1
COPYRIGHT 2001-2002 K8CU ALL RIGHTS RESERVED 200 MegOhm 14 KV Make with 39 each 5.1Meg 1/2 W 5% resistors in series (Radioshack 900-0467) 50 MegOhm 14 KV Make with 42 each 1.2 Meg 1/2W 5% resistors in series. (Radioshack 900-0453) 2100 VAC Microwave oven diodes 14 kV 550 mA 14 kV 550 mA Lower wattage light bulbs will glow brightly and inhibit greater voltage output with the microwave oven transformer at around 8 KV out. This varies with each transformer, and is caused by the relatively high saturating current typical of this kind of transformer. To increase the output voltage without excessive current limiting, simply increase the light bulb wattage. 150-200 Watt Light Bulb 125 Watt Light Bulb 0 to 8 KV out High Voltage Breakdown Tester 120 VAC Each capacitor = .002 or higher. C1 = 2500 volt rating C2 = 5000 volt rating C3 = 7500 volt rating C4 = 5000 volt rating Either voltage source is suitable, only one is required. DANGER HIGH VOLTAGE High voltage leakage detector and metering circuit Variable high voltage DC input Output Voltage Meter 0 to 10 KV full scale. Basic meter movement is 50 uA 1N4004 Fuel oil furnace inition transformer voltage source Microwave oven transformer voltage source CAUTION: secondary center tap is connected to transformer case. Primary 120 VAC Secondary 10 KV AC Voltage quadrupler Fuel oil furnace ignition transformer Any microwave oven transformer 0 to 10 KV out Variac Adjust 120 VAC 1N4004 1N4004 Common 0 to 10 KV High voltage out to device under test Microwave oven diode Each cap is .001 at 10 KV 200K 2 Watt Bridge Rectifier 50 PIV 1 Amp Leakage Current Meter 0 to 50 uA + - - + Variac Adjust 120 VAC METER METER DRAWN BY: DATE: PAGE 5-17-2002 Bill Jones K8CU 1 of 1 C1 C3 C4 C2 C

HV-TESTER

Embed Size (px)

DESCRIPTION

High Voltage Breakdown Tester

Citation preview

Page 1: HV-TESTER

COPYRIGHT 2001-2002 K8CU ALL RIGHTS RESERVED

200 MegOhm 14 KVMake with 39 each 5.1Meg1/2 W 5% resistors in series (Radioshack 900-0467)

50 MegOhm 14 KVMake with 42 each 1.2 Meg1/2W 5% resistors in series.(Radioshack 900-0453)

2100 VAC

Microwave oven diodes14 kV 550 mA

14 kV 550 mA

Lower wattage light bulbs will glowbrightly and inhibit greater voltage output with the microwave oven transformer ataround 8 KV out. This varies witheach transformer, and is caused by therelatively high saturating current typicalof this kind of transformer. To increase theoutput voltage without excessivecurrent limiting, simply increase thelight bulb wattage.

150-200 Watt Light Bulb

125 Watt Light Bulb

0 to 8 KV out

High Voltage Breakdown Tester

120 VAC

Each capacitor =.002 or higher.

C1 = 2500 volt ratingC2 = 5000 volt ratingC3 = 7500 volt ratingC4 = 5000 volt rating

Either voltage source is suitable, only one is required.

DANGERHIGH VOLTAGE

High voltage leakage detector and metering circuit

Variable high voltage DC input

Output Voltage Meter0 to 10 KV full scale.Basic meter movement is 50 uA

1N4004

Fuel oil furnace inition transformer voltage source

Microwave oven transformer voltage source

CAUTION: secondary center tapis connected to transformer case.

Primary 120 VACSecondary 10 KV AC

Voltage quadrupler

Fuel oil furnaceignition transformer

Any microwave oven transformer

0 to 10 KV out

Variac Adjust

120 VAC

1N4004

1N4004

Common

0 to 10 KVHigh voltage out to device under test

Microwave oven diode

Each cap is .001 at 10 KV

200K 2 Watt

Bridge Rectifier50 PIV 1 Amp

Leakage Current Meter 0 to 50 uA

+

-

-

+

Variac Adjust

120 VAC

METER METER

DRAWN BY:

DATE:PAGE 5-17-2002

Bill Jones K8CU

1 of 1

C1

C3

C4

C2

C