3
NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side A – 02-15 Fabric-Attached Storage (FAS), V-Series, and Storage Acceleration (SA) Controllers Model FAS/V6280 SA620 FAS/V6240 FAS/V6210 FAS/V6080 SA600 FAS/V6040 FAS/V3270 SA320 1 FAS/V3240 1 FAS/V3210 FAS/V3170 FAS/V3160 FAS/V31 Front View Max Capacity 2 (7.3.x/8.0.x/8.1.x) -/4320TB 3 / 4320TB 3 -/4320TB 3 / 4320TB 3 -/3600TB 3 / 3600TB 3 1176TB/ 3528TB 3 /3528TB 3 840TB/2520TB 3 /2520TB 3 960TB/2880TB 3 /2880TB 3 600TB/1800TB 3 /1800TB 3 240TB/720TB 3 /720TB 3 840TB/2520TB 3 /2520TB 3 672TB / 2016TB 3 /2016TB 3 420TB/1260 /1260TB Max Aggregate 4 (7.3.x/8.0.x/8.1.x) -/100TB/162TB -/100TB/162TB -/70TB/162TB 16TB/100TB/ 162TB 16TB/70TB/ 105TB 16TB/70TB/ 105TB 16TB/50TB/ 90TB 16TB/50TB/75TB 16TB/70TB/ 105TB 16TB/50TB/90TB 16TB/50TB/ Max FlexVol Size (7.3.x/8.0.x/8.1.x) -/100TB/100TB -/100TB/100TB -/70TB/70TB 16TB/100TB/ 100TB 16TB/70TB/70TB 16TB/70TB/70TB 16TB/50TB/50TB 16TB/50TB/50TB 16TB/70TB/70TB 16TB/50TB/50TB 16TB/50TB/ Max Shelves (DS2446/DS4243/DS14) 60/60/84 60/60/84 50/50/72 49/49/84 35/35/60 40/40/40 25/25/42 10/10/17 35/35/60 28/28/48 17.5/17.5 Max Drive Quantity 1440 1440 1200 1176 840 960 600 240 840 672 420 Ethernet (HA/Single) 4/2GbERJ45 8/410GbESFP+ 4/2GbERJ45 8/410GbESFP+ 4/2GbERJ45 8/410GbESFP+ 12/6 GbERJ45 12/6 GbERJ45 4/2 GbERJ45 4/2 GbERJ45 4/2 GbERJ45 4/2 GbERJ45 4/2 GbERJ45 4/2 GbERJ4 FC Ports (HA/Single) 8-32/4-16 8GbSFP+ 7 8-32/4-16 8GbSFP+ 7 8-16/4-8 8GbSFP+ 7 16/8 4GbSFP 16/8 4GbSFP 4/2 4GbSFP 4/2 4GbSFP 4/2 4GbSFP 8/4 4GbSFP 8/4 4GbSFP 8/4 4GbSFP SAS Ports (HA/Single) 0-24/0-12 6GbQSFP 8 0-24/0-12 6GbQSFP 8 0-8/0-4 6GbQSFP 8 - - 4/2 6GbQSFP 4/2 6GbQSFP 4/2 6GbQSFP - - - Please recycle after use. Feedback and questions can be sent to [email protected]

Hardware Universe-Controllers.pdf

Embed Size (px)

Citation preview

Page 1: Hardware Universe-Controllers.pdf

NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side A – 02-15-2012

Fabric-Attached Storage (FAS), V-Series, and Storage Acceleration (SA) Controllers

ModelFAS/V6280

SA620FAS/V6240 FAS/V6210

FAS/V6080

SA600FAS/V6040

FAS/V3270

SA3201FAS/V32401 FAS/V3210 FAS/V3170 FAS/V3160 FAS/V314

Front View

Max Capacity2

(7.3.x / 8.0.x / 8.1.x)

- / 4320TB3 /

4320TB3 - / 4320TB3 /

4320TB3 - / 3600TB3 /

3600TB31176TB / 3528TB3

/ 3528TB3840TB / 2520TB3

/ 2520TB3 960TB / 2880TB3

/ 2880TB3 600TB / 1800TB3

/ 1800TB3 240TB / 720TB3

/ 720TB3840TB / 2520TB3

/ 2520TB3672TB / 2016TB3

/ 2016TB3420TB / 1260TB

/ 1260TB

Max Aggregate4

(7.3.x / 8.0.x / 8.1.x) - / 100TB / 162TB - / 100TB / 162TB - / 70TB / 162TB

16TB / 100TB /

162TB

16TB / 70TB /

105TB

16TB / 70TB /

105TB

16TB / 50TB /

90TB16TB / 50TB / 75TB

16TB / 70TB /

105TB16TB / 50TB / 90TB 16TB / 50TB / 75TB

Max FlexVol Size

(7.3.x / 8.0.x / 8.1.x)- / 100TB / 100TB - / 100TB / 100TB - / 70TB / 70TB

16TB / 100TB /

100TB16TB / 70TB / 70TB 16TB / 70TB / 70TB 16TB / 50TB / 50TB 16TB / 50TB / 50TB 16TB / 70TB / 70TB 16TB / 50TB / 50TB 16TB / 50TB / 50TB

Max Shelves(DS2446 / DS4243 / DS14)

60 / 60 / 84 60 / 60 / 84 50 / 50 / 72 49 / 49 / 84 35 / 35 / 60 40 / 40 / 40 25 / 25 / 42 10 / 10 / 17 35 / 35 / 60 28 / 28 / 48 17.5 / 17.5 / 30

Max Drive

Quantity1440 1440 1200 1176 840 960 600 240 840 672 420

Ethernet

(HA / Single)

4 / 2 GbE RJ45

8 / 4 10GbE SFP+

4 / 2 GbE RJ45

8 / 4 10GbE SFP+

4 / 2 GbE RJ45

8 / 4 10GbE SFP+

12 / 6

GbE RJ45

12 / 6

GbE RJ45

4 / 2

GbE RJ45

4 / 2

GbE RJ45

4 / 2

GbE RJ45

4 / 2

GbE RJ45

4 / 2

GbE RJ45

4 / 2

GbE RJ45

FC Ports

(HA / Single)

8-32 / 4-16

8Gb SFP+78-32 / 4-16

8Gb SFP+78-16 / 4-8

8Gb SFP+716 / 8

4Gb SFP

16 / 8

4Gb SFP

4 / 2

4Gb SFP

4 / 2

4Gb SFP

4 / 2

4Gb SFP

8 / 4

4Gb SFP

8 / 4

4Gb SFP

8 / 4

4Gb SFP

SAS Ports

(HA / Single)

0-24 / 0-12

6Gb QSFP80-24 / 0-12

6Gb QSFP80-8 / 0-4

6Gb QSFP8- -

4 / 2

6Gb QSFP

4 / 2

6Gb QSFP

4 / 2

6Gb QSFP- - -

Please recycle after use. Feedback and questions can be sent to [email protected]

Page 2: Hardware Universe-Controllers.pdf

Depth: 29 in. (73.66 cm)

Please recycle after use. Feedback and questions can be sent to [email protected]

FAS/V6200 and SA620

(Single controller show)

3

4

5

6

LINK LINKLINK LINK

0a 0b 0c 0d

INT LNK

LNK ACT

LNK ACT

10

9

8

7 13

14

15

16

NVRAM8 adapter is placed in slot 2 in a FAS6200 series controller (as shown). FAS6210 model does not support IOXM.

Q

Q

Slot 3

Slot 6

Slot 5

Slot 4

Slot 13

Slot 16

Slot 14

Slot 15

Slot 7

Slot 10

Slot 9

Slot 8

Slot 1

Slot 11

Slot 12

+++++P +++

17.53 in. (44.52 cm)

10.2 in.

(25.86 cm)

A

B

1

2

DC AC

x2

2

KNLKNL

0a0b

e0a

e0b

e0c

e0d

KNL

0bP

FAS2240-2

17.6 in. (44.7 cm)

NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side B – 02-15-2012

KNLKNL

0a0b

e0a

e0b

e0c

e0d

KNLKNL

0a0b

e0a

e0b

e0c

e0d

Depth: 24 in. (61 cm)

FAS2240-4

17.7 in. (44.9 cm)

7 in.

(17.8 cm)

P

P

Expansion

PCIe

Gigabit Ethernet

RJ45

4Gb Fibre Channel

SFP

Serial-Attached SCSI

QSFP

Serial Console

RJ45

HA Interconnect

IB4X

Expansion

PCI-X

10 Gigabit Ethernet

SFP++

8Gb Fibre Channel

SFP++

Alternate Control Path

RJ45P

Remote Management

RJ45

HA Interconnect

QSFPQ

HA Interconnect

SFP++

0a 0b

LNK LNK

0c

0d e0b

e0a

c0b

c0a

3

4

FAS/V3200 & SA320

(Single contoller shown)

P

Slot 3

Slot 4

+

+

17.61 in. (44.7 cm)

FAS2040

P

P

17.6 in. (44.7 cm)

Page 3: Hardware Universe-Controllers.pdf

Depth: 29 in. (73.66 cm)

8 975 642 31

8 975 642 31

e0e e0f

d0ec0eb0ea0eRLM

0f h0g0e00b d0c0a0

2HI-POT2200VDC1

HI-POT2200VDC

REPLACE THIS ITEM

WITHIN 2 MINUTES OF

REMOVAL

REPLACE THIS ITEM

WITHIN 2 MINUTES OF

REMOVAL

PROPERLY SHUT DOWN SYSTEM BEFORE OPENING CHASSIS.

FAS/V6000 and SA600

(Single controller shown)

Slot 2

Slot 9

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

17.53 in. (44.52 cm)

10.32 in.

(26.21 cm)

FAS/V3100

17.73 in. (45 cm)

Please recycle after use. Feedback and questions can be sent to [email protected]

© 2012 NetApp, Inc.

change without notice. NetApp, the NetApp logo, Go

further, faster, Data ONTAP, NOW, SnapMirror and

MetroCluster are trademarks or registered trademarks

of NetApp, Inc. in the United States and/or other coun-

tries. All other brands or products are trademarks or

registered trademarks of their respective holders and

should be treated as such.

RC-0032-0212

This document is subject to change without notice.

ration Guide at

current information. NetApp employees and partners

can check the NetApp 1Stop site at

netapp1stop.com

should check with their account teams for updates.

This po

Enablement and Solutions Organization (TESO).

ACP – Alternate Control Path

BTU – British Thermal Unit

Cu – Copper Connector

FAS – Fabric-Attached Storage

FCP – Fibre Channel Protocol

FC – Fibre Channel

GbE – Gibabit Ethernet

HA – High Availability

HT – Hyper-Threading

IB4X

LUN – Logical Unit Number

NIC – Network Interface Card

NVRAM – Nonvolatile RAM

Op – Optical Connector

1

2 System capacity is calculated using base 10 arithmetic (1TB=1,000,000,000,000 bytes) and is derived based on the type, size, and

number of drives.

3 Max capacity shown can only be achieved using 3TB drives under Data ONTAP 8.0.2 or greater.

4 Maximum aggregate size is calculated using base 2 arithmetic (1TB = 240 bytes).

5 AC Power values shown are based on typical system values with 2 power supply units. Please refer to the Site Requirements Guide on

the NOW site for worst-case values.

6 Thermal disspation values shown are based on typcial system values. Please refere to the Site Requirements Guide on the NOW site for

worst-case thermal dissapation values.

7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on the vertical FC boards, all are considered as on-board ports, can be

set as target or initiators and support operation at 2, 4, or 8Gb speeds. Operation at 1Gb speeds is not supported.

8

9 100 LUNs from one array using one array LUN group. Combined LUN and NetApp disk can total 240 devices.

10 NVMEM on FAS2240 leverages portion of the 6GB of controller memory, resulting in ~5.25GB memory for Data ONTAP.

11 NVMEM allocation on the FAS2040 is 512MB with Data ONTAP 8.0 and higher and 256MB with Data ONTAP 7.3.x releases.

NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side C – 02-15-2012

Expansion

PCIe

Gigabit Ethernet

RJ45

4Gb Fibre Channel

SFP

Serial-Attached SCSI

QSFP

Serial Console

RJ45

HA Interconnect

IB4X

Expansion

PCI-X

10 Gigabit Ethernet

SFP++

8Gb Fibre Channel

SFP++

Alternate Control Path

RJ45P

Remote Management

RJ45

HA Interconnect

QSFPQ

HA Interconnect

SFP++