High Fusion Performance in Super H-Mode Experiments on Alcator C-Mod and DIII-D P.B. Snyder1, J.W. Hughes2, T.H. Osborne1, C. Paz-Soldan1, W. Solomon1, D. Eldon1, T. Evans1, T. Golfinopoulous2, R.J. Groebner1, A. Hubbard2, A. Jarvinen3, M. Knolker4, B. LaBombard2, F. Laggner4, A. Leonard1, O. Meneghini1, S. Mordijck5, T. Petrie1, S. Scott4, H.Q. Wang6, J.G. Watkins7, H.R. Wilson8, Y.B. Zhu9
Presented at 2018 IAEA Fusion Energy Conference Ahmedabad, Gujarat, India October 22–27, 2018
1 General Atomics 2 MIT Plasma Science and Fusion Center 3 Lawrence Livermore National Lab 4 Princeton University / PPPL 5 College of William and Mary 6 Oak Ridge Associated Universities
7 Sandia National Laboratory 8 York Plasma Institute, University of York, York UK 9 University of California-Irvine, Irvine CA
P.B. Snyder/IAEA/October 2018
2
Super H-Mode Experiments on Alcator C-Mod and DIII-D Achieve High Fusion Performance, Record Pedestal Pressure
• Super H-mode (SH) predicted in strongly shaped plasmas: high pped, increases with ne [Snyder NF15]
• Record pedestal pressures (~80 kPa) achieved in C-Mod SH experiments [Hughes NF18] • Successful tests of EPED model up to ~90% of predicted ITER pped
• Record DIII-D fusion gain (QDT,eq~ 0.54). QDT,eq/IaB and QDT,eq/(RB)2 highest reported on any tokamak
• High performance sustained w/ 3D magnetic perturbations to control ne and impurity accumulation • Predicted to enable high performance on ITER, and be compatible with high separatrix density for
divertor solutions
3
EPED Model Predicts a High Pedestal “Super H-Mode” Solution
• EPED (Snyder NF11) normally predicts a single pedestal solution – Intersection of calculated peeling-ballooning (PB) and KBM criticality
– Predicted using sets of realistic model equilibria w/ self-consistent bootstrap current
• At strong shaping, fixed input parameters (including density), PB mode can go from stable to unstable (pressure driven) and back to stable again with increasing pressure and current: multiple roots for two “equations”, PB and KBM
0.00 0.02 0.04 0.06 0.080
5
10
15
20
25
30
35
Pedestal Width ( N)
Pedesta
l H
eig
ht (p
pe
d, kP
a)
Illustration of EPED1 Model, Multiple Roots
Peeling-Ballooning
KBM
EPED1 Prediction
S
SU
U
P.B. Snyder/IAEA/October 2018
4
EPED Model Predicts a High Pedestal “Super H Mode” Solution
• Expect only lowest solution to be accessible for these parameters. However, can move in third dimension (eg density) to access higher roots (Super H)
• SH predicted by theory [Snyder12,15], discovered and explored in counter Ip campaigns on DIII-D [Solomon14, Snyder15, Garofalo15, Solomon16]
2016 C-Mod: L-I-H transition to explore Super H regime access 2017-18: DIII-D: co-Ip SH expts explore performance and core-edge
0.00 0.02 0.04 0.06 0.080
5
10
15
20
25
30
35
Pedestal Width ( N)
Pedesta
l H
eig
ht (p
pe
d, kP
a)
Illustration of EPED1 Model, Multiple Roots
Peeling-Ballooning
KBM
EPED1 Prediction
S
SU
U
1 2 3 4 5 6 7 8 9 100
5
10
15
20
25
Pedestal Density (1019 m-3)
Pede
stal H
eight
(kPa)
EPED Predicted Pedestal Height vs Density
Super H-ModeH-ModeNear Super H
P.B. Snyder/IAEA/October 2018
5
High peak performance in Super H-Mode experiments
P.B. Snyder/IAEA/October 2018
6
Pedestal Density [ne,ped(Zeff /2)1/2 ,1019 m-3 ]
Pede
stal
Pre
ssur
e (k
Pa)
Very High Super H Mode Pressure Predicted for C-Mod
• Alcator C-Mod is a compact, high field device (here Bt~5.3T), capable of high δ – After discovery of Super H-Mode on DIII-D, predictions were made for C-Mod (right)
• Test SH theory at high Bt & Bp, zero injected torque (RF), high Z metal wall – Following the right parametric trajectory should enable very high pressure
• Need to reach densities much lower than typical for C-Mod H-mode to access Super H • Challenging to do on a high-Z metal wall device like C-Mod
?
P.B. Snyder/IAEA/October 2018
7
Access to Super H Mode on C-Mod Achieved via L-I-H Transition
• Transitioning first to I-mode, then to H-mode leads to a low ne, low impurity H-mode (left) • As pedestal approaches predicted kink/peeling limit, low n mode observed (center) • Discharges at 1MA, 5.4T reach SH regime, pped~70 kPa (right)
Hughes et al, NF 58 112003 (2018) Pedestal Density [ne,ped(Zeff /2)1/2 ,1019 m-3 ]
Pede
stal
Pre
ssur
e (k
Pa)
680ms720ms
760ms790ms
C-Mod 1160922020, 0.8MA
Pede
stal
Pre
ssur
e (k
Pa)
Pedestal Density [ne,ped(Zeff /2)1/2 ,1019 m-3 ]
750ms
770ms
790ms810ms
830ms
850ms870ms
930ms
C-Mod 1160922032, 1MA
P.B. Snyder/IAEA/October 2018
8
100 101 102100
101
102
EPED Predicted Pedestal Height (kPa)
Mea
sure
d Pe
dest
al H
eigh
t (kP
a) C-Mod (3, SH expt)C-Mod (10, ELMing H-mode)DIII-D (124)JET (137)JT-60U (16)Compass (23)AUG (13)ITER
0 2 4 6 8 10 12 14 16 18 20 220
102030405060708090
100110120
Pedestal Density [ne,ped(Zeff/2)1/2,1019m-3]
Pede
stal
Pre
ssur
e (k
Pa)
EPED Predictions 1.4MA (based on 1160930042)
H-ModeNear Super HSuper H-ModeMeasured (C-Mod)
Super H-Mode Experiments on C-Mod Yield ITER-like pped
• Super H-Mode expt at 1.4MA achieved record 81 kPa pedestal pressure on last day of Alcator C-Mod operations, ITER-like pressure at ITER-like field [Hughes NF 2018] – EPED model successfully tested over 2 orders of magnitude in pressure on 6 tokamaks
• No indication of significant variation of model accuracy with ρ* or pped
P.B. Snyder/IAEA/October 2018
9
• High pedestal pressure enables good confinement, high global MHD limits – C-Mod: Bt=5.3-5.8T, Ip=0.8-1.4MA, a=0.19m, R=0.67m, δ~0.5
• <p> ~ 100-170 kPa, pped ~ 50 - 80 kPa – DIII-D: Bt=2.1-2.2T, Ip=1.6-2.0MA, a=0.6m, R=1.67m, δ~0.5-0.7
• <p> ~ 70 – 110 kPa, pped ~ 20 – 32 kPa, Ti,0 ~ 14 -18 keV
Broad Profiles and High Pressure Obtained in Both C-Mod and DIII-D
Electron Density (10 m )
0 2 4 6 8
Electron Temperature (keV)
02468
Ion Temperature (keV)
0.2 0.4 0.6 0.8 1.005
1015
DIII-D 177007 @ 2190ms
0Normalized Radius (ψ )
19 -3
N
177007.2190.00Electron Density (10 m )
Electron Temperature (keV)
Pressure (kPa)
19 -3
(Total)
(Electron)
C-Mod 1160930042 @ 900ms
Normalized Radius (ψ )N
0.2 0.4 0.6 0.8 1.000
100200300
400
510152025
0
0
2
4
6
8
P.B. Snyder/IAEA/October 2018
10
• Deep access into Super-H regime, good agreement with EPED predictions – Bt=2.1T, Ip=1.6-2.0MA, a=0.6m, δ~0.5-0.7 – pped~30kPa, W~2 - 3.2 MJ (highest in present DIII-D config.) at modest Pnbi ~ 8-12 MW – Peak τ~0.4-0.7s, H98~2.2-2.9, <p>τE ~ 30-67 kPa s, nTτ ~ 4 - 8 1020 keV m-3 s
Very High Pedestal Pressure, Stored Energy, and Confinement Time in Recent co-Ip Super H-Mode Experiments on DIII-D
3 4 5 6 7 8 9 10 11 120
5
10
15
20
25
30
35
Pedestal Density [ne,ped(Zeff/2)1/2,1019m-3]
Pede
stal
Pre
ssur
e [2
*pe,
ped,
kPa]
Access to High Performance Super H-Mode Regime on DIII-D
H-ModeNear Super HSuper H
t=2.1s
t=2.2st=2.3s t=2.4s
P.B. Snyder/IAEA/October 2018
11
• DD neutron rates up to 1.85 1016/s – ~2/3 thermal, Pfus,DD ~ 22 kW, Pfus,DT,eq ~ 4.8 MW (at Pnbi ~ 9 MW)
High Pedestal Pressure and Ti Enable High Peak Fusion Performance on DIII-D
P.B. Snyder/IAEA/October 2018
1.95 2.10 2.25 2.400.0
0.4
0.8
1.2
1.6
2.0174809
Total(TRANSP)
Measured
Thermal(TRANSP)
Beam-Target (TRANSP)
Beam-Beam (TRANSP)
Time (s)
Neu
tron
Rat
e (1
0
/s)
16
12
• Equivalent QDT,eq = Pfus,DTeq/Pnbi ~ 0.54. Q*DT,eq=Pfus,DTeq/(Pnbi-dW/dt) ~ 1
– Previous DIII-D record Q = 0.32, Lazarus96 in negative central shear discharges with 2.2MA, 22m3
– Achieved at modest B = 2.17T, Ip=2MA, V=20 m3. DTeq Fusion power density ~0.2 MW/m3
High Pedestal Pressure and Ti Enable High Peak Fusion Performance on DIII-D, Record Fusion Gain
Appears to be highest QDT,eq and <p>τ on any medium size (R<2m) tokamak, and highest QDT,eq/IaB or QDT,eq/R2B2 on any MFE device
0.54
0.32
P.B. Snyder/IAEA/October 2018
13
Sustainment and Core-Edge Compatibility of
Super H-Mode Regime
14
0
1
2
3
0
1
0
1
2
2000 2500 3000 3500 4000 4500
171322
Time (ms)
3
2
• High performance condition sustained by applying 3D magnetic perturbation – Controls density and impurity
accumulation – Feedback control of pedestal or
average density demonstrated – Sustained W~1.9MJ, QDT,eq~ 0.15, τ~0.2s, H98~1.6, βN ~ 2.9
– ~2s sustainment (hardware limited)
Super H-Mode Sustained Using 3D Magnetic Perturbations to Control Density and Impurity Accumulation
High sustained βN
Excellent confinementH98~1.6-2.5, τE~0.2-0.6s
Highest WMHD (~2.3-3.2MJ) since 2002Sustained WMHD~ 2 MJ
i-coil enables stationarydensity, pressure
WMHD
(MJ)
βN
H98
P.B. Snyder/IAEA/October 2018
15
• Super H (J-limited) solution predicted not to show degradation of pedestal pressure w/ ne,sep – P-limited solution degrades with increasing ne,ped
and ne,sep (eg high gas puff in JET ILW)
• Scan D2 gas rate, and introduce radiative impurities (N2) into the Div/SOL to test predictions on DIII-D – Use 3D magnetic perturbations (i-coil) to control particle and
impurity accumulation in core
– Use i-coil feedback to maintain ~constant density in pedestal & core as separatrix, divertor and SOL density are increased
• Test EPED predictions of sensitivity of pedestal to separatrix conditions
Connecting a High Performance Super H Pedestal & Core to a High Density, Radiative Divertor & SOL
3 4 5 6 7 8 9 10 11 120
5
10
15
20
25
30
35
Pedestal Density [ne,ped(Zeff/2)1/2,1019m-3]
Pede
stal
Pre
ssur
e [k
Pa]
Separatrix density half of pedestal (Bt=2.17T, Ip=1.6MA, tri=0.56)
EPED (H-Mode)EPED (Near Super H-Mode)EPED (Super H-Mode)
J-limited
P-limited
P.B. Snyder/IAEA/October 2018
16
• D2 gas scan in Super H mode experiment at Ip=2MA, Bt=2.1T. Gas rate varied ~30x – Pedestal pressure and τE remain ~fixed, high – i-coil feedback control of ne,ped ~ 7-8 1019 m-3
successful up to~110 torrL/s of D2 gas – Separatrix density rises from ~2.5 – 4 1019 m-3
– Strike point density rises from ~2.5 – 7 1019 m-3
D2 gas Scan Increases Separatrix and Divertor Density while Pedestal Pressure and Confinement Remain High
Both pedestal and separatrix density reach ITER values while maintaining high confinement and pped
P.B. Snyder/IAEA/October 2018
Super H-mode compatible with both high fusion performance and high separatrix density for
divertor solutions.
17
• Significant cooling with ~5MW of divertor radiated power using feedback on N2
– Peak Te near strike point drops more than 3x – Pedestal pressure and confinement remain
~constant – Future experiments needed to explore full
detachment and impact of closed divertor
N2 Injection Effective for Cooling Divertor while Maintaining High Performance Core & Pedestal
Outer divertor
0102030405060
0.99 1.00 1.01 1.02 1.03 1.04ψn,out
0
2
4
6
8
10
177018,2300−2600ms177018,3300−3600ms
T (eV)
n (10 m )
e
e19 -3
P.B. Snyder/IAEA/October 2018
18
Predictions for ITER, Implications for Compact, High Performance Fusion
19
Super H/NSH Regime Access is Predicted for ITER: DIII-D has Achieved Needed βN,ped, ne,sep, ne,ped Consistently
Open issue: Physics of the Greenwald density limit which constrains degree of Super H
access and predicted performance for ITER and DEMO concepts
• Core-pedestal simulations find ITER high performance (Q>10) at high ne [Meneghini16]
• DIII-D SH experiments reproduce many characteristics of the predicted ITER regime, including βN,ped~0.8, ne,sep~3-4, ne,ped~7-10. C-Mod produces pped~80 kPa
– Potential for substantial improvements in ITER performance, consistent with ne,sep
0 2 4 6 8 10 12 14 16 180
20
40
60
80
100
120
140
160
Pedestal Density * (Zeff/2)1/2 (1019 m-3)
Pede
stal
Pre
ssur
e (k
Pa)
EPED Predicted Pedestal Height vs Density for ITER Baseline
H-ModeNear Super HSuper H
P.B. Snyder/IAEA/October 2018
20
Super H and Near Super H Operation Enables Very High Fusion Performance per IpaBt
• Simple metric of fusion performance (Q or <p>W/P) per IpaBt – Colored points are observations (<p> > 50 kPa), red points are SH/NSH experiments – High Q/IaB enables ITER success, and compact, cost attractive pilot plant
Open issues: Challenges for Super H-mode operation include
sustainment, impurity control, and ELM control.
For JET and ITER, compatibility of strong shaping and nearby
metal walls
P.B. Snyder/IAEA/October 2018
21
• Theoretical prediction of Super H Mode has guided successful expts on C-Mod and DIII-D – Entering new era where theory can enable predictable, higher MFE performance
• Record pedestal pressures (~80 kPa) achieved in C-Mod SH experiments [Hughes NF18]
– Successful tests of EPED model up to ~90% of predicted ITER pped
• Record DIII-D fusion gain (QDT,eq~ 0.54, Q*DT,eq~ 1). QDT,eq/IaB ~ 0.21 and QDT,eq/(RB)2 ~ 0.04
• Projects (theoretically & empirically) to excellent ITER performance, compact attractive pilot plant
• High performance sustained w/ 3D magnetic perturbations to control ne and impurity accumulation (DIII-D: W~1.9MJ, QDT,eq~ 0.15, τ~0.2s, H98~1.6, βN ~ 2.9)
• High performance maintained with strong D2 gas puffing and N2 injection • Separatrix density reaches ITER values, divertor T reduced by ~3x
High Fusion Performance and Promising Core/Edge Solutions Developed via Super H Theory & Experiment
Super H-mode compatible with both high fusion performance and high separatrix density for divertor solutions. Projects to excellent
ITER performance and compact, attractive pilot plant
P.B. Snyder/IAEA/October 2018
22
Extra Slides
23
C-Mod H-modes triggered using a sweep in magnetic balance leads to low-ne high-T pedestal evolution
23
B×∇B is toward upper divertor
LSN DN
Short I-mode
Phase
H-formation
ICRF on
Te,95
24
• Significant cooling going from ~5MW of divertor radiated power using feedback on N2
• Peak Te near strike point drops more than 3x, pedestal pressure and confinement remain ~constant
N2 Injection Effective for Cooling Divertor while Maintaining High Performance Core/Pedestal
N2 + D2
Time(s)Time(s)
25
Similar Level of EPED Accuracy with Metal or Carbon Wall
• Metal: average error=1.46 (14%), correl=0.90, σ=0.19
• Carbon: average error=1.88 (18%), correl=0.85, σ=0.22
• No indication of strong effect of wall material on EPED accuracy – JET ILW has lower impurity levels,
different operational limits than JET C
– Studying impact of impurities and gas puffing
0 100 200 3000
10
20
30
40
Case Number (Ordered by Shot #)
Pede
stal P
ressu
re (kP
a)
Metal Walls, EPED1 Comparison (10 C-Mod, 335 JET ILW)
EPED1 PredictionMeasured Ptot,pedMeasured 2ne,pedTe,ped
0 100 200 3000
10
20
30
40
Case Number (Ordered by Shot #)
Pede
stal P
ressu
re (kP
a)
Carbon Walls, EPED1 Comparison (225 DIIi-D, 137 JET CFC)
EPED1 PredictionMeasured Ptot,pedMeasured 2ne,pedTe,ped
P.B. Snyder/IAEA/October 2018