Key features
•Optimizedfordatacenterswithextensivevirtualizationandconvergencefeatures
•Broadinterfaceoptionsfrom1Gto100Gscalingupto24.3Tb/sswitchingcapacity
•SDNreadywithOpenFlow1.3support
•LargeLayer2andLayer3tablestosupportlargescaledeployments
•Fullyredundantarchitecturewithhotswappablecomponents
Product overview
TheHP12500SwitchSeriesisafamilyofpowerful,next-generationroutingswitcheswithoutstandingcapacityandscaleforthenetworkcoreordatacenter.
DesignedforhighperformancewithnonblockinganddistributedClosarchitecture,theseswitchesdeliverupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot.
The12500switchesalsohaveenergy-efficiencyfeaturesthatdrivedownoperationalexpensesandareidealfororganizationscontemplatinglarge-scaledatacenterconsolidations,businesscontinuityanddisasterrecoverysites,metropolitanareanetworkdeployments,andotherapplicationsrequiringarobust,reliable,andhighlyavailableswitchingplatform.
Data sheet
HP 12500 Switch Series
2
Data sheet | HP 12500 Switch Series
Features and benefits
Data center optimized•NEWScalableLayer2fabrics
Buildflexible,resilient,andscalableLayer2fabricswithSPBandHPIRF
•MultitenantDeviceContext(MDC)
Isaninnovativedatacentervirtualizationsolutionthatenablesmulti-tenancy,givingcustomerstheabilitytovirtualizeaphysicalswitchintomultiplelogicaldevices,witheachlogicalswitchhavingitsowntenants
•HPEthernetVirtualInterconnect(EVI)
IsanHPVirtualApplicationNetworkinnovationthatprovidesaLayer2extensionacrossthedatacentertosimplifytheinterconnectivityofgeographicallydispersedatacenters
•NEWDataCenterBridging(DCB)protocols
ProvidesupportforIEEE802.1QazDataCenterBridgingExchange(DCBX),EnhancedTransmissionSelection(ETS),andIEEE802.1QbbPriorityFlowControl(PFC)forconvergedfabrics
•NEWFibreChanneloverEthernet(FCoE)features
DeliversupportforFCoE,includingexpansion,fabric,trunkVFandNports,andaggregationofE-portandN-portvirtualization
•Acceleratedperformancewithjumboframes
Forintra-data-centercommunication,orfordatacentertodatacentertraffic(disasterrecovery),reducingtheamountoftimerequiredfordatabackupandrecovery
•Networkloadbalancing(NLB)multicastARP
Microsoft®NLBco-workswithmulticastARPtoprovideserverswithloadbalancingandfaultswitchover,whichlowerscostsandinvestment
3
Data sheet | HP 12500 Switch Series
Software-defined networking•NEWSupportsOpenFlow1.3specifications
ToenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths
Performance•NEWHighperformancedesignwithnonblockinganddistributedClosarchitecture
Deliversupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot
•NEWHigh-density1/10/40/100GbEinterfaceconnectivity
Offersupto18interfacemoduleslotstoscaleupto8641GbEor1/10GbEor28840GbEor72100GbEports
•Hardware-basedwirespeedaccesscontrollists(ACLs)
Helpprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation
•High-performanceprocessorsystem
Thesupervisormoduleusesthreedifferentprocessorstoisolatekeytasks:controlplane(STP,OSPF,BGP,MPLS,etc.),fastrecoveryprotocols(RRPP,BFD,etc.),andchassismanagement(temperature,power,etc.)
Product architecture•Distributedarchitecturewithseparationofdataandcontrolplanes
Deliversenhancedfaulttoleranceandfacilitatescontinuousoperationandzeroservicedisruptionduringplannedorunplannedcontrol-planeevents
•AdvancedComwaremodularOS
Bringsmodularity,enhancedserviceability,stabilityandindependentprocessmonitoringthroughmodernComwarev7OperatingSystem
•In-ServiceSoftwareUpgrade(ISSU)
Providesanupgradeoftheentirechassis,oranindividualtaskorprocess,withzeropacketloss
4
Data sheet | HP 12500 Switch Series
Resiliency and high availability•IntelligentResilientFramework(IRF)
Createsvirtualresilientswitchingfabrics,wheretwoormoreswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;caneliminatetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation
•Ultrafastprotocolconvergence
EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRP,MPLS,andIRF
•DeviceLinkDetectionProtocol(DLDP)
Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks
•Completesetofroutingprotocols(Layer3IPv4andIPv6)
SupportingwiderangeofroutingprotocolsincludingRIP,OSPF,IS-IS,andBGPforbothIPv4andIPv6alongwithcompletesupportofPIM-DM,PIM-SM,PIM-SSM,andMSDP
•Hotpatching
The12500SwitchSeriessupportshotpatching,allowingin-servicepatchingforsomeisolatedsoftwareproblems
•NonStopForwarding/GracefulRestart(NSF/GR)
Usingstandardized-basedIETFprotocols,the12500SwitchSeriesprovidesnonstopforwarding(switching/routing)forLayer3routingprotocols(controlplane–OSPF,BGP,andMPLS),providinghitlessfailover
•Fullyredundantandhotswappablecomponents
Providingfullhardwareredundancyforeachcomponentincludingpowersupplies,fantrays,supervisormodules,andfabricmodulestoenablethehighestlevelofavailability
•RapidRingProtectionProtocol(RRPP)
ProvidesfastrecoveryforringEthernet-basedtopology
5
Data sheet | HP 12500 Switch Series
Quality of Service (QoS)•VirtualOutputQueue(VOQ)
Preventshead-of-line(HOL)blockingandgracefullyhandlesburstydatacentertrafficincreasingswitchperformance
•IEEE802.1pprioritization
Deliversdatatodevicesbasedonthepriorityandtypeoftraffic
•Layer4prioritization
EnablesprioritizationbasedonTCP/UDPportnumbers
•Broadcastcontrol
Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic
•Advancedclassifier-basedQoS
ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorper-VLANbasis
•Bandwidthshaping
– Port-basedratelimiting
Providesper-portingress-/egress-enforcedmaximumbandwidth
– Classifier-basedratelimiting
UsesACLstoenforcemaximumbandwidthforingress/egresstrafficoneachport
Compartmentalization•Departmentprotection
Usingnetworkvirtualizationstandards(QinQ,VRF,andMPLS),the12500SwitchSeriesallowsorganizationstoisolatedifferentbusinessunitswithdifferentresources(VRFs);usingstandard-basedmechanisms,thenetworkiscompletelyvirtualized,reducingcostandoperations
•IEEE802.1ahProviderBackboneBridge(MACinMAC)
ProviderBackboneBridge(PBB)isaLayer2VPNtechnologythatallowsacompleteseparationofcustomerandproviderdomainsbysealingtheuserMACintheserviceproviderMAC,whichenhancesthescalabilityofanEthernetnetwork
6
Data sheet | HP 12500 Switch Series
Layer 2 switching•MultipleVLANRegistrationProtocol(MVRP)
HelpstomaintainVLANconfigurationdynamicallybasedoncurrentnetworkconfigurations
•GARPVLANRegistrationProtocol
AllowsautomaticlearninganddynamicassignmentofVLANs
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventsfloodingofIPmulticasttraffic
•IEEE802.1adQinQ
IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork
•BridgeProtocolDataUnit(BPDU)tunneling
TransmitsSTPBPDUstransparently,allowingcorrecttreecalculationsacrossserviceproviders,WANs,orMANs
•VLANsupportandtagging
SupportsIEEE802.1Q(4KVLANIDs)
•SpanningTree
The12500SwitchSeriessupportstheentiresetofSTPprotocols(STP,RSTP,andMSTP),facilitatingacompleteintegrationwithstandardnetworks
Layer 3 routing•Layer3IPv4routing
ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,IS-IS,andBGP
•RIPandRIPngsupport
ProvidescompletesupportofRIPforbothIPv4andIPv6
•OSPFandOSPFv3support
ProvidescompletesupportofOSPFforbothIPv4andIPv6
•IS-ISandIS-ISv6support
ProvidescompletesupportofIS-ISforbothIPv4andIPv6
•Equal-CostMultipath(ECMP)
Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth
•Layer3IPv6routing
ProvidesroutingofIPv6atmediaspeed;supportsstaticroutes,RIPng,OSPFv3,IS-ISv6,andBGP4+
•IPv6tunneling
AllowsasmoothtransitionfromIPv4toIPv6byencapsulatingIPv6trafficoveranexistingIPv4infrastructure
7
Data sheet | HP 12500 Switch Series
•Completemulticastprotocolstack
PIM-DM,PIM-SM,PIM-SSM,MSDP,andextensionstoBGPprovideoneofthemostcompletemulticastprotocolstacks
•Policyrouting
Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies
•MPLSsupport
ProvidesextendedsupportofMPLS,includingMPLSVPNsandMPLSTrafficEngineering(MPLSTE)
•VPLSsupport
ProvidesextendedsupportofVPLSfordatacentertodatacentercommunicationatLayer2;providessupportofhierarchicalVPLSforscalability
Management•sFlow
Providesscalable,ASIC-basednetworkmonitoringandaccounting;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes
•IEEE802.1abLLDPdiscovery
Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications
•USBsupport
– Filecopy
AllowsuserstocopyswitchfilestoandfromaUSBflashdrive
•Multipleconfigurationfiles
Storeseasilytotheflashimage
•Command-lineinterface(CLI)
Providesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated
•Managementinterfacecontrol
Enablesordisableseachofthefollowinginterfacesdependingonsecuritypreferences:consoleport,telnetport,andSSHport
•Out-of-bandinterface
Isolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane
8
Data sheet | HP 12500 Switch Series
•Networkmanagement
HPIntelligentManagementCenter(IMC)centrallyconfigures,updates,monitors,andtroubleshoots
•Networkmanagement
SNMPv2c/v3MIB-IIwithtraps
•RADIUSaccounting
Logsallsessiondetailsthatcanbeusedtogenerateusagereportsorinterfacetoabillingsystem
•RMON
Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents
•RemoteIntelligentMirroring
MirrorsingressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork
Connectivity•IPv6nativesupport
– IPv6host
EnablesswitchestobemanagedanddeployedattheIPv6network’sedge
– Dualstack(IPv4andIPv6)
TransitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols
– MulticastListenerDiscovery(MLD)snooping
ForwardsIPv6multicasttraffictotheappropriateinterface
– IPv6ACL/QoS
SupportsACLandQoSforIPv6networktraffic,preventingtrafficflooding
– IPv6routing
SupportsIPv6staticroutesandIPv6versionsofRIPandOSPFroutingprotocols
9
Data sheet | HP 12500 Switch Series
Security•ControlPlanePolicing(CoPP)
ProtectionagainstDoSattacksatinfrastructureroutersandswitches;easeofconfigurationforcontrolplanepolicies
•IEEE802.1XandRADIUSnetworklogins
Controlsport-basedaccessforauthenticationandaccountability
•SecureFTP
Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•DHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•DynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata
•SecureShell(SSHv2)
Encryptsalltransmitteddataforsecure,remoteCLIaccessoverIPnetworks
•Securemanagementaccess
Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2andSNMPv3
•ACLs
ProvideIPv4andIPv6filteringbasedonsource/destinationIPaddress/subnetandsource/destinationTCP/UDPportnumber
•Mediaaccesscontrol(MAC)authentication
Providessimpleauthenticationbasedonauser’sMACaddress;supportslocalorRADIUS-basedauthentication
Convergence•Layers2,3,and4QoSmechanisms
SupportDiffServprioritytaggingbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,andsourceport
•IPmulticastsnoopinganddata-drivenIGMP
AutomaticallypreventfloodingofIPmulticasttraffic
•LLDP-MED
Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones
•InternetGroupManagementProtocol(IGMP)
UtilizesAny-SourceMulticast(ASM)orSource-SpecificMulticast(SSM)tomanageIPv4multicastnetworks;supportsIGMPv1,v2,andv3
•ProtocolIndependentMulticast(PIM)
DefinesmodesofInternetIPv4andIPv6multicastingtoallowone-to-manyandmany-to-manytransmissionofinformation;supportsPIMDenseMode(DM),SparseMode(SM),andSource-SpecificMode(SSM)
10
Data sheet | HP 12500 Switch Series
•MulticastSourceDiscoveryProtocol(MSDP)
AllowsmultiplePIM-SMdomainstointeroperate;isusedforinter-domainmulticastapplications
•MulticastVLAN
AllowsmultipleVLANstoreceivethesameIPv4orIPv6multicasttraffic,lesseningnetworkbandwidthdemandbyreducingoreliminatingmultiplestreamstoeachVLAN
Monitor and diagnostics•Portmirroring
Enablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring
•Connectivityfaultdetection(IEEE802.1ag)
Connectivityfaultdetection(CFD)providesaLayer2linkOperations,Administration,andMaintenance(OAM)mechanismusedforlinkconnectivitydetectionandfaultlocating
Integration•12500VPN20Gb/sFirewallModule
Providesenhancedstatefulpacketinspectionandfiltering;supportsflexiblesecurityzonesandvirtualfirewallcontainment;deliversadvancedVPNserviceswith3DESandAESencryptionathighperformanceandlowlatency;offersWebcontentfilteringandapplicationprioritizationandoptimization
Investment protection•Modularswitchfabric
Providesinvestmentprotectionbyenablingfutureperformanceupgradesandincreasedportdensity
•Environmentallyfriendly
ROHSsupportandlowpowerconsumptionbasedonthelatesttechnologyprovideoutstandingpowerefficiency
Warranty and support•1-yearwarranty
Advancehardwarereplacementwith10-calendar-daydelivery(availableinmostcountries)
•Electronicandtelephonesupport
Limitedelectronicandbusiness-hourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/warrantysummary.
•Softwarereleases
Tofindsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/warrantysummary.
11
Data sheet | HP 12500 Switch Series
HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)
I/O ports and slots 4openmoduleslots
Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
4openmoduleslots
Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination
8openmoduleslots
Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots
4switchfabricslots
2MPU(formanagementmodules)slots
4switchfabricslots
2MPU(formanagementmodules)slots
9switchfabricslots
Physical characteristics
Dimensions
Weight
Fullconfigurationweight
17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)(10Uheight)
132.28lb(60kg)
220.46lb(100kg)
17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)
132.28lb(60kg)
220.46lb(100kg)
17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)
209.44lb(95kg)
374.78lb(170kg)
Memory and processor
Gigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet
MountsinanEIA-standard19in.telcorackorequipmentcabinet
MountsinanEIA-standard19in.telcorackorequipmentcabinet
Performance
Throughput
Routing/Switchingcapacity
1920Mpps
3240Gb/s
1920Mpps
3240Gb/s
3840Mpps
6120Gb/s
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
HP 12500 Switch Series
Specifications
12
Data sheet | HP 12500 Switch Series
HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)
Electrical characteristics
Frequency
Description
Maximumheatdissipation
ACvoltage
DCvoltage
Maximumpowerrating
50/60Hz
8123BTU/hr(8569.77kJ/hr)
100-120/200-240VAC
2380W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
8123BTU/hr(8569.77kJ/hr)
-48to-60VDC
2380W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
50/60HzAchievedMiercomCertifiedGreenAward
10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.
14587BTU/hr(15389.29kJ/hr)
100-120/200-240VAC
4750W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
13
Data sheet | HP 12500 Switch Series
HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticfield
Voltagedipsandinterruptions
Harmonics
Flicker
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
14
Data sheet | HP 12500 Switch Series
HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)
I/O ports and slots 8openmoduleslots
Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
18openmoduleslots
Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
18openmoduleslots
Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots
9switchfabricslots
2MPU(formanagementmodules)slots
9switchfabricslots
2MPU(formanagementmodules)slots
9switchfabricslots
Physical characteristics
Dimensions
Weight
Fullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)
209.44lb(95kg)
374.78lb(170kg)
17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)
352.74lb(160kg)
639.33lb(290kg)
17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)
352.74lb(160kg)
639.33lb(290kg)
Memory and processor
Gigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet
MountsinanEIA-standard19in.telcorackorequipmentcabinet
MountsinanEIA-standard19in.telcorackorequipmentcabinet
Performance
Throughput
Routing/Switchingcapacity
3840Mpps
6120Gb/s
8640Mpps
13.3Tb/s
8640Mpps
13.3Tb/s
HP 12500 Switch Series
Specifications (continued)
15
Data sheet | HP 12500 Switch Series
HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
DCvoltage
Maximumpowerrating
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC
4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
50/60Hz
32859BTU/hr(34666.24kJ/hr)
100-120/200-240VAC
10700W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC
10700W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
16
Data sheet | HP 12500 Switch Series
HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticfield
Voltagedipsandinterruptions
Harmonics
Flicker
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);
SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);
SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);
SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
17
Data sheet | HP 12500 Switch Series
HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)
I/O ports and slots 8openmoduleslots
Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
8openmoduleslots
Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots
9switchfabricslots
2MPU(formanagementmodules)slots
9switchfabricslots
Physical characteristics
Dimensions
Weight
Fullconfigurationweight
17.4(w)x29.13(d)x38.39(h)in(44.2x74.0x97.51cm)(22Uheight)
242.51lb(110kg)
374.78lb(170kg)
17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)
209.44lb(95kg)
374.78lb(170kg)
Memory and processor
Gigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet
Performance
Throughput
Routing/Switchingcapacity
4800Mpps
10.8Tb/s
4800Mpps
10.8Tb/s
HP 12500 Switch Series
Specifications (continued)
18
Data sheet | HP 12500 Switch Series
HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
Electrical characteristics
Frequency
Description
Maximumheatdissipation
ACvoltage
DCvoltage
Maximumpowerrating
50/60Hz
AchievedMiercomCertifiedGreenAward
10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.
14587BTU/hr(15389.29kJ/hr)
100-120/200-240VAC
4750W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
14587BTU/hr(15389.29kJ/hr)
-48to-60VDC
4750W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
19
Data sheet | HP 12500 Switch Series
HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticfield
Voltagedipsandinterruptions
Harmonics
Flicker
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
20
Data sheet | HP 12500 Switch Series
HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)
I/O ports and slots 18openmoduleslots
Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
18openmoduleslots
Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination
Additional ports and slots 2MPU(formanagementmodules)slots
9switchfabricslots
2MPU(formanagementmodules)slots
9switchfabricslots
Physical characteristics
Dimensions
Weight
Fullconfigurationweight
17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)
352.74lb(160kg)
639.33lb(290kg)
17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)
352.74lb(160kg)
639.33lb(290kg)
Memory and processor
Gigabitmodule
10Gmodule
Managementmodule
Fabric
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)
PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)
QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM
PowerPC@400MHz,128MBRAM
Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet
Performance
Throughput
Routing/Switchingcapacity
10.8Bpps
24.3Tb/s
10.8Bpps
24.3Tb/s
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
32°Fto104°F(0°Cto40°C)
5%to95%,noncondensing
-40°Fto158°F(-40°Cto70°C)
5%to95%,noncondensing
HP 12500 Switch Series
Specifications (continued)
21
Data sheet | HP 12500 Switch Series
HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
DCvoltage
Maximumpowerrating
50/60Hz
32859BTU/hr(34666.24kJ/hr)
100-120/200-240VAC
10700W
NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
32859BTU/hr(34666.24kJ/hr)
-48to-60VDC
10700W
Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.
Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance
Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticfield
Voltagedipsandinterruptions
Harmonics
Flicker
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
ETSIEN300386V1.3.3
EN55024:1998+A1:2001+A2:2003
EN61000-4-2;IEC61000-4-2
EN61000-4-3;IEC61000-4-3
EN61000-4-4;IEC61000-4-4
EN61000-4-5;IEC61000-4-5
EN61000-4-6;IEC61000-4-6
IEC61000-4-8;EN61000-4-8
EN61000-4-11;IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface
Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.
22
Data sheet | HP 12500 Switch Series
Standards and Protocols
(appliestoallproductsinseries)
BGP RFC1657DefinitionsofManagedObjectsforBGPv4
RFC1771BGPv4
RFC1772ApplicationoftheBGP
RFC1773ExperiencewiththeBGP-4Protocol
RFC1774BGP-4ProtocolAnalysis
RFC1997BGPCommunitiesAttribute
RFC1998PPPGandalfFZACompressionProtocol
RFC2385BGPSessionProtectionviaTCPMD5
RFC2439BGPRouteFlapDamping
RFC2796BGPRouteReflection
RFC2842CapabilityAdvertisementwithBGP-4
RFC2858BGP-4Multi-ProtocolExtensions
RFC2918RouteRefreshCapability
Denial of service protection RFC2267NetworkIngressFiltering AutomaticFilteringofwellknownDenialofServicePackets
CPUDoSProtection
RateLimitingbyACLs
Device management RFC1155StructureandMgmtInformation(SMIv1)
RFC1157SNMPv1/v2c
RFC1305NTPv3
RFC1945HypertextTransferProtocol—HTTP/1.0
RFC2452MIBforTCP6
RFC2454MIBforUDP6
RFC2573(SNMPv3Applications)
RFC2578-2580SMIv2
RFC2579(SMIv2TextConventions)
RFC2580(SMIv2Conformance)
RFC2819(RMONgroupsAlarm,Event,HistoryandStatisticsonly)
RFC2819RMON
RFC3417(SNMPTransportMappings)SNMPv3andRMON
RFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+
General protocols IEEE802.1adQ-in-Q
IEEE802.1agServiceLayerOAM
IEEE802.1ahProviderBackboneBridges
IEEE802.1DMACBridges
IEEE802.1pPriorityIEEE802.1QVLANs
IEEE802.1sMultipleSpanningTrees
IEEE802.1vVLANclassificationbyProtocolandPort
IEEE802.1wRapidReconfigurationofSpanningTree
IEEE802.1XPAE
IEEE802.3ab1000BASE-T
IEEE802.3adLinkAggregation(LAG)
IEEE802.3ae10-GigabitEthernet
IEEE802.3ahEthernetinFirstMileoverPointtoPointFiber-EFMF
IEEE802.3ba40and100GigabitEthernetArchitecture
IEEE802.3i10BASE-T
IEEE802.3u100BASE-X
IEEE802.3xFlowControl
IEEE802.3z1000BASE-X
RFC768UDP
RFC783TFTPProtocol(revision2)
RFC791IP
RFC792ICMP
RFC793TCP
RFC826ARP
RFC854TELNET
RFC868TimeProtocol
RFC903RARP
RFC951BOOTP
RFC959FileTransferProtocol(FTP)
RFC1027ProxyARP
RFC1042IPDatagrams
RFC1350TFTPProtocol(revision2)
RFC1519CIDR
RFC1542BOOTPExtensions
RFC1812IPv4Routing
RFC2131DHCP
RFC2338VRRP
RFC2784GenericRoutingEncapsulation(GRE)
RFC2865RemoteAuthenticationDialInUserService(RADIUS)
IP multicast RFC1112IGMP
RFC2236IGMPv2
RFC2283MultiprotocolExtensionsforBGP-4
RFC2362PIMSparseMode
RFC2934ProtocolIndependentMulticastMIBforIPv4
RFC3376IGMPv3
RFC3618MulticastSourceDiscoveryProtocol(MSDP)
RFC4601PIMSparseMode
23
Data sheet | HP 12500 Switch Series
Standards and Protocols
(appliestoallproductsinseries)
IPv6 RFC1350TFTP
RFC1981IPv6PathMTUDiscovery
RFC2080RIPngforIPv6
RFC2460IPv6Specification
RFC2461IPv6NeighborDiscovery
RFC2462IPv6StatelessAddressAuto-configuration
RFC2463ICMPv6
RFC2473GenericPacketTunnelinginIPv6
RFC2475IPv6DiffServArchitecture
RFC2529TransmissionofIPv6PacketsoverIPv4
RFC2710MulticastListenerDiscovery(MLD)forIPv6
RFC2740OSPFv3forIPv6
RFC2893TransitionMechanismsforIPv6HostsandRouters
RFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)
RFC3315DHCPv6(clientonly)
RFC3484DefaultAddressSelectionforIPv6RFC3513IPv6AddressingArchitecture
RFC3587IPv6GlobalUnicastAddressFormat
RFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6
RFC4251SSHv6Architecture
RFC4252SSHv6Authentication
RFC4253SSHv6TransportLayer
RFC4254SSHv6Connection
RFC4541IGMP&MLDSnoopingSwitch
RFC4862IPv6StatelessAddressAuto-configuration
MIBs IEEE8023-LAG-MIB
RFC1213MIBII
RFC1229InterfaceMIBExtensions
RFC1286BridgeMIB
RFC1493BridgeMIB
RFC1573SNMPMIBII
RFC1643EthernetMIB
RFC1657BGP-4MIB
RFC1724RIPv2MIB
RFC1757RemoteNetworkMonitoringMIB
RFC1850OSPFv2MIB
RFC2011SNMPv2MIBforIP
RFC2012SNMPv2MIBforTCP
RFC2013SNMPv2MIBforUDP
RFC2021RMONv2MIB
RFC2096IPForwardingTableMIB
RFC2233InterfacesMIB
RFC2273SNMP-NOTIFICATION-MIB
RFC2452IPV6-TCP-MIB
RFC2454IPV6-UDP-MIB
RFC2465IPv6MIB
RFC2466ICMPv6MIB
RFC2571SNMPFrameworkMIB
RFC2572SNMP-MPDMIB
RFC2573SNMP-TargetMIB
RFC2613SMONMIB
RFC2618RADIUSClientMIB
RFC2620RADIUSAccountingMIB
RFC2665Ethernet-Like-MIB
RFC2674802.1pandIEEE802.1QBridgeMIB
RFC2737EntityMIB(Version2)
RFC2787VRRPMIB
RFC2819RMONMIB
RFC2863TheInterfacesGroupMIB
RFC2925PingMIB
RFC2932IP(MulticastRoutingMIB)
RFC2933IGMPMIB
RFC3273HC-RMONMIB
RFC3414SNMP-Userbased-SMMIB
RFC3415SNMP-Viewbased-ACMMIB
RFC3418MIBforSNMPv3
RFC3621PowerEthernetMIB
RFC3813MPLSLSRMIB
RFC3814MPLSFTNMIB
RFC3815MPLSLDPMIB
RFC3826AESforSNMP’sUSMMIB
RFC4133EntityMIB(Version3)
LLDP-EXT-DOT1-MIB
LLDP-EXT-DOT3-MIB
LLDP-MIB
MPLS RFC2205ResourceReSerVationProtocol(RSVP)-Version1FunctionalSpecification
RFC2209ResourceReSerVationProtocol(RSVP)
RFC2702RequirementsforTrafficEngineeringOverMPLS
RFC2858MultiprotocolExtensionsforBGP-4
RFC3031MultiprotocolLabelSwitchingArchitecture
RFC3032MPLSLabelStackEncoding
RFC3036LDPSpecification
RFC3107CarryingLabelInformationinBGP-4
RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnels
RFC3479FaultTolerancefortheLabelDistributionProtocol(LDP)
RFC3487GracefulRestartMechanismforLDP
RFC4090FastRerouteExtensionstoRSVP-TEforLSPTunnels
RFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)
RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailures
RFC4447PseudowireSetupandMaintenanceUsingLDP
RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworks
RFC4664FrameworkforLayer2VirtualPrivateNetworks
RFC4665ServiceRequirementsforLayer2ProviderProvisionedVirtualPrivateNetworks
RFC4761VirtualPrivateLANService(VPLS)UsingBGPforAuto-DiscoveryandSignaling
RFC4762VirtualPrivateLANService(VPLS)UsingLabelDistributionProtocol(LDP)Signaling
24
Data sheet | HP 12500 Switch Series
Standards and Protocols
(appliestoallproductsinseries)
Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
IEEE802.1D(STP)
RFC1155StructureofManagementInformation
RFC1157SNMPv1
RFC1215SNMPGenerictraps
RFC1757RMON4groups:Stats,History,AlarmsandEvents
RFC1905SNMPv2ProtocolOperations
RFC2211Controlled-LoadNetwork
RFC2272SNMPv3ManagementProtocolRFC2273SNMPv3Applications
RFC2274USMforSNMPv3
RFC2571SNMPManagementFrameworksRFC2572SNMPv3MessageProcessing
RFC2573SNMPv3Applications
RFC2576CoexistencebetweenSNMPversions
RFC2578SMIv2
RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm)and9(events)
RFC3164BSDsyslogProtocol
RFC3415SNMPv3View-basedAccessControlModelVACM)
ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)
SNMPv1/v2c/v3
OSPF RFC1245OSPFprotocolanalysis
RFC1246ExperiencewithOSPF
RFC1587OSPFNSSA
RFC1765OSPFDatabaseOverflow
RFC1850OSPFv2ManagementInformationBase(MIB),traps
RFC2328OSPFv2
RFC2370OSPFOpaqueLSAOption
RFC3101OSPFNSSA
RFC3623GracefulOSPFRestart
QoS/CoS IEEE802.1P(CoS)
RFC2212GuaranteedQualityofService
RFC2474DSFieldintheIPv4andIPv6Headers
RFC2475DiffServArchitecture
RFC2597DiffServAssuredForwarding(AF)
RFC2598DiffServExpeditedForwarding(EF)
RFC2697ASingleRateThreeColorMarker
RFC2698ATwoRateThreeColorMarkerBi-directionalRateShaping
Security IEEE802.1AEMACSecurityStandard(MACSec)
IEEE802.1XPortBasedNetworkAccessControl
RFC1321TheMD5Message-DigestAlgorithmRFC2082RIP-2MD5Authentication
RFC2104Keyed-HashingforMessageAuthentication
RFC2716PPPEAPTLSAuthenticationProtocol
RFC2865RADIUSAuthentication
RFC2866RADIUSAccounting
RFC2867RADIUSAccountingModificationsforTunnelProtocolSupport
RFC2868RADIUSAttributesforTunnelProtocolSupport
RFC2869RADIUSExtensions
RFC3567IntermediateSystem(IS)toISCryptographicAuthentication
AccessControlLists(ACLs)
GuestVLANfor802.1x
MACAuthentication
SSHv2SecureShell
WebAuthentication
IKEv1 RFC2865—RemoteAuthenticationDialInUserService(RADIUS)
25
Data sheet | HP 12500 Switch Series
HP 12500 Switch Series accessories
Modules NEWHPFlexFabric12500EMainProcessingUnit(JG802A)
HP12500TypeAMainProcessingUnitwithComwarev7OperatingSystem(JG497A)
HP12500MainProcessingUnit(JC072B)
NEWHPFlexFabric125004-port100GbECFPFDModule(JG786A)
NEWHPFlexFabric125004-port100GbECFPFGModule(JG788A)
NEWHPFlexFabric1250016-port40GbEQSFP+FDModule(JG790A)
NEWHPFlexFabric1250048-port1/10GbESFP+FDModule(JG796A)
NEWHPFlexFabric1250040-port1/10GbESFP+FDModule(JG792A)
NEWHPFlexFabric1250040-port1/10GbESFP+FGModule(JG794A)
HP1250016-port10GbESFP+LEBModule(JC782A)
HP1250016-port10GbESFP+LECModule(JC783A)
HP1250032-port10GbESFP+REBModule(JC064B)
HP1250032-port10GbESFP+RECModule(JC476B)
HP125008-port10GbESFP+LEBModule(JC780A)
HP125008-port10GbESFP+LECModule(JC781A)
HP125008-port10GbESFP+LEFModule(JC659A)
HP125008-port10GbEXFPLEBModule(JC073B)
HP125008-port10GbEXFPLECModule(JC068B)
HP1250048-portGig-TLEBModule(JC074B)
HP1250048-portGig-TLECModule(JC065B)
HP1250048-portGbESFPLEBModule(JC075B)
HP1250048-portGbESFPLECModule(JC069B)
HP1250048-portGbESFPLEFModule(JC660A)
HP12500PowerMonitorModule(JC502A)
26
Data sheet | HP 12500 Switch Series
Transceivers HPX120100M/1GSFPLCLXTransceiver(JF832A)
HPX114100MSFPLCFXTransceiver(JF833A)
HPX1251GSFPLCLH401310nmTransceiver(JD061A)
HPX1201GSFPLCLH401550nmTransceiver(JD062A)
HPX1251GSFPLCLH70Transceiver(JD063B)
HPX1201GSFPRJ45TTransceiver(JD089B)
HPX1201GSFPLCBX10-UTransceiver(JD098B)
HPX1201GSFPLCBX10-DTransceiver(JD099B)
HPX1201GSFPLCLH100Transceiver(JD103A)
HPX1701GSFPLCLH701550Transceiver(JD109A)
HPX1701GSFPLCLH701570Transceiver(JD110A)
HPX1701GSFPLCLH701590Transceiver(JD111A)
HPX1701GSFPLCLH701610Transceiver(JD112A)
HPX1701GSFPLCLH701470Transceiver(JD113A)
HPX1701GSFPLCLH701490Transceiver(JD114A)
HPX1701GSFPLCLH701510Transceiver(JD115A)
HPX1701GSFPLCLH701530Transceiver(JD116A)
HPX1201GSFPLCSXTransceiver(JD118B)
HPX1201GSFPLCLXTransceiver(JD119B)
HPX13010GXFPLCZRTransceiver(JD107A)
HPX13010GXFPLCLRTransceiver(JD108B)
HPX13010GXFPLCSRTransceiver(JD117B)
HPX13510GXFPLCERTransceiver(JD121A)
HPX18010GXFPLCLH80km1538.98nmDWDMTransceiver(JG226A)
HPX18010GXFPLCLH80km1539.77nmDWDMTransceiver(JG227A)
HPX18010GXFPLCLH80km1540.56nmDWDMTransceiver(JG228A)
HPX18010GXFPLCLH80km1542.14nmDWDMTransceiver(JG229A)
HPX18010GXFPLCLH80km1542.94nmDWDMTransceiver(JG230A)
HPX18010GXFPLCLH80km1558.98nmDWDMTransceiver(JG231A)
HPX18010GXFPLCLH80km1559.79nmDWDMTransceiver(JG232A)
HPX18010GXFPLCLH80km1560.61nmDWDMTransceiver(JG233A)
HPX13010GSFP+LCSRTransceiver(JD092B)
HPX13010GSFP+LCLRMTransceiver(JD093B)
HPX13010GSFP+LCLRTransceiver(JD094B)
HPX13010GSFP+LCER40kmTransceiver(JG234A)
HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)
HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)
HPX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)
HPX14040GQSFP+MPOSR4Transceiver(JG325B)
HPX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)
HPX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)
NEWHPX150100GCFPLCLR410kmSMTransceiver(JG829A)
HPX13010GSFP+LCLH80kmTransceiver(JG915A)
Cables HPPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)
HPPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)
HPPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)
HPPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)
HPPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)
HPPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)
Mounting Kit HPX421ChassisUniversal4-postRackMountingKit(JC665A)
Appliance HP1250020GbpsVPNFirewallModule(JG371A)
HP 12500 Switch Series accessories (continued)
27
Data sheet | HP 12500 Switch Series
Memory NEWHPFlexFabric4GBCompactFlashCard(JG806A)
NEWHPFlexFabric4GBDDR3SDRAM(JG807A)
HPX6001GCompactFlashCard(JC684A)
HP2GBRegisteredDDR2SDRAMMemory(JC609A)
HPX6101GBDDR2SDRAMMemory(JC071A)
HP 12504 AC Switch Chassis (JC654A) HP1250xG2FabricModule(JC658A)
HP12500ACPowerEntryModule(JF426A)
HP125002000WACPowerSupply(JF429A)
HP12504FanAssembly(JC664A)
HP 12504 DC Switch Chassis (JC655A) HP1250xG2FabricModule(JC658A)
HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)
HP125001800WDCPowerSupply(JC651A)
HP12504FanAssembly(JC664A)
HP 12508 AC Switch Chassis (JF431C) HP12508FabricModule(JC067B)
HP1250xG2FabricModule(JC658A)
HP12508TopandBottomCableGuidesforACPoweredSwitch(JC785A)
HP12500SideCableManagementGuide(JC084A)
HP125002000WACPowerSupply(JF429A)
HP12500ACPowerEntryModule(JF426A)HP12508FanAssembly(JC081A)
HP12508OptionalAirFilter(JC082A)
HP 12508 DC Switch Chassis (JC652A) HP12508FabricModule(JC067B)
HP1250xG2FabricModule(JC658A)
HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)
HP12500SideCableManagementGuide(JC084A)
HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)
HP125001800WDCPowerSupply(JC651A)
HP12508FanAssembly(JC081A)
HP12508OptionalAirFilter(JC082A)
HP 12518 AC Switch Chassis (JF430C) HP12518G2FabricModule(JC657A)
HP12518FabricModule(JC066A)
HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)
HP12500SideCableManagementGuide(JC084A)
HP125002000WACPowerSupply(JF429A)
HP12500ACPowerEntryModule(JF426A)
HP12518FanAssembly(JC080A)
HP12518OptionalAirFilter(JC083A)
HP 12518 DC Switch Chassis (JC653A) HP12518G2FabricModule(JC657A)
HP12518FabricModule(JC066A)
HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)
HP12500SideCableManagementGuide(JC084A)
HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)
HP125001800WDCPowerSupply(JC651A)
HP12518FanAssembly(JC080A)
HP12518OptionalAirFilter(JC083A)
HP FlexFabric 12508E AC Switch Chassis (JG782A)
NEWHPFlexFabric12508EFabricModule(JG798A)
NEWHPFlexFabric12508EOptionalExtendedCableGuideforACPoweredSwitch(JG830A)
NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)
HP125002000WACPowerSupply(JF429A)
NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)
NEWHPFlexFabric12500EFanTrayAssembly(JG805A)
NEWHPFlexFabric12508EOptionalAirFilter(JG808A)
HP 12500 Switch Series accessories (continued)
RatethisdocumentSharewithcolleagues
Sign up for updates hp.com/go/getupdated
©Copyright2010-2014Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.
MicrosoftisaregisteredtrademarkoftheMicrosoftgroupofcompanies.
4AA3-0666ENW,August2014,Rev.13
Datasheet|HP12500SwitchSeries
ProductswithinthisserieshaveachievedsufficientscoresineachoftheratedcriteriatoachievetheMiercomCertifiedGreendistinctionAward.SeetheSpecificationssectionofthisseriesformoreinformation.
HP FlexFabric 12508E DC Switch Chassis (JG783A)
NEWHPFlexFabric12508EFabricModule(JG798A)
HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)
HP12500SideCableManagementGuide(JC084A)
HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)
NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)
HP125001800WDCPowerSupply(JC651A)
NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)
NEWHPFlexFabric12500EFanTrayAssembly(JG805A)
NEWHPFlexFabric12508EOptionalAirFilter(JG808A)
HP FlexFabric 12518E AC Switch Chassis (JG784A)
NEWHPFlexFabric12518EFabricModule(JG800A)
HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)
HP12500SideCableManagementGuide(JC084A)
NEWHPFlexFabric12518EOptionalExtendedCableGuideforACPoweredSwitch(JG831A)
HP125002000WACPowerSupply(JF429A)
HP12500ACPowerEntryModule(JF426A)
NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)
NEWHPFlexFabric12500EFanTrayAssembly(JG805A)
NEWHPFlexFabric12518EOptionalAirFilter(JG809A)
HP FlexFabric 12518E DC Switch Chassis (JG785A)
NEWHPFlexFabric12518EFabricModule(JG800A)
HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)
HP12500SideCableManagementGuide(JC084A)
HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)
NEWHPFlexFabric12518EOptionalExtendedCableGuideforDCPoweredSwitch(JG833A)
HP125001800WDCPowerSupply(JC651A)
NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)
NEWHPFlexFabric12500EFanTrayAssembly(JG805A)
NEWHPFlexFabric12518EOptionalAirFilter(JG809A)
Learn more at hp.com/networking
HP 12500 Switch Series accessories (continued)