HRW2112 WINDOW WATER CHAMBER

Embed Size (px)

Citation preview

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    1/30

    UNITWindow Water Chamber

    CO-OP

    Water Harvesting Streetwall

    NEIGHBORHOODUrban Well / Re uge / Watershed

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    2/30

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    3/30

    change your fixtures.

    [ other ][ baths ][ dishwasher ]

    [ faucets ] [ leaks ] [ toilets ] [ clothes washer ] [ showers ] 69.3 gallonsaverage household.

    e ciency xtures installed.

    45.2 gallonsdaily indoor water use per capita

    [ other ][ baths ][ dishwasher ]

    [ faucets ] [ leaks ]

    [ toilets ] [ clothes washer ] [ showers ]

    35% household reduction

    18.5 gal

    8.2 gal

    Water Closet Volume History pre-1978 ::6+ GPF

    1978 ::3.4 GPF

    1994 ::1.6-1.3 GPF Energy Policy Act of 1992 EPAct (low- ow toilets)

    (high e ciency toilets; pressure assisted)

    July 2012 ::1.28 GPF NYC Plumbing Code

    (super e ciency toilets)

    gallons per ush

    +1gal

    Plumbing Fixtures PF

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    4/30

    Figure 8: Croton Subsystem

    Overview of NYC Water Use System

    NY Watersheds

    River

    Disinfection +Conditioning

    Water Distribution Main

    Water Tunnel

    Aqueduct

    Storm Drain

    Roof Drain

    Sewage Treatment Plant

    Reservoirs

    Combined Sanitary + Storm Sewer

    During wet weather, increasedstormwater runoff exceedstreatment plant capacity causingthe combined sewer to flowdirectly to CSO outfall insteadof to waste treatment plants

    In some limited areas, primarilyin the outer boroughs, separatesanitary and storm sewers areavailable, which handle approxi-mately 20% of total volume.

    Regulator

    1

    2

    2

    1

    Combined Sewer Overflow (CSO) Outfall

    centralized municipal Water Supply

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    5/30

    decentralized WATER SUPPLEMENT [ rainwater + humidity harvesting ]

    Scales of OperationUNIT

    Window Water Chamber

    CO-OPWater Harvesting Streetwall

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    6/30

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    7/30

    BUILDING RESILIENCE

    ,

    . ,.

    , , ,

    ; , .,

    .

    ,, ,

    ,.

    ;

    .,

    , , , ,

    PERMITTED OBSTRUCTION

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    8/30

    Month_of_Year

    Toilet_Type

    Exterior_Obstruction

    Interior_Obstruction

    User_Demand Estimated_Use

    Water_Supplement_Zone

    Window_Water_Chamber water supplement

    [ reduction ] municipal water supply

    Pooky_Chute

    Header_Reservoir

    Header_to_Sill_Framing

    Collector_Shade

    Supply_Shade

    tenant allowance

    zoning permitted obstruction depth building oor

    Avg._Rainfall

    Humidity

    [ collector shade cavity area ]

    [ collector shade surface area ]

    [ o p t i m i z e i n s p r e a d s h e e t ]

    Speculated_Yield [ water collection ]

    Tenant_Count

    [ toilets ]

    UNIT Window Water Chamber

    CO-OP Water Harvesting Streetwall

    inter ace diagram ::

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    9/30

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    Collector_Basin

    sill

    header

    windo wo pening

    Header_to_Sill_Framing

    [ 4.2][ 3.2 ] [ 4.3 ] [ 4.2 ][ 4.3 ]

    [ 3.8 ][ 3.9 ][ 4.1 ][ 4.0 ][ 3.7 ][ 4.1 ][ 3.9 ][ 3.98 ]

    * and sun anglescoming soon...

    NYC rain all per month (in)

    UNIT Window Water Chamber select a month ::

    Month_of_Year Avg._Rainfall

    Humidity

    [ collector shade cavity area ]

    [ collector shade surface area ]

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    10/30

    Pooky_Chute

    Collector_Framing

    Collector_Shade

    Supply_Shade

    Header_to_Sill_Framing

    windo wo pening

    Collector_Basin

    UNIT Window Water Chamber add raming ::

    Month_of_Year Avg._Rainfall

    Humidity

    [ collector shade cavity area ]

    [ collector shade surface area ]

    Speculated_Yield [ water collection ]

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    11/30

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    Collector_Shade

    Collector_Basin

    windo wo pening

    Collector_Basin

    E xte rio r _Ob stru ct io n

    In terior _O

    b s truc tion

    UNIT Window Water Chamber declare permitted obstructions ::

    tenant allowance

    permitted obstructions

    Exterior_Obstruction

    Interior_Obstruction

    zoning permitted obstruction depth building oor

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    12/30

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    windo wo pening

    Collector_Basin

    E xte rio r _Ob stru ct io n

    In terior _O

    b s truc tion

    Collector_Shade

    Collector_Basin

    UNIT Window Water Chamber declare permitted obstructions ::

    Exterior_Obstruction

    Interior_ObstructionWater_Supplement_Zone

    zoning permitted obstruction depth building oor

    tenant allowance

    permitted obstructions

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    13/30

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    windo wo pening

    Collector_Basin

    Reservoir_Header

    In terior _O

    b s truc tion

    E xte rio r _Ob st ru ct io n

    [ 18.5 ]* [ 8.2 ]* fushing gallons[ 7.68 ]* (per person / day) * assuming 6 toilet fushes per day

    UNIT Window Water Chamber select toilet type ::

    Toilet_Type User_Demand Estimated_Use

    Tenant_Count

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    14/30

    [ predicted collection yield or March ]

    UNIT Window Water Chamber

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    15/30

    UNIT Window Water Chamber select supply shade type ::

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    [ faceted ]

    Collector_Basin

    Supply_Shade[ soft ] In ter

    ior _Ob s tru

    c tion

    E xte rio r _Ob stru ct io n

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    16/30

    UNIT Window Water Chamber

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    Collector_Basin

    Reservoir_Header

    Supply_Shade[ faceted ] I

    n terior _O

    b s truc tion

    E xte rio r _Ob st ru ct io n

    adjust shade length ::

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    17/30

    UNIT Window Water Chamber

    Pooky_Chute

    Collector_Shade

    Supply_Shade

    Collector_Basin

    Supply_Shade[ faceted ]

    In terior _O

    b s truc tion

    windo wo pening

    E xte rio r _Ob st ru ct io n

    adjust shade length ::

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    18/30

    CO-OP Water Harvesting Streetwall connect elements ::

    Pooky_Chute

    Pooky_Chute

    Pooky_Chute

    Supply_Shade

    Supply_Shade

    Supply_Shade

    In terior _O

    b s truc tion

    In terior

    _Ob s truc t

    ionIn terior _O

    b s truc tion

    E xte rio r _Ob stru ct io n

    E xte rio r _Ob stru ct io n

    E xt e rio r _Ob st ru ct io n

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    19/30

    Water Chamber Basin Water Chamber Basin[ impermeable surface ][width and depth parameters]

    Moisture Harvesting Sails[orientation and projection parameters]

    Tubular metal framing[sail + basin coordination]

    Bi-layer fabric[ OUTER hydrophilic dewetting membrane ][ INNER hydrophobic runoff mebrane ]

    Facade and Window Framing[sail + basin coordination]

    OBLIQUE VIEW OBLIQUE VIEW

    UNIT Window Water Chamber

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    20/30

    18%[ blockage ]

    35%

    50%FIGS. 3a to 3d show a textured surfaceinclined to the horizontal plane havinghydrophobic and hydrophilic regions.

    UNIT Window Water Chamber

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    21/30

    Water Chamber Basin[ impermeable surface ]

    Water Chamber Basin[ impermeable surface ]

    [Exterior Building Face]

    Moisture Harvesting Sails[orientation and projection parameters]

    Bi-layer fabric[ OUTER hydrophilic dewetting membrane ][ INNER hydrophobic runoff mebrane ]

    Facade Framing[sail + basin coordination]

    [Window Header]

    Window Framing

    Window Framing

    [sail + basin coordination]

    TOP VIEW BOTTOM VIEW

    M A X . P R O J E C T I O N

    ( 5 - 0 )

    M A X . P R O J E C T I O N

    5 -

    Tubular metal framing[sail + basin coordination]

    UNIT Window Water Chamber

    i d Ch b

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    22/30

    Water Chamber Basin

    Water Chamber Basin[ impermeable surface ]

    [width and depth parameters]

    [Window Header]

    [ E x t e r i o r

    B u

    i l d i n g

    F a

    c e

    ]

    [ E x t e r i o r

    B u

    i l d i n g

    F a

    c e

    ]

    Moisture Harvesting Sails[orientation and projection parameters]Bi-layer fabric

    [ OUTER hydrophilic dewetting membrane ][ INNER hydrophobic runoff mebrane ]

    Facade and Window Framing[sail + basin coordination]

    SIDE VIEW SIDE VIEW

    MA X.PROJECTION(5-0) MA X.PROJECTION(5-0)

    Tubular metal framing[sail + basin coordination]

    UNIT Window Water Chamber

    UNIT Wi d W Ch b

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    23/30

    Water Chamber Basin

    Water Chamber Basin[ impermeable surface ]

    [width and depth parameters]

    Moisture Harvesting Sails[orientation and projection parameters]

    Bi-layer fabric[ OUTER hydrophilic dewetting membrane ][ INNER hydrophobic runoff mebrane ]

    Facade and Window Framing

    EQ.

    [sail + basin coordination]

    FRONT VIEW REAR VIEW

    E Q .E Q .

    E Q .

    EQ. EQ.

    Tubular metal framing[sail + basin coordination]

    UNIT Window Water Chamber

    CO OP W H i S lli di id l i d i t ll ti

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    24/30

    street-side elevation section

    CO-OP Water Harvesting Streetwall individual window installation ::

    CO OP W t H ti St t llli k d i d i t ll ti

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    25/30

    CO-OP Water Harvesting Streetwall

    street-side elevation section

    linked window installation ::

    CO OP W t H ti g St t ll

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    26/30

    building-side elevation section

    CO-OP Water Harvesting Streetwall

    CO OP Water Harvesting Streetwall

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    27/30

    CO-OP Water Harvesting Streetwall

    CO OP Water Harvesting Streetwall

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    28/30

    CO-OP Water Harvesting Streetwall

    CO OP Water Harvesting Streetwall

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    29/30

    CO-OP Water Harvesting Streetwall

  • 8/2/2019 HRW2112 WINDOW WATER CHAMBER

    30/30

    UNITWindow Water Chamber

    CO-OPWater Harvesting Streetwall

    NEIGHBORHOODUrban Well / Re uge / Watershed