Upload
others
View
9
Download
0
Embed Size (px)
Citation preview
Handheld Ultrasonic Flowmeter
Ⅱ-1
Features
H i g h A c c u r a c y m e a s u r i n g
Wi d e m e a s u r i n g r a n g e
L a r g e c a p a c i t y b a t t e r y
N o n - i n t r u s i v e m e a s u r i n g
S u p p o r t M u l t i p l e L a n g u a g e M e n u
L a r g e L C D d i s p l a y
B u i l t - i n d a t a l o g g e r
A c c u r a c y : ±1 % , l i n e a r i t y : 0 . 5 % , r e p e a t a b i l i t y : 0 . 2 %
S e v e r a l t y p e s t r a n s d u c e r f o r s e l e c t i o n , m e a s u r i n g p i p e s i z e f r o m D N 1 5 m m t o D N 6 0 0 0 m m
B u i l t - i n r e c h a r g e a b l e N i - M H b a t t e r y, p r o v i d e o v e r 1 2 h o u r s o f c o n t i n u o u s o p e r a t i o n
N o n - i n t r u s i v e , c l a m p - o n t r a n s d u c e r , n o p r e s s u r e d r o p , n o p i p e d i s t u r b a n c e
C h i n e s e , E n g l i s h , I t a l i a n a n d o t h e r l a n g u a g e s c a n b e c u s t o m i z e d
D i s p l a y i n s t a n t a n e o u s f l o w, a c c u m u l a t e d f l o w ( p o s i t i v e , n e g a t i v e a n d n e t ) , v e l o c i t y,
w o r k i n g s t a t u s e t c .
B u i l t - i n 2 4 K d a t a l o g g e r , s t o r e o v e r 2 0 0 0 l i n e s m e a s u r i n g d a t a
Administrator打字机文本 www.bcstgroup.com
www.bcstgroup.com
1-2Ⅱ-2
Liquid Type
This flowmeter can be virtually applied to a wide range of measurement. A variety of liquid
applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage,
reclaimed water, cooling water, river water, plant effluent. etc
Handheld Ultrasonic Flowmeter
Measuring Diagram
Clamp on Transducers
I n s t a l l t h e c l a m p o n t r a n s d u c e r ( w i t h m a g n e t ) o n t h e
p i p e , c a n f i n i s h t h e f l o w m e a s u r e m e n t . N o p r e s s u r e
d r o p , n o n e e d c u t o f f p i p e .
S e v e r a l t y p e s t r a n s d u c e r s f o r s e l e c t i o n , m e a s u r i n g
p i p e s i z e f r o m D N 1 5 m m t o D N 6 0 0 0 m m .
S e v e r a l t y p e s t r a n s d u c e r s f o r s e l e c t i o n , m e a s u r i n g
t e m p e r a t u r e r a n g e f r o m - 3 0℃ t o 1 6 0℃
B r a c k e t t r a n s d u c e r c a n s i m p l i f y t h e u l t r a s o n i c
f l o w m e t e r i n s t a l l a t i o n p r o c e s s , s h o r t e n i n s t a l l a t i o n
t i m e a n d i m p r o v e i n s t a l l a t i o n a c c u r a c y.
. I n s t a l l t h e c l a m p o n b r a c k e t t r a n s d u c e r ( w i t h
m a g n e t ) o n t h e p i p e , c a n f i n i s h t h e f l o w m e a s u r e m e n t .
N o p r e s s u r e d r o p , n o n e e d c u t o f f p i p e .
S e v e r a l t y p e s b r a c k e t t r a n s d u c e r s f o r s e l e c t i o n ,
m e a s u r i n g p i p e s i z e f r o m D N 1 5 m m t o D n 7 0 0 m m .
S e v e r a l t y p e s b r a c k e t t r a n s d u c e r s f o r s e l e c t i o n ,
m e a s u r i n g t e m p e r a t u r e r a n g e f r o m - 3 0℃ t o 1 6 0℃
Clamp on Mounting Bracket Transducers
Applications
Power Construction of Energy-saving Metallurgy Water supply and drainage PetrochemicalHeating
Administrator打字机文本www.bcstgroup.com
Handheld Ultrasonic Flowmeter
Ⅱ-3
Display
4 1 6 character screen
with backlight can display
instantaneous flow,
accumulated flow
(positive, negative and net),
velocity, working status etc
×
Transducer Interface
It is convenient for measuring data storage, if use our company's
"Flow data analysis, statistical software" for processing, can
finish the tabulation, statistical, data analysis,
printing reports, production flow curve and other functions.
Aluminum alloy Carrying Case
Parts Descriptions
Communication & Signal Output Interface
32Kbit Data Storage
Large Size
Medium Size HM-HT 568×59×110mmDN50~DN300 -30~160℃
DN300~DN700Extended EB-1 188×59×49mm-30~90℃
DN50~DN300 568×59×85mmMedium Size HM -30~90℃
DN15~DN100 318×59×85mmSmall Size HS -30~90℃
Clamp on
High TemperatureClamp on
Small Size
Medium Size
Small Size
Medium Size
Large Size
TS-2
TM-1
TL-1
TS-2-HT
TM-1-HT
TL-1-HT
DN15~DN100
DN15~DN100
DN50~DN700
DN50~DN700
DN300~DN6000
DN300~DN6000
-30~90℃ 45×25×32mm
64×39×44mm
97×54×53mm
45×25×32mm
64×39×44mm
97×54×53mm
Types Picture Spec. Model Measurement Range Temperature Dimension
MountingBracket Clamp on
High TemperatureMountingBracket Clamp on
Small Size
Extended
HS-HT
EB-1-HT 188×59×49mm
318×59×110mmDN15~DN100
DN300~DN700
-30~90℃
-30~90℃
-30~160℃
-30~160℃
-30~160℃
-30~160℃
-30~160℃
Optional Transducer
Administrator打字机文本www.bcstgroup.com
Example: -3000H1+HM++ 10m
PS: Standard confirguration = -3000H1(convertor)+TM-1+5M*2 cable +Stretcher+Couplant(1 pc)+ Carrying case+Ruler
Ⅱ-4
-3000H - - Optional Transducer Cable length
5
10
5m×2(Standard)
10m×2
Datasheet
Ordering Code
Items Performance & Parameter
Principle Transit- time ultrasonic flowmeter
Accuracy ±1%
Display 4×16 character LCD with backlight, support the language of Chinese, English and Italy
1 way OCT pulse output(Pulse width 6~1000ms,default is 200ms)
Insulate Rs232 serial interface, upgrade the flowmeter software by computer
SignalOutput
Data Interface
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed
15~6000mm
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump
Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.);Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);Chemicals (alcohol, etc.); Plant effluent; Beverage; Ultra-pure liquids, etc.
-30~160℃
No more than 10000ppm and less bubble
0~±7m/s
Convertor:-20~60℃;Flow Transducer:-30~160℃
Convertor: 85%RH;Flow Transducer: Ip67
3 AAA built-in Ni-MH batteries 1.2V(for over 12 hours of operation). 90V-260V AC adapter
1.5W
Convertor
Pipe InstallationCondition
Pipe Material
Pipe Diameter
Straight Pipe
Measuring Medium
Type of Liquid
Temperature
Turbidity
Flowrate
Working Environment
Temperature
Humidity
Power Supply
Power Consumption
Case Material ABS
Dimension 200*93*32MM(Convertor)
Handheld Ultrasonic Flowmeter
Administrator打字机文本
Administrator打字机文本JC
Administrator打字机文本JC
Administrator打字机文本JC
Administrator打字机文本
Administrator打字机文本
Administrator打字机文本
Administrator打字机文本
Administrator打字机文本
Administrator打字机文本Jiangsu Jiechuang Science And Technology Co.,Ltd Fax: 0086-517-86980638Add: 288#,Tongtai road , Jinhu Industrial Park , Huai'an ,Jiangsu ,China , Tel:0086-517-86989565
Administrator打字机文本
Ⅰ-1
JC-3000P Portable Ultrasonic Flow Meter
FeaturesHigh accuracy measuring
Wide measuring range
Large capacity battery
Built-in pinter
Data Storage
RS 485 communication
Multiple input,output signal
Accuracy: 1% , Linearity :0.5%, repeatability:0.2%
Measuring range from DN15 to DN6000mm , several types transducers for selection
Built-in rechargeable Ni-MH Battery , 12 hours of continuous operation
Immediate display printing , or print more than 20 items result by advance setting at regular time
Storage more than 20 testing results in SD card
Can send the data and test result to computer
Output signal: 4-20ma ,pulse signal , relay signal
Input Signal : 3 ways 4-20 ma
Administrator打字机文本
Administrator打字机文本
Administrator打字机文本www.bcstgroup.net
Administrator打字机文本
1
1
TS-2
TM-1
TL-1
TS-2-HT
TM-1-HT
TL-1-HT
DN15~DN100
DN15~DN100
DN50~DN700
DN50~DN700
DN300~DN6000
DN300~DN6000
DN15~DN100
DN100~DN300
DN300~DN700
-30~90℃ 45×25×32mm
64×39×44mm
97×54×53mm
45×25×32mm
64×39×44mm
97×54×53mm
318×59×85mm
568×59×85mm
HS
HM
EB-1
HS-HT
HM-HT
EB-1-HT
188×59×49mm
188×59×49mm
568×59×110mm
318×59×110mmDN15~DN100
DN100~DN300
DN300~DN700
-30~90℃
-30~90℃
-30~90℃
-30~90℃
-30~90℃
-30~160℃
-30~160℃
-30~160℃
-30~160℃
-30~160℃
-30~160℃
Ⅰ-2
JC-3000P Portable Ultrasonic Flow Meter
Measuring Diagram
Easy installation, without cutting off the fluid without pressure lose
High accuracy , easy installation Without cutting the pipe , without pressure lose
Optional Transducer
Type Picture Spec. Model Measurement Range Temperature Dimension
Clamp on
High Temp
Clamp on
Mounting
Bracket
Clamp on
High Temp
Mounting
Clamp on
Small Size
Small Size
Small Size
Small Size
Medium Size
Medium Size
Medium Size
Large Size
Large Size
Large Size
Large Size
Medium Size
Administrator打字机文本www.bcstgroup.net
CT-1 ≥DN50 -40-160℃ 100℃±0.8℃
≤0.1℃
1-3
1
1
Ⅰ-3
JC-3000P Portable Ultrasonic Flow Meter
Temperature Measurement Diaphram
Flow Pipe Return Pipe Flow Pipe Return Pipe
With clamp-on temparature sensors , portable flow meter can measure temperature and energy .
Heating and power plant
Application
Thermal electricity company Power AC refrigeration Energy-saving
Optional Temperature Sensor
Picture Type ModelMeasuring
Range Temperature
Range Installation Accuracy
Three wires PT 100 Clamp-on temperature sensor
Withoutcutting pipe
Temperature error
Wiring board
Output:4-20mApulse signal relay signal
Input Signal:3 way 4-20ma
Main Parts Introduction
SD storage card Storage data. By our data analysis software ,
it can process data , including tabulate, statistics ,
data analysis , printing ,making flow curve line .
24 characters thermal printer
It can print in time , or print 20 testing resutls
at regular time
LCD display
2*20 character screen with backlight LCD display
can display instantaneous flow
Aluminum alloy carrying case
easy carry , protective , dustproofwaterproof ,shock resistance Temperature,energy measurement
With clamp-on temperature sensor
Administrator打字机文本www.bcstgroup.net
- - -
0 ±10m/s~
1.5W
Ⅰ-4
510 5 ×2( ) 10 ×2
N1
N1 4-20mA
JC-3000P Portable Ultrasonic Flow Meter
Data Sheet
Type Performance and parameter
Main Unit
Principle Transmit-time ultrasonic flowmeter
Accuracy
Display
Signal
Output
Signal
Input
Data Interface
Data Record
PipeInstallationCondition
Pipe Material
Pipe Diameter
Straight Pipe
Measuring
Medium
Liquid
Temperature
Turbidity
Flowrate
Working
EnviromentTemperature
Humidity
Power Supply
Consumption
Better than 1%
2*20 character LCD display with backlight , language support: chinese ,English,Italy
1 Way 4-20mA current output ,resistance 0-1 k , accuracy :0.1%(optional)
1 way OCT pulse output (pulse width 6-1000ms, default is 200ms)
1 way relay output
3 way 4-20ma current input , accuracy 0.1% , collect temprature , pressure , level etc
Can connect three way PT100 resistance to measure energy
Insulate RS 485 serial interface , upgrade the flowmeter software by computer , support MODBUS
Thermal printer , outlay SD card which can reach 2 G
Steel, Stainless steel, Cast iron, Copper, Cement pipe , PVC , Aluminum ,Glass steel product , Liner is allowed
15 to 6000mm
Transducer installation should be satisfied : upstream 10D , downstream 5D , 30D from the pump
Single liquid which can transmit sound wave, such as Water , Wewage with small particle content , oil, Plant effluent , Beverage, Ultra-pure liquids ,etc
-30 to 160 °C
No more than 10000 ppm and less bubble
Main unit : - 20 to 60°C� Flow transducer : - 30 to 160°C
Main unit : 85 % RH ÿFlow Transducer : IP 67
2000mAH Bulit-in Ni-MH batteries , 8 AAA 1.2 V ( For over 20 hours operation after full charge ),
AC 90 to 260V adapter , can realize no stop measurement .
Ordering Code
JC-3000P Optional Transducer Cable length Energy Measurement Current Input
MM
Standard Without energy measuring Energy Measuring
Without Output
Jiangsu Jiechuang Science And Technology Co.,Ltd
Add: 288#,Tongtai road ,Jinhu Industrial Park, Huai'An,Jiangsu,China
Tel: 0086-517-86989565 Fax: 0086-517-86980638
[email protected] www.bcstgroup.com
Fixed Separated Ultrasonic Flowmeter
Ⅲ-1
clamp on Insertion Pipe
T h e f i x e d s e p a r a t e d m o d e l i s
i n l i n e m e a s u r e m e n t f o r l o n g - t e r m .
T h e r e a r e 3 t y p e s c o n v e r t o r s
i n c l u d i n g w a l l m o u n t e d , p a n e l
m o u n t e d a n d p r o o f - e x p l o s i o n .
C o n v e r t o r s c a n b e i n s t a l l e d a t
i n d o o r o r i n s t r u m e n t c a b i n e t
High Accuracy
Wide measuring range
High Reliability
1%
Several types transducer for selection, pipe size from Dn15mm to Dn6000mm
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
Dual-balance signal differential receiver/driver circuit to avoid interference of converter,
TV tower, high voltage line etc.
Automat ica l ly record the fo l lowing da ta :1. The totalizer data of the last 512 days/128 months/10 years2. The time and corresponding flow rate of the last 64 times of power on and off events 3. The working status of the last 32 days
iStrong Ant -interference
Power fu l Record ing Func t ion
Support Heat Measurement
eSupport SD card M mory
Connect the temperature transducer ,can finish the heat/energy measurement
Op t iona l SD card
Features
Administrator打字机文本www.bcstgroup.com
手持式超声波流量计 系列TUF-2000F手持式 声波流量计Fixed Separated Ultrasonic Flowmeter
Measuring Diagram
Supply Pipe
Supply Pipe
Return PipeInsertion
Pipe
Flow Measurement Heat Measurement Features
No need to cut off water ,no pres sur e loss
Easy for inst al lat ion
Conn ect clamp on temperat ure transducer ,
can finish the heat /energy measur ement
Liquid Type
This flowmeter can be virtually applied to a wide range of measurement. A variety of liquid
applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage,
reclaimed water, cooling water, river water, plant effluent. etc
Return Pipe
Calmp on
No need to cut off water ,no pressure loss
Stable and rel iable for long term ope rat ion
Connec t Pt100 temper ature transduc er,
can finish the heat /energ y measurement
Need to cut off pipe
With high accuracy and stability
Connect Pt100 temperature transducer,
can finish the heat/energy measurement
Optional Convertor
1
According to different installation condition, pls choose relative convertor
1Wall mounted CAM-3000SW
Wall mounting installation
Dimension :170×180×56mm
Power supply:DC8~36V orAC85~264V
Panel mounted CAM-3000SS
Instrument cabinet installation
Dimension :170×180×56mm
Hole-opening dimension:152×76mm
Power supply:DC8~36V or AC85~264V
Explosion-proof CAM-3000SD
Explosion-proof installation
Dimension :298×298×110mm
Power supply:DC8~36V or AC85~264V
Grade :DⅡBT4
Supply Pipe
Return Pipe
Ⅲ-2
Administrator打字机文本www.bcstgroup.com
Optional Temperature Transducers
Clamp on temperature Transducer Pt100 CT-1 ≥DN50 -40 160℃~
100℃±0.8℃
Picture Specification Model Meas. Range Temperature Cut of water Accuracy
No
Insertion temperature Transducer Pt100
Insertion Pt100 Installation with pressure
Yes
No
-40 160℃~
-40 160℃~
≥DN50
≥DN50
TCT-1
PCT-1
Insertion Pt100 Small size pipe diameter SCT-1 <DN50 -40 160℃~
Yes
High tempClamp on
Insertion
Clamp on
Pipe
Types Picture Spec. Model Measurement Range Temperature Dimension
Optional Transducers
Standard
Standard
Lengthen TC-2
G1
G2
DN80~DN6000
DN50~DN6000
DN32/DN40
-30~160℃
π type G3 DN15~DN25 -30~160℃
-30~160℃
-30~160℃
Large Size TL-1 DN300~DN6000 -30~90℃ 97×54×53mm
Small Size TS-2-HT DN15~DN100 -30~160℃ 45×25×32mm
Large Size TL-1-HT DN300~DN6000 -30~160℃ 97×54×53mm
Standard TC-1 DN80~DN6000 -30~160℃ 190×80×55mm
335×80×55mm
Small Size TS-2 DN15~DN100 -30~90℃ 45×25×32mm
Medium Size TM-1 DN50~DN700 -30~90℃ 64×39×44mm
Medium Size TM-1-HT DN50~DN700 -30~160℃ 64×39×44mm
Pls refer to
detailed pipe
dimensions
1-3Ⅲ-3
Fixed Separated Ultrasonic Flowmeter
Optional SD card memory
The SD card memory can be expanded to 2GB, which can achieve the ultrasonic
flowmeter measurement data mass storage, can solve the problems for wall-mounted , , flowmeter measurement data stored, reading and processing inconvenience can
, .completely replace manual meter reading no paper records instrument
In addition, the SD memory card measurements data, can be used by our
company's "Flow data analysis, statistical software" for processing, including the
tabulation, statistical, data analysis, printing reports, production flow curve and other
functions.
Raw DataCumulative F low Bar ChartGenerated by Software
SD card memory of wall mounted
Software Import DataInstantaneous Flow Curves Generated by Software
Administrator打字机文本www.bcstgroup.com
Datasheet
Items Performance & Parameter
Principle Transit- time ultrasonic flowmeter
Accuracy ±1%
Display 2×20 character LCD with backlight, support the language of Chinese, English and Italy
1 way 4~20mA output, electric resistance 0~1K,accuracy0.1%
1 way OCT pulse output(Pulse width 6~1000ms,default is 200ms)
1 way Relay output
3 way 4~20mA input, accuracy 0.1%,acquisition signal such as temperature, press and liquid level
Connect the temperature transducer Pt100, can finish the heat/energy measurement
Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS
SignalOutput
Signal Input
Data Interface
Twisted-pair cable, generally, the length under 50 meters; Select the RS485, transmission distance can over 1000m
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed
15~6000mm
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump
Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.);Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);Chemicals (alcohol, etc.); Plant effluent; Beverage; Ultra-pure liquids, etc.
-30~160℃
No more than 10000ppm and less bubble
0~±7m/s
Convertor:-20~60℃;Flow Transducer:-30~160℃
Convertor: 85%RH;Flow Transducer:can measure under water,water depth≤2m(tansducer sealed glue)
DC8~36V or AC85~264V(optional)
1.5W
Convertor
Special Cable
PipeInstallationCondition
Pipe Material
Pipe Diameter
Straight Pipe
MeasuringMedium
Type of Liquid
Temperature
Turbidity
Flowrate
WorkingEnvironment
Temperature
Humidity
Power SupplyPower Consumption
Ordering Code
Ⅲ-4
手持式超声波流量计 系列TUF-2000F手持式超声波流量计Fixed Separated Ultrasonic Flowmeter
Example: JC -3000SW+TM -1+DN300+0+1 .6MPa+ 10m+ PCT-1+
0
PS: Standard confirguration =CAM-3000SW(convertor)+TM-1+5M cable +Steel belt(DN200)+Couplant(1 pc)
JC-3000S –---- -DN - - MPa - - ----------------- - mm m
W
S
D
TS-2
TM-1
TL-1
TS-2-HT
TM-1-HT
TL-1-HT
TC-1
TC-2
G
0 Carbon Steel
1 Stainless Steel
2 Cast Iron
3 Glass Fiber reinforced
4 PVC
5 Cement
6 Others
None
CT-1
TCT-1
PCT-1
SCT-1
0 Yes
1 No
Flow
TransducerConvertorPipeMaterialDiameter Pressure
Cable
LengthSD card Memory
Temperature
Transducer
Dimension 170*180*56cm(convertor)
Administrator打字机文本Jiangsu Jiechuang Science And Technology Co.,Ltd Fax: 0086-517-86980638 Tel:0086-517-86989565
Administrator打字机文本Add: 288#,Tongtai road , Jinhu industrial Park , Huai'an , Jiangsu , China
Administrator打字机文本
Administrator打字机文本
JC-3000H-Handhold Ultrasonic Flowmeter页 1页 2页 3页 4
JC-3000P Portable Ultrasonic Flowmeter页 1页 2页 3页 4
JC-3000S Fixed Ultrasonic Flowmeter页 1页 2页 3页 4