CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

PAGE

Hellan Strainer Benefits 1

Quality Assurance and Product Testing 2

Codes and Standards Compliance 3

Typical Applications 4-5

Unique Strainer Operation 6-7

Strainer Types 8-10

Selecting a Strainer 11-12

Screen Options 11 & 13

Materials and Flange Options 13

Component Material 14-16

Standard Flow Rates and Pressure Ratings 17

Automatic Operation Options 18-19

External Scraper Adjustment 20

Pressure Switch and Three Way Ball Valve 21

Flow Rate vs Pressure Drop 22

Dimensional Information 23-53

Typical Pressure Drop vs Flow Rate Curves 54-79

Model Number Specification 80-81

Samples of Standard Specification 82

Page 3: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1

BENEFITS OF THE HELLAN STRAINER

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

REMOVE SOLIDS WITHOUT STOPPING THE FLOW

Instead of trapping solids in a basket which must then beremoved for frequent clean-outs, the Hellan Strainer removessolids from the fluid flow without stopping the flow or disas-sembling the strainer. A simple turn of the hand wheel (oractuation of the screen motor in automatic units) rotates thescreen against a scraper bar. Debris moves to a sump areawhere it is removed by periodic flushing.

LOW OPERATING COSTS

Removing solids from the screen takes about thirty seconds,compared to one or two hours for a basket strainer. Laborcosts can be completely eliminated with our automatic self-cleaning strainer.

SAFETY FOR EMPLOYEE PERSONNEL

The Hellan Strainer closed system protects personnel from contact with strained debris that may include contaminants orhazardous materials.

HIGH QUALITY CONSTRUCTION

Hellan Strainers are designed and built to ANSI/ASQCStandard Q94-1987. Each strainer is proof pressure tested to150% MAWP, per ASME standards, before shipment. QualityAssurance and manufacturing systems are registered for compliance with ISO-9001 International Standard.

MEET OR EXCEED MAJOR CE/PED, AND INTERNATIONAL STANDARDS

Hellan Strainers are available in models that comply withmajor U.S. industrial codes and standards, including ASME,the American Bureau of Shipping, Lloyd’s Register, CE/PEDand the Fluid Control Institute. Select models are listed withUnderwriters Laboratories. Models are also available in compliance with major international standards, includingD.I.N., I.E.C. and Cenelec specifications.

MATERIAL OF CONSTRUCTION FOR A VARIETYOF APPLICATIONS

Hellan Strainer bodies are available in cast iron, cast steel, cast stainless steel, bronze and custom materials such as SuperDuplex to meet the demands of a wide range of applications.

LOW MAINTENANCE COSTS

While there is no routine disassembly needed with a HellanStrainer, all of the internal components can be changed without any special tools. Servicing or parts replacement istherefore very inexpensive.

LOW INSTALLATION COSTS

A Hellan Strainer weighs about half as much as comparableconventional basket-type strainers and requires about 60% of the space. It may be mounted in-pipeline, in a vertical orhorizontal position. No special foundation is needed andinstallation is simple and less costly.

MANUAL OR AUTOMATIC OPERATION

Hellan Strainers are available in manual or automatic models.A full array of controls is available for remote, automatedoperation of automatic models. Manual models can beupgraded to automatic operation in the field without disruption of the fluid handling system.

LOW CAPITAL INVESTMENT

Hellan Strainers are competitively priced.

Page 4: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

QUALITY ASSURANCE AND TESTING TESTING

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

2

Hellan Strainers are designed and manufactured under a stringent Tool Quality Management Program. This TQM pro-gram and a continuous improvement policy keep our qualitystandards and procedures among the highest in the industry.Designed to ISO 9001, our quality program directs all aspects ofour business, including procurement, design, manufacturing,inspection and testing.

Every Hellan Strainer is designed and built to ANSI/ASQCStandard Q94-1997. Prior to shipment, each strainer is proofpressure tested to 150% MAWP, per ASME standards.

Our commitment to quality and the unique operating featuresof our strainer design assure our customers that HellanStrainers will provide consistent performance in even the mostchallenging applications.

Page 5: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

3

STANDARDS, CERTIFICATION AND PATENTS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Hellan Strainers are available in models that comply withmajor U.S. and international standards, including those ofthe following organizations:

American Bureau of ShippingAll Hellan Strainers appearing in this cataloghave been certified for service in fuel oil, lube oil, fresh water and sea water service bythe American Bureau of Shipping. ABS hasrated Hellan Strainers for 150 PSI (10.34 bars) MAWP to 740 PSI (51.02 bars)MAWP, depending on flange class, con -struction material and temperature of theprocess fluid.

American Society of Mechanical Engineers (ASME)Hellan Strainers are designed and manufac-tured in accordance with ASME Boiler andPressure Vessel Code, Section VIII, Division 1. All strainers are proof pressuretested at 150% of their recommended maximum allowable operating pressure.

Fluid Control Institute (FCI)Hellan Strainers are manu-factured in accordance withFCI standard 78-1.

National Fire Sprinkler Association, Inc.Cleveland Gear is a member of the NationalFire Sprinkler Association, Inc.

Underwriters LaboratoriesNon-automatic Hellan Strainers constructedof cast iron, cast steel or cast stainless steelin pipe sizes from 2" through 14" withscreen perforations of 3/32", 1/8" or 3/16"are listed with Underwriters Laboratories(Re-exami nation service) and are UL listedunder Strainers, Pipe Line (HLCV), File EX1708(N), “Fire Main Pipe Strainer.”

CE CertifiedNon automatic strainers cast in steel or stain-less steel pipe sizes 4"-12" can be CE certifiedto Pressure Equipment Directive PED97/23/EC if requested.

ISO-9001Quality systems certified by Det NorskeVeritas to ISO-9001 International Standard.Certificate No. QSC-4386.

Lloyd’s RegisterHellen Strainers are Type Approved byLloyd’s Register and have met their requirements for use in fresh and salt watersystems (including fire main), fuel oil systems and lubricating oil systems.Certificate No. 01/60001

International StandardsHellan Strainers are available in models that comply with most international standards, including D.I.N., I.E.C. andCenelec specifications.

Patent ProtectionHellan strainers are protected by several U.S. patents. Design applications on file for new patent protection.

R

Page 6: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

APPLICATIONS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

4

MARINE

Hellan Strainers are used on U.S. Navy ships in sea water cooling of electronic equipment (i.e., sonar, radar, close inweapon systems, etc.), lube oil, firemain systems, and fuel filtration.

PETROLEUM

Hellan Strainers are used on offshore rigs around the world infire protection and filtration systems.

PETROCHEMICAL

Hellan Strainers protect plant equipment (i.e., condensers,spray nozzles, heat exchangers, pumps, etc.) strain coolingtower water, remove polyethylene fines from process water and are used in deluge fire protection systems.

Page 7: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

5

APPLICATIONS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

FIRE PROTECTION

Hellan Strainers are U.L. approved for spray nozzle protectionin all types of fire protection systems.

WASTE WATER TREATMENT

Hellan Strainers are used in belt filter presses for protection ofspray nozzles and in secondary effluent systems for protectionof chlorinators, seal water, plant service and foam control.

ETHANOL PLANT

Hellan Strainers are used to protect plate and frame heatexchangers downstream of the slurry tank. Used to capturecorn slurry from caustic solution during cleaning of the slurry tank.

POWER UTILITY PLANTS (FOSSIL, HYDRO & NUCLEAR)Hellan Strainers remove zebra mussels, sand, grit, small fish,etc., from lakes and rivers for protection of plant equipment.Strains water for turbine bearings.

IRON AND STEEL FACILITIES

Hellan Strainers are used in recirculating water, descaling water and cooling water for hot strip and plate mills, blast furnaces, open hearths and continuous casting mills.

IRRIGATION SYSTEMS

Hellan strainers are used in irrigation systems, including golfcourses, to protect spray nozzles by removing debris fromlakes, rivers and ponds.

Page 8: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

UNIQUE OPERATING FEATURES

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

6

THE HELLAN STRAINER DESIGN PROVIDES SOLIDSREMOVAL WITHOUT INTERRUPTING THE FLUID FLOW

Instead of trapping solids in a basket which then must beremoved for frequent clean-outs, the Hellan Strainer removesthe solids from fluid without stopping the flow or disassembling the strainer. The sequence of operation is illustrated below.

❶ Fluid passes into the strainer and through a screen.

❷ A deflection rib protects the screen from large objects.

❸ The screened fluid flows out of the strainer and into service.

❹ Rotating the screen, by either handwheel or motor,moves the outer screen surface against a scraper bar. The scraper bar removes collected debris from thescreen’s outer surface.

❺ Debris moves to the sump area of the strainer where it isremoved by periodic flushing.

SPECIAL FEATURES PROVIDE CONVENIENCEAND HIGH PERFORMANCE.

❻ External scraper adjustment.

❼ O-rings at the screen cover plate and shaft provide atight seal while allowing operation at low torque.

❽ Backwash system is available to remove debris from screen on low pressure applications except 2", 2-1/2" and 3" angle types and 3" D-type.

❾ Eductor is available at discharge for low-pressure applications.

❿ Brush can replace solid scraper on all but 2" and 2-1/2"Angle-type and 2-1/2" and 3" D-type.

OPERATING FEATURES THAT PROVIDE REAL BENEFITS

• Eliminate downtime for solids removalThe Hellan Strainer allows users to eliminate solids anddebris from fluids without stopping the flow of the fluid.Processes requiring the fluid continue uninterrupted.

• Employees are not exposed to possible contaminatesDebris that may include contaminates and hazardousmaterials is removed from the fluid flow without disas-sembly of the strainer. Maintenance personnel and otheremployees do not come into contact with this debris.

• Minimum labor requirements for solids removalThe Hellan Strainer reduces the time required to removesolids from the fluid flow. Manually-operated modelsrequire only a periodic turning of the handwheel toremove solids. Labor and cleaning time is usually lessthen 30 seconds. Labor requirements can be completelyeliminated with automatic strainers that can be con-trolled by timers and/or pressure differential switches.

❸❹

TO DRAIN

Page 9: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

7

UNIQUE OPERATING FEATURESWDA Type

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

❶ Fluid passes into the strainer and thru the screens.

❷ The screened fluid flows out of the strainer.

❸ Rotating the screen, by motor, moves the outer screen surface against the scraper bar. The scraper bar dislodges and removes collected debris from the screen’s outer surface.

❹ While the screen is rotating, the drain is opened and the debris is forced out through the drain in use.

❺ A drain separator is used to prevent the fluid velocity from pulling the debris away from the drain tube opening.

❻ Large inspection ports, sealed with O-rings, permit easy,external adjustment of the scraper bars and drain separators.

❼ O-rings at the screen shaft provide a tight seal while allowing operation at low torque.

❺❻

Page 10: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

STRAINER TYPES

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

8

INLINE FLOW BODY-SINGLE SCREEN

• Inline Flow, Manual Strainers (Type TSH) (Single ManualRotating Screen) (Sizes 1-1/2", 2", 2-1/2", 3") Type TSHHellan strainer employ a single handwheel equipped rotatingscreen and a rigid scraper bar to remove solids from the sur-face of the screen when the handwheel is rotated. A solids col-lecting sump is also provided. Cleaning of the Type TSH isaccomplished by opening a valve on the sump flush connec-tion and rotating the handwheel several times. For best results,the cleaning cycle should be performed when the strainer isunder a positive pressure. An educator and/or backwash mayaid in debris removal in low-pressure applications. Type TSHmust be installed in horizontal flow position as illustrated.

• Inline Flow, Automatic Strainers (Type TSA) (SingleMotorized Rotating Screen) (Sizes 1-1/2", 2", 2-1/2", 3") TypeTSA Hellan strainers employ a single, electric motor-drivenrotating screen and a rigid scraper bar to remove solids from thesurface of the screen when the screen is rotated. A solids collect-ing sump is also pro vided. Cleaning of the Type TSA is initiatedwhen the motor and flush valve operator are actuated. Controlsto accomplish these electrical functions are provided. For bestresults, the cleaning cycle should be performed when the strain-er is under a positive pressure. An educator and/or backwashmay aid in debris removal in low-pressure applications. TypeTSA must be installed in horizontal flow position as illustrated.

ANGLED FLOW BODY-SINGLE SCREEN

• Angled Flow, Manual Strainers (Type AH) (Single ManualRotating Screen) (Sizes 2", 2-1/2", 3") Type AH HellanStrainers employ a single hand-wheel equipped rotating screenand a rigid scraper bar to remove solids from the surface of thescreen when the handwheel is rotated. A solids collecting sumpis also provided. Cleaning of the Type AH is accomplished byopening a valve on the sump flush connection and rotating thehandwheel several times. For best results, the cleaning cycleshould be performed when the strainer is under a positivepressure. An educator and/or backwash may aid in debrisremoval in low-pressure applications. Type AH must beinstalled in vertical down-flow position as illustrated.

• Angled Flow, Automatic Strainers (Type AA) (SingleMotorized Rotating Screen) (Size 3" Only) Type AA HellanStrainers employ a single, electric motor-drive rotating screenand a rigid scraper bar to remove solids from the surface of thescreen when the screen is rotated. A solids collecting sump isalso provided. Cleaning of the Type AA is initiated when themotor and the flush valve operator are actuated. Controls toaccomplish these electrical functions are provided. For bestresults, the cleaning cycle should be performed when the strain-er is under a positive pressure. An educator and/or backwashmay aid in debris removal in low-pressure applications. Type AAmust be installed in vertical down-flow position as illustrated.

Page 11: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

9

STRAINER TYPESContinued

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

INLINE FLOW BODY-TWO SCREENS

• Inline Flow, Manual Strainers (Type DH) (Two ManualRotating Screens) (Sizes 2-1/2", 3", 4", 6", 8", 10", 12")Type DH Hellan Strainers employ two handwheel-equippedrotating screens and rigid scraper bars to remove solids fromthe surface of the screens when the handwheels are rotated.A solids-collecting sump is also provided. Cleaning of theType DH strainer is accomplished by opening a valve on the sump flush connection and rotating the handwheels several times. For best results, the cleaning cycle should beperformed when the strainer is under a positive pressure. An educator and/or backwash may aid in debris removal in low-pressure applications. Type DH can be installed invertical up-flow or horizontal flow position (with the draindischarging downward).

• Inline Flow, Automatic Strainers (Type DA) (Two Motor -ized Rotating Screens) (Sizes 4", 6", 8", 10", 12") Type DAHellan Strainers employ two electric motor-driven rotatingscreens and rigid scraper bars to remove solids from the surface of the screens when the screens are rotated. A solids-collecting sump is also provided. Cleaning of the Type DAstrainer is initiated when the motors and the flush valveoperator are actuated. Controls to accomplish these electricalfunctions are provided. For best results, the cleaning cycleshould be performed when the strainer is under a positivepressure. An educator and/or backwash may aid in debrisremoval in low-pressure applications. Type DA can beinstalled in vertical up-flow or horizontal flow position(with the drain discharging downward).

INLINE FLOW BODY-ONE SCREEN

• Inline Flow, Automatic Strainers (Type WDA) (Two Motor -ized Rotating Screens) (Sizes 20", 24", 30") and (Type WSA)(One Motorized Rotating Screen) (Sizes 14" and 16") TheseHellan Strainers employ two electric motor-driven rotatingscreens and rigid scraper bars to remove solids from the surface of the screens when the screens are rotated. A solidscollecting sump is also provided. Cleaning of the strainer isinitiated when the motors and the flush valve operator areactuated. Controls to accomplish these electrical functionsare provided. For best results, the cleaning cycle should beperformed when the strainer is under a positive pressure. An educator and/or backwash may aid in debris removal inlow-pressure applications. Type WDA and Type WSA mustbe installed in horizontal flow position as illustrated.Handwheel may be substituted for motorized drive butscreen may be difficult to rotate.

10.0

5.0

15.0

20.0

25.0PSID

NAMEPLATE

Page 12: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

STRAINER TYPESContinued

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

10

INLINE FLOW BODY-FOUR SCREENS

• Inline Flow, Manual Strainers (Type QH) (Four RotatingScreens*) (Sizes 14" and 16") Type QH Hellan Strainersemploy four handwheel-equipped rotating screens and rigidscraper bars to remove solids from the surface of the screenswhen the handwheels are rotated. A solids-collecting sump isalso provided. Cleaning of the Type QH strainer is accom-plished by opening one or both valves on the two sump flushoutlets and rotating the handwheels several times. For bestresults, the cleaning cycle should be performed when the strain-er is under a positive pressure. An educator and/or backwashmay aid in debris removal in low-pressure applications. TypeQH must be installed in vertical up-flow position as illustrated.

• Inline Flow, Automatic Strainers (Type QA) (Four Motor izedRotating Screens*) (Sizes 14" and 16") Type QA HellanStrainers employ four motor-driven rotating screens andrigid scraper bars to remove solids from the surface of thescreens when the motor-driven screens are rotated. A solids-collecting sump is also provided and equipped with twoelectrically-operated flush valves. Cleaning of the Type QAstrainer is initiated when the screen drive motors and flushvalve operators are actuated. Controls to accomplish theseelectrical functions are required. For best results, the clean-ing cycle should be performed when the strainer is under apositive pressure. An educator and/or backwash may aid indebris removal in low-pressure applications. Type QA mustbe installed in vertical up-flow position as illustrated.

INLINE FLOW BODY-SIX SCREENS

• Inline Flow, Manual Strainers (Type HH) (Six RotatingScreens*) (Size 20" only) Type HH Hellan Strainers employsix handwheel-equipped rotating screens and rigid scraperbars to remove solids from the surface of the screens when the handwheels are rotated. A solids-collecting sump is alsoprovided. Cleaning of the Type HH strainer is accomplishedby opening the valves on the two sump flush outlets and rotating the handwheels several times. For best results, thecleaning cycle should be performed when the strainer is undera positive pressure. An educator and/or backwash may aid indebris removal in low-pressure applications. Type HH must xbe installed in vertical up-flow position as illustrated.

• Inline Flow, Automatic Strainers (Type HA) (Six Motor izedRotating Screens*) (Size 20"only) Type HA Hellan Strainersemploy six motor driven rotating screens and rigid scraperbars to remove solids from the surface of the screens whenthe motor-driven screens are rotated. A solids-collectingsump is also provided and equipped with two electrically-operated flush valves. Cleaning of the Type HA strainer isinitiated when the screen drive motors and flush valveoperators are actuated. Controls to accomplish theseelectrical functions are provided. For best results, thecleaning cycle should be performed when the strainer isunder a positive pressure. An educator and/or backwash mayaid in debris removal in low-pressure applications. Type HAmust be installed in vertical up-flow position as illustrated.

15.010.0

25.0

20.05.0

PSID

10.0 15.0

25.0

20.05.0

PSID

Page 13: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

11

HOW TO SELECT A HELLAN STRAINER

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

There are seven application requirements that should beaddressed when selecting a specific Hellan Strainer model.Here are the considerations and options available for each requirement:

1 PERFORATION SIZE OF THE SCREENS

Hellan recommends that a screen perforation hole diameter be selected that is 40% to 60% of the diameter of the smallestorifice in the system. Selecting a smaller perforation thanrequired leads to unnecessary cleaning cycles and higher pressure drops during operation.

2 SIZE OF THE STRAINER

A) Existing Pipe Size MethodThis method is used when a Hellan Strainer is installed inan existing network of piping. Flow rate and the attendantpressure drop are within the application requirements.

In these situations, it is common practice to select a strainersize that matches the existing pipe size, i.e., an 8" strainerwould be selected for an installation with an existing 8" line.

B) Flow rate requirement versus pressure drop methodThis method should be utilized when selecting a strainer fora new application, or as a replacement strainer in existingsystems where a specific flow rate needs to be maintained.

Refer to the chart at right for flow rates of available strainersizes. Refer to the pressure drop versus flow rate charts forvarious size strainers, appearing on page 22.

C) High Concentration of SolidsFor removal of debris greater than 100 PPM, a solidseparator is recommended upstream of the Hellan strainer.

SCREEN OPTIONS

Perforated Screens Wedge-Wire Screens Round Opening Size Slot Width

Fractional Decimal Metric Mesh Micron Inches Metric Mesh Micron

1/4" .250" 6.35 mm 3 6350 .015" 0.38 mm 40 385

3/16" .188" 4.77 mm 4 4750 .009" 0.23 mm 60 230

1/8" .125" 3.18 mm 6 3175 *.007" 0.18 mm 80 180

3/32" .094" 2.38 mm 8 2450 *.005" 0.13 mm 100 140

1/16" .063" 1.59 mm 12 1588 *.004" 0.10 mm 150 100

1/32" .031" 0.79 mm 24 794Other perforated screen opening sizes and Wedge-Wire screen slot widths

are available upon request. See page 13 for complete information on screens.

*Consult factory for these applications .

STRAINER SIZE OPTIONS

Pipe Size Flow Pressure/flow Inches mm GPM* Liter/min.* data

1-1/2" 38 95 360

2" 51 95 360

2-1/2" 64 160 606

3" 76 235 890

4" 102 360 1363

6" 152 880 3331

8" 203 1450 5489 See Page 22

10" 254 2075 7855

12" 305 2750 10410

14" 356 4100 15520

16" 406 5300 20063

20" 508 8250 31230

24" 610 10650 40315

30" 762 16650 63027

*1.5 psid with clean 1/8" perforated screen.

D) Discharge Side of Pump It is recommended that a Hellan strainer be installed on the discharge side of a centrifugal pump with a minimumoperating pressure of 30 PSIG or 2 BAR. If operatingpressure is less, please contact the Hellan sales departmentfor assistance.

3 STRAINER CONSTRUCTION MATERIALS

Hellan Strainers are available with cast bodies constructed in iron, steel, stainless, and bronze or fabricated in steel and stainless steel. Other materials such as Super Duplex are available by special order. The material used for internal components depends on the material of the body.

The selection of a body material depends on three criteria:

A) The operating pressure of the systemThe body material selected should have a pressure ratingthat is appropriate for the operating pressure of the system.(See page 17 for maximum pressure ratings for strainers ofvarious materials and flange types.)

B) The fluid to be strainedStandard cast iron models are commonly used for freshwater applications, while other materials are used to meetspecial needs: cast stainless steel for highly corrosive fluids,and bronze or monel for seawater applications.

C) The environment in which the strainer operatesA longer service life may be attained by specifying a construction mate that is appropriate for the service envi-ronment. Stainless steel should be considered for highlycorrosive environments and bronze for marine or otherapplications where salt air is present.

Page 14: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

HOW TO SELECT A HELLAN STRAINERContinued

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

12

4 FLANGE REQUIREMENT

Strainers of cast iron construction are normally furnished with integral flanges that have dimensions in accordance with ANSIB 16.1, class 125 or class 250. Strainers of cast steel or caststainless steel are normally furnished with integral flanges thathave dimensions in accordance with ANSI B16.5, class 150 or class 300. Strainers of bronze construction are normally furnished with integral flanges that have dimensions in accor-dance with ASNI B16.24, class 150 or class 300.

Fabricated steel strainers are available with integral flanges inaccordance with ANSI B16.5 class 150 in 14" through 24" sizesand 125LW in 30" and 36" sizes or D.I.N. specifications

Special flanges to accommodate the bolting dimensions ofD.I.N. and other standards are also available.

Flange types should be selected using two considerations:

A) The flange on the strainer must match the mating flangeto which it is being attached.

B) The flange on the strainer should be appropriate for the system pressure.

(See page 17 for information on flanges and pressure ratings.)

5 BODY STYLE REQUIREMENTS

Hellan Strainers are available in angled flow and inline flowbody styles.

Angled flow body styles are available in 2", 2-1/2" and 3" sizes only.

Inline flow body styles are available in 1-1/2", 2", 2-1/2", 3", 4",6", 8", 10", 12", 14", 16", 20", 24", and 30" sizes.

36" strainers are custom designed and may be assembled on-site. No outline drawing is shown in this catalog.

6 METHOD OF OPERATION

Hellan Strainers are available with two methods of operation:

A) Manual operation utilizing a hand wheelB) Automatic operation for utilizing motorized screens

Automatic operation normally utilizes a pressure differentialswitch, automatic discharge valve and a control panel. A separate model number for the control panel must also bespecified. (See pages 18 and 19 for information on automaticstrainers and control panel options.)

7 AFTER YOU HAVE SELECTED A HELLAN STRAINER

After you have reviewed the above considerations and haveselected a Hellan Strainer for your particular application, wesuggest two additional steps be taken before ordering:

A) Check dimensional compatibilityOnce a Hellan Strainer model has been selected, the dimen-sions for the model be reviewed to make sure that appropriateclearances are available in the system design to accommodatethe dimensions of the strainer.

Dimensional information for Hellan Strainers modelsappears on pages 23 through 53.

B) Specifying a model numberA model number for the selected strainer may be specifiedby referring to the model number guide on pages 54 and55. Remember that, when specifying an automatic strainer,a separate model number for the control panel must also be specified.

Please contact the factory at 888-4-HELLAN for assistance.

Page 15: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

13

SCREEN OPTIONS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

MATERIALS AND FLANGE OPTIONS

Hellan Strainers are available with screens manufacturedfrom either perforated metal or wedge-wire materials.Information for standard perforated metal screen optionsand wedge-wire screen options are illustrated below.

STANDARD PERFORATED METAL SCREEN OPTIONS

1/32" Staggered(0.965 mm)16% open

1/16" Staggered(1.588mm)24% open

3/32" Staggered(2.381mm)33% open

Note: Other perforated screen sizes are available on specialorder. Please contact the factory for more information.Open area percentage shown for 1/16" & 1/32" above arefor double wrap over 1/4".

1/8" Staggered(3.175mm)40% open

3/16" Staggered(4.763mm)51% open

1/4" Staggered(6.350mm)58% open

STANDARD WEDGE-WIRE SCREEN OPTIONS

Note: Other wedge-wire slot width sizes are available on specialorder. Please contact the factory for more information.

Wedge-wire slots can be made to order. Standard slotsare listed below:

.015 27% open

.009 18% open

.007 15% open

.005 11% open

.004 9% open

Standard Hellan strainers are available in cast iron, cast steel,cast stainless steel, cast bronze and fabricated steel body construction. Each body material type is available with flangesin one of four configurations. Cast iron strainers are furnishedwith integral flanges in accordance with ASNI B16.1, class 125or class 250, or D.I.N. specifications. Fabricated steel strainersare available with integral flanges in accordance with ANSIB16.5 class 150 in 14" through 24" sizes and 125LW in 30".Note: NPT connections are only available on TSH/TSA strain-ers in cast iron or cast steel body construction.

Materials for internal strainer components vary, depending onthe body material.

Special flanges to accommodate D.I.N. or other requirementsare also available. Please contact the factory for complete information.

Hellan Strainers can be provided with a variety of internal and external coatings, such as epoxy, fuse coat epoxy, or otherfinishes for special applications.

Hellan Strainers can also be furnished in other materials and in flanged styles. Please contact the factory for completeinformation.

Page 16: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

COMPONENT MATERIALS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

14

STRAINER MATERIAL TYPE 7

Components Cast Iron Welded Steel Cast Steel Cast Stainless Steel Cast Bronze1 Body Cast Iron Carbon Steel Cast Steel Cast Stainless Steel Bronze

ASTM A278 Class 30 ASTM A36 ASTM A216 WCB ASTM A351 CF8M C-95800Screen Bushing N/A Bronze Bronze Bronze N/A

2 Inspection Cover Cast iron Carbon Steel Carbon Steel Cast Stainless Steel BronzeASTM A278 Class 30 ASTM A29 1018 ASTM A351 CF8M C-95800

3 Scraper Blade5 Manganese Bronze 316 Stainless Steel Manganese Bronze 316 Stainless Steel Cast MonelASTM A494 Grade M35-1

4 Clamp Bar5 Red Brass 316 Stainless Steel Red Brass 316 Stainless Steel Cast MonelASTM A494 Grade M35-1

5 Screen Plate Cast Iron Carbon Steel Cast Steel Cast Stainless Steel BronzeASTM A278 Class 30 ASTM A216 WCB ASTM A351 CF8M4 C-95800

6 Shaft Plate Carbon Steel Carbon Steel Carbon Steel 316 Stainless Steel BronzeC-93800

7 Hand Wheel Cast Iron N/A Cast Iron Cast Iron BronzeZinc Plated ASTM B61

8 Shaft 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400UNS N04400

9 Screen1 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400UNS N04400

10 Drain Separator N/A 316 Stainless Steel N/A N/A N/A11 Drain Tube N/A 316 Stainless Steel N/A N/A N/A12 3-way Ball Valve4 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel13 Deflector2 316 Stainless Steel N/A Carbon Steel 316 Stainless Steel Monel 400

UNS N0440014 Apron2 316 Stainless Steel N/A 316 Stainless Steel 316 Stainless Steel Monel 400

UNS N0440015 Wetted Fasteners 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400

UNS N0440016 External Fasteners Medium Carbon Steel 316 Stainless Steel Medium Carbon Steel 316 Stainless Steel Monel 400

UNS N0440017 O-Rings Nitrile (Buna N) Nitrile (Buna N) Nitrile (Buna N) Viton Viton18 Keys 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400

UNS N0440019 Collar 303 Stainless Steel 303 Stainless Steel 303 Stainless Steel 303 Stainless Steel 303 Stainless Steel20 Washer Sintered Bronze Sintered Bronze Sintered Bronze Sintered Bronze Sintered Bronze21 Motorized Drive4 Cast Iron Cast iron Cast Iron Cast Iron Bronze

(Housing Adapter) ASTM A278 Class 30 ASTM A278 Class 30 ASTM A278 Class 30 ASTM A278 Class 30 C-9380022 Motorized Valve Body4 Cast 316 Stainless Cast 316 Stainless Cast 316 Stainless Cast 316 Stainless Bronze

Ball and Stem Stainless Steel Stainless Steel Stainless Steel Stainless Steel BronzePacking and Seat PTFE PTFE PTFE PTFE PTFE

23 Swage Nipple4 Carbon Steel N/A Carbon Steel Stainless Steel Monel 400ASTM A234 ASTM A234 T-304 ASTM B61

24 Pressure Switch4 316 L Stainless 316 L Stainless 316 L Stainless 316 L Stainless 316 L StainlessDiaphragm Viton Viton Viton Viton VitonSeals Viton Viton Viton Viton Viton

25 External Fittings5 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400UNS N04400

26 External Tubing 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Monel 400UNS N04400

27 Lubricant3 Mobil Grease XHP 200 Mobil Grease XHP 200 Mobil Grease XHP 200 Mobil Grease XHP 200 Mobil Grease XHP 20028 External Paint7 Kemaqua 70P Kemaqua 70P Kemaqua 70P N/A N/A

Notes: 1) Comprise a welded assembly.2) Deflector and apron are only in 14", 16" and 20" strainers.3) Lubricant is applied to threaded fasteners, thrust washers and press fit parts.4) Motorized components are used only on automatic strainers.

5) Strainers in sizes of 2"and 2-1/2" with single screens and 2-1/2" and 3" with dual screenshave scraper blades integral with the body and do not use clamp bars.

6) Other coatings, such as epoxy, fuse coat epoxy and other special coatings are availableupon request.

7) Body and component materials, other than those listed above, are available upon request.

Page 17: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

15

COMPONENT MATERIALS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

The following drawings and chart list the standard com-ponent materials of construction for Hellan Strainers ofvarious body materials.

~

1314

2121

2223

24

12

26

25

1

16

2

34

517

6

DUAL SCREEN CONFIGURATION2-1/2" THRU 12"

4 SCREEN CONGIURATION14" AND 16" SIZE ONLY

SINGLE SCREEN CONFIGURATION1-1/2" THRU 3"CAN BE AUTOMATIC

ADAPTERGEARBOX

AUTOMATIC CONFIGURATION ONLY

17

7

81920

9

15

18

LC

78

165

24

91

317

1518

1920

6

17

The materials listed may change without notice and do notapply to non-standard strainers.

Page 18: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

COMPONENT MATERIALS

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

16

BB

WELDED BODY CONSTRUCTION

14" AND 16" (SINGLE DRIVE AND DRAIN)20" THRU 30" (DUAL DRIVE AND DRAIN)

VIEW B-B

GEARBOX

ADAPTOR

6 3 15 10 17 11

8

2

9

17

5

16

17

1

11

21

21

18

6

20

19

17

17

12

24

2122

2

CCW ROT. MTR.

CCW ROT.MTR.

Page 19: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Standard Product, Pressure Ratings and Flow Rates

StrainerType

FlowRate

Cast iron Cast Steel Stainless Steel Cast Bronze Carbon Steel (FAB)

Carbon Steel (FAB)

NPTClass125

Class250 NPT

Class150

Class300

Class150

Class300

Class150

Class300

ANSIISO

AWWA125 LW

GPMliter/min.

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

PSIBAR

1-1/2” & 2” TS107 175 285 275 220405 12.1 19.6 19.0 15.2

2-1/2” & 3” TS159 175 285 275 220602 12.1 19.6 19.0 15.2

2” Angle107 175 285 275 220405 12.1 19.6 19.0 15.2

2-1/2” Angle145 175 285 275 220549 12.1 19.6 19.0 15.2

2-1/2” D-Type193 175 285 275 220730 12.1 19.6 19.0 15.2

3” Angle190 175 285 275 220719 12.1 19.6 19.0 15.2

3” D-Type290 175 285 275 2201098 12.1 19.6 19.0 15.2

4” D-Type354 175 350 285 450 275 450 220 4501340 12.1 24.1 19.6 31.0 19.0 31.0 15.2 31.0

6” D-Type842 175 350 285 450 275 450 220 4503187 12.1 24.1 19.6 31.0 19.0 31.0 15.2 31.0

8” D-Type1464 175 350 285 450 275 450 220 4505541 12.1 24.1 19.6 31.0 19.0 31.0 15.2 31.0

10” D-Type2013 175 350 285 450 275 450 220 4507619 12.1 24.1 19.6 31.0 19.0 31.0 15.2 31.0

12” D-Type2623 175 350 285 450 275 450 220 4509928 12.1 24.1 19.6 31.0 19.0 31.0 15.2 31.0

14” Q-Type4270 150

16,162 10.3

16” Q-Type5368 150

20,318 10.3

20” H-Type7930 150

30,015 10.3

14” WSA4270 75

16,162 5.2

16” WSA5368 75

20,318 5.2

20” WDA7930 75

30,015 5.2

24” WDA10,980 7541,559 5.2

30” WDA16,470 7562,339 5.2

STANDARD FLOW RATES AND PRESSURE RATINGS

The table below summarizes standard product, provides pressure ratings and shows the flow rate that will produce 1.5 psi ofpressure drop with a 1/8" perforated screen. See page 22 for other screen options. Page 22 shows the flow rates that will produce1.0 psi of pressure drop.

17

Note: Pressure ratings shown are for maximum temperature of 100°F for steel and stainless steel and 150°F for cast iron and bronze. Contact the factory for higher temperature.

Page 20: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

18

AUTOMATIC STRAINERS

Automatic Hellan Strainers are used whenever automaticself-cleaning of the strainer is required or advantageous.Under normal operating conditions, these units can performa complete cleaning cycle in just 15 seconds.

OPTIMIZED CLEANING

Automatic cleaning allows you to optimize the cleaning cyclewhile you minimize maintenance labor costs. It provides thebest cleaning action by simultaneously rotating the cleaningscreen and opening the discharge valve which creates lessdebris out.

A balance must also be struck between the fluid discharge during a cleaning cycle and pumping efficiency across aclogged strainer. Clean too soon and you waste some fluid inthe discharge. Clean too late and cleaning may be impaired.

The Hellan Automatic Strainer enables you to tailor the cleaning cycle to your specific needs. You set a timer to cleanwhenever you choose.

Cleaning should be performed in time to keep pressure drop lessthan four times the clean pressure drop. Not to exceed 8 PSID.

AUTOMATIC STRAINER SIZES

Automatic strainers, in cast body construction, are available in 1-1/2" through 20" pipe sizes. The 1.5"– 3" strainers (singlescreen) are furnished with one 1-1/2" discharge valve; the 4"through 12" (dual screens) are furnished with one 2" dis-charge valve; the 14" and 16" (4 screens) and 20" (6 screens)are furnished with two 2" discharge valves to obtain the optimum flushing action.

Automatic strainers, in fabricated body construction, areavailable in 14" through 30" pipe sizes. The 14" and 16" arefurnished with two 2" discharge valves; the 20" and 24" arefurnished with two 3" discharge valves; the 30" is furnishedwith two 4" discharge valves to obtain the optimum flushing action.

ELECTRICAL COMPONENTS

The basic components of the self-cleaning strainer are the differential pressure switch, the screen drive, the actuated discharge valve and the control panel.

The drive replaces the handwheel and rotates each screen at approximately 17 RPM.

An actuated ball valve opens and closes the waste dischargeport. To sense the clogging of the screen, a differential pressureswitch monitors pressure drop across the strainer.

The control panel synchronizes the screen drives and the discharge valve to achieve the optimum cleaning cycle. This cleans the screens without excessive discharge of the system fluid.

IEC STANDARDS

Motors are available to meet or exceed the following IEC standards: 1P21, 22, 23, 44, 54, 55, 56, 57, 65, 67 and 68.

SELECTION OF AUTOMATIC STRAINER MODEL

To select an automatic strainer and specify a model number,see the information on selecting and specifying a strainermodel on pages 52-53.

EASY CONVERSION TO AUTOMATIC OPERATION

The strainer can be converted from manual to automatic operation in three easy steps.

1

2

3

Page 21: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

19

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

AUTOMATIC STRAINERS

HAND/OFF/AUTOMATIC

The rotary H-O-A selector switch allows for three modes ofoperation. In the “Hand” position, the screen drives and flushvalve will be actuated until the switch is returned to off.

In the “OFF” position, the self-cleaning cycle does not function.

In the “AUTOMATIC” mode, there are three ways to initiate a cleaning cycle:

1. Differential pressure switch. As the screen becomes clogged,the pressure drop will increase. At a preset point, a cleaningcycle will start.

2. Internal timer. An automatic interval between cleaningcycles can be set from zero to 100 hours.

3. Manual start. A momentary push-button on the controlpanel will start a cleaning cycle.

SYSTEM SAFETY MONITORS

The control panel is a constant indicator of the status of yoursystem. For example, a panel light illuminates when power isapplied to the strainer motor relay.

If the strainer basket is not thoroughly cleaning during the normal cleaning cycle, the pressure drop continues to increase,causing the high pressure alarm light to illuminate.

This alarm is self-resetting when the differential pressure dropfalls below the set point.

REMOTE OPERATIONS

Manual Cycle StartYou may attach a normally open, momentary push-button tothe control panel terminal strip. The H-O-A switch must be inthe AUTOMATIC position for the cycle to start.

High Pressure Alarm OptionA set of contacts controlled by the high pressure alarm light isavailable as an option.

Hand/Off/AutomaticIf you require these functions at a remote location, the controlpanel H-O-A switch must be disconnected.

IEC STANDARDS

NEMA 12 controls panels meet or exceed IEC IP10 through IP65.

NEMA 4 control panels meet or exceed IEC IP66.NEMA 4X control panels meet or exceed IEC 529 IP66.Control panels are also available with IEC components.

SELECTION OF AUTOMATIC STRAINER CONTROL

Strainer controls are ordered separately from the strainer. Theselection of the control is based on both the number of motors(i.e., “AA”, “SA” & “TSA” types have one motor; “DA” & “WDA”types have two motors; “QA” types have four motors and “HH”types have six motors) and their voltage. The voltage to thecontrol panel must be the same as the motor voltage. To selecta control panel and specify a model number, see the infor -mation on selecting and specifying a control panel model onpage 53.

13”

13”

OTHER OUTSIDECONNECTIONS

PLC

TRANSFORMERFACTORY WIRED

FOR 230 OR460 VOLTS.NONE FOR115 VOLTS.

MAINSWITCH

CONTROL RELAYS

STARTER

OVERLOADRELAYS

MOTORCONNECTIONS

GND

GND

17”

20.25”

MAINSWITCH

SERIAL NUMBERPLATE

WARNINGPLATE

POWERON

CLEANINGCYCLE IN

PROGRESS

CYCLESTART

OFFHAND AUTO

HIGHPRESSURE

Page 22: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

20

EXTERNAL SCRAPER ADJUSTMENT

As an option, TS and D-type Hellan strainer are equipped toallow for adjustment of scrapers or brushes from outside thebody without opening the pressure vessel. The accompanyingfigure illustrates this feature. The scraper or brush is held inplace by two pulling pins to which it is bolted. The outwardend of each pulling pin penetrates the pressure vessel throughthe scraper support cover. Both pulling pins are o-ring sealed.The outward ends of the pulling pins are also threaded allow-ing pulling screws to be tightened against the pulling cover.The scraper or brush is pulled against a jack screw which holdsit in the correct location relative to the screen surface.

A

A

B

B

VIEW A-A

VIEW B-B

JACK SCREW

PULLING COVER

PULLING PIN

SCRAPER SUPPORT COVER

SCRAPER OR BRUSH

SCREEN SURFACE

O-RING SEAL

PULLING SCREW

Once the scraper or brush is adjusted at the factory, it can bereadjusted to compensate for wear. Brushes should be set tobear against the wedge wire screen surface. Scrapers should be set so that they are .005 to .010 inches away from theperforated screen surface. To accomplish this adjustment, thepulling screws should be loosened and then the scraper orbrush should be moved inward until it is against the screensurface. This is done by turning the jack screw clockwise. Care should be taken not to over tighten the jack screw. The pulling screws should be turned clockwise until they just bear on the pulling cover. If a brush is in use, the pullingscrews should be tightened securing the brush against the jack screw. If a scraper is in use, the jack screw should berotated approximately 45 degrees counterclockwise. Then the pulling screws should be tightened securing the scraperagainst the jack screw.

Page 23: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

21

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

PRESSURE SWITCH AND THREE WAY BALL VALVE

The pressure switch is used to initiate a cleaning cycle whenthe differential pressure across the strainer reaches a pre setlevel. It is used to indicate when the differential pressure is toohigh by an indicator light on the control panel. The pressureswitch has two switches with contacts that close when theseevents take place. The levels at which these contacts close canbe adjusted by turning the marked adjustments on each endof the electrical housing of the switch. The pressure that existsacross the pressure switch can be read from a 0-25 psid gaugeon the switch assembly. The points are factory pre set at 4 psid and 8 psid respectively. However, there is no means todetermine these set points if they are moved from the factorypre sets. This is the purpose of the three way ball valve. As canbe seen from the accompanying figure, the ball valve is

connected between the Lo port of the pressure switch and the Lo port of the strainer. When the handle of the ball valveis horizontal, the ends of the valve are connected and nopressure exists across the valve. However, as the handle isslowly rotated clockwise, the valve port connected to thestrainer is restricted and the valve port pointed down allowsthe Lo port of the pressure switch to vent. As this happens, the gauge reading will slowly increase. The pressure levels atwhich the set-points are set is determined by viewing thepressure reading at which the cleaning cycle initiates and thehigh pressure indicator on the control panel illuminates. Todo this the pressure in the strainer must be greater that thehigh set-point of the pressure switch.

DP SWITCH/GAUGE

CONNECT TO LO PRESSURESTRAINER PORT

CONNECT TO HI PRESSURESTRAINER PORT

LO PRESSURE GAUGE PORT

HI PRESSURE GAUGE PORT

25.0

15.0

20.0

10.0

5.0

PSID

Page 24: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Outline Page Cv @ Screen Opening (percent of open area)

Hand Auto1/4

(58%)3/16

(51%)1/8

(40%)3/32 (33%)

1/16 (24%)

1/32 (16%)

.015 (27%)

.009 (18%)

.007 (15%)

.005 (11%)

.004 (9%)

1-1/2" & 2" TS 21 36 90.52 89.83 88.00 85.91 80.80 70.69 82.96 74.05 68.72 58.28 51.12

2-1/2" & 3" TS 22 37 133.6 132.6 130.0 127.0 119.6 105.0 122.8 110.0 102.1 86.81 76.25

2" Angle 23 90.52 89.83 88.00 85.91 80.80 70.69 82.96 74.05 68.72 58.28 51.12

2-1/2" Angle 24 121.7 121.0 119.0 116.7 110.9 99.92 113.4 103.0 96.50 83.29 73.84

2-1/2" D-Type 26 162.7 161.7 159.0 155.9 148.1 132.1 151.5 137.5 128.9 111.2 98.56

3" Angle 25 38 159.6 158.6 156.0 153.0 145.4 129.6 148.6 135.0 126.5 109.1 96.72

3" D-Type 27 243.5 242.0 238.0 233.4 221.8 197.8 226.7 205.9 193.0 166.6 147.7

4" D-Type 28 39 295.8 294.2 290.0 285.1 272.7 246.2 278.0 255.3 240.8 210.3 187.8

6" D-Type 29 40 698.1 693.1 690.0 664.9 627.7 556.9 643.5 577.9 538.2 459.2 404.2

8" D-Type 30 41 1235 1255 1200 1171 1101 962.4 1131 1008 935.4 792.7 695.0

10" D-Type 31 42 1695 1683 1650 1612 1519 1334 1553 1396 1292 1104 970.1

12" D-Type 32 43 2200 2186 2150 2108 2003 1786 2048 1860 1743 1504 1333

14" Q-Type 33 44 3609 3579 3500 3410 3193 2770 3284 2909 2689 2265 1929

16" Q-Type 34 46 4507 4477 4400 4310 4087 3629 4182 3784 3538 3041 2689

20" H-Type 35 49 6653 6611 6500 6372 6050 5388 6187 5612 5254 4528 4010

14" WSA 45 3609 3579 3500 3410 3193 2770 3284 2909 2689 2265 1979

16" WSA 47 4507 4477 4400 4310 4087 3629 4182 3784 3538 3041 2689

20" WDA 48 6672 6624 6500 6357 6003 5290 6153 5529 5150 4396 3871

24" WDA 50 9207 9151 9000 8826 8389 7485 8576 7791 7303 6304 5590

30” WDA 51 13,890 13,782 13,500 13,178 12,390 10,834 12,134 11,351 10,531 8927 7828

FLOW RATE VS PRESSURE DROP

The accompanying table lists the flow rate (Cv), in gallons perminute of water that will result in 1.0 pounds per square inchof differential pressure across the size and type of strainershown in the left-hand column with the screen opening shownacross the top.

PRESSURE LOSS CACULATION USING CV FACTOR

Standard Units Metric Units

dP � [ Q ]2dP � [ Q ]2

(133.6)Cv Cv

Q = Flow in GPM Q = Flow in M3/hrCv = Flow Coefficient Cv = Flow CoefficientdP = Pressure Drop in psi dP = Pressure Drop in kPa

The pressure loss across a strainer can be calculated using the system’s flow rate and the Cv factor for that strainer.

22

Page 25: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

23

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

1-1/2" & 2" MANUAL STRAINERIn-Line Flow Type TSH

1-1/2" NPTCAST IRON1-1/2" NPT

CAST STEEL and STAINLESS STEEL2" NPT

CAST IRON2" NPT

CAST STEEL and STAINLESS STEEL

THREAD SIZE

1-1/2"

2"

STRAINERSIZE

22 Kg49 Lb21 Kg

49 Lb22 Kg46 Lb

46 Lb21 Kg

APPROX.WEIGHT

INLET

SCRE

EN R

EMO

VA

L

(84mm)3.31Ø

OUTLET

14.50(423mm)

(206mm)8.12

7.50(190mm)

10.06(225mm)

11.69(297mm) 7.00Ø

(178mm)

ORIENTATION - DRAIN MUST BE DOWN.THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

1" NPTSOLIDS FLUSH OUTLET VIEW A-A

WALL

(OPTIONAL BY REQUEST)

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

EXTERNAL SCRAPER ADJUSTMENT

A A

Page 26: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

24

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

1-1/2" NPTSOLIDS FLUSH OUTLET

ORIENTATION - DRAIN MUST BE DOWN.

WALL

VIEW A-A

OUTLET

16.00

(117)4.62

(406)

(294)SCRE

EN R

EMO

VA

L

11.59

(242)9.54

INLET (248)9.75

13.61(346)

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

(OPTIONAL BY REQUEST)

7.00(178)

EXTERNAL SCRAPERADJUSTMENT

2-1/2"

3"

STRAINERSIZE

APPROX.

84 Lb38 Kg

WEIGHT

40 Kg89 Lb

84 Lb38 Kg89 Lb40 Kg

A A

2-1/2" NPTCAST IRON2-1/2" NPT

CAST STEEL and STAINLESS STEEL3" NPT

CAST IRON3" NPT

CAST STEEL and STAINLESS STEEL

THREAD SIZE

2-1/2" & 3" MANUAL STRAINERIn-Line Flow Type TSH

Page 27: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

25

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

2" MANUAL STRAINERAngled Flow Type AH

6.00

B

B 8.50

(178mm)7.00

A

5.62

INLET

OUTLET

C

13.81(351mm)

(MINIMUM CLEARANCEFOR SCREEN REMOVAL)

1 1/4 " NPT BALL VALVE

(OPTIONAL BY REQUEST)

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

.75 DIA (19mm)

(92mm)3.62

(51mm)2.00

4 HOLES

.06(1.5mm)

4.75

125mmfor D.I.N.

18mmfor D.I.N.

(121mm)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN

WAL

L

CLASS 150 FLANGEFOR ANSI FLANGE TOP & SIDE

4.56114

116

4.50

ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.IS IN ACCORDANCE WITH D.I.N. STANDARDS.

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)

DIN 2501

FLANGE SIZE

CAST IRONANSI class 150CAST STEEL &

ANSI class 125

50 DN 10

STAINLESS STEEL

10.50INCH

MMINCHMM

26910.56267

A55 Lb.69

19.7518

26 Kg58 Lb25 Kg

B C APPROX.WEIGHT

Page 28: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

26

A

B

B9.12

6.25

7.00(178mm)

C

(232mm)

INLET

OUTLET

7.00(178mm)

(OPTIONAL BY REQUEST)

1-1/2" NPT BALL VALVE

(OPTIONAL BY REQUEST)STRAIGHT NIPPLE

FOR SCREEN REMOVAL)

(MINIMUM CLEARANCE

(392mm)15.44

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN

(64mm)

(105mm)4.12

2.50 (140mm)5.50

145mmfor D.I.N.

18mmfor D.I.N.

.75 DIA (19mm)

.06(1.5mm)

4 HOLES

WA

LL

TOP & SIDEFOR ANSI FLANGECLASS 150 FLANGE

65 DN 10

ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.IS IN ACCORDANCE WITH D.I.N. STANDARDS.DIN 2501

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)

ANSI class 125CAST IRON

ANSI class 150CAST STEEL &

STAINLESS STEEL

FLANGE SIZE12.00INCH

MM

MMINCH

310

30512.19

A.69

22.88

5.00

5.19132

127

B70 Lb

18

34 Kg74 Lb32 Kg

C APPROX.WEIGHT

2-1/2" MANUAL STRAINERAngled Flow Type AH

Page 29: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

27

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

3" MANUAL STRAINERAngled Flow Type AH

IS IN ACCORDANCE WITH D.I.N. STANDARDS.ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)

INCH

INCHMM

MMSTAINLESS STEEL

80 DN 10DIN 2501

CAST STEEL &ANSI class 150

FLANGE SIZEANSI class 125

CAST IRON14.19360

A14.00356

FOR ANSI FLANGECLASS 150

TOP & SIDEFLANGE

5.69144

.9424

B5.50140

C.7519 46 Kg

105 Lb48 Kg

WEIGHTAPPROX.

101 Lb

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN

(127mm)

3.00(76mm)

5.00

6.00

100mmfor D.I.N.

18mm8 HOLESfor D.I.N.

(152mm)

FOR SCREEN REMOVAL)(MINIMUM CLEARANCE

OUT

LET

.75 DIA (19mm)(1.5mm)

.06

4 HOLES

1-1/2" NPTSOLIDS FLUSH OUTLET

(159mm)6.25

C

B

7.50(191mm)

(191mm)7.50

B (235mm)

INLETC

9.25

(438mm)17.25

FLANGED INSPECTION OPENINGO-RING SEALED

3.75 (95mm) DIA.

A

(STANDARD)

10.00(254mm)

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

1 1/2 " NPT BALL VALVE

(OPTIONAL BY REQUEST)

WA

LL

Page 30: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

282.50

(63.5mm)

5.50

145mmfor D.I.N.

18mmfor D.I.N.

(140mm)

.75 DIA (19mm)(4) HOLES

4.12(105mm)

7.00(178mm)

(1.5mm).06

D

G

C

B

D

7.00(178mm)

7.00

3.00 3.50

9.67

5.57

21.74

10.87

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

1 1/2 BALL VALVE(OPTIONAL BY REQUEST)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN

(413mm)16.25

FOR SCREEN REMOVAL)(MINIMUM CLEARANCE

WAL

L

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)IS IN ACCORDANCE WITH D.I.N. STANDARDS.

ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.

FLANGE SIZE

CAST IRONANSI class 125

DIN 250165 DN 10

INCH

INCHMM

MM3.5089

3.6292

B4.691194.81122

C12.00

12.25.8822

.7519

D

311

305

G WEIGHTAPPROX.

100 Lb45 Kg105 Lb48 KgSTAINLESS STEEL

CAST STEEL &ANSI class 150

INLET

OUTLET

2-1/2" MANUAL STRAINERIn-Line Flow Type DH

Page 31: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

29

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

3" MANUAL STRAINERIn-Line Flow Type DH

23.94

11.97

5.83

7.00

G

13.56

B

C

7.50

4.383.75D

.75 DIA (19mm)4 HOLES

6.00(152mm)

3.00(76mm)

D

.06 (1.5mm)

5.00(127mm)

7.50

STRAIGHT NIPPLE(OPTIONAL BY REQUEST)

2" BALL VALVE(OPTIONAL BY REQUEST)

2" THREADED FLANGE(STANDARD)

(441mm)(MINIMUM CLEARANCEFOR SCREEN REMOVAL)

17.38

ORIENTATION - DRAIN MUST BE DOWNTHESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

WA

LL

TOP & BOTTOM FLANGESFOR ANSI FLANGE CLASS 150

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)IS IN ACCORDANCE WITH D.I.N. STANDARDS.

ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.

INCHMM

MM

INCH

FLANGE SIZE

STAINLESS STEELCAST STEEL &ANSI class 150

CAST IRONANSI class 125

DIN 250180 DN 10

2.0648

52

1.88

1254.94

B

1214.75

.9424

D

19.75

61 Kg145 Lb66 Kg

WEIGHTAPPROX.

135 Lb

C G13.0033013.38340

160mmfor D.I.N.

18mm8 HOLESfor D.I.N.

1/4 NPT ONLET GAUGE PORT

INLET

OUTLET

Page 32: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

30

1/4 NPT ONLET GAUGE PORT

1/4 NPTOUTLET GAUGE PORT

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE A CB D E FINCH

INCH

INCH

INCH

DIN 2501100 DN 16

100 DN 10

ANSI class 300CAST STEEL &

STAINLESS STEEL

DIN 2501

ANSI class 250CAST IRON

CAST IRONANSI class 125

1686.60

MM6.31160114

4.50 6.9417632

1.25254

10.00

6.00

6.00

6.316.60 4.50

1606.29168MM

MM

160

1521064.19114

6.29160MM 152106

4.19

6.941.25 10.00176

1576.19

32

24.94

254

2299.00

NANA24

.942299.00

FOR ANSI FLANGE CLASS250, 150, 300 & DIN

FE

D

(254)10.00

.06 (1.5mm)

R

ACCESS CLEARANCE)(MINIMUM SCREEN

A

(523mm)

WAL

L

20.59

(358mm)14.09

(716mm)28.18

(HOLES)G H RM FLANGE SIZE

2-1/2" NPT

7.88200

16.62422

.8822

88 393

15.4714.10358 2" NPT

.8887.8816.622007.50

422

19140616.00

22

19.75

8

88

7.50191

16.00406

DIA..7519

No.88

15.4712.54

38515.16393318

35013.79

2" NPT

2" NPT

15.16385

16.41416

200 Lb90 Kg

190 Lb

82 Kg

86 Kg180 Lb

77 Kg170 LbWEIGHT

N DRAIN

TOP & BOTTOM FLANGES

J

H 4.00(102mm)

J

APPROX.

M

G

C

STRAIGHT OR SWAGE NIPPLE (BY REQUEST)

(OPTIONAL BY REQUEST)

N-THREAD DRAIN FLANGE(STANDARD)

B

2" NPT SOLIDSFLUSH OUTLET

EXTERNAL SCRAPER ADJUSTMENT

ANSI class 150CAST STEEL &

STAINLESS STEEL

INLET

OUTLET

INCH

INCH

1686.60

MM6.31160114

4.50 6.9417632

1.25254

10.00

6.001606.29

MM 1521064.19

1576.19

24.94

2299.00

7.09180

16.62422

.7118

88 393

15.4714.10358 2" NPT

7.09180406

16.0018.71

88

38515.16

35013.79 2" NPT

200 Lb90 Kg

82 Kg180 Lb

4" MANUAL STRAINERIn-Line Flow Type DH

Page 33: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

31

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

6" MANUAL STRAINERIn-Line Flow Type DH

(OPTIONAL BY REQUEST)

TOP & BOTTOM FLANGES

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE

CAST IRONANSI class 125

ANSI class 300

CAST IRONANSI class 250

DIN 2501150 DN 16DIN 2501

150 DN 10STAINLESS STEEL

CAST STEEL &

.06 (1.5mm)

NANA

9.69246

9.692168.50

246INCH 9.23MM 234

INCH

INCH

INCH

8.79

9.23MM

MM 223

234

8.79MM 223

A

5.31135 192

7.56 1.4437

135

1244.88

5.31192

181

7.56

7.12

89

B3.50

181

C7.12

1.44

1.0037

25

1.0025

D E

250, 150, 300 & DINFOR ANSI FLANGE CLASS

EF

20.88530

12.50318

10.62270

50820.00

53020.88

50820.00

27911.00

12.50318

27911.00

F

27010.62

2419.50

G

2419.50

H

19.001212

.8822 483 460

18.12

18.95

19.62

19.061212

88

22.88

22.88

(HOLES)

8

JNo.8

22.88DIA.

484

498 44917.68460

18.12481

M R

44917.68

D

H

(254)10.00

A

WAL

L

INLET

(MINIMUM SCREEN

OUTLET

(1124 mm)44.28

22.14(561 mm)

31.00

G

R

3.25 (82mm)

O-RING SEALED

SCREEN INSP.OPENING,

B

455 Lb207 Kg2 1/2"

182 Kg400 LbWEIGHTAPPROX.

195 Kg430 Lb193Kg425 Lb

3"

2 1/2"

3" NPT

FLANGE SIZEDRAINN

6.00(152mm)

J

M

C

(OPTIONAL BY REQUEST)SWAGE NIPPLE

N-THREADDRAIN FLANGE (STANDARD)

2" NPT SOLIDSFLUSH OUTLET

EXTERNALSCRAPER ADJUSTMENT

ANSI class 150CAST STEEL &

STAINLESS STEEL

9.692168.50

246INCH 9.23MM 234

INCH 8.79MM 223

5.31135 192

7.56 1.4437

1244.88

1817.12 1.00

2520.88530

12.50318

9.45240

50820.00

27911.00

2409.45

19.0088

.8122 483 460

18.12

19.6288

18.71

498 44917.68

455 Lb207 Kg2 1/2"

195 Kg430 Lb3"

1/4 NPT ONLET GAUGE PORT

Page 34: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

32

DIN 2501200 DN 10

DIN 2501200 DN 16

CAST IRONANSI class 250

ANSI class 125CAST IRON

STAINLESS STEELCAST STEEL &ANSI class 300

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE

11.75298

11.75

13.00330

298

13.00330255

10.042429.54

MM

INCH

INCHMM

149 232

5.381375.88

8.622199.12

2429.54

25510.04

INCH

INCHMM

MM

A5.38 8.62137

1495.88

219

2329.12

B C

34313.50

15.0038141 303

11.94

10.621.1229

1.62270

635

24.00610

25.00

34313.50

38115.00

NA1.12

11.9429

411.62

NA

303

D E24.00610

63525.00

GF H

318 kg.700 lb.WEIGHT

341 kg.750 lb.

750 lb.

800 lb.364 kg.

341 kg.

APPROX.

21.56548

22.1256212 25

.88

1.00

8812

22

59223.32

22.82580

54821.56

55822.00

M.88

1.0088

1212

22

25

(HOLES)No.J

DIA.

23.32

22.82580

592

R

(821mm)32.32

H

TOP & BOTTOM FLANGESFOR ANSI FLANGE CLASS

250, 150, 300 & DIN

EF

CD

.06 (1.5mm)

(203mm)8.00

J

M

C

B

(1160mm)

(580mm)22.82

45.64

ACCESS CLEARANCE)(MINIMUM SCREEN

4.50 (114mm)

OPENING,SCREEN INSP.

O-RING SEALED

(OPTIONAL BY REQUEST)

(OPTIONAL BY REQUEST)SWAGE NIPPLE

2" NPT SOLIDSFLUSH OUTLET

ANSI class 150CAST STEEL &

STAINLESS STEEL

A

(381)15.00

INLET

R G

OUTLET

(OPTIONAL BY REQUEST)DRAIN FLANGE4" THREADED EXTERNAL

SCRTAPERADJUSTMENT

WAL

L

11.61295

11.611295255

10.042429.54

MM

INCH

INCHMM

149 232

5.381375.88

8.622199.12

34313.50

15.0038141 303

11.94

10.621.1229

1.62270

635

24.00610

25.00

750 lb.

800 lb.364 kg.

341 kg.21.56548

22.1256212 22

.87

.87

8812

22

59223.32

22.82580

1/4 NPT ONLET GAUGE PORT

8" MANUAL STRAINERIn-Line Flow Type DH

Page 35: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

33

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

10" MANUAL STRAINERIn-Line Flow Type DH

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

36214.25

387

36214.25

15.25

15.25

387

10.97

11.66

INCH

DIN 2501250 DN 16

STAINLESS STEELCAST STEEL &

250 DN 10DIN 2501

MM

CAST IRON

ANSI class 300MM

INCHMM

ANSI class 125

ANSI class 250CAST IRON MM

INCH

INCH

28.8814.061.886.38 10.19 17.50357259162 48 445 733

12.75357

324

14.06

9.50241

259

1445.69162

301.1948

9.50241

10.191446.38

5.6930

1.88

1.19

406

44516.00

69927.50733

406NA17.50

NA 16.00699

28.88

27.50

23.12 1075 Lb.16 1.1216 29 587 488 Kg.

22.55

22.55

23.00

121216

25 573

291.00

584

1216

1257325

1.12

1.00

630

454 Kg.1000 Lb.466 Kg.

61324.84

24.15432 Kg.1025Lb.

950 Lb.

250, 150, 300 & DINFOR ANSI FLANGE CLASS

FLANGE SIZE A B C D E F G

EF

C .06 (1.5mm)D

TOP & BOTTOM FLANGES

(HOLES)H No.J

DIA. M R WEIGHTAPPROX.

H 10.00(254mm)

J

M

OUTLET

INLET

B

49.10

ACCESS CLEARANCE)

(1248 mm)

(MINIMUM SCREEN37.00

WAL

L

(624mm)24.55

(940mm) O-RING SEALEDOPENING,SCREEN INSP.4.50 (114mm)

C

SWAGE NIPPLE

FLUSH OUTLET2" NPT SOLIDS

(OPTIONAL BY REQUEST)

(OPTIONAL BY REQUEST)

279

29610.97279

11.66296

24.15613

24.84630

ANSI class 150CAST STEEL &

STAINLESS STEEL

4"THREADED DRAIN FLANGE

(STANDARD)

GR

15.00(381mm)

A

EXTERNALSCRAPER

ADJUSTMENT

35013.75

13.98355

INCHMM

MMINCH

28.8814.061.886.38 10.19 17.50357259162 48 445 733

12.75324

9.50241144

5.6930

1.19406

16.00699

27.50

23.12 1075 Lb.12 1.0212 26 587 488 Kg.

22.551212

22 573.87

454 Kg.1000 Lb.10.97

27911.66296

24.15613

24.84630

1/4 NPT ONLET GAUGE PORT

Page 36: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

34

TOP & BOTTOM FLANGES

SWAGE NIPPLE

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

250, 150, 300 & DINFOR ANSI FLANGE CLASS

10.75

10.75

11.50

11.50ANSI class 250 INCH 13.55 6.88

STAINLESS STEELCAST STEEL &ANSI class 300

MM 175

300 DN 16DIN 2501

DIN 2501300 DN 10

INCH

INCHMM

CAST IRON MM

6.88156

3446.12175

ANSI class 125

FLANGE SIZEINCH

CAST IRON MM12.80325

6.12156

A B

16.442.00 1.251620.50 33.25 17.75 24.00

84433.25806

31.75844

52141751292

417

38115.00

16.4432

2.00273

511.25

292

48320.50

52119.00

3216451 612

43217.75

1216

45117.00

1612

251.25

59824.12

321.00 23.55

609

31.75806

GENANA

1.2532273

DC

48319.00

F No.17.00432 12

12

H J

251.00 23.55

598

DIA.(HOLES) M

INLET

C .06 (1.5mm)

E

F

D

H

(690mm)27.16

B

OUTLET

(1380mm)

41.32(1049mm)

(MINIMUM SCREENACCESS CLEARANCE)

54.32

O-RING SEALED

SCREEN INSP.4.50 (114mm)

OPENING,

1450 Lb26.82

704 Kg

659 Kg

659 Kg1450 Lb

1550 Lb

681

APPROX.WEIGHT

1350 Lb614 Kg

26.07662

R

(305mm)12.00

J

M

C

FLUSH OUTLET2" NPT SOLIDS

(OPTIONAL BY REQUEST)

(OPTIONAL BY REQUEST)

12.80325

13.55344

26.07662

26.82681

ANSI class 150CAST STEEL &

STAINLESS STEEL

WAL

L

G

4" THREADEDDRAIN FLANGE(STANDARD)

R

A

15.00(381mm)

EXTERNAL SCRAPERADJUSTMENT

10.75

11.50MM 175

INCH

INCHMM

6.881566.12

84433.25806

31.75

52141751292

38115.00

16.4432

2.00273

1.25483

20.50

19.00

2612410 612

40016.14

1212

15.75 1222

1.02598

24.12

.87 23.55

704 Kg

659 Kg1450 Lb

1550 Lb

12.80325

13.55344

26.07662

26.82681

1/4 NPT ONLET GAUGE PORT

1/4 NPT ONLET GAUGE PORT

12" MANUAL STRAINERIn-Line Flow Type DH

Page 37: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

35

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

14" MANUAL STRAINERIn-Line Flow Type QH

CAST IRON

STAINLESS STEELCAST STEEL &ANSI class 150

ANSI class 125

FLANGE SIZE

29.44MM

INCHMM

748

7562475Lb1125 Kg

1034 Kg29.75

(356mm)

INCH

A

14.00

2275 Lb

APPROX.WEIGHT

TOP & BOTTOM FLANGES

(476mm)18.75

WAL

L

21.00(533mm)

(12) HOLES @ 1.12 DIA

O-RING SEALED

4.00 (102mm)SCREEN INSPECTION OPENING

FOR ANSI CLASS 150

16.25(413mm)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

15.2515.25(387mm) (387mm)

(25mm)1.00

12.31(313mm)

(MINIMUM SCREEN

(684mm)26.94

ACCESS CLEARANCE)(940mm)43.00

(344m)

SOLIDS FLUSH OUTLET2" NPT

13.53

(650mm)

A

25.59

1.38(35mm)

(1368mm)53.88

(OPTIONAL BY REQUEST)

SWAGE NIPPLE(OPTIONAL BY REQUEST)

4" THREADEDDRAIN FLANGE(STANDARD)

.06(1.5mm)

OUTLET

INLET

15.00(381mm)

1/4" NPTGAUGE PORT

Page 38: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

36

ANSI class 150CAST STEEL &

STAINLESS STEEL

FLANGE SIZEANSI class 125

CAST IRON

(27mm)

WAL

L

17.00(432mm)

1.06

(432mm)17.00

(384mm)15.12

ACCESS CLEARANCE)(MINIMUM SCREEN

(1054mm)41.50

29 (597mm)

TOP & BOTTOM FLANGES

AINCHMM

INCHMM

32.62829

32.28820

16.00(406mm)

2980LbWEIGHT

3210 Lb1350 Kg

1460 Kg

APPROX.

54021.25

SCREEN INSPECTION OPENING

SOLIDS FLUSH OUTLET2" NPT

(16) HOLES 1.12

A

23.50

O-RING SEALED

5.00 (127mm)

FOR ANSI CLASS 150

18.50(470mm)

1.44(37mm)

INLET

OUTLET

28.19(716mm)327mm)

14.61

(753mm)29.64

(1506mm)59.28

(OPTIONAL BY REQUEST)

(OPTIONAL BY REQUEST)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

SWAGE NIPPLE

.06(1.5mm)

1/4" NPTGAUGE PORT

(STANDARD)DRAIN FLANGE5" THREADED

16" MANUAL STRAINERIn-Line Flow Type QH

Page 39: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

37

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

20" MANUAL STRAINERIn-Line Flow Type HH

WAL

L

ANSI class 125CAST IRON

STAINLESS STEELCAST STEEL &ANSI class 150

MMINCH

MMINCH

SIZE

1960 Kg

3950 Lb

4309 Lb1790 Kg

39.501003

99339.09

A APPROX.WEIGHT

TOP & BOTTOM FLANGES

(483mm)

20.00(508mm)

INLET

27.50(699mm)

25.00(635mm)

18°

A

(483mm)19.00

15.00(381mm)

19.00

1.81(46mm)

5.00

(6 PLACES)SCREEN INSPECTION OPENING

60°

INLET GAUGE PORT PLUG1/4"-NPT

30°

(127mm)

A

16.40(417mm)

29.39(746.5mm)

ACCESS CLEARANCE)(MINIMUM SCREEN

(1092mm)43.00

(938.5mm)36.95

6.44(164mm)

OUTLET GAUGE PORT PLUG1/4"-NPT

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

(385mm)15.17

OUTLET

(35mm)1.38

SWAGE NIPPLE(OPTIONAL BY REQUEST)

SOLIDS FLUSH OUTLET(OPTIONAL BY REQUEST)

2" NPT

12 HOLES1.12 DIA

Page 40: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

38

FOUN

DRY

MARK

2 INCH

HELL

AN

ASTM A

278-

64 CL

ASS 30

U.S. P

ATENT N

o. RE

3556

0

HEAT

CODE

THREE WAY BALL VALVEPRESSURE SWITCH &

AS SHOWNINSTALLED BY CUST.SUPPLIED BY HELLAN

(200)7.89

(344)13.54

SCRE

EN R

EMO

VA

L

(423)16.64

OUTLET

MOTORIZED DRAIN VALVE

(366)14.41

(190)7.50

(229)

(337)13.27

9.03

INLET

(84)3.31Ø

5.0

25.0

10.0

20.0

15.0

SINGLE SWINCREASE

SET-PT

WALL

SOLIDS FLUSH OUTLET1" NPT

SCREEN DRIVE MOTOR(1/3 H.P.)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN.

VIEW A-A

A A

PSIDLO HI

EXTERNAL SCRAPERADJUSTMENT

1-1/2" NPTCAST IRON1-1/2" NPT

CAST STEEL and STAINLESS STEEL2" NPT

CAST IRON2" NPT

CAST STEEL and STAINLESS STEEL

THREAD SIZE

1-1/2"

2"

STRAINERSIZE

22 Kg49 Lb21 Kg

49 Lb22 Kg46 Lb

46 Lb21 Kg

APPROX.WEIGHT

1-1/2" & 2" AUTOMATIC STRAINERIn-Line Flow Type TSA

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

38

Page 41: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

39

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

39

2-1/2" & 3" AUTOMATIC STRAINERIn-Line Flow Type TSA

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

(1/3 H.P.)SCREEN DRIVE MOTOR

WALL

SOLIDS FLUSH OUTLET1-1/2" NPT

A-AVIEW

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.ORIENTATION - DRAIN MUST BE DOWN.

PSIDLO HI

9.94(252)

18.50

SCRE

EN R

EMO

VA

L

(470)

(391)15.06

4.62(117)

9.75(248)

14.41(366)

11.05(281)

15.23(387)

INLETOUTLET

MOTORIZED DRAIN VALVE

25.0

15.010.0

20.0

SET-PT

INCREASESINGLE SW

5.0

EXTERNAL SCRAPERADJUSTMENT SUPPLIED BY HELLAN

INSTALLED BY CUST.

PRESSURE SWITCH & THREE WAY BALL VALVE

AS SHOWN

A A

FOUN

DRY

MARK

2 INCH

HELL

AN

ASTM A

278-

64 CL

ASS 30

U.S. P

ATENT N

o. RE

3556

0

HEAT

CODE

2-1/2"

3"

STRAINERSIZE

APPROX.

84 Lb38 Kg

WEIGHT

40 Kg89 Lb

84 Lb38 Kg89 Lb40 Kg

2-1/2" NPTCAST IRON2-1/2" NPT

CAST STEEL and STAINLESS STEEL3" NPT

CAST IRON3" NPT

CAST STEEL and STAINLESS STEEL

THREAD SIZE

Page 42: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

40

PRESSURE SWITCHSUPPLIED BY HELLANINSTALLED BY CUST.AS SHOWN

FLANGE DRILLING (NUMBER AND SIZE OF HOLES AND BOLT CIRCLE)

ALL OTHER APPLICABLE DIMENSIONS ARE IN ACCORDANCE WITH ANSI STANDARDS ABOVE.IS IN ACCORDANCE WITH D.I.N. STANDARDS.

CAST IRONANSI class 150

ANSI class 125

CAST STEEL &

DIN 250180 DN 10

MM

MMINCH

INCH

360 14414.19356

14.001405.69

5.50

FLANGE SIZE A B

24

19.94

.75

74 Kg

69 Kg163 Lb

155 Lb

C APPROX.WEIGHT

CLASS 150FOR ANSI FLANGE TOP & SIDE

FLANGE

CUSTOMER PIPING

SUPPLIED BY C.G.C.INSTALLED BY CUST.AS SHOWN

STAINLESS STEEL

PSID

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

(127mm)5.00

(76mm)3.00

.06(1.5mm)

4 HOLES.75 DIA (19mm)

(152mm)6.00

6.86(174mm)

STRAIGHT NIPPLE

14.75(375mm)

A(191mm)

7.50

(191mm)7.50

B

THREE WAY BALL VALVE

LO HI

B

(MINIMUM CLEARANCE20.25FOR SCREEN REMOVAL)

13.15

SCREEN DRIVE MOTOR(1/3 H.P.)

3.75 (95mm) DIA.

O-RING SEALEDFLANGED INSPECTION OPENING

SOLIDS FLUSH OUTLET1-1/2" NPT

MOTORIZED DRAIN VALVE

C

C

INLET

OUT

LET

ORIENTATION - DRAIN MUST BE DOWN

(334mm)

(514mm)

WA

LL5.0

25.0

10.0

20.0

15.0

INCREASESINGLE SWSET-PT

3" AUTOMATIC STRAINERAngle Flow Type AA

Page 43: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

41

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

4" AUTOMATIC STRAINERIn-Line Flow Type DA

250, 150, 300 & DINFOR ANSI FLANGE CLASS

FE

TOP & BOTTOM FLANGES

(102mm)H 4.00

J

37.54(953mm)

(MINIMUM SCREENACCESS CLEARANCE)

18.77

B

(477m)

WAL

L (660mm)26.00

R

.06 (1.5mm)D

G

(375mm)

M

14.75

SCREEN DRIVE MOTOR (1/3 H.P.)

A

THREE WAY BALL VALVE

WITH FITTINGSDIFF. PRESSURE SWITCH

(303 mm)

MOTORIZED DRAIN VALVE

SWAGE NIPPLE

11.93

C

2" NPT SOLIDSFLUSH OUTLET

EXTERNAL SCRAPER ADJUSTMENT

10.0 15.0

5.0 20.0

25.0

OUTLET

INLET

PSID

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE A CB D E FINCH

INCH

INCH

INCH

DIN 2501100 DN 16

100 DN 10

ANSI class 300CAST STEEL &

STAINLESS STEEL

DIN 2501

ANSI class 250CAST IRON

CAST IRONANSI class 125

1686.60

MM6.31160114

4.50 6.9417632

1.25254

10.00

6.00

6.00

6.316.60 4.50

1606.29168MM

MM

160

1521064.19114

6.29160MM 152106

4.19

6.941.25 10.00176

1576.19

32

24.94

254

2299.00

NANA24

.942299.00

(HOLES)G H RM FLANGE SIZE

2-1/2" NPT

7.88200

16.62422

.8822

88 393

15.4714.10358 2" NPT

.8887.8816.622007.50

422

19140616.00

22

19.75

8

88

7.50191

16.00406

DIA..7519

No.88

15.4712.54

38515.16393318

35013.79

2" NPT

2" NPT

15.16385

16.41416

200 Lb90 Kg

190 Lb

82 Kg

86 Kg180 Lb

77 Kg170 LbWEIGHT

N DRAINJ APPROX.

ANSI class 150CAST STEEL &

STAINLESS STEEL

INCH

INCH

1686.60

MM6.31160114

4.50 6.9417632

1.25254

10.00

6.001606.29

MM 1521064.19

1576.19

24.94

2299.00

7.09180

16.62422

.7118

88 393

15.4714.10358 2" NPT

7.09180406

16.0018.71

88

38515.16

35013.79 2" NPT

200 Lb90 Kg

82 Kg180 Lb

Page 44: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

42

FLUSH OUTLET2" NPT SOLIDS

MOTORIZED DRAIN VALVE

(375mm)

TOP & BOTTOM FLANGES

B

WAL

L

THREE WAY BALL VALVE

.06 (1.5mm)

250, 150, 300 & DINFOR ANSI FLANGE CLASS

FE

INLET

D

H

A

R

G

O-RING SEALEDOPENING,SCREEN INSP.3.25 (82mm)

WITH FITTINGSDIFF. PRESSURE SWITCH

OUTLET

(1124 mm)

ACCESS CLEARANCE)31.00 (MINIMUM SCREEN

22.14(561 mm)

(787 mm)

44.28SCREEN DRIVE MOTOR (1/3 H.P.)

SWAGE NIPPLE

13.54(344mm)

6.00(152mm)

J

M

14.75

C

EXTERNALSCRAPER ADJUSTMENT

25.0

20.0

15.0

5.0

10.0

PSID

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE

CAST IRONANSI class 125

ANSI class 300

CAST IRONANSI class 250

DIN 2501150 DN 16DIN 2501

150 DN 10STAINLESS STEEL

CAST STEEL &

NANA

9.69246

9.692168.50

246INCH 9.23MM 234

INCH

INCH

INCH

8.79

9.23MM

MM 223

234

8.79MM 223

A

5.31135 192

7.56 1.4437

135

1244.88

5.31192

181

7.56

7.12

89

B3.50

181

C7.12

1.44

1.0037

25

1.0025

D E

20.88530

12.50318

10.62270

50820.00

53020.88

50820.00

27911.00

12.50318

27911.00

F

27010.62

2419.50

G

2419.50

H

19.001212

.8822 483 460

18.12

18.95

19.62

19.061212

88

22.88

22.88

(HOLES)

8

JNo.8

22.88DIA.

484

498 44917.68460

18.12481

M R

44917.68

455 Lb207 Kg2 1/2"

182 Kg400 LbWEIGHTAPPROX.

195 Kg430 Lb193Kg425 Lb

3"

2 1/2"

3" NPT

FLANGE SIZEDRAINN

ANSI class 150CAST STEEL &

STAINLESS STEEL

9.692168.50

246INCH 9.23MM 234

INCH 8.79MM 223

5.31135 192

7.56 1.4437

1244.88

1817.12 1.00

2520.88530

12.50318

9.45240

50820.00

27911.00

2409.45

19.0088

.8122 483 460

18.12

19.6288

18.71

498 44917.68

455 Lb207 Kg2 1/2"

195 Kg430 Lb3"

6" AUTOMATIC STRAINERIn-Line Flow Type DA

Page 45: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

43

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

8" AUTOMATIC STRAINERIn-Line Flow Type DA

36.00 (MINIMUM SCREEN(893mm)

B

H

TOP & BOTTOM FLANGES250, 150, 300 & DINFOR ANSI FLANGE CLASS

FE

(203mm)8.00

(356mm)

SCREEN DRIVE MOTOR (1/3 H.P.)

C .06 (1.5mm)D

ACCESS CLEARANCE)

(1274mm)

(637mm)25.08

50.16

R

G

A

4.50 (114mm)

O-RING SEALED

SCREEN INSP.OPENING,

WITH FITTINGS

M

J

(375mm)14.75

C

SWAGE NIPPLE

14.00

DIFF. PRESSURE SWITCH MOTORIZED DRAIN VALVE

FLUSH OUTLET2" NPT SOLIDS

INLET

PSID

OUTLET

THREE WAY BALL VALVE

EXTERNAL SCRAPER ADJUSTMENT

WAL

L

25.0

20.05.015.010.0

DIN 2501200 DN 10

DIN 2501200 DN 16

CAST IRONANSI class 250

ANSI class 125CAST IRON

STAINLESS STEELCAST STEEL &ANSI class 300

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

FLANGE SIZE

11.75298

11.75

13.00330

298

13.00330255

10.042429.54

MM

INCH

INCHMM

149 232

5.381375.88

8.622199.12

2429.54

25510.04

INCH

INCHMM

MM

A5.38 8.62137

1495.88

219

2329.12

B C

34313.50

15.0038141 303

11.94

10.621.1229

1.62270

635

24.00610

25.00

34313.50

38115.00

NA1.12

11.9429

411.62

NA

303

D E24.00610

63525.00

GF H

318 kg.700 lb.WEIGHT

341 kg.750 lb.

750 lb.

800 lb.364 kg.

341 kg.

APPROX.

21.56548

22.1256212 25

.88

1.00

8812

22

59223.32

22.82580

54821.56

55822.00

M.88

1.0088

1212

22

25

(HOLES)No.J

DIA.

23.32

22.82580

592

R

ANSI class 150CAST STEEL &

STAINLESS STEEL

11.61295

11.611295255

10.042429.54

MM

INCH

INCHMM

149 232

5.381375.88

8.622199.12

34313.50

15.0038141 303

11.94

10.621.1229

1.62270

635

24.00610

25.00

750 lb.

800 lb.364 kg.

341 kg.21.56548

22.1256212 22

.87

.87

8812

22

59223.32

22.82580

Page 46: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

44

B

(MINIMUM SCREEN

(1409 mm)

(705 mm)

ACCESS CLEARANCE)(1040 mm)

27.75

41.00

55.50WAL

L

R

G

A

4.50 (114mm)SCREEN INSP.OPENING,O-RING SEALED

DIFF. PRESSURE SWITCHWITH FITTINGS MOTORIZED DRAIN VALVE

SWAGE NIPPLE

SCREEN DRIVE MOTOR (1/3 H.P.)

(375mm)14.75

M

C

2" NPT SOLIDSFLUSH OUTLET

TOP & BOTTOM FLANGESFOR ANSI FLANGE CLASS

250, 150, 300 & DIN

FE H

(254mm)10.00

C .06 (1.5mm)D

J

OUTLET

INLET

14.72(374mm)

THREE WAY BALL VALVE

PSID

EXTERNAL SCRAPERADJUSTMENT

10.0 15.0

5.0 20.0

25.0

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

36214.25

387

36214.25

15.25

15.25

387

10.97

11.66

INCH

DIN 2501250 DN 16

STAINLESS STEELCAST STEEL &

250 DN 10DIN 2501

MM

CAST IRON

ANSI class 300MM

INCHMM

ANSI class 125

ANSI class 250CAST IRON MM

INCH

INCH

28.8814.061.886.38 10.19 17.50357259162 48 445 733

12.75357

324

14.06

9.50241

259

1445.69162

301.1948

9.50241

10.191446.38

5.6930

1.88

1.19

406

44516.00

69927.50733

406NA17.50

NA 16.00699

28.88

27.50

23.12 1075 Lb.16 1.1216 29 587 488 Kg.

22.55

22.55

23.00

121216

25 573

291.00

584

1216

1257325

1.12

1.00

630

454 Kg.1000 Lb.466 Kg.

61324.84

24.15432 Kg.1025Lb.

950 Lb.

FLANGE SIZE A B C D E F G (HOLES)H No.J

DIA. M R WEIGHTAPPROX.

279

29610.97279

11.66296

24.15613

24.84630

ANSI class 150CAST STEEL &

STAINLESS STEEL

35013.75

13.98355

INCHMM

MMINCH

28.8814.061.886.38 10.19 17.50357259162 48 445 733

12.75324

9.50241144

5.6930

1.19406

16.00699

27.50

23.12 1075 Lb.12 1.0212 26 587 488 Kg.

22.551212

22 573.87

454 Kg.1000 Lb.10.97

27911.66296

24.15613

24.84630

10" AUTOMATIC STRAINERIn-Line Flow Type DA

Page 47: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

45

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

12" AUTOMATIC STRAINERIn-Line Flow Type DA

WITH FITTINGSDIFF. PRESSURE SWITCH

(1140mm) ACCESS CLEARANCE)(MINIMUM SCREEN45.00

30.34(771mm)

B

R

A

4.50 (114mm)SCREEN INSP.OPENING,O-RING SEALED

MOTORIZED DRAIN VALVESWAGE NIPPLE

SCREEN DRIVE MOTOR (1/3 HP)

C

M

(375mm)

2" NPT SOLIDSFLUSH OUTLET

F

E

D

H

C .06 (1.5mm)

J

(305mm)12.00

FOR ANSI FLANGE CLASS250, 150, 300 & DIN TOP & BOTTOM FLANGES

G

(1541mm)60.68

OUTLET

INLET

(414mm)

WAL

L

10.0 15.0

5.0 20.0

25.0

14.75

16.29

THREE WAY BALL VALVE

PSID

EXTERNAL SCRAPERADJUSTMENT

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

10.75

10.75

11.50

11.50ANSI class 250 INCH 13.55 6.88

STAINLESS STEELCAST STEEL &ANSI class 300

MM 175

300 DN 16DIN 2501

DIN 2501300 DN 10

INCH

INCHMM

CAST IRON MM

6.88156

3446.12175

ANSI class 125

FLANGE SIZEINCH

CAST IRON MM12.80325

6.12156

A B

16.442.00 1.251620.50 33.25 17.75 24.00

84433.25806

31.75844

52141751292

417

38115.00

16.4432

2.00273

511.25

292

48320.50

52119.00

3216451 612

43217.75

1216

45117.00

1612

251.25

59824.12

321.00 23.55

609

31.75806

GENANA

1.2532273

DC

48319.00

F No.17.00432 12

12

H J

251.00 23.55

598

DIA.(HOLES) M

1450 Lb26.82

704 Kg

659 Kg

659 Kg1450 Lb

1550 Lb

681

APPROX.WEIGHT

1350 Lb614 Kg

26.07662

R

12.80325

13.55344

26.07662

26.82681

ANSI class 150CAST STEEL &

STAINLESS STEEL

10.75

11.50MM 175

INCH

INCHMM

6.881566.12

84433.25806

31.75

52141751292

38115.00

16.4432

2.00273

1.25483

20.50

19.00

2612410 612

40016.14

1212

15.75 1222

1.02598

24.12

.87 23.55

704 Kg

659 Kg1450 Lb

1550 Lb

12.80325

13.55344

26.07662

26.82681

Page 48: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

46

14" AUTOMATIC STRAINERIn-Line Flow Type QA

TOP & BOTTOM FLANGES

14.00(356mm)

18.75

(12) HOLES @ 1.12 DIA(533mm)

21.00

DIFF. PRESSURE SWITCHWITH FITTINGS SCREEN INSPECTION OPENING

4.00 (102mm)

O-RING SEALED

SCREEN DRIVE MOTORS (1/3 HP)

THREE WAY BALL VALVE

WAL

L

ANSI class 150CAST STEEL &

STAINLESS STEEL

FLANGE SIZE

CAST IRONANSI class 125

INCHMM

29.44748

INCHMM

A

75629.75

1818 Kg

1909 Kg4200 Lb

WEIGHTAPPROX.

4000 Lb

(476mm)

FOR ANSI CLASS 150

16.25(413mm)

10.0

5.0

25.0

15.0

20.0

PSID

(940mm) ACCESS CLEARANCE)

30.24(768mm)

(MINIMUM SCREEN43.00

(441mm)17.36

(596mm)23.47

A

(35mm)1.381.00

(25mm)

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

DRAIN VALVEMOTORIZED

INLET

OUTLET

SOLIDS FLUSH OUTLET2" NPT

(349mm)13.72

15.25(387mm)

15.25(387mm)

.06(1.5mm)

Page 49: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

47

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

14" AUTOMATIC STRAINERIn-Line Flow Type WSA

10.05.0

25.0

15.020.0IN

AIR VENT

SCREEN DRIVEMOTOR 1/2 HP

DIFFERENTIAL PRESSURE SWITCH AND GAUGE

1.00 DIA THRU (12) HOLEEQ. SP. ON A 18.75 B.C.(ANSI CLASS 150)

THREE WAY BALL VALVE

16.3

8

22.8

8

25.00

15.50

22.0

019

.50

39.3

128

.00

38.00

.88 DIA THRU (4) HOLESEQ. SP. ON A 28.00 B.C.

ACCESS FOR FUTURE BACKWASH INSTALLATION. INTERNAL BACKWASH COMPONENTS ARE OPPTIONAL BY REQUEST

.75 DIA THRU (4) HOLESEQ. SP. ON A 6.00 B.C.(ANSI CALSS 150)

DRAIN

CLEAN OUT ACCESS

LIFT POINT(2) PLACES

SCRAPER AND SCREENINSPECTION OPENING

89.5

0

PSID

INLET OUTLET

(MIN

IMU

M S

CRE

EN A

CC

ESS

CLE

AR

AN

CE)

PLU

S LI

FT R

IGG

ING

Weight – 1392 lb /633 kg

Page 50: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

48

16" AUTOMATIC STRAINERIn-Line Flow Type QA

WA

LL

48.00 (MINIMUM SCREENACCESS CLEARANCE)(1220mm) 33.13

(1683mm)66.26

1.44(37mm)

5.00 (127mm)

O-RING SEALEDSCREEN INSPECTION OPENING

19.84

(659mm)

(504mm)

25.95

32.62

(432mm)17.00 17.00

(432mm)

15.34(390mm)

2" NPTSOLIDS FLUSH OUTLET

DIFF. PRESSURE SWITCHWITH FITTINGS

SCREEN DRIVE MOTORS (1/3 HP)

1.06(27mm)

(406mm)16.00

(597mm)23.50

TOP & BOTTOM FLANGES

1.1229

21.25540

(842mm)

THREE WAY BALL VALVE

ANSI class 125

FLANGE SIZE

STAINLESS STEELCAST STEEL &ANSI class 150

MMINCH

CAST IRON MMINCH

2190 Kg

2090 Kg

82032.2882932.62

A

4830 Lb

WEIGHT4600 Lb

APPROX.

A

FOR ANSI CLASS 150

(470mm)18.50

5.0 20.0

25.0

10.0 15.0

SINGLE SWSET-PT

INCREASE

PSID

SWAGE NIPPLE

MOTORIZEDDRAIN VALVE

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

(1.5mm).06

INLET

OUTLET

Page 51: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

49

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

16" AUTOMATIC STRAINERIn-Line Flow Type SA

IN 10.05.0

25.0

15.020.0

AIR VENT

SCREEN DRIVEMOTOR 1/2 HP

1.00 DIA THRU (16) HOLEEQ. SP. ON A 21.25 B.C.(ANSI CLASS 150)

THREE WAY BALL VALVELIFT POINT(2) PLACES

SCRAPER AND SCRENINSPECTION OPENING

DIFFERENTIAL PRESSURE SWITCH AND GAUGE

CLEAN OUT ACCESS

DRAIN

.75 DIA THRU (4) HOLESEQ. SP. ON A 6.00 B.C.(ANSI CALSS 150)

22.8

8

16.3

8

28.00

18.50.88 DIA THRU (4) HOLESEQ. SP. ON A 32.00 B.C.

ACCESS FOR FUTURE BACKWASH INSTALLATION. INTERNAL BACKWASH COMPONENTS ARE OPPTIONAL BY REQUEST

25.3

819

.50

28.0

044

.94

44.00

98.5

0

INLET OUTLET

PSID

(MIN

IMU

M S

CRE

EN A

CC

ESS

CLE

AR

AN

CE)

PLU

S LI

FT R

IGG

ING

Weight – 1771 lb /805 kg

Page 52: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

50

1.12 DIA THRU (4) HOLESQE. SP. ON A 40.00 B.C.DRAIN

SCRAPER AND SCREEN INSPECTION OPENING

CLEAN OUT ACCESS ACCESS FOR FUTURE BACKWASHINSTALLATION. INTERNAL BACKWASH CONPONENTS ARE OPPTIONAL BY REQUEST

AIR VENT

LIFT POINT

MOTORIZED DRAIN VALVE

.75 DIA THRU (4) HOLESEQ. SP. ON A 6.00 B.C.

(ANSI CLASS 150)

1.25 DIA THRU (20) HOLEEQ. SP. ON A 25.00 B.C.(ANSI CLASS 150)

THREE WAY BALL VALVE

DIFFERENTIAL PRESSURE SWITCH AND GAUGE

SCREEN DRIVEMOTOR 1/2 HP

32.5021.50

28.2

5

23.2

5

8.00

2.25

23.0

025

.00

50.00

36.2

547

.00

IN20.0

15.0

25.0

5.010.0

CW

RO

T.M

TR.

NAMEPLATE

INLET OUTLET

PSID

CC

W R

OT.

MTR

.

110.

00PL

US

LIFT

RIG

GIN

G

(MIN

IMU

M S

CRE

EN A

CC

ESS

CLE

ARA

NC

E)

20" AUTOMATIC STRAINERIn-Line Flow Type WDA

Weight – 2750 lb /1250 kg

Page 53: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

51

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

20" AUTOMATIC STRAINERIn-Line Flow Type HA

(584mm)23.00

ANSI class 150CAST STEEL &

STAINLESS STEEL

FLANGE SIZE

CAST IRONANSI class 125

INCHMM

39.09993

INCHMM

A

100339.50

2588 Kg

13288 Kg6040 Lb

WEIGHTAPPROX.

5750 Lb

FOR ANSI CLASS 150

WAL

L

WITH FITTINGS

THREE WAY BALL VALVE

DIFF. PRESSURE SWITCH

SINGLE SWSET-PT

INCREASE

5.0 20.0

25.0

15.010.0

THESE DIMENSIONS ARE FOR REFERENCE ONLY. FOR INSTALLATION PURPOSES, REQUEST CERTIFIED DRAWINGS.

TOP & BOTTOM FLANGES

20.00(508mm)

1.38(35mm)

(544mm)21.44

.06(1.5mm)

19.00(483mm)

19.00(483mm)

DRAIN VALVEMOTORIZED

(20) HOLES @ 1.19 DIA

SOLIDS FLUSH OUTLET2" NPT

(390mm)15.34

(46mm)1.81

A

(691mm)27.20

25.00

27.50(699mm)

PSID

(MINIMUM SCREENACCESS CLEARANCE)(1270mm)

(896mm)35.29

50.00

SCREEN DRIVE MOTORS (1/3 HP)O-RING SEALED

SCREEN INSPECTION OPENING5.00 (127mm)

INLET

OUTLET

Page 54: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

14" AUTOMATIC STRAINERIn-Line Flow Type WDA

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

52

58.00

11.00

4.12

41.2

552

.75

29.8

830

.50

30.7

5

36.50

CLEAN OUT ACCESS

1.12 DIA THRU (4) HOLESQE. SP. ON A 48.00 B.C.

DRAIN

25.50

25.7

5

ACCESS FOR FUTURE BACKWASHINSTALLATION. INTERNAL BACKWASH CONPONENTS ARE OPPTIONAL BY REQUEST

.75 DIA THRU (4) HOLESEQ. SP. ON A 6.00 B.C.

(ANSI CLASS 150)

SCRAPER AND SCREENINSPECTION OPENING

DIFFERENTIAL PRESSURESWITCH AND GAUGE

THREE WAY BALL VALVE

MOTORIZED DRAIN VALVE

LIFT POINT

1.25 DIA THRU (20) HOLEEQ. SP. ON A 29.50 B.C.(ANSI CLASS 150)

AIR VENT

SCREEN DRIVEMOTOR 1/2 HP

IN

20.015.0

25.0

5.010.0

NAMEPLATE

CW

RO

T.M

TR.

CC

W R

OT.

MTR.

OUTLETINLET

PSID

(MIN

IMU

M S

CRE

EN A

CC

ESS

CLE

ARA

NC

E)12

5.00

PLU

S LI

FT R

IGG

ING

24" AUTOMATIC STRAINERIn-Line Flow Type WDA

Weight – 3590 lb /1632 kg

Page 55: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

53

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

30" AUTOMATIC STRAINERIn-Line Flow Type WDA

SCREEN DRIVEMOTOR 1/2 HP

DIFFERENTIAL PRESSURESWITCH AND GAUGE

.75 DIA THRU (4) HOLESEQ. SP. ON A 6.00 B.C.

(ANSI CLASS 150)

SCRAPER AND SCREENINSPECTION OPENING

CC

W R

OT.

MTR

.

10.05.0

25.0

15.020.0

MTR

.C

CW

RO

T.

MTR.

CC

W R

OT.

MTR

.C

CW

RO

T.

AIR VENT

THREE WAY BALL VALVE

1.38 DIA THRU (28) HOLEEQ. SP. ON A 36.00 B.C.(AWWA CLASS 125)

LIFT POINT

MOTORIZED DRAIN VALVE

CLEAN OUT ACCESS

DRAIN

1.12 DIA THRU (4) HOLESQE. SP. ON A 60.00 B.C.

ACCESS FOR FUTURE BACKWASHINSTALLATION. INTERNAL BACKWASH CONPONENTS ARE OPPTIONAL BY REQUEST

PSID

INLET OUTLET

33.00 44.00

45.7

5

36.7

5

35.2

537

.18

53.7

563

.16

12.50

76.00

153.

00PL

US

LIFT

RIG

GIN

G

(MIN

IMU

M S

CRE

EN A

CC

ESS

CLE

ARA

NC

E)

Weight – 5020 lb /7000 kg

Page 56: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

11⁄2" & 2" TSH/TSA AND 2" AH STRAINERClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

54

1 1.5 2 2.5 3(×10)

4 5 6 7 8 9100 1.5 2 2.5 3

(×100)4 5 6 7 8 9 1000

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

Page 57: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

55

11⁄2" & 2" TSH/TSA STRAINERClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 58: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

3" DH STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

56

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 59: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

57

2-1/2" AH STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 60: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

21⁄2" & 3" TSH/TSA AND 3" AH/AA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

58

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 61: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

59

21⁄2" & 3" TSH/TSA AND 3" AH/AA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 62: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

4" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

60

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 63: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 9100 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

200100 300 500 600 700 800400 100050 60 70 8040 1500 2000 3000 3800Water Flow Rate, Liters Per Minute**

(×10)(×100)

1000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

61

4" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 64: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

6" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

62

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 65: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

63

6" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 66: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

8" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

64

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 67: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

65

8" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 68: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

10" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

66

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 69: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

67

10" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 70: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

12" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

68

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.51/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 71: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

69

12" DH/DA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 72: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

14" QH/QA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

70

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 73: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 91000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.002" Wedge-Wire

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×100)(×1000)

10,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

71

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

14" QH/QA STRAINERSClean Pressure Drop vs. Flow Rate

Page 74: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

14"& 16" SA/WDA AND 16" QH/QA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

72

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

rP

russer

D eI

SP ,

po

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

rP

ru sser

D e* sra

B ,p

o

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 75: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

rP

russer

D eI

SP ,

po

1098

7

6

5

4

3

2.5

2

1.5

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

.70

rP

ru sser

D e* sra

B ,p

o

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

20001000 3000 6000 80004000 10000500 600 800400 15000 20000 30000 38000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

73

14"& 16" SA/WDA AND 16" QH/QA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 76: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

20" HH/AH AND 20" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

74

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 77: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

75

20" HH/AH AND 20" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 78: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

24" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

76

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 79: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

77

24" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 80: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

30" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

78

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

1/4, 3/16" Scr. Perf.

1/8" Scr. Perf.

1/16, 1/32" Scr. Perf.

3/32" Scr. Perf.

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

Page 81: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

1 1.5 2 2.5 3 4 5 6 7 8 910,000 1.5 2 2.5 3 4 5 6 7 8 9

Water Flow Rate GPM

Pre

ssur

e D

rop

, PS

I

1098

7

6

5

4

3

2.5

2

1.5

.70

Pre

ssur

e D

rop

, Bar

s*

.60

.50

.40

.35

.30

.25

.20

.15

.10

.070

.060

.050

.040

.030

.025

.020

.015

.010

.007

2000010000 30000 60000 8000040000 1000006000 80004000 150000 200000 300000 380000Water Flow Rate, Liters Per Minute**

.015" Wedge-Wire

.009" Wedge-Wire

.007" Wedge-Wire

.005" Wedge-Wire

.004" Wedge-Wire

(×1000)(×10,000)

100,000

1.9.8

.7

.6

.5

.4

.3

.25

.2

.15

.1

79

30" WDA STRAINERSClean Pressure Drop vs. Flow Rate

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 82: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

80

SPECIFYING A MODEL NUMBER

CHART A – STRAINER SIZE

Flow Rate Pipe Part No. (GPM) Size Code

95 1-1/2" 015

95 2" 020

160 2-1/2" 025

235 3" 030

360 4" 040

880 6" 060

1450 8" 080

2075 10" 100

2750 12" 120

4100 14" 140

5300 16" 160

8250 20" 200

10650 24" 240

16650 30" 300

(See page 11-12 for information on selecting size.)

CHART B – FLANGE TYPE

Flange Available Part No. Type Materials Code

Class 125 Flat Face Cast Iron 1

Class 250 Raised Face Cast iron 2

Class 150 Steel, Stainless Steel and Bronze 3

Class 300 Raised Face Steel, Stainless Steel and Bronze 4

Class 125LW Carbon Steel Weldment SW

Note: Contact the factory for information on flange types not listed above.

(See page 14 for information on flange selection.)

CHART C – BODY STYLE

Body Part No. Style CodeAngled Flow, Single Screen A

In-Line Flow, Dual Screens D

In-Line Flow, Quad Screens Q

In-Line Flow, Six Screens H

(See pages 8-10 for information on availability of strainersin various types of operation methods.)

CHART D – METHOD OF OPERATION

Method of Part No. Operation Code

Manual (Handwheel) H

Automatic A

Note: Strainers with motorized option must be ordered with appropriate control panel.

See information on specifying control panel below.

(See pages 8-10 for information on availability of strainersin various types of operation methods.)

CHART E – MOTOR SPECIFICATIONS FORAUTOMATIC STRAINERS

(For Manual Strainers, enter a “-” in this portion)

Motor Part No. Option Code

230/460 VAC 50/60HZ, 3PH, TEFC 1

115/230 VAC 50/60HZ, 1PH, TEFC 2

230/460 VAC 50/60HZ, 3PH, NEMA 7 3

115/230 VAC 50/60HZ, 1PH, NEMA 7 4

Note: Contact the factory for information on motor options not listed above.

CHART F – SCREEN MATERIAL

Screen Part No. Material Code

Monel Screen, All Parts 6

316 Screen, Cast Iron Hub, Cast Iron Center Ring, Bronze End Ring 4

316 Stainless Steel, All Parts 5

Note: Contact the factory for information on screen materials not listed above.

A model number for a Hellan Strainer may be specified by utilizing the charts and information below:

SAMPLE MODEL NUMBER

0 8 0 1 D H - 4 0 4 0 0

Basic Construction Materials (Chart H)Screen Opening Size (Chart G)Screen Material (Chart F)Motor Type (Chart E)Operation (Chart D)Body Style (Chart C)Flange Type (Chart B)Size (Chart A)

Page 83: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

81

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

AUTOMATIC STRAINER CONTROLPanel Part Number

CHART G – SCREEN OPENING SIZE OPTIONS

Screen Opening Part No. Size Code

Perforated Screen Options

1/32" 02

1/16" 04

3/32" 06

1/8" 08

3/16" 12

1/4" 16

Slot Width Part No. Size Code

Wedge-Wire Screen Options

.004" A4

.005" A5

.007" A7

.009" A9

.015" B5

(See page 11 for information on screen opening options.)

CHART H – BODY MATERIAL OPTIONS

Body Part No. Material Code

Cast Iron, ASTM A278 Class 30 00

Bronze, C-95800 01

Cast Stainless Steel, ASTM A351 CF8M 04

Cast Steel, ASTM A216 WCB 07

Carbon Steel, Weldment, ASTM A36 10

Note: Contact the factory for body material options and coatings and finishes not listed above.

(See page 14 for information on body material options.)

When ordering an automatic strainer, an appropriate control panel must also be ordered. Use the chart below to specify an appropriate part number for the control panel.

SAMPLE CONTROL PANEL PART NUMBER

S S P - C 2 D

Enclosure (Chart 3)Number of Motors (Chart 2)Voltage (Chart 1)

CHART 1 – CONTROL PANEL VOLTAGE OPTIONS

Control Panel Part No. Voltage Code

460 VAC 50/60 HZ, 3 PH A

230 VAC 50/60 HZ, 3 PH B

115 VAC 50/60 HZ, 1 PH C

Note: Contact the factory for information on control panel voltages not listed above.

CHART 2 – NUMBER OF MOTORSFOR CONTROL PANEL

Number of Part No. Motors Code

1 or 2 Motors 2

4 Motors 4

6 Motors 6

CHART 3 – CONTROL PANELENCLOSURE OPTIONS

Enclosure Part No. Type Code

NEMA 4X Polycarbonate D

NEMA 4X Stailess Steel C

Note: Contact the factory for control panel enclosure options not listed above.

Page 84: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

SAMPLES OF STANDARD SPECIFICATION

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

82

HELLAN MANUAL STRAINERS

The strainer shall be a _____" manual type employing _____cylindrical straining screens of the peripheral inflow design.The straining screens shall have _____" round perforations orwedgewire _____" slots and be of Type 316 Stainless Steelmaterial. Adjustable rigid scraper bars or brushes shall bemounted adjacent to the screens to accommodate scrapping of accumulated solids from the screens when the strainingscreens are rotated by means of a handwheel during a cleaningcycle. Removal of an inspection cover shall give access to thescraper bar or brush for inspection and adjustment and shallnot require the disassembly of the strainer to accomplish those tasks.

The strainer shall also have a sump for storage of strainedsolids. A flush valve installed on the sump by others shall beused to flush solids from the strainer during cleaning cycles.

The strainer body shall be of cast or fabricated steel ASTM _____ and have integral, in-line _____" inlet, and outlet flanges. Flanges shall be ANSI class _____.

The assembled strainer shall be hydrostatically pressure testedto 1-1/2" times the maximum allowable working pressure for aperiod of 10 minutes.

The assembled strainer shall be painted with a high-qualityalkyd machinery enamel (gray color), Glidden Glid-GuardAlkyd Industrial Enamel No. 4550 Series.

An adjustable pressure differential switch (optional) shall bemounted on the strainer and shall be used to initiate an alarmif the pressure drop reaches a predetermined set point.

The strainer shall be a Hellan Strainer manufactured by TheHellan Strainer Company, Cleveland, Ohio.

HELLAN AUTOMATIC STRAINERS

The strainer shall be a _____" automatic type employing_____ cylindrical straining screens of the peripheral inflowdesign. The straining screens shall have _____" round per -forations or wedgewire _____" slots and be of Type 316Stainless Steel material. Adjustable rigid scraper bars or brushes shall be mounted adjacent to the screens to accom -modate scraping of accumulated solids from the screens whenthe straining screens are rotated with an electric motor andsuitable gear reduction. Each motor shall be 1/3 to 2 horse-power (as required) _____ Volt, _____ Ph, _____ Hz, 1.15 SFClass “F” Insulation, TEFC, 56C-Face, Footless. Removal of aninspection cover shall give access to the scraper bar or brushfor inspection and adjustment and shall not require the disassembly of the strainer to accomplish those tasks.

The strainer shall also have a sump for storage of strainedsolids. One 1-1/4" ball valve on 1-1/2" & 2" strainers, one 1-1/2" ball valve on 2-1/2" & 3" strainers, two 2" ball valves on14" and 16" strainers, two 3" ball valves on 20" and 24" strainers and two 4” ball valves on 30" and 36" strainers.

The strainer body shall be of cast or fabricated _____ con-struction per ASTM _____ and have integral, in-line _____"inlet, and outlet flanges. Flanges shall be ANSI class _____.

The assembled strainer shall be hydrostatically pressure testedto 1-1/2 times the maximum allowable working pressure for aperiod of 10 minutes.

The assembled (cast construction) strainer shall be paintedwith a high-quality alkyd machinery enamel (gray color),Glidden Glid-Guard Alkyd Industrial Enamel No. 4550 Series.Assembled strainer of fabricated construction will be paintedwith a high-quality machinery gray, Glidden No. 4208 Series.

An electric control panel furnished by The Hellan StrainerCompany shall control the strainer cleaning cycle. The panelshall include all motor starters, control relays, fuse and over-load protection, control transformer, operation lights, etc., andshall be mounted in a NEMA 4X wall mounted polycarbonateenclosure equipped with a door disconnect switch. The controlpanel shall conform to current NEMA, NEC, and OSHA codesand regulations.

The strainer control panel shall be equipped with a pro -grammable solid state timer to initiate cleaning cycles at predetermined intervals, a hand/off/automatic selector switch,and a push-button for manual starting. An adjustable cycleduration timer shall also be furnished to allow for control ofthe cleaning cycle duration. An adjustable pressure differentialswitch shall be mounted on the strainer and shall be used toinitiate a cleaning cycle if the pressure drop reaches a predetermined set point.

The strainer shall be a Hellan Strainer manufactured by The Hellan Strainer Company, Cleveland, Ohio.

For assistance in selecting a strainer, or specifying a model, contact the Hellan sales department at 1-888-4-HELLAN.

Page 85: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

83

NOTES

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

Page 86: Hellan Strainer Benefits 1 Quality Assurance and Product Testing 2 · 2015-08-26 · QUALITY ASSURANCE AND TESTING TESTING CLEVELAND, OHIO USA PHONE (216) 206-4200 † FAX (216) 206-4242

CLEVELAND, OHIO USAPHONE (216) 206-4200 • FAX (216) 206-4242

The Hellan Strainer Company

A Subsidiary of Industrial Manufacturing Company LLC

3249 East 80th Street

Cleveland, Ohio 44104 (USA)

Phone: 216/206-4200

Fax: 216/206-4242

Toll Free: 888-4-HELLAN

Web: www.hellanstrainer.com

Manufactured with quality in the United States

Protected under U.S. Patent

Printed in the United States