HBD Update. Itzhak Tserruya DC meeting, May 7, 2008. HBD status and plans. HBD west is closed inside the glove box with CF 4 in recirculation mode through the LEGS gas system. - PowerPoint PPT Presentation

Citation preview

Page 1: HBD Update

1

HBD Update

Itzhak Tserruya

DC meeting, May 7, 2008

May7, 2008

Page 2: HBD Update

2

HBD status and plans

HBD west is closed inside the glove box with CF4 in recirculation mode through the LEGS gas system.

- We did not install the light cube and the large shades as originally planned. Better design will be done for the East arm.

- All 30 GEMs were tested up to 400 V prior of closing the detector. 29 passed the test, one GEM (WN1 – bottom) was found with a dead short even before applying HV.

- The HBD was closed inside the glove box a few days ago, with N2 flow in recirculation mode at a flow of 2 lpm.

- Initial reading of 22 ppm water, dropped to 17.4 ppm within 1h and to 11 ppm overnight.

- Shift to CF4 on Tuesday morning

- LEGS system is working very stably. Glove box is at 4T overpressure wrt to outside pressure, LEGS gas system is running at 1T overpressure wrt to glove box.

- HV tests to start on ThursdayMay7, 2008

Page 3: HBD Update

3

HBD background rejection in run-7

May7, 2008

Page 4: HBD Update

May7, 2008 4

Data selection and electron ID EWG nanoDST files, 331 runs, there are

only 49 runs left. Vertex cut: +/- 20 cm. Centrality > 50%. 1682.7M events before vertex cut 1194.1M events after vertex 546.2M events after centrality cut.

DC quality cut: 31 or 63. 3σ matching cuts on Δφ and Δz to EMC. RICH: n0>2, 2/npe<10, disp<5. EMC: 0.6 < E/p < 1.2.

For pairing modified PairObj has been used.

Then PairAnalysis to analyse the pairs and fill N-tuple.

Page 5: HBD Update

May7, 2008 5

Rejection step 0: fully reconstructed conversions

This rejection is done using the well known phiV (orientation angle of the pair in the magnetic field) cut.

The phiV distribution in Run-7 looks different (it is much broader) than in Run-4 presumably due to multiple scattering in the HBD (resolution of the phiV becomes worse) and different magnetic field.

Usually a phiV cut of <0.14 || > 3.0 (depending on the magnetic field polarity) is used.

Here we use the same cuts although they remove only a fraction of the conversions because (i) if we use a stronger cut (as this plot suggests) we will significantly cut fully reconstructed Dalitz pairs which are part of our signal and (ii) the HBD removes these conversions as will be shown later.

Page 6: HBD Update

May7, 2008 6

Rejection step I: matching to the HBD

Step I is just 3σ cut on the matching distributions between the DC track projections and the closest cluster in the HBD.

Matching cuts to HBD: |Δφ|<0.05 rad and |ΔZ|<4.0 cm.

Page 7: HBD Update

May7, 2008 7

Conversions

There are three main sources of conversions: beam pipe (~0.3%), CF4

gas (~0.6%) and backplane of the HBD (~2.5%).

The soft phiV cut <0.14 || >3.0 of step 0 removes only part of the conversions. The remaining conversions are removed by the matching cuts to the HBD (step I).

Page 8: HBD Update

May7, 2008 8

Single vs double e response

Select pairs with m<0.15 GeV/c2 . Divide them into two

classes: V-pairs and open pairs, both are Dalitz pairs.

The 1st row plots are for the V-pairs.

The 2nd row plots are for the open pairs.

Cut on 150 ADC counts to separate singles from doubles.

Page 9: HBD Update

May7, 2008 9

Rejection step II: double cluster in HBD

If one of the tracks is matched to a double HBD cluster the track (pair) is removed from the list.

Definition for a double cluster: pulse height A>150 ADC counts.

This step rejects a significant fraction of the combinatorial background originating from conversions and Dalitz pairs. It works both for the fully and partially reconstructed conversions and Dalitz pairs.

Page 10: HBD Update

May7, 2008 10

Rejection step III: conversions in CF4

There is still a remaining fraction of tracks that originate from conversions in the CF4 gas but create a single cluster. This happens when the photon converts approximately in the second half of the radiator, towards the GEM detectors.

Pairs with a V pattern and single cluster are rejected as fully reconstructed conversions originating in the CF4 gas.

Page 11: HBD Update

May7, 2008 11

Rejection step IV: close hit cut

If the HBD cluster associated to a central arm electron has a close hit that does not belong to any track, the central arm electron is rejected.

Close hit definition:

- distance < 10 cm (~200 mrad)

- # of pads/cluster > 1

- charge < 100 ADC

Page 12: HBD Update

May7, 2008 12

Results of the rejection steps

The 1st row is the mass spectrum after step 0 (conversions rejection with soft phiV cut).

The 2nd row is the spectrum after step I (3σ matching cuts to HBD).

The 3rd row is after step II, (rejection of conversions cutting on the doubles).

The 4th row is after step III (rejection of photon conversions in the CF4 gas) .

The 5th row is the final result after step IV (close hit cut).

Red: unlike, same eventBlue: unlike, mixed events

Subtracted

Combined amplitude-size cut is not yet implemented. It was successfully used in HBD PISA simulations using HIJING events.

Page 13: HBD Update

May7, 2008 13

Before and after

Step 0

Step IV

Signal

Page 14: HBD Update

May7, 2008 14

Let’s look at the numbers Step 0: m>0.15 GeV/c2, S=929 +/- 223 S/B=0.04 m<0.15 GeV/c2, S=187220 +/- 460, S/B=15.2 Step I: m>0.15 GeV/c2, S=232 +/- 90, S/B=0.06 m<0.15 GeV/c2, S=87977 +/- 304, S/B=40.1 Step II: m>0.15 GeV/c2, S=431 +/- 59, S/B=0.28 m<0.15 GeV/c2, S=87338 +/- 298, S/B=104.4 Step III: m>0.15 GeV/c2, S=523 +/- 55, S/B=0.42 m<0.15 GeV/c2, S=87333 +/- 298, S/B=128.5 Step IV: m>0.15 GeV/c2, S=519 +/- 43, S/B=0.80 m<0.15 GeV/c2, S=86887 +/- 296, S/B=242.9

Seff increased from ~17 after step 0 to 148 after step IV.