Upload
serbanel
View
54
Download
9
Tags:
Embed Size (px)
DESCRIPTION
energy
Citation preview
Power Transmission & Distribution
en.chintelectric.com
T D&
High Voltage Capacitor
High Voltage Capacitor
2012/2013
Brief IntroductionAbout CHINT T&D
New Orders
Employee
CHINT T&D is a branch company of CHINT Group Corporation. 2 Covering 900,000m , with an investment of 450 million USD.
CHINT T&D has one of the world largest power transmission & distribution equipment manufacturing centers in Shanghai.
Around 660 million USD in the year of 2011
4,300 employees
About CHINT Group
Product RangePower Transformer up to 750kVDistribution Transformer up to 35kVDry-type Transformer up to 35kVReactor up to 220kVGIS up to 252kVHV Circuit Breaker & Disconnector up to 252kVVCB 12~40.5kVMV & LV Switchgear Panel, Prifabricated Substation up to 40.5kVLV Terminal Box, Bus Bar Duct Surge Arrester & Insulator up to 500kV, CT & PT up to 220kVPower Distribution Automation SystemCable up to 36kVCapacitorTurn-key Solution
CHINT is the leading player in the Power Transmission & Distribution industry and Low-voltage electrics industry in China. Founded in 1984 by a few local entrepreneurs and currently hiring 18,000 employees worldwide.Ranked in The 2011 BCG 100 New Global Challengers (The Boston Consulting Group, 2011) CHINT Low-voltage Electrics launched IPO at the Shanghai Stock Exchange of China (2010)No.2 in China Electricity Industry's Top 10 Most Competitive Enterprises (China Machinery Industry Information Institute, 2009) No.3 in China Electricity Industry(China Machinery Industry Information Institute, 2009)No.240 in Top 500 Chinese-Companies (China Enterprise Federation, 2009).No.1 in Power T&D and the controlling devices (China Machinery Summit, 2009)Ranked in Top 100 Best Employers in China (China Entrepreneurs Summit, 2008)No.15 in Top 100 Private & Public Companies in China (Forbes, 2006)National Quality Management Award(2004) (One of top honours for manufacturing companies in China)Worldwide business operation with 2,000 sales offices, agents, distributors, and local partners in domestic Chinese market and distributors & local partners in over 105 countries. International branches or regional offices set up in USA, UAE, Germany, Russia, Brazil, Ukraine, Hong Kong of China, UK and Nigeria. CHINT stretches its business to a new frontier of solar energy by setting up a branch company specialized in the solar energy products development. The R&D center of CHINT is recognized as the National Level R&D Center run by the companies, which means the R&D level of CHINT Group has reached the leading position in the industry of China.
Sales ReferencesWith a worldwide presence in over 117 countries such as, Italy, Germany, Estonia, USA, Russia, Japan, Australia, Saudi Arabia, Poland, Ukraine, Mongolia, Kazakhstan, Pakistan, Myanmar, Indonesia, Thailand, Egypt, Yemen, Algeria, Morocco, Congo, Tanzania, Mali, Kenya, South Africa, Ghana, Nigeria, Colombia, etc, CHINT T&D provides reliable and high-qualified products and solutions to clients engaged in different businesses.
Industrial End UserBHP Billiton-AustraliaFincantieri-ItalyChevron-USAAGGREKO-UKTATA Chemical-India INVISTA-USA JFE Steel-Japan VISY Paper-Australia Sasol-South AfricaSHANGRI-LA Hotel-Phillippine De Beers-Botswana/South Africa CODELCO-Chile Barrick Gold-South Africa UML Steel-India Serebryabskiy Cement Plant-Russia Alake Aluminum Factory-Iran SIBAYAK geothermal Power Plant-Indonesia Industrial Training Center-MyanmarKingdom Iron and Steel co.-Saudi ArabiaSMCO-D.R. Congo
Engineering & ContractingEIFFAGE-France HATCH-Canada FAST JV-AustraliaDowner EDI-Australia Genser Power-Ghana
EPCNational Electricity Company-PakistanSaint Gobain-FrancePEC-YemenNEA-NepalSMCO-D.R. CongoTANESCO-TanzaniaMore >>>
ENEL-ItalyCELEC S.A-EcuadorCNEL-EcuadorICE-Costa RicaENDESA-ChileEnersis-ChileUNE-CubaFingrid-FinlandEAC-CyprusHS ORKA HF-IcelandENE-AngolaENA-ArmeniaEesti.Energia-EstoniaEVN-VietnamNEA-NepalTANESCO-TanzaniaRECO-RwandaSNEL-D.R. CongoMEPE-MyanmarKPLC-KenyaKENGEN-KenyaZESCO-ZambiaVRA-GhanaSONABEL-Burkina FasoSBEE-BeninREGIDESO-BurundiPEDEEE-SyriaTEIAS-TurkeyPEEGT-SyriaPEC-YemenQESCO-PakistanNEC-SudanPHCN-NigeriaTATA Power-IndiaWARD-Lebanon NEPCO-Jordan
Utility User
Contents
1
15
25
28
33
39
37
TBB type high-voltage shunt capacitor complete equipments
TBBF(X) type high-voltage shunt capacitor complete equipments
TBBS substation type auto-switched high-voltage shunt capacitor equipment
TBBX type high-voltage reactive on the spot compensating equipments
TBBZ pole-mounted Auto-switch High-voltage Shunt-capacitor Installation
TAL type alternating filter capacitor complete equipments
B M all film high voltage shunt capacitorFA
TBB type compensate installation of high voltage shunt capacitor
4. Type meaning and specification
1. General Description
3. Application Ambient Conditions
Rated voltage of installation
The patience voltage (RMS value) with power frequency
for 1min in primary circuit
Impulsion withstand voltage (RMS value)in primary circuit (1.25)/50s peak value
The patience voltage (RMS value) with power frequency
for 1min in secondary circuit61035
324295
6075200
222
Power frequency over-voltage The longest persist time Explain1.101.151.201.30
Long time30 min each 24 h5min1min
The most value of over-voltage isn't exceed 1.1 Un for long time.Adjust and fluctuate of system voltage.As light load, the voltage raise.As light load, the voltage raise.
Table 2
GB50227-2008
JB/T7111-1993
JB/T10577-2006
DL/T604-2009
2. Executing Standards
High-voltage shunt capacitor installations are applicable to 6-35KV electric power system to increase
the power factor, reduce circuit losses and improve voltage quality.
T BB
Connection: A-single star B-double star
Capacitance of per capacitor (kvar)
Rated capacitance (kvar)
Rated voltage (kV)
Parallel compensate
Installation
3.1 Indoor: Cabinet type, outdoor: frame type.3.2 Altitude1000m,consult us if the altitude1000m.3.3 Operating temperature: Indoor equipment: -25+45, Outdoor equipment: -40+45.3.4 No causticity gas,vapor, no inflammable gas, no blaze, no explosion risk, no frequent violent shake;
5.1 Insulate level Unit: kV Table 1
5.2 Steady state over-voltage
6. The primary connecting line of compensate installation6.1 Connecting line fashion of compensate installation: there are "Y" and "YY" connecting line fashion. The neutral point don't connected to earth. The primary connecting line drawing and primary system connecting line principle drawing for every product to see drawing 12.6.2 The configuration and setting of the compensate installation of shunt capacitor. 6.2.1 Configuration of cabinet.
5. Main Technical Parameter
P1.
High Voltage Capacitor
The technology parameter of compensate installation of shunt capacitor.
No. Type specRated parameter
Shunt capacitorOutline dimension
(LWH)Drawing
No.Ue(kV) Ie(A) Qe(kvar)123456
TBB10-800/134-AKTBB10-900/150-AKTBB10-1000/167-AKTBB10-1200/200-AKTBB10-1500/250-AKTBB10-1600/267-AK
11/311/311/311/311/311/3
4247.2526378.784
8009001000120015001600
BFM11/ -134-1BFM11/3-150-1BFM11/3-167-1BFM11/3-200-1BFM11/3-250-1BFM11/3-267-1
3
2200 1350 2600 3
4
kV
COSVARhkA Wh Wh VARh COS?kA kV kVkV
YY Y
Y
kV
L
TVTV
LQSE QSE
10kV10kV
35kV35kV Primary system connecting line drawing of the compensate installation
The connecting line fashion of reactor is placed on neutral point side
Drawing 1
Drawing 2
Primary system connecting line drawing of the compensate installation
YYY
Y
kV kVkVkA COS?VARhWhWhkA VARh COS?
kV
kVkVkV
kV
10kV 10kV
35kV 35kV
The connecting line fashion of reactor is placed on supply side
QSE
L TV TV L
QSE
P2.
High Voltage Capacitor
6.2.1.1 Outline drawing of the reactor is placed on neutral point side.
Drawing 3 outline of the compensate installation of shunt capacitor.
TBB - / -
kvar
KV
JB/T7111-1993
50 Hz
A
%
KV
TBB10TBB10
L
H
L1
O
I I
O
6.2.1.2 Inside configuration of the reactor is placed on neutral point side.
Drawing 4 Inside configuration drawing of the compensate installation of shunt capacitor.
CCB
B A A
H
LL1
P3.
High Voltage Capacitor
6.2.2 Another type of series reactor is placed on neutral point side.
The technology parameter of compensate installation of shunt capacitor.
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Drawing
No.Ue(kV) Ie(A) Qe(kvar)1234567
2TBB10-1200/200-AK2TBB10-1404/234-AK2TBB10-1500/250-AK2TBB10-1602/267-AK2TBB10-1800/300-AK2TBB10-2004/334-AK2TBB10-2400/400-AK
11/311/311/311/311/311/311/3
6373.678.48494.4105126
1200140415001602180020042400
BFM11/ -200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-267-1BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1
3
7600 1400 2600 5
6
Table 2
6.2.2.1 Outline of series reactor is placed on neutral point side.
Drawing 5 Outline and fixing dimension of the compensate installation of shunt capacitor.
L2L2L1LL
L1L2L2
H
6.2.2.2 Inside configuration drawing of series reactor is placed on neutral point side.
Drawing 6 Inside configuration of the compensate installation of shunt capacitor.
H
L2 L2 L1L L
L1 L2 L2
P4.
High Voltage Capacitor
6.3 Hollow reactor is placed on supply side.
The technology parameter of compensate installation of shunt capacitor. Table 3
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Drawing
No.Ue(kV) Ie(A) Qe(kvar)12345678
TBB10-4008/167-AKTBB10-4800/200-AKTBB10-5616/234-AKTBB10-6000/250-AKTBB10-6408/267-AKTBB10-7200/300-AKTBB10-8016/334-AKTBB10-9600/400-AK
11/11/311/311/311/311/311/311/3
3 210252295315336378420504
40084800561660006408720080169600
BFM11/ -167-1BFM11/3-200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-267-1BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1
3
5800 1600 2600 7
8
6.3.1 Outline and fixing of the compensate installation of shunt capacitor (using dry type hollow reactor).Drawing 7 Outline of the compensate installation of shunt capacitor (reactor is placed on supply side).
RD GN YE HAU
KV
TBB TBB TBBTBBTBB
H
LL2L2L2L1
6.3.2 Inside configuration drawing of series reactor is placed on supply side.
Drawing 8 Inside configuration of the compensate installation of shunt capacitor (reactor is placed on supply side).
L1 L2 L2 L2L
H
P5.
High Voltage Capacitor
6.4 Another type of series reactor is placed on supply side.
The technology parameter of compensate installation of shunt capacitor. Table 4
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Drawing
No.Ue(kV) Ie(A) Qe(kvar)123456
TBB10-2400/100-AKTBB10-3000/125-AKTBB10-3216/134-AKTBB10-3600/150-AKTBB10-4008/167-AKTBB10-4800/200-AK
11/11/311/311/311/311/3
3 126157.4168.8188.9210.3252
240030003216360040084800
BFM11/ -100-1BFM11/3-125-1BFM11/3-134-1BFM11/3-150-1BFM11/3-167-1BFM11/3-200-1
3
5200 1200 2600 9
10
6.4.1 Another type of series reactor is placed on front side.Drawing 9 Outline and fixing dimension of the compensate installation of shunt capacitor (reactor is placed on supply side).
TBB10 TBB10 TBB10 TBB10 TBB10
KV
L2L2L1
H
L2L
O
I I
O O
I I
O O
I
6.4.2 Another inside configuration of series reactor is placed on supply side.
Drawing 10 Inside configuration drawing of the compensate installation of shunt capacitor (reactor is placed on supply side).
L2L2
H
LL2L1
P6.
High Voltage Capacitor
6.5 The frame type of compensate installation of shunt capacitor.
6.5.1 The technology parameter of installation
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Drawing
No.Ue(kV) Ie(A) Qe(kvar)12345678910111213141516171819202122232425262728
TBB10-2400/200-AKWTBB10-3000/200-AKWTBB10-4500/300-AKWTBB10-4800/400-AKWTBB10-6000/400-AKWTBB10-7500/500-AKWTBB10-9000/334-AKWTBB10-21600/450-BLWTBB10-2000+2000-AKWTBB10-3000+3000-AKWTBB10-3600+3600-AKWTBB10-4800+4800-AKWTBB10-2100+4200-AKWTBB10-2400+4800-AKWTBB10-4800+9600-AKWTBB35-4000/334-ACWTBB35-6000/500-ACWTBB35-8000/334-ACWTBB35-9000/500-ACWTBB35-9600/400-ACWTBB35-12000/500-ACWTBB66-10020/167AQWTBB66-15000/250-AQWTBB66-18000/300-AQWTBB66-20040/334-AQWTBB66-36000/500-AQWTBB110-12000/167-AQWTBB110-28000/195-AQW
11/11/311/311/311/311/311/311/311/311/311/311/311/311/311/31121121121121121122022022022022025.9125.912
3 1261572362523153934721134105+105157+157189+189252+252110+220126+252252+504609112013614518183.512515016730056132
24003000450048006000750090002160040006000720096006300720014400400060008000900096001200010020150001800020040360001200028000
BFM11/3-200-1WBFM11/3-200-1WBFM11/3-300-1WBFM11/3-400-1WBFM11/3-400-1WBFM11/3-500-1WBFM11/3-334-1WBFM11/3-450-1WBFM11/3-334-1WBFM11/3-334-1WBFM11/3-300-1WBFM11/3-400-1WBFM11/3-350-1WBFM11/3-400-1WBFM11/3-400-1WBFM11-334-1WBFM11-500-1WBFM11-334-1WBFM11-500-1WBFM11-400-1WBFM11-500-1WBFM20-167-1WBFM20-250-1WBFM20-300-1WBFM20-334-1WBFM20-500-1WBFM5.9-167-1WBFM5.9-195-1W
540030003920620030003920620030003920540030003920620030003920680036003920700036003920760070003300660048004300760048004300780048004300780048004300780048004300800050004300900060004300600070003700660072003700600070003700660072003700900073003700600072003700800080004000800080004000800080004000800080004000100001000040002100013000600021000180006000
11
12
13
14
15
16
17
Table 5
P7.
High Voltage Capacitor
6.5.2 Outline configuration of the installation
Drawing 11
Primary principle drawing of the installation
QSE L
TV
CFUFV10kV
W
B
CCC C
CB
CC
BB
CC
B
L
H
P8.
High Voltage Capacitor
Drawing 12
Primary principle drawing of the installation
TAQSE L
CFV
10kV
H
L
C
B
A
W
P9.
High Voltage Capacitor
Drawing 13
L
TV
C
FU
FV
Primary connecting line principle drawing of the installation
10kV
FV
FU
C
TV
L
QSE
QG
QSE
C1
C2C2
C1 C1
C2 B2
B1
B2
B1C1
C2
L
H
W
P10.
High Voltage Capacitor
Drawing 14
QSE
L
TV
C
FU
FV
Primary connecting line principle drawing of the installation
10kV
FV
FU
C
TV
L
QSE
QG
C2 C2 C2C2C2
C1C1C1
C2
C1 B1 B1
B2B2
B2
L
H
W
P11.
High Voltage Capacitor
Drawing 15
35kV
FV
C
TV
L
QSE
CTo frame
Primary principle drawing of the installation
A
X
A
A1
B1
B
Y
Z
C
C1
B
C C
C
C
WL
H
P12.
High Voltage Capacitor
Drawing 16
TA
FUC
CFUFU
C
Primary principle drawing of the installation
CFU
L
66kV
FV
QSE
C
B
A
H
W
L
P13.
High Voltage Capacitor
7. The notice of user subscribe for goods7.1 The subscribe for goods by user want to write about type, spec, quantity and high order harmonic condition in network,and configure demand for discharge wingding,series reactor and shunt capacitor.7.2 User must provide fashion of primary connecting line and secondary protecting, and room plane disposal and dissect drawing(Up enter line or below enter line;left or right enter line;use cable or busbar).7.3 The short circuit discharge capability Sd of compensate installation.7.4 The altitude, temperature and air condition.7.5 The time of deliver for goods and fashion of transport.7.6 If there is special demand, deliver a letter to consult, please.
Drawing 17
TA
CTA110kV FV LQSE QF C
To frame
Primary principle drawing of the installation
QSE
L
H
A
CC
BB
AA
W
P14.
High Voltage Capacitor
( )TBBF X type High-voltage Shunt Capacitor Installation1. General DescriptionTBBF type high-voltage shunt capacitor installations are usually produced in forms of cabinet or frame. The equipments use vacuum contactor or vacuum breaker & reactive voltage auto-control equipment to control the capacitor bank, in this way, the capacitor bank will be auto-switched. The equipments are produced in purpose of increasing the power factor, reducing circuit losses and improving voltage quality.According to the reactive gross which should be compensated, the equipment could be used as one whole group or some certain number of groups, with reasonable control & protect way, can easily realize auto-switched of the capacitor bank.
2. Executing Standards GB50227-2008 JB/T7111-1993 JB/T10577-2006 DL/T604-2009
3. Application Ambient Conditions
T BB F K: open delta protection L: unbalance current protection Connection: A-single star B-double star Capacitance of per capacitor (kvar) Rated capacitance (kvar) Rated voltage (kV) Auto-switched in groups Parallel compensate Installation
3.1 Indoor: Cabinet type, outdoor: frame type.3.2 Altitude1000m,consult us if the altitude1000m.3.3 Operating temperature: -25+45.3.4 Relative humidity: daily mean95%, monthly mean90%.3.5 No causticity gasvapor, no inflammable gas, no blaze, no explosion risk, no frequent violent shake.
4. Type Meaning and Specification
Based on TBBF, we could make it in a preassemble chamber, which is similar to TBBF, and will excellently be suitable for outdoor use. We call the product TBBFX type.
TBBF
TBBFX
P15.
High Voltage Capacitor
5. Main Technology Parameter5.1 TBBF
Device typeRated voltageRated currentRated capabilityRated frequency4s hot stabilization current(availability value)KA.Act stabilization current(peak value)KA.Type of capacitor unitMedium of capacitor unit
Protect fashionDevice typeConnect line fashion
Insulate level in secondarySurface deal, color protect grand(cabinet type)
Reactance ratio of series reactor percent for collocate whole set.Tolerance of capacitorMost ratio of 3 phasesAllow tolerance of inductanceAverage tolerance of 3 phase inductanceDischarge capability of fuse
TBBF10-/ -AK(W)10kVAkvar50Hz202531.5506380BFM11/3--1(W)
XK= %
TBBF6-/ -AK(W)6 kVAkvar50Hz
BFM6.6/3--1(W)All film medium of M/DBT
XK= %0+5%1.020+5%2%12kJ
TBBF35-/ -AKW35 kVAkvar
BFM11/3--1(W)
XK= %
50Hz
Open delta voltage protect,Neutral imbalance current protect or owe-voltage, owe-current, and over-current protectingCabinet typeSingle or double star typebetween phases32kV,phase to earth32kV(Test value on altitude 1000m)60kV(Test value on altitude 1000m)
Cabinet type Frame type
1 min patience voltage in power frequency (RMS value)
Impact patience voltage to earth
1 min patience voltage in power frequency (RMS value)
Impact patience voltage to earth
between phases42kV,phase to earth42kV between phases95kV,phase to earth95kV
75kV(Test value on altitude 1000m)
200kV(Test value on altitude 1000m)
51kV(Test value on altitude 1000m)75kV(Test value on altitude 1000m)2.0kVSpray lacquer, Chint B or other Spray lacquer, Chint B or other Hot plating or spray lacquer, Chint B IP20
( )Test value on altitude 1000m ( )Test value on altitude 1000m
IP20
2.0kV 2.0kV
Remark: rated insulate level should be corrected according to altitude high.Performance parameter
Insulate
level of
capacitor
Insulate
level of the
installation
P16.
High Voltage Capacitor
Primary connect line fashion of compensate installation: It is as "Y" fashion and neutral point isn't to earth. To see primary connect drawing 1.
Drawing1 The primary system drawing of TBBF compensate installation.
kV kVkV
YY
kV kVkVkA COS?VARhWh
YY
WhkA VARh COS?
kV
QSE
TA
1TV1C
1L
1FU
1F2F
2FU
2L
2C 2TV
TA
3FU
3L
3C 3TV
TA
3F1kM2kM3kM
QSE
1kM 2kM 3kM1F
TA
1FU
1L
1C 1TV
TA
2F
2TV2C
2L
2FU
3F
TA
3TV3C
3L
3FU
35kV
10kV
35kV
Device typeRated voltage
TBBFX10/AK(W)10 kVA50Hzkvar202531.5506380BFM/ --1(W)3
XK= %0+5%1.020+5%2%12kJ
6 kVA50Hzkvar202531.5506380BFM/3--1(W)
TBBFX6/AK(W)
4s hot stabilization current(availability value)KA.Act stabilization current(peak value)KA.
Reactive ratio of series reactor percent for collocate whole set.
Protect fashionDevice typeConnect line fashion
Insulate level of secondary circuitSurface deal, color protect grand(chamber type)
1 min patience voltage in power frequency (RMS value)
Impact patience voltage to earth
1 min patience voltage in power frequency (RMS value)
Impact patience voltage to earth
Tolerance of capacitorMost ratio of 3 phasesAllow tolerance of inductance
Discharge capability of fuse
Medium of capacitor unit All film medium of M/DBT
Open delta voltage protect,Neutral imbalance current protect or low-voltage, low-current, and over-current protectchamber typeSingle or double star typebetween phases 42kV ,phase to earth42kV(Test value on altitude 1000m)75kV(Test value on altitude 1000m)
75kV(Test value on altitude 1000m)2.0kV
IP36 IP36Spray lacquer, Chint B or other Spray lacquer, Chint B or other
2.0kV
51kV(Test value on altitude 1000m)
60kV(Test value on altitude 1000m)
75kV(Test value on altitude 1000m)
51kV(Test value on altitude 1000m)
between phases phase to earth(Test value on altitude 1000m)
32kV , 32kV
chamber typeSingle or double star type
All film medium of M/DBTType of capacitor unit
XK= %0+5%1.020+5%2%12kJ
Rated currentRated capabilityRated frequency
Performance parameter
Insulate level of capacitor
Average tolerance of 3 phase inductance
Insulate level of the installation
5.2 TBBFX
6. Connect line fashion of compensate installation
P17.
High Voltage Capacitor
7.1 TBBF
7.1.1.1. Technology parameter table of compensate installation.
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Ue(kV) Ie(A) Qe(kvar)123456789
TBBF10-2400/200-AKTBBF10-2800/234-AKTBBF10-3000/250-AKTBBF10-3200/267-AKTBBF10-3600/300-AKTBBF10-4000/334-AKTBBF10-4800/400-AKTBBF10-6000/400-AKTBBF10-7200/400-AK
11/11/311/311/311/311/311/311/311/3
3 126147157.5168189210252315378
240028003000320036004000480060007200
BFM11/ -200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-267-1BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1BFM11/3-400-1BFM11/3-400-1
3 4800 1600 2600480016002600480016002600480016002600480016002600480016002600480016002600580016002600680016002600
Table 1
7.1.1.2 RVT outline of control fashion of power factorDrawing2 Outline of compensate installation of shunt capacitor (RVT control fashion)
AA A
TBBF10
AA A
TBBF10TBBF10 TBBF10 TBBF10
KV
AA A
TBBF10
AA AAA A
AA A
LL1
H
L2
7. Outline and fixing dimension
7.1.1.3 Inside configuration drawing of control fashion of RVT power factor.
Drawing3 Inside configuration drawing of compensate installation of shunt capacitor (RVT control fashion)
AA A
TBBF10 TBBF10
AA A
kVAA A
TBBF10 TBBF10
AA A
TBBF10
AA A
TBBF10
AA A
WL
L2
H
L1
P18.
High Voltage Capacitor
7.1.2 WZK- or one of RCBK voltage reactive control fashion
7.1.2.1 Technology parameter of compensate installation
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Ue(kV) Ie(A) Qe(kvar)12345678
TBBF10-2505/167-AKTBBF10-3000/200-AKTBBF10-3510/234-AKTBBF10-3750/250-AKTBBF10-4005/267-AKTBBF10-4500/300-AKTBBF10-5000/334-AKTBBF10-6000/400-AK
11/11/311/311/311/311/311/311/3
3 131.5157.5184.2196.8210.2236.2262.4317.1
25053000351037504005450050006000
BFM11/ -167-1BFM11/3-200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-267-1BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1
3
58001600 2600
Table 2
According to table 2, WZK or RCBK voltage controller is used as protect instrument in enter line cabinet
and has alarm function. GN19-12 insulate switch is placed in the cabinet. Capacitor bank is switch-
on-off with JCZ5-12 or V12 vacuum contactor which can be automatic or manual. The reactor is used
CKSC dry iron core type ,and the protecting of open delta voltage is achieved by FDG2 or FDGQ2.
The installation is also used DWZK controller in center control room which has RS232 or RS485
communication interface and realize distance automatic control.
7.1.2.2 Outline drawing of RCBK control fashion
Drawing 4 Outline and fixing dimension of compensate installation of shunt capacitor by grouping in cabinet type
AA A
TBBF10
SB2SB1
HR HG HAU
SRSR
HAUHGHR
SB1 SB2SB2SB1
HR HG HAU
SRSB2SB1
HR HG HAU
SR
AA AAA AkV
TBBF10 TBBF10 TBBF10 TBBF10
SR
AA A
HAUHGHR
SB1 SB2
TBBF10
AA A
LA
H
800
O
II
OO
II
OO
I I
O
P19.
High Voltage Capacitor
7.1.2.3 Inside configuration drawing in RCBK control fashion.
Drawing 5 Inside configuration drawing of compensate installation of shunt capacitor by grouping in cabinet type
L800 A
H
7.1
7.1.3.1 Outline drawing
.3 The secondary fashion of WZK- type or RCBK voltage-reactive control.
Drawing 6 The combination between fixation group and adjust group
75
HRHGHY
TBB6
kV AA A
HY HG HR
TBB6
64
AA A
SB2SB1
HR HG HAU
SR
TBBF6TBBF6TBBF6TBBF6
3
SR
HAUHGHR
SB1 SB2
AA Akv
kvar
KV
JB/T7111-1993
50 Hz
A
%
TBBF6
SR
HAUHGHR
SB1 SB2
AA AAA A
21
SB2SB1
HR HG HAU
SR
H
LL2 L1 L2
I
OO
II
O
I
O O
I
O
I I
O
7.1.3.2 Inside configuration drawing.
Drawing 7 The configuration of fixation group and adjust group
L2L2 L1
L
H
P20.
High Voltage Capacitor
From drawing 6 and 7 can be known, there are a fixation group and 4 capacitor bank which is switch-
on-off. RCBK voltage controller can protect the 4 bank. the controller can run 2 segment busbar which
there are 8 capacitor bank, and can automatic or manual.
7.1.4 Grouping compensate installation for frame type.
7.1.4.1 Technology parameter of the installation. Table 3
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Ue(kV) Ie(A) Qe(kvar)123456
TBBF35-2400+4800-AKWTBBF35-3600+7200-AKWTBBF35-4000+8000-AKWTBBF35-4800+9600-AKWTBBF35-6000+12000-AKWTBBF35-12000+12000-AK
112112112112112112
109162182218273364
72001080012000144001800024000
BAM11-400-1WBAM11-300-1WBAM11-334-1WBAM11-400-1WBAM11-334-1WBAM11-500-1W
10000 6000 370014000600037001400060003700160008000370021000700037001100090003700
According to table 3,DWZK voltage control cabinet is placed in center control room, which is fixed
RS-232 or RS-285 communication interface to realize distance control. enter line switch is GW4-35
or GW5-35,and capacitor bank is used SF6 breaker, and series reactor is used CKSKL dry hollow
core, and discharge wingding is used FBGEC, to realize difference voltage protecting. The outline
configuration is at drawing 8.
7.1.4.2 Outline configuration of installation.
Drawing 8 The drawing of 35kv cabinet type compensate installation by grouping
C
A
C1
C
Z
Y
B
B1
A1
A
X
B
A
C
B
C1
C
Z
Y
B
B1
A1
A
X
C
C
C
C
C
C
L2L1 L3
WH
L
P21.
High Voltage Capacitor
7.2 TBBFX
7.2.1 Technology parameter of compensate installation Table 1
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Ue(kV) Ie(A) Qe(kvar)12345678
TBBFX10-3000/167-AKTBBFX10-3600/200-AKTBBFX10-4200/234-AKTBBFX10-4500/250-AKTBBFX10-4800/267-AKTBBFX10-5400/300-AKTBBFX10-6000/334-AKTBBFX10-7200/400-AK
11/11/311/311/311/311/311/311/3
3 157.8189.0221.1236.2252.3283.4315.6377.9
30063600421245004806540060127200
BFM11/ -167-1BFM11/3-200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-2671BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1
3
6450 2800 3320
According to table 1,enter line cabinet is used as KY28-12 the middle install type switch cabinet.
Main switch is ZN63-12/630-25 (VS1) type breaker, and controller is RVT type which is placed in the
cabinet. Capacitor bank is used for JCZ5-12 vacuum contactor to see drawing 3 and 4.
7.2.2 Outline drawing of chamber type configuration
H
L W
Drawing 2 Outline of chamber type compensate installation of shunt capacitor
7.2.3 Inside configuration drawing of chamber type installation
One of inside configuration of compensate installation of chamber type shunt capacitor.
KYN-12 High voltage switch cabinet
W
TBBF10 TBBF10 TBBF10
L
H
AA AkVkVkVkV kV kV AA A kV kV kV AA A
Drawing 3
P22.
High Voltage Capacitor
The secondary mode of chamber type compensate installation of shunt capacitor.
TBBF high voltage capacitor bank
W
TBBF10 TBBF10 TBBF10
L
H
Drawing 4
7.2.4 The disposal drawing of cabinet (another mode of chamber type configuration)
7.2.4.1 Technology parameter compensate installation Table 2
No. Type specRated parameter
Shunt capacitorOutline dimension
(LW H)Ue(kV) Ie(A) Qe(kvar)12345678
TBBFX10-1500/167-AKTBBFX10-1800/200-AKTBBFX10-2100/234-AKTBBFX10-2250/250-AKTBBFX10-2400/267-AKTBBFX10-2700/300-AKTBBFX10-3000/334-AKTBBFX10-3600/400-AK
11/11/311/311/311/311/311/311/3
3 78.994.5110.5118.1126.1141.7157.8189.0
15031800210622502403270030063600
BFM11/ -167-1BFM11/3-200-1BFM11/3-234-1BFM11/3-250-1BFM11/3-2671BFM11/3-300-1BFM11/3-334-1BFM11/3-400-1
3
4420 2800 3320
According to table 2,GN19-12 switch is used in enter cabinet, and VQC controller is also placed in
the cabinet. BSF02-12/630-25 magnetism-forever type vacuum breaker is used to switch on-off to
capacitor bank which can automatic or manual. To see drawing 5 and 6.
7.2.4.2 Inside configuration drawing of chamber type
The third mode inside configuration drawing of chamber type compensate installation of shunt capacitor
TBBF enter line and switch cabinet
W
DWZK-
kV
2BDS1BDS
SR
HAUHGHR
A AA
A AA
HR HG HAU
SRSR
HAUHGHR
A AA
H
L
I
O O
I I
O
Drawing 5
P23.
High Voltage Capacitor
The fourth mode inside configuration drawing of chambertype compensate installation of shunt capacitor.
TBBF high voltage capacitor bank
W
4 3 2 1
L
H
Drawing 6
P24.
High Voltage Capacitor
TBBS Substation type Auto-switched High-voltage Shunt Capacitor Installation
TBBS substation type auto-switched high-voltage shunt capacitor installation is usually installed
besides 10kV or 6kV system of the substation. The equipment can effectively increase the power
factor, reduce circuit losses, improve voltage quality and compensate reactive power.
The equipment is divided to several capacitor banks, according to the load of system, with auto-
switching of SF6 switch & controlling of micro-controller, we can realize auto compensating of the
reactive power. Meanwhile, some protection, such as open-delta unbalance voltage, single capacitor
error, short circuit, over current, over voltage, under voltage etc, are set up to make system stable
and reliable.
4. Type meaning and specification
1. General Description
TBB S - / -AKW Single star connection, open delta protection
Outdoor installation
Capacitance of per bank (kvar)
Rated capacitance of installation (kvar)
Rated voltage (kV)
Substation type
Shunt capacitor installation
2. Executing Standards GB50227-2008
JB/T7111-1993
DL/T604-2009
3. Application Ambient Conditions3.1 temperature range:-4045.
3.2 altitude2000m.
3.3 sunlight: extent(max)0.1W/cm2.
3.4 wind speed: 35m/s.
3.5 earthquake: 8 degree.
3.6 No causticity gas, vapor, no inflammable gas, no blaze, no explosion risk, no frequent violent shake.
(Consult us if the environment condition is special.)
5. Main Technical Parameters5.1 rated voltage: 6KV or 10kv;
5.2 rated frequency: 50Hz;
5.3 equipment capacitance (max): 20000kvar;
5.4 single bank capacitance (max): 3000kvar;
5.5 rated reactance ratio: selected from 0.1%~1%, 4.5%~6%, 12%~13%.
P25.
High Voltage Capacitor
6. Primary principle drawing 0 1 2 N
Insulate switch
Arrester
Discharge coil
Load switchCurrent transformer
Capability1
1
31
3
Kvar Kvar
3
13
1
2( )switch inside 2( )switch inside 2( )switch inside
Kvar
3
13
1
Name Enter line 2#capacitor bank1#capacitor bank N#capacitor bank
Main organ
Main circuit draw
ing
Remark: The primary principle drawing is belong to a model of project and manufacturer can change from user demand.
Rated voltage of the installation
The patience voltage in frequency for 1min in
primary circuit (RMS value)
The impact patience voltage[(1.25)/50s peak value)
in primary circuit
The patience voltage in frequency for 1min in
secondary circuit (RMS value)
610
3242
6075
2
5.7 Steady state over-voltage.
5.6 Insulate level
Over-voltage in power frequency Most persist time Explain1.101.151.201.30
Long time30 min each 24 h5min1min
The most value of over-voltage isn't exceed 1.1 Un for long time.
When light load, the voltage raise.
Adjust and fluctuate of system voltage.
According to single unit to deploy
According to grouping capacitance or demand user.Series reactor
Fuse
Shunt capacitor
P26.
High Voltage Capacitor
7. Fixing drawing The envisage drawing of installation
Fixing drawing of enter line
1800w
300
1800
2700
Discharge coil
Reactor
Net gate of enclosure
Support insulator
Insulate switch
Control box
Load switch
Arrester
Capacitor
Fuse
P27.
High Voltage Capacitor
TBBX type High-voltage Local Reactive Compensating Installation
With rated voltage 6~10kV, rated frequency 50Hz, which are widely used in 6~10kV three-phase alternating motor to carry out reactive compensating on the spot. So as to reduce the electric energy loss, increase the quality of network voltage, improve the starting ability of electromotor.The biggest feature of the equipment is that the capacitor bank will put in while the motor start, and resect while stop. It's a new energy saving product with great effect, excel in centralized compensating.
TBBX type high-voltage local reactive compensating installations are cabinet type indoor installed.
4. Type Meaning and Specification
1. General Description
GB 50227-2008
JB/T 10557-2006
DL/T 604-2009
2. Executing Standards
TBBX 3N Common type With control supply time-delay switched-on With reactor With reactor, distant control With load switch Indoor, three-phase Rated capacitance (kvar) Rated voltagekV Shunt capacitor installation
3. Application Ambient Conditions3.1 Altitude1000m.
3.2 Indoor use only.
3.3 Temperature range:-4055.
3.4 No causticity gas, vapor, no inflammable gas, no blaze, no explosion risk, no frequent violent shake.
Do not expose it in powerful electric field & magnetic field;
3.5 Relative humidity: daily mean95%, monthly mean90%;
P28.
High Voltage Capacitor
5. Main Technical Parameters
No.
No.
Type
Type
Rated voltage
(kV)
Rated voltage
(kV)
Rated capability of capacitor bank (kvar)
Rated capability of capacitor bank (kvar)
Rated current of capacitor
bank (A)
Rated current of capacitor
bank (A)
Protect fashion
Protect fashion
Type of shunt capacitor
Type of shunt capacitor
12345678910
The parameter table of 6kV capacitor Table 1
TBBX6-90-3NTBBX6-120-3NTBBX6-150-3NTBBX6-180-3NTBBX6-210-3NTBBX6-240-3NTBBX6-300-3NTBBX6-360-3NTBBX6-450-3NTBBX6-600-3N
6666666666
90120150180210240300360450600
8.2511.013.7516.519.2522.027.532.041.2455.0
The fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitor
The fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitorThe fuse protect of unit capacitor
BFM6.3/ 3-30-1BFM6.3/ 3-40-1BFM6.3/ 3-50-1BFM6.3/ 3-60-1BFM6.3/ 3-70-1BFM6.3/ 3-80-1BFM6.3/ 3-100-1BFM6.3/ 3-120-1BFM6.3/ 3-150-1BFM6.3/ 3-200-1
11121314151617181920
The parameter table of 10kV capacitor Table 2
TBBX10-90-3NTBBX10-120-3NTBBX10-150-3NTBBX10-180-3NTBBX10-210-3NTBBX10-240-3NTBBX10-300-3NTBBX10-360-3NTBBX10-450-3NTBBX10-600-3N
10101010101010101010
90120150180210240300360450600
4.956.68.259.911.5513.216.519.824.7433
BFM10.5/ 3-30-1BFM10.5/ 3-40-1BFM10.5/ 3-50-1BFM10.5/ 3-60-1BFM10.5/ 3-70-1BFM10.5/ 3-80-1BFM10.5/ 3-100-1BFM10.5/ 3-120-1BFM10.5/ 3-150-1BFM10.5/ 3-200-1
6. TBBX outline, primary connect line and fixing dimensionDrawing 1 TBBX(6)10--3N
AAA
TBBX
TBBX - / -3NJ
%
kvar
kv
JB/T7111-1993
50 HzA
R
1000900
2000
O
I
P2
P1
1S2
2S2
1S1
2S1
C
FU
GXN-T
F
TA
(6)10kV
P29.
High Voltage Capacitor
TBBX 10- -500/167-3N(6) TBBX(6)10- -450/150-3NTBBX(6)10- -400/134-3N
BFM/3-100-1BFM / -134-13BFM / -150-13BFM / -167-13
TBBX(6)10--300/100-3NCapacitor collocate
Capacitor collocate
Type
Type
Drawing 2 TBBX(6)10--3N
TBBX(6)10--500/167-AKTBBX(6)10--450/150-AKTBBX(6)10--400/134-AK
BFM/3-100-1BFM/3-134-1BFM/3-150-1BFM/3-167-1
TBBX(6)10--300/100-AK
A A A
kgkV
%
A
50 Hz
JB/T7111-1993
kV
kvar
900800
2300
I
O
Tv GXN-T
TA
FUF
KM
C
(6)10kV
P30.
High Voltage Capacitor
Capacitor collocate
Capacitor collocate
Type
Type
Drawing 3 TBBX(6)10--3N
TBBX(6)10--300/100-3N
BFM/3-167-1BFM/3-150-1BFM/3-134-1BFM/3-100-1
TBBX(6)10--400/134-3N
TBBX(6)10--500/167-3NTBBX(6)10--450/150-3N
L
TA
F
GXN-T
FU
C
(6)10kVAAA
kgkV
%
A
50 Hz
JB/T7111-1993
kV
kvar
12001000
2300
O
I
Drawing 4 TBBX(6)10--3N
TBBX(6)10--300/100-3N
BFM/3-167-1BFM/3-150-1BFM/3-134-1BFM/3-100-1
TBBX(6)10--400/134-3NTBBX(6)10--450/150-3NTBBX(6)10--500/167-AK
QS
KM
C
F
FU
TA
GXN-Q
TBBX - / -3NJ
%
kvar
kv
JB/T7111-1993
50 HzA
R
AAA
TBBX10
1000 1200
2300
O
I
P31.
High Voltage Capacitor
LQF
10(6)
C
FU
TA
GX
N-Q
AAA
TBBX10
1400900
2600
I
O
2S1
1S1
2S2
1S2
P1
P2
Capacitor collocate Type
Drawing 5 TBBX(6)10--3N
TBBX-800/267-3NTBBX-750/250-3NTBBX-700/234-3NTBBX-200/67-3N BFM/3-67-1
BFM/3-234-1BFM/3-250-1BFM/3-267-1
TBBX-900/300-3N BFM/3-300-1
P32.
High Voltage Capacitor
TBBZ pole-mounted Auto-switch High-voltage Shunt-capacitor Installation
TBB Z - A- Default: not placed metal fittings and line "J": Placed metal fittings and line "O": The controller is placed in a control box of load switch "1": The controller is placed in a control box for specialties "1": Cold roll armor plate crust "2": Stainless steel board crust "1": Common type, control time or voltage "2": Common type, control time,voltage power factor and reactive power "3": High grade, wireless control test and adjust for close quarter "4": High grade, with communication interface for long-distance Single star connecting line Rated capacitance(kvar) Default: not placed high voltage shunt capacitor Rated voltage (kV) Up pole type The installation of shunt capacitor
TBBZ type spec ( Table 1)
TBBZ-A-110TBBZ-A-110JTBBZ-A-111TBBZ-A-111JTBBZ-A-120TBBZ-A-120JTBBZ-A-121TBBZ-A-121JTBBZ-A-210TBBZ-A-210JTBBZ-A-211TBBZ-A-211J
Control physics: time,voltage
Time,voltage,power factor, reactive power
Close quarter control ,Remote measureRemote adjust
With communication interface,"4 remote"
Cold roll steel board crust
Stainless steel board crust
The controller is placed inside switch
The controller is placed in special control box
The metal fittings and line are placed for match set
Type spec
1 General DescriptionTBBZ series pole-mounted automatic-switching high-voltage shunt-capacitor on and off device are applicable to 10kV and 6kV distribution lines to increase the power factor, reduce circuit losses and improve voltage quality.The device consists of all-film high-voltage shunt capacitor (have internal fuses and discharge resistances within), outdoor switching capacitor bank on and off specially high voltage SF6 load-switch (install CT within), power transformer PT controlling, outdoor high-voltage current transformer, zinc oxide surge arresters, drop-out fuses, reactive power compensation automatic-controller and so on. Based on circuit requirement and presetting by user, they can carry out auto-switching shunt-capacitors on and off (according to time, voltage, power factor or reactive power) to make power factor achieve prearranged value. At the same time, they have perfect protective functions against short-circuit, over-current, over-voltage, under-voltage, lacking-phase, making capacitors which still accumulate electric charge, and etc. FLW(B) outdoor AC high voltage SF6 load switches have the characteristics of long service time, no bounce at closing and no burn-back at opening. Auto-controllers have excellent ability to anti-interfere. So they can ensure that the device work reliably. The device is simple and compact in structure, convenient to be installed.Executing standards: JB/T7111-1993 , DL/T604-2009, Q/ZT273-2001.
2 Type Meaning and Specification
Table 1
P33.
High Voltage Capacitor
B M6.3/ 3-200-1WZAF
B M6.3/ 3-150-1WZAF
B M6.3/ 3-120-1WZAF
B M6.3/ 3-100-1WZAF
B M6.3-200-3WZAF
B M6.3-100-3WZAF
B M10.5/ 3-200-1WZAF
B M10.5/ 3-150-1WZAF
B M10.5/ 3-200-1WZAF
B M10.5/ 3-150-1WZAF
B M10.5/ 3-120-1WZAF
B M10.5/ 3-100-1WZAF
B M10.5-200-3WZAF
B M10.5-100-3WZAF10.510.510.5 310.5 310.5 310.5 310.5 310.5 36.36.36.3 36.3 36.3 36.3 3
1.3In
Rated voltage(kV)
Rated utensil group rated voltage(kV)
Rated capacitance(kvar)
Rated current (A)
Capacitor warp
Allow steady state over-voltage
Allow steady state current
Shunt capacitor typeCapacitor quantityType
0~5% 1.1Un
TBBZ-A-220TBBZ-A-220JTBBZ-A-221TBBZ-A-221JTBBZ-A-310TBBZ-A-310JTBBZ-A-311TBBZ-A-311JTBBZ-A-320TBBZ-A-320JTBBZ-A-321TBBZ-A-321JTBBZ-A-410TBBZ-A-410JTBBZ-A-411TBBZ-A-411JTBBZ-A-420TBBZ-A-420JTBBZ-A-421TBBZ-A-421J
Remark: "" means what the type spec product has content in the item
11333366113333
TBBZ10-100ATBBZ10-200ATBBZ10-300ATBBZ10-360ATBBZ10-450ATBBZ10-600ATBBZ10-900ATBBZ10-1200ATBBZ6-100ATBBZ6-200ATBBZ6-300ATBBZ6-360ATBBZ6-450ATBBZ6-600A
1010101010101010666666
1002003003604506009001200100200300360450600
5.51116.519.824.73349.465.99.218.327.53341.254.9
Control physics: time,voltage
Time,voltage,power factor, reactive power
Close quarter control ,Remote measureRemote adjust
With communication interface,"4 remote"
Cold roll steel board crust
Stainless steel board crust
The controller is placed inside switch
The controller is placed in special control box
The metal fittings and line are placed for match set
Type spec
3 Using environment condition3.1 Environment air temperature3.2 Altitude : below 2000 m3.3 Wind speed 35m/s3.4 Sunlight radiate(most) is 0.1W/cm23.5 Earthquake: intensity is less than 8 degree3.6 Chemistry condition : there aren't any nocuous air and steam isnt electric and blast dustRemark : tableland type and special environment product will bargain on another fashion.
4 Main technology parameter Table 2
P34.
High Voltage Capacitor
5.1 main electric device collocate
The type and name of the installationBAM BFM high voltage shunt capacitor FLW(B)-12 special high voltage SF6 load switch to switch on-off capacitorYBK control power supply transformer
RW10-10 fall off type fuse
YH5WS zinc oxide arrester
WZK-1 high voltage reactive compensate controllerLZKW-10 high voltage current transformer outdoor
QuantityTable 211
3
3
11
Remark
The ratio is 10000/220 in 10kV line.The ratio is 6000/220 in 6kV line.
The type is YH5WS-17/50 in 10kV line.The type is YH5WS-10/30 in 10kV line.
The product of common 1 type isn't used
5.2.2 YBK control supply transformer
Rated voltage
10/0.22kV6/0.22kV
Rated capacitance
1kVA (Transient)150VA (Transient)
1 min power frequency patience voltage
High voltage side42kVHigh voltage side25kV
Patience voltage under thunder strike
75kV60kV
The most allow warp of secondary voltage
1%Low voltage side3kVLow voltage side3kV
Rated voltage (kV)
1 min power frequency patience voltage (kV)
Rated short time patience current availability value (kA)
Rated patiencecurrent peak value(kA)
Rated short circuit by switch current (kA)
Machine life (times)
Operating supply voltage
SF6 air rated press
Control box protecting grand
Rated current(A)
12100200
42 12.5kA, 4s 31.5 30000 AC220V0.05MPa (20) IP33
Patience voltage under thunder(kV)
75 31.5
5.2.3 WZK-1 high voltage reactive compensate controller
Rated voltage
220V
Rated current
5A
Power frequency patience voltage for 1 min
Measure precision of voltage and current
0.5%
Measure precision of reactive power
0.3%
Power consume
To substation To terminal of circuitry
Fall off fuse
Control supply transformer
Arrester
High voltage shunt capacitor
Control box
Current transformer
SF6 load switch
Arrester
35
00
~500
18
00
2250
When subscribe goods, please offer hereinafter information8.1 According to item 2, please give clear indication of type and spec.8.2 There is special demand element and parameter.8.3 The ratio of current transformer.
To substationTo terminal of circuitry
Fall off fuse
Control supply transformer
SF6 load switch
Shoring insulator
High voltage shunt capacitor
Control box
Arrester 18
00
~200
~350
0Current transformerArrester
8.4 Install fashion.8.5 The spec of pole (include length and tip diameter of the pole).8.6 The name and quantity of spare part.8.7 The time of deliver the goods and transport fashion.
7 Outline and placed dimensionThere are two install fashion in 600 kvar of the installation which are double pole and single pole . The double pole fashion is used on up 600 kvar (drawing 1 and 2)
Drawing 1 double poles install fashion
Drawing 2 single pole install fashion
8 subscribe goods notice
P36.
High Voltage Capacitor
TAL type Alternating Filter Capacitor Installation
in electric power,steel,metallurgy,chemical industry,coal mine,light industry,building materials and places where harmonic current comes out. The equipments work to absorb the harmonic current from harmonic sources, restrain harmonic, eliminate the pollution of electric harmonic. The TAL equipments operate in parallel with harmonic source, besides filtering, they can also compensate reactive power in the way of offering reactive power for system and increasing power factor.
TAL type alternating filter capacitor installations are used in 6~35kV electric system, mainly installed
4. Type Meaning and Specification
1. General Description
3. Application Ambient Conditions3.1 Installation: indoor/outdoor.
3.2 Altitude: 1000m.
3.3 Temperature range: -40+45.
3.4 Relative humidity: monthly mean850%.
3.5 Antipollution ability: creepage distance ratio of outward insulation25mm/kV (relative to highest
system running voltage). Increase the ratio in heavy pollution area.
3.6 No causticity gas, vapor, no inflammable gas, no blaze, no explosion risk, no frequent violent shake.
3.7 Biggest wind velocity: 35m/s
(consult us if the environment condition is special)
T A L - /
W: outdoor (if default: indoor)
Relay protection:
K: open delta protect;
C: voltage differential protect;
L: imbalance current protect;
Q: bridge current differential protect;
Y: imbalance voltage protect
Wiring:
A: single star B: double star
Unit capacitance (kvar)
Rated capacitance (kvar)
System voltage (kV)
Filter
AC
Installation
2. Executing Standards GB50227-2008 JB/T7111-1993 DL/T604-2009
P37.
High Voltage Capacitor
5. Main technology parameter5.1 Insulate level
Rated voltage of the installation
The patience voltage in frequency for 1min in primary circuit (RMS value)
The impact patience voltage[(1.25)/50s peak value] in primary circuit.
The patience voltage in frequency for 1min in secondary circuit (RMS value).
61035
324295
6075200
222
UnitkV Table 1
5.2 steady state over-voltage
Over-voltage in power frequency Most persist time Explain1.101.151.201.30
Long time30 min each 24 h5min1min
The most value of over-voltage isn't exceed 1.1 Un for long time.Adjust and fluctuate of system voltage.When light load, the voltage raise.When light load, the voltage raise.
Table 2
C
C type filter
C
L
R
RL
C
High frequency passage filter
LC
L
C
Double tuneSingle tune
C
L
Drawing 1 The electric connect line drawing of every type
P38.
High Voltage Capacitor
2. Type and Signification
1. ApplicationAll-Film High-Voltage Shunt Capacitors is suitable for using in power frequency AC power system with Rated voltage 1kV to increase power factor, improve voltage quality and reduce circuit losses.This product adopts double sided thin coarsing polypropylene film as solid dielectric, M/DBT or PEPE as liquid dielectric, and edge fold aluminum foil as plate electrode. It has advantages as less space and weight, lower losses, low temperature rise, fine self-discharge performance, long lifetime. It is available with internal or external fuses and discharge resistances in accordance with requirements.Standards: IEC60871-1 (2005), GB/T11024-2001
3.1 Rated voltage: 1~21kv ,AC.
3.2 Rated frequency: 50 Hz or 60Hz.
3.3 Rated capability: 20~500kvar.
3.4 Error of capacitance: -5%~+10%.
3.5 Tagof waste angle: 0.0003.
3.6 The highest allow over-voltage: 1.1Un.
3.7 The biggest over-current: 1.3In.
3.8 Discharge specialty: As supply stop, the voltage capacitor debase from2 Un to under 75V.
B M -- Z: TBBZ type on pole which is automatic switch on-off capacitorW: OutdoorPhase numberRated capacitancekvar Rated voltagekVAll film mediumA:DBT/PEPE F: PXEShunt capacitor
B M all film high voltage shunt capacitorFA
3. Main technology parameter
4. Environment condition4.1 BAM: -40~+45, BFM: -25~+50.
4.2 Altitude1000m.
4.3 Environment condition : No violent mechanical vibration no erode air and vapor, no electric dust.
5. Main technology parameterSingle phase capacitor data table
TypeRated voltage(kV)
No.
A B D F L h1 h H
Rated current(A)
Rated frequency(Hz)
Rated capacitance(F)
Oil weight (kg)
Fig No.
Connect line head
Weight(kg)
Dimension(mm)
BAM6.3-50-1(W)BAM6.3-100-1(W)BAM6.3-150-1(W)BAM6.3-167-1(W)BAM6.3-200-1(W)BAM6.3-250-1(W)BAM6.3-300-1(W)BAM6.3-334-1(W)BAM6.3-500-1(W)BAM6.6/3-50-1(W)BAM6.6/3-100-1(W)
6.36.36.36.36.36.36.36.36.36.6/36.6/3
7.915.923.826.531.839.747.653.079.413.126.3
5050505050505050505050
4.018.0212.0313.416.0420.0524.0626.7940.1010.9621.92
5.67.9101112151617245.78.1
1827353844536066911827
385385385385385385385385440385385
150150150173173173173173200150150
425425425425425425425425480425425
250250250250250250250250300250250
465465465465465465465465520465465
9023028028028035045052052090230
200320430410480580670730790200320
370490600580650750840900960370490
M12M12M12M12M12M16M16M16M16M12M12
11222222211
12
4
567891011
3
P39.
High Voltage Capacitor
Continue table
Type specRated voltage(kV)
No.A B D F L h1 h H
Rated current(A)
Rated frequency(Hz)
Rated capacitance(F)
Oil weight (kg)
DrawingConnect ine head
Weight(kg)
Outline dimension (mm)
BAM6.6/3-150-1(W)BAM6.6/3-167-1(W)BAM6.6/3-200-1(W)BAM6.6/3-250-1(W)BAM6.6/3-300-1(W)BAM6.6/3-334-1(W)BAM6.6/3-500-1(W)BAM10.5/3-50-1WBAM10.5/3-100-1WBAM10.5/3-150-1WBAM10.5/3-167-1WBAM10.5/3-200-1WBAM10.5/3-250-1WBAM10.5/3-300-1WBAM10.5/3-334-1WBAM10.5/3-500-1WBAM11/3-50-1WBAM11/3-100-1WBAM11/3-150-1WBAM11/3-167-1WBAM11/3-200-1WBAM11/3-250-1WBAM11/3-300-1WBAM11/3-334-1WBAM11/3-500-1WBAM11-50-1WBAM11-100-1WBAM11-150-1WBAM11-167-1WBAM11-200-1WBAM11-250-1WBAM11-300-1WBAM11-334-1WBAM11-500-1WBAM19-334-1WBAM20-334-1WBAM21-334-1W
6.6/36.6/36.6/36.6/36.6/36.6/36.6/310.5/310.5/310.5/310.5/310.5/310.5/310.5/310.5/310.5/311/311/311/311/311/311/311/311/311/3111111111111111111192021
39.443.852.565.678.787.7131.28.316.524.827.633.041.349.555.182.57.915.723.626.331.539.447.252.678.74.69.1013.715.218.222.827.330.445.517.616.715.9
50505050505050505050505050505050505050505050505050505050505050505050505050
32.8836.6143.8454.8165.7773.22109.614.338.6612.9914.4717.3221.6525.9828.9343.313.957.8911.8413.1815.7819.7323.6826.3639.461.322.633.954.395.266.587.898.7913.152.952.662.41
10111315161724681011121516172468101112151617246810101214161723292929
36394553616692202937404654626793202937404654626792192837394554616692959595
385385385385385385440385385385385385385385385440385385385385385385385385440385385385385385385385385440680680680
150173173173173173200150150150173173173173173200150150150173173173173173200150150150173173173173173200175175175
425425425425425425480425425425425425425425425480425425425425425425425425480425425425425425425425425480720720720
250250250250250250300250250250250250250250250300250250250250250250250250300250250250250250250250250300450450450
465465465465465465520465465465465465465465465520465465465465465465465465520465465465465465465465465520760760760
280280280350450520520902302802802803504505205209023028028028035045052052090230280280280350450520520400400400
430410480580670730790200320430410480580670730790200320430410480580670730790200320430410480580670730790530530530
600580650750840900960470590700680750850940100010604705907006807508509401000106047059070068075085094010001060850850850
M16M16M16M16M16M16M16M12M12M12M12M12M16M16M16M16M12M12M12M12M12M16M16M16M16M12M12M12M12M12M12M12M12M16M16M16M16
2222222112222222112222222112222222222
121314
16
1718192021222324252627282930313233343536373839404142434445464748
15
P40.
High Voltage Capacitor
TypeRated voltage(kV)
No.A B D F L h1 h H
Rated current(A)
Rated frequency(Hz)
Rated capacitance(F)
Oil weight (kg)
DrawingConnect ine head
Weight(kg)
Dimension (mm)
505050505050505050505050505050505050505050505050505050505050505050505050505050505050
3 phase capacitor data table
M12M12M12M12M12M12M16M16M12M12M12M12M12M12M12M12M16M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12
390390600600600600600640390390390600600600600600640390390390390390390600600600600640390390390390390390600600600600390600600640
116126113135173200200200116116126113135173200200200116116116116116126113135173200200116116116116116126113135173200126135200200
430430640640640640640680430430430640640640640640680430430430430430430640640640640680430430430430430430640640640640430640640680
275275250250250250250260275275275250250250250250260275275275275275275250250250250260275275275275275275250250250250275250250260
470470680680680680680720470470470680680680680680720470470470470470470680680680680720470470470470470470680680680680470680680720
150230280280280280330330100150230280280280280330330100100150170230230280280280280330100100150170230230280280280280230280280330
270400440440440440490490220270400440440440440490490220240270310380400440440440440490220240270310380400440440440440400440440490
490620610610610610660660440490620610610610610660660540560590630700720710710710710760540560590630700720710710710710720710710760
BAM6.3-50-3WBAM6.3-100-3WBAM6.3-150-3WBAM6.3-200-3WBAM6.3-250-3WBAM6.3-300-3WBAM6.3-350-3WBAM6.3-400-3WBAM6.6-30-3WBAM6.6-50-3WBAM6.6-100-3WBAM6.6-150-3WBAM6.6-200-3WBAM6.6-250-3WBAM6.6-300-3WBAM6.6-350-3WBAM6.6-400-3WBAM10.5-30-3WBAM10.5-40-3WBAM10.5-50-3WBAM10.5-60-3WBAM10.5-80-3WBAM10.5-100-3WBAM10.5-150-3WBAM10.5-200-3WBAM10.5-250-3WBAM10.5-300-3WBAM10.5-400-3WBAM11-30-3WBAM11-40-3WBAM11-50-3WBAM11-60-3WBAM11-80-3WBAM11-100-3WBAM11-150-3WBAM11-200-3WBAM11-250-3WBAM11-300-3WBAM12-100-3WBAM12-200-3WBAM12-300-3WBAM12-400-3W
6.36.36.36.36.36.36.36.36.66.66.66.66.66.66.66.66.610.510.510.510.510.510.510.510.510.510.510.51111111111111111111112121212
4.69.213.818.322.927.532.136.72.64.48.813.117.521.926.330.635.01.72.22.83.34.45.58.31113.816.522.01.62.12.63.24.25.37.910.513.115.84.89.614.419.3
4.018.0212.0316.0420.0524.0628.0732.082.193.657.3110.9614.6118.2721.9225.5829.230.8661.161.441.732.312.894.335.777.228.6611.550.791.051.321.582.12.633.955.266.587.892.214.426.638.84
223241506674828719223244506574828721222426313446536577912122242631344653657734537690
711131519222424881112152022242577889101215182023778810101215192110142124
445666664445666664444445666644444456664666
12
4
56789101112
3
1314
16
1718192021222324252627282930313233343536373839404142
15
P41.
High Voltage Capacitor
TypeNo.A B D F L h1 h H
Rated current(A)
Rated frequency(Hz)
Rated capacitance(F)
Oil weight (kg)
DrawingConnect line head
Weight(kg)
Dimension (mm)
50505050505050505050505050505050505050
12
4
56789101112
3
1314
1516171819
Remark:1. BFM type is same with BAM product data in this table.2. Discharge resister is usually fixed in 3 phase capacitor and single phase capacitor isn't fixed resister if there isn't the demand.3. The single capacitor Upward 150KV may be fixed fuse if there is other demand.
M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12M12
385385385385385385390390390390390600600600600640640640640
150150150150173173116116116126126113123123135135145173173
425425425425425425430430430430430640640640640680680680680
250250250250250250275275275275275250250250250260260260260
465465465465465465470470470470470680680680680720720720720
320370400430410480240310380400460440440440440440440440440
590640670700680750560630700720780710710710710710710710710
BAM10.5/3-100-1WZBAM10.5/3-120-1WZBAM10.5/3-134-1WZBAM10.5/3-150-1WZBAM10.5/3-167-1WZBAM10.5/3-200-1WZBAM10.5-40-3WZBAM10.5-60-3WZBAM10.5-80-3WZBAM10.5-100-3WZBAM10.5-120-3WZBAM10.5-150-3WZBAM10.5-160-3WZBAM10.5-180-3WZBAM10.5-200-3WZBAM10.5-220-3WZBAM10.5-240-3WZBAM10.5-260-3WZBAM10.5-280-3WZ
16.519.822.124.827.633.02.23.34.45.56.68.38.89.91112.113.214.315.4
8.6610.3911.6112.9914.4717.321.161.732.312.893.464.334.625.205.776.356.937.518.08
29323537404622263134384649505357606969
89910111278910111213131515162120
2222227777766666666
Shunt Capacitor for Load Switch
Drawing 1
6. Outline and fixing dimension drawing
h1h
H
F
BA
D
L
230230230280280280100170230230280280280280280280280280280
Rated voltage(kV)
10.5/310.5/310.5/310.5/310.5/310.5/310.510.510.510.510.510.510.510.510.510.510.510.510.5
P42.
High Voltage Capacitor
Drawing 2
h1h
H
F
BA
D
L
Drawing 3
h1
h
H
F
BA
D
L
Drawing 4
h1
h
H
F
BA
D
L
F
P43.
High Voltage Capacitor
Drawing 5
h1
h
H
F
BA
D
L
F
Drawing 6
h1
h
H
F
BA
D
L
F
Drawing 7
h1
h
H
F
BA
D
L
F
P44.
High Voltage Capacitor
T D&
2012-016EN0326
Division Representative E-mailTel
International Business: Attributed to our reliable quality and perfect after-sales service, CHINT T&D has been relied on and entrusted with by many of our clients around the world. We will continue to supply best products and try hard to win more compliments through our best service.
For inquiries, further interests for products cooperation, partnership, international alliance,investment discussion with us, please contact the following representatives.
South Asia
Latin America
Southeast Asia(ASEAN)
Oceania
Middle East
North America
Tracy Li [email protected]
Bill Han
Xufeng Jiang
(+86) 21 6777 7777 ext.80911
(+86) 21 6777 7777 ext.80990
Selina Peng
Lucy Zou
(+86) 21 6777 7777 ext.80917
(+86) 21 6777 7777 ext.80906
Lucy Zou (+86) 21 6777 7777 ext.80906 [email protected]
Charley Liu (+86) 21 6777 7777 ext.80995 [email protected]
Selina Peng (+86) 21 6777 7777 ext.80917 [email protected]
(+86) 21 6777 7777 ext.80992
(+86) 21 6777 7777 ext.80981 [email protected] Yang
Europe
Russian-speaking countries (CIS)
Africa / French language speaking countries
Myanmar / Pakistan
Industrial End User Division
York Zhi
David Liu
Charles Xu
Yin Zhang
(+86) 21 6777 7777 ext.80930
(+86) 21 6777 7777 ext.80925
(+86) 21 6777 7777 ext.80963
(+86) 21 6777 7777 ext.80959
(+86) 21 6777 7777 ext.80981 [email protected] Yang
General Manager
Electric Power Components andAutomation Division
Address:
The contents and data in this catalogue are for reference only. The real orderrequirements and technical agreements shall prevail. The catalogue is subject to change without further notice. The latest edition is recommended. CHINT reserves the right of interpretation.
International Business Department855 Wenhe Road, Songjiang DistrictShanghai 201614, ChinaTel: (+86) 21 6777 7777 ext. 80952Fax: (+86) 21 6777 7999Http://en.chintelectric.com