Upload
others
View
11
Download
0
Embed Size (px)
Citation preview
Hammond, Michelle
From: Sent: To:
Hammond, Michelle Thursday, November 15. 2012 8:36 AM
Subject: Attachments:
Re: REQUEST FOR ADDITIONAL INFORMATION
image001 .png
License No.: Docket No.: Control No.:
50-02430-07 030-01179 579173
Dear Ms. Martinson:
This is in reference to your amendment request received September 25, 2012 requesting to remove a location
on Nuclear Regulatory Commission License No. 50-02430-07. In order to continue our review, we need the
following additional information:
1. Please provide a diagram of the trailer showing where each of the swipes were taken.
2. Please provide the make, model and last calibration of the LSC and/or any other survey instrumentation
you used to determine no contamination.
3. Please provide waste information regarding the muscle tissue samples that were used and analyzed for
C-14 and H-3 uptake studies, including the disposal of any residualfextra tissue not processed for liquid
scintillation counting.
We will continue our review upon receipt of this information. Please reply to my attention and refer to Mail
Control No. 579173. If you reply via email , please attach the requested documentation in PDF format or you
may fax your response to (817) 200-1188.
Please respond to my request no later than December 3. 201 2.. so that I may process this amendment.
If you have any technical questions regarding this deficiency letter, please call me at (817) 200-1127.
Best Regards,
M ichelle M. Hammond, M .5c.
Health Physicist
Region IV-Division of Nuclear Materials Safety, Branch B
office) 817-200-1127
fax) 817-200-1188
'-~US_NRC ~"':". )<""" bl~' <:~~.
~",+..J""~'
PUBLIC g. ImmedIate Rr Jc N,Jrmal Releas",
NON.PUBlIC
o A.l Senlftive.Se< 'j' I. ,",',w~ d o A.7 SeneIItw fmc:
COther~ ""--- D." {)'/I )./!;L
UNIVERSITY OF
ALASK A FAIRBANKS
Nuclear Materials Licensing Section
U.S. NucJear Regulatory Commission, Region IV
1600 E. Lamar Blvd. Arlington, TX 76011 -4511
Dear Ms. Hammond,
ENVIRONMENTAL, HEALTH, SAFETY
and RISK MANAGEMENT 1855 Marika Road
PO Box 758145
Fairbanks, Alas«a 99775-8145 (907)474-5413
(907) 474-5489 fax -w,ua1.edUlsa!etx
RECEIVED
NOV 3 0 2012
DNMS
'This letter is in response to your Request for Additional lnfonnation (Mail Control No. 579173)
regarding our request for an amendment to our Type B Broad Scope license, #50-02430-07.
docket # 030-0 1179. The request specifically outlined three items, which J address below.
1. Please provide a diagrdlll of the trailer showing where each of the swipes was laken.
A diagram of tbe trailer with each of the locations marked is attached to this document.
Severa1 of the items (Pipetman P-200, rack, centrifuge, and clip) were sitting on the
.benches. Work was done on both benches, and both were wiped with the same wipe.
2. Please provide the make, model , and last calibration of the LSC and/or any other survcy
instrumentation you used to determine no contamination.
Wipes were counted on a Beckman LS 6500. It was calibrated on June 24, 20 10 by the
Beckman-Coulter service technician, when it was installed in the trailer. The wipes wcre
counted on August 27, 2011.
The vials containing the wipes were transported to Fairbank.$ and stored in the radioactive
materials bunker behind the Arctic Health Research Building. Due to extensive
construction in the area over the past two swnmers, I have not yet incinerated any of the
wastes generated by this project. Hence, I was able to retrieve the wipe test vials and
count them on another Beckman 1.8 6500, located in room 403 of the Irving I building.
"Ibis scintillation counter had been calibrated on July 27, 2012, and 1 rccalibrated it again
on November 26, 2012. 'lbe results are shown in the following table. Opm values for
tritium and 14C were calculatcd usin~ 61.5% and 96.4% efficiency valucs, respectively.
These were measured using 3H and 4C standards and the efficiency testing parametcrs
recommended by Beckman.
Table I. Wipe test results counted on November 27, 2012 in the Irving I building at the
UAFcampus.
Location Sample N H (dpm) "Ci 'H 'c (dpm) "Ci .. c Blank nJ. 710 3.2 X 10~ 29.0 1.3 x 10->
P-200 pipetman I 198 8.9 x 10'> 26.0 1.2 x 10->
Cli~ 2 442 2.0 x 10 22.8 1.0 x 10"'
Rack 3 470 2.1 x 10 24.9 1.1 x 10"'
Centrifuge 4 309 1.4 x 10-4 18.2 8.2 x 10~
Bench tOJ>ffi 5 323 1.5 x 10 17.1 7.7 x 10-"
~r 6 567 2.5 x 10 27.0 1.2 x 10-
Waste bucket 7 393 1.8 x 10 31.1 1.4xl0-
Box (transport) 8 490 2.2 x 10 31.6 1.4 x 10-
These values are higher than the values obtained in August 20 I I, but aU of the sample
values are below the blank value, and all are below tbe limit of 0.0005 J.lCi per wipe. The
higher values could be due to changes in the light transparency of the filter media used
lor the wipe, ao:; the wipes had been in the cocktail for over 15 months.
No work has been d(me at the trailer since August, 2011. 'I"he next trip to the trailer is
planned for January 2013 (for non~radioncti ve work). If necessary. another set of wipes
can be collccted at that time. These can be counted on the Beckman LS 6500 at the
trai ler (after it is recaJibrated), and also brought to Fairbanks and counted on the
Beckman LS 6500 in room 403 of the Irving 1 building. Please advise if you wish us to
collect additional wipe samples.
3. Plcase provide waste infonnation regarding the muscle tissue samples that wcre used and
analyzed for 14C and 3H uptake studies, including the disposal of any residual/extra tissue
not processed for liquid scintillation counting.
As mentioned above, due to extcnsive construction in the West Ridge area of campus the
past two summers, I have not incinerated any radioactive wastes. The scintillation vial
wastes and the low-level solid wa<;tes (gloves, small tissue samples, and paper) are still in
storage in the radioactive materials bunker behind the Arctic Health Building. This
bllllker was inspected on November 7, 2011 by the NRC, and there is still plenty of space
for thc wastc materials that we have coll ected. Now that outdoor construction activities
have ceased, an incineration of low-level wastes is planned for December, weather
pennitting. We do not incinerate during periods or extreme cold (colder than minus-20
OF) due to temperature inversions that are not conducive to atmospheric mixing.
Sincerely,
TrarZ~~~'flMYL--Radiation Safety Officer
Attachment: 1. Diagram of trailer. showing locations of wipe tests.
~ G .' 2 "'!I:."f::' 5 1 LU
(j) 6 7 Storage
Biosafety 5 ~ r-a binet
l ocation Sample # ' H (dpm) "( (dpm) !lei lotc
" Blank ...i~ n/a """--- -. .. 16.59 II 7.5 x 10.6 14.55 6.6 x 10.6
P·200 Pipelman 1 16.91 7.6 x 10.6 12.42 5.6 x 10.6
! Clip 2 .Ji 18.79 8.5 x 10'6 " 15.56 7.0 x 10.6 .-___ c_. _ '----- - ----'""- ~ -Rack " 3 22.68 1.0 x 10·' 17.G8 8.0 x 10.6
~ - - ..... _- .. -Centrifuge j~; 4 II 17.62 .. 7.9 x 10·' 11.58 8.0 x 10.6
Bench top 5 14.99 6.8 x 10.6 14.26 6.4 x 10·'
; Floor 6 Ii 21.94 9.9 x 10.6 " 16.63 .:-0
1111 7.5 x 10" , --', ..... i-..
.... 1· ___ "" _____ ..... '-- _ I
Waste bucket 7 22.:t3 1.0 x 10-5 16.2 7.3 x 10·'
Box (transport) 8 L 15.33 -, 6.9 x 10·' 0> 13.22 6.0 x 10·'
UNIVE RSITY OF
ALASKA FAI RBAN K S
Nuclear Materials Licensing Branch
U.s. Nuclear Regulatory Commission, Region IV
1600 E. Lamar BouJevard
Arlington, TX 76011-4511
Dear Ms. Hammond:
ENVIRONMENTAL, HEALTH, SAFffi
and RISK MANAGEMENT 1855 Marika Road
PO Box 758145
Fairbanks, Alaska 99775-8145 (907) 474-5413
(907)474-5489 fax
November 29, 2012
RECEIVED
NOV 3 0 2012
DNMS
This letter is in response to your Request for Additional Information (Mail Control #579303)
regarding our request to amend our Type B Broad Scope license No. 50-02430-07, docket
number 030-01 179.
I have attached a copy of the FedEx Air Waybill and Shipper's Declaration for the shipment
containing the 50 mCi radiumJbcryllium source to Mr. William Schuck of National Security
Technologies, LLC
I have attached. a copy of the email from Mr. Schuck dated August I, 2012, which states that
they received the source on July 18, 2012. Mr. Shuck indicated they found some mdium
contamination on the threads and the interior of lid of the lead pig that contained the source (70
dpm, or 0.00003 J-lCi). J have attached the wipe test of the souree that I performed in January
2012. When r conducted the wipe test, I wiped the exterior of the lead pig, not the interior
surfaces. At the time, I thought that the item was the actual source, and that the orange cord
attached to it was for lowering it into the moisture/density gauge (sec attached photo). This
explains the discrepancy between my wipe test results and those of Mr. Schuck.
Sincerely,
(l~~!.~ Radiation Safety Officer
Attachments: I. FedExAirWaybill#80096194564
2. Shipper's Declaration for Dangerous Goods, dated July 17, 2012
3. Email correspondence from William Schuck, dated August 1. 2012
4. Stan Huber wipe test report for 50 mLI RaBe source (referred to as SHIP-II)
5_ Photograph oflead pig holding the 50 mCi Raile source.
7of7
CJ CJ ru CJ
)
' :r ,.D ,IS]
or
cr,'"" .D cr-CJ o o «l
J
!i l Q) ~ :;:;:
I
, "
R£T"'IN TH1 S ~QPV fQH yon R;:CO~OS .
• ::9
~
1. "'"' • ~
• t:-• il . a::_~ - , i !i ~ , m, - Jl .. , c:c i ~ ~
! , i- ~ ;;;'"' " .5 .£-1" ~~ . -' • ;n ~ "2
N ~
t 11129120 12 11 :46M [
SHIPPER'S DECLARAnoN FOR DANGEROUS GOODS
Martinson
UAF EH"RM 1855 Manka Road Fairbanks, AK 99709 (907) 474-6771
Schuck Bldg. 1783 Arnold Ave. Andrews AFB, MO 20762 (30 1) 221...4113
Two compIoted and signfKf copies 01 this DedlUOOon fflU$l
be h6nded to lhe opeRI'f\x.
TRANSPORT DETAILS
Fairbanks
Airport of Destination:
NATURE AND QUANTITY OF DANGEROUS GOODS
Air Waybill No.
Page 1 of Pages
Shlppet's Reference Number r_
WARNING
For optional use for
Company logo name and address
Failure 10 comply in aU respects with the applicable
Dangerous Goods Regulations may be in breach of
the applicable law, subject to legal penalties.
- - - - - -- -- - - - - --- - - -- - -- - - - 1- - - - - -- - - - - -r- - r - -- ---
~ Goods 1defl1IficeIion . • •
- -- r - - - -- - - - ------,---,---. • , UN 1 , CIim ' Pack~ , QJanlityand ,PttdU"II1 Au\tIorIzaIion
ot I Proper Shipping Nama I or 0M5i0n I Ing I typI:! of ~ I !mot. •
/0 .(Sub5iciatyr Group J
No.. ,Ri&k). , 1 J
- - - r - - - - - - - - - - - - - - -, - - - .., - - -.- - - - - - - - - - - - - - - - - - - - - -
UN2915. Radioactive matenal, Type A • 7 , , Ra-226, SO~d,O.OO1 85TBq: 11- :
I package •• • (50 mCI) • YeUow.
I I I • ,TI: O.6 .
, Dims ' 1(0)37 ' I cmx • ' (H)66 1 I an I I ,
, , , ------- ------------ --- --
Additional Handling Infonnation
1 2'''",", em.~.~'Y Ie<. no.: (907) 474-7721
Prepared in accordance with IATAJlCAO Dangerous Goods Regulations
I henoby declare that the contents of th. conaignment are fully and Namenltle at SIgnatory
accurately described above by tha Propel' shipping name, ."d are Tracey Martinson, Inclustrial Hygienist
lOizIaeif"ied, ~ltae-d. marbd and labeilltdlplacarded, and are In all
respects In proper condition for tran&port accon:tlng to appIk:abJt 17, 2012
lnt8rnadonaJ and national governmental regufatkms. I dKlare that all
of the applicabht 81r ttanspoft nrquir.menta howe been .....
l ofI
UN I VSU1T\' .,ALAS"A
FW: Neutron sources
Schuele, William H (CONTR) <[email protected].~v>
To: Trncey MarUnson <[email protected]>
Hi,
Tracey Martinson <[email protected]>
Wed, Aug 1. 2012 at 9:52 AM
I'm sorry I h3ven't gonen back to you. The source ildually arrived 7/18. I w .. s on mV way out of the office for a week off and my
counterpart was handling it.
Unfortulliltely the source ~s to be leaking. We unscrewed the top of the pig and swiped the threads and the interior part of the
pig's lid and got alxlut 70 dpm alpha.
We sent the swipes off to our lab in Nevada and it looks like it Is Radium.
00 you have any history on the shield pig? WitS that radium source a lways in mere?
Will
From: Tracey Martinson (lMilto:[email protected]]
sent: Tuesday, July 17, 2012 5:38 PM
111291201212:32 Pt
,'n,
STAN A. HUBER CONSULTANTS, INC.
200 NORTH CEDAR ROAD - NEW l..£NOX IL 60451-1751 - PHONE 815-485-4161
SEALED GAMMA/BETA SOURCES - LEAK TEST CERTIFICATE
REPORT DATE:
FACILITY:
NRC LICENSE NUMBER:
STATE LICENSE NUMBER:
SOURCE IDENTIFICATION;
ASSAY RESUlTS:
.. .... ....
1'3112012
University of Alaska Fairbanks
Fairbanks N<
50-02430-07
RADIONUCUDE;
ACTMTY: CALIBR. DATE: MANUFACTURER:
MODEL NUM BER: SERIAL NUMBER:
OTHER DESCRIPTION;
COUNTING EFFICIENCY:
226 Ra-Be Nol provided mGI Notpravided NOlprovided Nolprovided Not provided SHlP1 1
BACKGROUND AT TIME OF ASSAY:
.. '"'
.......
0.842 15 •
M~ "M "" N o ' CPM DPM " ~c ' , I , ~, ""
.,r< '40 " 0 " <"
"'" ""et 136 0 < 0.000001
ANALYSIS PEH"F0RMEO USING:
Packard Auto-Gamma SCintillation Spectrnmeter Model 105003 Serial#<t06282 and' Of
Packard 1900CA Tri-Carb Liql.!ld Scintillation Analyzer ModelfA1900 SerIal ',01464
ANAL Y51S OF RESUL T5: Sources are not leaki'lg at this time
Removable contaminatioo i& less than 5E·3 uCl. (0.005)
NEXT LEAK TEST DUE BY:
lEAK TEST PERFORMED BY'~
ANALYSIS PERFORMED BY:
January 19, 2022
Tracey Martinson
Glenn Huber ttA.e1f-
DATE: 111912012
DATE: 1/3112012
RADIATION SAFETY OFFICER SIGNATURE: ~ANN>'i1Mk: