  • 96 58

    AB

    C

    9696A

    262

    240328

    40

    JN15-12/24(40.5) Indoor AC High Voltage Earthing Switch

    Outline dimension

    1. Advanced design and steady performance.

    2. Simple structures, simple mounting and adjustment.3. Quick breaking and making capability.4. Handsome appearance and delicate manufacture technics.

    5. Usable and scientific, available operation on both two sides(right and left).

    Product feature

    Technical specification

    Item Data UnitkVkAs

    kAkAmm

    kV

    40.531.5

    48080

    350 385 46095

    185

    Rated voltageRated short-time withstand currentRated short-circuit durationRated short-circuit making currentRated peak withstand currentCentral distance between poles

    1231.5, 40, 50

    480, 100, 12580, 100, 125

    150, 165, 210, 230, 250, 27542/4975/85

    1min. PF withstand voltageLightning impulse withstand voltage

    Rated insulting level

    JN15-12 indoor HV earthing switch absorbs advanced new technics from

    domestic and abroad. It conforms to GB1985 AC HV disconnect switch and earth

    switch, relative standards IEC62271-102 and passes KEMA test. The apparatus

    applies to power system of rating below12/24/40.5kV, and AC 50/60H z. It is

    suitable for various types HV switchgear for earthing protection. The holisti c

    earthing switch consists of basis, supporting insulator, main axis, main blade,

    fast spring, fixed and moving contact. Additional electronic display is also

    available according to the user's requirement.

    Summary

    1. Altitude: 1000m;

    2. Ambient temperature: -25 ~+40 ;

    3. Relative humidity: daily average 95 , monthly average 90 ;

    4. Earthquake intensity: 8 degree.

    Ambient condition

    2431.5, 40, 50

    480, 100, 12580, 100, 125

    210, 230, 250, 27550/60

    125/145

    45

    40240325

    339

    6-9x1996 96 96

    250

    596674

    250

    A

    A

    A-A

    JN15-12/40 Earthing switch

    96250 250

    596674

    96 96

    Model A CB

    296

    58

    240333

    40

    A-A

    JN15-12/40-210JN15-12/40-230JN15-12/40-250JN15-12/40-275

    210

    230

    250

    275

    516

    556

    596

    646

    655

    710

    760

    810

    96

    JN15-12/31.5 Earthing switch

    A CBModel 535565655710760810

    150165210230250275

    396426516556596646

    JN15-12/31.5-150JN15-12/31.5-165JN15-12/31.5-210JN15-12/31.5-230JN15-12/31.5-250JN15-12/31.5-275

    A

    96

    6-9 19

    A

    240

    Mounting hole

    300

    350

    385

    460

    724

    824

    894

    1044

    855

    955

    1025

    1175

    JN15-40.5/31.5-300JN15-40.5/31.5-350JN15-40.5/31.5-385JN15-40.5/31.5-460

    Mounting hole

    Model A CB

    96

    96A

    BC

    96A

    96

    250

    518

    25

    A

    250362

    40

    14-919

    A

    96 96

    JN15-40.5/31.5 Earthing switch

    JN15-24/40 Earthing switch

    47 48

  • 96 58

    AB

    C

    9696A

    262

    240328

    40

    JN15-12/24(40.5) Indoor AC High Voltage Earthing Switch

    Outline dimension

    1. Advanced design and steady performance.

    2. Simple structures, simple mounting and adjustment.3. Quick breaking and making capability.4. Handsome appearance and delicate manufacture technics.

    5. Usable and scientific, available operation on both two sides(right and left).

    Product feature

    Technical specification

    Item Data UnitkVkAs

    kAkAmm

    kV

    40.531.5

    48080

    350 385 46095

    185

    Rated voltageRated short-time withstand currentRated short-circuit durationRated short-circuit making currentRated peak withstand currentCentral distance between poles

    1231.5, 40, 50

    480, 100, 12580, 100, 125

    150, 165, 210, 230, 250, 27542/4975/85

    1min. PF withstand voltageLightning impulse withstand voltage

    Rated insulting level

    JN15-12 indoor HV earthing switch absorbs advanced new technics from

    domestic and abroad. It conforms to GB1985 AC HV disconnect switch and earth

    switch, relative standards IEC62271-102 and passes KEMA test. The apparatus

    applies to power system of rating below12/24/40.5kV, and AC 50/60H z. It is

    suitable for various types HV switchgear for earthing protection. The holisti c

    earthing switch consists of basis, supporting insulator, main axis, main blade,

    fast spring, fixed and moving contact. Additional electronic display is also

    available according to the user's requirement.

    Summary

    1. Altitude: 1000m;

    2. Ambient temperature: -25 ~+40 ;

    3. Relative humidity: daily average 95 , monthly average 90 ;

    4. Earthquake intensity: 8 degree.

    Ambient condition

    2431.5, 40, 50

    480, 100, 12580, 100, 125

    210, 230, 250, 27550/60

    125/145

    45

    40240325

    339

    6-9x1996 96 96

    250

    596674

    250

    A

    A

    A-A

    JN15-12/40 Earthing switch

    96250 250

    596674

    96 96

    Model A CB

    296

    58

    240333

    40

    A-A

    JN15-12/40-210JN15-12/40-230JN15-12/40-250JN15-12/40-275

    210

    230

    250

    275

    516

    556

    596

    646

    655

    710

    760

    810

    96

    JN15-12/31.5 Earthing switch

    A CBModel 535565655710760810

    150165210230250275

    396426516556596646

    JN15-12/31.5-150JN15-12/31.5-165JN15-12/31.5-210JN15-12/31.5-230JN15-12/31.5-250JN15-12/31.5-275

    A

    96

    6-9 19

    A

    240

    Mounting hole

    300

    350

    385

    460

    724

    824

    894

    1044

    855

    955

    1025

    1175

    JN15-40.5/31.5-300JN15-40.5/31.5-350JN15-40.5/31.5-385JN15-40.5/31.5-460

    Mounting hole

    Model A CB

    96

    96A

    BC

    96A

    96

    250

    518

    25

    A

    250362

    40

    14-919

    A

    96 96

    JN15-40.5/31.5 Earthing switch

    JN15-24/40 Earthing switch

    47 48

    - 56.pdf- 57.pdf