Circuit ProtectionHYDRAULIC–MAGNETIC
SELECTOR GUIDE
http://www.carlingtech.com/hydraulic-magnetic-circuit-breakershttp://www.carlingtech.com/
www.carlingtech.com
HYDRAULIC – MAGNETIC
M-Series MS-Series H-Series A-Series
Number of Poles 1-2 1-3 1-3 1-6 (handle) 1-3 (rocker & metal toggle)
Actuator Style
solid color: angled rocker, paddle, baton, push-to-reset pushbutton, push-pull pushbuttontwo color: visi-rockerilluminated: angled rocker, flat rocker
sealed metal togglehandle rocker curved & flat
sealed metal toggle handle rocker paddle
Available Delays AC/DC: instantaneous, short, medium, hi-inrushDC: instantaneous, short & medium
AC, DC: instantaneous, ultra-short, short, medium & long
AC, DC, AC/DC: instantaneous, ultra-short, short, medium & long
AC, DC: high inrush-short, medium & long
Max Current & Voltage Ratings
0.02-15FLA@32VDC,125VAC, 1 pole15.1-25GPA@32VDC,125VAC, 1 pole0.02-15FLA@65VDC, 250VAC, 2 pole15.1-25GPA@65VDC, 250VAC, 2 pole0.02-12FLA@250VAC, 1 pole0.02-7.5GPA@50VDC, 1 pole0.02-30GPA@65VDC, 80VDC, 1 pole31-50GPA@80VDC, parallel
0.2-30A@65VDC240VAC, 120/240VAC
1-32A@65VDC, 80VDC, 250VAC
0.02-30A@277VAC, 80VDC31.0-50A@125/250VAC, 65VDC
Max Interrupting Capacity
1,000A@65VDC, 2 pole1,000A@32VDC, 1 pole1,000A@250VAC, 2 pole1,000A@125VAC, 1 pole600A@80VDC
3000A, U1@65VDC2000A, U1@240VAC2000A, U1@120/ 240VAC
3000A@65VDC1000A@80VDC1500A@250VAC
7500A@80VDC, UL only3000A@120/250VAC, UL only5000A@277VAC, with fuse backup
Auxiliary Switch Rating
[email protected]@125VAC (gold contacts)7A (res.)@28VDC4A (ind.)@28VDC0.25A@80VDC
5A@[email protected]@125VAC, 32VDC
1.0A@65VDC/0.5A@80VDC,0.1A@125VAC (gold contacts)
[email protected]@125VAC (gold contacts)[email protected]@80VDC
Available Circuits series and switch only parallel pole series and switch onlyseries, switch only, relay trip / v coil
series, shunt, relay, switchonly, series with remote shutdown, relay & shunt trip dual coil
Terminal Options.250” QC tabs8-32 screw with upturned lugs8-32, 10-32 screw (bus type)push in stud terminals
.250” QC tabs 8-32 screw & solder type
.250” QC tabs8-32 & 10-32 screw (& metric), PCB
.250” QC tabs8-32 & 10-32 screw (& metric), PCB
Mounting Method snap-in front panel threaded bushing front panel threaded inserts threaded inserts: front panel snap-in
Agency Approvals UL recognized, CSA, VDE, TUV, UL489A listed UL 1077, cULUL recognized, CSA accepted, TUV certified & CCC certified
UL, CSA, VDE, TUV (rocker),UL1500, UL489A
http://www.carlingtech.com/hm-cb-m-serieshttp://www.carlingtech.com/hm-cb-ms-serieshttp://www.carlingtech.com/hm-cb-h-serieshttp://www.carlingtech.com/hm-cb-a-serieshttp://www.carlingtech.com/hm-cb-m-serieshttp://www.carlingtech.com/hm-cb-ms-serieshttp://www.carlingtech.com/hm-cb-h-serieshttp://www.carlingtech.com/hm-cb-a-series
www.carlingtech.com
HYDRAULIC – MAGNETIC
B-Series C-Series D-Series G-Series
Number of Poles 1-6 1-6 (handle)1-3 (rocker & metal toggle)1-4 (handle)1-3 (rocker)
1-3 (UL Listed)1-4 (UL Recognized)
Actuator Style handle rockersealed metal toggle handle rocker
solid color curved rocker (1 per unit)two color visi-rocker (1 per unit)handle (1 per pole or 1 per unit)
handle
Available Delays
AC, DC, AC/DC: instantaneous, ultra-short, short, medium & long
AC, DC: high inrush-short, medium & long
AC, DC, AC/DC: instant, ultrashort, short, medium & long
AC, DC: high inrush-short, medium & long
AC, DC, AC/DC: instant, ultra-short, short, medium, long (motor loads) AC, DC, AC/DC: high inrush-short, medium, long
AC, DC: instantaneous, ultrashort, short, medium & long
AC, DC: high inrush-short, medium & long
Max Current & Voltage Ratings
0.02-30A@277VAC, 80VDC0.02-30A@125/250VAC, 65VDC
UL Listed:[email protected]@[email protected]@240VAC
UL Recognized:0.02-30A@480WYE/277VAC 2 Pole, 1Ø3 Pole, 3Ø[email protected]@250VAC, 80VDC
0.02-50A@277VAC,65VDC 0.02-30A@ 480WYE/277VAC 2 Pole 1Ø3 Pole 3Ø
UL Listed:1-50A@80VDC1-50A@125VDC1-50A@120VAC1-50A@120/240VAC1-25A@240VAC
UL Recognized:[email protected]@240VAC0.1-63A@480YVAC
Max Interrupting Capacity
7500A@80 VDC, UL only3000A@125/250VAC, UL only5000A@277VAC, with fuse backup
UL Listed:50000A@80VDC, 1 pole only10000A@120VAC5000A@125VDC/240VAC
UL Recognized:7500A@80VDC3000A@125/250VAC, UL only 5000A@250VAC listed construction 5000A@480WYE/277VAC with fuse backup
1,500A@65VDC, 250VAC, VDE only5,000A@65 VDC5,000A@480WYE/277VAC with fuse back up3,000A@125/250VAC, UL only with fuse back up
UL Listed:5000A@80VDC5000A@125VDC5000A@120VAC5000A@120/240VAC5000A@240VAC
UL Recognized:3000A@80VDC3000A@240VAC1500A@480VAC
Auxiliary Switch Rating
[email protected]@125VAC (gold contacts)[email protected]@80VDC
[email protected]@125VAC (gold contacts)0.5A@80VDC
n/a 3A@125VAC2A@30VDC
Available Circuits
series, shunt, relay, switch only, series with remote shutdown, relay & shunt trip dual coil, mid-trip with alarm switch
series, shunt, relay, switch only, series with remote shutdown, relay & shunt trip dual coil, mid-trip with alarm switch
series, switch only, series with remote shutdown series, switch only
Terminal Options .250” QC tabs, 8-32 & 10-32 screw (& metric), PCB10-32 stud, 1/4-20 stud,10-32 screw with saddle clamp, 7/16 clip & push-In
recessed wire-ready, pressure plate type screw terminals
recessed wire-ready,pressure plate typescrew terminals
Mounting Method threaded inserts: front panel snap-in threaded insertsrear mounted on DIN rail or front panel mounted
rear mounted on DIN rail
Agency Approvals UL, CSA, VDE, TUV (rocker),UL1500, UL489, UL489AUL, CSA, VDE, TUV,UL1500, UL489, UL489A UL recognized, CSA, VDE UL1077, cUL, TUV
http://www.carlingtech.com/hm-cb-b-serieshttp://www.carlingtech.com/hm-cb-c-serieshttp://www.carlingtech.com/hm-cb-d-serieshttp://www.carlingtech.com/hm-cb-g-serieshttp://www.carlingtech.com/hm-cb-b-serieshttp://www.carlingtech.com/hm-cb-c-serieshttp://www.carlingtech.com/hm-cb-d-serieshttp://www.carlingtech.com/hm-cb-g-series
HYDRAULIC – MAGNETIC
NEW
L-Series N-Series CX-Series E-Series F-Series
Number of Poles 1-3 1-2 1-2, + auxiliary switch pole 1-6 1-3
Actuator Style rocker, with or without guardflush rocker, with or without push to reset guard
handle, 1 per pole handle handle
Available Delays
AC: ultrashort, short, medium, long, short-high inrush, medium-high inrush, long-high inrush
AC: ultrashort, short, medium, long, short-high inrush, medium-high inrush, long-high inrush
DC: instant, ultrashort, short, medium & long
AC, DC, AC/DC: instant, short, medium & long AC, DC, AC/DC: high inrush-short, medium & long
AC, DC: short, medium & long
Max Current & Voltage Ratings
.1-32A@120/240VAC
.1-20A@415/240VAC, 3 pole
1-20A@240/277VAC1-30A@120/240VAC
UL Recognized 0.2-115A@600VDCUL Listed 0.2-15A@250/500VDC 0.2-50A@205/410VDC
UL Listed0.1-100A@120/240, 240, 125VDC
UL Recognized0.02-100A@277VAC, 160VDC, 1 pole0.02-100A@600VAC, 2 Pole 1Ø, 3 pole 3Ø
UL489 Listed:50-250A@125VDC100-250A@120/240VAC100-250A@277VAC100-250A@208Y/120, 3ØVAC
UL489A Listed250-700A@125VDC
Max Interrupting Capacity 5000 amps 22,000 amps
UL Listed and UL Recognizedup to 10,000 amps
UL Listed50000A@80VDC10000A@125VDC &240VAC-5KA
UL Recognized5000A@125VDC5000A@600VAC, without fuse backup10000A@600VAC,with fuse backup
50000A@125VDC10000A@120/240, 277, 208Y/120VAC
Auxiliary Switch Rating n/a n/a
20A@80VDC (GO circuit)
[email protected]@65VDC0.1A@80VDC
[email protected]@65VDC0.1A@80VDC
Available Circuits series trip series trip series tripseries, shunt,relay,switch only, serieswith remote shutdown
series & switch onlywith or without metering shunt
Terminal Options 10-32, 8-32, M5 & M4 screw screw terms10-32 or M5 screw terminals 1/4-20 or M6 threaded stud
10-32 stud, 1/4-20 stud0-32 screw, 1/4-20 screw, box wire connector
3/8-16 stud, 3/8-16 screw & box wire connector
Mounting Methodthreaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole)
threaded insert: #6-32 x .195 inches ISO M3 x 5mm
threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole)
rear or front panel rear or front panel
Agency Approvals
UL 489, cUL, TUV (EN60934-2) UL489, TUV (EN60947-2)
UL489, UL1077, TUV (EN60934-2)
UL, CSA, VDE, UL1500, UL489
cUL,TUV, UL489, UL489A
HYMAG-SG_12_2015*Manufacturer reserves the right to change product information without prior notice
60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Email: [email protected]
http://www.carlingtech.com/hm-cb-l-serieshttp://www.carlingtech.com/hm-cb-n-serieshttp://www.carlingtech.com/hm-cb-cx-serieshttp://www.carlingtech.com/hm-cb-e-serieshttp://www.carlingtech.com/hm-cb-f-serieshttp://www.carlingtech.com/hm-cb-l-serieshttp://www.carlingtech.com/hm-cb-n-serieshttp://www.carlingtech.com/hm-cb-cx-serieshttp://www.carlingtech.com/hm-cb-e-serieshttp://www.carlingtech.com/hm-cb-f-series
Circuit ProtectionGFCI / ELCI
SELECTOR GUIDE
http://www.carlingtech.com/equipment-leakage-circuit-breakershttp://www.carlingtech.com/
GFCI-SG_12_2015
PB-Series PC-Series
POLES 1-3 poles, 3rd pole switched neutral
1-poles (1 circuit breaker + 1 GFCI sensor module), 120V,2-pole (2 circuit breakers + 1 GFCI sensor module), 120/240V, or 120V with neutral break 2-pole (2 circuit breakers + 1 GFCI sensor module), 240VAC,3-pole 120/240V with neutral break (sensor module has 2 pole width)
ACTUATOR STYLE handle, rocker, flat rocker handle, rocker, flat rocker, push-to-reset
LEAKAGE CURRENT TRIP LEVEL 30mA & 6mA 30mA & 6mA
LEAKAGE CURRENT TRIP TIME
For 30mA leakage trip:≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms
For 30mA leakage trip:≤ 22.2mA, shall not trip 30mA, shall tripwithin .10 seconds, complying with UL-1053 & ABYC E11.
For 6mA leakage trip: ≤25ms
MAX CURRENT & VOLTAGE RATINGS 0.10 - 30 amps @ 120/240VAC 0.10 - 50 amps @ 120/240VAC - 240VAC
MAX INTERRUPTING CAPACITY 5,000A 5,000A
AVAILABLE CIRCUITS series trip series trip
TERMINATION.250” tabs,8-32, 10-32, M4,M5 screw with upturned lugs,8-32, 10-32, M4,M5 screw, bus type
10-32 threaded stud
MOUNTING METHOD front panel front panel
OPERATING TEMPERATURE -35° C to +65° C -35° C to +65° C
APPROVALS UL 489, UL 1077, UL 1500 CSA Approved, UL 1053, UL 1500
*Manufacturer reserves the right to change product information without prior notice
60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Web: www.carlingtech.com
http://www.carlingtech.com/equipment-cb-pb-serieshttp://www.carlingtech.com/equipment-cb-pc-serieshttp://www.carlingtech.com/equipment-cb-pb-serieshttp://www.carlingtech.com/equipment-cb-pc-series
Rocker, Toggle, Pushbutton & RotarySWITCHES & CONTROLS
SELECTOR GUIDE
http://www.carlingtech.com/rocker-switcheshttp://www.carlingtech.com/toggle-switcheshttp://www.carlingtech.com/push-button-switcheshttp://www.carlingtech.com/rotary-switcheshttp://www.carlingtech.com/switcheshttp://www.carlingtech.com/
www.carlingtech.com
FULL-SIZED ROCKERS MID-SIZED AND SMALL-SIZED ROCKERS
S-Series TIL / LTIL TIG / LTIG / LS
RR / LRR R / LRA / RSC RG / LRG
620 / 621 / 622 632 / 651
T / LTA / TG / LTG / TLG / TTG
Poles one, two one, two one one, two one, two one, two
Ratings dry circuit to 10A 28VDCdry circuit to15A 125VAC10A 250VAC
up to12A 125VAC10A 250VAC
up to20A 125VAC15A 250VAC
dry circuit to12A 125VAC10A 250VAC8A 250VAC1/2 HP 125-250VAC
up to20A 125VAC10A 250VAC
Sealed Actuator bezel-less rocker rocker, paddle rocker rocker, paddle rocker, paddle
rocker, lever, paddle, plunger, toggle (bat)
Mounting Hole Specifications
.787” x 1.575” snap-in, keyed
.830” x 1.450”[21.08mm x 36.83mm]snap-in mountscrew mount
.795” [20.2mm]round snap-in mount
.480” x 1.072”[12.19mm x 27.23mm].866” x 1.182”[22mm x 30mm]snap-in mount
.508” x .756”[12.9mm x 19.2mm]snap-in mount
.550” x 1.125”[13.97mm x 28.57mm] 1.00” x 1.125”[25.4mm x 28.57mm]snap-in mount
Termination .110 Tabs
.187 tab solder lug.250 tabs screw terms wire leads
.187 tab
solder lug.250 tabs wire leads PC terms
.187 tab solder lug wire leads PC terms
.187 tabsolder lug .250 tabs wire leads
Illumination LED incandescent, neonincandescent, neon
incandescent, neon
incandescent, LED, neon
incandescent, neon
Approvals n/a UL, CSA, VDE UL, CUL UL, CSA, VDE UL, CSA, VDE UL, CSA
*Options and approvals shown may apply to specific construction combinations only, consult factory for clarification.
SEALED SWITCHES
NEW NEW
V-Rotary ST-Series V-Series W-Series L-Series
Poles one, two one, two one, two one, two one, two
Ratingsdry circuit to15A 24VDC15A 150VAC10A 250VAC
16A 12V16A 18V15A 24V15A 125VAC10A 250VAC
dry circuit to15A 24VDC15A 150VAC10A 250VAC
dry circuit to 10A 24VDC
dry circuit to15A 125VAC10A 250VAC20A 18VDC
Sealed Actuator IP67, rotary knob IP68, bat
IP66, rocker, paddle,locking rocker
IP68 including connector, bezel-less rocker, paddle & locking rocker
IP67, rocker, paddle, locking rocker
Mounting Hole Specifications
.830” x 1.450”[21.08mm x 36.83mm]snap-in mount
.500” dia[12.7mm]bushing mount
.830” x 1.450”[21.08mm x 36.83mm]snap-in mount
.830” x 1.450”[21.08mm x 36.83mm]snap-in mount
.867” x 1.734”[22mm x 44mm]snap-in mount
Termination.250 tabs solder lug wire leads
.250 tabsscrew terms
.250 tabs solder lug wire leads
.110 tabs .187 tab .250 tabs
Illumination incandescent, LED, neon n/aincandescent, LED, neon LED incandescent, LED
Approvals pending UL, cUL pending UL, CSA, VDE n/a n/a
Manufacturer reserves the right to change product specifications without prior notice.
www.carlingtech.comhttps://www.carlingtech.com/rocker-switches-s-serieshttp://www.carlingtech.com/rocker-switches-til-tig-tih-tii-serieshttp://www.carlingtech.com/rocker-switches-rr-lrr-serieshttp://www.carlingtech.com/rocker-switches-r-serieshttp://www.carlingtech.com/rocker-switches-610-620-serieshttp://www.carlingtech.com/rocker-switches-t-serieshttps://www.carlingtech.com/rocker-switches-s-serieshttp://www.carlingtech.com/rocker-switches-til-tig-tih-tii-serieshttp://www.carlingtech.com/rocker-switches-til-tig-tih-tii-serieshttp://www.carlingtech.com/rocker-switches-rr-lrr-serieshttp://www.carlingtech.com/rocker-switches-r-serieshttp://www.carlingtech.com/rocker-switches-r-serieshttp://www.carlingtech.com/rocker-switches-610-620-serieshttp://www.carlingtech.com/rocker-switches-610-620-serieshttp://www.carlingtech.com/rocker-switches-t-serieshttp://www.carlingtech.com/rocker-switches-t-serieshttp://www.carlingtech.com/rocker-switches-v-series-rotaryhttp://www.carlingtech.com/switcheshttp://www.carlingtech.com/rocker-switches-v-series-ii-iiihttp://www.carlingtech.com/rocker-switches-w-serieshttp://www.carlingtech.com/rocker-switches-l-serieshttp://www.carlingtech.com/rocker-switches-v-series-rotaryhttp://www.carlingtech.com/switcheshttp://www.carlingtech.com/rocker-switches-v-series-ii-iiihttp://www.carlingtech.com/rocker-switches-w-serieshttp://www.carlingtech.com/rocker-switches-l-series
www.carlingtech.com
*Options and approvals shown may apply to specific construction combinations only, consult factory for clarification.
TOGGLE SWITCHES
LT-Series F / G / H / I C / D 110-Series DK / EK MAAOA / 215
Poles one, two one, two, three, four one one, two one, two one
Ratingsdry circuit to15A 125VAC10A 250VAC15A 12-28VDC
dry circuit to20A 125VAC20A 277VAC
up to20A 125VAC10A 250VAC
up to6A 125VAC/DC3A 250VAC/DC
up to20A 125VAC/DC10A 250VAC/DC
up to20A 125VAC10A 250VAC1/2HP 125-250VAC
Actuator paddle, toggle (bat) paddle, toggle (bat)paddle, toggle (bat)
toggle (bat), toggle (ball)
toggle (bat), toggle (ball) toggle (bat)
Mounting Hole Specifications
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.656” x 1.218”[16.66mm x 30.54mm]snap-in mount
Termination
.187 tabs solder lug .250 tabs screw termswire leads PC terms
.187 tabs solder lug .250 tabs screw termswire leads PC terms
solder lug.250 tabs screw terms wire leads
solder lug .250 tabs screw terms wire leads
screw terms.250 tabs screw terms wire leads
Illumination incandescent, neon n/a n/a n/a n/a n/a
Approvals n/a UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA
*Options and approvals shown may apply to specific construction combinations only, consult factory for clarification.
CONTROLS
NEW
LD Dimmer LMR Mirror LW Wiper N-Series V-Charger
Poles multi-function multi-function multi-function one one
Ratingsup to10A 12VDC5A 24VDC
up to1A 14VDC.5A 28VDC
up to8A 14VDC4A 28VDC
.4VA 28VDC 12V/24VDC
Actuator rocker, paddle joystick rocker, paddle rocker, paddle sealed spring-loaded access doors
Mounting Hole Specifications
.867” x 1.734” [22mm x 44mm]snap-in mount
.867” x 1.734” [22mm x 44mm]snap-in mount
.867” x 1.734” [22mm x 44mm]snap-in mount
.867” x 1.734” [22mm x 44mm]snap-in mount
.830” x 1.450”[21.08mm x 36.83mm] snap-in mount
Termination .250 tabs wire leads with connector .187 tabs .187 tabs .250 tabs
Illumination LED n/a LED LED LED
Approvals n/a n/a n/a n/a n/a
www.carlingtech.comhttp://www.carlingtech.com/toggle-switches-lt-serieshttp://www.carlingtech.com/toggle-switches-f-serieshttp://www.carlingtech.com/toggle-switches-c-serieshttp://www.carlingtech.com/toggle-switches-110-216-serieshttp://www.carlingtech.com/toggle-switches-dk-ek-serieshttp://www.carlingtech.com/toggle-switches-maaoa-215-serieshttp://www.carlingtech.com/toggle-switches-lt-serieshttp://www.carlingtech.com/toggle-switches-f-serieshttp://www.carlingtech.com/toggle-switches-c-serieshttp://www.carlingtech.com/toggle-switches-110-216-serieshttp://www.carlingtech.com/toggle-switches-dk-ek-serieshttp://www.carlingtech.com/toggle-switches-maaoa-215-serieshttp://www.carlingtech.com/controls-ld-serieshttp://www.carlingtech.com/controls-lmr-serieshttp://www.carlingtech.com/controls-lw-serieshttp://www.carlingtech.com/rocker-switches-n-serieshttp://www.carlingtech.com/controls-v-chargerhttp://www.carlingtech.com/controls-ld-serieshttp://www.carlingtech.com/controls-lmr-serieshttp://www.carlingtech.com/controls-lw-serieshttp://www.carlingtech.com/rocker-switches-n-serieshttp://www.carlingtech.com/controls-v-charger
SW-SG_01_2016
PUSHBUTTON
16-3P 170 / 172 P26 / P27 641 / 110 P / PP
Poles one one one one, two, three one
Ratings up to3A 125VACup to15A 125VAC10A 250VAC
dry circuit to6A 125VAC3A 277VAC
up to5A 125VAC2A 250VAC
up to20A 125VAC10A 250VAC
Mounting Hole Specifications
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
.500” dia[12.7mm]bushing mount
Termination solder lug wire leadssolder lug screw terms wire leads
.250 tabs solder lugwire leads
solder lug wire leads PC terms
.250 tabs screw terms wire leads
Approvals UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA, TUV
*Options and approvals shown may apply to specific construction combinations only, consult factory for clarification.
ROTARY
NEW
R135 700 / 800 V-Rotary
Poles one one one, two
Ratings1.5A 250VAC3A 125VAC5A 12VDC
up to3A 250VAC6A 125VAC
dry circuit to15A 24VDC20A 12VDC
Actuator round asymmetrical ergonomic
Mounting Hole Specifications
.375” dia [9.52mm]bushing mount.500” dia [12.7mm]snap-in mount
.500” dia [12.7mm]bushing mount
.830” x 1.450”[21.08mm x 36.83mm]snap-in mount
Termination wire leads.125 tabs solder lug.250 tabs
solder lug.250 tabs wire leads
Illumination n/a n/a incandescent, LED
Approvals UL, CSA UL, CSA pending
60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Email: [email protected]
http://www.carlingtech.com/pushbutton-switches-16-3p-serieshttp://www.carlingtech.com/pushbutton-switches-170-172-serieshttp://www.carlingtech.com/pushbutton-switches-p26-serieshttp://www.carlingtech.com/pushbutton-switches-641-serieshttp://www.carlingtech.com/pushbutton-switches-p-serieshttp://www.carlingtech.com/pushbutton-switches-16-3p-serieshttp://www.carlingtech.com/pushbutton-switches-170-172-serieshttp://www.carlingtech.com/pushbutton-switches-p26-serieshttp://www.carlingtech.com/pushbutton-switches-641-serieshttp://www.carlingtech.com/pushbutton-switches-p-serieshttps://www.carlingtech.com/rotary-switches-r135-serieshttps://www.carlingtech.com/rotary-switches-700-serieshttps://www.carlingtech.com/rotary-switches-V-Serieshttps://www.carlingtech.com/rotary-switches-r135-serieshttps://www.carlingtech.com/rotary-switches-700-serieshttps://www.carlingtech.com/rotary-switches-V-Seriesmailto:[email protected]
Circuit ProtectionTHERMAL
SELECTOR GUIDE
http://www.carlingtech.com/thermal-circuit-breakershttp://www.carlingtech.com/
THERMAL CIRCUIT BREAKERS
TH-SG_12_2015
*Manufacturer reserves the right to change product information without prior notice
C1005B-Series CTB-Series CMB-Series CLB-Series CMBA/CLBA-Series
Number of Poles single single single single single
Actuator Style rocker,lighted rocker rocker pushbutton pushbutton n/a
Max Current & Voltage Ratings
7 to 16A, 125-250VAC,32VDC
3 to 15A, 125-250VAC,50VDC
3 to 20A, 125-250VAC,32 VDC
3 to 60A, 125-250VAC,32 VDC
3 to 40A, 125-250VAC,32 VDC
Max Interrupting Capacity 1000A 1000A 2500A@32VDC 2500A@32VDC 2500A@32VDC
Available Circuits series trip manual resetseries tripmanual reset
series tripmanual reset
series tripmanual reset
series tripauto reset
Terminal Options .250” tab, solder lug .250” tab
.250” tab,
.250” tab with 90° bend,screw terminal,screw terminal with 90° bend
.250” tab,
.250” tab with 90° bend,screw terminal,screw terminal with 90° bend
.250” tab,
.250” tab with 90° bend
Mounting Method front panel snap-in front panel snap-in threaded bushing,front panel snap-inthreaded bushing,front panel snap-in plug-in
Operating Temperature -10°C to 65°C -10°C to 60°C -10°C to 60°C -10°C to 60°C -10°C to 60°C
Agency Approvals UL, CUL, TUV UL, CUL, VDE, CE
UL, CUL, CSA, TUV, CE,UL 1500 / ISO 8846 forignition protection / marine
UL, CUL, CSA, TUV, CE,UL 1500 / ISO 8846 forignition protection / marine
UL, CUL, TUV, UL 1500 / ISO 8846 forignition protection / marine
60 Johnson Avenue | Plainville, CT 06062 | Phone: (860) 793-9281 | Fax: (860) 793-9231 | Email: [email protected]
http://www.carlingtech.com/thermal-cb-c1005b-serieshttp://www.carlingtech.com/thermal-cb-ctb-serieshttp://www.carlingtech.com/thermal-cb-cmb-serieshttp://www.carlingtech.com/thermal-cb-clb-serieshttp://www.carlingtech.com/thermal-cmba-clba-serieshttp://www.carlingtech.com/thermal-cb-c1005b-serieshttp://www.carlingtech.com/thermal-cb-ctb-serieshttp://www.carlingtech.com/thermal-cb-cmb-serieshttp://www.carlingtech.com/thermal-cb-clb-serieshttp://www.carlingtech.com/thermal-cmba-clba-series
CB_SelectorGuideGFCI_SelectorGuideSwitch_SelectorGuideThermal_SelectorGuide