1 BROOKHAVEN SCIENCE ASSOCIATES Hard Coherent and XPCS Technique Discussion Session 1) What are the key scientific drivers? xpcs - dynamics of soft & biomolecular materials (membranes, nanoparticle suspensions, polymers, surface fluctuations of thin films); cdi - nonbiological nanostructures, nanocomposite materials, magnetic materials as well as materials defects, precipitates What experiments will NSLS-II enable that are not presently possible? xpcs - dynamics that occurs between 10msec-100nsec range; cdi - images of non-crystalline or finite-sized objects to 0.1 nm resolution 2) What technical capabilities will these require? (Beamlines, endstations, undulators…) high- straight with U19 undulator unless the U14 SCU becomes available, energy range of 7-20 keV although it was discussed whether lower (5KeV) energies gave more brightness, differentially pumped front-end, two parallel beamlines with two hutches for small-angle & wide-angle xpcs+cdi (side-deflecting mirrors), pink-beam and si monos, focusing optics, 2+4 type goniometer with 3m detector arm, hexapod sample manipulator, anomalous scattering or polarization fluctuations at resonance may be important but open issue whether the gains (phase retrieval or orientational fluctuations) justified higher heat loads of low energies. This would also require precise energy tunability. 3) Estimate of community size. depends on whether data acquistion and analysis software can be made user friendly 4) What detector requirements does this field have? fast pixel array detector with autocorrelators hard-wired to each pixel. Should design with 60m pixels in mind.Do these require R+D? yes 5) What software and computing infrastructure requirements are there? (Control, data acquisition, analysis) without proposed detector, xpcs will require data acquisition rates > gbytes/sec, cdi requires high performance computer for phase retrieval. Cdi also requires advances in phase retrieval techniques especillay for the study of extended samples.

Hard Coherent and XPCS Technique Discussion Session

  • Upload
    dunne

  • View
    40

  • Download
    1

Embed Size (px)

DESCRIPTION

Hard Coherent and XPCS Technique Discussion Session . - PowerPoint PPT Presentation

Citation preview

Page 1: Hard Coherent and XPCS Technique Discussion Session

1 BROOKHAVEN SCIENCE ASSOCIATES

Hard Coherent and XPCS Technique Discussion Session 1) What are the key scientific drivers? xpcs - dynamics of soft & biomolecular materials (membranes, nanoparticle

suspensions, polymers, surface fluctuations of thin films); cdi - nonbiological nanostructures, nanocomposite materials, magnetic materials as well as materials defects, precipitates What experiments will NSLS-II enable that are not presently possible? xpcs - dynamics that occurs between 10msec-100nsec range; cdi - images of non-crystalline or finite-sized objects to 0.1 nm resolution

2) What technical capabilities will these require? (Beamlines, endstations, undulators…) high- straight with U19 undulator unless the U14 SCU becomes available, energy range of 7-20 keV although it was discussed whether lower (5KeV) energies gave more brightness, differentially pumped front-end, two parallel beamlines with two hutches for small-angle & wide-angle xpcs+cdi (side-deflecting mirrors), pink-beam and si monos, focusing optics, 2+4 type goniometer with 3m detector arm, hexapod sample manipulator, anomalous scattering or polarization fluctuations at resonance may be important but open issue whether the gains (phase retrieval or orientational fluctuations) justified higher heat loads of low energies. This would also require precise energy tunability.

3) Estimate of community size. depends on whether data acquistion and analysis software can be made user friendly

4) What detector requirements does this field have? fast pixel array detector with autocorrelators hard-wired to each pixel. Should design with 60m pixels in mind.Do these require R+D? yes

5) What software and computing infrastructure requirements are there? (Control, data acquisition, analysis) without proposed detector, xpcs will require data acquisition rates > gbytes/sec, cdi requires high performance computer for phase retrieval. Cdi also requires advances in phase retrieval techniques especillay for the study of extended samples.

6) Any particular accelerator requirements? horiz.&vert. beam centroid stable to 0.2m, h&v beam divergence stable to 1.0&0.1rad for 100sec. to 2hrs.

7) Any particular conventional facility requirements? one beamline that extends into LOM.