4
Hazardous Location/Explosion Proof Conduit Products Class I, II and III (Groups A-G) Hazardous Locations UL 1203/CSA 22.2 approved NEC Compliant Made in the USA A division of

Hazardous Location/Explosion Proof Conduit Products...• Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hazardous Location/Explosion Proof Conduit Products...• Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2

Hazardous Location/Explosion Proof Conduit Products

Class I, II and III (Groups A-G)

Hazardous Locations

UL 1203/CSA 22.2 approved

NEC Compliant

Made in the USA

A division of

Page 2: Hazardous Location/Explosion Proof Conduit Products...• Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2

PVC Coated GUA Junction Boxes

PVC Coated Sealing Fittings

PVC Coated Unions

FEATURES• Exterior PVC coating thickness is a minimum 0.040"• Interior Urethane coating thickness is a minimum 0.002"• Sizes available are ½" to 2"• Sealing sleeves extends 1 pipe diameter or 2", whichever is greater, beyond all female openings

STANDARDS:• National Electrical Code: Class I, Div 1&2, Groups C,D Class III• UL Standard 886• ANSI Standard C-33.27• CSA Standard: C22.2 No. 30• NEMA/EEMAC 3, 4

FEATURES• Exterior PVC coating thickness is a minimum 0.040"• Interior Urethane coating thickness is a minimum 0.002"• Sizes available are ½" to 4"• Sealing sleeves on all conduit hubs• Sealing sleeve is provided on plug hub (patching compound recommended on top of plug)• Mating sealing forms are provided on all caps

STANDARDSEYS-1-3, 11-31,16-36 EYS-29, 4-014,46-0146 EYD-11-101, 116-1016• Class I, Div 1&2, EZS-1-8, 16-86 • Class I, Div 1&2, Groups A, B, C, D • Class I, Div 1&2, Groups B, C, D• Class lll Groups C, D • Class lllEYS-41-101, 416-1016 • Class lll EYD-1-10, 16-106 • Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2 No.30 Groups C, D • Class lll

Stainless Steel Explosion Proof UNY

Stainless Steel Explosion Proof GUAT

Stainless Steel Explosion Proof EYS

FEATURES• Manufactured in type 316 stainless steel to meet any stringent sanitary condition• Polished with standard "brite" finish to increase corrosion resistance and aesthetic appearance• Explosion proof, dust-ignition proof• Designed for use with stainless steel threaded conduit• Designed for use with vertical and horizontal installations (EYS)• Large opening for easy packing and setup of sealing compound and fiber dam (EYS)• Machined tapered female threads for smooth bore inside diameter (GUAT / EYS)• Tightening “Ears” cast into cover to allow for easy tightening and removal (GUAT)• Grounding screw provided (GUAT)• Neoprene O-ring included (GUAT)• NPT male threads and machined tapered female threads for smooth bore inside diameter (UNY)• No package qty. required

CERTIFICATIONS & COMPLIANCES• UL 1203 Approved• CSA C22.2 Approved• Suitable for use in Class I Division 1 Groups A,B,C and D; Class II Division 1• Groups E, F and G; and Class III Hazardous Locations• Manufactured in the USA

GUAT

UNYEYS

GUAX

GUAD GUAB

EYD

EYSEYS M-F

Page 3: Hazardous Location/Explosion Proof Conduit Products...• Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2

PVC Coated GUA Junction Boxes

PVC Coated Sealing Fittings

PVC Coated Unions

FEATURES• Exterior PVC coating thickness is a minimum 0.040"• Interior Urethane coating thickness is a minimum 0.002"• Sizes available are ½" to 2"• Sealing sleeves extends 1 pipe diameter or 2", whichever is greater, beyond all female openings

STANDARDS:• National Electrical Code: Class I, Div 1&2, Groups C,D Class III• UL Standard 886• ANSI Standard C-33.27• CSA Standard: C22.2 No. 30• NEMA/EEMAC 3, 4

FEATURES• Exterior PVC coating thickness is a minimum 0.040"• Interior Urethane coating thickness is a minimum 0.002"• Sizes available are ½" to 4"• Sealing sleeves on all conduit hubs• Sealing sleeve is provided on plug hub (patching compound recommended on top of plug)• Mating sealing forms are provided on all caps

STANDARDSEYS-1-3, 11-31,16-36 EYS-29, 4-014,46-0146 EYD-11-101, 116-1016• Class I, Div 1&2, EZS-1-8, 16-86 • Class I, Div 1&2, Groups A, B, C, D • Class I, Div 1&2, Groups B, C, D• Class lll Groups C, D • Class lllEYS-41-101, 416-1016 • Class lll EYD-1-10, 16-106 • Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2 No.30 Groups C, D • Class lll

Stainless Steel Explosion Proof UNY

Stainless Steel Explosion Proof GUAT

Stainless Steel Explosion Proof EYS

FEATURES• Manufactured in type 316 stainless steel to meet any stringent sanitary condition• Polished with standard "brite" finish to increase corrosion resistance and aesthetic appearance• Explosion proof, dust-ignition proof• Designed for use with stainless steel threaded conduit• Designed for use with vertical and horizontal installations (EYS)• Large opening for easy packing and setup of sealing compound and fiber dam (EYS)• Machined tapered female threads for smooth bore inside diameter (GUAT / EYS)• Tightening “Ears” cast into cover to allow for easy tightening and removal (GUAT)• Grounding screw provided (GUAT)• Neoprene O-ring included (GUAT)• NPT male threads and machined tapered female threads for smooth bore inside diameter (UNY)• No package qty. required

CERTIFICATIONS & COMPLIANCES• UL 1203 Approved• CSA C22.2 Approved• Suitable for use in Class I Division 1 Groups A,B,C and D; Class II Division 1• Groups E, F and G; and Class III Hazardous Locations• Manufactured in the USA

GUAT

UNYEYS

GUAX

GUAD GUAB

EYD

EYSEYS M-F

Page 4: Hazardous Location/Explosion Proof Conduit Products...• Class I, Div 1&2, EZD-10-60, 111-611 Groups B, C, D UL Standard 886 • Class I, Div 1&2, • Class lll CSA Standard: C22.2

2016 EXP-Rev A

CALBOND MANUFACTURING FACILITY923 Calpipe Rd.Santa Paula, CA 93060(562) 803-4388(310) 885-1894 faxcalbond.com

CALBRITESOUTHEAST301 Mears Blvd., Ste. AOldsmar, FL 34677(219) 844-6800(800) 536-2248(219) 844-6884 fax

CALPIPECORPORATEHEADQUARTERS19440 S. Dominguez Hills Dr. Rancho Dominguez, CA 90220(800) Calpipe(562) 803-4388calpipe.com

CALBRITEMIDWEST (Sales Office)6451 Northwind ParkwayHobart, IN 46342(219) 844-6800(800) 536-2248(219) 844-6884 faxcalbrite.com

Protect Your Assets with Hazardous Location

Conduit Products. Calpipe Industries, Inc. provides the complete and total

protection solution for yourconduit system, before

corrosive elements threaten your business.

Serving these Markets

Food and Beverage

Chemical Plants

Water and Wastewater Treatment

Pharmaceutical and Cosmetics

Refining and Extraction Sites

Petrochemical

Pulp and Paper Mills

Marine and Coastal Facilities

Hazardous Location/Explosion Proof Conduit Products

Class I, II and III (Groups A-G)

Hazardous Locations

UL 1203/CSA 22.2 approved

NEC Compliant

Made in the USA

A division of