44
Each office is independently owned and operated. | ©2019 The HomeTeam Inspection Service, Inc. All rights reserved. HOME INSPECTION REPORT Home. Safe. Home.

HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

Each office is independently owned and operated. | ©2019 The HomeTeam Inspection Service, Inc. All rights reserved.

HOME INSPECTION REPORT

Home. Safe. Home.

Page 2: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

ACCURATE

TRUSTED

FAST

WHAT IS A HOME INSPECTION?The purpose of a home inspection is to visually examine

the readily accessible systems and components of the home.

The inspectors are not required to move personal property,

materials or any other objects that may impede access or limit

visibility. Items that are unsafe or not functioning, in the opinion

of the inspector, will be described in accordance with the

standards of practice by which inspectors abide.

WHAT DOES THIS REPORT MEAN TO YOU? This inspection report is not intended as a guarantee, warranty

or an insurance policy. Because your home is one of the largest

investments you will ever make, use the information provided in

this report and discuss the indings with your real estate agent

and family to understand the current condition of the home.

OUR INSPECTIONS EXCEED THE HIGHEST INDUSTRY STANDARDS.Because we use a team of inspectors, each an expert in his or

her ield, our inspections are performed with greater eiciency

and more expertise and therefore exceed the highest industry

standards. We are pleased to provide this detailed report as a

service to you, our client.

WE BELIEVE IN YOUR DREAM OF HOME OWNERSHIP.We want to help you get into your dream home. Therefore,

we take great pride in assisting you with this decision making

process. This is certainly a major achievement in your life. We are

happy to be part of this important occasion and we appreciate

the opportunity to help you realize your dream.

WE EXCEED YOUR EXPECTATIONS.Buying your new home is a major decision. Much hinges on the

current condition of the home you have chosen. That is why we

have developed the HomeTeam Inspection Report. Backed by

HomeTeam’s experience with hundreds of thousands of home

inspections over the years, the report in your hand has been

uniquely designed to meet and exceed the expectations of

today’s homebuyers. We are proud to deliver this high-quality

document for your peace of mind. If you have any questions

while reviewing this report, please contact us immediately.

Thank you for allowing us the opportunity to serve you.

Page 3: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

SPOKANE, WA

509.981.9664 Fax:hometeam.com/[email protected]

Tuesday, April 16, 2019

Shannon Pence

735 E 37th Ave

Spokane WA, 99203

Dear Shannon,

On 4/16/2019 HomeTeam Inspection Service made a visual inspection of the property referenced above. Enclosedplease find a written, narrative report of our findings in accordance with the terms of our Home Inspection Agreement.Although maintenance items may have been addressed verbally at the time of the inspection, they may not be includedin the enclosed report.

I trust the enclosed information is helpful and I hope you enjoy every aspect of your new home. If I can be of anyassistance, please feel free to call me at the above telephone number.

Sincerely,

Randy and Rob Jorgenson

HomeTeam Inspection Service

Home Inspector 735 & 1665

Page 1 of 42

Page 4: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

PREFACE:

This report is intended for the sole, confidential, and exclusive use and benefit of the Client(s) under a written HomeTeam InspectionAgreement. This report is not intended for the benefit of, and may not be relied upon by, any other party. The disclosure ordistribution of this report to the current owner(s) of the property inspected or to any real estate agent will not make those personsintended beneficiaries of this report. The HomeTeam Inspection Service has no liability to any party (other than the HomeTeam clientnamed above, for whom this report was expressly prepared) for any loss, damage or expense (including, without limitation, attorneyfees) arising from any claim relating to this report.

A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observationof the visible and apparent condition of the structure and its components on the date of the inspection. We will not render an opinionas to the condition of any systems or components of the structure that are concealed by walls, floors, drywall, paneling, suspendedceiling tiles, insulation, carpeting, furniture or any other items stored in or on the property at the time of the inspection.

The results of this home inspection are not intended to make any representation regarding the presence or absence of latent orconcealed defects that are not reasonably ascertainable in a competently performed home inspection. No warranty or guaranty isexpressed or implied.

If the person conducting your home inspection is not a licensed structural engineer or other professional whose license authorizesthe rendering of an opinion as to the structural integrity of a building or its other component parts, you may be advised to seekprofessional opinion as to any defects or concerns mentioned in the report. If the age, condition or operation of any system, structureor component of the property is of a concern to you, it is recommended that a specialist in the respective field be consulted for amore technically exhaustive evaluation.

This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose.

This inspection report includes a description of any material defects (*) noted during the inspection, along with any recommendationthat certain experts be retained to determine the extent of the defects and any corrective action that should be taken. Any materialdefect that poses an unreasonable risk to people on the property will be conspicuously defined as such. Any recommendations madeto consult with other specialists for further evaluation as a result of our findings should be complete prior to the conclusion of theinspection contingency period.The Client warrants they will read the entire Inspection Report when received and shall promptlycontact HomeTeam regarding any questions or concerns the Client may have regarding the inspection or the Inspection Report.

* Material Defect: A problem with a residential real property or any portion of it that would have a significant adverse impact on thevalue of the property or that involves an unreasonable risk to the people on the property. The fact that a structural element, system orsubsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself amaterial defect.

The majority of home inspections are performed on pre-existing structures. The age of these structures vary from just a few years toover 99 years old. Building techniques have changed dramatically over the years. These changes are what bring character to theneighborhoods, and affect a buyer's decision to purchase one home over another. Therefore, the age and method of construction willaffect the individual character of a home.

We will not determine the cause of any condition or deficiency, determine future conditions that may occur including the failure ofsystems and components or consequential damage or components or determine the operating costs of systems or components.

It is not uncommon to observe cracks or for cracks to occur in concrete slabs or exterior and interior walls. Cracks may be caused bycuring of building materials, temperature variations and soil movement such as: settlement, uneven moisture content in the soil,shock waves, vibrations, etc. While cracks may not necessarily affect the structural integrity of a building, cracks should be monitoredso that appropriate maintenance can be performed if movement continues at an abnormal rate. Proper foundation maintenance iskey to the prevention of initial cracks or cracks enlarging. This includes, but not limited to proper watering, foundation drainage andremoval of vegetation growth near the foundation.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 2 of 42

Page 5: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

GENERAL DESCRIPTION

Throughout this report, the terms "right" and "left" are used to describe the home as viewed from the street.

A system or component has a material defect if it is either unsafe or not functioning and cannot be replaced or renderedsafe or functional for less than $1,000. The HomeTeam inspects for evidence of structural failure and safety concernsonly. The cosmetic condition of the paint, wall covering, carpeting, window coverings, etc., are not addressed.

Routine maintenance and safety items are not within the scope of this inspection unless they otherwise constitutemajor, visually observable defects. Although some maintenance and/or safety items may be disclosed, this report doesnot include all maintenance or safety items, and should not be relied upon for such items.

All conditions are reported as they existed at the time of the inspection.

The approximate temperature at the time of the inspection was 50 to 60 degrees Fahrenheit, and the weather waspartly clear. The seller was present at the time of the inspection. The utilities were on at the time of the inspection. Theage of the home, as reported by the MLS sheet was said to be 66 years old.

• NOTE: Vintage Home Prior to 1960Vintage Homes-(Homes build prior to 1960) Character homes have inherent defects because they werebuilt without the benefit of the standardized building codes. You must keep in mind that the defects notedthroughout this report are typical. Such dwellings because of normal wear and tear throughout the years.Often, maintenance repairs are ongoing and done based on your budget. If you tried to repair or improveall at once, costs could become high to the point where it is not practical or affordable to you at this timeRepairs or improvements which you would like to repair in the immediate future or have been advised to do,should be quoted prior to purchase by qualified contractors for costs and methods of repair.

• NOTE: Lead Based Paint Before 1978It has been determined that this home was built before 1978 and therefore stands a high risk of having leadbased paint present. Not only is lead not good for your health, under the EPA ruling 40CFR part 745effective April 22nd, 2010, any renovation, remodeling or painting not performed by yourself must be doneby a certified contractor following Lead Safe Practices and this could lead to higher prices than similarcontracts performed on homes that do not have lead based paint. It is recommended that a preliminaryscreening for lead based paint be conducted to determine the likelihood of the presence of lead beforeclosing if this is a concern for you.

The inspected property consisted of a one story wood-framed structure with wood and wood shingle siding that wasoccupied at the time of the inspection. There were no material defects on the visual portions of the siding.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 3 of 42

Page 6: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 4 of 42

Page 7: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Peeling paint was noted on the wood siding, the exterior window trim and the wood soffit and fascia. In order

to preserve the life of the exterior surfaces and materials, all areas should be scraped and painted.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 5 of 42

Page 8: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Minor plant growth was observed against the home on the right and rear sides of the house. It isrecommended that all plant growth be removed at least 18 inches away from the siding to prevent possibledamage including insect infestation.

• The landscaping around the detached garage was in direct contact with the wood siding. This condition cancause water to penetrate into the wood and other absorbent materials in the home, causing wood rot and/ orinsect intrusion. The landscaping should be pulled back or the grade adjusted so that there is no earth-to-woodcontact.

• There was firewood and wood items and or debris stored next to the detached garage on the left and rearsides. It is recommended that all debris and firewood be removed atleast six feet away from the buildingstructure to prevent conducive conditions to wood destroying organisms. In addition all debris in or around thestructure poses a fire hazard.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 6 of 42

Page 9: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

LOT AND GRADE

The home was situated on a level to sloped lot. The general grade around the home appeared to be adequate to directrain water away from the foundation.

WALKWAY AND PORCHES

There was a concrete walkway leading to a concrete stoop in the front and on the right side of the home. There wasalso a concrete walkway that led to a concrete patio and wood stoop on the rear side of the home. Surface defects inwalkways develop and progress with age and are considered normal as long as they do not create a safety hazard.There were no material defects observed in the walkway or the stoops.

• NOTE: The right stoop was partly carpet covered at the time of inspection, so a complete and thoroughinspection of the porch/stoop was not possible.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 7 of 42

Page 10: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• There were cracks observed in the walkways on the front, right and rear sides of the home. It is recommendedthat these be repaired to prevent trip hazards and help prevent further deterioration.

• There was exposed and unsealed wood observed on the rear wood entry stoop/ deck. It is recommended thatall wood be kept well painted, stained or sealed to prevent damage from exposure to the elements.

There was a concrete patio located in the back of the home. There were no material defects observed in the patio.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 8 of 42

Page 11: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• There were cracks observed in the patio. It is recommended that the cracks be repaired to help prevent furthercracking and a potential future trip hazard.

DRIVEWAY

There was a concrete driveway on the right side of the home which led to the detached garage. There were moderatecracks, deterioration and uneven areas noted on the driveway. Surface defects in driveways develop and progress withage and are considered normal as long as they do not create a safety hazard. There were no material defects observedin the driveway.

• There were moderate cracks and uneven areas noted in the driveway. Most minor cracks in concrete areconsidered normal, as standard settlement is a common result in the pacific northwest over time. Most minorsettlement cracks can be easily treated with a standard concrete sealer and a basic application tool. Moderateconcrete cracks should be sealed and lifted as needed. All cracks should monitored for any change in size orcharacteristic. Contact a qualified contractor for repairs as desired.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 9 of 42

Page 12: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

ROOF

This visual roof inspection is not intended as a warranty or an estimate on the remaining life of the roof. Any roof metal,especially the flashing and valleys, must be kept well painted with a paint specially formulated for the use.

The roof was a gable design covered with asphalt/fiberglass shingles. Observation of the roof surfaces, flashing,skylights and penetrations through the roof was performed by walking on the roof.

The age of the roof covering, as reported by the visual inspection, was approximately ten to fifteen years. There weretwo layers of shingles on the roof at the time of the inspection. There was light curling and moderate surface wearobserved on the roof shingles at the time of the inspection. These conditions indicate the roof shingles were in thesecond half of their useful life.

The wood soffit and fascia was inspected and was in fair condition. There were no material defects detected on theexterior of the roof.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 10 of 42

Page 13: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Moss growth was observed on the home and garage roof(s). It is typical for roofs, especially facing north toexperience moss growth. The affected areas can be treated with a moss inhibiting solution.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 11 of 42

Page 14: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Tree branches were hanging over, or making contact with the home and garage roof(s). The trees should becut back away from the roof to avoid damage to the roofing material.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 12 of 42

Page 15: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• The garage roof had tree debris piled up in one or more areas. All pine needles and other debris should beremoved from the roof to help prevent damage to the roof shingles.

The roof drainage system consisted of vinyl gutters and downspouts which appeared to be functional at the time of theinspection. Gutters and downspouts should receive routine maintenance to prevent premature failure. There were nomaterial defects observed on the visible portions of the gutters or downspouts.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 13 of 42

Page 16: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• All of the gutters were in need of cleaning at the time of the inspection. Clogged gutters can cause roofdrainage water to drain at the base of the foundation, causing basement water problems. The gutters shouldbe cleaned.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 14 of 42

Page 17: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

There was one chimney. Observation of the chimney exterior was made from the roof. There were no material defectsobserved on the exterior.

ATTIC STRUCTURE

As with all aspects of the home inspection, attic and roof inspections are limited in scope to the visible and readily

accessible areas. Many areas of the roof are not visible from the attic especially near the base, where the largest

volume of water drains. The presence of or active status of roof leaks cannot be determined unless the conditions which

allow leaks to occur are present at the time of the inspection. Please be aware that rain alone is not always a condition

that causes a leak to reveal itself. The conditions that cause leaks to occur can often involve wind direction, the length

of time it rains, etc. The inspection does not offer or imply an opinion or warranty as to the past, present or future

possibility of roof, skylight, flashing or vent leaks.

The attic was accessed through a a scuttle in the in the basement stairwell .

The attic above the living space was insulated with loose-fill insulation, approximately eight-inches in depth.

Ventilation throughout the attic was provided by gable, soffit and static vents. The attic ventilation appeared to beadequate. A thermostatically controlled attic fan was not installed. Attic fans are not tested as part of the homeinspection.

The roof structure consisted of two-inch by four-inch wood rafters spaced 16 inches on center and wood plankssheathing.

The ceiling structure consisted of two-inch by four-inch rafters spaced 16-inches on center.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 15 of 42

Page 18: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

There was no active moisture visible in the attic space.

There were no material defects observed in the attic or roof structure.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 16 of 42

Page 19: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• The kitchen exhaust fan is discharging into the attic. Excessive moisture can build up in the insulation, creating

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 17 of 42

Page 20: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

a condition for mold growth. A duct should be installed from the fan exhaust to a roof vent.

DETACHED GARAGE

The detached one car wood framed garage with a wood and wood shingle siding exterior. The garage was located inback of the home; with vehicle access through one overhead-style door. There was one man door(s) for accessindependent of the drive-through door(s). The man door was tested and found to be functional. There were no materialdefects on the visual portions of the structure.

The garage roof was a gable design covered with asphalt/fiberglass shingles. Observation of the roof surfaces andflashing was performed from ground level with the aid of binoculars. The age of the roof covering, as reported by theseller disclosure, was approximately ten to fifteen years. There was one layer of roofing material on the garage at thetime of the inspection. There was light curling and moderate surface wear observed on the garage roofing at the time ofthe inspection. These conditions indicate the roofing was in the second half of its useful life.

This visual roof inspection is not intended as a warranty or an estimate on the remaining life of the roof. Any roof metal,especially the flashing and valleys, must be kept well painted with a paint specially formulated for the use. There wereno material defects detected on the exterior of the roof.

The roof structure consisted of two-inch by four-inch wood rafters spaced 24 inches on center and wood planks

sheathing. Because of the configuration of the framing and catwalk, which limited access, it was not possible to inspect

all areas of the garage roof structure.

There was no active moisture visible in the attic space. The absence of visible indications of moisture is not necessarily

conclusive evidence that the roof is free from leaks. The only way to be sure a roof does not leak is to inspect the

underside of the roof during a heavy rain. There were no material defects observed in the attic or roof structure.

The overhead electric service wire entered the garage on the front wall. A service sub-panel was not installed. Thevisible garage wiring consisted primarily of the Romex type and appeared to be in fair condition. There were no materialdefects observed in the detached garage's electrical system.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 18 of 42

Page 21: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• There were minor cracks in the concrete garage floor. It is recommended that all cracks be repaired to helpprevent further cracking and a potential trip hazard.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 19 of 42

Page 22: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

The Genie brand electric garage door opener was tested and found to be functional. The automatic safety reverse onthe garage door was tested and found to be functional. The functionality of remote transmitters, keyless entry or otheropening devices is not tested during the home inspection.

• The garage door button has to be continuously engaged in order for the door to close automatically. This canbe the result of dirt and or debris in line or obstructing the safety reverse photo eyes. The eyes should becleaned and adjusted and then re-tested. If general cleaning and adjustments do not remedy the problem,then it is recommended that you consult with a garage door repair technician for service and or repairs asneeded or desired.

FOUNDATION

The foundation was constructed of poured concrete. A single inspection cannot determine whether movement of afoundation has ceased. Any cracks should be monitored regularly. There were no material defects observed on thevisible portions of the foundation.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 20 of 42

Page 23: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

There were several minor, settlement cracks observed on the foundation. The cracks were 1/16-inch or less in width.These cracks are common and usually insignificant. All buildings experience some settlement. Settlement cracks mostoften occur within the first few years after construction as the soil under the structure accommodates itself to the load ofthe structure. However, the significance of cracks cannot always be judged by a single inspection. All cracks should bemonitored for significant changes in characteristics. Consult with a company specializing in foundation repair if there is amarked change in the size or dimension of a crack.

BASEMENT

The full basement was partially finished, and contained the following mechanical systems: furnace and water heater.

The basement was dry at the time of the inspection. Because the basement is below grade, there exists a vulnerabilityto moisture penetration after heavy rains. Please note that it is not within the scope of this inspection to determine orpredict the amount or frequency of past or future water intrusion into the basement. HomeTeam will make its best effortin accordance with the ASHI Standards of Practice to determine, based solely on visible conditions at the time of theinspection, whether there is any evidence of ongoing water penetration in the property. You should use all availableresources including the seller disclosure and information from the current owner to determine if any water issues exist. Ifyou require a guarantee of a 100 percent dry basement, consult with a company specializing in water proofing.

The concrete basement floor was in satisfactory condition. Minor cracks within any concrete slab are common and aremost often due to shrinkage and settlement. Concrete floors are poured after the structure is built and serve no purposewith regard to structural support.There were no material defects observed in the basement.

The basement stairway was inspected and there were no visual defects or visual safety concerns observed with thesteps, stairways or handrails.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 21 of 42

Page 24: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• NOTE: One or more small sections of the floor structure were covered with a material that has thecharacteristics of asbestos. The material did not appear to be damaged or deteriorating at the time of theinspection. It is advisable to avoid disturbing the substance prior to any testing. The only way to confirm thecontents of the material is to have a sample tested by a qualified laboratory. If the substance is of any concern,a qualified asbestos testing firm should be contacted.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 22 of 42

Page 25: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• There was not a drain present in the basement utility room. The basement should have a drain and trappresent, it is recommended that a qualified plumbing contractor be contacted for installation.

The finished basement area included a bedroom, a family room, laundry room, unity room, mechanical room andbathroom. The interior walls of the basement were finished; therefore, a complete inspection of the poured concretefoundation was not possible. There were no material defects observed on the visible portions of the foundation.

• Failure to keep walls sealed can cause deterioration and extensive moisture damage including mold growth tothe interior walls, which is not always visible at the time of the inspection. Some of the caulk was missing fromaround the base of the tub . These areas should be re-caulked to prevent moisture penetration.

• The basement toilet was loose and or not fully secured to the floor. It is recommended the toilet be properlysecured and sealed to help prevent potential leaking from movement. Contact a qualified contractor for repairsas needed.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 23 of 42

Page 26: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

FLOOR STRUCTURE

The visible floor structure consisted of a wood planking subfloor, supported by two-inch by ten -inch wood joists spacedsixteen inches on center. There was a 2x4 in wall for load bearing support. There were no material defects observed inthe visible portions of the floor structure.

PLUMBING

The visible water supply lines throughout the home were copper and galvanized pipe. The water was supplied by apublic water supply. Water valves are not tested as part of the home inspection. Water valves that have not beenoperated for an extended period of time often leak after being operated. We would not be able to repair a leaking valveduring the home inspection.

The visible waste lines consisted of cast iron, galvanized & ABS pipe. The functional drainage of the drain waste linesappeared to be adequate at the time of the inspection. The home was connected to a public sewer system. The under-floor drain lines are considered underground utilities and are specifically excluded from the inspection. The lines are not

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 24 of 42

Page 27: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

visible or accessible and their condition cannot be verified during a visible home inspection. Simply running water intofloor drains will not verify the condition of the waste line infrastructure under the home. Consult with a qualified plumberfor a camera inspection of the sewer laterals if there is any concern as to the condition of the waste lines under thehome.

All plumbing fixtures not permanently attached to a household appliance were operated and inspected for visible leaks.Water flow throughout the home was average. Water pressure was tested at an outdoor sillcock and found to be 50 to60 pounds per square inch. This report is not intended to be an exhaustive list of minor plumbing issues. Concealed,latent or intermittent plumbing issues may not be apparent during the testing period. There were no material defectsobserved in the visible portions of the plumbing system.

WATER HEATER

There was a 50 gallon capacity, electric water heater located in the basement. The water heater was manufactured byGeneral Electric, model number PE50M09AAG and serial number 0904R11482. Information on the water heater

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 25 of 42

Page 28: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

indicated that it was manufactured 15 years ago.

A temperature and pressure relief valve (T & P) was present. Because of the lime build-up typical of T & P valves, wedo not test them. An overflow leg was present. It did terminate close to the floor. Your safety depends on the presenceof a T & P valve and an overflow leg terminating close to the floor. The water heater was functional but seismicrestraints were not present.

• No seismic restraints (earthquake straps) were present. It is recommended that water heaters be doublestrapped with a heavy gauge metal for added stability. The straps should be installed on the upper third andlower third of the tank.

• NOTE: Although completely functional at the time of inspection, due to the age of the water heater (being morethen 10 years old), it could be a candidate for replacement sometime in the near future.

• There was no drip pan installed at the base of the hot water heater. It's generally recommended, and required,to install a drip pan with a drain line beneath your hot water heater tank. Especially if you water heater is inyour home or basement, where a leak could cause lots of water damage. A pan and drain could help

eliminate this possibility.

ELECTRIC SERVICE

The overhead electric service wire entered the home on the rear wall. The electric meter was located on the exteriorwall. The service entrance cable consisted of stranded copper rated for 200 amps.

• The overhead electric service wire to the home is in contact with tree branches. Tree branches should not bein contact with the electric service wire for safety reasons. It is recommended that the local power company ora qualified contractor be contacted.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 26 of 42

Page 29: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

The service wire entered a Cutler Hammer service panel, located on the basement wall with a 200 amp and 120/240volt rated capacity. The main service disconnect switch was located in the main panel. The branch circuits within thepanel were copper. These branch circuits and the circuit breaker to which they were attached appeared to beappropriately matched. The internal components of the service panel, i.e. main lugs, bus bars, etc were in goodcondition.

• Plumbing supply pipes run directly over the main electric panel. A hard plastic, vinyl or metal shield isrecommended to be installed over the panel to help prevent water intrusion into the panel in the event of apotential plumbing pipe leak.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 27 of 42

Page 30: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

The visible house wiring consisted primarily of the Romex type and appeared to be in good condition. An electricservice grounding system was installed. Service grounding requirements have changed many times over the years. Thegrounding system for a 30-year-old electric service is different from that of a 10-year-old service. The inspection doesnot attempt to verify that the grounding system or any other part of the electric service complies with current codes.

A representative number of installed lighting fixtures, switches, and receptacles located throughout the home weretested. The grounding and polarity of receptacles within six feet of plumbing fixtures, and those attached to ground faultcircuit interrupters (GFCI), if present, were also tested. The installation of GFCI protected circuits and/or outlets locatedwithin six feet of water, in unfinished basement areas, garage and the exterior of the home is a commonly acceptedpractice and required by many municipalities. All GFCI receptacles and GFCI circuit breakers should be tested monthly.There were GFCI protected circuits in the home. The present and tested GFCIs were tested and found to be functional.

• One or more three prong type outlets in the home tested as having an open ground. This means that the third

prong, also known as the ground prong is not doing its job. This is usually caused by a missing ground

connection at an electrical device in the circuit. This condition is usually easily correctable by an electrician.

Open grounds in wet locations is considered a safety issue and should be corrected. The outlets that tested

with this condition were marked with a "GREEN" dot for easy identification. Please note that we only test

outlets that are visible and readily accessible at the time of the inspection.

• One or more missing switch or outlet covers were noted in the detached garage. All switch and outlet boxes

should be properly covered to avoid a shock hazard. Electrical related repairs should be performed by a

qualified electrician.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 28 of 42

Page 31: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Two prong outlets were found in one or more locations in the home. The junction box was not fully secured at

the time of inspeciton. At the time this home was constructed, two-prong outlets were the standard

construction. Two-pronged outlets were not grounded (open-ground), and are considered to be outdated by

today's standards. In many cases, the outlets can be easily upgraded to three-prong type. In cases where the

outlets cannot be easily upgraded, the installation of GFCI's in kitchens, baths, garages, basements, outdoor

receptacles, and any other high-risk areas, will increase the overall safety of the electrical system. A qualified

electrician should be consulted when working on or updating the electrical system in your home.

The electrical service appeared to be adequate. Alarms, electronic keypads, remote control devices, landscape lighting,telephone and television, and all electric company equipment were beyond the scope of this inspection. There were nomaterial defects observed in the electrical system.

SMOKE ALARMS

There were smoke alarms found in the house. Property maintenance codes vary from area to area. Some municipalitiesrequire smoke alarms in every bedroom, while others only require them on each floor. Check with the local codeenforcement officer for the requirements in your area. For safety reasons, the smoke alarms should be tested uponoccupancy. The batteries (if any) should be replaced with new ones when you move into the house, and tested on amonthly basis thereafter.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 29 of 42

Page 32: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

There were carbon monoxide detectors found in the home. It is now required that homes with gas appliances beequipped with carbon monoxide detectors for safety reasons. The detector will alert the occupants of the home to thepresence of dangerous carbon monoxide caused by a malfunctioning gas appliance.

WINDOWS, DOORS, WALLS AND CEILINGS

A representative number of accessible windows and doors were operated and found to be functional. The primarywindows were constructed of vinyl, single hung and sliding style, with double pane glass. All exterior doors wereoperated and found to be functional. The exterior door locks should be changed or rekeyed upon occupancy. Possibleproblem areas may not be identified if the windows or doors have been recently painted. There were no major defectsobserved in the windows or doors.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 30 of 42

Page 33: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• The garage man door did not have dead bolt locks installed at the time of inspection. Although not required, forsaftey and security, it is recommended that all exterior doors should have a deadbolt or a secondary lockinstalled. Contact a qualified contractor for installation as desired.

The interior wall and ceiling surfaces were finished with drywall. The interior wall and ceiling structure consisted of woodframing. Possible problem areas may not be identified if the interior wall and ceiling surfaces have been recentlypainted. There were no material defects observed in the interior walls or ceilings.

FIRST LEVEL

The first level consisted of a living room, dining room, kitchen, two bedrooms and one full bath. The HomeTeaminspects for evidence of structural failure and safety concerns only. The cosmetic condition of the paint, wall covering,carpeting, window coverings, etc., are not addressed. There were no material defects observed on the first level.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 31 of 42

Page 34: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• The main level bathroom sink drains slowly. If a drain un-clogger does not work, then consult with a licensedplumber for repair.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 32 of 42

Page 35: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• Failure to keep walls sealed can cause deterioration and extensive moisture damage including mold growth tothe interior walls, which is not always visible at the time of the inspection. Some of the caulk was missing fromaround the base of the tub . These areas should be re-caulked to prevent moisture penetration.

KITCHEN

The visible portions of the kitchen cabinets and counter tops were in serviceable condition. The appliances were turnedon to check operational function only. No consideration is given regarding the age or components that may be worn orotherwise affected by wear and tear or use. No warranty, express or implied, is given for the continued operationalintegrity of the appliances or their components. The kitchen contained the following appliances:

The General Electric electric range was inspected and did appear to be functional. The accuracy of the clock, timersand settings on ovens are not within the scope of this inspection.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 33 of 42

Page 36: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

The Frigidaire refrigerator was inspected and did appear to be functional. The temperature setting and ice maker, ifpresent, are not within the scope of the inspection.

The Fridgidare dishwasher was tested and did appear to be functional.

The Badger disposal was inspected and did appear to be functional. The efficiency rating and chopping / grinding abilityof the unit is not within the scope of the inspection.

DRYER CONNECTIONS AND VENT

This note is supplied for informational purposes only, as many clients want to know the type of dryer connectionsavailable to them. A 240 volt outlet for an electric clothes dryer was installed in the laundry area. For safety reasons, noattempt was made to verify that the electrical outlet is properly wired or that power is present. Consult with a qualifiedcontractor if the desired type of connection is not available.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 34 of 42

Page 37: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

A dryer vent was installed. The visible portion of the dryer vent was inspected and appeared to be functional andadequate for venting to the exterior of the home.

FIREPLACE

There were two fireplaces in the home. The visual condition at the time of the inspection was as follows:

A wood burning fireplace was located in the living room. The damper did appear to be functional. There was visualevidence of creosote buildup in the firebox and/or chimney. There were no cracks observed in the firebox or visibleportions of the chimney.

A wood burning fireplace was located in the basement. The damper did appear to be functional. There was visualevidence of creosote buildup in the firebox and/or chimney. There were no cracks observed in the firebox or visibleportions of the chimney.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 35 of 42

Page 38: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

As with all elements of the home inspection, the fireplace inspection is not technically exhaustive. The inspectionprovides a general condition report only. The fireplace inspection does not include the interior of flues or chimneys, draftcharacteristics, chimney or firebox integrity or the adequacy of draft, airflow or makeup air. Consult with a qualified,reputable chimney and fireplace professional for a complete evaluation of the fireplace and chimney. For safetyreasons, a fireplace and the chimney or pipe to which it is vented should be cleaned and re-inspected as there may behidden defects, not fully visible at the time of the inspection. The fireplace was not tested for operation or function.

HEATING SYSTEM

The heating system was inspected by HomeTeam. Periodic preventive maintenance is recommended to keep this unitin good working condition. Annual maintenance of the heating and cooling equipment is essential for safe and efficientperformance, which will maximize the system's useful life. The results of our visual and operational inspection of theheating system is described below:

The home was heated by a General Motors- Deaco-Heat fuel oil forced air furnace, serial number F-228469, modelnumber OPG-75-LD which indicated that the unit is approximately 35 years old or more. The unit was located in thebasement of the home. It has an approximate net heating capacity of 75,000 BTUH.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 36 of 42

Page 39: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• NOTE: The furnace was not fully accessible at the time of inspection. The basement mechanical closet doorswere blocking access to the furnace, therefore a complete inspection of the furnace components could not bemade. Any commentary made on the condition of the furnace is based solely on the limited visibility of theHVAC system at the time of the inspection.

• There was no recent service record for the HVAC system at the time of inspection. It is recommended that thefurnace be serviced by a licensed HVAC contractor before continued use and on an annual basis thereafter.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 37 of 42

Page 40: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

hvac: oil

Examination of heating systems is mechanically limited since the unit cannot be dismantled to examine all of the interiorcomponents. Without removing the burners to gain complete access, and with the limited viewing area of the heatexchanger, a thorough inspection is not possible. The inspection does not include a heat-loss analysis, heating designor adequacy evaluation, energy efficiency assessment, installation compliance check, chimney flue inspection, draft testor buried fuel tank inspection.

Termination of HVAC condensate lines was raised above the floor drain or drain inlet. The condensate lines were

trapped. HVAC condensate lines must be trapped and not in contact with wet drain inlets to prevent the possible

migration of bacteria and mold into the air-handling system.

The galvanized steel venting system was adequate to exhaust the spent gases to the exterior of the home and was in

fair condition. The heating system was found to be functional.

The furnace does not appear to have been recently serviced. It is recommended that the furnace be cleaned and

serviced by a qualified contractor upon taking ownership of the property. The furnace should be serviced annually to

maintain safe and efficient operation.

A carbon monoxide detector was inserted into the main plenum just above the heat exchanger. There was no

measurable level of carbon monoxide detected at the time of the inspection

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 38 of 42

Page 41: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

There will be normal temperature variations from room to room and level to level, most noticeable between levels.Airflow throughout the house may be balanced by adjusting any dampers in the supply ducts, or by adjusting the supplyregisters. Inspection of air and duct supply system for adequacy, efficiency, capacity or uniformity of the conditioned airto the various parts of the structure is beyond the scope of the home inspection.

The disposable filter should be replaced on a regular basis to maintain the efficiency of the system. The efficiency ratingis not within the scope of this inspection.

The control for the heating and air conditioning system was a 24 volt thermostat located on the living room wall of thehome. The thermostat was manufactured by Lux and was found to be in working order.

CONDUCIVE CONDITIONS TO WDO’S

There was no visible evidence of wood destroying organisms at the time of the inspection. There were conduciveconditions present.

• Vegetation contact with siding of the home is considered a conducive condition to wood destroying organismsand should be remedied.

• Peeling paint and exposed wood is considered a conducive condition to wood destroying organisms andshould be remedied.

• There was earth to wood contact with the garage siding. All earth to wood contact should be remedied to helpprevent conducive conditions to wood destroying organisms.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 39 of 42

Page 42: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

SUMMARY:

This summary provides a simplified overview of the results of the Tuesday, April 16, 2019 inspection at 735 E 37th Ave,

Spokane, WA 99203. Be sure to read the full body of the inspection report; it contains much more detail about the

property. Any additional evaluations we'verecommended must be performed prior to the conclusion of the inspection

contingency period.

Maintenance Items

• Minor plant growth was observed against the home on the right and rear sides of the house. It isrecommended that all plant growth be removed at least 18 inches away from the siding to prevent possibledamage including insect infestation.

• Peeling paint was noted on the wood siding, the exterior window trim and the wood soffit and fascia. In order

to preserve the life of the exterior surfaces and materials, all areas should be scraped and painted.

• Tree branches were hanging over, or making contact with the home and garage roof(s). The trees should becut back away from the roof to avoid damage to the roofing material.

• Moss growth was observed on the home and garage roof(s). It is typical for roofs, especially facing north toexperience moss growth. The affected areas can be treated with a moss inhibiting solution.

• The garage roof had tree debris piled up in one or more areas. All pine needles and other debris should beremoved from the roof to help prevent damage to the roof shingles.

• All of the gutters were in need of cleaning at the time of the inspection. Clogged gutters can cause roofdrainage water to drain at the base of the foundation, causing basement water problems. The gutters shouldbe cleaned.

• There was exposed and unsealed wood observed on the rear wood entry stoop/ deck. It is recommended thatall wood be kept well painted, stained or sealed to prevent damage from exposure to the elements.

• There was no recent service record for the HVAC system at the time of inspection. It is recommended that thefurnace be serviced by a licensed HVAC contractor before continued use and on an annual basis thereafter.

• The main level bathroom sink drains slowly. If a drain un-clogger does not work, then consult with a licensedplumber for repair.

• Failure to keep walls sealed can cause deterioration and extensive moisture damage including mold growth tothe interior walls, which is not always visible at the time of the inspection. Some of the caulk was missing fromaround the base of the tub . These areas should be re-caulked to prevent moisture penetration.

• Failure to keep walls sealed can cause deterioration and extensive moisture damage including mold growth tothe interior walls, which is not always visible at the time of the inspection. Some of the caulk was missing fromaround the base of the tub . These areas should be re-caulked to prevent moisture penetration.

Minor Defects

• There were moderate cracks and uneven areas noted in the driveway. Most minor cracks in concrete areconsidered normal, as standard settlement is a common result in the pacific northwest over time. Most minorsettlement cracks can be easily treated with a standard concrete sealer and a basic application tool. Moderateconcrete cracks should be sealed and lifted as needed. All cracks should monitored for any change in size orcharacteristic. Contact a qualified contractor for repairs as desired.

• There were cracks observed in the patio. It is recommended that the cracks be repaired to help prevent furthercracking and a potential future trip hazard.

• The landscaping around the detached garage was in direct contact with the wood siding. This condition cancause water to penetrate into the wood and other absorbent materials in the home, causing wood rot and/ orinsect intrusion. The landscaping should be pulled back or the grade adjusted so that there is no earth-to-woodcontact.

• There was firewood and wood items and or debris stored next to the detached garage on the left and rearsides. It is recommended that all debris and firewood be removed atleast six feet away from the buildingstructure to prevent conducive conditions to wood destroying organisms. In addition all debris in or around thestructure poses a fire hazard.

• There was not a drain present in the basement utility room. The basement should have a drain and trappresent, it is recommended that a qualified plumbing contractor be contacted for installation.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 40 of 42

Page 43: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

• The garage door button has to be continuously engaged in order for the door to close automatically. This canbe the result of dirt and or debris in line or obstructing the safety reverse photo eyes. The eyes should becleaned and adjusted and then re-tested. If general cleaning and adjustments do not remedy the problem,then it is recommended that you consult with a garage door repair technician for service and or repairs asneeded or desired.

• The kitchen exhaust fan is discharging into the attic. Excessive moisture can build up in the insulation, creatinga condition for mold growth. A duct should be installed from the fan exhaust to a roof vent.

• There was no drip pan installed at the base of the hot water heater. It's generally recommended, and required,to install a drip pan with a drain line beneath your hot water heater tank. Especially if you water heater is inyour home or basement, where a leak could cause lots of water damage. A pan and drain could help

eliminate this possibility.• There were minor cracks in the concrete garage floor. It is recommended that all cracks be repaired to help

prevent further cracking and a potential trip hazard.

• Two prong outlets were found in one or more locations in the home. The junction box was not fully secured at

the time of inspeciton. At the time this home was constructed, two-prong outlets were the standard

construction. Two-pronged outlets were not grounded (open-ground), and are considered to be outdated by

today's standards. In many cases, the outlets can be easily upgraded to three-prong type. In cases where the

outlets cannot be easily upgraded, the installation of GFCI's in kitchens, baths, garages, basements, outdoor

receptacles, and any other high-risk areas, will increase the overall safety of the electrical system. A qualified

electrician should be consulted when working on or updating the electrical system in your home.

• The basement toilet was loose and or not fully secured to the floor. It is recommended the toilet be properlysecured and sealed to help prevent potential leaking from movement. Contact a qualified contractor for repairsas needed.

• Plumbing supply pipes run directly over the main electric panel. A hard plastic, vinyl or metal shield isrecommended to be installed over the panel to help prevent water intrusion into the panel in the event of apotential plumbing pipe leak.

• There were cracks observed in the walkways on the front, right and rear sides of the home. It is recommendedthat these be repaired to prevent trip hazards and help prevent further deterioration.

Safety Concerns

• The overhead electric service wire to the home is in contact with tree branches. Tree branches should not bein contact with the electric service wire for safety reasons. It is recommended that the local power company ora qualified contractor be contacted.

• One or more three prong type outlets in the home tested as having an open ground. This means that the third

prong, also known as the ground prong is not doing its job. This is usually caused by a missing ground

connection at an electrical device in the circuit. This condition is usually easily correctable by an electrician.

Open grounds in wet locations is considered a safety issue and should be corrected. The outlets that tested

with this condition were marked with a "GREEN" dot for easy identification. Please note that we only test

outlets that are visible and readily accessible at the time of the inspection.

• No seismic restraints (earthquake straps) were present. It is recommended that water heaters be doublestrapped with a heavy gauge metal for added stability. The straps should be installed on the upper third andlower third of the tank.

• The garage man door did not have dead bolt locks installed at the time of inspection. Although not required, forsaftey and security, it is recommended that all exterior doors should have a deadbolt or a secondary lockinstalled. Contact a qualified contractor for installation as desired.

• One or more missing switch or outlet covers were noted in the detached garage. All switch and outlet boxes

should be properly covered to avoid a shock hazard. Electrical related repairs should be performed by a

qualified electrician.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 41 of 42

Page 44: HOME INSPECTION REPORT · 2019-04-16 · This home inspection report is not to be construed as an appraisal and may not be used as such for any purpose. This inspection report includes

REASONABLE EXPECTATIONS REGARDING A PROFESSIONAL HOME INSPECTION:

There may come a time when you discover something wrong with the house, and you may be upset or disappointed with your home inspection. There are somethings we'd like you to keep in mind.

Intermittent or concealed problems: Some problems can only be discovered by living in a house. They cannot be discovered during the few hours of a homeinspection. For example, some shower stalls leak when people are in the shower, but do not leak when you simply turn on the tap. Some roofs and basementsonly leak when specific conditions exist. Some problems will only be discovered when carpets are lifted, furniture is moved or finishes are removed.

No clues: These problems may have existed at the time of the inspection, but there were no clues as to their existence. Our inspections are based on the pastperformance of the house. If there are no clues of a past problem, it is unfair to assume we should foresee a future problem.

We always miss some minor things: Some say we are inconsistent because our reports identify some minor problems but not others. The minor problemsthat are identified were discovered while looking for more significant problems. We note them simply as a courtesy. The intent of the inspection is not to find the$200 problems; it is to find the $1000 problems. These are the things that affect people's decisions to purchase.

Contractor's advice: A common source of dissatisfaction with home inspectors comes from comments made by contractors. Contractors' opinions often differfrom ours. Don't be surprised when three roofers all say the roof needs replacement, when we said that the roof would last a few more years with some minorrepairs.

"Last man in" theory: While our advice represents the most prudent thing to do, many contractors are reluctant to undertake these repairs. This is because ofthe "last man in" theory. The contractor fears that if he is the last person to work on the roof, he will get blamed if the roof leaks, regardless of whether or not theroof leak is his fault. Consequently, he won't want to do a minor repair with high liability, when he could re-roof the entire house for more money and reduce thelikelihood of a callback. This is understandable.

Most recent advice is best: There is more to the "last man in" theory. It suggests that it is human nature for homeowners to believe the last bit of expert advicethey receive, even if it is contrary to previous advice. As home inspectors, we unfortunately find ourselves in the position of "first man in" and consequently it isour advice that is often disbelieved.

Why didn't we see it?: Contractors may say, "I can't believe you had this house inspected, and they didn't find this problem."There are several reasons for these apparent oversights:

• Conditions during inspection: It is difficult for homeowners to remember the circumstances in the house at the time of the inspection.Homeowners seldom remember that it was snowing, there was storage everywhere or that the furnace could not be turned on because the airconditioning was operating, etc. It's impossible for contractors to know what the circumstances were when the inspection was performed.

• This wisdom of hindsight: When the problem manifests itself, it is very easy to have 20/20 hindsight. Anybody can say that the basement iswet when there is 2" of water on the floor. Predicting the problem is a different story.

• A long look; If we spent half an hour under the kitchen sink or 45 minutes disassembling the furnace, we'd find more problems, too.Unfortunately, the inspection would take several days and would cost considerably more.

• We're generalists: We are generalists; we are not specialists. The heating contractor may indeed have more heating expertise than we do.This is because we are expected to have heating expertise and plumbing expertise, structural expertise, electrical expertise, etc.

• An invasive look: Problems often become apparent when carpets or plaster are removed, when fixtures or cabinets are pulled out, and so on.A home inspection is a visual examination. We don't perform invasive or destructive tests.

Not insurance: In conclusion, a home inspection is designed to better your odds. It is not designed to eliminate all risk. For that reason, a home inspectionshould not be considered an insurance policy. The premium that an insurance company would have to charge for a policy with no deductible, no limit and anindefinite policy period would be considerably more than the fee we charge. It would also not include the value added by the inspection.

Reprinted from ASHI Reporter, By Permission of Alan Carson, Carson Dunlop & Assoc.

File Number: 5958

Address of Inspection: 735 E 37th Ave

Page 42 of 42