Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Hazardous
Locations Light
Products and solutions will
Protect your business ...
A Series
E Series F Series
I Series D2 Series
S Series T Series
C Series
G Series
EXIT K Series
D Series
H Series
P Series
IO 1Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number --PT-40W AYZDA 40 4000K-5700K
PT-SOW AYZDA 50 4000K-5700K
PT-60W AYZDA 60 4000K-5700K
PT-70WAYZDA 70 4000K-5700K
PT-BOW AYZDA 80 4000K-5700K
PT-90W AYZDA 90 4000K-5700K
PT-1 OOW AYZDA 100 4000K-5700K
PT-110WAYZDA 110 4000K-5700K
PT-120W AYZDA 120 4000K-5700K
Voltage Lumens
AC 100-277V or AC200-480V 5600
AC 100-277V or AC200-480V 7000
AC 100-277V or AC200-480V 8400
AC 100-277V or AC200-480V 9800
AC 100-277V or AC200-480V 11200
AC 100-277V or AC200-480V 12600
AC 100-277V or AC200-480V 14000
AC100-277V 15400
AC100-277V 16800
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
70
"A"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40' ,60' ,90', 100', 11 O', 120'
Mechanical Information
AC200-480V models
Structure Diagram
Size (in}
12.6x9.4x6.5
12.6x9.4x6.5
OJ Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(120W)
1,81 t.85
3.82 , ...
6.24 , ...
7.65 7.39
'"
'·"
19.47 19.08
Distance[m] Pyrami1 Diamele (ml
-CO-Cl80(Halfdlvergenceangle:106.8") -c90-C270(Halfdivergeoc1an,g1&:109.4G)
041
E(O") 14'74 E(CiO) 54.7" !SIO E(CO) 53.�0
E(0°)
E(C90) 54.7°
E(CO) 53.4°
E(0°)
E(C�O) 5'1.7"
E(CO} 53A0
E(O") 1841
!(C90) 54.7° 151
E(CO) 53,4° J(,t
!(0°) 967 E(C90) S�.7° 94
E(COJ 53.�' 101
E(O")
E(C90) 54.7° 31 E(CO) 53.4' 29
illuminance[bt]
Plane illuminance curve
@]
cd/m2 -g=SS.O--g 6s.o•-y=7S.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
Ceiling mounting
Wall mounting
O 5 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number --20 4000K-5700K
30 4000K-5700K
40 4000K-5700K
50 4000K-5700K
60 4000K-5700K
70 4000K-5700K
PT-20W BYZDA
PT-30W BYZDA
PT-40W BYZDA
PT-SOW BYZDA
PT-60W BYZDA
PT-70W BYZDA
PT-BOW BYZDA 80 4000K-5700K
Voltage Lumens
AC 100-277V or AC200-480V 2800
AC 100-277V or AC200-480V 4200
AC 100-277V or AC200-480V 5600
AC 100-277V or AC200-480V 7000
AC 100-277V or AC200-480V 8400
AC100-277V 9800
AC100-277V 11200
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
-70
70
70
70
70
70
70
"B"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40 °
,60°
,90°
, 100°
, 110°
, 120°
Mechanical Information
AC200-480V models
Structure Diagram
Size (in)
¢ 10.6x6.5
¢ 10.6x6.5
O 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(SOW)
1.0 1.87
Distance[m] PyramisDiamete [ml
-CO-CIS0(Halfdivergenceangla:111.4•)
osl
!(0•)
E(CO)
E(0°)
E(CO)
E(0°)
E(CO)
E(O"l
E(CO)
E(O"]
E(CO)
m
"
E(O") �112
E(CO) �5
illuminancellxl
Plane illuminance curve
cd/m 2
-g-ss.o•-g-6s.o•-g-1s.o•
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Family Tree of Installation
25 ° Pole Stanchion Pole Stanchion � �9 Wall Arm
�r-:;: + �E���a�I�
I I
Guard
Dome Reflector
Adaptor Conduit
25 ° Pole Stanchion 3/4" or 1"
Pole Stanchion 3/4" or 1"
Wall Arm 3/4" or 1"
Ex-Box
+
Pendant Pole
Cemog Bcacket
r � Peodaot Pole
LS � �
I I
Luminiare Body
Angle Reflector
Catalog No.
25 DPS
PS
WA
Ceiling Bracket Expand Screw CB
Pendant Pole Use Ex-Box pp
12° Pendant Pole 3/4" or 1" 12 DPP
Ex-Box 3/4" EB
09 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L 70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number --60 4000K-5700K
80 4000K-5700K
100 4000K-5700K
120 4000K-5700K
150 4000K-5700K
180 4000K-5700K
200 4000K-5700K
220 4000K-5700K
PT-60W CYZDA
PT-SOW CYZDA
PT-lOOW CYZDA
PT-120W CYZDA
PT-lSOW CYZDA
PT-180W CYZDA
PT-200W CYZDA
PT-220W CYZDA
PT-240W CYZDA 240 4000K-5700K
Voltage Lumens
AC 1 00-277V or AC200-480V 8400
AC 1 00-277V or AC200-480V 11200
AC100-277V or AC200-480V 14000
AC100-277V or AC200-480V 16800
AC100-277V or AC200-480V 21000
AC 1 00-277V or AC200-480V 25200
AC100-277V or AC200-480V 28000
AC100-277V or AC200-480V 30800
AC100-277V or AC200-480V 33600
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
70
"C"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40' ,60' ,90', 100', 11 0', 120'
Mechanical Information
AC200-480V models
Structure Diagram
Size (in)
� 16x12.7
� 16x12.7
11 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(240W)
,, 1.91
Olstance[m] Pyramls Olamete (m)
-C0-C180(Halfdivergenceangle:113.8")
E(O•J E(COJ
E(O") E(CO)
E(O•) E(CO)
"'"
""
E(O•) ll29 E{CO) 56.9° 301
E(Q•J E(CO)
E(0°) E(CO)
,.,
"
lllumlnance(lx)
Plane illuminance curve
cd/m i
-g-SS.O"-g•65.0°-g•75.06
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Family Tree of Installation
25° Pole Stanchion Pole Stanchion
Wall Arm
� 1��-:::�1
1
I
Dome Reflector
Adaptor Conduit
25° Pole Stanchion 3/4"or1"NPT
Pole Stanchion 3/4"or1"NPT
Wall Arm 3/4" or 1" NPT
Ex-Box +
Pendant Pole
� 12° Pendant Pole
T
FY
�
\
I I
Luminiare Body
Angle Reflector
Catalog No.
25DPS
PS
WA
Turnnion Bracket Expand Screw TB
Pendant Pole Use Ex-Box pp
12° Pendant Pole 3/4"or1"NPT 12 OPP
Ex-Box 3/4" NPT EB
13 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification Product Number --PT-60W DYZDA 60 4000K-5700K
PT-SOW DYZDA 80 4000K-5700K
PT-100W DYZDA 100 4000K-5700K
PT-120W DYZDA 120 4000K-5700K
PT-150W DYZDA 150 4000K-5700K
PT-180W DYZDA 180 4000K-5700K
PT-200W DYZDA 200 4000K-5700K
PT-220W DYZDA 220 4000K-5700K
Voltage Lumens
AC 100-277V or AC200-480V 8400
AC 100-277V or AC200-480V 11200
AC 100-277V or AC200-480V 14000
AC 100-277V or AC200-480V 16800
AC 100-277V or AC200-480V 21000
AC 100-277V or AC200-480V 25200
AC 100-277V or AC200-480V 28000
AC 100-277V or AC200-480V 30800
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
"D"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40 °
,60°
,90°
, 100°
, 110°
, 120°
Mechanical Information
AC200-480V models
Structure Diagram
Size (in)
15.7X11.3X10
15.7X11.3X10
0
I 15Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(220W)
l.O l.97
,., 7.86
Oistance[m] Pyramis Di11mele (ml
-co-C180(Halfdlvargenceangl11:108.4·J
161
E(O•) E(CO)
E(O•) !(CO)
!(0") E(CO)
E(o•J !{CO)
E(O") E(CO)
J�OS9
"''
""
, ..
illuminance[lx)
Plane illuminance curve
@J 6200
cd/m' -9-ss.O"-g•65.0°-9-1s.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
-, The specific steps of installation (Ceiling mounted)
. ..,4C-______________________ j
2
1. Take the fixture and accessory out from cartoon 2. Through the cable to flexible metal conduit and
box, tighten 2x angle holder screw as Fig.1. tighten it with the fixture.
3
)hll ______________ _) 3. Drill 2x hole as Fig.3, the distance can be 91-14Omm, fixing 01 O expansion screws and bracket on ceiling.
4 ///// //////!I fl I I l((l!'ff/l (-4(/// I I I I //I
i.111,r', l,IJIJrnl1: .17 J�i,A,:.,, ,.--jlG N
,1l,l/_p)1,,1/ij)l,ll,,u]1,,11,,1Ji_lJJ��.,
L, � � � L L ,�d
______________ ) 4. Connect the AC cable, Black cable joins to Live wire, white cable joins to Null wire, green cable joins to grounding.
The specific steps of installation (Wall mounted
2
2xFixingscrew
1. Take the fixture and accessory out from cartoon 2. Through the cable to flexible metal conduit and box, tighten 2x angle holder screw as Fig. 1. tighten it with the fixture.
3
11H11
3. Drill 2x hole as Fig.2, the distance can be 91-14Omm, fixing 010 expansion screws and bracket on the wall.
4
4. Connect the AC cable, Black cable joins to Live wire, white cable joins to Null wire, green cable joins to grounding.
1 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number
PT-40W EYZDA
PT-60W EYZDA
PT-SOW EYZDA
PT-1 OOW EYZDA
PT-120W EYZDA
PT-130W EYZDA
PT-140W EYZDA
PT-1 SOW EYZDA
--40 4000K-5700K
60 4000K-5700K
80 4000K-5700K
100 4000K-5700K
120 4000K-5700K
130 4000K-5700K
140 4000K-5700K
150 4000K-5700K
Voltage
AC90-295V
AC90-295V
AC90-305V
AC90-305V
AC90-305V
AC90-305V
AC90-305V
AC90-305V
Lumens
5600
8400
11200
14000
16800
18200
19600
21000
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
-70
70
70
70
70
70
70
70
"E"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40 °
,60°
,90°
, 100°
, 110°
, 120°
Mechanical Information
AC90-305V models
Structure Diagram
Size (in)
¢ 14x12.3
¢ 14x12.3
19 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(150W)
,., , ...
Distance[m] Pyramis Di11mela [m]
-Ol-C!aO(Halfdivergenceangle:110.6•)
201
!:(O•) 1SOSI
E(COJ su• 1665
E(O"J
E(CO)
E(O"J
E(CO)
E(O•J
!:(CO)
""
'"
E(0°) 87S
E(COJ 85
E(0°)
�(CO)
"'
"
illuminancelhr]
Plane illuminance curve
cd/m 2
-g-55.0"-g•65.0°-g•75.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Family Tree of Installation
25° Pole Stanchion Pole Stanchion
Wall Arm
I
� I
�
Spherical Glass Diffuser
Guard
Ex-Box
+
Pendant Pole
Turnnion Bracket 9
I
12° Pendant Pole
Flood Light
Angle Reflector
Dome Reflector
Adaptor Conduit Catalog No.
25° Pole Stanchion 3/4"or1"NPT 25DPS
Pole Stanchion 3/4"or1"NPT PS
Wall Arm 3/4" or 1" NPT WA
Turnnion Bracket Expand Screw TB
Pendant Pole Use Ex-Box pp
12° Pendant Pole 3/4"or1"NPT 12 OPP
Ex-Box 3/4" NPT EB
21 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flour mill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 1 00lm/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number Voltage --========= ===========
40 4000K-5700K AC 1 00-277V or AC200-480V
50 4000K-5700K AC 1 00-277V or AC200-480V
60 4000K-5700K AC 1 00-277V or AC200-480V
70 4000K-5700K AC100-277V or AC200-480V
80 4000K-5700K AC 1 00-277V or AC200-480V
90 4000K-5700K AC 1 00-277V or AC200-480V
PT-40W FYZDA
PT-SOW FYZDA
PT-60W FYZDA
PT-70W FYZDA
PT-BOW FYZDA
PT-90W FYZDA
PT-lOOW FYZDA 100 4000K-5700K AC100-277V or AC200-480V
Lumens
4000
5000
6000
7000
8000
9000
10000
Working Hours ========
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
"F"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40 °
,60°
,90°
, 100°
, 110°
, 120°
Mechanical Information
AC200-480V models
Structure Diagram
Size (in)
11.5x11.5x16.1
11.5x11.5x16.1
23 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to avoid
light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of workers,
improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(1 00W)
6.26
OiBtance[m] Pyramis Diamela (m)
-C0-ClB0(Halfdiv11rg11nc11angl11:90.2")
241
!(O•)
E(COJ
!(0") E(CO)
E(0°) E(CO)
E(0°J
E(CO}
E(0°) !(CO)
E(O"J E(CO)
11280 mo
'"
n
S% ..
"'
"
illuminance(l•I
Plane illuminance curve
cd/m2 -g-55.0"-g•65.0°-g•75.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Family Tree of Installation
25 ° Pole Stanchion Pole Stanchion
� I
�
Guard
Adaptor
25 ° Pole Stanchion
Pole Stanchion
Wall Arm
Ceiling Bracket
Pendant Pole
12° Pendant Pole
Ex-Box
Wall Arm
Ceiling Bracket
I
� LS
Ex-Box
+
Pendant Pole 12° Pendant Pole
Luminiare Body
Dome Reflector Angle Reflector
Conduit Catalog No.
3/4"or1"NPT 25 DPS
3/4"or1"NPT PS
3/4"or1"NPT WA
Expand Screw CB
Use Ex-Box pp
3/4"or1"NPT 12 OPP
3/4" NPT EB
2 5 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flour mill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 1 00lm/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number -- --10WGYZDA 70 10 4000K-5700K AC100-277V 1000 5 years
15WGYZDA 70 15 4000K-5700K AC100-277V 1500 5 years
20 4000K-5700K AC100-277V 2000 5 years
25 4000K-5700K AC100-277V 2500 5 years
30 4000K-5700K AC100-277V 3000 5 years
35 4000K-5700K AC100-277V 3500 5 years
40 4000K-5700K AC100-277V 4000 5 years
"G"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40' ,60' ,90', 100', 11 0', 120'
Mechanical Information
Size(in)
6.Bx6.Bx16.1
Structure Diagram
70
70
70
70
70
2 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to avoid
light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of workers,
improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(1 00W)
1.91
Dlstanc11[m] Pyramle Dlame:e [m]
-CO-CIBO(Halfdivergeneeangl<l:110.2")
2sl
E(0°) 96SO
E(CO) 45.l" 990
E(O")
E(CO)
E{O")
E(CO)
E{O"l 961 E(COJ 90
E(O"J
E{COJ
E(O")
E(COJ
,..
"
lllumlnance[lx]
Plane illuminance curve
cd/m' -g-55.0"-g-65.0"-g-75.06
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Family Tree of Installation
25 ° Pole Stanchion Pole Stanchion
�
Guard
Adaptor
25 ° Pole Stanchion
Pole Stanchion
Wall Arm
Ceiling Bracket
Pendant Pole
12° Pendant Pole
Ex-Box
Wall Arm
�E;;;;;;;;;;�i1J�I ' �
Ceiling Bracket
LS
Luminiare Body
Dome Reflector
Ex-Box +
Pendant Pole
912° Pendant Pole
�
Angle Reflector
Conduit Catalog No.
3/4" or 1" NPT 25 DPS
3/4" or 1" NPT PS
3/4"or1"NPT WA
Expand Screw CB
Use Ex-Box pp
3/4" or 1" NPT 12 OPP
3/4" NPT EB
2 9 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number --- Voltage Lumens
10 4000K-5700K AC 1 00-277V or AC200-480V 1400
15 4000K-5700K AC 1 00-277V or AC200-480V 2100
20 4000K-5700K AC100-277V or AC200-480V 2800
25 4000K-5700K AC100-277V or AC200-480V 3500
30 4000K-5700K AC 1 00-277V or AC200-480V 4200
30 4000K-5700K AC100-277V or AC200-480V 4200
35 4000K-5700K AC100-277V or AC200-480V 4900
40 4000K-5700K AC 1 00-277V or AC200-480V 5600
4 5 4000K-5700K AC100-277V or AC200-480V 6300
50 4000K-5700K AC 1 00-277V or AC200-480V 7000
55 4000K-5700K AC100-277V or AC200-480V 7700
PT-lOW H2YZDA
PT-lSW H2YZDA
PT-20W H2YZDA
PT-2SW H2YZDA
PT-30W H2YZDA
PT-30W H4YZDA
PT-3SW H4YZDA
PT-40W H4YZDA
PT-4SW H4YZDA
PT-SOW H4YZDA
PT-SSW H4YZDA
PT-GOW H4YZDA 60 4000K-5700K AC 1 00-277V or AC200-480V 8400
"H"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle: 120°
Mechanical Information
AC200-480V models
Structure Diagram
ti
Size (in)
24x4.7x9.5
24x4.7x9.5
Size(in)
47x4.7x9.5
47x4.7x9.5
11 JI If: 11 ,;
1i:0: : : : : : :0:i (0: : : : : : :)JI
�I n
1l ti II II 11 II ,;
1[<1 : : : : : i,J1
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
70
70
70
70
J } Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
�//////////////////) Ceiling
mounting
-
'- /
\,_
Wall
mounting
J J Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
===-== Product Number Color
30 4000K-5700K
40 4000K-5700K
50 4000K-5700K
60 4000K-5700K
60 4000K-5700K
70 4000K-5700K
80 4000K-5700K
90 4000K-5700K
100 4000K-5700K
110 4000K-5700K
PT-30W I2YZDA
PT-40W I2YZDA
PT-SOW I2YZDA
PT-60W I2YZDA
PT-60W I4YZDA
PT-70W I4YZDA
PT-BOW I4YZDA
PT-90W I4YZDA
PT-100W I4YZDA
PT-110W I4YZDA
PT-120W I4YZDA 1 20 4000K-5700K
Voltage
AC 100-277V or AC200-480V 4200
AC 100-277V or AC200-480V 5600
AC100-277V or AC200-480V 7000
AC 100-277V or AC200-480V 8400
AC 100-277V or AC200-480V 8400
AC 100-277V or AC200-480V 9800
AC 100-277V or AC200-480V 11200
AC 100-277V or AC200-480V 12600
AC 100-277V or AC200-480V 14000
AC100-277V 15400
AC100-277V 16800
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
70
70
70
"!"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle: 120°
Mechanical Information
AC200-480V models
Structure Diagram
0
Size (in)
24x5.5x8.1
24x5.5x8.1
di
Size (in)
47x5.5x8.1
47x5.5x8.1
n
It
I�
0
J 5 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
cd/klm -90-270
Light intensity curve (120W)
Oistance[m] Pyramis Diam11te [ml -CO-CISO(Halfdiv•rg•nc•a"lll•:111.'I")
E[0°) l�OO !(COJ S!.7° UOl
E(O") 1812
E(COJ 55.7° 220
!(0°) 100'5 E(CO) 55.7" 11.Z
E[O"J 108
!(CO) 55.7° 78
E(0°) I�
E(CO) 55.7° .J.O
illuminanc11[1x]
Plane illuminance curve
cd/m 2
-9•5S.O"-g•65.0°-g•75.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the light fixture.
Mounting Option Note: Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
I I �
�I ; I�!I ii
Suspend Mount Pole Pendant Mount
fl 11
Trunnion Mount Ceiling Mounting
Wall Mounting
J 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 140Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598/U L 1598A/U L844
• CSA C22.2 No.137/No.250.0
Class I, Division 1, Groups C,D
Class I, Division 2, Groups A,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups E,F,G
Class Ill
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number ===-== Color
PT-20W D2YZDA 20 4000K-5700K
PT-30W D2YZDA 30 4000K-5700K
PT-40W D2YZDA 40 4000K-5700K
PT-50W D2YZDA 50 4000K-5700K
PT-60W D2YZDA 60 4000K-5700K
PT-70W D2YZDA 70 4000K-5700K
PT-BOW D2YZDA 80 4000K-5700K
Voltage - -========== ========
AC 100-277V or AC200-480V 2800
AC 100-277V or AC200-480V 4200
AC 100-277V or AC200-480V 5600
AC 100-277V or AC200-480V 7000
AC 100-277V or AC200-480V 8400
AC100-277V 9800
AC100-277V 11200
5 years
5 years
5 years
5 years
5 years
5 years
5 years
70
70
70
70
70
70
70
"D2"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:4O' ,60' ,90', 100', 11 0', 120'
Mechanical Information
AC200-480V models
Structure Diagram
Size (in)
11.6x11.6x9.55
11.6x11.6x9.55
J 9 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
Light intensity curve(SOW)
1.0
E(O') "'" 1.91 E{CO) 1220
E(O') MM
'4.13 E(COJ '"
E(O') '·'° !(CO)
!(0') '"
,., 8.26 E(COl '"
E(O') 11.03 !(CO) "
E(O') ow
19.20 E(CO)
Oistance[m] Pyremis Oiemete (ml illuminance[lx)
-co-c1SO(Halldlverganc1angle:108.4")
401
Plane illuminance curve
C270 @] ""
cd/m' -g•5S.O"-g•65.0°-g•75.0°
C90
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
-, The specific steps of installation (Ceiling mounted)
. ..,4C-______________________ j
2
1. Take the fixture and accessory out from cartoon 2. Through the cable to flexible metal conduit and
box, tighten 2x angle holder screw as Fig.1. tighten it with the fixture.
3
)hll ______________ _) 3. Drill 2x hole as Fig.3, the distance can be 91-14Omm, fixing 01 O expansion screws and bracket on ceiling.
4 ///// //////!I fl I I l((l!'ff/l (-4(/// I I I I //I
i.111,r', l,IJIJrnl1: .17 J�i,A,:.,, ,.--jlG N
,1l,l/_p)1,,1/ij)l,ll,,u]1,,11,,1Ji_lJJ��.,
L, � � � L L ,�d
______________ ) 4. Connect the AC cable, Black cable joins to Live wire, white cable joins to Null wire, green cable joins to grounding.
The specific steps of installation (Wall mounted
2
2xFixingscrew
1. Take the fixture and accessory out from cartoon 2. Through the cable to flexible metal conduit and box, tighten 2x angle holder screw as Fig. 1. tighten it with the fixture.
3
11H11
3. Drill 2x hole as Fig.2, the distance can be 91-14Omm, fixing 010 expansion screws and bracket on the wall.
4
4. Connect the AC cable, Black cable joins to Live wire, white cable joins to Null wire, green cable joins to grounding.
41 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Petroleum Industry
• Petrochemical Industry
• Metallurgical Industry
• Power Generation Industry
• Power Transmission Industry
• Machine Manufacturing
• Drilling platform
• Single point mooring
• Oil tank
• Workover platform
• Production platform
• Field tank
• Manifold center!
• Pumping station
• Gasoline station
• Transformer station, Coating plant , Warehouse. etc.
Features
• LED source. Long lifespan. High lumen output.
• Good heat dissipation, long life span
• Shock-and vibration-resistant-tempered glass, reduces
the risk of premature failure
• Explosion proof design can use in the hazardous application
• High strength aluminum alloy housing. can endure 20 J impact
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598A/UL844/UL924
• CSA C22.2 No.137
CSA C22.2 No.250.0
Class I Division 2,Groups A, B, C, D
Class I Division 2,Groups F, G
Class Ill
UL Compliant
ABS Compliant
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L 70 rating for more than 150000 hours
.... 1.
lighting
f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number -- Color
PT-3W KNZDA 3W RED
Mechanical Information
Structure Diagram
Technical Data
Permissible ambient temperature:
Power:
Rated voltage AC:
Frequency:
Battery Warranty:
Enclosure material:
Size(in)
24x5.4x3.5
1 o·c-+ss·c
3W
AC100-277V
50/60Hz
5 Years
Copper free aluminium alloy
Voltage Working Hours illumination Time
AC100-277V 5 years 3 hours
43 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flour mill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 1 00lm/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA4X, IP66
• UL 1598 /U L 1598A/U L844
• CSAC22.2 No.137
CSA C22.2 No.250.0
Class I Divison 2 Groups A, B, C, D
UL Compliant
ABS Compliant
• M arine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
c@us ligtiii�g LISTED f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number -- Color
PT-FL-BOW 80 2700K-6400K
PT-FL-120W 120 2700K-6400K
PT-FL-lSOW 150 2700K-6400K
PT-FL-200W 200 2700K-6400K
PT-FL-240W 240 2700K-6400K
Mechanical Information
BOW Size (in)
15.8x6.4x6.7
Structure Diagram
200W, 240W
120W, 150W
80W
Voltage Lumens
AC100-277V 8000
AC100-277V 12000
AC100-277V 15000
AC100-277V 20000
AC100-277V 24000
120/150W Size (in) 200/240W Size (in)
15.8x6.6x8. 7 16.7x6.6x13.9
Working Hours
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
4 5 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to avoid
light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of workers,
improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
160170180170150 150 150
110 130
120 110 100 100 90 90
80
cd/klm
160170180170150 150 150
140 40 130 130
120v--../'-A U1rt"H 120 110 110 100 100
90 90
cd/klm
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
I I
L/"
J",
Lr.•;; (unit:mm)
�11-··Lt "'-1�, I 11 H
Power(W) 240 200 150 120 80
Pole mount
L(mm) 520 520 420 420 420
Power(W) 240 200 150 120 80
l(mm) 520 520 420 420 420
Wall mount
(unit:mm)
Pendant mount 200W, 240W
Pipe clamp
,/���, l]'''-�.� ,;-· ==::::: �:, 5 ./
= ;
,
(unit:mm)
w_L11
Power(W) 240 200 150 120 80
L(mm) 520 520 420 420 420
Stanchion mount
(unit:mm)
-+'_),'>>-. ,
fPower BOW 120W 150W
w{mm) 110 190 190
80W, 120W, 150W
(unit:mm)
80 120 150
210 260 260
203 253 253
14 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Refinery factory
• Oil and gasoline loading dock
• Gas station
• Painting manufacture workshop
• Pumping station
• Metal Smelting Plant
• Mining
• Ocean platform
• Aerospace
• Chemical plant
• Vessel
• Military
• Flourmill
• Distillerie
• Power station
• Other high humility, high temperature, dusty location ...
Features
• High efficacy: up to 125Im/W
• CRl>70
• Surface mounting and pendant installation
• Wide and narrow optics for uniform illumination
• Copper free aluminum
• High vibration resistance
Ratings and Certifications
• NEMA4X, IP66
• UL 1598 /U L 1598A/U L844
• CSAC22.2 No.137
CSA C22.2 No.250.0
Class I Divison 2, Groups A, B, C, D
Class II Divison 2, Groups F, G
Class Ill
• M arine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L70 rating for more than 150000 hours
c@us ligtiii�g LISTED f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Typical Model Specification
Product Number - Color
PT-36W2FT
PT-48W2FT
PT-56W2FT
PT-36W4FT
PT-48W4FT
PT-56W4FT
PT-72W4FT
PT-100W4FT
36
48
56
36
48
56
72
100
2700K-6400K
2700K-6400K
2700K-6400K
2700K-6400K
2700K-6400K
2700K-6400K
2700K-6400K
2700K-6400K
Mechanical Information
2FT Size (in)
24x5.4x3.5
Structure Diagram
Voltage Lumens
AC100-277V 4554
AC100-277V 6072
AC100-277V 7086
AC100-277V 4554
AC100-277V 6072
AC100-277V 7086
AC100-277V 9108
AC100-277V 12650
4FT Size (in)
47x5.4x3.5
[VIJlirtl/1,rrUJA I_ .. I -
2FT 36W48W 56W
4FT 36W 48W 56W 72W 100W
; /
Working Hours
5 years
5 years
5 years
5 years
5 years
5 years
5 years
5 years
--70
70
70
70
70
70
70
70
4 9 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
The unique light distribution design, light type and angle precision control of the LED light source, to
avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of
workers, improve working efficiency.
Professional Light Distribution
Light Distribution Pattern
cd/klm -90-270
Light intensity curve(120W)
Oistance[m] PyramisDiam11te [ml
-CO·Cl80(Halfdiv•rg'"1ct1angl•:111.4•)
E(O") 12550 [(CO) S!.7° 10!9
E(O") E(CO) 55.7° 163
E(O"l !169 E(CO) SS.7" 92
E(0°) H2 E(CO) 5!.7° H
E(0°) 102 E(ca) 55.7°
illuminanc11llx]
Plane illuminance curve
cd/m 2
-g-55.� -g•6S.0° -g-75.0°
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Mounting Method
Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the
light fixture.
Mounting Option Note:
Pendant mounting option requires conduit be supplied by the installer.
Rectangle luminaire mounting
L
L
Unit: mm
L(Max) L(Min) 0.6M 550 500 1.2M 1150 500
Pipe clamp
Unit: mm
180 °
\<,)\0
j
L(Max) L(Min) 0.6M 625 575 1.2M 1225 575
Stanchion mount
Unit: mm
L(Max) L(Min) 0.6M 550 500 1.2M 1150 500
Ceiling Mount
1/'1/r:;
t
L
L
0.6M 1.2M
Wall mount
T
Unit: mm
L(Max) L(Min) 625 575 1225 575,,,
Unit: mm
j/rny·· /1 �
I
L(Max) L(Min) T(Max) T(Min) 0.6M 1.2M
620 570 1220 570
Clamp mount
" / /2/2%1////1/4? / 1/
L
40 5
Unit: mm , /i/4u
fl
0 11 E-Illltt(!Hlliff 'r 1i-
'-- - - - _..,!
L(Max) L(Min) 0.6M 550 500 1.2M 1150 500
Pendant Mount
51 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Applications
This luminaire can be used as spot light, down light
and tunnel light which can provide general illumination
in hazardous locations, such as:
• Petroleum Industry
• Petrochemical Industry
• Metallurgical Industry
• Power Generation Industry
• Power Transmission Industry
• Machine Manufacturing
• Drilling platform
• Single point mooring
• Oil tank
• Workover platform
• Production platform
• Field tank
• Manifold center!
• Pumping station
• Gasoline station
• Transformer station, Coating plant ,Warehouse .etc.
Features
• LED source. Long lifespan. High lumen output.
• Good heat dissipation, long life span
• Shock- and vibration-resistant-tempered glass, reduces
the risk of premature failure
• Explosion proof design can use in the hazardous application
• High strength aluminum alloy housing. can endure 20 J impact
Ratings and Certifications
• NEMA 4X, IP66
• UL 1598A/UL844/UL924
• CSA C22.2 No.137
CSA C22.2 No.250.0
Class I Division 2,Groups A, B, C, D
Class I Division 2,Groups F, G
Class Ill
UL Compliant
ABS Compliant
• Marine and Wet Locations
• IECEX
• ATEX
• 5 years or other warranty period specified in agreement
• L 70 rating for more than 150000 hours
c@us ligtiii�g LISTED f!�!!" FC RoHS
Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com
Axis LED Group171 N Aberdeen St, Chicago, IL 60607 Telephone: +1 866.258.0592, (312) 470.8058FAX: +1 877-793-4877E-mail: [email protected] Website: www.patriotled.com: www.alg-usa.com