High Definition Commissioning
NETA PowerTest Spotlight Presentation March 15, 2016
2
Meeting Agenda
• Introduction to ComRent solutions
• Industries ComRent Supports
• Value of Load Bank Testing
• Trends in Precision Commissioning
• Takeaway
3
ComRent chosen when Time, Reliability and Performance matter most
1. 19 years of experience successfully commissioning and testing data centers and utility projects on time and on budget
2. Turnkey solution from product proficiency, technical knowledge to project management expertise
3. Largest fleet of load banks in the North America, capable of testing jobs from 1kW to 100MW
4. Efficient logistics solutions to get product to your location, faster
TEST BETTER WITH COMRENT
4
Experience Matters A successful track record spanning 19 years
1997 Company founded. Entered load bank rental market
2003 Entered medium voltage market
2005 Leader in data center commissioning
2009 • Performed 1st
substation test • Started Canada
operations – Montreal, Mississauga, Edmonton
2011 Entered Latin American Market
2013 Performed test at 220kV
2015 • Performed 62MVA
resistive/reactive test
• Commissioned a 50MW project
5
Most Trusted Load Bank Solutions Provider
Safety Reliable Fleet Available Product
Performance at all power levels
3,210 .87
2015 EMR safety value
24
Average availability (hrs.)
Product uptime
40,000
Completed systems from 1kW to 50 MW
99%
Fleet size (units)
6
UNMATCHED SERVICES & PRODUCTS
7
High Value Service Offering End-to-end attention to detail
PROJECT
SUPPORT
24/7 Support Available for tech
support
Power Quality Report With rental of Cx monitor, quickly run reports
Cable Rollout/Rollup Save time and avoid errors during setup/teardown
Onsite training Introduction to load banks. Offer onsite operation
Project Management Site survey, cable layout plan, single line diagram
CABLING
TRAINING
REPORTING
8
The nations largest fleet with the most reliable equipment
15 global locations, 3,210 units, 145 kilometers of cable and new products launching in 2016
9
Resistive/Reactive Load Banks
RESISITVE LOAD BANKS
• Test generator capacity and electrical circuits for power quality and capacity
• 4.5 to 2500kW per unit @ 120, 240, 480, 600 VAC
• Up to 5MW @ 13.8kV or 4160V
REACTIVE LOAD BANKS
• Mimic motor load, electromagnetic devices as well as resistive loads by setting a specific power factor (PF)
• Provides 0.8 pf companion to Resistive Load Banks and for MV inductive testing
10
Additional Products
• Up to 1000 V-DC for battery and UPS systems,
• Variable Amperage settings up to 600 A
• Multi-tap configurations: wye-wye or delta-wye
• 50/60Hz capable step down to 480/600VAC
Specialty
• Liquid cooled high-power density load bank
• Non-Linear Load Bank • Advanced Control and
Communication
DC Load Banks Transformers
11
Accessories
CX MONITOR POWER QUALITY MONITOR
• Advanced PQ monitoring and reporting • Gathers voltage and current data
required commissioning tests • Capture harmonic and DC voltage data
for one hundred (100) locations!
• Provides a tangible written report
DAYCOR CORONA CAMERA CABLE
35kV cable • Only company to supply over 35KV cable in
lengths greater than 30m up to 186m.
Camlock Cable • Premium 90°C insulated 50’ cable up to 405
amps for UPS, CATV, telecom, & power utility
Voltloc Cable • Designed for Medium Voltage power systems • 200 Amp load break elbow, 200/600 Amp dead
break elbow
v
CABLE
12
Industries ComRent Supports
13
Data Center Commissioning
Validate Power and Cooling Systems
• Wi-Fi IP addressable for multi-unit control
• Water cooled load banks for cooling validation
• PDU, CRAC, ATS, UPS
Test Power Quality and DC Systems
• UPS input and output checks
• Up to 100 Wi-Fi probes/unit, multi-unit capable
Integrated System Testing
• Rack-mount and Whole-room testing
14
Substation Commissioning
• Substations up to 230kV can be commissioned quickly and safely
• Tests all critical components in an integrated system test: o Protective Relays o Current transformers o Voltage transformers o Breaker equipment o Control and SCADA systems
• Turnkey support streamlines planning, logistics, and execution
15
Utility Solar Commissioning
• Most common types of inverters are: 600kW-900kW o Products 2-2.2MW being
released late 2016 • Anti Islanding protection requirements
o Required testing completed with R/L/C load bank
o Required to satisfy UL1741 and IEEE 1547.1 test requirements
• Communication/Control system- sleep/wake modes, GPS tracking
• Manufacturer type testing (European and Asian importing manufacturers only)
16
Wind Commissioning Solutions
• Wind Farm Commissioning tests can be performed to maintain project schedule, even if the grid connection is not available.
• Diesel Generators and load banks create a simulated grid connection/substation for each collector
• Capable of simulating startup and power generation of the turbines for each collection point in a wind farm
17
VALUE OF LOAD TESTING
18
Value of load testing through the equipment lifecycle
Commissioning
Maintenance
System Updates
• Proves equipment is properly integrated
• Tests all critical components
• Validates operation and efficiency
• Critical for complex systems with multiple components, devices, firmware, and software
• Verifies corrective action or system design change
• Valuable for re-commissioning
19
Value of Load Testing During Integrated System Test
Save time • Maintain schedule and coordination with scheduled shutdown • Engineering resources scheduled to a fixed date prior to construction • Allows for periodic maintenance testing of protection and
communication system
Lower Cost • Minimize unplanned overtime due to weather or load conditions • Embedded contingency reduces risk insurance cost
Increase Productivity
• Engineering focused on defining deliverables, not work-arounds • Effectively schedule craft labor resources • Minimize impact of weather on project schedule
Reduce Risk • Reduced liability from accurately simulating load (Resistive, reactive and step functions)
• Eliminate risk of using customer load • Regular maintenance testing improves availability of system
CUSTOMER BENEFITS
1
2
3
4
20
Precision Commissioning
21
Precision Commissioning
• Integrated System Test
ComRent Confidential
Load Testing Performed
Rack-Mounted Load Banks
Provide Best Resolution
22
Precision Commissioning
Integrated System Test Primary and Backup power sources
UPS, Generators, Switchgear, alternative power sources
Utility or Facility interconnections
Substation or switchyards
Transformers
IT space “white floor” equipment or critical process equipment
Racks, PDUs, Busways, Breakers
Critical support systems
Chillers and cooling systems
Security, fire suppression
BMS and DCIM settings and calibration
23
Precision Commissioning
Precision Commissioning Benefits
Testing system capacity prior to load
Accurate simulation of electrical load and thermal distribution
Optimizing Cooling to reduce energy use
Ensure LEED compliance, proper equipment sizing
Test power system including “outside the fence” connections based on the OPR
ComRent Confidential
24
Precision Commissioning
Rack-mounted load banks for precision commissioning Closely match that of the transient load of a
2U to 5U standard market server
Accurate simulation of IT equipment Hot/Cold space separation effectiveness Best way to test entire power supply system
• New Rack Mount System Being Developed Remote Capable Better Airflow Management Larger Capacity
ComRent Confidential
25
Precision Commissioning
ComRent’s New Precision Commissioning System • Rack Mount System
– Wide range of capacity
– Precise load steps
– Airflow adjustability
– Less weight per module and per KW of load
– Easy Mount System
– Remotes
ComRent Confidential
?
26
Best Practices
Facility Optimization
Advanced controls allow operator to control entire load bank string remotely
Allows for more sophisticated modeling of electrical load steps and dynamic thermal load
The Water Cooled offering EXLS 250 and LBW 500. Auto-flow control that allows the user
to program the desired Delta T and the unit will control the flow to provide the desired value.
ComRent Confidential
27
Takeaways
• Integrated system testing provides the best results for reliability and availability of an electrical system
• Precision commissioning is an area of high innovation
– Provides the opportunity to optimize a critical facility
28