56
www.andritz.com/pumps High-pressure pumps Series HP43

High-pressure pumps - Series HP45Multi-stage high pressure pumps for water supply, irrigation and industrial applications, for hot and cold water circulation, fire fight- ... lubricated

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

www.andritz.com/pumps

High-pressure pumpsSeries HP43

3

Description / ApplicationMulti-stage high pressure pumps for water supply, irrigation and

industrial applications, for hot and cold water circulation, fire fight-

ing, boiler feed and pressure boosting installations. Suitable for

all clean or slightly dirty non-corrosive liquids up to a viscosity of

150 mm²/s (cSt).

Operating range

Nominal branch diameter DN 40-200

Capacity Q up to 850 m3/h

Head H up to 630 m

Operating pressure p up to 63 bar

Liquid temperature t -20°C up to +140°C

Speed n up to 3600 rpm

DesignationHP 100-240.1/5/E + 22/4

Nominal branch diameter [mm]

Nominal impeller diameter [mm]

Hydraulics ID

Nominal power P2 [kW]

Number of poles

Series

Number of stages

Arrangement

Example

General

Product advantages

� Numerous horizontal and vertical models for an efficient buil-

ding design.

� Flexible arrangement of suction- and delivery branch.

� Numerous hydraulic units per model size guarantee a design

at the optimal operating point.

� High efficiencies owing to optimized hydraulics.

� Optimal adaptability to the medium to be pumped owing to a

variety of material and sealing versions.

� Pump shaft protected along its entire length by means of

impeller hubs and sleeves.

� Balancing of the axial thrust by means of balancing piston (at

high pressure).

4

Arrangements

Arrangement A1 and E1

Pump arranged horizontally. Radial suction and delivery connec-

tions. On the suction and delivery sides, shaft mounted in grease

lubricated ball bearings outside the pump body. Drive on suction

side with anti-clockwise rotation, seen from drive end. Pump and

motor mounted on a common base plate, connectec by a flexible

coupling.

Arrangement A2 and E2

Pump arranged horizontally. Radial suction and delivery connec-

tions. On delivery side, shaft mounted outside the pump body

in grease lubricated ball bearings, and on suction side rotating

in a sleeve bearing lubricated by the pumped medium. Drive on

delivery side with clockwise rotation, seen from drive end. Pump

and motor mounted on a common base plate, connectec by a

flexible coupling.

Arrangement A3 and E3

Pump arranged horizontally. Radial suction and delivery connec-

tions. On the suction and delivery sides, shaft mounted in grease

lubricated ball bearings outside the pump body. Drive on delivery

side with clockwise rotation, seen from drive end. Pump and mo-

tor mounted on a common base plate, connectec by a flexible

coupling.

Arrangement AX

Pump arranged horizontally. Axial suction connection, radial de-

livery connection. On delivery side, shaft mounted outside the

pump body in grease lubricated ball bearings, and on suction

side rotating in a sleeve bearing situated within the suction bran-

ch lubricated by the pumped medium. Drive on delivery side with

clockwise rotation, seen from drive end. Pump and motor moun-

ted on a common base plate, connectec by a flexible coupling.

Particularly favourable flow pattern towards the first stage impeller

and consequently better suction performance.

Arrangement SPump arranged vertically. Radial suction and

delivery connections. On the suction side, shaft

mounted in a sleeve bearing lubricated by the

pumped medium, and on the delivery side

mounted in grease lubricated ball bearings.

Drive on delivery side with clockwise rotation,

seen from drive end. Pump and motor connec-

ted via a flexible coupling. Particulary space-

saving, easy-to-install design.

5

ConstuctionMulti-stage ring section pump of robust construction with extra

large shaft section for vibration-free running. For high output pres-

sures additional axial thrust balancing is provided by a balancing

piston mounted on pump shaft. All wearing parts are renewable

without additional work on the casing parts. Shaft sealing either

with mechanical seal or gland packing. Bearing housings are pro-

tected against the ingress of spray water by means of lip seals.

Under difficult suction conditions (low NPSH-available), the pump

can be provided with an axial inlet for cavitation-reducing flow

entry pattern into the first stage impeller.

ImpellersAt least two types of impellers with matching diffuser are available

for each pump frame. Therefore operation within the range of op-

timum efficiency is possible for the required output conditions. If

an abrasive medium is being pumped, the slip face and hub sec-

tion of the impeller can be protected by renewable rings / bushes

in wear resistant materials.

Shaft and bearingsIn all the pumps the shaft is protected against wear and corrosion

over its entire length by shaft wear sleeves, especially in the area

of the shaft seal (mechanical seal or gland packing) and the sleeve

bearings in arrangement AX and S. In case of pumps in arrange-

ment A1 and A3, the shaft is mounted outside the pump body in

grease lubricated ball bearings (a radial deep groove ball bearing

on the suction side and a fixed bearing with paired angular con-

tact ball bearings on the delivery side).

On arrangement A2, AX and S, the shaft is carried in a shielded

sleeve bearing lubricated by the pumped medium on the suction

side and, on the delivery side, by grease lubricated angular con-

tact ball bearings. All rolling bearings are protected by lip seals.

Shaft sealingIn the standard version the shaft is sealed by mechanical seal acc.

to DIN 24960. A shaft sealing by gland packing is available as an

option. The packing rings form a seal with a renewable shaft slee-

ve which protects the shaft against wear.

According to requirements following mechanical seals may be

used: � single acting unbalanced mechanical seal � single acting balanced mechanical seal � cartridge seal

Mechanical seals are always mounted on a shaft wear sleeve in

stainless steel.

Axial thrust compensationIn pumps with a small number of stages the ball bearings (fixed

bearings) absorb the axial thrust. In pumps with a larger number

of stages, the axial thrust is equalised by means of a balancing

piston mounted on the shaft in the area of the delivery housing.

Slip facesIn order to prevent wear in the slip face and hub area as far as

possible interchangeable wear-resisting casing rings and neck

bushes are fitted in the housing. The slip faces of the impellers

can also be protected by renewable slip rings.

CouplingConnection between pump and IEC standard motor by flexible

coupling N-Eupex, type B.

Drive � In case of horizontal arrangement by IEC standard motor in

form B3 with supporting feet. � In case of vertical arrangement by IEC standard motor in form

V1, with flange connection according to DIN 42948.

Technical details

6

Branch positionArrangement A1 and E1, horizontal (standard)

� Drive at suction side. � Rotation direction of pump shaft is anti-clockwise, seen from

drive end. � Branch position by standard arrangement L3/0. � Suction and delivery branch to same direction is possible from

3 stages or more.

L3/0 L3/3 L3/9* L9/0 L9/3*

L9/9 L0/0* L0/3 L0/9

* possible from 3 stages

Arrangement A2, E2, A3 and E3, horizontal � Drive at delivery side. � Rotation direction of pump shaft is clockwise, seen from drive

end. � Branch position by standard arrangement R3/0. � Suction and delivery branch to same direction is possible from

3 stages or more.

R3/0 R3/3 R3/9* R9/0 R9/3*

R9/9 R0/0* R0/3 R0/9

* possible from 3 stages

Arrangement AX, horizontal � Drive at delivery side. � Rotation direction of pump shaft is clockwise, seen from drive

end. � Branch position by standard arrangement R4/0.

R4/0 R4/3 R4/9

Arrangement S, vertical � Drive at delivery side. � Rotation direction of pump shaft is clockwise, seen from drive

end. � Branch position by standard arrangement R9/3. � Suction and delivery branch to same direction is possible from

3 stages or more.

R9/3 R9/6 R9/0 R9/9*

* possible from 3 stages

Technical details

7

Selection chart

This chart allows a provisional selection of the pump type most

suitable for a given set of operating conditions. In certain cases

it may be possible to use the next smaller pump type and this

possibility should be included in the final selection. For an exact

pump selection our individual characteristic curves as well as our

pump selection software WinPump are available.

40

5

6

8

10

20

30

40

50

60

80

100

200

300

400

[l/s]

[Imp.gpm]

[US.gpm]

[ft]

20

30

40

50

60

80

100

200

300

400

500

600

800

1000

[m]

20 30 40 50 60 80 100

50 60 80 100 200 300 400 500 600

300 400 500 600 800 1000 2000

300 400 500 600 800 1000 2000

[m³/h]

Speed 1150 rpm

40

5

6

8

10

20

30

40

50

60

80

100

200

300

400

[l/s]

[Imp.gpm]

[US.gpm]

[ft]

20

30

40

50

60

80

100

200

300

400

500

600

800

1000

[m]

20 30 40 50 60 80 100

50 60 80 100 200 300 400 500 600[m³/h]

300 400 500 600 800 1000 2000

300 400 500 600 800 1000 2000

Speed 980 rpm

50Hz

60Hz

8

Selection chart

This chart allows a provisional selection of the pump type most

suitable for a given set of operating conditions. In certain cases

it may be possible to use the next smaller pump type and this

possibility should be included in the final selection. For an exact

pump selection our individual characteristic curves as well as our

pump selection software WinPump are available.

10

5

6

8

10

20

30

40

50

60

80

100

200

300

400

500

600

[l/s] 4

[Imp.gpm]

[US.gpm]

[ft]

20

30

40

50

60

80

100

200

300

400

500

600

800

1000

5 6 8 10 20 30 40 50 60 80 100 200

20 30 40 50 60 80 100 200 300 400 500 600 800[m³/h]

80 100 200 300 400 500 600 800 1000 2000 3000

80 100 200 300 400 500 600 800 1000 2000

[m]

Speed 1760 rpm

5

6

8

10

20

30

40

50

60

80

100

200

300

400

500

[Imp.gpm] 50

[US.gpm] 60

[ft]

20

30

40

50

60

80

100

200

300

400

500

600

800

1000

[l/s] 5 303 4 20 50406 108 60 80 100

8 10 20 30 50 100 200 300 400 600[m³/h]

60 80 100 200 300 400 500 600 800 1000 2000

80 100 200 300 400 500 600 800 1000 2000

[m]

40 60 80

Speed 1450 rpm

50Hz

60Hz

9

Selection chart

This chart allows a provisional selection of the pump type most

suitable for a given set of operating conditions. In certain cases

it may be possible to use the next smaller pump type and this

possibility should be included in the final selection. For an exact

pump selection our individual characteristic curves as well as our

pump selection software WinPump are available.

20

30

40

50

60

70

80

90100

200

300

400

500

600

[l/s]

[Imp.gpm]

[US.gpm]

[ft]

200

300

400

500

600

700

800

9001000

10 20 30 40 50 60 80 100 2008

30 40 50 60 80 100 200 300 400 500 800600[m³/h]

[m]

200 300 400 500 600 800 1000 2000 3000

200 300 400 500 600 800 1000 2000 3000

Speed 3600 rpm

20

20

30

40

50

60

70

8090

100

200

300

400

500

600

[l/s]

[Imp.gpm]

[US.gpm]

[ft]

80

100

200

300

400

500

600

800

1000

10 20 30 40 50 60 80 100 2006 8

30 40 50 60 80 100 200 300 400 500 600 800[m³/h]

[m]

100 200 300 400 500 600 800 1000 2000 3000

100 200 300 400 500 600 1000800 2000

Speed 2950 rpm

50Hz

60Hz

10

Performance curveType 40-160.1

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0 1 1.5 2 2.5 3 3.5 4 4.5 5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 15 20 25 30 35 40 45 50 55 60 65 70 75 80

0 15 20 25 30 35 40 45 50 55 60 65

0 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0 1 1.5 2 2.5 3 3.5 4 4.5 5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 50 75 100 125 150 175

0 25 50 75 100 125

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

Speed 1450 rpm Speed 2950 rpm

65917 65919

50Hz

11

Performance curveType 40-160.2

0

15

30

45

60

75

90

105

120

135

0

75

150

225

300

375

0 20 30 40 50 60 70 80 90 100

0 20 30 40 50 60 70 80

0 4 6 8 10 12 14 16 18 20 22 24

0 1 2 3 4 5 6

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 4 6 8 10 12 14 16 18 20 22 24

0 1 2 3 4 5 6

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

0

2

4

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0

0 10 15 20 25 30 35 40 45 50

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 50 75 100 125 150 175 200

0 50 75 100 125 150 175

0 10 15 20 25 30 35 40 45 50

0 2.5 5 7.5 10 12.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

Speed 1450 rpm Speed 2950 rpm

65921 65923

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

12

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 15 20 25 30 35 40 45 50 55 60 65 70 75 80

0 15 20 25 30 35 40 45 50 55 60 65

0 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0 1 1.5 2 2.5 3 3.5 4 4.5 5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

0 1 1.5 2 2.5 3 3.5 4 4.5 5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

1

3

5

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 50 75 100 125 150 175

0 25 50 75 100 125

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

Performance curveType 40-160.3

Speed 1450 rpm Speed 2950 rpm

65925 65927

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

13

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 20 30 40 50 60 70 80 90 100

0 20 30 40 50 60 70 80

0 4 6 8 10 12 14 16 18 20 22 24

0 1 2 3 4 5 6

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 4 6 8 10 12 14 16 18 20 22 24

0 1 2 3 4 5 6

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

2

4

6

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0

0 10 15 20 25 30 35 40 45 50

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 50 75 100 125 150 175 200

0 50 75 100 125 150 175

0 10 15 20 25 30 35 40 45 50

0 2.5 5 7.5 10 12.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

Performance curveType 40-160.4

Speed 1450 rpm Speed 2950 rpm

6593165929

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

14

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 30 40 50 60 70 80 90 100 110 120 130 140

0 20 30 40 50 60 70 80 90 100 110

0 6 8 10 12 14 16 18 20 22 24 26 28 30 32

0 2 3 4 5 6 7 8

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 6 8 10 12 14 16 18 20 22 24 26 28 30 32

0 2 3 4 5 6 7 8

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

2

4

6

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 10 15 20 25 30 35 40 45 50 55 60 65

0 2.5 5 7.5 10 12.5 15 17.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 50 75 100 125 150 175 200 225 250 275

0 50 75 100 125 150 175 200 225

0 10 15 20 25 30 35 40 45 50 55 60 65

0 2.5 5 7.5 10 12.5 15 17.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

09

08

07

06

05

04

03

02

01

Performance curveType 50-195.1

Speed 1450 rpm Speed 2950 rpm

65933 65935

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

15

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 50 75 100 125 150 175 200

0 50 75 100 125 150

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

3

5

7

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 150 200 250 300 350 400

0 100 150 200 250 300

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

09

08

07

06

05

04

03

02

01

Performance curveType 50-195.2

Speed 1450 rpm Speed 2950 rpm

65937 65939

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

16

5

15

25

35

45

55

65

75

85

95

105

115

125

135

145

155

165

175

185

195

205

215

225

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 25 50 75 100 125 150

0 25 50 75 100 125

0 5 10 15 20 25 30 35

0 2.5 5 7.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 5 10 15 20 25 30 35

0 2.5 5 7.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

3

7

11

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 10 20 30 40 50 60 70

0 5 10 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 50 100 150 200 250 300

0 50 100 150 200 250

0 10 20 30 40 50 60 70

0 5 10 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

09

08

07

06

05

04

03

02

01

Performance curveType 50-195.3

Speed 1450 rpm Speed 2950 rpm

65941 65943

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

17

5

15

25

35

45

55

65

75

85

95

105

115

125

135

145

155

165

175

185

195

205

215

225

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 50 75 100 125 150 175 200

0 50 75 100 125 150

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

4

9

14

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 100 150 200 250 300 350 400

0 100 150 200 250 300

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

09

08

07

06

05

04

03

02

01

Performance curveType 50-195.4

Speed 1450 rpm Speed 2950 rpm

65945 65947

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

18

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 50 75 100 125 150 175 200 225 250

0 50 75 100 125 150 175 200

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

4

8

12

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1 2

0 20 30 40 50 60 70 80 90 100 110 120

0 5 10 15 20 25 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 150 200 250 300 350 400 450 500

0 100 150 200 250 300 350 400

0 20 30 40 50 60 70 80 90 100 110 120

0 5 10 15 20 25 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

08

07

06

05

04

03

02

01

Performance curveType 80-220.1

Speed 1450 rpm Speed 2950 rpm

65949 65951

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

19

0

15

30

45

60

75

90

105

120

135

150

0

75

150

225

300

375

450

0 75 100 125 150 175 200 225 250 275 300 325 350

0 50 75 100 125 150 175 200 225 250 275

0 15 20 25 30 35 40 45 50 55 60 65 70 75 80

0 5 7.5 10 12.5 15 17.5 20

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

1

2

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 15 20 25 30 35 40 45 50 55 60 65 70 75 80

0 5 7.5 10 12.5 15 17.5 20

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

5

10

15

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 1 2

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 200 300 400 500 600 700 800

0 200 300 400 500 600

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

08

07

06

05

04

03

02

01

Performance curveType 80-220.2

Speed 1450 rpm Speed 2950 rpm

65053 65955

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

20

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 50 75 100 125 150 175 200 225 250 275

0 50 75 100 125 150 175 200 225

0 10 15 20 25 30 35 40 45 50 55 60 65

0 2.5 5 7.5 10 12.5 15 17.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 10 15 20 25 30 35 40 45 50 55 60 65

0 2.5 5 7.5 10 12.5 15 17.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

5

15

25

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1 2

0 20 30 40 50 60 70 80 90 100 110 120 130

0 5 10 15 20 25 30 35

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 100 150 200 250 300 350 400 450 500 550

0 100 150 200 250 300 350 400 450

0 20 30 40 50 60 70 80 90 100 110 120 130

0 5 10 15 20 25 30 35

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

08

07

06

05

04

03

02

01

Performance curveType 80-220.3

Speed 1450 rpm Speed 2950 rpm

65957 65959

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

21

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 100 150 200 250 300 350 400

0 100 150 200 250 300

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

10

20

30

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1 2

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

575

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

1875

0 200 300 400 500 600 700 800

0 200 300 400 500 600

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

08

07

06

05

04

03

02

01

Performance curveType 80-220.4

Speed 1450 rpm Speed 2950 rpm

65961 65963

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

22

5

15

25

35

45

55

65

75

85

95

105

115

125

135

145

155

165

175

185

195

205

215

225

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 100 150 200 250 300 350 400 450 500

0 100 150 200 250 300 350 400

0 20 30 40 50 60 70 80 90 100 110 120

0 5 10 15 20 25 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 20 30 40 50 60 70 80 90 100 110 120

0 5 10 15 20 25 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

10

20

30

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 1 2 3

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

30

50

70

90

110

130

150

170

190

210

230

250

270

290

310

330

350

370

390

410

430

450

470

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

1500

0 200 300 400 500 600 700 800 900

0 200 300 400 500 600 700 800

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 100-240.1

Speed 1450 rpm Speed 2950 rpm

65965 65967

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

23

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 100 150 200 250 300 350 400 450 500 550 600 650

0 100 150 200 250 300 350 400 450 500 550

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

2

4

6

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 400 600 800 1000 1200 1400

0 200 400 600 800 1000

0 80 120 160 200 240 280 320

0 20 40 60 80

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

20

30

40

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 2 4

0 80 120 160 200 240 280 320

0 20 40 60 80

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

07

06

05

04

03

02

01

Performance curveType 100-240.2

Speed 1450 rpm Speed 2950 rpm

65969 65971

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

24

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 100 150 200 250 300 350 400 450

0 100 150 200 250 300 350 400

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

3

6

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

10

30

50

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 1 2 3

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 200 300 400 500 600 700 800 900

0 200 300 400 500 600 700 800

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 100-240.3

Speed 1450 rpm Speed 2950 rpm

65973 65975

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

25

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 100 150 200 250 300 350 400 450 500 550 600 650

0 100 150 200 250 300 350 400 450 500 550

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

2

5

8

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

20

40

60

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 2 4

0 80 120 160 200 240 280 320

0 20 40 60 80

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 400 600 800 1000 1200 1400

0 200 400 600 800 1000

0 80 120 160 200 240 280 320

0 20 40 60 80

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 100-240.4

Speed 1450 rpm Speed 2950 rpm

65977 65979

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

26

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 200 300 400 500 600 700 800

0 200 300 400 500 600 700

0 40 60 80 100 120 140 160 180 200

0 10 20 30 40 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

4

8

12

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2 3

0 40 60 80 100 120 140 160 180 200

0 10 20 30 40 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 500 750 1000 1250 1500 1750 2000

0 500 750 1000 1250 1500

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

30

60

90

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 2 3 4 5 6 7

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

05

04

03

02

01

Performance curveType 125-260.1

Speed 1450 rpm Speed 2950 rpm

65981 65983

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

27

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 200 300 400 500 600 700 800 900 1000 1100 1200

0 200 300 400 500 600 700 800 900 1000

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

5

10

15

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 1 2 3 4

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 500 750 1000 1250 1500 1750 2000 2250 2500

0 500 750 1000 1250 1500 1750 2000

0 100 150 200 250 300 350 400 450 500 550 600

0 25 50 75 100 125 150

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

40

80

120

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 2 3 4 5 6 7 8 9 10

0 100 150 200 250 300 350 400 450 500 550 600

0 25 50 75 100 125 150

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

05

04

03

02

01

Performance curveType 125-260.2

Speed 1450 rpm Speed 2950 rpm

65985 65987

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

28

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

0 250 500 750 1000 1250 1500

0 250 500 750 1000 1250

0 50 100 150 200 250 300 350

0 25 50 75

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

5

15

25

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 1 2 3 4 5

0 50 100 150 200 250 300 350

0 25 50 75

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

575

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

1875

0 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000

0 500 750 1000 1250 1500 1750 2000 2250 2500

0 100 150 200 250 300 350 400 450 500 550 600 650 700

0 25 50 75 100 125 150 175

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

100

200

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 2 3 4 5 6 7 8 9 10 11

0 100 150 200 250 300 350 400 450 500 550 600 650 700

0 25 50 75 100 125 150 175

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

04

03

02

01

Performance curveType 150-305.1

Speed 1450 rpm Speed 2950 rpm

65989 65991

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

29

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 500 750 1000 1250 1500 1750 2000

0 500 750 1000 1250 1500

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

20

30

10

20

30

40

50

60

70

80

90

0

3

6

9

0

15

0 2 3 4 5 6 7

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

575

600

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

1875

0 1000 1500 2000 2500 3000 3500 4000

0 1000 1500 2000 2500 3000

0 200 300 400 500 600 700 800 900

0 50 100 150 200 250

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

100

200

300

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 3 4 5 6 7 8 9 10 11 12 13 14

0 200 300 400 500 600 700 800 900

0 50 100 150 200 250

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

04

03

02

01

Performance curveType 150-305.2

Speed 1450 rpm Speed 2950 rpm

65993 65995

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

30

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 250 500 750 1000 1250 1500

0 250 500 750 1000 1250

0 50 100 150 200 250 300 350

0 25 50 75

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

5

10

15

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2 3 4 5

0 50 100 150 200 250 300 350

0 25 50 75

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 500 750 1000 1250 1500 1750 2000 2250

0 500 750 1000 1250 1500 1750 2000

0 100 150 200 250 300 350 400 450 500 550

0 25 50 75 100 125 150

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

20

40

60

10

20

30

40

50

60

70

80

90

0

3

6

9

0

15

0 2 3 4 5 6 7 8 9

0 100 150 200 250 300 350 400 450 500 550

0 25 50 75 100 125 150

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 200-360.1

Speed 980 rpm Speed 1450 rpm

65997 65999

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

31

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

0

75

150

225

300

375

450

525

600

675

750

825

900

975

0 500 750 1000 1250 1500 1750 2000

0 500 750 1000 1250 1500 1750

0 100 150 200 250 300 350 400 450 500

0 25 50 75 100 125

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

5

15

25

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 2 3 4 5 6 7 8

0 100 150 200 250 300 350 400 450 500

0 25 50 75 100 125

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250

0 500 750 1000 1250 1500 1750 2000 2250 2500 2750

0 150 200 250 300 350 400 450 500 550 600 650 700 750

0 50 75 100 125 150 175 200

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

20

40

60

10

20

30

40

50

60

70

80

90

0

3

6

9

0

15

0 2 3 4 5 6 7 8 9 10 11 12

0 150 200 250 300 350 400 450 500 550 600 650 700 750

0 50 75 100 125 150 175 200

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 200-360.2

Speed 980 rpm Speed 1450 rpm

66001 66003

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

50Hz

32

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 4 6 8 10 12 14 16 18 20 22

0 1 2 3 4 5 6

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

0

50

100

150

200

250

300

350

400

450

500

550

600

650

0 20 30 40 50 60 70 80 90

0 20 30 40 50 60 70 80

0 4 6 8 10 12 14 16 18 20 22

0 1 2 3 4 5 6

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

2

4

6

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 50 75 100 125 150 175 200

0 50 75 100 125 150

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 40-160.1

Speed 1760 rpm Speed 3600 rpm

65918 65920

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

33

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

0

50

100

150

200

250

300

350

400

450

500

550

600

650

0 25 50 75 100 125

0 25 50 75 100

0 5 10 15 20 25 30

0 2.5 5 7.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 5 10 15 20 25 30

0 2.5 5 7.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

0

4

8

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 50 75 100 125 150 175 200 225 250

0 50 75 100 125 150 175 200

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 40-160.2

Speed 1760 rpm Speed 3600 rpm

65922 65924

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

34

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

0

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 20 30 40 50 60 70 80 90

0 20 30 40 50 60 70 80

0 4 6 8 10 12 14 16 18 20 22

0 1 2 3 4 5 6

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 4 6 8 10 12 14 16 18 20 22

0 1 2 3 4 5 6

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

0

4

8

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 50 75 100 125 150 175 200

0 50 75 100 125 150

0 10 15 20 25 30 35 40 45

0 2.5 5 7.5 10 12.5

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

H[m]

H[ft]

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 40-160.3

Speed 1760 rpm Speed 3600 rpm

65926 65928

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

35

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

0

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 25 50 75 100 125

0 25 50 75 100

0 5 10 15 20 25 30

0 2.5 5 7.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 5 10 15 20 25 30

0 2.5 5 7.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

2

6

10

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 50 75 100 125 150 175 200 225 250

0 50 75 100 125 150 175 200

0 10 15 20 25 30 35 40 45 50 55 60

0 2.5 5 7.5 10 12.5 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

11

10

09

08

07

06

05

04

03

02

01

Performance curveType 40-160.4

Speed 1760 rpm Speed 3600 rpm

65930 65932

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

36

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

0

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 50 75 100 125 150 175

0 25 50 75 100 125

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

.5

1

1.5

0

0

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

4

8

12

0

10

20

30

40

50

60

70

80

0

2

4

6

0

10

0 1

0 20 30 40 50 60 70 80

0 5 10 15 20

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 150 200 250 300 350

0 50 100 150 200 250

0 20 30 40 50 60 70 80

0 5 10 15 20

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 50-195.1

Speed 1760 rpm Speed 3600 rpm

65934 65936

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

37

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

0

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 50 75 100 125 150 175 200 225

0 50 75 100 125 150 175 200

0 10 15 20 25 30 35 40 45 50 55

0 2.5 5 7.5 10 12.5 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

1

2

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0

0 10 15 20 25 30 35 40 45 50 55

0 2.5 5 7.5 10 12.5 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

5

10

15

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 150 200 250 300 350 400 450

0 100 150 200 250 300 350 400

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 50-195.2

Speed 1760 rpm Speed 3600 rpm

65938 65940

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

38

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

330

0

75

150

225

300

375

450

525

600

675

750

825

900

975

1050

0 50 75 100 125 150 175

0 25 50 75 100 125

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0

0 10 15 20 25 30 35 40

0 2.5 5 7.5 10

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

5

15

25

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 100 150 200 250 300 350 400

0 100 150 200 250 300

0 20 30 40 50 60 70 80 90

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 50-195.3

Speed 1760 rpm Speed 3600 rpm

65942 65944

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

39

10

25

40

55

70

85

100

115

130

145

160

175

190

205

220

235

250

265

280

295

310

325

340

75

150

225

300

375

450

525

600

675

750

825

900

975

1050

0 50 75 100 125 150 175 200 225

0 50 75 100 125 150 175 200

0 10 15 20 25 30 35 40 45 50 55

0 2.5 5 7.5 10 12.5 15

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0

0 10 15 20 25 30 35 40 45 50 55

0 2.5 5 7.5 10 12.5 15

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

16

5

15

25

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 100 150 200 250 300 350 400 450

0 100 150 200 250 300 350 400

0 20 30 40 50 60 70 80 90 100 110

0 5 10 15 20 25 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

07

06

05

04

03

02

01

Performance curveType 50-195.4

Speed 1760 rpm Speed 3600 rpm

65946 65948

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

40

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

220

0

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 50 75 100 125 150 175 200 225 250 275 300

0 50 75 100 125 150 175 200 225 250

0 10 15 20 25 30 35 40 45 50 55 60 65 70

0 2.5 5 7.5 10 12.5 15 17.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 10 15 20 25 30 35 40 45 50 55 60 65 70

0 2.5 5 7.5 10 12.5 15 17.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

5

15

25

0

10

20

30

40

50

60

70

80

0

4

8

12

0

20

0 1 2

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

330

345

75

150

225

300

375

450

525

600

675

750

825

900

975

1050

1125

0 100 150 200 250 300 350 400 450 500 550 600 650

0 100 150 200 250 300 350 400 450 500 550

0 30 40 50 60 70 80 90 100 110 120 130 140 150

0 10 15 20 25 30 35 40

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 80-220.1

Speed 1760 rpm Speed 3600 rpm

65950 65952

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

41

7

17

27

37

47

57

67

77

87

97

107

117

127

137

147

157

167

177

187

197

207

217

227

50

100

150

200

250

300

350

400

450

500

550

600

650

700

0 100 150 200 250 300 350 400

0 100 150 200 250 300 350

0 20 30 40 50 60 70 80 90 100

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

2

4

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1

0 20 30 40 50 60 70 80 90 100

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

10

20

30

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 1 2 3

0 50 75 100 125 150 175 200

0 12.5 25 37.5 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

330

345

75

150

225

300

375

450

525

600

675

750

825

900

975

1050

1125

0 250 375 500 625 750 875

0 125 250 375 500 625

0 50 75 100 125 150 175 200

0 12.5 25 37.5 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 80-220.2

Speed 1760 rpm Speed 3600 rpm

65954 65956

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

42

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 150 200 250 300 350

0 50 100 150 200 250

0 20 30 40 50 60 70 80

0 5 10 15 20

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

3

6

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 20 30 40 50 60 70 80

0 5 10 15 20

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

10

30

50

0

10

20

30

40

50

60

70

80

0

3

6

9

0

15

0 1 2

0 25 50 75 100 125 150

0 12.5 25 37.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 125 250 375 500 625

0 125 250 375 500

0 25 50 75 100 125 150

0 12.5 25 37.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 80-220.3

Speed 1760 rpm Speed 3600 rpm

65958 65960

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

43

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

0 100 150 200 250 300 350 400

0 100 150 200 250 300 350

0 20 30 40 50 60 70 80 90 100

0 5 10 15 20 25

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

3

6

0

10

20

30

40

50

60

70

80

0

1

2

3

0

5

0 1

0 20 30 40 50 60 70 80 90 100

0 5 10 15 20 25

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

15

35

55

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 1 2 3

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 200 300 400 500 600 700 800 900

0 200 300 400 500 600 700 800

0 40 60 80 100 120 140 160 180 200 220

0 10 20 30 40 50 60

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 80-220.4

Speed 1760 rpm Speed 3600 rpm

65962 65964

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

44

0

15

30

45

60

75

90

105

120

135

150

165

180

195

210

225

240

255

270

285

300

315

330

0

75

150

225

300

375

450

525

600

675

750

825

900

975

1050

0 100 200 300 400 500 600

0 100 200 300 400 500

0 20 40 60 80 100 120 140

0 10 20 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

4

8

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 20 40 60 80 100 120 140

0 10 20 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

20

40

60

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 1 2 3 4

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 200 300 400 500 600 700 800 900 1000 1100 1200

0 200 300 400 500 600 700 800 900 1000

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 100-240.1

Speed 1760 rpm Speed 3600 rpm

65966 65968

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

45

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

0 200 300 400 500 600 700 800

0 200 300 400 500 600

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

4

7

10

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

30

50

70

10

20

30

40

50

60

70

80

90

0

6

12

18

0

30

0 2 3 4 5 6

0 100 150 200 250 300 350 400

0 25 50 75 100

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

0 500 750 1000 1250 1500 1750

0 250 500 750 1000 1250

0 100 150 200 250 300 350 400

0 25 50 75 100

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 100-240.2

Speed 1760 rpm Speed 3600 rpm

65970 65972

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

46

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 100 200 300 400 500 600

0 100 200 300 400 500

0 20 40 60 80 100 120 140

0 10 20 30

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

5

10

10

20

30

40

50

60

70

80

90

0

1

2

3

0

5

0 1 2

0 20 40 60 80 100 120 140

0 10 20 30

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

0

40

80

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 1 2 3 4

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 200 300 400 500 600 700 800 900 1000 1100 1200

0 200 300 400 500 600 700 800 900 1000

0 40 60 80 100 120 140 160 180 200 220 240 260 280

0 10 20 30 40 50 60 70

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 100-240.3

Speed 1760 rpm Speed 3600 rpm

65974 65976

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

47

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 200 300 400 500 600 700 800

0 200 300 400 500 600

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

4

8

12

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 1 2

0 40 60 80 100 120 140 160 180

0 10 20 30 40 50

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

13

12

11

10

09

08

07

06

05

04

03

02

01

14

30

70

110

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 2 3 4 5 6

0 100 150 200 250 300 350 400

0 25 50 75 100

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 500 750 1000 1250 1500 1750

0 250 500 750 1000 1250

0 100 150 200 250 300 350 400

0 25 50 75 100

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

05

04

03

02

01

Performance curveType 100-240.4

Speed 1760 rpm Speed 3600 rpm

65978 65980

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

48

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 250 375 500 625 750 875 1000

0 250 375 500 625 750 875

0 50 75 100 125 150 175 200 225 250

0 12.5 25 37.5 50 62.5

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

10

20

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 1 2 3 4

0 50 75 100 125 150 175 200 225 250

0 12.5 25 37.5 50 62.5

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 500 750 1000 1250 1500 1750 2000

0 500 750 1000 1250 1500 1750

0 100 150 200 250 300 350 400 450 500

0 25 50 75 100 125

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

50

100

150

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 2 3 4 5 6 7 8

0 100 150 200 250 300 350 400 450 500

0 25 50 75 100 125

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

04

03

02

01

Performance curveType 125-260.1

Speed 1760 rpm Speed 3600 rpm

65982 65984

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

49

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

420

440

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

1400

0 250 500 750 1000 1250 1500

0 250 500 750 1000 1250

0 50 100 150 200 250 300 350

0 25 50 75

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

15

30

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 1 2 3 4 5

0 50 100 150 200 250 300 350

0 25 50 75

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

0 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000

0 500 750 1000 1250 1500 1750 2000 2250 2500

0 100 150 200 250 300 350 400 450 500 550 600 650 700

0 25 50 75 100 125 150 175

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

100

150

200

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 2 3 4 5 6 7 8 9 10 11

0 100 150 200 250 300 350 400 450 500 550 600 650 700

0 25 50 75 100 125 150 175

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

04

03

02

01

Performance curveType 125-260.2

Speed 1760 rpm Speed 3600 rpm

65986 65988

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

50

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

0 500 750 1000 1250 1500 1750

0 250 500 750 1000 1250

0 100 150 200 250 300 350 400

0 25 50 75 100

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

20

40

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 2 3 4 5 6

0 100 150 200 250 300 350 400

0 25 50 75 100

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

550

575

600

625

650

375

500

625

750

875

1000

1125

1250

1375

1500

1625

1750

1875

2000

2125

0 1000 1500 2000 2500 3000 3500

0 500 1000 1500 2000 2500

0 200 300 400 500 600 700 800

0 50 100 150 200

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

200

400

10

20

30

40

50

60

70

80

90

0

10

20

30

0

50

0 3 4 5 6 7 8 9 10 11 12 13

0 200 300 400 500 600 700 800

0 50 100 150 200

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

03

02

01

Performance curveType 150-305.1

Speed 1760 rpm Speed 3600 rpm

65990 65992

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

51

0

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

0

150

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

0 500 750 1000 1250 1500 1750 2000 2250

0 500 750 1000 1250 1500 1750 2000

0 100 150 200 250 300 350 400 450 500 550

0 25 50 75 100 125 150

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

30

60

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 2 3 4 5 6 7 8 9

0 100 150 200 250 300 350 400 450 500 550

0 25 50 75 100 125 150

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

60

90

120

150

180

210

240

270

300

330

360

390

420

450

480

510

540

570

600

630

660

690

720

300

450

600

750

900

1050

1200

1350

1500

1650

1800

1950

2100

2250

0 1000 1500 2000 2500 3000 3500 4000 4500 5000

0 1000 1500 2000 2500 3000 3500 4000

0 200 300 400 500 600 700 800 900 1000 1100 1200

0 50 100 150 200 250 300

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

200

300

400

10

20

30

40

50

60

70

80

90

0

15

30

45

0

75

0 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

0 200 300 400 500 600 700 800 900 1000 1100 1200

0 50 100 150 200 250 300

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

03

02

01

Performance curveType 150-305.2

Speed 1760 rpm Speed 3600 rpm

65994 65996

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

52

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

0 500 750 1000 1250 1500 1750 2000

0 500 750 1000 1250 1500

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

5

15

25

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 2 3 4 5 6 7

0 100 150 200 250 300 350 400 450

0 25 50 75 100 125

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

0 500 750 1000 1250 1500 1750 2000 2250 2500 2750

0 500 750 1000 1250 1500 1750 2000 2250

0 100 150 200 250 300 350 400 450 500 550 600 650

0 25 50 75 100 125 150 175

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

0

40

80

10

20

30

40

50

60

70

80

90

0

4

8

12

0

20

0 2 3 4 5 6 7 8 9 10

0 100 150 200 250 300 350 400 450 500 550 600 650

0 25 50 75 100 125 150 175

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

07

06

05

04

03

02

01

Performance curveType 200-360.1

Speed 1150 rpm Speed 1760 rpm

65998 66000

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

53

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

360

380

400

0

100

200

300

400

500

600

700

800

900

1000

1100

1200

1300

0 500 750 1000 1250 1500 1750 2000 2250 2500

0 500 750 1000 1250 1500 1750 2000

0 100 150 200 250 300 350 400 450 500 550 600

0 25 50 75 100 125 150

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

10

20

30

10

20

30

40

50

60

70

80

90

0

2

4

6

0

10

0 2 3 4 5 6 7 8 9 10

0 100 150 200 250 300 350 400 450 500 550 600

0 25 50 75 100 125 150

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

12

11

10

09

08

07

06

05

04

03

02

01

0

25

50

75

100

125

150

175

200

225

250

275

300

325

350

375

400

425

450

475

500

525

0

125

250

375

500

625

750

875

1000

1125

1250

1375

1500

1625

0 1000 1500 2000 2500 3000 3500 4000

0 1000 1500 2000 2500 3000

0 200 300 400 500 600 700 800 900

0 50 100 150 200 250

H[m]

H[ft]

U.S.gpm

Imp.g.p.m.

Q m /h

Q l/s

3

40

80

120

10

20

30

40

50

60

70

80

90

0

5

10

15

0

25

0 3 4 5 6 7 8 9 10 11 12 13 14

0 200 300 400 500 600 700 800 900

0 50 100 150 200 250

P[kW]

ETA[%]

NPSH

[m] [ft]

Q m /h

Q l/s

Q m /min

3

3

07

06

05

04

03

02

01

Performance curveType 200-360.2

Speed 1150 rpm Speed 1760 rpm

66002 66004

Notes to performance curves � Curves valid according to DIN EN ISO 9906/2B. � Power data refers to clean water, density 1 kg/dm³, viscosity 1 mm²/s. � All duty points between the individual stage characteristics can be achieved by adapting the impeller diameters.

60Hz

54

For your notes

ANDRITZ Ritz GmbHGüglingstraße 5073529 Schwäbisch Gmünd, GermanyPhone: +49 (0)7171 609 0Fax: +49 (0)7171 609 [email protected]

All data, information, statements, photographs and graphic illustrations made in this leaflet are without any obligation and raise no liabilities to or form part of any sales contracts of Andritz AG or any affiliates for equipment and/or systems referred to herein. © Andritz AG 2016. All rights reserved. No part of this copyrighted work may be reproduced, modified or distributed in any form or by any means, or stored in any database or retrieval system, without the prior written permission of Andritz AG or its affiliates. Any such unauthorized use for any purpose is a violation of the relevant copyright laws. Andritz AG, Stattegger Strasse 18, 8045 Graz, Austria.

Close to our customers

www.andritz.com/pumps