9
Grounds/Jumpers Chance Grounding Clamps Catalog No. C600-1959* T600-0465* T600-0466* T600-0790* C600-2271* C600-2232** C600-2231** G3363-1** G3363-2** C600-1783** Continuous Current (AMPS) 200 400 400 400 400 400 400 Fault Current - 15 Cycles (AMPS) 21,500 43,000 43,000 43,000 27,000 27,000 43,000 Fault Current - 30 Cycles (AMPS) 15,000 30,000 30,000 30,000 20,000 20,000 30,000 Recommended Torque (in.-lbs.) 200 350 250 250 250 250 300 Main Line Range - Max 477 kcmil ACSR (0.814”) 1033 kcmil ACSR (1.25”) 1-1/2” Angles 1-1/2” Flat 1-1/2” Angles 1-1/2” Flat 1-1/2” Angles 1-1/2” Flat 1-1/2” Angles 1-1/2” Flat 3/4” x 5” Angles or Flats 5/8” Rod Main Line Range - Min #6 Sol. Cu. (0.162”) #6 Sol. Cu. (0.162”) 1/8” 1/8” 1/8” 1/8” 1/8” Jumper Range - Max 1/0 Grd. Cable w/Threaded Stud 4/0 Grd. Cable w/Threaded Stud 4/0 Grd. Cable w/Threaded Stud 2/0 Grd. Cable w/Plain Plug 2/0 Grd. Cable w/Plain Plug 2/0 Grd. Cable w/ Plain Plug 4/0 Grd. Cable w/Threaded Stud Jumper Range - Min #2 Grd. Cable w/Threaded Stud #2 Grd. Cable w/Threaded Stud #2 Grd. Cable w/Threaded Stud #2 Grd. Cable w/Threaded Stud #2 Grd. Cable w/Plain Plug #2 Grd. Ca- ble w/Plain Plug #2 Grd. Cable w/Threaded Stud ASTM Designation Type I Class A Grade 2 Type I Class A Grade 5 Type I Class B Grade 5 Type III Class B Grade 5 Type I Class B Grade 3 Type III Class B Grade 3 Type III Class B Grade 5 * C-Type Clamps ** Tower and Flat-Face Clamps C600-2271 T600-465 C600-1959 C600-1783 C600-2231 C600-2232 G3363-1 G3363-2 85

GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

Gro

unds

/Jum

pers

Chance Grounding ClampsCatalog No.

C600-1959*T600-0465*T600-0466*T600-0790*

C600-2271* C600-2232** C600-2231** G3363-1** G3363-2** C600-1783**

Continuous Current (AMPS) 200 400 400 400 400 400 400

Fault Current - 15 Cycles (AMPS) 21,500 43,000 43,000 43,000 27,000 27,000 43,000

Fault Current - 30 Cycles (AMPS) 15,000 30,000 30,000 30,000 20,000 20,000 30,000

Recommended Torque (in.-lbs.) 200 350 250 250 250 250 300

Main Line Range - Max

477 kcmilACSR

(0.814”)

1033 kcmilACSR(1.25”)

1-1/2” Angles1-1/2” Flat

1-1/2” Angles1-1/2”Flat

1-1/2” Angles1-1/2” Flat

1-1/2” Angles1-1/2” Flat

3/4” x 5”Angles or

Flats5/8” Rod

Main Line Range - Min #6 Sol. Cu.(0.162”)

#6 Sol. Cu.(0.162”) 1/8” 1/8” 1/8” 1/8” 1/8”

Jumper Range - Max

1/0 Grd. Cable

w/Threaded Stud

4/0 Grd. Cable

w/Threaded Stud

4/0 Grd. Cable w/Threaded

Stud

2/0 Grd. Cable w/Plain

Plug

2/0 Grd. Cable w/Plain

Plug

2/0 Grd. Cable w/

Plain Plug

4/0 Grd. Cable w/Threaded

Stud

Jumper Range - Min#2 Grd. Cable w/Threaded

Stud

#2 Grd. Cable

w/Threaded Stud

#2 Grd. Cable

w/Threaded Stud

#2 Grd. Cable

w/Threaded Stud

#2 Grd. Cable w/Plain

Plug

#2 Grd. Ca-ble w/Plain

Plug

#2 Grd. Cable

w/Threaded Stud

ASTM DesignationType I

Class AGrade 2

Type IClass AGrade 5

Type IClass BGrade 5

Type IIIClass BGrade 5

Type IClass BGrade 3

Type IIIClass BGrade 3

Type IIIClass BGrade 5

* C-Type Clamps** Tower and Flat-Face Clamps

C600-2271 T600-465

C600-1959

C600-1783C600-2231

C600-2232G3363-1 G3363-2

85

Page 2: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

rounds\Jumpers

Hastings C-Head Grounding Clamps

Catalog No. Description Main Line

Range Max.

Main Line Range Min.

Max. Jumper Cable

Max. Fault Current Rat-

ing

Min. Installation Torque

Weight (lbs.)

21070Single Grd.

ClampBronze Alloy

2.88 OD Cable or Bus

6 Solid.16 Dia.

4/0 Str. w/Ferrule

43,000 Amps15 Cycles

30,000 Amps30 Cycles

275 Inch Lbs. 3.25

21552Single Grd.

ClampBronze Alloy

500 MCM.813 Dia.

8 Solid.128 Dia.

4/0 Str. w/Ferrule

43,000 Amps15 Cycles

30,000 Amps30 Cycles

275 Inch Lbs. 1.4

21307Single Grd.

ClampBronze Alloy

1.033 MCM ACSR

1.25 Dia.

6 Solid.16 Dia.

4/0 Str. w/Ferrule

43,000 Amps15 Cycles

30,000 Amps30 Cycles

275 Inch Lbs. 2.25

13190-1 Hanger Stud, fits above Catalog No.’s 21070, 21552, and 21307 .4

Hastings Tower and Flat-Face Grounding Clamps

Catalog No. Description Max. Jaw

Opening

Max. Jumper Cable

Max. Fault Current Rating

Min. Installation Torque

Weight (lbs.)

9123CC

Single Grd. Clamp w/Tee

HandleBronze Alloy

1.5” 4/0 Str. w/Ferrule

43,000 Amps, 15 Cycles30,000 Amps, 30 Cycles 200 Inch Lbs. 3.5

9153CC

Single Grd. Clamp w/Eye

ScrewBronze Alloy

1.5” 4/0 Str. w/Ferrule

43,000 Amps, 15 Cycles30,000 Amps, 30 Cycles 200 Inch Lbs. 3.5

21571

Single Grd. Clamp w/Eye

ScrewBronze Alloy

1.5” 4/0 Str. 43,000 Amps, 15 Cycles30,000 Amps, 30 Cycles 276 Inch Lbs. 2.2

21608

Single Grd. Clamp w/Tee

HandleBronze Alloy

1.5” 4/0 Str. 43,000 Amps, 15 Cycles30,000 Amps, 30 Cycles 276 Inch Lbs. 2.4

21070 21552 21307

9123CC 9153CC 21571 21608 86

Page 3: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

roun

ds/J

umpe

rs

Hastings Grounding Cable FerrulesCatalog No. Size AWG Alcoa Die Burndy Die Kearney Die

11656* #2 B71AH - -

11657* 1/0 B72AH U241 510

11658* 2/0 B73AH U243 9/16

11660* 4/0 B74AH U694 11/16

12998** #2 B73AH U165 9/16

12999** 1/0 B73AH U166 5/8-1

13000** 2/0 B74AH U166 11/16

13001** 4/0 - U168 15/16

* Compression Ferrules for Bolted Type Terminals** Compression Ferrules for 5/8”-11 NC Threaded Type Terminals

11656

12998

Fault Current Rating Table for Grounding Cable

Ground Cable Size AWGRatings in Amperes Symmetrical RMS 60 Hertz

15 Cycles 30 Cycles#2 14,500 Amps 10,000 Amps

1/0 21,000 Amps 15,000 Amps

2/0 27,000 Amps 20,000 Amps

4/0 43,000 Amps 30,000 Amps

Salisbury Grounding Cable

Color Catalog No. Size

Strand Dia. (in.)

Jacket (in.)

Short Circuit WithstandAMPS, RMS, 60 Hz

Continuous Current

AMPS, RMS, 60 Hz

Wt./1000 ft. (lbs.)

15 Cycles 30 Cycles

Yellow 2136 #2-665W .35 .5 14500 10000 200 282

Yellow 2137 1/0-1064W .45 .62 21000 15000 250 488

Yellow 2138 2/0-1330W .49 .65 27000 20000 300 537

Yellow 2139 4/0-2109W .62 .83 43000 30000 400 836

Black 2636 #2-665W .35 .47 14500 10000 200 263

Black 2637 1/0-1064W .45 .58 21000 15000 250 404

Black 2638 2/0-1330W .49 .63 27000 20000 300 497

Black 2649 3/0-1672W .55 .72 36000 25000 350 680

Black 2639 4/0-2109W .62 .78 43000 30000 400 770

Clear 2128 #2-665W .35 .53 14500 10000 200 289

Clear 2129 1/0-1064W .45 .64 21000 15000 250 520

Clear 2133 2/0-1330W .49 .7 27000 20000 300 546

Clear 2288 4/0-2109W .62 .84 43000 30000 400 841

87

Page 4: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

rounds\Jumpers

Salisbury Non-Locking FerrulesCatalog No.

(Pair) Cable Size Strand Die Codes T&B

Jacket Die Codes T&B

2012* #2-15 kV ERP 66 106

2013* 1/0-15 kV ERP 66 106

2014* 2/0-15 kV ERP 66 106

2015* 4-0-15 kV ERP 66 106

21353* 1/0-25 kV 66 112

21354* 2/0-25 kV 66 112

21355* 1/0-35 kV 66 125

21356* 2/0-35 kV 66 125

2022** #2 50 --

2023** 1/0 50 --

2024** 2/0 60 --

2025** 4/0 66 --

* Shrouded** Unshrouded

ShroudedUnshrouded

Hastings Standard FerrulesCatalog No. Cable Size Alcoa Die Burndy Die Kearney Die

13100 #2 B73AH U165 9/1613101 1/0 B73AH U166 5/8-113102 2/0 B74AH U166 11/1613103 4/0 N/A U168 15/16

Chance Shrouded Plain Copper Ferrules

Catalog No. (1 each)

Burndy Die No. or Equivalent Cable

Size, AWGSection A Section B

C600-2630 U165 U166 #2

C600-2631 U165 U168 1/0

C600-2632 U165 U-L 2/0

C600-2633 U166 U-L 4/0

Chance Shrouded Threaded Copper Ferrules

Catalog No. (1 each)

Burndy Die No. or Equivalent Cable

Size, AWGSection A Section B

C600-2622 U165 U166 #2

C600-2623 U165 U168 1/0

C600-2624 U165 U-L 2/0

C600-2625 U166 U-L 4/0

Chance Unshrouded Plain Copper FerrulesCatalog No.

(1 each)Burndy Die No. or Equivalent Cable Size, AWG

C600-2614 U165 #2

C600-2615 U165 1/0

C600-2616 U165 2/0

C600-2617 U166 4/0

Chance Unshrouded Threaded Copper Fer-rules

Catalog No. (1 each)

Burndy Die No. or Equivalent Cable Size, AWG

C600-2606 U165 #2

C600-2607 U165 1/0

C600-2608 U165 2/0

C600-2609 U166 4/0

88

Page 5: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

roun

ds/J

umpe

rs

Chance Underground Distribution Grounding Sets

Catalog No. ApplicationT600-3091* 15 kV

T600-3092* 25 kV & 35 kV small interface

C600-0729** 15 kV

T600-2131** 25 kV & 35 kV small interface

C600-1927** 35 kV large interface

C600-3102*** 15 kV

C600-3103*** 25 kV & 35 kV small interface

* Grounded Parking Bushing Sets for Single-Phase or Three-Phase Switches and Transformers** Grounding Elbow Sets for Single-Phase or Three-Phase Switches and Transformers*** Three-Phase Grounding Elbow Sets for Switches and Transformers

Hastings Underground Distribution Grounding SetsCatalog No. Description

6716* Transformer Grounding Set w/6 Ft. 1/0 Copper Grd. Cable. Includes Flat Jaw Clamp Cat. No. 9153

6717* Three-Phase Grounding Set w/6 Ft. 1/0 Copper Grd. Cables, Terminal Block and Flat Jaw Ground Clamp. Rated 10,000 Amps for 10 cycles.

6776** Transformer Grounding Set w/6 Ft. 1/0 Copper Grd. Cable. Includes Flat Jaw Clamp Cat. No. 9153

6777** Three-Phase Grounding Set w/6 Ft. 1/0 Copper Grd. Cables, Terminal Block and Flat Jaw Ground Clamp Cat. No. 9153.

6778*** Transformer Grounding Set w/6 Ft. 1/0 Copper Grd. Cable and Flat Jaw Ground Clamp Cat. No. 9153.

6779*** Three-Phase Grounding Set w/6 Ft. 1/0 Copper Grd. Cables, Terminal Block and Flat Jaw Ground Clamp Cat. No. 9153.

* 15KV ** 25KV *** 35KV

6716

6717

Hastings Grounded Parking Stand Assemblies

Catalog No. Description Weight (lbs.) Carrying/Storage Case

6771 15KV Grounded Parking Stand w/Threaded Ferrule 5.5 01-4007 or 7254

6772 15KV Grounded Parking Stand w/Plug Terminal Ferrule 5.5 01-4007 or 7254

6773 25KV Grounded Parking Stand w/Threaded Ferrule 6 01-4007 or 7254

6774 25KV Grounded Parking Stand w/Plug Terminal Ferrule 6 01-4007 or 7254

6771

89

Page 6: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

rounds\Jumpers

Jumper Cable - 15 kVCatalog No. Description

2754 Salisbury Insulated Jumper Cable, #2

12198 Hastings Insulated Jumper Cable, #2

2755 Salisbury Insulated Jumper Cable, 1/0

12199 Hastings Insulated Jumper Cable, 1/0

2756 Salisbury Insulated Jumper Cable, 2/0

12200 Hastings Insulated Jumper Cable, 2/0

2757 Salisbury Insulated Jumper Cable, 4/0

12201 Hastings Insulated Jumper Cable, 4/0

Jumper Cable - 25 kVCatalog No. Description

21060 Salisbury Insulated Jumper Cable, 2/0

6874 Hastings Insulated Jumper Cable, 2/0

Jumper Cable - 35 kVCatalog No. Description

2059 Salisbury Insulated Jumper Cable, 1/0

4370 Salisbury Insulated Jumper Cable, 2/0

6859 Hastings Insulated Jumper Cable, 1/0

90

Page 7: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

roun

ds/J

umpe

rs

Jumper Clamps - Medium RangeCatalog

No. Description Max Main Line Range

Min Main Line Range

Max Jumper Cable Range

Min Jumper Cable Range

13004-2 Jumper Clamp, Pair 556.5 MCM or 477 ACSR

6 Solid .162 Dia. 4/0 Str. 15KV 2 Str.

13004 Jumper Clamp, Single 556.5 MCM or 477 ACSR

6 Solid .162 Dia. 4/0 Str. 15KV 2 Str.

Jumper Clamps - Large RangeCatalog

No. Description Max Main Line Range

Min Main Line Range

Max Jumper Cable Range

Min Jumper Cable Range

11000-2 Jumper Clamp, Pair 954 ACSR36/1

6 Solid .162 Dia.

4/0 Str. 15KV1/0 Str. 35KV 2 Str.

11000 Jumper Clamp, Single 954 ACSR36/1

6 Solid .162 Dia.

4/0 Str. 15KV1/0 Str. 35KV 2 Str.

Hastings Jumper Clamps

Salisbury Jumper Clamps

Jumper Clamps - Sure-lok™ (Salcor Handle)Catalog

No. Main Line Range Max Amps Continuous Rating OAL Length(in.)

2261 477 MCM (.9”-.162”) 400 36kV 0-0

21kV 0-GRD

11.5

2271 954 MCM (1.25”-.162”) 400 11.5

Jumper Clamps - Sure-lok™ (Clear Plastic Handle)Catalog

No. Main Line Range Max Amps Continuous Rating OAL Length(in.)

1786 477 MCM (.9”-.162”) 400 36kV 0-0

21kV 0-GRD

11.5

2116 954 MCM (1.25”-.162”) 400 11.5

91

Page 8: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

rounds\Jumpers

Jumper Clamps - Salcor ClampsCatalog

No. Main Line Range Max Amps Continuous Rating OAL Length

(in.)

2260 477 MCM (.9”-.162”) 400 36kV 0-0

21kV 0-GRD

11.5

2270 954 MCM (1.25”-.162”) 400 11.5

Salisbury Jumper Clamps (continued)

2260 2270

Jumper Clamps - Clear Plastic ClampsCatalog

No. Main Line Range Max Amps Continuous Rating OAL Length

(in.)

1785 477 MCM (.9”-.162”) 400 36kV 0-0

21kV 0-GRD

11.5

2115 954 MCM (1.25”-.162”) 400 11.5

1785 2115

Jumper Clamps - FPR ClampsCatalog

No. Main Line Range Max Amps Continuous Rating OAL Length

(in.)

1610 954 MCM (1.25”-.162”) 40036kV 0-0

21kV 0-GRD11

1610

92

Page 9: GroundJumperep.yimg.com/ty/cdn/yhst-10358334955214/groundjumper.pdf · Hastings Underground Distribution Grounding Sets Catalog No. Description 6716* Transformer Grounding Set w/6

(800)844-3057 www.redbudsupply.netG

roun

ds/J

umpe

rs

Jumper Clamps - Connector Link

Catalog No. Max Amps Continuous

OAL Length(in.)

2750 400 11.5

Salisbury Jumper Clamps (continued)

Jumper Equipment - Load-PickUp Tool

Catalog No. Description Cable Length (Ft.)

15kV Cable Size

C403-1631 Load Pick-Up Tool ONLY --- ---

C403-1557 Load Pick-Up Tool Set 10 #2

C403-1558 Load Pick-Up Tool Set 12 #2

C403-1559 Load Pick-Up Tool Set 10 1/0

C403-1560 Load Pick-Up Tool Set 12 1/0

C403-1631C403-1557

Jumper Equipment - Load-PickUp Tool

Catalog No. Description6600 Load Pick-Up Tool

Chance Load-Pickup Tools

Hastings Load-Pickup Tools

To order the factory-assembled Load Pick-Up Tool set:

1. Select Jumper Clamp 11000, 13768, or Ground Clamp.

2. Select Jumper Cable, 15KV or 25KV.

3. Select Cable Length

4. Select appropriate ferrule connector.

5. Your catalog number for the factory-assembled Load Pick-Up tool will be designated by your string of numbers. (ex. 6600-13768-6874-12 (13102)