28
Key features • Optimized for data centers with extensive virtualization and convergence features • Broad interface options from 1G to 100G scaling up to 24.3 Tb/s switching capacity • SDN ready with OpenFlow 1.3 support • Large Layer 2 and Layer 3 tables to support large scale deployments • Fully redundant architecture with hot swappable components Product overview The HP 12500 Switch Series is a family of powerful, next-generation routing switches with outstanding capacity and scale for the network core or data center. Designed for high performance with nonblocking and distributed Clos architecture, these switches deliver up to 24.3 Tb/s switching capacity and 10.8 Bpps throughput with up to 400 Gb/s per line card slot. The 12500 switches also have energy-efficiency features that drive down operational expenses and are ideal for organizations contemplating large-scale data center consolidations, business continuity and disaster recovery sites, metropolitan area network deployments, and other applications requiring a robust, reliable, and highly available switching platform. Data sheet HP 12500 Switch Series

HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

Key features

•Optimizedfordatacenterswithextensivevirtualizationandconvergencefeatures

•Broadinterfaceoptionsfrom1Gto100Gscalingupto24.3Tb/sswitchingcapacity

•SDNreadywithOpenFlow1.3support

•LargeLayer2andLayer3tablestosupportlargescaledeployments

•Fullyredundantarchitecturewithhotswappablecomponents

Product overview

TheHP12500SwitchSeriesisafamilyofpowerful,next-generationroutingswitcheswithoutstandingcapacityandscaleforthenetworkcoreordatacenter.

DesignedforhighperformancewithnonblockinganddistributedClosarchitecture,theseswitchesdeliverupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot.

The12500switchesalsohaveenergy-efficiencyfeaturesthatdrivedownoperationalexpensesandareidealfororganizationscontemplatinglarge-scaledatacenterconsolidations,businesscontinuityanddisasterrecoverysites,metropolitanareanetworkdeployments,andotherapplicationsrequiringarobust,reliable,andhighlyavailableswitchingplatform.

Data sheet

HP 12500 Switch Series

Page 2: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

2

Data sheet | HP 12500 Switch Series

Features and benefits

Data center optimized•NEWScalableLayer2fabrics

Buildflexible,resilient,andscalableLayer2fabricswithSPBandHPIRF

•MultitenantDeviceContext(MDC)

Isaninnovativedatacentervirtualizationsolutionthatenablesmulti-tenancy,givingcustomerstheabilitytovirtualizeaphysicalswitchintomultiplelogicaldevices,witheachlogicalswitchhavingitsowntenants

•HPEthernetVirtualInterconnect(EVI)

IsanHPVirtualApplicationNetworkinnovationthatprovidesaLayer2extensionacrossthedatacentertosimplifytheinterconnectivityofgeographicallydispersedatacenters

•NEWDataCenterBridging(DCB)protocols

ProvidesupportforIEEE802.1QazDataCenterBridgingExchange(DCBX),EnhancedTransmissionSelection(ETS),andIEEE802.1QbbPriorityFlowControl(PFC)forconvergedfabrics

•NEWFibreChanneloverEthernet(FCoE)features

DeliversupportforFCoE,includingexpansion,fabric,trunkVFandNports,andaggregationofE-portandN-portvirtualization

•Acceleratedperformancewithjumboframes

Forintra-data-centercommunication,orfordatacentertodatacentertraffic(disasterrecovery),reducingtheamountoftimerequiredfordatabackupandrecovery

•Networkloadbalancing(NLB)multicastARP

Microsoft®NLBco-workswithmulticastARPtoprovideserverswithloadbalancingandfaultswitchover,whichlowerscostsandinvestment

Page 3: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

3

Data sheet | HP 12500 Switch Series

Software-defined networking•NEWSupportsOpenFlow1.3specifications

ToenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths

Performance•NEWHighperformancedesignwithnonblockinganddistributedClosarchitecture

Deliversupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot

•NEWHigh-density1/10/40/100GbEinterfaceconnectivity

Offersupto18interfacemoduleslotstoscaleupto8641GbEor1/10GbEor28840GbEor72100GbEports

•Hardware-basedwirespeedaccesscontrollists(ACLs)

Helpprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation

•High-performanceprocessorsystem

Thesupervisormoduleusesthreedifferentprocessorstoisolatekeytasks:controlplane(STP,OSPF,BGP,MPLS,etc.),fastrecoveryprotocols(RRPP,BFD,etc.),andchassismanagement(temperature,power,etc.)

Product architecture•Distributedarchitecturewithseparationofdataandcontrolplanes

Deliversenhancedfaulttoleranceandfacilitatescontinuousoperationandzeroservicedisruptionduringplannedorunplannedcontrol-planeevents

•AdvancedComwaremodularOS

Bringsmodularity,enhancedserviceability,stabilityandindependentprocessmonitoringthroughmodernComwarev7OperatingSystem

•In-ServiceSoftwareUpgrade(ISSU)

Providesanupgradeoftheentirechassis,oranindividualtaskorprocess,withzeropacketloss

Page 4: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

4

Data sheet | HP 12500 Switch Series

Resiliency and high availability•IntelligentResilientFramework(IRF)

Createsvirtualresilientswitchingfabrics,wheretwoormoreswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;caneliminatetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation

•Ultrafastprotocolconvergence

EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRP,MPLS,andIRF

•DeviceLinkDetectionProtocol(DLDP)

Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks

•Completesetofroutingprotocols(Layer3IPv4andIPv6)

SupportingwiderangeofroutingprotocolsincludingRIP,OSPF,IS-IS,andBGPforbothIPv4andIPv6alongwithcompletesupportofPIM-DM,PIM-SM,PIM-SSM,andMSDP

•Hotpatching

The12500SwitchSeriessupportshotpatching,allowingin-servicepatchingforsomeisolatedsoftwareproblems

•NonStopForwarding/GracefulRestart(NSF/GR)

Usingstandardized-basedIETFprotocols,the12500SwitchSeriesprovidesnonstopforwarding(switching/routing)forLayer3routingprotocols(controlplane–OSPF,BGP,andMPLS),providinghitlessfailover

•Fullyredundantandhotswappablecomponents

Providingfullhardwareredundancyforeachcomponentincludingpowersupplies,fantrays,supervisormodules,andfabricmodulestoenablethehighestlevelofavailability

•RapidRingProtectionProtocol(RRPP)

ProvidesfastrecoveryforringEthernet-basedtopology

Page 5: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

5

Data sheet | HP 12500 Switch Series

Quality of Service (QoS)•VirtualOutputQueue(VOQ)

Preventshead-of-line(HOL)blockingandgracefullyhandlesburstydatacentertrafficincreasingswitchperformance

•IEEE802.1pprioritization

Deliversdatatodevicesbasedonthepriorityandtypeoftraffic

•Layer4prioritization

EnablesprioritizationbasedonTCP/UDPportnumbers

•Broadcastcontrol

Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic

•Advancedclassifier-basedQoS

ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorper-VLANbasis

•Bandwidthshaping

– Port-basedratelimiting

Providesper-portingress-/egress-enforcedmaximumbandwidth

– Classifier-basedratelimiting

UsesACLstoenforcemaximumbandwidthforingress/egresstrafficoneachport

Compartmentalization•Departmentprotection

Usingnetworkvirtualizationstandards(QinQ,VRF,andMPLS),the12500SwitchSeriesallowsorganizationstoisolatedifferentbusinessunitswithdifferentresources(VRFs);usingstandard-basedmechanisms,thenetworkiscompletelyvirtualized,reducingcostandoperations

•IEEE802.1ahProviderBackboneBridge(MACinMAC)

ProviderBackboneBridge(PBB)isaLayer2VPNtechnologythatallowsacompleteseparationofcustomerandproviderdomainsbysealingtheuserMACintheserviceproviderMAC,whichenhancesthescalabilityofanEthernetnetwork

Page 6: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

6

Data sheet | HP 12500 Switch Series

Layer 2 switching•MultipleVLANRegistrationProtocol(MVRP)

HelpstomaintainVLANconfigurationdynamicallybasedoncurrentnetworkconfigurations

•GARPVLANRegistrationProtocol

AllowsautomaticlearninganddynamicassignmentofVLANs

•IPmulticastsnoopinganddata-drivenIGMP

AutomaticallypreventsfloodingofIPmulticasttraffic

•IEEE802.1adQinQ

IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork

•BridgeProtocolDataUnit(BPDU)tunneling

TransmitsSTPBPDUstransparently,allowingcorrecttreecalculationsacrossserviceproviders,WANs,orMANs

•VLANsupportandtagging

SupportsIEEE802.1Q(4KVLANIDs)

•SpanningTree

The12500SwitchSeriessupportstheentiresetofSTPprotocols(STP,RSTP,andMSTP),facilitatingacompleteintegrationwithstandardnetworks

Layer 3 routing•Layer3IPv4routing

ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,IS-IS,andBGP

•RIPandRIPngsupport

ProvidescompletesupportofRIPforbothIPv4andIPv6

•OSPFandOSPFv3support

ProvidescompletesupportofOSPFforbothIPv4andIPv6

•IS-ISandIS-ISv6support

ProvidescompletesupportofIS-ISforbothIPv4andIPv6

•Equal-CostMultipath(ECMP)

Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth

•Layer3IPv6routing

ProvidesroutingofIPv6atmediaspeed;supportsstaticroutes,RIPng,OSPFv3,IS-ISv6,andBGP4+

•IPv6tunneling

AllowsasmoothtransitionfromIPv4toIPv6byencapsulatingIPv6trafficoveranexistingIPv4infrastructure

Page 7: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

7

Data sheet | HP 12500 Switch Series

•Completemulticastprotocolstack

PIM-DM,PIM-SM,PIM-SSM,MSDP,andextensionstoBGPprovideoneofthemostcompletemulticastprotocolstacks

•Policyrouting

Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies

•MPLSsupport

ProvidesextendedsupportofMPLS,includingMPLSVPNsandMPLSTrafficEngineering(MPLSTE)

•VPLSsupport

ProvidesextendedsupportofVPLSfordatacentertodatacentercommunicationatLayer2;providessupportofhierarchicalVPLSforscalability

Management•sFlow

Providesscalable,ASIC-basednetworkmonitoringandaccounting;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes

•IEEE802.1abLLDPdiscovery

Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•USBsupport

– Filecopy

AllowsuserstocopyswitchfilestoandfromaUSBflashdrive

•Multipleconfigurationfiles

Storeseasilytotheflashimage

•Command-lineinterface(CLI)

Providesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility

•Logging

ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated

•Managementinterfacecontrol

Enablesordisableseachofthefollowinginterfacesdependingonsecuritypreferences:consoleport,telnetport,andSSHport

•Out-of-bandinterface

Isolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane

Page 8: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

8

Data sheet | HP 12500 Switch Series

•Networkmanagement

HPIntelligentManagementCenter(IMC)centrallyconfigures,updates,monitors,andtroubleshoots

•Networkmanagement

SNMPv2c/v3MIB-IIwithtraps

•RADIUSaccounting

Logsallsessiondetailsthatcanbeusedtogenerateusagereportsorinterfacetoabillingsystem

•RMON

Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents

•RemoteIntelligentMirroring

MirrorsingressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork

Connectivity•IPv6nativesupport

– IPv6host

EnablesswitchestobemanagedanddeployedattheIPv6network’sedge

– Dualstack(IPv4andIPv6)

TransitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols

– MulticastListenerDiscovery(MLD)snooping

ForwardsIPv6multicasttraffictotheappropriateinterface

– IPv6ACL/QoS

SupportsACLandQoSforIPv6networktraffic,preventingtrafficflooding

– IPv6routing

SupportsIPv6staticroutesandIPv6versionsofRIPandOSPFroutingprotocols

Page 9: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

9

Data sheet | HP 12500 Switch Series

Security•ControlPlanePolicing(CoPP)

ProtectionagainstDoSattacksatinfrastructureroutersandswitches;easeofconfigurationforcontrolplanepolicies

•IEEE802.1XandRADIUSnetworklogins

Controlsport-basedaccessforauthenticationandaccountability

•SecureFTP

Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile

•Switchmanagementlogonsecurity

HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication

•DHCPprotection

BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks

•DynamicARPprotection

BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata

•SecureShell(SSHv2)

Encryptsalltransmitteddataforsecure,remoteCLIaccessoverIPnetworks

•Securemanagementaccess

Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2andSNMPv3

•ACLs

ProvideIPv4andIPv6filteringbasedonsource/destinationIPaddress/subnetandsource/destinationTCP/UDPportnumber

•Mediaaccesscontrol(MAC)authentication

Providessimpleauthenticationbasedonauser’sMACaddress;supportslocalorRADIUS-basedauthentication

Convergence•Layers2,3,and4QoSmechanisms

SupportDiffServprioritytaggingbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,andsourceport

•IPmulticastsnoopinganddata-drivenIGMP

AutomaticallypreventfloodingofIPmulticasttraffic

•LLDP-MED

Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones

•InternetGroupManagementProtocol(IGMP)

UtilizesAny-SourceMulticast(ASM)orSource-SpecificMulticast(SSM)tomanageIPv4multicastnetworks;supportsIGMPv1,v2,andv3

•ProtocolIndependentMulticast(PIM)

DefinesmodesofInternetIPv4andIPv6multicastingtoallowone-to-manyandmany-to-manytransmissionofinformation;supportsPIMDenseMode(DM),SparseMode(SM),andSource-SpecificMode(SSM)

Page 10: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

10

Data sheet | HP 12500 Switch Series

•MulticastSourceDiscoveryProtocol(MSDP)

AllowsmultiplePIM-SMdomainstointeroperate;isusedforinter-domainmulticastapplications

•MulticastVLAN

AllowsmultipleVLANstoreceivethesameIPv4orIPv6multicasttraffic,lesseningnetworkbandwidthdemandbyreducingoreliminatingmultiplestreamstoeachVLAN

Monitor and diagnostics•Portmirroring

Enablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring

•Connectivityfaultdetection(IEEE802.1ag)

Connectivityfaultdetection(CFD)providesaLayer2linkOperations,Administration,andMaintenance(OAM)mechanismusedforlinkconnectivitydetectionandfaultlocating

Integration•12500VPN20Gb/sFirewallModule

Providesenhancedstatefulpacketinspectionandfiltering;supportsflexiblesecurityzonesandvirtualfirewallcontainment;deliversadvancedVPNserviceswith3DESandAESencryptionathighperformanceandlowlatency;offersWebcontentfilteringandapplicationprioritizationandoptimization

Investment protection•Modularswitchfabric

Providesinvestmentprotectionbyenablingfutureperformanceupgradesandincreasedportdensity

•Environmentallyfriendly

ROHSsupportandlowpowerconsumptionbasedonthelatesttechnologyprovideoutstandingpowerefficiency

Warranty and support•1-yearwarranty

Advancehardwarereplacementwith10-calendar-daydelivery(availableinmostcountries)

•Electronicandtelephonesupport

Limitedelectronicandbusiness-hourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/warrantysummary.

•Softwarereleases

Tofindsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/warrantysummary.

Page 11: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

11

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

I/O ports and slots 4openmoduleslots

Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination

4openmoduleslots

Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination

8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

4switchfabricslots

2MPU(formanagementmodules)slots

4switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)(10Uheight)

132.28lb(60kg)

220.46lb(100kg)

17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)

132.28lb(60kg)

220.46lb(100kg)

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

1920Mpps

3240Gb/s

1920Mpps

3240Gb/s

3840Mpps

6120Gb/s

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

HP 12500 Switch Series

Specifications

Page 12: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

12

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

Electrical characteristics

Frequency

Description

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

8123BTU/hr(8569.77kJ/hr)

100-120/200-240VAC

2380W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

8123BTU/hr(8569.77kJ/hr)

-48to-60VDC

2380W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60HzAchievedMiercomCertifiedGreenAward

10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.

14587BTU/hr(15389.29kJ/hr)

100-120/200-240VAC

4750W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Page 13: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

13

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

Page 14: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

14

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

I/O ports and slots 8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

3840Mpps

6120Gb/s

8640Mpps

13.3Tb/s

8640Mpps

13.3Tb/s

HP 12500 Switch Series

Specifications (continued)

Page 15: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

15

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

Electrical characteristics

Frequency

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

14587BTU/hr(15389.29kJ/hr)

-48to-60VDC

4750W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz

32859BTU/hr(34666.24kJ/hr)

100-120/200-240VAC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

32859BTU/hr(34666.24kJ/hr)

-48to-60VDC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Page 16: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

16

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

Page 17: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

17

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

I/O ports and slots 8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x38.39(h)in(44.2x74.0x97.51cm)(22Uheight)

242.51lb(110kg)

374.78lb(170kg)

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

4800Mpps

10.8Tb/s

4800Mpps

10.8Tb/s

HP 12500 Switch Series

Specifications (continued)

Page 18: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

18

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

Electrical characteristics

Frequency

Description

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

AchievedMiercomCertifiedGreenAward

10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.

14587BTU/hr(15389.29kJ/hr)

100-120/200-240VAC

4750W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

14587BTU/hr(15389.29kJ/hr)

-48to-60VDC

4750W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Page 19: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

19

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

Page 20: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

20

Data sheet | HP 12500 Switch Series

HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)

I/O ports and slots 18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

10.8Bpps

24.3Tb/s

10.8Bpps

24.3Tb/s

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

HP 12500 Switch Series

Specifications (continued)

Page 21: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

21

Data sheet | HP 12500 Switch Series

HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)

Electrical characteristics

Frequency

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

32859BTU/hr(34666.24kJ/hr)

100-120/200-240VAC

10700W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

32859BTU/hr(34666.24kJ/hr)

-48to-60VDC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

Page 22: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

22

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

BGP RFC1657DefinitionsofManagedObjectsforBGPv4

RFC1771BGPv4

RFC1772ApplicationoftheBGP

RFC1773ExperiencewiththeBGP-4Protocol

RFC1774BGP-4ProtocolAnalysis

RFC1997BGPCommunitiesAttribute

RFC1998PPPGandalfFZACompressionProtocol

RFC2385BGPSessionProtectionviaTCPMD5

RFC2439BGPRouteFlapDamping

RFC2796BGPRouteReflection

RFC2842CapabilityAdvertisementwithBGP-4

RFC2858BGP-4Multi-ProtocolExtensions

RFC2918RouteRefreshCapability

Denial of service protection RFC2267NetworkIngressFiltering AutomaticFilteringofwellknownDenialofServicePackets

CPUDoSProtection

RateLimitingbyACLs

Device management RFC1155StructureandMgmtInformation(SMIv1)

RFC1157SNMPv1/v2c

RFC1305NTPv3

RFC1945HypertextTransferProtocol—HTTP/1.0

RFC2452MIBforTCP6

RFC2454MIBforUDP6

RFC2573(SNMPv3Applications)

RFC2578-2580SMIv2

RFC2579(SMIv2TextConventions)

RFC2580(SMIv2Conformance)

RFC2819(RMONgroupsAlarm,Event,HistoryandStatisticsonly)

RFC2819RMON

RFC3417(SNMPTransportMappings)SNMPv3andRMON

RFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+

General protocols IEEE802.1adQ-in-Q

IEEE802.1agServiceLayerOAM

IEEE802.1ahProviderBackboneBridges

IEEE802.1DMACBridges

IEEE802.1pPriorityIEEE802.1QVLANs

IEEE802.1sMultipleSpanningTrees

IEEE802.1vVLANclassificationbyProtocolandPort

IEEE802.1wRapidReconfigurationofSpanningTree

IEEE802.1XPAE

IEEE802.3ab1000BASE-T

IEEE802.3adLinkAggregation(LAG)

IEEE802.3ae10-GigabitEthernet

IEEE802.3ahEthernetinFirstMileoverPointtoPointFiber-EFMF

IEEE802.3ba40and100GigabitEthernetArchitecture

IEEE802.3i10BASE-T

IEEE802.3u100BASE-X

IEEE802.3xFlowControl

IEEE802.3z1000BASE-X

RFC768UDP

RFC783TFTPProtocol(revision2)

RFC791IP

RFC792ICMP

RFC793TCP

RFC826ARP

RFC854TELNET

RFC868TimeProtocol

RFC903RARP

RFC951BOOTP

RFC959FileTransferProtocol(FTP)

RFC1027ProxyARP

RFC1042IPDatagrams

RFC1350TFTPProtocol(revision2)

RFC1519CIDR

RFC1542BOOTPExtensions

RFC1812IPv4Routing

RFC2131DHCP

RFC2338VRRP

RFC2784GenericRoutingEncapsulation(GRE)

RFC2865RemoteAuthenticationDialInUserService(RADIUS)

IP multicast RFC1112IGMP

RFC2236IGMPv2

RFC2283MultiprotocolExtensionsforBGP-4

RFC2362PIMSparseMode

RFC2934ProtocolIndependentMulticastMIBforIPv4

RFC3376IGMPv3

RFC3618MulticastSourceDiscoveryProtocol(MSDP)

RFC4601PIMSparseMode

Page 23: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

23

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

IPv6 RFC1350TFTP

RFC1981IPv6PathMTUDiscovery

RFC2080RIPngforIPv6

RFC2460IPv6Specification

RFC2461IPv6NeighborDiscovery

RFC2462IPv6StatelessAddressAuto-configuration

RFC2463ICMPv6

RFC2473GenericPacketTunnelinginIPv6

RFC2475IPv6DiffServArchitecture

RFC2529TransmissionofIPv6PacketsoverIPv4

RFC2710MulticastListenerDiscovery(MLD)forIPv6

RFC2740OSPFv3forIPv6

RFC2893TransitionMechanismsforIPv6HostsandRouters

RFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)

RFC3315DHCPv6(clientonly)

RFC3484DefaultAddressSelectionforIPv6RFC3513IPv6AddressingArchitecture

RFC3587IPv6GlobalUnicastAddressFormat

RFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6

RFC4251SSHv6Architecture

RFC4252SSHv6Authentication

RFC4253SSHv6TransportLayer

RFC4254SSHv6Connection

RFC4541IGMP&MLDSnoopingSwitch

RFC4862IPv6StatelessAddressAuto-configuration

MIBs IEEE8023-LAG-MIB

RFC1213MIBII

RFC1229InterfaceMIBExtensions

RFC1286BridgeMIB

RFC1493BridgeMIB

RFC1573SNMPMIBII

RFC1643EthernetMIB

RFC1657BGP-4MIB

RFC1724RIPv2MIB

RFC1757RemoteNetworkMonitoringMIB

RFC1850OSPFv2MIB

RFC2011SNMPv2MIBforIP

RFC2012SNMPv2MIBforTCP

RFC2013SNMPv2MIBforUDP

RFC2021RMONv2MIB

RFC2096IPForwardingTableMIB

RFC2233InterfacesMIB

RFC2273SNMP-NOTIFICATION-MIB

RFC2452IPV6-TCP-MIB

RFC2454IPV6-UDP-MIB

RFC2465IPv6MIB

RFC2466ICMPv6MIB

RFC2571SNMPFrameworkMIB

RFC2572SNMP-MPDMIB

RFC2573SNMP-TargetMIB

RFC2613SMONMIB

RFC2618RADIUSClientMIB

RFC2620RADIUSAccountingMIB

RFC2665Ethernet-Like-MIB

RFC2674802.1pandIEEE802.1QBridgeMIB

RFC2737EntityMIB(Version2)

RFC2787VRRPMIB

RFC2819RMONMIB

RFC2863TheInterfacesGroupMIB

RFC2925PingMIB

RFC2932IP(MulticastRoutingMIB)

RFC2933IGMPMIB

RFC3273HC-RMONMIB

RFC3414SNMP-Userbased-SMMIB

RFC3415SNMP-Viewbased-ACMMIB

RFC3418MIBforSNMPv3

RFC3621PowerEthernetMIB

RFC3813MPLSLSRMIB

RFC3814MPLSFTNMIB

RFC3815MPLSLDPMIB

RFC3826AESforSNMP’sUSMMIB

RFC4133EntityMIB(Version3)

LLDP-EXT-DOT1-MIB

LLDP-EXT-DOT3-MIB

LLDP-MIB

MPLS RFC2205ResourceReSerVationProtocol(RSVP)-Version1FunctionalSpecification

RFC2209ResourceReSerVationProtocol(RSVP)

RFC2702RequirementsforTrafficEngineeringOverMPLS

RFC2858MultiprotocolExtensionsforBGP-4

RFC3031MultiprotocolLabelSwitchingArchitecture

RFC3032MPLSLabelStackEncoding

RFC3036LDPSpecification

RFC3107CarryingLabelInformationinBGP-4

RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnels

RFC3479FaultTolerancefortheLabelDistributionProtocol(LDP)

RFC3487GracefulRestartMechanismforLDP

RFC4090FastRerouteExtensionstoRSVP-TEforLSPTunnels

RFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)

RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailures

RFC4447PseudowireSetupandMaintenanceUsingLDP

RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworks

RFC4664FrameworkforLayer2VirtualPrivateNetworks

RFC4665ServiceRequirementsforLayer2ProviderProvisionedVirtualPrivateNetworks

RFC4761VirtualPrivateLANService(VPLS)UsingBGPforAuto-DiscoveryandSignaling

RFC4762VirtualPrivateLANService(VPLS)UsingLabelDistributionProtocol(LDP)Signaling

Page 24: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

24

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

IEEE802.1D(STP)

RFC1155StructureofManagementInformation

RFC1157SNMPv1

RFC1215SNMPGenerictraps

RFC1757RMON4groups:Stats,History,AlarmsandEvents

RFC1905SNMPv2ProtocolOperations

RFC2211Controlled-LoadNetwork

RFC2272SNMPv3ManagementProtocolRFC2273SNMPv3Applications

RFC2274USMforSNMPv3

RFC2571SNMPManagementFrameworksRFC2572SNMPv3MessageProcessing

RFC2573SNMPv3Applications

RFC2576CoexistencebetweenSNMPversions

RFC2578SMIv2

RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm)and9(events)

RFC3164BSDsyslogProtocol

RFC3415SNMPv3View-basedAccessControlModelVACM)

ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

SNMPv1/v2c/v3

OSPF RFC1245OSPFprotocolanalysis

RFC1246ExperiencewithOSPF

RFC1587OSPFNSSA

RFC1765OSPFDatabaseOverflow

RFC1850OSPFv2ManagementInformationBase(MIB),traps

RFC2328OSPFv2

RFC2370OSPFOpaqueLSAOption

RFC3101OSPFNSSA

RFC3623GracefulOSPFRestart

QoS/CoS IEEE802.1P(CoS)

RFC2212GuaranteedQualityofService

RFC2474DSFieldintheIPv4andIPv6Headers

RFC2475DiffServArchitecture

RFC2597DiffServAssuredForwarding(AF)

RFC2598DiffServExpeditedForwarding(EF)

RFC2697ASingleRateThreeColorMarker

RFC2698ATwoRateThreeColorMarkerBi-directionalRateShaping

Security IEEE802.1AEMACSecurityStandard(MACSec)

IEEE802.1XPortBasedNetworkAccessControl

RFC1321TheMD5Message-DigestAlgorithmRFC2082RIP-2MD5Authentication

RFC2104Keyed-HashingforMessageAuthentication

RFC2716PPPEAPTLSAuthenticationProtocol

RFC2865RADIUSAuthentication

RFC2866RADIUSAccounting

RFC2867RADIUSAccountingModificationsforTunnelProtocolSupport

RFC2868RADIUSAttributesforTunnelProtocolSupport

RFC2869RADIUSExtensions

RFC3567IntermediateSystem(IS)toISCryptographicAuthentication

AccessControlLists(ACLs)

GuestVLANfor802.1x

MACAuthentication

SSHv2SecureShell

WebAuthentication

IKEv1 RFC2865—RemoteAuthenticationDialInUserService(RADIUS)

Page 25: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

25

Data sheet | HP 12500 Switch Series

HP 12500 Switch Series accessories

Modules NEWHPFlexFabric12500EMainProcessingUnit(JG802A)

HP12500TypeAMainProcessingUnitwithComwarev7OperatingSystem(JG497A)

HP12500MainProcessingUnit(JC072B)

NEWHPFlexFabric125004-port100GbECFPFDModule(JG786A)

NEWHPFlexFabric125004-port100GbECFPFGModule(JG788A)

NEWHPFlexFabric1250016-port40GbEQSFP+FDModule(JG790A)

NEWHPFlexFabric1250048-port1/10GbESFP+FDModule(JG796A)

NEWHPFlexFabric1250040-port1/10GbESFP+FDModule(JG792A)

NEWHPFlexFabric1250040-port1/10GbESFP+FGModule(JG794A)

HP1250016-port10GbESFP+LEBModule(JC782A)

HP1250016-port10GbESFP+LECModule(JC783A)

HP1250032-port10GbESFP+REBModule(JC064B)

HP1250032-port10GbESFP+RECModule(JC476B)

HP125008-port10GbESFP+LEBModule(JC780A)

HP125008-port10GbESFP+LECModule(JC781A)

HP125008-port10GbESFP+LEFModule(JC659A)

HP125008-port10GbEXFPLEBModule(JC073B)

HP125008-port10GbEXFPLECModule(JC068B)

HP1250048-portGig-TLEBModule(JC074B)

HP1250048-portGig-TLECModule(JC065B)

HP1250048-portGbESFPLEBModule(JC075B)

HP1250048-portGbESFPLECModule(JC069B)

HP1250048-portGbESFPLEFModule(JC660A)

HP12500PowerMonitorModule(JC502A)

Page 26: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

26

Data sheet | HP 12500 Switch Series

Transceivers HPX120100M/1GSFPLCLXTransceiver(JF832A)

HPX114100MSFPLCFXTransceiver(JF833A)

HPX1251GSFPLCLH401310nmTransceiver(JD061A)

HPX1201GSFPLCLH401550nmTransceiver(JD062A)

HPX1251GSFPLCLH70Transceiver(JD063B)

HPX1201GSFPRJ45TTransceiver(JD089B)

HPX1201GSFPLCBX10-UTransceiver(JD098B)

HPX1201GSFPLCBX10-DTransceiver(JD099B)

HPX1201GSFPLCLH100Transceiver(JD103A)

HPX1701GSFPLCLH701550Transceiver(JD109A)

HPX1701GSFPLCLH701570Transceiver(JD110A)

HPX1701GSFPLCLH701590Transceiver(JD111A)

HPX1701GSFPLCLH701610Transceiver(JD112A)

HPX1701GSFPLCLH701470Transceiver(JD113A)

HPX1701GSFPLCLH701490Transceiver(JD114A)

HPX1701GSFPLCLH701510Transceiver(JD115A)

HPX1701GSFPLCLH701530Transceiver(JD116A)

HPX1201GSFPLCSXTransceiver(JD118B)

HPX1201GSFPLCLXTransceiver(JD119B)

HPX13010GXFPLCZRTransceiver(JD107A)

HPX13010GXFPLCLRTransceiver(JD108B)

HPX13010GXFPLCSRTransceiver(JD117B)

HPX13510GXFPLCERTransceiver(JD121A)

HPX18010GXFPLCLH80km1538.98nmDWDMTransceiver(JG226A)

HPX18010GXFPLCLH80km1539.77nmDWDMTransceiver(JG227A)

HPX18010GXFPLCLH80km1540.56nmDWDMTransceiver(JG228A)

HPX18010GXFPLCLH80km1542.14nmDWDMTransceiver(JG229A)

HPX18010GXFPLCLH80km1542.94nmDWDMTransceiver(JG230A)

HPX18010GXFPLCLH80km1558.98nmDWDMTransceiver(JG231A)

HPX18010GXFPLCLH80km1559.79nmDWDMTransceiver(JG232A)

HPX18010GXFPLCLH80km1560.61nmDWDMTransceiver(JG233A)

HPX13010GSFP+LCSRTransceiver(JD092B)

HPX13010GSFP+LCLRMTransceiver(JD093B)

HPX13010GSFP+LCLRTransceiver(JD094B)

HPX13010GSFP+LCER40kmTransceiver(JG234A)

HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)

HPX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)

HPX14040GQSFP+MPOSR4Transceiver(JG325B)

HPX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)

HPX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

NEWHPX150100GCFPLCLR410kmSMTransceiver(JG829A)

HPX13010GSFP+LCLH80kmTransceiver(JG915A)

Cables HPPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)

HPPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)

HPPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)

HPPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)

HPPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)

HPPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)

Mounting Kit HPX421ChassisUniversal4-postRackMountingKit(JC665A)

Appliance HP1250020GbpsVPNFirewallModule(JG371A)

HP 12500 Switch Series accessories (continued)

Page 27: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

27

Data sheet | HP 12500 Switch Series

Memory NEWHPFlexFabric4GBCompactFlashCard(JG806A)

NEWHPFlexFabric4GBDDR3SDRAM(JG807A)

HPX6001GCompactFlashCard(JC684A)

HP2GBRegisteredDDR2SDRAMMemory(JC609A)

HPX6101GBDDR2SDRAMMemory(JC071A)

HP 12504 AC Switch Chassis (JC654A) HP1250xG2FabricModule(JC658A)

HP12500ACPowerEntryModule(JF426A)

HP125002000WACPowerSupply(JF429A)

HP12504FanAssembly(JC664A)

HP 12504 DC Switch Chassis (JC655A) HP1250xG2FabricModule(JC658A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12504FanAssembly(JC664A)

HP 12508 AC Switch Chassis (JF431C) HP12508FabricModule(JC067B)

HP1250xG2FabricModule(JC658A)

HP12508TopandBottomCableGuidesforACPoweredSwitch(JC785A)

HP12500SideCableManagementGuide(JC084A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)HP12508FanAssembly(JC081A)

HP12508OptionalAirFilter(JC082A)

HP 12508 DC Switch Chassis (JC652A) HP12508FabricModule(JC067B)

HP1250xG2FabricModule(JC658A)

HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12508FanAssembly(JC081A)

HP12508OptionalAirFilter(JC082A)

HP 12518 AC Switch Chassis (JF430C) HP12518G2FabricModule(JC657A)

HP12518FabricModule(JC066A)

HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)

HP12500SideCableManagementGuide(JC084A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)

HP12518FanAssembly(JC080A)

HP12518OptionalAirFilter(JC083A)

HP 12518 DC Switch Chassis (JC653A) HP12518G2FabricModule(JC657A)

HP12518FabricModule(JC066A)

HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12518FanAssembly(JC080A)

HP12518OptionalAirFilter(JC083A)

HP FlexFabric 12508E AC Switch Chassis (JG782A)

NEWHPFlexFabric12508EFabricModule(JG798A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforACPoweredSwitch(JG830A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)

HP125002000WACPowerSupply(JF429A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12508EOptionalAirFilter(JG808A)

HP 12500 Switch Series accessories (continued)

Page 28: HP 12500 Switch Series - IP Trading · • Rapid Ring Protection Protocol (RRPP) Provides fast recovery for ring Ethernet-based topology. 5 Data sheet HP 12500 Switch Series Quality

RatethisdocumentSharewithcolleagues

Sign up for updates hp.com/go/getupdated

©Copyright2010-2014Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

MicrosoftisaregisteredtrademarkoftheMicrosoftgroupofcompanies.

4AA3-0666ENW,August2014,Rev.13

Datasheet|HP12500SwitchSeries

ProductswithinthisserieshaveachievedsufficientscoresineachoftheratedcriteriatoachievetheMiercomCertifiedGreendistinctionAward.SeetheSpecificationssectionofthisseriesformoreinformation.

HP FlexFabric 12508E DC Switch Chassis (JG783A)

NEWHPFlexFabric12508EFabricModule(JG798A)

HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)

HP125001800WDCPowerSupply(JC651A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12508EOptionalAirFilter(JG808A)

HP FlexFabric 12518E AC Switch Chassis (JG784A)

NEWHPFlexFabric12518EFabricModule(JG800A)

HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)

HP12500SideCableManagementGuide(JC084A)

NEWHPFlexFabric12518EOptionalExtendedCableGuideforACPoweredSwitch(JG831A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12518EOptionalAirFilter(JG809A)

HP FlexFabric 12518E DC Switch Chassis (JG785A)

NEWHPFlexFabric12518EFabricModule(JG800A)

HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

NEWHPFlexFabric12518EOptionalExtendedCableGuideforDCPoweredSwitch(JG833A)

HP125001800WDCPowerSupply(JC651A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12518EOptionalAirFilter(JG809A)

Learn more at hp.com/networking

HP 12500 Switch Series accessories (continued)