Huawei UPS2000-A solutions

2

Challenges & trends

3

Reliable UPS Against Poor Grid

Unavoidable grid problems

Blackout of Manhattan Blackout of USA and Canada

Harsh environment condition

Lightning Poor quality of grid

A variety of loadsPoor grid Damage of electrical device Adverse environment condition

4

Efficient UPS for Energy Saving

High efficiency, low power consumption

It is estimated that the annual power consumption of the data centers all over the world is up to 40,000,000,000 kW·h.

Energy consumption of typical data center

If the efficiency of UPS is improved from 90% to 92%, the power consumption decreasing for UPS itself is about 21.7% and cost saving for data center is about 0.5 billion kW·h, reducing about 20 million tons of carbon emissions.

Business grow with low OPEX

5

Huawei UPS Solutions

25-800kVA

30-800kVA

Small

Medium

1-20kVAUPS2000-G

UPS5000-E

UPS5000-A

UPS capacity Tower RT Modular Tower

Large

1-10kVAUPS2000-A

6

Capacity 1/2/3kVA 6/10kVA Standard Version6/10kVA Professional

Version

Appearance

Input : Output 1-in : 1-out

Model Standard ; long run Standard ; long run Standard ; long run

Parallel ---- ---- Support 4 UPSs in parallel

Maintenance Bypass

---- ---- Build-in

L-L 208V ---- ---- support

UPS2000-A (1-10kVA)

7

Huawei UPS2000-A solutions

8

• LCD display

• Build-in battery

• Battery intelligent management, flexible configuration

• Integrated monitoring Platform for the whole network

UPS2000-A Core Value

• When working in online mode the efficiency is up to 96%

• High efficiency at low load rate

• Widest input voltage range

• 5kA lightning design

• Coating design and key device pin special protection Reliable

Efficient

Simple

9

• 1/2/3kVA Input voltage range: 110V to 300V

• 6/10kVA Input voltage range: 80V to 280V

Online double conversion, the wide input voltage range

Common Power Problems

Wide input voltage

EfficientReliable Simple

80V AC input 280V AC input Spike wave input Serious distortion wave input

High Adaptability to Extend Battery Life

Minimizes battery use to extend battery

lifespan.

10

125% overload for 5 minutes 150% overload for 30 seconds

supports 150% Overload

High Overload Capacity

Various Loads

• Output power factor: 0.9• Capacitive/inductive loads from

lead 0.5 to lag 0.5• High output load capacity ensuring

expansion demands in future

Supports various load

Electrical load with constant changes

High Overload Capacity Ensure Supply Quality

EfficientReliable

Reduces transfer times to bypass mode, ensuring customer equipment power supply quality.

server TV

ATM compressor

Simple

11

More than 70% of lightning accidents involve

the power supply system.

More than 90% of lightning accidents involve

computer network and communication

systems armed with UPS.

Unrecoverable hardware damage to IT equipment caused by lightning

5 kA lightning protection design by simulating actual lightning

Lightning design(Input common-mode)

HUAWEI 6 kV/5 kA

Traditional 4 kV/2 kA or none

Huawei UPS can prevent 90% of failures

caused by lightning by protecting equipment

input ports.

5 kA Lightning Protection Reducing Failure

EfficientReliable

Rocket-triggered lightening

Simple

12

To enhance reliability design, the system is safe and reliable

Coating

Coating design improves the ability to adapt to the harsh physical environment

dustproof

Preventing lateral diffusion of dust and enhancing thermal dissipation capacity

Pin protection

Special protection of vulnerable components helps reduce the failure rate and improve system reliability

√ × √ ×

EfficientReliable Simple

13

1,000 hours at 40℃

Temperature, Humidity, Bias (THB)Temperature: 40℃

Humidity: 95% for 1,000h

Temperature shocksampling test

High temperature test

-40°C to 70 ℃HALT

Highly accelerated life test

-60 to 110 ℃ ℃

5 cycles

Global Certification Test Center

Long Life Test (LLT)Temperature: 40℃

6 months

Open field

Hainan open field

Airborne hygroscopic dust , salt

spray environment

Shenzhen open field

Lightning test

Rocket-triggered lightening

5 kA Lightning

Strictest Testing — Higher Than Industry Standard

EfficientReliable Simple

14

Great Creative Topology, System Efficiency Is Up To 96%

90%

91%

92%

93%

94%

95%

96%

97%

10kVA UPS typical efficiency

Load rate

efficiency

•95%@25% load , high efficiency at low load rate•96%@50% load , energy saving

Typical load of 9kW , electric charge=0.16USD/kWh

Legacy UPS Present UPS in the industry

Huawei UPS

UPS Efficiency 85% 90% 95.8%UPS power dissipation per year(kWh) 13912 8760 3456

Total power cost per year(USD) 2226 1401 552

Power cost over HUAWEI UPS (USD) 1674 849 0

Patent topology , the No.1 system efficiency

0500

1000150020002500

Yearly Power Cost/USD

Cost reducing by 75%

EfficientReliable Simple

15

Built-in battery

• Super small volume, more suitable for

office,bank branches and so on

• Output interface is IEC socket , easy to

use

Flexible Backup Time Solutions

EfficientReliable Simple

External charger

0 1 2 3 4 5 6 7 8 936V charger 1A 3A 6A 9A 12A 15A

72V charger 1A 2A 4A 6A 8A 10A 12A

96V charger 1A 2A 4A 6A 8A 10A

The corresponding gear of the charging current

16

• Friendly Interactive Interface

• Parameters can be set through the panel, convenient and easy

LCD display, Easy Configuration And Management

Working Mode

Battery Capacity

Load rate

Working status

Setting menuOutput voltage level , Output frequency system ,Number of batteries , Total battery capacity , Charge current limit, Discharge time protection setting etc.

Active alarm display menuActive alarm information, including the alarm No, alarm ID, and alarm cause ID

Control menu Starts or shuts down the inverter, clears ADMC alarms, replaces batteries, synchronizes parallel parameters, and restores default settings

Historical alarm display menuDisplaying the latest 10 alarms

EfficientReliable Simple

17

Built-in maintain bypass to improve the maintainability Professional Version: Up to four units, easy to expand

• Auto-sensing parallel, easy to form N + X configuration

• The ring parallel line eliminates the failure of a single parallel

cable

• Only professtional 6/10kVA can support parallel

Up to Four parallel

Ring parallel line

• Protection lock , avoid maintenance bypass switch

was wrong operation

• Maintenance is convenient, simple and easy

Maintain bypass break

Protective lock

EfficientReliable Simple

18

Flexible Configuration and Maintenance Senior Management

• 20 to 16 cells per string for 6K/10K; 32 to 40 cells per string for 15/20K. When removing damaged batteries, the remaining batteries will work normally.

Damaged battery due to thermal runaway

• Automatic identification of electrical environment, enabling intelligent hibernation mode in a healthy grid.

• Detects battery states in real time and supports battery pre-alarm.

Old batteries can be reused.

Intelligent Management to Extend Battery Life

Intelligent Charge and Discharge

• Automatic equalized and float-charging conversion and temperature compensation function prevent battery over- or under-charging to extend battery life.

• Automatically adjusts discharge termination voltage in accordance with load condition and the discharge time.

Battery discharging curve

Battery voltageConstant voltage

Temperature compensation

Battery hibernation

×

EfficientReliable Simple

19

•Monitoring unit supports remote online

upgrade.

•Supports RS485, SNMP, USB, and dry

contact.

•Displays real-time system running state.

•Power supply and battery testing systems can

be controlled.

Remote online upgrade

Easy to manage

Integrated Monitoring System, easy remote management

NetEco 1000U

interface

USB SNMPModbus Dry contact

• Compact and easy to use, can be plugged into the USB

port

• Supports UPS real-time status inquiry via SMS

• Can be set to send UPS status and alarm information

timely

GSM

Modem

EfficientReliable Simple

20

Huawei UPS2000-A introduction

21

UPS Ports Introduction—1kVA

Standard ( Oversea ) Long Run ( Oversea )

国内版的输出插座

1. AC input socket 2.Input Socket Breaker 3. USB 4. RS-232

5 .Monitor card slot(optional) 6.External battery access 7. AC output socket 8. LCD Display Panel

9. Control Button

22

国内版的输出插座

UPS Ports Introduction—2kVA

Standard ( Oversea ) Long Run ( Oversea )

1. AC input socket 2. Input Socket Breaker 3. USB 4. RS-232

5. Monitor card slot(optional) 6. External battery access 7. AC output socket 8. LCD Display Panel

9. Control Button

23

国内版的输出插座

1. AC input socket 2. Input Socket Breaker 3. USB 4. RS-232

5. Monitor card slot(optional) 6. External battery access 7. AC output socket 8. C19 output socket

9. LCD Display Panel 10. Control Button

UPS Ports Introduction—3kVA

Standard ( Oversea ) Long Run ( Oversea )

24

(1) AC input circuit breaker (2) Optional card slot (3) USB port (4) MBS port

(5) EPO port (6) AC input terminal block (7) AC output terminal block (8) Battery wiring terminal block

UPS Ports Introduction—6/10kVA Standard Version

Standard Long-run

25

(1) AC input circuit breaker (2) Optional card slot (3) EPO port (4) USB port

(5) MBS port (6) Parallel port(7) Maintenance bypass circuit breaker

(8) AC output circuit breaker

(9) AC input terminal block(10) Jumper terminal block for a single UPS or a parallel system

(11) AC output terminal block

(12) Battery wiring terminal block

UPS Ports Introduction—6/10kVA

professional versionStandard Long-run

26

Huawei UPS2000-A competitiveness

27

No. Parameter Huawei UPS2000-A-6/10kVA Emerson GXE-6/10kVA Influence

1 Input voltage range 80-280Vac 120-288Vac Narrow input range increases battery use, shortening battery lifespan.

2 Output power factor 0.9 0.8 can't match the new IT load, increase the investment by the user

3Output Voltage accuracy 1% 3% Low output precision, can not better

protect user load

4 Efficiency 96% 91% More energy consumption, increased operating expenses

5Charging current(Long run )

8A4A

Charging current is small, cannot satisfy the bad power grid or longtime backup

6 Battery Voltage192-240V(can be set )

192V If one battery is damaged, the entire group of battery scrap

7 Reliability5 kA lightning protection, veneer coating, special protection for key device pin, pre-alarm for key component

2 kA lightning protectionLack of reliability may cause huge losses to the user

Emerson GXE

28

No. Parameter Huawei UPS2000-A-6/10kVA EATON CASTLE-6/10KVA Influence

1 Panel LCD LED light Unfriendly interface

2 Input voltage range 80-280V 120-275VNarrow input range increases battery use, shortening battery lifespan.

3 Charging current(Long run )

8A 4ACharging current is small, cannot satisfy the bad power grid or longtime backup

4Output Voltage accuracy 1% 2% Low output precision, can not

better protect user load

5 Efficiency 96% 94% More energy consumption, increased operating expenses

6 Over load 105%-125% 5min 105%-125% 1min

7 Reliability5 kA lightning protection, veneer coating, special protection for key device pin, pre-alarm for key component

2 kA lightning protectionLack of reliability may cause huge losses to the user

EATON CASTLE

29

Contents

11

44

33

22

HighlightsHighlights

Product introductionProduct introduction

Competitive strengths

Competitive strengths

Optional accessories Optional accessories

30

Huawei UPS2000-A Product options

31

UPS2000-A Optional Accessories

Battery switch box

Dry Contact Card

SNMP card

Modbus card

Dry contact card

Temperature and humidity sensor

Transformer

Battery pack

UPS2000-A

GSM Modem

Battery box

Battery Rack

External Charger

1/2/3kVA 6/10kVAUPS fixing stand

32

Optional Accessories-Battery Pack for 1/2/3kVA

Backup

timeSpecifications Number

17min ESS-72V12-9AHBPVBB 1PCS

39min ESS-72V12-9AHBPVBB 2PCS

Backup

timeSpecifications Number

17min ESS-96V12-9AHBPVBB 1PCS

39min ESS-96V12-9AHBPVBB 2PCS

Backup

timeSpecifications Number

15min ESS-36V12-9AHBPVBB 1PCS

36min ESS-36V12-9AHBPVBB 2PCSUPS2000-A Battery Pack

1K: Backup time of battery pack(100%load)

2K: Backup time of battery pack(100%load) 3K: Backup time of battery pack(100%load)

33

ESS-240V12-2*9AhBPVBA01*2

load (% ) load (W )1battery box backup time

2battery box backup time

100% 9000 12 28

80% 7200 15 40

60% 5400 23 52

40% 3600 40 79

ESS-240V12-2*7AhBPVBA01

load (% ) load (W )1battery box backup time

2battery box backup time

100% 5400 17 41

80% 4320 23 50

60% 3240 32 70

40% 2160 50 106

Optional Accessories-Battery box for 6/10kVA

10K: Backup time schedule of battery box

6K: Backup time schedule of battery box

UPS2000-A 6/10kVA battery box

34

MODBUS Card Dry Contact Card

UPS2000-A Card slot can hold three types of monitoring cards: Modbus card and Dry contact card

•Support the MODBUS RTU

communication protocol

•Provide the RS - 485 interface

•Support hot plug, convenient installation

•Provide contact signal, can remotely

monitor the UPS

Optional Accessories –Monitoring Card for 1/2/3kVA

Monitoring card slot

35

Optional Accessories –Monitoring Card for 6/10kVA

SNMP card

•Monitors, via NMS, NetEco, and the Web, the UPS.

operating status based on the computer network type.

• Environment temperature and humidity sensor can be

inserted in

SNMP to monitor surrounding information.Modbus card

• RS485 networking.

• Monitoring via the NetEco 1000U.

• Only one card required in parallel system.

Dry contact card

• 6 alarm outputs :( Normal mode , battery mode ,

bypass mode , Low battery voltage, Bypass

backfeed ,

UPS faults )

• 2 control inputs : Shutdown , reserved.

Card slot can hold three types

of monitoring cards.

Monitoring card slot

36

Optional Accessories –Battery Rack and Switch Box

Battery rack

Battery switch box

More connection type of battery racks

•Type of battery rack depends on

battery number and capacity.

Model Specifications UPS

PDC-63DC-440V 440VDC 63A 3/6/10kVA

+

-+

-

+ - + - + -

UPS

Rack 1 Rack 2 Rack 3 Rack 4

more battery racks connections

37

Optional Accessories –External charger

External charger side and LED indicator

1 DC connector 2 Status indicators3 Current selection switch 4 Power switch5 Mains input

Match with UPS

Status Indicator

In boost state

In float state

The On and Boost indicators are on.The On and Float indicators are on.

Full level50%Low level

The Full indicator is on.The MID indicator is on.The LOW indicator is on.

Independent use

Current selection switch36V charger 15A(max)72V charger 12A(max)96V charger 10A(max)

38

Optional Accessories - Transformer

Functions • Realize electric isolation

• Transformer ratio 2:1:1

• Output dual 110V or another 220V

Types• 6kVA transformers for 6K UPS

•10kVA transformers for 10K UPS

39

Optional Accessories -NetEco 1000U

• Real-time monitoring. NetEco 1000U monitors UPSs in real

time and allows users to configure and control UPSs

• Delay shutdown, shut down the computer application system

and operating system

• USB, SNMP, Modbus networking communication

• Historical data query. Query historical data and UPS alarm logs

through the NetEco 1000U.

• Remote alarm notification. NetEco 1000U notifies users via by

emails or SMS short messages immediately after a UPS

reports an alarm

The free NetEco 1000U can only support monitoring within ten UPSs.

An installation CD of NetEco 1000U is delivered with the UPS.

40

SpecificationCapacity ( kVA/kW ) 1/0.8 2/1.6 3/2.4 6/5.4 10/9

Input : Output 1-in : 1-out 1-in : 1-outInput

Mains

Rated Voltage 200/208/220/230/240 VAC 220/230/240 VACInput Voltage Range 110-300 VAC 80-280VACInput Frequency Range 40-70 Hz 50/60±5HzInput Power Factor > 0.99 >0.99

BatteryBattery voltage

Standard 24 V 48V 72 V 192 VLong run 36 V 72 V 96V 192-240V

OutputOutput Wiring Ph+N+PE Ph+N+PE

Output Sockets4 *IEC

C13(10A) 6*IEC C13(10A)6*IEC

C13(10A)— —

Rated Voltage 200/208/220/230/240 VAC ±1%220/230/240 VAC ±1% ( Standard version )208/220/230/240 VAC ±1% ( Professional version )

Rated Frequency 50/60±3Hz 50/60±5HzOutput Power Factor 0.8 0.9

Waveform < 3% ≤2%Efficiency 88% 89% 90% 96% 96%

EnvironmentalOperating temperature 0°C–40°C

Audible noise <50dB @ 1 Meter <50dB @ 1 MeterOthers

CertificationsYD/1095-2008 , EN/IEC 62040-1 , EN/IEC 62040-2 ,

EN/IEC 61000,CE, CB ,TLC

YD/1095-2008 , EN/IEC 62040-1 , EN/IEC 62040-2 ,EN/IEC 61000 , CE , CB , Rohs , TLC

Reach ,WEEECommunications RS485/Dry contact RS485/USB/Dry Contact/SNMP

41

Optional accessoriesMode

List UPS2000-A-1kTTSUPS2000-A-2kTTSUPS2000-A-1kTTS

UPS2000-A-1kTTLUPS2000-A-2kTTLUPS2000-A-1kTTL

UPS2000-A-6kTTS-SUPS2000-A-10kTTS-S

UPS2000-A-6kTTL-SUPS2000-A-10kTTL-S

UPS2000-A-6kTTS-PUPS2000-A-10kTTS-P

UPS2000-A-6kTTL-PUPS2000-A-10kTTL-P

Battery pack √

Battery box √ √ √

Battery Rack √ √ √

BCB box √ √ √

External charger √ √

SNMP/Mobus/dry contact

√ √ √ √ √ √

High voltage protection √ √

Anti-tilt mechanical part √ √ √ √

Outputtransformer

√ √

GSM modem √ √ √ √

Environment temperature and humidity sensor

√ √ √ √ √ √

Parallel cable √ √

THANK YOU

Copyright©2016 Huawei Technologies Co., Ltd. All Rights Reserved.The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.