27
Home Inspection 1313 Mockingbird Lane Any Town, NJ 00000 Prepared for: Satisfied Client Prepared by: Caveat Emptor Home Inspectors 14 Sterling Pl Glen Rock, New Jersey 07452

Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Home Inspection

1313 Mockingbird Lane Any Town, NJ 00000

Prepared for: Satisfied Client

Prepared by: Caveat Emptor Home Inspectors14 Sterling PlGlen Rock, New Jersey 07452

Page 2: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Table of Contents Definitions 2

General Information 2

Lots and Grounds 3

Exterior 5

Outbuilding 7

Roof 7

Garage/Carport 9

Electrical 9

Structure 11

Attic 12

Basement 13

Air Conditioning 17

Heating System 18

Plumbing 19

Bathroom 20

Kitchen 20

Bedroom 21

Living Space 22

Laundry Room/Area 23

Summary 24

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 1 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 3: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

DefinitionsNOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection

Acceptable Functional with no obvious signs of defect. Not Present Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of

inspection. Marginal Item is not fully functional and requires repair or servicing. Defective Item needs immediate repair or replacement. It is unable to perform its intended function.

General Information

Property Information

Property Address 123 Any Street City Any Town State NJ Zip 0 Contact Name Phone Fax

Client Information

Client Name Satisfied Client Client Address 456 Any Street City Any Town State NJ Zip 0 Phone 555-555-5555 Fax E-Mail email.com

Inspection Company

Inspector Name Michael T. Mulholland Company Name Caveat Emptor Home Inspectors Address 14 Sterling Pl City Glen Rock State New Jersey Zip 07452 Phone 201 689 4998 Fax 201 689-4997 E-Mail [email protected] File Number 003 Amount Received Pro Bono

Conditions

Others Present Buyer, Buyer's Agent, Buyers parents Property Occupied Occupied Estimated Age 1956 Entrance Faces North Inspection Date 12/06/2012 Start Time 2:00 End Time 4:30 Electric On Yes Gas/Oil On Yes Water On Yes Temperature 42F Weather Rain Soil Conditions Wet Space Below Grade Basement

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 2 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 4: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

General Information (Continued)Building Type Single family Garage Sewage Disposal Septic How Verified Multiple Listing Service Water Source Well How Verified Multiple Listing Service Additions/Modifications Bathroom, Roof, New deck, Kitchen Permits Obtained Unknown How Verified Buyer to verify

Lots and GroundsAcceptable Driveway: Asphalt Acceptable Walks: Concrete Marginal Steps/Stoops: Concrete Spalling cement on cheeks of platform.

Defective Porch: Wood Cement raised patio under deck is failing., A qualified contractor is recommended to evaluate and estimate repairs

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 3 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 5: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Lots and Grounds (Continued)Porch: (continued)

Marginal Deck: Treated wood No framing hangers used, Not lag bolted to house

Acceptable Grading: Marginal Vegetation: Trees Tree limbs over hang the roof and should be cut back Marginal Window Wells: Drain not present No covers

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 4 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 6: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Lots and Grounds (Continued)Defective Basement Stairwell: Concrete Stairs unsound or unsafe, A qualified contractor is recommended to

evaluate and estimate repairs

Marginal Fences: Wood, Chain link Needs replacement

ExteriorThis is a visual inspection limited in scope by (but not restricted to) the following conditions. >A representative sample of exterior components was inspected rather then every occurrence of components. >The inspection does not include an assessment of geological, geotechnical, or hydrological conditions, or environmental hazards. >Screening, shutters, awnings, or similar seasonal accessories, fences, recreational facilities, outbuildings, sea walls, break-walls, docks, erosion control, and earth stabilization measures are not inspected unless specifically agreed upon and documented in this report.

Entire Exterior Surface

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 5 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 7: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Exterior (Continued)Marginal Type: Vinyl siding

Acceptable Trim: Aluminum Acceptable Fascia: Aluminum Acceptable Soffits: Aluminum Not Inspected Door Bell: Acceptable Entry Doors: Metal, Wood Acceptable Windows: Vinyl double hung Acceptable Window Screens: Vinyl mesh Acceptable Basement Windows: Vinyl hopper, Steel hopper Need proper

caulking.

Acceptable Exterior Lighting: Surface mount Acceptable Exterior Electric Outlets: 110 VAC GFCI Acceptable Hose Bibs: Rotary

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 6 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 8: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

OutbuildingLimitations of Outbuilding Inspection With the exception of a detached garage or carport and the driveway leading to them, outbuildings are not inspected.

To rear of house Outbuilding Acceptable Exterior Surface: Wood Acceptable Roof: Asphalt shingle Acceptable Roof Structure: Rafter Acceptable Walls: Acceptable Floor: Plywood Acceptable Doors: Solid wood Acceptable Electrical: 110 VAC outlets and lighting circuits

Roof Entire Roof Surface Method of Inspection: On roof Acceptable Unable to Inspect: N/A Marginal Material: Asphalt shingle Type: Gable Approximate Age: 2 to 3 yrs old Acceptable Flashing: Acceptable Valleys: Marginal Skylights: Plastic Not suitable for low slope

application.

Acceptable Plumbing Vents: PVC Acceptable Gutters: Aluminum Acceptable Downspouts: Aluminum Acceptable Leader/Extension: Chimney

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 7 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 9: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Roof (Continued)Defective Chimney: Terra cotta Flue liner used as chimney. Chimney covered with tar,unable to inspect

masonary., A qualified contractor is recommended to evaluate and estimate repairs

Marginal Flue/Flue Cap: Clay Defective Chimney Flashing: Tar covered Improper

installation- counter flashing is not recessed into mortar joints- requires corrections

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 8 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 10: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Garage/CarportLimitations of Interior inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions >Furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block defects. >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

Attached Garage Type of Structure: Attached Car Spaces: 1 Acceptable Garage Doors: Insulated aluminum Acceptable Door Operation: Mechanized Marginal Door Opener: Overhead Door No safety reverse system in operation Acceptable Exterior Surface: Vinyl siding Acceptable Roof: Asphalt shingle Acceptable Roof Structure: 2x10 Rafter Acceptable Ceiling: Suspended ceiling Acceptable Walls: Sheetrock Marginal Floor/Foundation: Concrete block Foundation spalling. Acceptable Hose Bibs: Rotary Acceptable Electrical: 110 VAC outlets and lighting circuits Not Present Smoke Detector: Not Present Heating: Acceptable Windows: Vinyl double hung Acceptable Gutters: Aluminum Acceptable Downspouts: Aluminum Acceptable Leader/Extensions:

ElectricalLimitations of Electrical Inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: >Electrical components concealed behind finished surfaces are not inspected. >Only a representative sampling of outlets and light fixtures were tested. >Furniture and/or storage may restrict access to some electrical components which may not be inspected. >The inspection does not include remote control devices, alarm systems and components, low voltage wiring, systems, and components, ancillary wiring, systems, and other components which are not part of the primary electrical power distribution system. SMOKE DETECTORS > If no smoke detectors are presently installed in the building, it is recommended that smoke detectors be installed at least in the ceiling of the basement near the mechanical equipment, as well as in the hall way ceiling outside sleeping rooms. >Carbon Monoxide Detectors are now required by some jurisdictions when the house contains any

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 9 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 11: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Electrical (Continued)gas-burning appliances or has an attached garage. These devises should be placed and maintained in accordance with the manufacturers directions. Smoke detectors installed in the house should be checked every 2 - 3 weeks to insure that they function.

Service Size Amps: 200 Volts: 110-240 VAC Acceptable Service: Aluminum Acceptable 120 VAC Branch Circuits: Copper Acceptable 240 VAC Branch Circuits: Copper Acceptable Aluminum Wiring: Acceptable Conductor Type: Armored cable, Non-metallic sheathed cable Acceptable Ground: Plumbing ground only Marginal Smoke Detectors: Battery operated Basement Electric Panel Defective Manufacturer: Square D Panel is rusted inside, Recommend existing panel be replaced Maximum Capacity: 200 Amps

Acceptable Main Breaker Size: 200 Amps Defective Breakers: Copper Corrosion on breakers,

Corrosion on breakers from water penetration-require replacement of affected breakers

Acceptable GFCI: At GFCI receptacles only Is the panel bonded? Yes

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 10 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 12: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

StructureLimitations of Structural Inspection This is a visual inspection limited in scope by (but not restricted to) the following conditions: >Structural components concealed behind finished surfaces could not be inspected. >Only a representative sampling of visible structural components were inspected. >Furniture and/or may restrict access to some structural components. >Engineering or architectural services such as calculation of structural capacities, adequacy, or integrity are not part of a home inspection

Acceptable Structure Type: Wood frame Defective Foundation: Block Mortar has failed needs

repointing., Parge coating coming off on exterior

Acceptable Differential Movement: Acceptable Beams: Acceptable Bearing Walls: Acceptable Joists/Trusses: Acceptable Piers/Posts: Acceptable Floor/Slab: Defective Stairs/Handrails: Wood stairs with wood handrails Handrails missing (Safety), Stair height varies

(safety)., Open risers (safety) Defective Subfloor: Dimensional wood Moisture damage

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 11 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 13: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Structure (Continued)Subfloor: (continued)

AtticLimitations of Insulation / Ventilation Inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: >Insulation/ventilation type and levels in concealed areas are not inspected. Insulation and vapor barriers are not disturbed and no destructive tests (such as cutting openings in walls to look for insulation) are performed. >Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection. >An analysis of indoor air quality is not part of our inspection unless explicitly contracted-for and discussed in this or a separate report. >Any estimates of insulation R values or depths are rough average values.

Entire Attic Method of Inspection: In the attic

Marginal Unable to Inspect: 50% Safety and footing

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 12 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 14: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Attic (Continued)Defective Roof Framing: 2x8 Have a qualified contractor

estimate repairs.

Acceptable Sheathing: Dimensional wood, Plywood Marginal Ventilation: Gable and soffit vents Insufficient ventilation for size of structure, Vents covered or

blocked, Recommend additional ventilation be installed Defective Insulation: Fiberglass, Batts Insufficient

insulation present, A qualified contractor is recommended to evaluate and estimate repairs, Insulation batts have fallen out of position-properly reinstall

Marginal Insulation Depth: 6" A qualified contractor is recommended to evaluate and estimate repairs, No insulation present

Not Present Attic Fan: Marginal Wiring/Lighting: 110 VAC lighting circuit Non permanent lighting. Acceptable Moisture Penetration: Previous water penetration noted Marginal Bathroom Fan Venting: Electric fan Bathroom vent blocks gable vent.

BasementLimitations of Interior inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions >Furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block defects. >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

Main Basement Acceptable Unable to Inspect: 30% Storage boxes, Storage shelves Acceptable Ceiling: Exposed framing Acceptable Walls: Masonary block Acceptable Floor: Poured

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 13 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 15: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Basement (Continued)Not Present Floor Drain: Defective Doors: Hollow wood, Solid wood The door has moisture damage, Door opens over stairs.(safety) Marginal Windows: Vinyl hopper, steel hopper No caulking. Marginal Electrical: 110 VAC outlets and lighting circuits Gfci used to power sump pump, Open junction box,

Open wiring. Enclose in junction box.

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 14 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 16: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Basement (Continued)Electrical: (continued)

Acceptable Smoke Detector: Battery operated Not Present HVAC Source: Acceptable Vapor Barrier: Acceptable Insulation: Fiberglass Acceptable Ventilation: Windows Marginal Sump Pump: Pedestal, Submerged Sump pump not connected to dedicated circuit, Extension cords

present, Sump crock was completely dry/empty-unable to test pump operation/piping for leaks

Acceptable Moisture Location:

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 15 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 17: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Basement (Continued)Defective Basement Stairs/Railings: Wood stairs with wood handrails Improper riser height, Missing railing

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 16 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 18: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Basement (Continued)Basement Stairs/Railings: (continued)

Air ConditioningLimitations of Air Conditioning Inspection: If the outside temperature has not been at least 65 degrees F. for the past 24 hours, an air conditioning system can not be checked with out possibly damaging the compressor. In this situation, it is suggested that the present owner of the property warrant the operational status on the unit on a one-time start-up and cool-down basis when warmer weather allows.

Side yard AC System Not Inspected A/C System Operation: Not inspected The unit is currently in service beyond the manufactures

stated design life, Unable to test. Temp below 65F Not Inspected Condensate Removal: Plastic tubing Marginal Exterior Unit: Pad mounted Manufacturer: Ruud Model Number: UAJC 030 JAS Serial Number: 4812-M1892 2376 Area Served: 1st floor Approximate Age: 20 yrs old Fuel Type: 220 VAC Temperature Differential: Type: Central A/C Capacity: Not listed Not Inspected Visible Coil: Acceptable Refrigerant Lines: Low pressure and high pressure Acceptable Electrical Disconnect: Breaker disconnect Acceptable Exposed Ductwork: Insulated flex Not Inspected Blower Fan/Filters: Not Inspected Thermostats:

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 17 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 19: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Heating SystemLimitations of Heating Inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: >The adequacy of heat supply or distribution balance is not inspected. >The interior of flues or chimneys which are not readily accessible are not inspected. >The furnace heat exchanger, humidifier, or dehumidifier, and electronic air filters are not inspected. >Solar space heating equipment/systems are not inspected.

Basement Heating System Acceptable Heating System Operation: Adequate Suspected asbestos present, Service recommended Manufacturer: Peerless

Model Number: WBV 03 110 SP Serial Number: 530223-200510 Type: Boiler system Capacity: 91,000 BTUHR Area Served: 1st floor Approximate Age: 30 yrs plus Fuel Type: Oil Acceptable Heat Exchanger: Unable to Inspect: 90% Acceptable Blower Fan/Filter: Acceptable Distribution: Acceptable Circulator: Acceptable Draft Control: Acceptable Flue Pipe: Acceptable Controls: Acceptable Devices: TPRV drain tube. Drain tube missing.(safety) Acceptable Thermostats: Programmable Acceptable Fuel Tank: Oil tank

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 18 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 20: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Heating System (Continued)Tank Location: Basement Suspected Asbestos: Yes

PlumbingLimitations of Insulation / Ventilation Inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions: >Insulation/ventilation type and levels in concealed areas are not inspected. Insulation and vapor barriers are not disturbed and no destructive tests (such as cutting openings in walls to look for insulation) are performed. >Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection. >An analysis of indoor air quality is not part of our inspection unless explicitly contracted-for and discussed in this or a separate report. >Any estimates of insulation R values or depths are rough average values.

Acceptable Service Line: Copper Acceptable Water Lines: Copper Acceptable Drain Pipes: PVC Acceptable Service Caps: Accessible Acceptable Vent Pipes: PVC Basement Water Heater Acceptable Water Heater Operation: Functional at time of inspection Manufacturer: Kenmore Model Number: 153 32 6463 Serial Number: LO7A 05 9618 Type: Electric Capacity: 40 Gal. Approximate Age: New Area Served: Whole building Defective TPRV and Drain Tube: Missing drain tube

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 19 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 21: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Bathroom Main Bathroom Not Present Closet: Acceptable Ceiling: Paint Acceptable Walls: Paint and tile Acceptable Floor: Tile Acceptable Doors: Hollow wood Acceptable Windows: Vinyl double hung Marginal Electrical: 110 VAC Non-GFCI circuit Acceptable Counter/Cabinet: Acceptable Sink/Basin: Granite/Porcelain Marginal Faucets/Traps: Tub drain stopper not working Acceptable Tub/Surround: Fiberglass tub and ceramic tile surround Marginal Shower/Surround: Fiberglass pan and ceramic

tile surround Glass door does not close properly.

Acceptable Spa Tub/Surround: Fiberglass tub and ceramic tile surround Acceptable Toilets: American Standard Acceptable HVAC Source: Air exchange ventilation Acceptable Ventilation: Electric ventilation fan and window

KitchenLimitations of Interior inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions >Furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block defects. >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

1st Floor Kitchen Acceptable Cooking Appliances: Acceptable Ventilator: Not Inspected Dishwasher: Air Gap Present? Yes Acceptable Refrigerator: Not Present Microwave: Acceptable Sink: Stainless Steel

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 20 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 22: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Kitchen (Continued)Marginal Electrical: 110 VAC GFCI Open grounds noted at

3 prong outlets

Acceptable Plumbing/Fixtures: Chrome Acceptable Counter Tops: Acceptable Cabinets: Wood Acceptable Ceiling: Paint Acceptable Walls: Paint Marginal Floor: Tile Missing tile. Acceptable Windows: Vinyl double hung Acceptable HVAC Source: Air exchange ventilation

Bedroom Master Bedroom Acceptable Closet: Single Acceptable Ceiling: Paint Acceptable Walls: Paint Acceptable Floor: Carpet Acceptable Doors: Hollow wood Acceptable Windows: Vinyl double hung Acceptable Electrical: 110 VAC outlets and lighting circuits Acceptable HVAC Source: Steam radiator. Not Present Smoke Detector: Front Bedroom Acceptable Closet: Two Marginal Ceiling: Texture paint Evidence of past or

present water staining

Acceptable Walls: Paint Acceptable Floor: Hardwood

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 21 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 23: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Bedroom (Continued)Acceptable Doors: Hollow wood Acceptable Windows: Vinyl double hung Acceptable Electrical: 110 VAC outlets and lighting circuits Acceptable HVAC Source: Steam radiator. Not Inspected Smoke Detector:

Living SpaceLimitations of Interior inspection As we have discussed and as described in your inspection contract, this is a visual inspection limited in scope by (but not restricted to) the following conditions >Furniture, storage, appliances and/or wall hangings are not moved to permit inspection and may block defects. >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments are not inspected.

Dining Room Living Space Acceptable Ceiling: Paint Acceptable Walls: Paint and paneling Acceptable Floor: Hardwood Acceptable Windows: Wood double hung Acceptable Electrical: 110 VAC outlets and lighting circuits Acceptable HVAC Source: Steam radiator. Acceptable Smoke Detector: Living Room Living Space Acceptable Ceiling: Paint Acceptable Walls: Paint Acceptable Floor: Hardwood Acceptable Windows: Vinyl double hung Acceptable Electrical: 110 VAC outlets and lighting circuits Acceptable HVAC Source: Steam radiator. Not Present Smoke Detector:

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 22 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 24: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Laundry Room/AreaLimitations of Laundry Room/ Area Inspections Clothes washers and dryers can not be inspected properly with out a load of laundry, so these appliances are not tested other then to determine weather they are operating. A washer/ dryer has an average life of 6 - 12 years. When hooking up a dryer, it must be kept vented to the exterior to prevent excessive moisture from building up in the house. Washers and dryers often not included in a sales contract, or are included in "as is" condition.

Basement Laundry Room/Area Acceptable Ceiling: Exposed framing Acceptable Walls: Masonary block Acceptable Floor: Poured

Acceptable Electrical: 110 VAC/220 VAC Acceptable Smoke Detector: Battery operated Not Present HVAC Source: Not Present Laundry Tub: Not Present Laundry Tub Drain: Acceptable Washer Hose Bib: Gate valves Acceptable Washer and Dryer Electrical: 110-240 VAC Marginal Dryer Vent: Metal flex Needs cleaning Acceptable Washer Drain: Wall mounted drain

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 23 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 25: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Marginal SummaryThis summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report.

Lots and Grounds 1. Steps/Stoops: Concrete Spalling cement on cheeks of platform. 2. Deck: Treated wood No framing hangers used, Not lag bolted to house 3. Vegetation: Trees Tree limbs over hang the roof and should be cut back 4. Window Wells: Drain not present No covers 5. Fences: Wood, Chain link Needs replacement

Exterior 6. Entire Exterior Surface Type: Vinyl siding

Roof 7. Entire Roof Surface Material: Asphalt shingle 8. Skylights: Plastic Not suitable for low slope application. 9. Chimney Flue/Flue Cap: Clay

Garage/Carport 10. Attached Garage Door Opener: Overhead Door No safety reverse system in operation 11. Attached Garage Floor/Foundation: Concrete block Foundation spalling.

Electrical 12. Smoke Detectors: Battery operated

Attic 13. Entire Attic Unable to Inspect: 50% Safety and footing 14. Entire Attic Ventilation: Gable and soffit vents Insufficient ventilation for size of structure, Vents covered or

blocked, Recommend additional ventilation be installed 15. Entire Attic Insulation Depth: 6" A qualified contractor is recommended to evaluate and estimate repairs, No

insulation present 16. Entire Attic Wiring/Lighting: 110 VAC lighting circuit Non permanent lighting. 17. Entire Attic Bathroom Fan Venting: Electric fan Bathroom vent blocks gable vent.

Basement 18. Main Basement Windows: Vinyl hopper, steel hopper No caulking. 19. Main Basement Electrical: 110 VAC outlets and lighting circuits Gfci used to power sump pump, Open junction

box, Open wiring. Enclose in junction box. 20. Main Basement Sump Pump: Pedestal, Submerged Sump pump not connected to dedicated circuit, Extension

cords present, Sump crock was completely dry/empty-unable to test pump operation/piping for leaks Air Conditioning

21. Side yard AC System Exterior Unit: Pad mounted Bathroom

22. Main Bathroom Electrical: 110 VAC Non-GFCI circuit 23. Main Bathroom Faucets/Traps: Tub drain stopper not working 24. Main Bathroom Shower/Surround: Fiberglass pan and ceramic tile surround Glass door does not close

properly.

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 24 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 26: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Marginal Summary (Continued)Kitchen

25. 1st Floor Kitchen Electrical: 110 VAC GFCI Open grounds noted at 3 prong outlets 26. 1st Floor Kitchen Floor: Tile Missing tile.

Bedroom 27. Front Bedroom Ceiling: Texture paint Evidence of past or present water staining

Laundry Room/Area 28. Basement Laundry Room/Area Dryer Vent: Metal flex Needs cleaning

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 25 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.

Page 27: Home Inspection · 2020-04-25 · >Carpeting, window treatments, central vacuum systems, household appliances, recreational facilities, paint, wallpaper, and other finish treatments

Defective SummaryThis summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report.

Lots and Grounds 1. Porch: Wood Cement raised patio under deck is failing., A qualified contractor is recommended to evaluate and

estimate repairs 2. Basement Stairwell: Concrete Stairs unsound or unsafe, A qualified contractor is recommended to evaluate and

estimate repairs Roof

3. Chimney Chimney: Terra cotta Flue liner used as chimney. Chimney covered with tar,unable to inspect masonary., A qualified contractor is recommended to evaluate and estimate repairs

4. Chimney Chimney Flashing: Tar covered Improper installation- counter flashing is not recessed into mortar joints- requires corrections

Electrical 5. Basement Electric Panel Manufacturer: Square D Panel is rusted inside, Recommend existing panel be replaced 6. Basement Electric Panel Breakers: Copper Corrosion on breakers, Corrosion on breakers from water

penetration-require replacement of affected breakers Structure

7. Foundation: Block Mortar has failed needs repointing., Parge coating coming off on exterior 8. Stairs/Handrails: Wood stairs with wood handrails Handrails missing (Safety), Stair height varies (safety)., Open

risers (safety) 9. Subfloor: Dimensional wood Moisture damage

Attic 10. Entire Attic Roof Framing: 2x8 Have a qualified contractor estimate repairs. 11. Entire Attic Insulation: Fiberglass, Batts Insufficient insulation present, A qualified contractor is recommended

to evaluate and estimate repairs, Insulation batts have fallen out of position-properly reinstall Basement

12. Main Basement Doors: Hollow wood, Solid wood The door has moisture damage, Door opens over stairs.(safety)

13. Main Basement Basement Stairs/Railings: Wood stairs with wood handrails Improper riser height, Missing railing

Plumbing 14. Basement Water Heater TPRV and Drain Tube: Missing drain tube

Caveat Emptor Home Inspectors11:21 January 07, 2013 Page 26 of 26

demoforsite.inspx

Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.