16
FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, injury, or death. - Do not store or use gasoline or other flam- mable vapors or liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS OWNER’S MANUAL FOR YOUR SAFETY This product must be installed and serviced by authorized personnel, qualified in pool/spa heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases that can cause serious injury, property damage, or death. 1301640701 Rev C XXXX HAYWARD ®

Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Embed Size (px)

Citation preview

Page 1: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

FOR YOUR SAFETY

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, injury, or death.

- Do not store or use gasoline or other flam-mable vapors or liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS: • Donottrytolightanyappliance.• Donottouchanyelectricalswitch;donotuse

any phone in your building. • Immediatelycallyourgassupplierfroma

neighbor’sphone.Followthegassupplier’sinstructions.

• Ifyoucannotreachyourgassupplier,callthefire department.

-Installationandservicemustbeperformedbyaqualifiedinstaller,serviceagency,orthegassupplier.

POOL AND SPA/HOT TUB HEATERSH150FD, H200FD, H250FD, H300FD,

H350FD & H400FD MODELS

OWNER’S MANUAL

FOR YOUR SAFETYThisproductmustbeinstalledandservicedbyauthorizedpersonnel,qualifiedinpool/spaheaterinstallation.Improperinstallationand/oroperationcancreatecarbonmonoxidegasandfluegasesthatcancauseseriousinjury,propertydamage,ordeath.

1301640701 Rev C XXXX

HAYWARD ®

Page 2: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Warnings ....................................................................................................3-6

Section I General information ........................................................................7

Section II. Consumer Operation & Maintenance ...........................................8

Using chlorinators and chemical feeders:......................................................9

Lighting & Operating instructions label ........................................................10

Operation: Set point adjustment .................................................................11

Fahrenheit versus Celsius ...........................................................................11

Sequence of operation ...............................................................................11

Failure to Light .............................................................................................12

Loss of flame – recycle ................................................................................12

Adaptive learning routine .............................................................................13

Keypad inputs ..............................................................................................13

Automatic reset time ....................................................................................13

Periodic inspection: .....................................................................................13

Winterization: ...............................................................................................14

Damage by Freezing ...................................................................................14

Spring start-up: ............................................................................................15

Error codes .............................................................................................15-16

Contents

Page 3: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Basicsafetyprecautionsshouldalwaysbefollowed,includingthefollowing:Failuretofollowinstructionscancausesevereinjuryand/ordeath.

Thisisthesafety-alertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookforoneofthefollowingsignalwordsandbealerttothepotentialforpersonalinjury.

WARNINGwarnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormajorpropertydam-ageandifignoredpresentsapotentialhazard.

CAUTIONwarnsabouthazardsthatwillorcancauseminorormoderatepersonalinjuryand/orprop-ertydamageandifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthatareunpredictableandunsafe.

ATTENTIONindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.

ReAD AnD FoLLoW ALL InstRUCtIons In tHIs oWneR’sMAnUAL AnD on eQUIPMent.

IMPoRtAnt sAFetY InstRUCtIonsBefore installing or servicing this electrical equipment, turn power supply oFF.

KeeP sAFetY LABeLs In GooD ConDItIon AnD RePLACe IF MIssInG oR DAMAGeD.

WARNING–Toreduceriskofinjury,donotpermitchildrentouseorclimbontheheater,pumpsorfilters.Closelysupervisechildrenatalltimes.Componentssuchasthefiltrationsystem,pumps,andheatersmustbepositionedtopreventchildrenfromusingthemasameansofaccesstothepool.CAUTION –Thisheaterisintendedforuseonpermanentlyinstalledswimmingpoolsandmayalsobeusedwithspas.DoNOTusewithstorablepools.Apermanentlyinstalledpoolisconstructedinoronthegroundorinabuildingsuchthatitcannotbereadilydisassembledforstorage.Astorablepoolisconstructedsothatitiscapableofbeingreadilydisassembledforstorageandreassembledtoitsoriginalintegrity.

Thoughthisproductisdesignedforoutdooruse,itisstronglyrecommendedtoprotecttheelectricalcomponentsfromtheweather.Selectawelldrainedarea,onethatwillnotfloodwhenitrains.Itrequiresfreecirculationofairforcooling.Donotinstallinadampornon-ventilatedlocation.

WARNING –Itisrequiredthatlicensedelectriciansdoallelectricalwiring.RiskofElectricShock.Hazardousvoltagecanshock,burn,causedeathorseriouspropertydamage.Toreducetheriskofelectricshock,doNOTuseanextensioncordtoconnectunittoelectricsupply.Provideaproperlylocatedoutlet.AllelectricalwiringMUSTbeinconformancewithapplicablelocalandnationalcodesandregulations.Beforework-ingonthisunit,turnoffpowersupplytotheheater.

WARNING –Toreducetheriskofelectricshockreplacedamagedwiringimmediately.Locateconduittopreventabusefromlawnmowers,hedgetrimmersandotherequipment.

WARNING –Failuretobondtopoolstructurewillincreaseriskforelectrocutionandcouldresultininjuryordeath.Toreducetheriskofelectricshock,theelectricianmustcomplywithinstallationin-structionsandmustbondtheheateraccordingly.Inaddition,thelicensedelectricianmustalsoconformtolocalelectricalcodesforbondingrequirements.

sAFetY InFoRMAtIon

Page 4: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

notes to tHe eLeCtRICIAn:Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-

forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedontheheaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(exceptgaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.

IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,bondingandothergeneralwiringprocedures.

WARNING – Suction Entrapment Hazard.Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-lowingentrapmenthazards:

Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.

Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutletcoverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultinamechanicalbindorswellingofthelimb.

Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscanresultinanentrapment.

Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotectedsuctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecuredcanresultinevisceration(disembowelment).

Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,finger,toeorknuck-letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-ment.

WARNING-Toreducetheriskofentrapmenthazards:• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.floororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-suredfromnearpointtonearpoint.

• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dualblockage”byauser.

• Dualsuctionfittingsshallnotbelocatedonseatingareasoronthebackrestforsuchseatingareas.

• Themaximumsystemflowrateshallnotexceedtheflowratingofanylisted(percurrentrevisionofASME/ANSIA112.19.8)suctionoutletcoverinstalled.

• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,ornotsecurelyattached.

• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-mediately.

• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.

Page 5: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

5

WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spafromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.

WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paperandothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.

WARNING–Suctionoutletcomponentshaveafinitelife,thecover/grateshouldbeinspectedfre-quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornotsecurelyattached.

WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.AlldrainsandsuctionoutletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.

WARNING – Hazardous Pressure.Poolandspawatercirculationsystemsoperateunderhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafetyandoperationinstructionscouldresultinviolentseparationofthepumphousingandcoverduetopressureinthesystem,whichcouldcausepropertydamage,severepersonalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,allsystemandpumpcontrolsmustbeinoffpositionandfiltermanualairreliefvalvemustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbesetinapositiontoallowsystemwatertoreturnbacktothepool.Donotchangefiltercontrolvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,fullyopenfiltermanualairreliefvalve.Donotclosefiltermanualairreliefvalveuntilasteadystreamofwater(notairorairandwater)isdischarged.

WARNING – Separation Hazard.Failuretofollowsafetyandoperationinstruc-tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbeproperlysecuredtopumphousingwithstrainercoverlockring.Beforeservicingpoolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Donotoperatepoolandspacirculationsystemifasystemcomponentisnotassembledproperly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunlessfilterairreliefvalvebodyisinlockedpositioninfilterupperbody.

WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.

WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperlyisolatedfromanyflammablestructuresorforeigndebristheycancausefires,whichmaycauseseverepersonalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriortomaintenancetominimizetheriskofburns.

WARNING–Failuretoinstallaccordingtodefinedinstructionsmayresultinseverepersonalinjuryordeath.

Page 6: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

WARNING–Thefollowing“SafetyRulesforHotTubs”recommendedbytheU.S.ConsumerProductSafetyCommissionshouldbeobservedwhenusingthespa.

1. Spaorhottubwatertemperaturesshouldneverexceed104°F[40°C].Atemperatureof100°F[38°C]isconsideredsafeforahealthyadult.Specialcautionissuggestedforyoungchildren.Pro-longedimmersioninhotwatercaninducehyperthermia.

2. Drinkingofalcoholicbeveragesbeforeorduringspaorhottubusecancausedrowsiness,whichcouldleadtounconsciousnessandsubsequentlyresultindrowning.

3. Pregnantwomenbeware!Soakinginwaterabove100°F[38°C]cancausefetaldamageduringthefirstthreemonthsofpregnancy(resultinginthebirthofabrain-damagedordeformedchild).Preg-nantwomenshouldadheretothe100°F[38°C]maximumrule.

4. Beforeenteringthespaorhottub,usersshouldcheckthewatertemperaturewithanaccuratether-mometer;spaorhottubthermostatsmayerrinregulatingwatertemperaturesbyasmuchas4°F(2.2°C).

5. Personstakingmedications,whichinducedrowsiness,suchastranquilizers,antihistaminesoranti-coagulants,shouldnotusespasorhottubs.

6. Ifthepool/spaisusedfortherapy,itshouldbedonewiththeadviceofaphysician.Alwaysstirpool/spawaterbeforeenteringthepool/spatomixinanyhotsurfacelayerofwaterthatmightexceedhealthfultemperaturelimitsandcauseinjury.Donottamperwithcontrols,becausescaldingcanresultifsafetycontrolsarenotinproperworkingorder.

7. Personswithamedicalhistoryofheartdisease,circulatoryproblems,diabetesorbloodpressureproblemsshouldobtainaphysiciansadvicebeforeusingspasorhottubs.

8. Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegreesabovenormalbodytemperatureof98.6°F[37°C].ThesymptomsofHyperthermiainclude:drowsi-ness,lethargy,dizziness,fainting,andanincreaseintheinternaltemperatureofthebody.

The effects of Hyperthermia include:1. Unawarenessofimpendingdanger.2. Failuretoperceiveheat.3. Failuretorecognizetheneedtoleavethespa.4. Physicalinabilitytoexitthespa.5. Fetaldamageinpregnantwomen.6. Unconsciousnessresultingindangerofdrowning.

DEFINITIONS:SuctionOutlet– ThetermSuctionOutletisafitting,fittingassembly,cover/grateandrelatedcompo-

nentsthatprovideameansforwatertoexitthepoolandintothepumpcirculatingsystem.

InchesofMercury(inHg)- Aunitformeasuringpressurebelowatmospheric(“suction”or“vacuum”)(1.0inch

Hg=.491PSI)MainDrain– SeeSuctionOutletPSI– Anabbreviationforpoundspersquareinch.

Page 7: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

IntRoDUCtIon:Thismanualcontainsinstructionsforinstallation,operation,maintenance,troubleshooting,andpartslists

forthesafeuseoftheswimmingpool/spa/hottubheaters.Haywardstronglyrecommendsthattheownerreadthemanualbeforeusingtheswimmingpool/spa/hottubheater.Ifafterreviewingthemanualanyques-tionsremainunanswered,contactthefactoryorlocalrepresentative.

LIMIteD WARRAntY sUMMARY:Wewarrantthepool/spa/hottubheatertobefreefromdefectsinmaterialsandworkmanship,andwe

willwithinoneyearfromdateofinstallationforallusers,fortheoriginalpurchaser,repairor,atouroption,replacewithoutchargeanydefectivepart.Wefurtherwarrantthatiftheheatexchangerorexchangerheaders(water-containingsection)leakwithinoneyearfromdateofsuchinstallationforallusers,duetodefectsinmaterialsandworkmanship,wewillprovideareplacementpart.Costoffreight,installation,fuel,andservicelabor(afteroneyear)isatuser’sexpense.Forfulldetailsofwarrantyagreement,seewarrantycertificateincludedinthismanual.

ATTENTION:Ifthepool/spa/hottubheaterisdamagedordestroyedbyimpropermaintenance,exces-sivewaterhardness,incorrectwaterchemistry,orfreezingitisnotcoveredunderthemanufacturer’swarranty.

seCtIon I. GeneRAL InFoRMAtIon

Page 8: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

8 seCtIon II. ConsUMeR oPeRAtIon & MAIntenAnCe

FoR YoUR sAFetY – ReAD BeFoRe oPeRAtInG tHe HeAteR

GENERAL:Watermustbeflowingthroughtheheaterduringoperation.Checkthatthepumpisoperatingandthesys-

temisfilledwithwaterandpurgedofallairpriortostartingtheheater.Inanewpoolitisrecommendedthatthefilterbeoperatedlongenoughtocompletelycleanandclearthepoolwaterandfiltersystem.

Balancethepool/spawaterchemistryandcleanthefilter.Thenfollowtheinstructionsbelow.

POOL/SPA WATER CHEMISTRY:SeeFigure1.Themineralcontentofswimmingpoolwaterincreasesdailyduetoadditionofpoolsanitiz-

ingchemicalsandnaturalevaporation.Excessmineralswilldepositonpoolwalls,inthefiltrationsystem,andintheheatexchangertubesifthemineralcontentistoohigh.

Changingspawaterregularlyandmaintainingcorrectchemicalbalanceinpool/spawillkeepthepool/spasafeandsanitary,andwillprotecttheheateranditswarrantycoverage.PurchaseaPHwatertestkitandcheckthefollowingchemicallevelsfrequently.

CHLORINE OR BROMINE:Recommendedlevelis1to4ppm.Testbeforeuse.pH:Recommendedideallevel7.4to7.6.HIGHreadingsreducesanitizerefficiency.LOWreadingsarecorrosive.

TOTAL ALKALINITY:80–120ppm.Testweeklyduringregularuse.LOWreadingsarecorrosiveandcauserapidpHchangeswhenchemicalsareadded.

CALCIUM HARDNESS:200–400ppm.Testwheneverpool/spaisfilled.

LOWlevelsofhardnesscanbeverycorrosive.Remember,additionofanychemicalscanchangethelevelsofchlorine,pH,andtotalalkalinity.Itisrecommendedthatresidentialspawaterbechangedevery2to3monthstopreventwaterproblems.

Publicspasmayneedtohavethewaterchangedeveryweek,orevendaily,dependingonthebatherload.

Figure1

Page 9: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

9

WARNING:Ifyousmellgasintheapplianceareaornearthefloor(PROPANEISHEAVIERTHANAIRANDHENCESETTLESONTHEFLOOR),stopandfollowtheinstructionsonthefrontcoverofthismanual.Sincepropanecanaccumulateincon-finedareas,extracareshouldbetakenwhenlightingpropaneheaters.

ATTENTION:Donotusetheheaterbelow40°F(4°C)temperaturewithoutadequatetemperaturepro-tection.

WARNING:Donotingestalcoholordrugsduringuseorpriortousingpool,spa,orhottub.Ingestionofsuchintoxicantscancausedrowsiness,whichcanleadtounconsciousness,andsubsequentlyresultindrowning.

USING CHLORINATORS AND CHEMICAL FEEDERS:Followtheinstructionsprovidedwithanyautomaticormanualchlorinatorandchemicalfeeder.All

chemicalsmustbeintroducedanddilutedintothepoolorspawaterbeforebeingcirculatedthroughtheheater.Donotplacechlorinetabletsorbrominesticksdirectlyintotheskimmer.Highchemicalconcentra-tionsmayresultwhenthepumpisnotrunning.Highchemicalconcentrationswillcauseveryrapidcorrosionoftheheatexchanger.ThisdamagewillnotbecoveredbytheHaywardwarranty.

HEATER OPERATION:Fulllightingandshutdowninstructionsareincludedonthelighting&operatinginstructionslabelaffixed

totheinsideofthefrontaccesspanel.SeeFigure2forthelocationofthislabelandthekeypad.SeeFigure3forthelabel.

Lighting&shutdownlabelislocatedontheinsideofthefront accesspanel

Removethese(4)screwstoremovethefrontaccesspane

Keypad

Figure2:Keypadandlabellocations

Page 10: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

10

Figure3:Lighting&OperatingInstructionslabel

Page 11: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

11

KEYPAD INPUTSThecontrolacceptsuserinputsviathekeypadonthefrontpanel.1. Whenchangingthemodefrom“STANDBY”toeither“SPA”or“POOL”theremaybeuptoa10-

seconddelayfortheblowerfantobeginrunning.Thecontrolperformsaninternalself-testandthenverifiesthattheblowervacuumswitchcontactsareopenbeforeenergizingtheblower.

2. Itisnormalfortheheatertodisplaya1-to2-seconddelayinrespondingtoanykeypadinput.3. Itisnormalfortheheatertodisplayuptoa5-seconddelaywhenthekeypadisusedtoresetthecon-

troltoclearanerrorcode.4. Thecontrolwillacceptamodechangeduringlockoutafter5seconds.Thecontrolwillcontinueto

displaytheerrorcodeandremaininlockoutuntilitisreset.Atresetthecontrolwillgotothelastsavedmode.

OPERATION: SET POINT ADjUSTMENT:Thesetpointtemperatureisdisplayedbypressingthe“UP”or“DOWN”buttonswhilein“POOL”or

“SPA”mode.Thesetpointwillblinkwhileitisdisplayed.Furtherpressingofthe“UP”or“DOWN”buttonswilladjustthesetpointtemperatureupordownasdesired.Thesetpointrangeisbetween65°F(18°C)and104°F(40°C).

FAHRENHEIT vERSUS CELSIUS:ThetemperaturecanbedisplayedinFahrenheitorCelsius.TOchangethedisplay,usethe“MODE”but-

tontoplacetheheaterin“STANDBY”.Thenpressandholdthe“UP”and“DOWN”buttonsuntilthedisplayshowsthe°F/°Cselection.Pressthe“DOWN”buttontotogglebetweenselections.Toaccepttheselection,pressthe“MODE”button.Iftheuserdoesnotact,theselectionwillbeautomaticallyacceptedafter60sec-onds.

WINTERIzATION:Inmoderateclimates,theheatercancontinuetooperateduringshort-termcoldspells.Donotusethe

heatertomaintainthewatertemperaturejustabovefreezingorforfreezeprotection.Caremustbetakentoavoidfreeze-upintheheater.Whenitisusedduringfreezingweather,thepumpmustruncontinuously.Theheaterisnotwarrantedagainstfreeze-ups.Inregionswherefreezingtemperaturesareencountered,allwatermustbedrainedfromtheheaterwhenitisoutofservice,topreventdamagetotheheaterandpiping.Drain-ingtheheatexchangerisrecommendedaspartoftheseason’sshutdownprocedures.

Figure4:Keypad KeypadImput

Page 12: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

12

SPRING START-UP – CONSULT A PROFESSIONAL:1. Inspectandcleantheheater,beingsuretheheaterisfreeofleavesanddebrispriortostartup.2. Besureinletandoutletpipingareproperlyattachedtotheheaterandthedrainvalveisclosed.3. Turnthefiltrationsystempump“ON”andallowthesystemtorunlongenoughtopurgealltheair

fromthelines.4. Turnthegassupplytotheheater“ON”.5. Setthetemperaturecontrolusingthekeypadto“POOL”or“SPA”andadjustthesetpointtothe

desiredtemperaturesetting.6. Ifoperatingdifficultiesareencountered,contactaqualifiedservicecompanyforassistance.

ERROR CODES: Figure5liststheerrorcodesthatmaybedisplayedontheheaterdisplayboard. Contactaqualifiedservicecompanyforassistance.

Code Description Information

bDInternalfault/power-uperror

Oninitialtrialforignition.Automaticresetisimmediateoncethegasvalverelaycheckresultsareacceptable.

bDGasvalvesensedas“ON”error

Ifvalveisopenwhenitshouldbeclosedtheheaterwillshutdownandgointolockout.Blowerwilloperateuntilerrorconditioniscorrected.Automaticrestart2minutesaftererroriscorrected.

bDGasvalvesensedas“OFF”error

Ifvalveisclosedbutflameissensedtheblowerwillrunfor5sthenstartanewignitionsequence.Iferroroccurs10timesduringacallforheatthecontrolwillgointolockout.Automaticresetis60minutes.

bD Dataretrievalerror Ifcontrolinputdataiscorruptedtheheaterwillshutdownandgointolockout.

HFFlamepresentwithgasvalve“OFF”error

Ifflameissensedwiththegasvalveoffthecontrolwillgointolockout.Theblowerwillrununtilerrorconditioniscorrected.Whencorrected,controlwillrunblowerfor5sthenautomaticallyrestartafter2minutes.

PFElectricalsupplywiringerror

Thiscodewilldisplayif120Vpolarityisreversed,lowvoltageisdetected,orifthegroundpathisnotsufficient.Resetisimmediateaftererroriscorrected.

AOProverswitchopenerror

Iftheblowerproverswitchdoesnotcloseaftertheblowerstartsthecontrolwillstoptheignitiontrialgointolockout.Theblowerwillcontinuetorun.Automat-icresetisimmediateaftertheswitchcloses.

AO

Proverswitchopenwhenexpectedclosederror

Iftheblowerproverswitchopensunexpectedlyduringoperationthecontrolwillshutdownandattempttore-light.Iftheswitchdoesnotcloseaftertheblowerstartsthecontrolwillgointolockoutwiththeblowerrunning.Automaticresetisimmediateaftererroriscorrected.

Figure5:ERROR CODES

Page 13: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

13

AOProverswitchopendur-ingpost-purgeerror

Iftheblowerproverswitchopensduringthepost-purgecycle(heaterisnotfir-ing)thecontrolwilldisplaytheerrorcode.Thepost-purgecyclewillbecom-pletedoncetheblowerproverswitchcloses.

ACProverswitchclosedwhenexpectedopenerror

Iftheblowerproverswitchisclosedbeforeblowerstart-upthecontrolwillnotstarttheblower.Automaticresetisimmediatewhentheswitchopens.

IOIgniteropenerror Ifthecontrolisnotinlockoutandsensesthattheignitercircuitisopenwhen

theblowerisrunningthecontrolwillturnofftheblowerandgointolockout.Automaticrestart2min.aftererroriscorrected.

SF

Thermistorerror Anexcessivetemperaturedifferencebetweenthetwothermistors(5°Formore)oran“outofbounds”conditiononbothsensors(lessthan10°Forgreaterthan180°F)willresultintheerrorcode.Automaticrestartis2minutesaftertheerroriscorrected.

HSExcessivewatertemperatureerror

Ifwatertemperatureexceeds105°Ftheheaterwillshutdownandgointolock-out.Automaticrestartis2minutesafterwatertemp.dropsbelow105°F.

HERapidwatertemperaturerise

Ifwatertemperaturerisestoorapidlytheheaterwillshutdownandgointolock-out.Automaticrestartisafter2minutes.Afterthethirdoccurrenceinthesamecallforheattheheaterwilllockout.

SbKeypadbuttonstuckclosederror

Ifoneofthekeypadbuttonsisclosed(orpressed)formorethan30stheerrorcodewillbedisplayedbutthecontrolwillcontinuetofunction.Theerrorcodewillbeclearedwhentheconditioniscorrected.

IFIgnitionfailureerror Ifthecontrolexceedsthemaximumnumberofignitionretriesorrecyclesthe

heaterwillshutdownandgointolockout.Automaticresetis60minutes.

CE

Communicationerror Ifcommunicationbetweentheignitionboardandthedisplayboardisnotestab-lishedwithin3sofpower-upanerrorwillbedisplayed.Aftercommunicationisestablished,ifitislostfor30s,theerrorwillbedisplayed.Theerrorcodewillbecleareduponavaliddataexchangebetweenboards.

LOLimitstringopenerror Ifthelimitstringopenstheheatershutsdownandgoesintolockout.Automatic

restartis2minutesaftertheerrorconditioniscorrectedandthelimitstringcloses.

EE EEPROMerror Anerrorwasdetectedintheignitioncontrolcircuitboard.

Figure5:ERROR CODES(continued)

Page 14: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

14 HAYWARD PooL HeAteR CeRtIFICAte oF LIMIteD WARRAntY

Limitedheaterwarranty:TERMSANDCOVERAGE:Wewarrantourpoolheatertobefreefromdefectsinworkmanshipandmateri-alsundernormaluseandservice.PursuanttothiswarrantyandsubjecttotheConditionsandExceptionsindicatedbelow: 1.Wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)with

theprevailingcomparablemodel,or,atouroption,repairanypool/spaheaterthatleaksundernor-maluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.

2.Inaddition,wewillreplace(costoffreight,installation,costoffuel,andservicelaboratuser’sexpense)or,atouroption,repairanypartorpartsofthepool/spaheaterwhichmalfunctionsundernormaluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.

LIMITATION ON IMPLIED WARRANTIES:WEARENOTLIABLEFORANYCONSEQUENTIALDAMAGESFORBREACHOFANYWRITTENORIMPLIEDWARRANTYOFTHISPRODUCT.Im-pliedwarranties,includingtheWARRANTYofMERCHANTABILITYandallotherimpliedwarrantiesthatmayarisefromcourseofdealingorusageoftradeimposedonthesaleofthisheaterunderlawsofthestatearelimitedindurationtothetermofone(1)yearforallusers.Therearenowarrantieswhichextendbeyondthedescriptiononthefacehereof.Weshallnotinanyeventbeheldliableforanyspecial,indirect,orconse-quentialdamages.

eXPense oF DeLIVeRY AnD InstALLAtIon:Eachpoolheaterorreplacementparttobefurnishedunderthiswarrantyshallbefurnishedatournearest

distributioncenter.Weshallnotpay,norberesponsibleforshippingordeliverychargestotheplaceofinstal-lation,norforlaborchargesorothercostsofremovalorinstallation.Everydefectiveheaterorpartreplacedunderthiswarrantyshallbecomeourproperty,andassuch,mustbereturnedtoourdistributioncenterwithtransportationchargespaidbytheuser.Anyreplacementpoolheaterfurnishedunderthiswarrantyshallre-maininwarrantyonlyfortheunexpiredportionofthiswarranty.

ConDItIons AnD eXCePtIons:Thiswarrantyappliesonlytothepool/spaatitsoriginalplaceofinstallationandonlyfortheoriginal

owner.Itdoesnotapplyifthepoolheaterisinstalledinviolationofanyapplicablecodeorordinance,orisnotinstalled,operatedandmaintainedinaccordancewithourinstructions,orismisused,damagedbyac-cident,weather,actofGod,freezing,watervoidand/orexcesspressure,alteredordisconnected.Itdoesnotapplywithrespectto: 1.AheaternotequippedwithCertifiedC.S.A.limitcontrolsorequivalentpressurereliefvalve. 2.Aheateroperatedwithsettingsinexcessof,and/orwithfuelnotconformingtothoseshownonrat-

ingplate; 3.Aheateronwhichtheserialnumbershavebeenaltered,defaced,orremoved. 4.Leaksarisingfromdefectiveinstallation; 5.Productionofnoise,odors,ordiscolored(rusty,etc.)water; 6.Leakagesubstantiallycontributedtobysediment,limeprecipitateand/orhigherthannormaldis-

solvedsolids(pHabove7.8)inthetank,coppertubes,orwaterways; 7.Leakagecausedsubstantiallycontributedtobycorrosiveelementsintheatmosphere(suchasthe

storageofchlorineorotherchemicals); 8.Leakagecausedsubstantiallyorcontributedtobycorrosivepoolwaterinanacidcondition(pH

below7.2); 9.Damagecausedsubstantiallyorcontributedtobyanexternalsourceofenergy; 10.Apool/spaheaterisawatercontainingdevice.Leakageofwaterfromthisdevicecanbeexpected

atsometimeduetomalfunctionorthelimitations

Page 15: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Pomona, CA Clemmons, NC Nashville, TNTel: 908-351-5400 www.haywardpool.com

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

15

oftheservicelifeofvariouscomponents.Donotinstallthisproductwheresuchleakagecancausedamage.MANUFACTURERISNOTRESPONSIBLEORLIABLEFORANYCOSTSINCURREDBYSUCHDAMAGE.

IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGETO SURROUNDING AREA OR PROPERTYCAUSED BY LEAKAGE OR MALFUNCTION.

HoW to CLAIM UnDeR tHIs WARRAntY: Theoriginalowner,upondiscoveringthedefect,mustpresenttheattachedcompletedwarrantyclaimcard

withproofofpurchaseeithertothedealerornotifytheCompanyinwritingateitheraddress:

HAYWARD PooL PRoDUCts, InC.620 DIvISIOn St.ELIzAbEth, nJ 07207

oR

HAYWARD PooL PRoDUCts, InC.2875 POMOnA bOULEvArDPOMOnA, CA 91768

Uponreceiptofsuchnotificationweshalldecidewhethertorepairsuchpartsorreplaceanypoolheater,reservingatalltimestherighttoinspectinordertoverifyanyclaimeddefect.Wealsoreservetherighttohaveourrepresentativesmakeanyinspections,repairs,ortofurnishreplacements.ThiswarrantyisintendedasalegallybindingobligationoftheCompany,enforceableinthecourts.Thiswarrantymaygiveyouspe-cificlegalrightswhichmayvaryfromstatetostate.

LIMItAtIon on LIABILItY: Allintendedrepresentationshavebeenexpresslysetforthinthisdocument.Thiswarrantymaynotbe

extendedbyoraloranyotheradditionalrepresentations,writtensalesinformation,drawings,orothermal-function,isstrictlylimitedtorepairorreplacementofthedefectiveheaterorpart,asprovidedhereinandtheCompanyisnotresponsiblehereunderforincidentalorconsequentialorincidentalcostsordamages.Thecompanyneitherassumes,norauthorizesanypersonorfirmtoassumeforus,anyfurtherliabilityorobligationinconnectionwiththesale,installation,use,maintenance,orexistenceoftheheater.SAFETYWARNING:Poolheatersareheatproducingappliancesandtoavoiddamageorinjuryintheeventofpos-sibleoverheatingoftheouterjacket(1)nomaterialsshouldbestoredagainstthejacketand(2)careshouldbetakentoavoidunnecessarycontact(especiallybychildren)withthejacket.Whenlightingagasheater,thelightinginstructionsmustbefollowedexactlytoprevent“flashback”ofexcessgasintheheater.Electronicignitionheatersandelectricheatersmusthavethepowershutoffwhenmakingadjustmentsto,servicing,orcomingintocontactwiththeheater.UNDERNOCIRCUMSTANCESSHOULDFLAMMABLEMATERI-ALS,SUCHASGASOLINEORPAINTTHINNERS,BEUSEDORSTOREDINTHEVICINITYOFTHEHEATERORINANYLOCATIONFROMWHICHFUMESCOULDREACHTHEHEATER.Foryourcomfort,enjoymentandsafety,pleasereadtheenclosedoperatinginstructionscarefully.

Page 16: Hayward Pool And Spa/Hot Tub Heaters H150FD, … and spa/hot tub heaters h150fd, h200fd, h250fd, h300fd, h350fd & h400fd models owner’s manual for your safety ... 1301640701 rev

Hayward Pool Products, Inc.620 Division St.Elizabeth, nJ 07207

Hayward Pool Products, Inc.2875 Pomona boulevardPomona, CA 91768

Hayward Pool Products, Inc.2880 Plymouth DriveOakville, Ontario L6h 5r4

Hayward S.A.zoming de Jumetb6040 Jumet, belgique

© 2004 Hayward Imprimé aux U.S.A.