What to Expect withYour Installation Ceiling B
LadderPAG
E3
Tools Needed
Wiring Cano
Maintenance& CleaningBlades Troubles
Downrod
Switch Housing Light Kit
Preparation
Table of Contents
PAG
E12
Congratulations on purchasing
your new Hunter ceiling fan! It will
provide comfort and performance
in your home or ofce for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
To register your fan please visit:
www.HunterFan.com/register
PAG
E4
Mounting Options
PAG
E14PAG
E16
?
?
1M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
2/17
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
What to Expect with Your Installation
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to seefan weight
Assess location
30 inchesfrom blade tip
to nearest wall
or obstruction 7 feetfrom bottom
edge of bladeto the oor
Select a downrod length
w.1 - To reduce the risk of re,
personal injury, mount fan dire
structure and/or an outlet boxfan support of 70 lbs (31.8 kg) ascrews provided with the outle
w.2 - To avoid possible electric
or servicing your fan, disconneoff the circuit breakers to the o
wall switch location. If you canbreakers in the off position, sec
warning device, such as a tag, t
w.3 -To reduce the risk of re, e
damage, use only Hunter Solid
w.4 - To reduce the risk of personblade brackets when installing th
the blades, or cleaning the fan. Din between rotating fan blades.
c.1 - All wiring must be in accordlocal electrical codes ANSI/NFPA
with wiring, use a qualied elect
c.2 - Use only Hunter replacem
Assess ceiling angle
Read and Save The
This product conforms to UL S
WARN
CAUT
Must be able tosecure the fan tobuilding structure orfan-rated outlet box
1
2
3
Standard Downrod
for ceilings 8-10 feet high
Shorter Downrodfor fans installed close to ceiling
Longer Downrodfor ceilings 10 feet or higher
2
Ceiling angles greater
than 34 will require an
Angled Mounting Kit.
See page 4 for details.
7/27/2019 Hunter manual.pdf
3/17
www.HunterFaTools Needed
Ladder
Power Drill(optional)
9/64 Drill Bit(optional)
ScrewdrPliers Wire Strippers
If mounting to a support structure, you will also need these tools.
3M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
4/17
www.HunterFa
4M0039-01 02/20/13 Hunter Fan Company
If you have an angled ceiling:
1. You will need a longer downrod (sold separately).
2. If your ceiling angle is greater than 34, you will
also need an Angled Mounting Kit (sold separately).
Guide Touches
BOTH Ceiling & Wall
S
ITUAT
ION1
Guide Touches Wall
but
NOT Ceiling
S
ITUAT
ION2
You need BOTHa Longer
Downrod &an Angled
Mounting Kit
You need ONLYa LongerDownrod
*most common
If you have a at ceiling:
Hang your fan by a standard downrod (included).
Mounting Options
Use Standard Mounting
or Low-Prole Mounting
to hang the fan from a at ceiling.
Use An
to han
vaulted
4
34O
CEILING
WALL
OPTION1
Standard
Mounting
OPTION2
Angled
Mounting
2 3
SLIDEtoward ceiling
PLACEagainst wall
1
FOLDon dotted line
34
Use the three steps below to determine if your ceiling angle i s greater than 34
www.HunterFa
SupportStructure
AngledMountingStyle
StandardMountingStyle
SupportStructure
CeilingOutlet Box(required)
M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
5/17
www.HunterFaCeiling Bracket
OFFMake sure all four (4) bumpers
are still attached.
For angle
openin
Refer to w
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outletbox associated with the wall switch location.
If you are
call Tech
1-88
Use wood screws(included) when securingto support structure with
approved electrical outlet
box. Drill 9/64 pilot holes
in support structure to aid
in securing ceiling bracket
with hardware found in
the hardware bag.
Use machine screws(provided with outlet
box) when securing to
existing ceiling fan-rated
outlet box. Make sure
it is securely installed
and is acceptable for fan
support of 31.8 kg (70 lbs)
or less.
Turn
Powe
r
5M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
6/17
www.HunterFaCeiling Bracket (continued) Preparation www.HunterFa
DISCAR
D
KEEP!
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
Time Saver Tip:to insert gromme
the hardware
blades while you
next couple o
6M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
7/17
Downrod
S
lide
S
lid
e
1 2 3 4
78910
SoldSeparately
Included
LongerDownrodfor angledceilings orceilings 10 orhigher
ShorterDownrodfor fans installedclose to ceiling
StandardDownrodfor ceilings 8-10 high
Option1
Option
2
Option3
skip to next pag
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Steps 6-10 to reassemble with new pipe
Included
(pre-assembled)
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
7
7/27/2019 Hunter manual.pdf
8/17
KEEP!
8
3/8
CUT
&ST
RI
P
(nottos
cale)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
The wires can be cut, but
leave at least 8 extending
from the top of the downrod.
Downrod (continued)
8 3/8
Tighte
with p
HAN
If the sesecurely
KEEP!
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
8
7/27/2019 Hunter manual.pdf
9/17
9M0039-01 02/20/13 Hunter Fan Company
www.HunterFaDownrod (continued)
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
of the fan.
7/27/2019 Hunter manual.pdf
10/17
www.HunterFaWiring
FROMFAN
FROMCEILINGBRAC
KET
FROM FAN
Using an orange wire
connector from
the hardware bag,
connect the 3 grounding
wires (green, green/
yellow stripe, or bare
copper) coming from the
ceiling, downrod, and
hanging bracket.
(Grounding)
Green/Yellow
Stripe
Green/YellowStripe
White
Black
(Grounded)
Note:To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
Using the orange wire
connectors fromthe hardware bag, connect
the black wire (ungrounded)
from the ceiling to the black
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
the white wire from the fan.
Using orange wire
connectors from
the hardware bag,
connect the white wire
(grounded) from the
ceiling to the white wire
from the fan.Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
Blue
For Dual Switches
For a Single Switch
FR
OMCEILING
FROM
CEILING
Turn the splices upward and push them carefully back throug
into the outlet box. Spread the wires apart, with the groundethe outlet box and the ungrounded wires on the other sideRefer to CAUTION c.1 on pg. 2
10M0039-01 02/20/13 Hunter Fan Company
(Ungrounded)
7/27/2019 Hunter manual.pdf
11/17
www.HunterFa
11M0039-01 02/20/13 Hunter Fan Company
Canopy
Lift the canopy into place so that
the screw holes are aligned.
Position the canopy so that, when
lifted into place, the canopy ts into
the hanging bracket as shown.
ScrewHoles
Insert the two canopy screws
found in the hardware bag.
Note: Fan style m
7/27/2019 Hunter manual.pdf
12/17
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
Blades
Your blades are shielded with
is a nanotechnology coating cleaning the fan, use soft brushe
scratching. Cleaning agents ma
12
Insert grommets found in the hardware
bag into the holes in the blades, then
secure each blade to a blade iron with
screws found in the hardware bag.
Lightly attach the blade irons to the
motor with the blade iron armature
screws, then securely tighten after both
screws are attached.
Remember the screws thatyou kept after removing the
shipping blocks (page 6)? Youneed them for this step.
7/27/2019 Hunter manual.pdf
13/17
www.HunterFa
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Screw two (2) housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
Insert the third scre
the hardware bag, int
tighten all three (3
Make sure the upper switch housing
attached to the mounting plate. Fail
secure all 3 assembly screws could rhousing xture falling.
Switch Housing
13M0039-01 02/20/13 Hunter Fan Company
7/27/2019 Hunter manual.pdf
14/17
www.HunterFaLight Kit
Partially install two of the switch housing
screws found in the bag. Connect
the plugs from the upper and lower
switch housings. Make sure to line up the
colored markings on the connectors.
Align the notches in the sides of the lower
switch housing with the upper switch
housing screws. Lift the lower switch housing.
Twist the lower switch housing clockwise
to lock into place. Then thread the fan
pull chain through the hole in the light kit.
Light Kit
Install the third switch ho
Tighten all three screw
Make sure the lower switch housing is secur
the upper switch housing. Failure to properswitch housing screws could result in the lig
SwitchHousingScrew
SwitchHousingScrew
Notch
Want to install your fan without a light kit?
Go to www.HunterFan.com/FAQs and click
How do I install my fan without the light kit?
M0039-01 02/20/13 Hunter Fan Company
14
7/27/2019 Hunter manual.pdf
15/17
www.HunterFaLight Kit (continued)
See next pag
operation in
CONGRATULATIYOUREDO
See next pag
operation in
Connect the appropriate pull
chain pendant to each of the short
chains coming from the nial
and nial cap. The fan pull chain
controls the speed: from high to
off. The light pull chain controls
the light xture: on and off.
LightPullChain
Fan
PullChain
Press the globe and globe keeper ush
against the metal plate. Thread the
light pull chain through the hole in the
center of the nial cap and thread the
fan pull chain through the hole in the
side of the cap. Finally, thread only the
light pull chain through the hole in
the nial and screw the nial onto the
threaded rod.
Install a light bulb in each socket.
Finial
FinialCap
GlobeKeeper
MetalPlate
Globe
M0039-01 02/20/13 Hunter Fan Company
15
i l i
7/27/2019 Hunter manual.pdf
16/17
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
16
Maintenance & Cleaning
ONTu
rnPower
Changing the direction of air
ow - move the reverse switch
to the opposite position.
Cleaning the fa
brushes or cloth
scratching. Clean
may damage th
ReverseSwitch
Changing the bulbs - unscrew
the nial and remove it from the
threaded rod. Remove the nial cap
and unscrew the globe keeper while
supporting the globe with your other
hand. Carefully remove the globe.
Unscrew bulbs and replace with
bulbs of same type and wattage.
Reinstall the globe assembly.
Finial
FinialCap
GlobeKeeper
MetalPlate
Globe
For questions regarding removing a lcustomer service 1-888-830-1
H Fbl h i
7/27/2019 Hunter manual.pdf
17/17
www.HunterFa
M0039-01 02/20/13 Hunter Fan Company
17
Troubleshooting
Excessive wobbling
Tighte n a ll of the bla de and
blade iron screws until they
are snug.
Turn the powe r o ff, sup por t
the fan carefully, and check
that the hanger ball is
properly seated.
Use the provided balancing
kit and instructions to balance
the fan.
Noisy Operation
Tighten the blade and blade
iron screws until they are snug.
Check to see if any of the
blades are cracked. If so, replace
all of the blades.
Fan doesnt work
Make sure power switch is on.
Pull the pull chain to make sure
it is on.
Push the motor reversing switchrmly left or right to ensure that
it is engaged.
Check the circuit breaker to
ensure the power is turned on.
Make sure the blades spin freely.
Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagramon page 10.