IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero Emission Datacenter Dr. G. Ingmar Meijer IBM Research – Zurich [email protected]

Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

IBM Research – Zurich

© 2011 IBM Corporation

Hotwater Cooling for Energy-Hungry Datacenters

Towards a Zero – Emission Datacenter

Dr. G. Ingmar MeijerIBM Research – [email protected]

Page 2: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

2 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Outline

1. IntroductionA. Datacenter Market Drivers and Trends B. Energy Consumption Issues

2. Hotwater Cooling; Concept3. Prototype High-Performance Computer (“First-of-a-Kind”)4. IBM System x iDataPlex Water Cooled dx360 M4

A. Direct Water CoolingB. .Power & Performance

5. Summary

Page 3: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

3 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

1.A. Datacenter Market Drivers and Trends

Total cost of ownership and environmental footprint

Servers used 330 TWh of electrical energy: €25bn or 2% of the electricity production (2009).

ICT industries carbon emission as aviation.

Page 4: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

4 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

1.B. Energy-Consumption Issues (and Thermal Issues): propagate through hardware levels

Page 5: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

5 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Energy Consumption of Transistor (Leakage Current)

Page 6: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

6 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Energy Consumption of Datacenter

Air-cooled datacenters are inefficient. Typical cooling needs as much energy as IT equipment and both are thrown-away.

Provocative: datacenter is a huge “heater with integrated logic.”

For a 10 MW datacenter €2m–€3m is wasted per year.

APC, Whitepaper #113 (2010)

Page 7: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

7 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

2. Zero – Emission Datacenter Concept

CMOS 80ºC

a. Micro-channel liquid coolersb. Heat exchangerc. Waste-heat utilization

Water 60ºC

Page 8: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

8 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Energy and Emission of Conventional Datacenter

Power Station

$$CO2

Low-grade heat Chiller Heat wasted

Page 9: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

9 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

$CO2

Zero – Emission Datacenter (CO2 < 15 % net)

Heat re-used

CO2

Medium-grade heat

$

Power Station

Page 10: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

10 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Comparison: Water Cooling vs. Air CoolingWater Cooling:

T ~ 50 – 100 KT ~ 5 – 10 K

Air Cooling:

Page 11: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

11 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Energy consumptionreduced by

up to 40%

Direct use of waste heatcuts CO2 emissions by

up to 85%World record in facility-level

efficiency in TFLOP/gCO2

7.9

3. Zero – Emission Datacenter Prototype HPC Cluster at ETH Zurich, “Aquasar”

Page 12: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

12 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Water-Cooled IBM BladeCenter QS22

Page 13: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

13 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Effective Computing Power 1.4 GFLOPS/W

Page 14: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

14 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

14

4. Leibniz Rechenzentrum, Garching, GermanySuperMUC: Warm-Water Cooled 3 PFLOPS System

1Q12—2Q12: ~10000 IBM System x iDataPlex Water Cooled dx360 M4

Page 15: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

15 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Hybrid Datacenter w/ Direct Water Cooled Nodes

Highly energy-efficient hybrid-cooling solution:– Compute racks

– 90% Heat flux to warm water– 10% Heat flux to CRAH

– Switch / Storage racks– Rear door heat exchangers

Compute node power consumption reduced ~ 10% due to lower component temperatures and no fans.

Power Usage Effectiveness PTotal / PIT: PUE ~ 1.1

Heat recovery is enabled by the compute node design: Energy Reuse Effectiveness (PTotal – PReuse) / PIT: ERE ~ 0.3

Page 16: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

16 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

IBM System x iDataPlex Water Cooled dx360 M4

Heat flux > 90% to water; very low chilled water requirement.

Power advantage over air-cooled node: warm water cooled ~10% (cold water cooled ~15%) due to lower Tcomponents and no fans.

Typical operating conditions: Tair = 25 – 35°C, Twater = 18 – 45°C.

Page 17: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

17 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

5. Main Messages / Outlook

Technology exists to design Zero – Emission Datacenter:– Hot-water cooling & Waste heat utilization

Business value / opportunity – Energy cost reduction– Performance increase – Low-carbon pioneers “world-record TFLOP/gCO2”

What is next?IBM System x iDataPlex Water Cooled dx360 M4

Supercomputing SC11 Seattle, November 12-18, 2011:– Node at IBM booth

Page 18: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

18 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

IBM Team

Aquasar– IBM Research – Zurich

– IBM Germany Research & Development

IBM System x iDataPlex Water Cooled dx360 M4 and SuperMUC– IBM Systems & Technology Group

– IBM Research – Zurich

– IBM Germany

Page 19: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

19 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Roadmap: 3D CMOS integration and Heat Removal

3D CMOS integration requires (scalable) interlayer liquid cooling

Challenge: isolate electrical interconnects from liquid Experimental heat removal on test vehicle 180 W/cm2 per layer

(extrapolated 7.2 kW from 10 layers with 4 cm2)

Page 20: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

20 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich

Page 21: Hotwater Cooling for Energy-Hungry Datacenters Workshop · IBM Research – Zurich © 2011 IBM Corporation Hotwater Cooling for Energy-Hungry Datacenters Towards a Zero – Emission

21 Hotwater Cooling for Energy-Hungry Datacenters | Towards a Zero – Emission Datacenter © 2011 IBM Corporation

IBM Research – Zurich