5 Flat lens clear, 5° axial spreadFLC10 Flat lens clear, 10° tiltFLF Flat lens frostedFLC20 Flat lens clear, 20° tiltFLCAS Flat lens clear, anti-slip

    Conduit entry Options15 Lamped

    12B 1/2" NPT bottom34B 3/4" NPT bottom (default)12S 1/2" NPT side34S 3/4" NPT side

    Internal accessoriesIHL Internal honeycomb louverISS Internal source shield6

    WWL Wall wash louver7

    ITB Internal tilt bracket14

    FiltersLSF Linear spread filterCFAMB Color filter amber13

    CFBLU Color filter blue13

    CFGRN Color filter green13

    CFRED Color filter red13

    External accessories8

    GS Glare shieldLS Light shieldRG Rock guard9

    BTR Bronze trim round

    FusingSF Single fuse10

    DF Double fuse11

    Ballast12

    GEB Electronic ballast

    LP Lamp installed

    6700Intended UseThe 6700 Series sealed outdoor lighting fixture offers high performance and durability in an in-grade fix-ture. Many lamping options and distributions are avail-able, including HID lamps to 100W. Integral ballast and junction box further add to the series' reliability.

    ConstructionMaterial: Heavy wall cast bronze body and door.

    Finish: Raw bronze.

    OpticsReflector (non-reflectorized lamps): High-purity anodized specular or semi-specular ma-terials in various distributions provide maximum perfor-mance and uniformity. Lamps or reflectors are adjustable.

    Lens: Tempered clear flat borosilicate glass.

    ElectricalConduit entry: Two 1/2" or 3/4" NPT entries available, bottom or side.

    Ballast: Integrally mounted ballast, rated for low starting temperatures.

    ListingsU.L., C.U.L., IP67.

    Example: 6700 B 70CMT6 MVOLT NSP FLC 34B ISS GEB LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    13-3/4(34.9)

    10-1/2(26.7)

    9-1/4(23.5)

    1/4(0.6)

    18-1/8(46.0)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Incandescent models available with 120V only.2 Fluorescent models available with 347V or MVOLT (120-277V) only.3 Standard on fluorescent lamps and metal halide lamps with GEB ballasts.4 NSP only available with T4 or T6 lamps.5 Not available with T6 lamps, FL only available with PAR lamps.6 ISS not available with WWD distribution or P38 lamp type.7 Only available with wall wash distribution (WWD).8 Accessories are mutually exclusive. Choose one.9 RG not available with CLC or CLF lenses.10 SF only is available with 120V, 277V or 347V on HID only.11 DF only is available with 208V or 240V on HID only.12 Electronic ballasts only are available with metal halide lamps and MVOLT voltage.13 Color filter available to 100W max.14 ITB only available with NSP and MFL.15 See page 645 for visual representation.

    Sealed In-Grade

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com654

    IN-G

    RADE

    Series Lamp type Voltage Distribution Lens Mounting Conduit entry

    WD9100 Wet-dry in-grade

    Incandescent1

    P38100I PAR38, mediumP38150I PAR38, mediumP38250I PAR38, mediumQuartz3

    100Q T4, MC150Q T4, MC

    120 SP Spot1

    NFL Narrow flood2

    MFL Medium floodFL Flood1, 3

    WFL Wide flood4

    WWD Wall wash distribution5

    FLC Flat lens clearFLC5 Flat lens clear, 5° axial spreadFLC10 Flat lens clear, 10° tiltFLC30 Flat lens clear, 30° spreadFLF Flat lens frostedFLCAS Flat lens clear, anti-slip

    NM Niche mount6

    BM Base mount734B 3/4" NPT bottom12B 1/2" NPT bottom

    Options Cord set length Lamped

    IHL Internal honeycomb louverMSR Modular support ringSTR Stainless steel trim ring, round

    CSL_ 10'-120' of cord available in 5' increments LP Lamp installed

    WD9100 Intended UseThe WD9100 Series wet/dry up lights represent the state-of-the-art in flush up light construction. These multi-purpose modular units are designed for mounting in areas that are prone to being submerged in water.

    ConstructionDoor material: Cast bronze door with rock guard. Door locks the lamp housing into the rough-in section with a single tamperproof stain-less fastener.

    Rough-in section: Injection- molded ABS, U.V. stabilized, impact- and corrosion-resistant for use in all types of environments.

    Lamp module housing: Stain-less steel, sealed and purged of all moisture. Integral cord set attached. Cord entrance has a brass water-tight seal and is epoxy encapsulated. Thermally protected.

    Cord: NM – Minimum of 35' of 16-3 STWA , submersible cord for connection to a remote junction box (sold

    separately). BM – Minimum of 10' of 16-3 STWA submers-ible cord. Bronze junction box included. Cord length must be specified.

    OpticsActive lenses may be used with PAR lamps to modify the distributions.

    ElectricalLamp type: T-4 mini-can lamps to 150W. PAR-38 lamps to 250W. Lamps included.

    Conduit entry: 1/2" and 3/4" NPT bottom openings

    are available in the cast bronze integral junction box. Suitable for through-branch wiring. Junction box has 24 cubic inches of volume.

    ListingsU.L.

    Example: WD9100 P38100I 120 SP FLC NM 34B IHL CSL30 LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    12(30.5)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    12(30.5)

    11(27.9)

    Niche Mount

    12(30.5)

    11(27.9)

    Base Mount

    Notes1 PAR38 lamps are available only with SP or FL distributions; lens op-

    tions available for modifying PAR38 distributions.2 NFL distribution requires a FLC30 lens.3 FL distribution is not available with 100Q or 150Q.4 WFL distribution requires a FLF lens.5 WWD distribution requires a FLC5 lens.6 NM mounting does not come with an underwater junction box.7 BM mounting comes with an underwater junction box.

    Wet-Dry In-Grade

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    655www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADETechnical Information

    Notes1 Per Ceramic Tile Institute: Coefficient of

    friction values greater than 0.6 are considered slip resistant. Coefficient of friction values between 0.50 to 0.60 are conditionally slip resistant. Coefficient of friction values less than 0.50 are questionable.

    2 Test performed by: SGS U.S. Testing Company Inc. Tested in accordance with ISO/ICE 17025.

    3 Test performed by: Spec Testing, Inc. Tested in accordance with ISO/ICE 17025.

    The M9000 Series offers reduced lens surface tem-peratures through the use of thermal isolation and patented convective cooling technologies. As with the use of all luminaires in pedestrian areas, Hydrel rec-ommends that proper care be taken in the selection of luminaire location, lamp wattage and distribution in order to minimize pedestrian risk.

    M9400 LENS SURFACE TEMPERATURE2

    20W T4 MH

    35W T6 MH

    70W T6 MH

    75W MR16

    70W PAR30 MR16

    70W PAR30 INCAN

    NSP MFL NSP MFL NSP MFL NFL SP MFLSINGLE LENS 69°C 66°C 82°C 89°C 117°C 119°C 107°C 120°C 107°CDOUBLE LENS 49°C 46°C 54°C 53°C 75°C 73°C 70°C 82°C 90°C% DECREASE 28% 30% 34% 40% 36% 39% 35% 32% 16%

    SLIP RESISTANCE AND LOAD RATING

    M9400 M9700 M9800

    MAXIMUM LOAD RATINGPeak compression force of 7,700 lbs. (single lens) or 2,550 lbs. (double lens). LENS STATIC COEFFICIENT of FRICTIONM9400 Anti-Slip Lens (FLCAS): Dry = 0.76; Wet = 0.10M9400 Slip Resistant Lens (FLSR): Dry = 0.66; Wet = 0.67

    MAXIMUM LOAD RATINGPeak compression force of 3,750 lbs. (single lens) or 3,200 lbs. (double lens). LENS STATIC COEFFICIENT of FRICTIONM9700 Anti-Slip Lens (FLCAS): Dry = 0.76; Wet = 0.10M9700 Slip Resistant Lens (FLSR): Dry = 0.66; Wet = 0.67

    MAXIMUM LOAD RATINGPeak compression force of 3,950 lbs. (double lens). LENS STATIC COEFFICIENT of FRICTIONM9800 Anti-Slip Lens (FLCAS): Dry = 0.76; Wet = 0.10M9800 Slip Resistant Lens (FLSR): Dry = 0.66; Wet = 0.67

    SLIP RESISTANCE AND LOAD RATING

    PDX4 PDX7 PDX10

    MAXIMUM LOAD RATINGPeak compression force of 2,048 lbs.LENS COEFFICIENT OF FRICTION1PDX4 Anti-Slip Lens (FLCAS): Dry = 0.78; Wet = 0.30PDX4 Slip Resistant Lens (FLSR): Dry = 0.68; Wet = 0.59

    MAXIMUM LOAD RATINGPeak compression force of 2,847 lbs. LENS COEFFICIENT OF FRICTION1PDX7 Anti-Slip Lens (FLCAS): Dry = 0.63; Wet = 0.20PDX7 Slip Resistant Lens (FLSR): Dry = 0.81; Wet = 0.57

    MAXIMUM LOAD RATINGPeak Compression Force of 4,944 lbs.LENS COEFFICIENT OF FRICTION1PDX10 Anti-Slip Lens (FLCAS): Dry = 0.63; Wet = 0.20PDX10 Slip Resistant Lens (FLSR): Dry = 0.81; Wet = 0.57

    M9700 LENS SURFACE TEMPERATURE2

    100W E17 MH 150W T6 MH 150W E17 MH 32 W TRT 70W T6 MH 100W PAR38 MH 250W PAR38 INCANSP NFL WFL SP NSP MFL SP MFL WFL SP MFL SP MFL WFL SP FL

    SINGLE LENS 114°C 94°C 112°C 119°C 129°C 153°C 107°C 120°C 107°C 69°C 68°C 89°C 104°C 98°C 110°C NADOUBLE LENS 70°C 85°C 75°C 73°C 93°C 139°C 70°C 82°C 90°C 43°C 44°C 55°C 97°C 65°C 70°C 89°C% DECREASE 38% 10% 33% 38% 28% 39% 35% 32% 16% 38% 35% 38% 7% 34% 36% NA

    M9800 LENS SURFACE TEMPERATURE2

    250W E28 MH 400W E37 MH

    SP MFL SP SP w/ ISS MFL

    DOUBLE LENS 49°C 46°C 54°C 53°C 75°C

    PDX4 LENS SURFACE TEMPERATURE3

    20W MR16 35W MR16 50W MR16 20W MR11 35W MR11 9W LEDSP NSP FL SP NSP FL SP NSP FL NFL SP SP MFL

    PDX4 LENS 79.5°C 77.5°C 81°C 122.8°C 119°C 123°C 134°C 131°C 148°C 87°C 113°C 33°C 35°C

    PDX7 LENS SURFACE TEMPERATURE3

    20W T4 MH 35W T4 MH 70W T4 MH 36 W T6 MH 70W T6 MH 70W PAR30 MH 70W PAR30 INCAN 75W MR16NSP SP MFL NSP SP MFL NSP SP MFL NSP SP MFL NSP SP MFL SP MFL MFL

    PDX7 LENS 70°C 75°C 71°C 95°C 112°C 94°C 133°C 152°C 125°C 95°C 90°C 92°C 129°C 123°C 119°C 125°C 118°C 106°CPDX7CL LENS 43°C 44°C 44°C 53°C 55°C 57°C 73°C 69°C 66°C 52°C 47.8°C 50°C 63°C 62°C 67°C 62°C 68°C 53°C% DECREASE 39% 42% 38% 44% 51% 39% 45% 55% 47% 45% 47% 46% 51% 50% 44% 50% 42% 50%

    LENSLoad Ratings, Slip Resistance and Lens Temperatures

    PDX10 LENS SURFACE TEMPERATURE3

    70W T6 MH

    150W T6 MH 100W E17 MH 150W E17 MH 100W PAR38

    MH

    150W PAR38 INCAN

    150W E17 HPS 42W TRT FLUOR

    SP NFL FL SP NFL FL SP NFL FL SP NFL FL MFL MFL SP NFL FL SP NFL FL PDX10 LENS 79°C 83°C 86°C 99°C 105°C 108°C 95°C 115°C 114°C 115°C 148°C 143°C 98°C 96°C 113°C 138°C 139°C 70°C 71°C 68°C

    PDX10CL LENS 51°C 55°C 55°C 60°C 77°C 72°C 60°C 76°C 75°C 68°C 88°C 92°C 65°C 69°C 75°C 75°C 83°C 43°C 46°C 43°C

    % DECREASE 35% 33% 36% 39% 27% 33% 37% 34% 34% 41% 40% 36% 34% 28% 34% 46% 40% 39% 35% 37%

    The Paradox™ Architectural In-grade Cool Lens model (PDX7CL & PDX10CL) utilizes a combination brass top ring, heat sink, and reflec-tive secondary IR lens filter to reduce heat by 30% when necessary. As with the use of all luminaires in pedestrian areas, Hydrel recommends that the proper care be taken in the selection of luminaire location, lamp wattage and distribution, in order to minimize pedestrian risk.

    M9000 Series

    PDX Series

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com656

    IN-G

    RADE

    Series Material Lamp type Voltage Distribution4 Conduit entry Grill Options Lamped Finish6

    9310 A AluminumB Bronze

    Low voltageM20M35M50IncandescentP2035IP2050I

    Ceramic metal halide20CMT41

    35CMT41,7

    P2035CM1,7

    122

    120208220240277347MVOLT3

    NSP Narrow spotSP SpotNFL Narrow

    floodFL FloodMFL Medium

    floodWFL Wide flood

    12B 1/2" NPT bottom

    34B 3/4" NPT bottom8

    LC Lexan cover

    BallastGEB Electronic

    ballast5

    LP Lamp installed

    BL BlackBZ BronzeDDB Dark bronzeDNA Natural

    aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde

    greenWH WhiteCF Custom

    9310 Intended UseThe 9310 Series is designed for flush mounting in plant-ers and open lawn areas.

    ConstructionGrill: Cast aluminum painted or cast bronze natural finish. Well: Thick wall A.B.S. pipe.

    Lamp housing: Cast alumi-num or bronze body with fins for heat dissipation.

    ElectricalLamp type: Incandescent – PAR20, 50W max. Low volt-age – MR16, 50W max. HID – PAR20 HID, T4, 35W max.

    Conduit entry: Interconnect-ing conduit shall be 1/2" galvanized pipe, with brass cord seal.

    ListingsU.L., CSA.

    Example: 9310 B M50 120 NSP 34B LC LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    Notes1 Requires GEB ballast option.2 Transformer sold separately.3 MVOLT is standard on all metal halide lamps.4 Not all distributions available on all lamp types.5 Electronic ballasts are only available with metal

    halide lamps and MVOLT voltage.6 Finish available on aluminum fixtures only.7 T4 lamps only available with SP and MFL distribution.8 Default conduit entry.

    9310 Incandescent, Low Voltage (No Transformer)

    9310 HID, Low Voltage (With Transformer)

    10(25.4)

    20(50.8)

    7 Grill (17.8)

    7 Grill (17.8)

    7 (17.8)4-1/2(11.4)

    7 (17.8)4-1/2(11.4)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Well Lights

    ORDERING INFORMATION

    Visit www.hydrel.com for color changing LED specifications.

    PRODUCT INFORMATION

  • HYDREL

    657www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series Material Lamp type Voltage Distribution6 Lens Conduit entry

    93309335

    A Aluminum2

    B BronzeLow voltageM20M75P3636ILVP3650ILVIncandescent1

    P2050IP3050IP3075I

    Ceramic metal halide100CMP2035CMP3035CMP3070CMMetal halide50M70M100M

    High pressure sodium50S70S100S

    123

    1202084

    240277347MVOLT5

    NSP Narrow spot12

    SP SpotMFL Medium floodNFL Narrow floodFL FloodWFL Wide flood12

    CLC Convex lens clear

    CLF Convex lens frosted

    34B 3/4" NPT bottom

    Grill Options Lamped Finish10

    DEL Directional eggcrate louver (square)2

    FEL Full eggcrate louver (square)2

    DL Directional louver (round)CPC Clear polycarbonate (round)2

    Internal accessoriesASR Aim set ring2

    IHL Internal honeycomb louver11

    FusingSF Single fuse7

    DF Double fuse8

    BallastGEB Electronic ballast2

    LP Lamp installed BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    9330 9335

    Intended UseThe 9330 Series is designed for flush mounting in planter, tree grates or open lawn areas. The 9335 Series is designed for mounting in standard Neenah tree grates.

    ConstructionGrill: Cast aluminum or bronze; locks to well with two set screws. Full eggcrate louver or directional eggcrate louver square grills and directional louver or clear

    polycarbonate cover round grills are available. Eggcrate directional louvers provide 30° cut-off.

    Lamp module housing: Stainless steel, sealed and purged of all moisture to 100°F (38°C) and mounted integral with grill. Angular adjustment up to 15°. Electri-cal access to lamp module is done through submersible rated connector. Thermally protected. Lamp included.

    Well: Thick wall polypropyl-ene pipe.

    OpticsLens: Tempered glass lens. Convex lens clear (CLC) is standard. Convex lens frosted (CLF) also available.

    ElectricalPower module: Sealed unit encapsulated in an engi-neered composite resin to eliminate all water entry.

    Conduit entry: Two 3/4" NPT openings in the bottom of the junction box 25 cubic inches of volume suitable for through-branch wiring. Fix-ture/junction box connecting conduit is 1/2" galvanized pipe with brass cord seal.

    ListingsU.L., CSA, IP67.

    Example: 9330 B P3070CM MVOLT SP CLC 34B DL ASR GEB LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    18-1/2(47.0)

    8-1/4(21.0)

    8-3/4(22.2)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    9330 HID w/ASR

    18(45.7)

    8-1/4(21.0)

    8-3/4(22.2)

    9330 Incandescent

    Clear Polycarbonate (CPC)

    Full EggcrateLouver (FEL)

    Directional EggcrateLouver (DEL)

    Directional Louver (DL)

    9-1/2(24.1)

    9-1/2(24.1)

    9-1/2(24.1)

    9-1/2(24.1)

    Notes1 Incandescent models available with 120V only.2 Not available with 9335.3 Transformer sold separately.4 208V not available with low-voltage fixtures.5 Only available with GEB option.6 Not all distributions available with all lamp types. Check lamp manufacturers specification.7 SF available with 120V, 277V or 347V with HID only.8 DF available with 208V, 220V or 240V with HID only.9 Electronic ballasts are only available with metal halide lamps and MVOLT voltage.10 Finish available on aluminum fixtures only.11 Not available with MH, HPS or P30I WFL.12 WFL and NSP are only available with incandescent, PAR and MR16 lamps.

    Well Lights

    1/2(1.3)

    20(50.8)

    20(50.8)

    10-3/8(27.0)

    10-3/8(27.0)

    10-3/8(27.0)

    10-1/2(26.7)

    10-1/2(26.7)

    9335 HID 9335 Incandescent

    ORDERING INFORMATION

    Visit www.hydrel.com for color changing LED specifications.

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com658

    IN-G

    RADE

    Series Material Lamp type Voltage Distribution Lens Conduit entry

    9350 A AluminumB Bronze

    Quartz1

    100Q150Q250QIncandescent1

    P38100IP38150I

    Ceramic metal halide70CM100CM150CMP3870CMMetal halide70M100MP38100M

    150MP38150MHigh pressure sodium70S100S150S

    120208240277347MVOLT2

    SP SpotFL Flood

    CLC Convex lens clear3

    CLF Convex lens frosted34B 3/4" NPT bottom

    Grill Options Lamped Finish8

    DEL Directional eggcrate louver (square)FEL Full eggcrate louver (square)DL Directional louver (round)CPC Clear polycarbonate (round) 4

    Internal accessoriesIJB Internal junction boxASR Aim set ringIHL Internal honeycomb louverFusingSF Single fuse5

    DF Double fuse6

    BallastGEB Electronic ballast2, 7

    LP Lamp installed BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    9350 Intended UseUplighting of trees, shrubs, terraces or walls from a flat lawn area. The units are completely weatherproof, designed for installation in damp areas.

    ConstructionWell: Thick wall polypropyl-ene pipe for higher wattages.

    Grill: Cast aluminum or bronze. Locks to well with two set screws. Full eggcrate louver or directional eggcrate louver square grills and directional louver or clear

    polycarbonate cover round grills are available. Eggcrate directional louvers provide 30° cut-off.

    Lamp module housing: Stainless steel, sealed and purged of all moisture to 100°F (38°C) and mounted integral with grill. Angular adjustment up to 15°. Electri-cal access to lamp module is done through submersible rated connector.

    Thermally protected. Lamp included.

    OpticsLens: Tempered glass lens. Convex lens clear (CLC) is standard. Convex lens frosted (CLF) also available.

    ElectricalPower module: Sealed unit encapsulated in an engineered composite resin to eliminate all water entry. High power factor ballast.

    Conduit entry/junction box: Two 3/4" NPT. 25 cubic inches of volume suitable for through-branch wiring. Fixture/J-box connecting

    conduit is 1/2" galvanized pipe with brass cord seal. IJB (internal junction boxes) also are available.

    ListingsU.L., C.E., CSA, IP67, NEMKO.

    Example: 9350 A 100M 120 FL CLC 34B DEL ASR LP TVG

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    20-1/2(52.1)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Incandescent10

    (25.4)10-1/2(26.7)

    20(50.8)

    HID

    11-1/2(29.2)

    Clear PolycarbonateCover (CPC)

    Full EggcrateLouver (FEL)

    Directional EggcrateLouver (DEL)

    Directional Louver (DL)

    11-1/2(29.2)

    11-1/2(29.2)

    11-1/2(29.2)

    Notes1 Only available in 120V.2 MVOLT is standard if GEB is selected on metal halide lamps.3 CLC is the default if lens option is not chosen.4 100W max. for all lamp types.5 SF available with 120V, 277V or 347V only.6 DF available with 208V or 240V only.7 Electronic ballasts only are available with metal halide lamps.8 Finish available on aluminum fixture only.

    Well Lights

    Visit www.hydrel.com for monochromtic LED specifications.

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    659www.hydrel.com | 1-800-750-9773PSG10

    IN-GRADE

    Series Orientation Material Lamp type LED color

    9360DO Drive-overcapacity

    UP Flange upDN Flange down

    B Bronze LED10

    12LED 12WLow voltageM50 MR16, GX5.3M75 MR16, GX5.3P3650ILV PAR36, screw terminalP3675ILV PAR36, screw terminal

    Incandescent1

    P2050I PAR20, mediumP3050I PAR30, mediumP3075I PAR30, medium100Q T4, mini-canFluorescent8

    18TRT Triple tube, GX24q226TRT Triple tube, GX24q332TRT Triple tube, GX24q3

    MH20CMT4 T4, G8.52

    35CMT4 T4, G8.52

    35CMT6 T6, G129

    70CMT4 T4, G8.52

    70CMT6 T6, G129

    P2035CM PAR20, mediumP3035CM PAR30, mediumP3070CM PAR30, medium

    CLW Cool whiteCLWHO Cool white - high outputWMW Warm whiteAMB AmberBLU BlueCYN CyanGRN GreenRED RedRBL Royal blue

    Voltage Distribution Lens Conduit entry Options11 Lamped

    123

    120208220240277347MVOLT4

    NSP Narrow spot11

    SP SpotNFL Narrow flood11

    MFL Medium floodFL Flood11

    WFL Wide floodWWD Wall wash7,11

    LSD Linear Spread12

    FLC Flat lens clear 34B 3/4" NPT bottom Fusing5

    SF Single fuseDF Double fuseBallastGEB Electronic ballast6

    LP Lamp installed

    9360DODrive-Over Flush-Mounted Uplight

    Intended UseHydrel's Model 9360DO, is a bronze well light, incorporat-ing some of the internal components of our M9400 Series. This fixture features drive-over capacities, capable of supporting a wide variety of vehicle types and loads.

    The soils engineer or pavement designer must properly design this fix-ture into the supporting soil, subbase and finish-ing surface. A properly de-signed pavement section

    could support the fixture for vertical and lateral loads up through AASHTO HS20 (20-ton truck; 16000 Ibs. per wheel load @ 15 miles per hour). The smaller fixture footprint allows for placement in tight areas.

    ConstructionRough-in section: Cast bronze frame with stainless steel well.

    Lamp module: Stainless steel, sealed and purged of all moisture to 100°F. Electrical access to lamp module is done through

    submersible rated connec-tor. Thermally protected.

    OpticsLens: Tempered clear flat borosilicate glass.

    ElectricalPower module: Sealed unit encapsulated in an engi-neered composite resin to eliminate all water entry.

    LED driver is encapsulated in a custom-designed heat-dissipating epoxy resin that also eliminates all moisture intrusion. Module is provided

    with submersible rated cord leads for connection to integral junction box and lamp module.

    Conduit entry: Bottom open-ings are available in the cast bronze junction box. Suitable for through-branch wiring.

    Example: 9360DO DN B 70CMT6 120 NSP FLC 34B LP

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    Flange UpFlange Down

    16-1441.3)

    16-1441.3)

    8-3/8(21.3)

    11(27.9)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Notes1 Incandescent models available with 120V only.2 Lamps available with GEB electronic MVOLT (120V-277V) ballast only.3 Available for low-voltage lamps only. Remote 12V power supply required.4 MVOLT is standard on all fluorescent lamps and metal halide lamps with GEB

    ballast option.5 SF only valid with 120V, 277V or 347V. DF only valid with 208V, 220V, or 240V.6 Only valid with metal halide lamps.7 WWD only valid with T4 lamps and fluorescent lamps.8 Only available with WWD, ASY or MFL distributions.9 Only available with NSP or MFL distributions.10 Only available with MVOLT.11 Not available with LED.12 Only valid with LED.

    Well Lights

    LED

    H

    Flange Down Flange Up

    H

    8-3/8(21.3)

    11(27.9)

    Low Voltage/ Incandescent Fluorescent HID

    Height: 16-1/4 (41.3) 19 (48.3) 22-1/2 (57.2)

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com660

    FLOO

    D

    Series Lamp type Voltage Distribution Mounting Mounting accessories

    7000 Incandescent1

    100Q T4, MCFluorescent2

    26TRT GX24Q-332TRT GX24Q-342TRT GX24Q-3

    Metal halide50M E17, medium70M E17, mediumCeramic metal halide70CM E17, medium35CMT6 T6, G1270CMT6 T6, G12

    High pressure sodium35S E17, medium1

    50S E17, medium70S E17, medium

    120208240277347120/277MVOLT2

    TB

    TSP Tight spot3

    NHSP Narrow horizontal spot3

    MFL Medium fl ood3

    FL Flood4

    KM Knuckle mountYM Yoke mount

    See page 664.

    Options Lamped Finish

    Internal accessories8

    ISS Internal source shield5

    IHL Internal honeycomb louver6, 7

    CFAMB Color fi lter amber7

    CFRED Color fi lter red7

    CFBLU Color fi lter blue7

    CFGRN Color fi lter green7

    External accessories8

    BD Barn doorsGS Glare shield

    LPI Lamp included BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    7000 Intended UseThe 7000 Series fl oodlight is a compact, high-performance outdoor fi xture used for fa-cade and landscape lighting.

    ConstructionMaterial: Die-cast aluminum housing and door.

    Finish: Polyester powder coated in a range of textured or semi-matte fi nishes.

    Fasteners: Stainless steel.

    Weight: 20 lbs.

    EPA: 0.64.

    OpticsLens: Flat tempered glass.

    Refl ector: High-purity anod-ized specular, semi-specular or patterned lighting sheet in various confi gurations de-signed to provide maximum performance and uniformity.

    ElectricalLamp: Incandescent – T4, mini-can to 100W. Fluores-cent – TRT triple-tube lamps to 42W. HID – T6, G12 to 70W; E17 medium-base to 70W.

    Note: All lamps must be rated for "Universal Burning Position" because fi xture tilt changes lamp orientation.

    Socket – Incandescent – Mini-can screw base. Fluorescent – 4-pin, GX24Q base. HID – G-12, medium, or E27 base pulse-rated 4KV.

    Electrical components: Inte-grally mounted ballasts rated for low temperatures.

    ListingsU.L., C.U.L., IP65, suitable for wet locations.

    Example: 7000 70M 120 FL YM SMSA18 BD LPI BL

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    6(15.2)

    11-3/4(29.8)

    5-3/4(14.6)

    Drawings are for dimensional detail only and may not represent actual mechanical confi guration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Knuckle Mount

    8-1/4(21.0)

    11-3/4(29.8)

    13-7/8(35.2)

    Yoke MountNotes1 Available in 120V only.2 MVOLT is the standard voltage for fl uorescent lamps.3 Available with T6 and T4 lamps only.4 Available with E17 and TRT lamps only.5 Available with TSP and MFL distributions only.6 Available with FL distribution only.7 Not available with NHSP.8 Accessories are mutually exclusive. Choose one. *Mounting not included.

    Floodlighting

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    661www.hydrel.com | 1-800-750-9773PSG10

    FLOOD

    Series Lamp type Voltage Distribution Mounting Mounting accessories

    7100 Incandescent250Q T4, MC300Q T3, RSC400Q T3, RSC500Q T3, RSCMetal halide70M E17, medium100M E17, medium150M E17, medium

    Ceramic metal halide70CM E17, medium70CMT6 T6, G12100CM E17, medium150CM E17, medium150CMT6 T6, G1270CMTD T7, RSC150CMTD T7, RSC

    High pressure sodium50S E17, medium70S E17, medium100S E17, medium150S E17, medium

    120208220240277347120/277TB

    NSP Narrow spot1

    NHSP Narrow horizontal spot2

    SP SpotHSP Horizontal spotHFL Horizontal flood2

    VFL Vertical floodWFL Wide flood

    KM Knuckle mountYM Yoke mount

    See page 664.

    Options Lamped Finish

    Internal accessoriesISS Internal source shield3

    CFAMB Color filter amberCFRED Color filter redCFBLU Color filter blueCFGRN Color filter green

    External accessories4

    BD Barn doorsGS Glare shield5

    LC Polycarbonate cover5

    FusingSF Single fuse6

    DF Double fuse7

    Re-strikeQRS Quartz emergency re-strike ballast8

    QRSTD Quartz emergency re-strike time delay8

    Photo controlPE Photo eye

    LPI Lamp included BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    7100Intended UseThe 7100 Series floodlight is a compact, high-performance outdoor fixture used for fa-cade and landscape lighting.

    ConstructionMaterial: Die-cast aluminum housing and door.

    Finish: Polyester powder coated in a range of textured or semi-matte finishes.

    Fasteners: Stainless steel.

    Weight: 37 lbs.

    EPA: 1.27.

    OpticsReflector: High-purity anod-ized specular, semi-specular, patterned lighting sheet in various configurations de-signed to provide maximum performance and uniformity.

    Lens: Flat tempered glass standard.

    ElectricalLamp: Incandescent – T3, RSC quartz to 500W; T4, mini-can to 250W. HID – T6, G12 to 150W, E17 medium-base to 150W; elliptical, E27 to 150W.

    Note: All lamps must be rated for "Universal Burning Position" because fixture tilt changes lamp orientation.

    Socket: Incandescent – Recessed single contact (RSC), mini-can screw base. HID – G12, medium or E27 base pulse-rated 4KV.

    Electrical components: Inte-grally mounted ballasts rated for low starting temp.

    InstallationMounting: Knuckle or yoke mounted (180° vertical,

    360° rotation); fixed mounted for ceiling or wall. Knuckle mount – Die-cast aluminum with 3/4" NPT galvanized nipple standard. Yoke mount – Aluminum with 10' of 18-3 STW flexible cord polymer. Yoke mount caps have black finish.

    ListingsU.L., C.U.L., IP65, suitable for wet locations.

    Example: 7100 150M 120 VFL KM WMSA BD SF LPI BL

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    15-3/4(40.0)

    13-1/4(33.7)

    18-1/2(47.0)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Knuckle Mount

    15-3/4(40.0)

    6-3/4(17.1)

    9-1/4(23.5)

    6-3/4(17.1)

    16-1/2(41.9)

    Yoke Mount

    Notes1 Available with 70CMT6, 150CMT6 and 250Q lamps only.2 Not available with RSC base lamps.3 Not available with VFL or WFL distributions.4 Accessories are mutually exclusive. Choose one.5 Not available with CM mounting.6 Available with 120V, 277V or 347 HID only.7 Available with 208V, 220V or 240V HID only.8 Not available with NSP, WFL and HSP distribution.

    Floodlighting

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDR

    EL

    PSG101-800-750-9773 | www.hydrel.com662

    FLOO

    D

    Series Lamp type Voltage Distribution Mounting Mounting accessories Options

    7200 Metal halide1

    200M2, 11

    250M320M12

    350M2, 12

    400MHigh pressure sodium250S400S

    120208240277347120/277TB

    NHSP Narrow horizontal spotSP SpotHSP Horizontal spotHFL Horizontal floodVFL Vertical floodWFL Wide flood

    KM Knuckle mountYM Yoke mount

    See page 664. Internal accessoriesISS Internal source shield3

    CFAMB Color filter amberCFRED Color filter redCFBLU Color filter blueCFGRN Color filter greenExternal accessories4

    BD Barn doors

    GS Glare shieldLC Polycarbonate coverEGL Ext. grid louver5

    FusingSF Single fuse6

    DF Double fuse7

    ReceptaclePER Photocell receptacle8

    Options (continued) Lamped Finish

    BallastSCWA Super CWA pulse start10

    Re-strikeQRS Quartz emergency re-strike ballast9

    LPI Lamp includedLPIH Lamp included (horizontal burn)12

    LPIV Lamp included (vertical burn)11, 12

    BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand

    STG Steel grayTVG Terra verde greenWH WhiteCF Custom

    7200400W max.

    Intended UseThe 7200 Series floodlight is a high-performance fixture used for facade and area lighting.

    ConstructionMaterial: Die-cast aluminum housing and door.

    Finish: Polyester powder coated in a range of textured semi-matte finishes.

    Fasteners: Stainless steel.

    Weight: 50 lbs.

    EPA: 3.00.

    OpticsReflectors: High-purity anod-ized specular, semi-specular, or patterned lighting sheet in various configurations designed to provide optimum optical performance. Reflec-tors are interchangeable using four screws and quick-release electrical connectors (with the exception of spot reflectors). Reflectors include both segmented and hydroformed types to provide maximum performance and uniformity.

    Lens: Flat tempered glass.

    ElectricalLamp: HID to 400W.

    Socket: Porcelain mogul base rated 5KV.

    Electrical components: Inte-grally mounted ballasts rated for low temperatures.

    InstallationMounting: Knuckle or yoke mounted (180° vertical, 360° rotation) on pole, stanchion, wall or tenons.

    ListingsU.L., C.U.L., IP65, suitable for wet locations.

    Example: 7200 400M 277 WFL KM EWM24 SCWA LPI BZ

    ADDITIONAL INFORMATION For additional product information, visit www.hydrel.com.

    23-3/8(59.4)

    21-5/8(54.3)

    14-1/2(36.7)

    10-3/8(26.4)

    Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

    Knuckle Mount

    23-3/8(59.4)

    27-1/2(69.9)

    14-1/2(36.7)

    10-3/8(26.4)

    17-5/8(44.8)

    Yoke Mount

    Notes1 Available only with SCWA ballast.2 200M and 350M are not available with SP distribution.3 Not available with WFL distribution.4 Accessories are mutually exclusive. Choose one.5 EGL accessory available in matte black finish only.6 Available with 120V, 277V or 347V HID only.7 Available with 208V, 240V or 480V HID only.8 NEMA twist-lock receptacle only; photocontrol by others.9 Not available with TB, NHSP, SP, WFL or HSP.10 Required on 200M, 250M, 320M, 350M or 400M.11 LPIV required on 200M.12 LPIH or LPIV required on 320M or 350M.

    Floodlighting

    ORDERING INFORMATION

    PRODUCT INFORMATION

  • HYDREL

    663www.hydrel.com | 1-800-750-9773PSG10

    FLOOD

    Series Lamp type Voltage Distribution Mounting Mounting accessories1 Options

    7200 750M12

    1000M1000S

    120208240277347120/277TB

    NHSP Narrow horizontal spotSP SpotHSP Horizontal spotHFL Horizontal floodVFL Vertical floodWFL Wide flood

    KM Knuckle mountYM Yoke mount

    SMB Surface mounted ballastSMBEWM SMB extended wall mountSMBPMT Pole mount tee2

    SMBSMSA SMB stanchion mountSMBSMT SMB stanchion mount tee2

    SMBTNM SMB tenon mount3

    SMBR SMB remote mount

    Internal accessoriesISS Internal source shield4

    External accessories5

    BD Barn doorsGS Glare shieldEGL Ext. grid louver6

    Options (continued) Lamped Finish

    FusingSF Single fuse7

    DF Double fuse8

    PhotocontrolPER Photocell receptacle9

    BallastSCWA Super CWA pulse-start11

    Re-strikeQRS Quartz emergency re-strike ballast10

    LPI Lamp included BL BlackBZ BronzeDDB Dark bronzeDNA Natural aluminumGN GreenGR GraySND Sand