AIRP O RT ROA D CENTRE ROAD E CARGO R OAD E C AR G O RO AD HA NG ER R O AD L A RGE PARKING LOT EXISTING BLDG. EXISTING BLD G. EXISTING BLDG. EXISTING BLDG. EXISTING BUILDING EXISTING BUILDING EXIST. BLDG. EXISTING BLDG. EXISTING BLDG. EXIST. BLDG. EXISTING BLDG. EXIST. BLDG. EXISTING BLDG. EXIST. BLDG. EXIST. BLDG. EXIST. BLDG. EXISTING BLDG. EXISTING BLDG. EXISTING BLDG. P ROP OS E D B UILDING EXIST. BLDG. ARCHITECT CHAMBERLAIN ARCHITECT SERVICES LIMITED 5096 South Service Rd. Suite 103 Burlington, ON. L7L 5H4 P: 905.631.7777 F: 905.631.7717 Contact: Stephen Blood ext 259 CIVIL STRUCTURAL MECHANICAL ELECTRICAL IBI GROUP 410 Albert Street, Suite 101 Waterloo ON N2L 3V3 Canada P +1 519 585 2255 F +1 519 585 2269 Contact: John Perks ext 1201 MTE CONSULTANTS INC. 1016 SUTTON, UNIT A BURLINGTON, ON. L7L 6B8 P: 905.639.2552 F: 905.639.7727 www.mte85.com Contact:Chris Mauro BRUMAR ENGINEERING LIMITED 2 Station Lane Markham, ON. L3R 1R3 P: 905.477.7798 F: 905.477.4086 Contact: Alberto Acosta Manuel Jordao & Associates Ltd. 556 Edward Ave., Unit 82 Richmond Hill ON. L4C 9Y5 P: (905) 780-8590 F: 905. 780. 8591 Contact: M-Reza Yousef-B. ext 225 KEY PLAN LIST OF CONSULTANTS PROJECT NO. 06/11/2014 12:39:28 PM C:\114023\114023-Air Cargo-Hamilton- 2014.04.30_htanious.rvt 06/11/2014 12:39:28 PM Hanger Service Road, Hamilton International Airport, Hamilton, ON Hamilton International Air Cargo Logistics Facility Hamilton International Air Cargo Logistics Facility 114023 LIST OF DRAWINGS A000 COVER SHEET CIVIL C-1E EXISTING CONDITIONS, REMOVALS CIVIL C-1 SITE GRADING PLAN CIVIL C-2 SITE SERVICING PLAN CIVIL ARCHITECTURAL SP-1 SITE PLAN ARCHITECTURAL SP-2 SITE PLAN DETAILS ARCHITECTURAL A002 OBC MATRIX/WALL TYPES/NOTES/LEGEND ARCHITECTURAL A003 FIRE SEPARATION PLANS ARCHITECTURAL A101 GROUND FLOOR PLAN ARCHITECTURAL A102 SECOND FLOOR PLAN ARCHITECTURAL A103 ROOF PLAN ARCHITECTURAL A201 EXTERIOR ELEVATIONS ARCHITECTURAL A301 BUILDING SECTIONS ARCHITECTURAL A302 WALL SECTIONS I ARCHITECTURAL A303 WALL SECTION II ARCHITECTURAL A304 WALL SECTION III & SECTION DETAIL ARCHITECTURAL A401 ENLARGED PLANS ARCHITECTURAL A402 REFLECTED CEILING PLANS ARCHITECTURAL A501 PLAN DETAILS ARCHITECTURAL A502 PLAN & BARRIER RAIL DETAILS ARCHITECTURAL A503 STAIR DETAILS ARCHITECTURAL A504 STAIR DETAILS ARCHITECTURAL A601 DOOR SCHEDULE ARCHITECTURAL A602 WINDOW & ROOM FINISH SCHEDULE ARCHITECTURAL A701 ENLARGED WASHROOM PLANS ARCHITECTURAL STRUCTURAL S0.0 TITLE PAGE STRUCTURAL S1.0 GENERAL NOTES STRUCTURAL S1.1 GENERAL NOTES (CONT'D) STRUCTURAL S2.0 FOUNDATION PLAN STRUCTURAL S3.0 FOUNDATION DETAILS STRUCTURAL S4.0 SECOND FLOOR FRAMING PLAN STRUCTURAL S4.1 ROOF FRAMING PLAN STRUCTURAL S5.0 FRAMING DETAILS STRUCTURAL S6.0 FRAMING ELEVATIONS STRUCTURAL S6.1 FRAMING ELEVATIONS STRUCTURAL S6.2 FRAMING ELEVATIONS STRUCTURAL S7.0 SCHEDULES STRUCTURAL MECHANICAL M-1 HVAC PLAN MECHANICAL M-2 PLUMBING PLAN MECHANICAL M-3 OFFICE AREA HVAC PLANS MECHANICAL M-4 OFFICE AREA PLUMBING PLANS MECHANICAL M-5 MECHANICAL SPECIFICATIONS MECHANICAL ELECTRICAL E-1 SITE PLAN ELECTRICAL E-1S SITE PLAN(SERVICES) ELECTRICAL E-2S SITE DETILS(SERVICES) ELECTRICAL E- 2 WAREHOUSE PLAN LIGHTING LAYOUT AND DETAILS ELECTRICAL E- 3 WAREHOUSE PLAN POWER LAYOUT AND DETAILS ELECTRICAL E- 4 CARGOJET MEZZANINE LIGHTING&POWER ELECTRICAL E- 5 GENERAL CARGO PART PLANS LIGHTING&POWER ELECTRICAL E- 6 GENERAL CARGO DISTRIBUTION AND DETAILS ELECTRICAL E- 7 GENERAL CARGO SPECIFICATIONS ELECTRICAL ISSUED FOR DATE FOR CONSTRUCTION NOVEMBER 05,2014 IFC NOC A-2

Hamilton International Air Cargo NOC Logistics Facility ORT ROAD C E N T R E

Embed Size (px)

Citation preview

AIRPORT ROAD

CE

NTR

E R

OAD

E C

AR

GO R

OAD

E CARGO ROAD

HANGER ROAD

LA

RGE

PA

RKIN

G L

OT

EXISTING BLDG.

EXIS

TIN

G B

LDG

.

EXISTING BLDG.

EXISTING BLDG.

EXISTINGBUILDING

EXISTINGBUILDING

EXIST. BLDG.

EXISTING BLDG.

EXISTING BLDG.

EXIST.BLDG.

EXIS

TIN

G B

LDG

.

EXIST.BLDG.

EXIS

TIN

G B

LD

G.

EXIST.BLDG.

EXIST.BLDG.

EXIST.BLDG.

EXISTING BLDG.

EXISTING BLDG.

EXISTING BLDG.

PROPOSED BUILDING

EXIST. BLDG.

ARCHITECT

CHAMBERLAIN ARCHITECT SERVICES LIMITED5096 South Service Rd. Suite 103Burlington, ON. L7L 5H4P: 905.631.7777F: 905.631.7717Contact: Stephen Blood ext 259

CIVIL

STRUCTURAL

MECHANICAL

ELECTRICAL

IBI GROUP410 Albert Street, Suite 101Waterloo ON N2L 3V3 CanadaP +1 519 585 2255F +1 519 585 2269Contact: John Perks ext 1201

MTE CONSULTANTS INC.1016 SUTTON, UNIT ABURLINGTON, ON. L7L 6B8P: 905.639.2552F: 905.639.7727www.mte85.comContact:Chris Mauro

BRUMAR ENGINEERING LIMITED2 Station LaneMarkham, ON. L3R 1R3P: 905.477.7798F: 905.477.4086Contact: Alberto Acosta

Manuel Jordao & Associates Ltd.556 Edward Ave., Unit 82Richmond Hill ON. L4C 9Y5P: (905) 780-8590F: 905. 780. 8591Contact: M-Reza Yousef-B. ext 225

KEY PLAN

LIST OF CONSULTANTS

PROJECT NO.

06/1

1/2

014 1

2:3

9:2

8 P

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

06/1

1/2

014 1

2:3

9:2

8 P

M

Hanger Service Road,Hamilton InternationalAirport, Hamilton, ON

Hamilton International Air CargoLogistics Facility

Ham

ilton Inte

rnational Air C

arg

oLogis

tics F

acility

114023

LIST OF DRAWINGS

A000 COVER SHEET

CIVIL

C-1E EXISTING CONDITIONS, REMOVALS CIVIL

C-1 SITE GRADING PLAN CIVIL

C-2 SITE SERVICING PLAN CIVIL

ARCHITECTURAL

SP-1 SITE PLAN ARCHITECTURAL

SP-2 SITE PLAN DETAILS ARCHITECTURAL

A002 OBC MATRIX/WALL TYPES/NOTES/LEGEND ARCHITECTURAL

A003 FIRE SEPARATION PLANS ARCHITECTURAL

A101 GROUND FLOOR PLAN ARCHITECTURAL

A102 SECOND FLOOR PLAN ARCHITECTURAL

A103 ROOF PLAN ARCHITECTURAL

A201 EXTERIOR ELEVATIONS ARCHITECTURAL

A301 BUILDING SECTIONS ARCHITECTURAL

A302 WALL SECTIONS I ARCHITECTURAL

A303 WALL SECTION II ARCHITECTURAL

A304 WALL SECTION III & SECTION DETAIL ARCHITECTURAL

A401 ENLARGED PLANS ARCHITECTURAL

A402 REFLECTED CEILING PLANS ARCHITECTURAL

A501 PLAN DETAILS ARCHITECTURAL

A502 PLAN & BARRIER RAIL DETAILS ARCHITECTURAL

A503 STAIR DETAILS ARCHITECTURAL

A504 STAIR DETAILS ARCHITECTURAL

A601 DOOR SCHEDULE ARCHITECTURAL

A602 WINDOW & ROOM FINISH SCHEDULE ARCHITECTURAL

A701 ENLARGED WASHROOM PLANS ARCHITECTURAL

STRUCTURAL

S0.0 TITLE PAGE STRUCTURAL

S1.0 GENERAL NOTES STRUCTURAL

S1.1 GENERAL NOTES (CONT'D) STRUCTURAL

S2.0 FOUNDATION PLAN STRUCTURAL

S3.0 FOUNDATION DETAILS STRUCTURAL

S4.0 SECOND FLOOR FRAMING PLAN STRUCTURAL

S4.1 ROOF FRAMING PLAN STRUCTURAL

S5.0 FRAMING DETAILS STRUCTURAL

S6.0 FRAMING ELEVATIONS STRUCTURAL

S6.1 FRAMING ELEVATIONS STRUCTURAL

S6.2 FRAMING ELEVATIONS STRUCTURAL

S7.0 SCHEDULES STRUCTURAL

MECHANICAL

M-1 HVAC PLAN MECHANICAL

M-2 PLUMBING PLAN MECHANICAL

M-3 OFFICE AREA HVAC PLANS MECHANICAL

M-4 OFFICE AREA PLUMBING PLANS MECHANICAL

M-5 MECHANICAL SPECIFICATIONS MECHANICAL

ELECTRICAL

E-1 SITE PLAN ELECTRICAL

E-1S SITE PLAN(SERVICES) ELECTRICAL

E-2S SITE DETILS(SERVICES) ELECTRICAL

E- 2 WAREHOUSE PLAN LIGHTING LAYOUT AND DETAILS ELECTRICAL

E- 3 WAREHOUSE PLAN POWER LAYOUT AND DETAILS ELECTRICAL

E- 4 CARGOJET MEZZANINE LIGHTING&POWER ELECTRICAL

E- 5 GENERAL CARGO PART PLANS LIGHTING&POWER ELECTRICAL

E- 6 GENERAL CARGO DISTRIBUTION AND DETAILS ELECTRICAL

E- 7 GENERAL CARGO SPECIFICATIONS ELECTRICAL

ISSU

ED

FO

RD

ATE

FO

R C

ON

STR

UC

TIO

NN

OVEM

BER

05,2

014

IFC

NOCA-2

ABBREVIATIONS

CJ CARGOJETGC GENERAL CARGOGF GROUND FLOORSF SECOND FLOORMEZZ. MEZZANINE FLOORW.R. WASHROOMACT ACCOUSTICAL CEILING TILEC.B. CONCRETE BLOCKCMU CONCRETE MASONRY UNITCT CERAMIC TILECU CONDENSING UNITC/W COMPLETE WITHD DRYEREF EXHAUST FANEIFS EXTERIOR INSULATION FINISH SYSTEMF FREEZERF/A FIRE ALARMFHC FIRE HOSE CABINETFEC FIRE EXTINGUISHER CABINETFRP FIBERGLASS REINFORCED PANELG.B.,GYP. BD. GYPSUM BOARDHP HEAT PUMPHB HOSE BIBK.E.S. KITCHEN EQUIPMENT SUPPLIERMO MASONRY OPENINGM.U.A. MAKE-UP AIR

HM HOLLOW METALSCW SOLID CORE WOODO.C , O/C ON CENTERP PANELPTAC PACKAGED TERMINAL AIR CONDITIONERPTD PAINTEDQT QUARRY TILER REFRIGERATORRB RUBBERS SINKSACT SUSPENDED ACCOUSTICAL TILESP SUMP PUMPST STORAGE TANKT TRANSFORMERTXT TEXTUREDU.N.O. UNLESS NOTED OTHERWISEVEND. VENDING MACHINEW WASHERVCT VINYL COMPOSITE TILEVWC VINYL WALL COVERING

ONTARIO 2012 BUILDING CODE DATA MATRIXItem

1 PROJECT NAME & LOCATION

HAMILTON INTERNATIONAL AIR CARGO LOGISTICS FACILITY

New

Addition

Alteration

Change of Use

2 MAJOR OCCUPANCY (S) MEDIUM HAZARD INDUSTRIAL OCCUPANCIES: F-2

3 BUILDING AREA New: 6163 m2

4 GROSS AREA New: 6957.5 m2

5 NUMBER OF STOREYS Above Grade: 2 Storeys Below Grade: N/A

6 HEIGHT OF BUILDING 31'-2" (9.5m) (Top of Roof Slab)

7 NUMBER OF STREETS/ACCESS ROUTES Facing 1 Street

8 BUILDING CLASSIFICATION

9 SPRINGKLER SYSTEM PROPOSED

GROUP F DIVISION 2, ANY HEIGHT, ANY AREA, SPRINKLERED

entire building

basement only

in lieu of roof rating

not required

10 STANDPIPE REQUIRED YES NO

NO

NO

NO

YES

YES

YES

11 FIRE ALARM REQUIRED

12 WATER SERVICE/SUPPLY IS ADEQUATE

13 HIGH BUILDING

14 CONSTRUCTION PERMITTED Combustible

Combustible

Non-combustible

Non-combustible

Both

Both

15 SECOND FLOOR(S) AREA

16 OCCUPANT LOAD BASED ON m2/person design of building

Tenant #1(Cargojet) Warehouse Occupancy: F2 Load: 75 persons

17 BARRIER FREE DESIGN YES

YES

NO

NO

(explain)_________________

18 HAZARDOUS SUBSTANCES

19 Required

Fire

Resistance

Rating

(FRR)

Horizontal AssembliesFRR (Hour)

Listed Design No.or Description (D-2)

floors 2 hours hours

roof no rating hours

second 2 hours

FRR ofSupporting Members

floors 2 hours hours

roof no rating hours

second 2 hours

Listed Design No.or Description (D-2)

20 WASHROOM FACILITIES W.C.s REQUIRED(male/fem.)

Ground Floor Tenant#1 : Occupancy: F2 2/3 Male &1/3Female =75/24

W.C.s PROVIDED(male/fem.) UNISEX

21 EXITS REQUIRED(from level) No. Exit Width Max Travel

(mm per exit) (m to one exit)

1st Floor: 2 915 45

2nd Floor (Tenant#1) 2 915 45

2nd Floor (Tenant#2) 1 915 25

22 SPATIAL SEPARATION - Construction of Exterior Walls

Wall

North

South

East

West

AreaEBF(m2)

L.D.

(m)

L/HorH/L

PermittedMax % ofOpenings

Proposed% ofOpenings

FRR(hours)

PROVIDED No. Exit Width

(mm per exit)

ListedDesign orDescription

Comb.Const.

Comb.Const.Non-comb.Cladding

Non-comb.Const.

Part 3 Part 9 Part 11

OBC Reference

3.1.2.1.(1)

1.4.1.2.

1.4.1.2.

1.4.1.2. & 3.2.1.1.

3.2.2.10

3.2.2.67

3.2.2.67 / 3.2.2.68.B

3.2.9.1.(1)

3.2.4.1.(2)

3.2.5.7

3.2.6.1

3.2.2.67

3.2.1.1

3.1.17.1.

3.8.

3.3.1.2.(1)&3.3.1.20

3.7.4.9(1)

3.4.2.1 number3.4.2.5(1)(c) location3.4.3.2(8)(c) width3.4.3.2.(1)(a) capacity

grd. level3.4.3.2.(1)(c) capacity

upper levels

3.2.3.1

TOTAL 167 persons

4/2 1

15 915

2 915

1 915

* 5.0 m

80.30 m

56.97 m

6.00 m

1210 m2

79.87 m2

307.76m2

27.61 m2

Table D-2.2.1.A.

Table D-2.2.1.

CONSTRUCTION ACTUAL

NEW (Tenant#1and Tenant2)area= 526+268.5=794.5 m2 >10%

Warehouse: Occupancy: F2 Load: 167 persons

Ground Floor:

Tenant #1(Cargojet) Office Occupancy: D Load: 24 persons

Second Floor:

Tenant #2(GeneralCargo) Warehouse &OFFICE Occupancy: F2&D Load: 33 persons

Tenant #1(Cargojet) Office Occupancy: D Load: 21 persons

3.2.2.67 / 3.2.2.68.B

3.2.2.67

Second Floor Tenant#1 : Occupancy: D

Ground Floor Tenant#2 : Occupancy: F2 2/3 Male &1/3Female=22/9

3.7.4.7(1)

3.7.4.9(1)

100%

100%

100%

100%

13.5 m497.85 m2 80%

83.29 m298.65 m2

100%

28.77 m865.75 m2 100%100%60.24 m262.06m2

GROUP D , ANY HEIGHT, ANY AREA 3.2.2.44

3.2.2.44

* CONCRETE APRON AT NORTHSIDE CONSIDERED EQUIVALENT TO STREET

0

0

0

1

0

00

0

Tenant #2(General Cargojet) Office Occupancy: D Load: 14 persons

Second Floor Tenant#2 : Occupancy: D 1/1 3.7.4.7(1)

10

By Tenant

2/2

2/2

2/2

3.4.2.1.B

AXXX

XSIM

101

A101

1Ref

1

Ref

1

Ref

1Ref

X

XXX

XXX

NameElevation

1

A101

1

A101

SIM

WT1GRID NUMBER

ROOM NAME

ROOM NUMBER

ROOM SQUAREFOOTAGE

WALL TYPE

ROOF TYPE

DOOR NUMBER

WINDOW NUMBER

INTERIOR FINISHNUMBER

NOTE TAG

EQUIPMENT NUMBER

CEILING MATERIAL

CEILING HEIGHT

X-000 FURNISHINGS REFERENCE

DATUM ELEVATION

CEILING REFERENCE

DETAIL REFERENCE

DETAIL NO.

SHEET NO.

INTERIOR ELEVATION REFERENCE

ELEV. NO.

SHEET NO.

xxx AFFSPOT ELEVATION

WALL SECTION REFERENCE

BUILDING SECTION REFERENCE

WASHROOM ACCESSORIES TAG

SYMBOL LEGEND

NEW/EXTERIOR ELEVATION KEYNOTE

PARKING TAG1i

200

100

01

300

DEMOLITION TAG

MILLWORK TAG

EXTERIOR WALL AT LOADING DOCKS

- 250 mm ARCHITECTURAL INSULATED PRECASTCONCRETE WALL PANEL - (RSI 1.76)(TO 4570.0 mm AFF)

EXTERIOR WALL AT WAREHOUSE, OFFICE

- 100 mm INSULATED METAL PANEL - (RSI 4.83)

WALL TYPES

GRID

460

250

GRID

300

100

WT 1

WT1 WT2

WT 2

WT3

WT3

2HR. FIRE RATED METAL STUD PARTITIONAS PER ULC W 453 WALL DESIGN

- 16 mm GYPSUM BOARD- 16 mm GYPSUM BOARD- 92 METAL STUD @ 400 O/C- 16 mm GYPSUM BOARD- 16 mm GYPSUM BOARD

WT 5

WT5

16 16

92

1616

156

1HR. FIRE RATED METAL STUD PARTITIONAS PER ULC W 407 WALL DESIGN

- 16 mm FIRE RATED GYPSUM BOARD- 203 METAL STUD @ 300 O/C- BATT INSULATION (RSI 4.40)- 6 mm POLY VAPOUR RETARDER BARRIER- 16 mm FIRE RATED GYPSUM BOARD

NOTE: APPLY VAPOUR RETARDER BARRIER AT CARGOJET SIDE

ROOF TYPE:

WT4

WT4

1HR. FIRE RATED METAL STUD PARTITIONAS PER ULC W 407 WALL DESIGN

- 16 mm FIRE RATED GYPSUM BOARD- 152 METAL STUD @ 400 O/C- 16 mm FIRE RATED GYPSUM BOARD

NOTE: GYPSUM BOARD TO EXTEND A MIN. OF 203mmABOVE CEILING ELEVATION WITH STEEL STUDS TOEXTEND TO U/S OF DECK OR TO U/S OF O.W.S.J.SEAL WITH FIRE-STOPPING MATERIAL.

WT3a

WT3a

2HR. FIRE RATED METAL STUD PARTITIONAS PER ULC W 407 WALL DESIGN

- 16 mm FIRE RATED GYPSUM BOARD TO EXTEND 3000MM ABOVE F.F.- 16 mm FIRE RATED GYPSUM BOARD- 203 METAL STUD @ 300 O/C- BATT INSULATION (RSI 4.40)- 6 mm POLY VAPOUR RETARDER BARRIER- 16 mm FIRE RATED GYPSUM BOARD- 16 mm FIRE RATED GYPSUM BOARD EXTEND 3000MM ABOVE F.F.

NOTE: APPLY VAPOUR RETARDER BARRIER AT CARGOJET SIDE

WT4a

SAME AS WT4 BUT 152 LOAD-BEARING STEEL STUDS INPLACE OF 152 METAL STUD WT 5a

SAME AS WT5 BUT 92 LOAD-BEARING STEEL STUDS INPLACE OF 92 METAL STUD

WT6

WT6

- 16 mm GYPSUM BOARD- 152 METAL STUD @ 400 O/C- BATT INSULATION- 16 mm GYPSUM BOARD

WT 6a

SAME AS WT6 BUT 152 LOAD-BEARING STEEL STUDS INPLACE OF 152 METAL STUD

WT7

WT7

- 16 mm GYPSUM BOARD- 152 METAL STUD @ 400 O/C- 16 mm GYPSUM BOARD

GYPSUM BOARD TO EXTEND A MIN. OF 200 mm ABOVE CEILINGELEVATION WITH STEEL STUDS TO EXTEND TO U/S OF DECK OR TOU/S OF O.W.S.J.

WT8

FURRING WALL

- 16 mm GYPSUM BOARD- 92 METAL STUD @ 400 O/C

WT9

2HR. SHAFT WALLFIRE RATED METAL STUD PARTITIONAS PER ULS W 452 WALL DESIGN

- 25.4 mm FIRE RATED GYPSUM BOARD- 63 C-H STEEL STUDS @ 610 O/C- 13 mm FIRE RATED GYPSUM BOARD- 16 mm FIRE RATED GYPSUM BOARD

NOTE: ADD 3RD. LAYER OF DRYWALL 16mm BELOWWHEN USED HORIZONTALLY BELOW STAIR

WT8 WT9

WT7a

SAME AS WT7 BUT 92 STEEL STUDS IN PLACE OF152 STEEL STUD

- 6 mm 2-PLY MODIFIEND BITUMINOUS ROOFING SYSTEM ON METAL DECK WHITE ROOF- 6 mm RECOVERY BOARD OVERLAY- 125 mm RIGID POLYISOCYANURATE SLOPED ISNULATION BOARD AS NOTED ON DRAWINGS FOR CRICKETS AROUND EQUIPMENT ANDAREAS WHERE SLOPE TO DRAIN IS NOT PROVIDED BY STEEL DECK - RSI4.40 (R25) AT ROOF DRAIN- 6 mm POLY VAPOUR RETARDER BARRIER- 16 mm DENS DECK PRIME DECK OVERLAY- 40 mm METAL DECK

RT1

RT1

16

152

16

184

16

92

108

25

63

13

16

117

16

203

16

235

16

152

16

184

16

16

203

16

16

266

16

152

16

184

6

6

125

16

40

193

WT8a

- 16 mm FIRE RATED GYPSUM BOARD- 16 mm FIRE RATED GYPSUM BOARD- BATT INSULATION (RSI 4.40)- 6 mm POLY VAPOUR RETARDER BARRIER- 92 METAL STUD @ 400 O/C

16

16

92

108

WT8a

WT8b

- 16 mm FIRE RATED GYPSUM BOARD- 16 mm FIRE RATED GYPSUM BOARD- 92 METAL STUD @ 400 O/C

WT8c

- 16 mm FIRE RATED GYPSUM BOARD- 16 mm FIRE RATED GYPSUM BOARD- 64 METAL STUD @ 400 O/C

WT8d

SAME AS WT8a BUT 64 LOAD-BEARING STEEL STUDS INPLACE OF 92 METAL STUD

WT 6b

SAME AS WT6 BUT 16mm FIRE RATED GYPSUMBOARD IN PLACEOF 16mm GYPSUMBOARD AS PER ULC W453

9

WT4b

SAME AS WT4 BUT 92mm IN PLACE OF 152mm STEELSTUDS AS PER ULC W407

9

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

7:1

0 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A002

OBCMATRIX/WALL

TYPES/NOTES/LEGEND

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

Area Schedule

Name Area Level

CARGOJET WAREHOUSE 2820 m² T/O GROUND FLOOR

GENERAL CARGO WAREHOUSE 2955 m² T/O GROUND FLOOR

MECHANICAL AND ELECTRICAL SPACES 34 m² T/O GROUND FLOOR

CARGOJET DOCUMENTATION 94 m² T/O GROUND FLOOR

GENERAL CARGO OFFICE 259 m² T/O GROUND FLOOR

CARGOJET OFFICE AT SECOND FLOOR 525 m² SECOND FLOOR

GENERAL CARGO OFFICE AT SECOND FLOOR 268 m² SECOND FLOOR

NO. ISSUED DATE

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

UPUP

UPUP

FIRE SEPARATION LEGEND

1 HR FIRE RESISTANCE RATING

MAX. TRAVEL DISTANCELENGTH = 45M (147'-6")

2 HR - EXIT STAIRS1 HR - SERVICE & ELECTRICAL ROOMS2 HR - FLOORS2 HR - COLUMNS & BEAMS SUPPORTING FLOOR ASSEMBLY0 HR - ROOF

2 HR FIRE RESISTANCE RATING

ALL 2HR. FIRE RATED PARTITIONS TO HAVE 2 HR. FIRE STOP ASSEMBLE AT THE TOP WHEN MEETSFLOOR/ROOF METAL DECK. ABOVE

PROVIDE 2HR. ULC FIRE RATED COATING INSTALLED & MANUFACTURED REQUIRMENTSTO SECOND FLOOR AND FUTURE MEZZANINE FLOOR.(BY 3M FIRE DAM INTUMESCENT COATING WB 1000 OR APPROVED EQUAL)

A A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

14

14

15

15

B B

C C

D D

E E

F F

G G

A1

B1

C1

D1

E1

F1

16

16

13

13

EXIT EXIT EXIT EXITEXITEXIT

EXIT

EXIT EXIT

EXIT

EXITEXIT

EXIT

EXIT

17.00m < 40M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(b)

14630

34892

5124

2585

3629

5763 2137 7740 65364

19812 538078664407 44651 8069 30614

13446 21862 3230 115728500

14642

1560

16158

8.50m < 40M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(b)

32.75m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(C)

EXIT

41.00m < 45M TRAVELDISTANCE TO EXIT(OBC 3.4.2.5(C)

MAINTAINING MIN.3'-8"(1100mm)CLEAR TYP.

8" FIRE RATED GYP.BOARD WALLPROVIDING 2hr F.R.R.

40.50m < 45M TRAVELDISTANCE TO EXIT(OBC 3.4.2.5(C)

37.00m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(C)

34.00m < 45M TRAVELDISTANCE TO EXIT(OBC 3.4.2.5(C)

EXIT

32.25m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(C)

38.00m < 45M TRAVELDISTANCE TO EXIT(OBC 3.4.2.5(C)

21.50m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(C)

27.50m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(C)

STEEL FRAMING SUPPORTING SECOND FLOOR TOHAVE 2HR. ULC FIRE RATED COATING INSTALLED& MANUFACTURED REQUIRMENTS

STEEL FRAMING SUPPORTING MEZZANINEFLOOR TO HAVE 2HR. ULC FIRE RATEDCOATING INSTALLED & MANUFACTUREDREQUIRMENTS

EXIT

EXIT

EXIT

NOCA-1

NOCA-1

A A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

14

14

15

15

B B

C C

D D

E E

F F

G G

A1

B1

C1

D1

E1

F1

16

16

13

13

31.00m < 45M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(b)

31.10m < 40M TRAVEL DISTANCETO EXIT (OBC 3.4.2.5(b)

25.00m = 25.00m TRAVELDISTANCE TO EXIT (OBC 3.4.2.2)

14.00m = 25.00m TRAVELDISTANCE TO EXIT (OBC 3.4.2.2)

9

STEEL COLUMN / BEAM

2 HR. FIRE RESISTANCERATING REQUIRED

*THIN-FILM INTUMESCENTCOATING

*STEEL FRAMING SUPPORTING SECOND FLOOR TO HAVE 2HR. ULCFIRE RATED COATING INSTALLED & MANUFACTURED REQUIRMENTS

*ADJUST COATING THICKNESS PERINDIVIDUAL COLUMN/BEAM SIZE

ULC Design NO. Z610

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

7:1

3 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A003

FIRESEPARATION

PLANS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 300A003

1 GROUND FLOOR FIRE SEPARATION PLAN

1 : 300A003

2 SECOND FLOOR FIRE SEPARATION PLAN 1 : 10A003

3 FIRE RATED COLUMN / BEAM-2HR.

NO. ISSUED DATE

FOR CLIENT REVIEW AUGUST 01,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

UP

UP

UP

FD

FD

FD

FD

FD

FD

FD

A A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

14

14

15

15

B B

C C

D D

E E

F F

G G

8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 5750 9125 9125 8000

2

A301

GENERAL CARGOWAREHOUSE

105

CARGOJET DOCUM.

101

VAULT

113

1

A301

A1

B1

C1

D1

E1

F1 3

A302

16

16

13

13

PROPOSED LOCATION OFCARGOJET MAIN SERVICE PANEL.SEE ELECTRICAL DWGS.PROVIDE LIFT OUT GUARD RAILSAS REQUIRED TO PROVIDEACCESS TO ELECTRICAL PANELSFOR MAINTENANCE

PROPOSED LOCATION OFCARGOJET OFFICEPANELS &TRANSFORMER.SEE ELECTRICAL DWGS.

PROPOSED LOCATION OF GENERALCARGO OFFICE PANELS TRANSFORMER

PROPOSED LOCATIONOF GENERAL CARGO MAINSERVICE

MAINTAIN 1100mm WIDTHPEDESTRIAN WALKWAY(PAINT YELLOW COLOR ONFLOOR)

-1.22 m

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

18'-0" W X 16'-0" HRAPID-ROLL TYPE

DRIVE THROUGH DOOR

14'-0" W x 12'-0" HRAPID-ROLL TYPE

DRIVE THROUGH DOOR

8'-0" W X 10'-0" HO/H DOCK DOORVERTICAL LIFT WITH9' WIDE X 13'-2" LENGTH PITW/SCISSOR LIFT BY TENANT

12'-0" W X 14'-0" HDRIVE THROUGH DOOR

VERTICAL LIFT

18'-0" W X 16'-0" HRAPID-ROLL TYPE

DRIVE THROUGH DOOR

WT 1

100h

WT2

WT2

WT2

WT2

WT2

WT2

WT2

CARGOJETWAREHOUSE

100

STAIR NO.1

102

GC DOCUM.@GF

109

106 m²

GC OFFICE @GF

108COOLER

106

VESTIBULE

112

100g 100f 100e 100d 100c 100b 100a 112b 112a 105j 105h 105g 105f 105e 105d105b

105a

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

14'-0" W X 12'-0" HRAPID-ROLL TYPE

DRIVE THROUGH DOOR

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

100p 100q100t 105k

105m 105n 105p 105r

106d

112c 112e

100m

102b118b

118a

113

106a

101a

112f

109b

112d

117c

105s

105c

100j

109c

108b

109a

108a

119b

111

110

GC WOMEN'SW.R.@GE

110

GC MEN'S W.R.@GF

111

FIRE SUPPRESSION

115

WT4a

101b

WT4

100n

14'-0" W X 12'-0" HRAPID-ROLL TYPE

DRIVE THROUGH DOOR

2

A302

3

A301

A401

4

A701

1

A401

2

CONFIRM W/TENANT

4750

OUTLINE OF STATICSTORAGE RACKSBY TENANT

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

100r

CONFIRM W/TENANT

4620

8700

5028

2100

116a

115

ELECTRICAL ROOM

116

CJ WOMEN'SW.R.@GF

103

CJ MEN'S W.R @GF

104

CONFIRM W/TENANT

4471

2" Conduit for Load cell wires4" below floor

Scale DeckBY TENANT

Scale Deck12'x12'

BY TENANT

117a

OUTLINE OF DOCKLEVELER PIT (10 TYP.)

116b

A503

5

103

104

COOLER&FREEZER PANELS,EQUIPMENTS AND DOORS BYCOOLER / FREEZERSUPPLIER

105q

EXIT CORRIDOR

117

A401

5

CONFIRM W/TENANT

4620

117b

STAIR NO.2

118

A501

1

A501

2

A501

3

A501

4

A501

6

A501

13

A501

8

A501

7

A501

10A501

11

A501

12

9'-0" W X 10'-0" HO/H DOCK DOORVERTICAL LIFTWITH 6' WIDEX8'LENGTH PITW/HYDRAULICDOCK LEVELER(PIT SIZE TO BECONFIRMED W/DOCK EQUIPMENTSUPPLIER

OUTLINE OFCONTAINERHANDLINGSYSTEM BYTENANT

OUTLINE OF STATICSTORAGE RACKSBY TENANT

OUTLINE OFSECOND FLOORABOVE

CW1

CW1

CW2

W1

W1

W1

W1

LINE OF RETAINING WALLW/GUARDRAIL.REFER TOSITE PLAN FOR LENGTH

LINE OF RETAINING WALLW/GUARDRAIL.REFER TOSITE PLAN FOR LENGTH

0.00 m

OUTSIDE FACE OF WALL TO OUTSIDE FACE OF WALL

120800

60860

WT3

WT3

WT3

WT4a

WT4a

WT4

WT5a

WT5a

WT3a

WT4a

WT4a

WT7

WT6

106e

100k

100s

102a

4

22 2

2

2

2

2

WT5

TRANSFORMERSEE ELECTRICALDWGS.

LINE OF TRENCH DRAINREFER TO CIVILDWGS.FOR LOCATIONAND SPEC.

RECESSEDFIRE ALARMANNUNCIATORBOX

5 5

55

5

55

OUTLINE OFSCISSOR LIFTPIT(6 TYP.)PIT SIZECONFIRMW/TENANT

A501

5

A501

9

GENERATORSEE ELECTRICALDWGS.

1

1

1

111

1

11

11

1

1

1 1

1

1

1

1 1 1 1 1

1

1

1

STAIR NO.3

119119a

A504

1

DOOR

DOOR DOOR

GC MANAGER OFFICE@GR

120

DOOR(TYP.)

2000DOOR

(TYP.)

2000

FUTURE BUILD UP /BREAK DOWNWORK STATIONS BYOWNER

OUTLINE OF FLUSHMOUNTED WEIGH SCALE(3000x3000mm)BY TENANT

OUTLINE OF FLUSH MOUNTEDWEIGH SCALE (3000x3000mm)BY TENANT

OUTLINE OFCOUNTER SCALE(1500x1500 mm)

WT2

OUTLINE OF TRUCKDOCK ULD BY-BASS

OUTLINE OF ELECTRICALHOIST ABOVE.10.000 lb CAPACITY POINTLOAD ON STRUCTUREROOF

OUTLINE OFWEIGH SCALE(1500x1500 mm)

OUTLINE OF D.GOODSSTORAGE RACKS BYTENANT

OUTLINE OF X-RAY)BY TENANT

END O/HEAVY-DUTY BARRIERRAIL

1

d

2

2

2" Conduit for Load cell wires4" below floor

3

0.00 m

14'-0" W X 12'-0" HDRIVE THROUGH DOOR

VERTICAL LIFT

RWLRWL

RWL

RWL

RWL

RWL

RWL

2

2

2

2

2

2

2

Pit Size 4.50m x 3.00m(depth to be confirmed)

2

1160

3

7

7

7

7

SK-10a

1

3222

3 3

3

2

3

120

3

3 3

121CARGOJETVESTIBULE

121

SCALE

PIT SIZE TO BE COFIRMEDW/ TENANTPIT TO BE CENTREDW/DOOR CENTRELINE

3

3

PIT SIZE TO BECOFIRMED W/ TENANTPIT TO BE CENTREDW/DOOR CENTRELINE

3

3

3 3

TYP.

44

44 44

44

44

444

44 4 44 44 44 44

5

3

7

CCO#1

2

* ADDITIONALMODIFICATION BYTENANT TOADDENDUM #A03

A501

15

A701

2

CJ UNIVERSALW.R.@GF

122

10

122

1

A304

6 6

6

6

IFC

NOCA-1

2 HR FRR SHAFT WALLU/S OF STAIR TO BEEXTENDED TO THEINTERIOR SIDE OF IMP

66

FREEZER

107

NUMBER, SIZE ANDLOCATION OF PITS TOBE DETERMINED

d

A501

16

NOCA-2

NOCA-3

NOCA-3

460

13736

18448

12857

4475

10484

1

400 2743 45139 2106 36061 17858

1563 1580 6236

GUARD RAILU/S OF STAIR

1 36301 18250 8000 400

400

15000

10684

34316

4148

45934

1

3' - 3 15/16"

1- HEAVY-DUTY BARRIER RAIL

2- HEAVY-DUTY COLUMN PROTECTOR. COORDINATE W/TENANT EQUIPMENT LAYOUT

3- CONCRETE FILLED METAL BOLLARD

4- CONCRETE FILLED METAL BOLLARD LOCATED AT BOTH SIDES OF BOTH JAMBS FOR ALLDRIVE THOUGH DOORS, COOLER AND FREEZER DOORS, 300mm FROM DOOR STRUCTURE.

5- FLOOR DRAIN SLOPE BAY 1% TO DRAIN. COORDINATE W/TENANT EQUIPMENT LAYOUT

6- LOCATION OF WALL MOUNTED AUTOMATIC BARRIER FREE DOOR OPENER PUSH BUTTON

7- PROPOSED LOCATION OF CHARGING STATION. SEE ELECTRICAL DRAWINGS.

- HEAVY-DUTY BARRIER RAIL TO BE FINISHED WITH SAFTYYELLOW POWDER COAT PAINT FINISH. REFER TO SHEET A502FOR DETAILS.

- 150 mm DIA. CONCRETE FILLED METAL BOLLARD LOCATED ATMAN DOORS ARE TO BE INSTALLED 300mm FROM DOOR INOPEN POSITION NOT TO IMPEDE DOOR OPENING

- PIT SIZE TO BE CONFIRMED BY TENANT AND/OR DOCKLEVELER SUPPLIER .

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/11/2014 2:01:21 PM

C:\114023\114023-Air Cargo-Hamilton- 2014.04.30_htanious.rvt

A101

GROUND FLOORPLAN

SB

HT

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 200A101

1 GROUND FLOOR PLAN

FLOOR PLAN NOTESFLOOR PLAN GENERAL NOTES

5

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

UP UP

FD

FD

A A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

14

14

15

15

B B

C C

D D

E E

F F

G G

2

A301

CJ OFFICE@SF

200

1

A301

A1

B1

C1

D1

E1

F13

A302

16

16

13

13

8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 5750 9125 9125 8000

OUTSIDE FACE OF WALL TO OUTSIDE FACE OF WALL

120800

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

60860

STAIR NO.2

202

STAIR NO.1

201

202

2

A302

3

A301

A401

3

W3 W2 W2 W2 W2 W2

W3

WT5

WT5a

WT5a

WT5a

A501

1Sim

A501

14

GC OFFICE 1@SF

205

GC OFFICE 3@SF

207

GC OFFICE 2@SF

206

GC CORRIDOR@SF

208

A401

6

201

W3

W3

STAIR NO. 3

211

GC WOMEN'S W.R.@SF

209

GC MEN'S W.R. @SF

210

205

209

207

206

A701

4

210

A504

2

W1

OUTLINE OFCJ WASHROOMS BELOW

OUTLINE OFCELECTRICAL&FIRESUPPRESSION ROOM BELOW

OUTLINE OFEXIT CORRIDOR&VAULT ROOMBELOW

OUTLINE OF COOLER BELOW

W1

W1

W1

211212

GC MECH.ROOM

212

2

5

8

PROPOSEDLOCATION OFWASHROOMS.BYTENANT 8

WT5a8

10

9

exp

U/S ROOF DECK9500

MEMBRANE FLASHING

VAPOUR BARRIER

PRE FINISHED METALSCUPPER

WOOD BLOCKING

slope FLASHING MEMBRANE WRAPPED AROUNDWALL CAVITY & SEALED IN GUTTER

MODIFIED SEALANT

ANCHOR W/ FASTENERS& WATERBLOCK

6"

8"

6"

6"

SEAL ROOF VAPOUR BARRIER TOINSULATED METAL PANEL AS REQUIERD

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

7:1

9 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A102

SECOND FLOORPLAN

SB

HT

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 200A102

1 SECOND FLOOR

1 : 10A102

2 ROOF SCUPPER DETAIL

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

A A

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

14

14

15

15

B B

C C

D D

E E

F F

G G

2

A301

SLO

PE

SLO

PE

SLOPE SLOPE

SLO

PE

SLO

PE

SLOPE SLOPE

SLO

PE

SLO

PE

SLOPE SLOPE

SLO

PE

SLO

PE

SLOPE SLOPE

SLO

PE

SLO

PE

SLOPE SLOPE

SLO

PE

SLO

PE

SLOPE SLOPE

1

A301

A1

B1

C1

D1

E1

F13

A302

16

16

13

SLO

PE

SLO

PE

SLOPE SLOPE

8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 5750 9125 9125 8000

120000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

5000

60000

SLO

PE

SLO

PE

SLOPE SLOPE

2

A302

3

A301

PROVIDE SLOPEDINSUL. CRICKET ASREQUIRED TOPREVENT WATERPONDING @EQUIPMENTS. (TYP.)

RD RDRD

RD

RD

RDRD

RD

2

2

2

ROOF SCUPPER

ROOF SCUPPER

ROOF SCUPPER

ROOF SCUPPER

ROOF SCUPPERROOF SCUPPERROOF SCUPPERROOF SCUPPER

ROOF SCUPPER

ROOF SCUPPER

ROOF SCUPPER

2

ROOF SCUPPER ROOF SCUPPER ROOF SCUPPERROOF SCUPPER

2 2 2 2

2

ROOF SCUPPER

2

2

2

2222

2

2

2

RD

RD

RD

5 ROOF ACCESSHATCHW/STEEL ROOFLADDER

PREFABRICATEDMETAL CURB

PAINT OUTSIDE OF HATCHCOLOR TO MATCH ROOFING

PAINT UNDERSIDE OF ROOFHATCH COLOR TO MATCHCEILING

PRE-MANUFACTURED BYBILC0 - 36" x 36"

LAP AND SEALVAPOUR BARRIER TOCURBMETAL CLOSUREANGLE (TYP.)

16" WIDE STEEL LADDERWITH 2" X 1/4" STEEL PLATE& 3/8" DIA. RUNGS C/WPAINTED WELDEDSUPPORTS

PROVIDE SOLIDBLOCKING IN WALLFOR LADDER

TYPICAL ROOFCONSTRUCTION

8"

DRAIN SCREEN SECUREMENTBRACKET

STAINLESS STEEL GRAVELSTRAINER

SEAL ROOFING TO DRAINFLANGE ALL AROUNDOPENING

SEAL VAPOUR BARRIERTO DRAIN TYP.

PROVIDE SUNKEN AREAWITH TAPEREDINSULATION (2'X2')

6mm SLOPE TYPICAL

-2-PLY MODIFIEDBITUMINOUS ROOFINGSYSTEM-1/2" FIBREBOARD-MIN (R25) TAPERED RIGIDINSULATION AT ROOF DRAIN-VAPOUR BARRIER16mm DENS DECK PRIMER-METAL DECK DECK

MECHANICAL EQUIPMENTSEE MECHANICAL

RUBBER GASKET

PRESSURE TREATEDWOOD TO SUIT

PREFABRICATED METAL CURB

PREFINISHED METALFLASHING

1/2" EXTERIOR GRADEPLYWOOD

2" POLYISOCYANURATEINSULATION

VAPOUR BARRIER - SEALTO CURB TYP.

TYPICAL ROOF CONSTRUCTION

PIPE PENETRATION

MEMBRANE CAP

TYPICAL ROOF CONSTRUCTION

NOTE:

VAPOUR BARRIER SHALLBE SEALED AT EDGES

SEALENT

METAL HOOD WITH CLAMPING RING

MAMMOUTH PITCH POCKET FILLER

FILLER (QUICK SET GROUT)

51 51

U/S ROOF DECK9500

G

PREFINISHED METALFLASHING W/ WOODBLOCKING & SHIM TOSLOPE TOP

ROOFING TO EXTENDUP AND OVER TOPOF METAL PANEL

STRUCTURAL STEELFRAMING (REFER TOSTRUCTURAL DWGS.)

500

VAPOURBARRIER

METAL STUDS C/W BATTINSULATION

WOOD BLOCKING

WT2

VARIOUS

150

SEAL ROOF VAPOUR BARRIER TOINSULATED METAL PANEL ASREQUIERD

SLOPE

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

7:2

2 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A103

ROOF PLAN

SB

HT

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 200A103

1 ROOF PLAN

1 : 15A103

3 SEC. DET. AT ROOF ACCESS HATCH 1 : 10A103

5 SECTION DETAIL AT ROOF DRAIN 1 : 10A103

4 SEC. DET. AT ROOF MECH. CURB 1 : 5A103

2 VENT STACK DETAIL 1 : 10A103

6 PARAPET DETAIL

NO. ISSUED DATE

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

ABCDEFG1

A301

A1B1C1D1E1F1

3'-6"H PAINTED GALVANIZEDMETAL GUARDRAIL. REFER TOSITE PLAN FOR EXTENT

PREFINISHED INSULATEDMETAL PANEL COLOUR 1

W1 W1 W1 W1

DOUBLE GLAZED - IN PREFIN.THERMALLY BROKENALUMINUM FRAME CLEARANODIZED

WALL MOUNTED LIGHTFIXTURE. REFER TO ELECT.DWGS. FOR HEIGHTS

W1W1W1W1

PREFINISHED INSULATEDMETAL PANEL COLOUR 2

ROOF SCUPPER

2 2 2

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

123456789101112141516 13

3

A301

W2

CW1

W2 W2 W2 W2 W3

DOUBLE GLAZED - IN PREFIN.THERMALLY BROKENALUMINUM FRAME CLEARANODIZED

DOUBLE GLAZED - IN PREFIN.THERMALLY BROKENALUMINUM FRAME CLEARANODIZED

PREFINISHED METAL CAPFLASHING

W3

PREFINISHED INSULATEDMETAL PANEL COLOUR 1

PREFINISHED FLASHING BANDMOUNTED AT 4900MM A.F.F.

PREFINISHED INSULATEDMETAL PANEL COLOUR 2d ROOF SCUPPER 3

3

2222 2

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

1 2 3 4 5 6 7 8 9 10 11 12 14 15

T/O LOADING DOCK-1220

16133

A301

ARCHITECTURAL INSULATEDPRECAST CONCRETE PANEL

PAINTED HM DOOR ANDFRAME. TYP.

PREFINISHED METAL CANOPYCONTINUOUS ABOVE DOCKDOOR

PREFINISHED INSULATEDMETAL PANEL COLOUR 1

ALUMINUM EXTERIORWINDOWS

DOUBLE GLAZED - IN PREFIN.THERMALLY BROKENALUMINUM FRAME CLEARANODIZED

DOUBLE GLAZED - IN PREFIN.THERMALLY BROKENALUMINUM FRAME CLEARANODIZED

CW2 CW1

W3

WALL MOUNTED LIGHTFIXTURE. REFER TO ELECT.DWGS. FOR HEIGHTS

W3

PREFINISHED INSULATEDMETAL PANEL COLOUR 2PREFINISHED FLASHING BAND

MOUNTED AT 4900MM A.F.F.

PREFINISHED METAL CAPFLASHING

HYDRAULICLEVELER,BUMPER,COVERPLATE&VEHICLE RESTRAINT(TYP.)

LIGHT (TYP.)

(6)SCISSOR LIFT W/VEHICLE

RESTRAINT&BUMPERBY GENERALCONTRACTOR(TYP.)

d

d

ROOF SCUPPER

ROOF SCUPPER

3

2 2 2 2 2

7

3

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A B C D E F GA1 B1 C1 D1 E1 F1

PREFINISHED METAL CAPFLASHING

WALL MOUNTED LIGHTFIXTURE. REFER TO ELECT.DWGS. FOR HEIGHTS

PREFINISHED METAL CANOPYCONTINUOUS ABOVE DOCKDOOR

3'-6"H PAINTED GALVANIZEDMETAL GUARDRAIL. REFER TOSITE PLAN FOR EXTENT

PAINTED HM DOOR ANDFRAME. TYP. PREFINISHED FLASHING BAND

MOUNTED AT 4900MM A.F.F.

PREFINISHED INSULATEDMETAL PANEL COLOUR 1

ROOF SCUPPER

2 2 2

1

A304

NOCA-1

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 200

06/1

1/2

014 1

0:2

8:1

2 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A201

EXTERIORELEVATIONS

SB

HT

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 200A201

3 EAST ELEVATION

1 : 200A201

1 NORTH ELEVATION

1 : 200A201

4 SOUTH ELEVATION

1 : 200A201

2 WEST ELEVATION

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A B C D E F GA1 B1 C1 D1 E1 F1

T/O LOADING DOCK-1220

CJ OFFICE@SF

200

A303

4

CARGOJETWAREHOUSE

100

A302

3Sim

HEAVY-DUTYBARRIER RAIL(TYP.) SEEDETAILS ON A502

2 HR. FRR STAIRENCLOSURE BEYOND

WT3WT2

EXIT CORRIDOR BEYOND

WT2

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

1 2 3 4 5 6 7 8 9 10 11 12 14 15 1613

GENERAL CARGOWAREHOUSE

105

COOLER

106

A303

3A303

2

CJ OFFICE@SF

200STAIR NO.1

201 STAIR NO.2

202CARGOJETWAREHOUSE

100

EXIT CORRIDOR

117

A303

1

HEAVY-DUTY BARRIERRAIL (TYP.) SEEDETAILS ON A502

GC OFFICE @GF

108

GC OFFICE 1@SF

205

CARGOJET DOCUM.

101

2 HR. FRR STAIRENCLOSURE

2 HR. FRR STAIRENCLOSURE

d

41158

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A B C D E F GA1 B1 C1 D1 E1 F1

T/O LOADING DOCK-1220

VESTIBULE

112

A302

3Sim

A302

1

CARGOJETWAREHOUSE

100HEAVY-DUTY BARRIERRAIL (TYP.) SEEDETAILS ON A502

WT3WT3

WT2

WT 1

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 200

06/1

1/2

014 1

0:2

8:1

8 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A301

BUILDINGSECTIONS

SB

HC

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 200A301

2 BUILDING SECTION THROUGH CARGOJET OFFICE

1 : 200A301

1 BUILDING SECTION THROUGH WAREHOUSE

1 : 200A301

3 BUILDING SECTION THOUGH LOADING DOCK

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

G

T/O LOADING DOCK-1220

GALVANIZED STEELANGLE - SEE STRUCT.DWGS

R15 (75mm) INSULATIONTO EXTEND 600mmBELOW GRADE

GALVANIZED STEELANGLE EMBEDDEDSUPPLIED BY DOCKMANUF, INSTALLED BY GC( ALL AROUND THE PIT)TYP.

REFER TO STRUCTURALDWGS FOR FOUNDATIONCONFIGURATION

SEE STRUCT. DWGS FORFOOTINGS. TYP.

PREFINISHED INSULATEDMETAL VERTICAL LIFT DOORC/W WEATHERSTRIPPING ALLAROUND

CONT. BENT PLATE JAMBBEYOND

INFLATABLE DOCKSHELTER

CONT. BENT PLATEHEAD TRIM

METAL PANEL CANOPY ONGALVANIZED STEEL ANGLEFRAME. REFER TO STRUCT.DWGS.

CONTINUOUS PREFINISHEDMETAL BASE TRIM

FLEXIBLE MEMBRANEFLASHING

STEEL PLATES EMBEDDED INPRECAST CONCRETE PANEL. FIELDVERIFY

GALVANIZED CONTINUOUS BASECHANNEL BY WALL PANEL SUPPLIER

PREFINISHED METAL CAP FLASHING C/WSTARTER STRIP SLOPED TO DRAIN

ROOFING TO EXTEND UP AND OVERTOP OF METAL PANEL

PREFINISHED METAL WALL PANELCAP. TYPICAL

STEEL COLUMN BEYOND -SEE STRUCTURAL DWGS

STEEL BEAM - SEESTRUCTURAL DWGS

HSS GIRT REFER TO STRUCT.DWGS

500

4930

TO

P O

F P

RE

CAST

4570

1220

460

WT 1

WT2

VAPOUR RETARDER

A103

6

CONCRETE FOUNDATION WALL -REFER TO STRUCT. DWGS.

NOTE:PIT SIZE TO BECONFIRMED BY DOCKLEVELER SUPPLIER

DOOR SEAL

HYDRAULIC DOCK LEVELER BLUEGIANT MODEL HA & STRONG ARMSVR303 AND VEHICLE RESTRAINTOR APPROVED EQUAL BY GENERALCONTRACTOR

CO

NFIR

ME

W/D

OO

R M

AN

UFAC

TO

RY

3048

1220

100

965

457

915

STEEL BRACESEE STRUCTURAL DWGS.

HSS GIRT REFER TO STRUCT.DWGS

SLOPE

SLOPE

OUTLINE OF O/H DOORIN OPEN POSITION

HEAVY-DUTY BARRIER RAIL(TYP.) SEE DETAILS ONA502-REFER TO PLAN FORLOCATION

VEHICLE RESTRAINT

VEHICLE BUMPER

CONCRETE FILLED METALBOLLARD-REFER TO PLAN FORLOCATION

WOOD BLOCKING

METAL STUDS C/W BATTINSULATION

100

CONFIRMED W/ DOCK SUPPLIER

1829

CO

FIR

MED

W/D

OC

K S

UP

PLIE

R

495

d

VESTIBULE

112

EXTERIOR

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

G

T/O LOADING DOCK-1220

CARGOJETWAREHOUSE

100

WT 1

WT2

PREFINISHED METAL CAPFLASHING C/W STARTERSTRIP SLOPED TO DRAIN

ROOFING TO EXTEND UP AND OVERTOP OF METAL PANEL

VAPOUR RETARDER

METAL PANEL CANOPYON GALVANIZED STEELANGLE FRAME. SEESTRUCT. DWGS.

CONTINUOUSPREFINISHED METALBASE TRIM

FLEXIBLE MEMBRANEFLASHING

STEEL PLATES EMBEDDED INPRECAST CONCRETE PANEL. FIELDVERIFY

GALVANIZED CONTINUOUS BASECHANNEL BY WALL PANELSUPPLIER

RT1

EXTERIOR

SLOPE PIT FLOOR 1/2 DEGREE

PIT

DE

PTH

(TO

BE

CO

NFIR

M W

/TE

NA

NT)

762

DRAIN HOLES (3)

GALVANIZED STEELANGLE - SEE STRUCT.DWGS

R15 (75mm) INSULATION TO EXTEND600mm BELOW GRADE

STEEL ANGLE EMBEDDED ALLAROUND THE PIT (TYP.)SUPPLIED AND INSTALLED BYGENERAL CONTRACTOR

REFER TO STRUCTURAL DWGS FORFOUNDATION CONFIGURATION

PIT LENGTH (TO BE CONFIRM W/TENANT)

3966

SEE STRUCT. DWGS FOR FOOTINGS.(TYP.)

HSS GIRT REFER TO STRUCT.DWGS

OPEN WEBBED STEELJOIST BEYONDSEE STRUCTURALDWGS.

460

1220

5300

4200

500

VAPOUR BARRIER TOEXTEND UP METAL PANELAND SEAL

STEEL BEAM - SEE STRUCT.DWGS

STEEL COLUMN BEYOND -SEE STRUCT. DWGS

360 100

HSS GIRT - REFER TOSTRUCT. DWGS.

A103

6Sim

PREFINISHED INSULATEDMETAL VERTICAL LIFTDOOR C/WWEATHERSTRIPPING ALLAROUND

CONT. BENT PLATEJAMB BEYOND

CONT. BENT PLATEHEAD TRIM

DOOR SEAL

SLOPE

OUTLINE OF O/H DOORIN OPEN POSITION

VEHICLE RESTRAINT

VEHICLE BUMPER

7

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A

CARGOJETWAREHOUSE

100

WT2

400

EXTERIOR

SLOPE

PREFINISHEDMETAL CAPFLASHING C/WSTARTER STRIPSLOPED TO DRAIN

ROOFING TOEXTEND UP ANDOVER TOP OFMETAL PANEL

VAPOUR RETARDERVAPOUR BARRIERTO EXTEND UPMETAL PANEL ANDSEAL

STEEL BEAM -SEE STRUCT.DWGS

STEEL COLUMNBEYOND - SEESTRUCT. DWGS

SLOPERT1

ELECTRICALLY OPERATEDHIGH SPEED ROLL-UPDOOR

HSS GIRT REFERTO STRUCT. DWGS

HSS GIRT REFERTO STRUCT. DWGS

SEE STRUCT. DWGS FORFOOTINGS. (TYP.)

R15 (75mm) INSULATION TOEXTEND 600mm BELOW GRADE

100 300

CONCRETE FILLEDMETAL BOLLARD

STEEL CHANNEL OR BENTPLATE AT JAMBS &HEADER - MISC. METALSUPPLIER TO PROVIDEWELD PLATES FORATTACHMENT

500

4200

423

CO

NFIR

ME

W/D

OO

R M

AN

UFAC

TO

RY

4877

150mm DIA. WEEPING TILESCONTINUOUSAROUND WAREHOUSE c/w FILTERCLOTH, TO CONNECT TO STORMSYSTEM B/O CONCRETE FOOTING

STEEL ANGLE. SEESTRUCT.DWGS

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 20

06/1

1/2

014 1

0:2

8:2

0 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A302

WALL SECTIONS I

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 20A302

3 WALL SECTION @ LOADING DOCK DOOR W / LEVELER 1 : 20A302

2 WALL SECTION @ LOADING DOCK W/ SCISSOR LIFT 1 : 20A302

1 WALL SECTION @ RAPID-ROLL DOOR

NO. ISSUED DATE

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

1

STEEL FRAMING.SEE STRUCTURALDWGS.

ROOFING TO EXTEND UP ANDOVER TOP OF METAL PANEL

VAPOUR RETARDER

WT2

RT1

CARGOJET DOCUM.

101

EXTERIOR

STEEL BEAM. SEESTRUCT. DWGS.

PREFINISHED METAL CAPFLASHING C/W STARTERSTRIP SLOPED TO DRAIN

400

500

4200

5300

SLOPE

*STAIR WALLS TO BESUPPORTED BY STEEL MISC.STRUCTURE;DESIGNED BY MISC. METALSCONTRACTOR'S ENGINEER

HSS GIRT SEESTRUCT. DWGS

STAIR NO.1

201

CONTINUOUSPREFINISHEDMETAL BASE TRIM

CONTINUOUS CAULK

CONCRETE FOUNDATION WALL.REFER TO STRUCT. DWGS

CONCRETE FOOTING -SEE STRUCT. DWGS

R15 (75mm) INSULATION TOEXTEND 600mm BELOW GRADE

12 mm COMPRESSIBLEJOINT FILLER

A103

6Sim

150mm DIA. WEEPINGTILES CONTINUOUSAROUND WAREHOUSEc/w FILTER CLOTH, TOCONNECT TO STORMSYSTEM

B/O CONCRETE FOOTING

(WT9) 2 HR FRRSHAFT WALL U/SOF STAIR

(WT9) 2HR. FIRE RATEDSHAFT WALL U/S OF STAIR.ADD 3RD. LAYER FIRERATED DRYWALL 16mm

STEEL FRAMING. SEESTRUCT. DWGS.

STEEL BRACING SEESTRUCT. DWGS

1561270184300100

FIRE STOPSEALANT

WT5

WT5

CJ OFFICE@SF

200

400 1700

CARGOJET DOCUM.

101

GRADE

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A

ROOFING TO EXTENDUP AND OVER TOP OFMETAL PANEL

VAPOUR RETARDER

W2

RT1

PREFINISHEDMETAL CAPFLASHING C/WSTARTER STRIPSLOPED TO DRAIN

MOTORIZED O/HDRIVE THROUGHDOOR -HORIZONTAL LIFT

5300

4200

CARGOJETWAREHOUSE

100EXTERIOR

CJ OFFICE@SF

200

400

2HR.FRR. THIN-FILMINTUMESCENT COATINGREFER TO SHEET A003

FIRE STOP SEALANT

500

1800

CO

NFIR

ME

W/W

IND

OW

MA

NU

FA

CTO

RY

1500

900

1642

CO

NFIR

ME

W/D

OO

R M

AN

UFAC

TO

RY

3658

100 300

STEEL BEAM-SEESTRUCTURALDWGS.

HSS GIRT. SEESTRUCTURALDWGS.

HSS GIRT. SEESTRUCTURALDWGS.

OUTLINE OF O/HDOOR ( HORIZONTALLIFT) IN OPENPOSITION

OUTLINE OF O/HDOOR ( RAPID-ROLL)IN OPEN POSITION

CONCRETEFOOTING - SEESTRUCT. DWGS

R15 (75mm)INSULATION TOEXTEND 600mmBELOW GRADE

SLOPE

STEEL CHANNEL OR BENTPLATE AT JAMBS &HEADER - MISC. METALSUPPLIER TO PROVIDEWELD PLATES FORATTACHMENT

A103

6Sim

150mmCONCRETEFILLED METAL

150mm DIA. WEEPING TILES CONTINUOUSAROUND WAREHOUSE c/w FILTER CLOTH,TO CONNECT TO STORM SYSTEM

B/O CONCRETE FOOTING

STEEL ANGLE. SEESTRUCT.DWGS

W2

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

8

EXIT CORRIDOR

117

CARGOJETWAREHOUSE

100

OPEN WEBBED STEEL JOISTBEYOND. SEE STRUCTURALDWGS.

WT3

RT1

WT3a

4200

5300

WT3

GENERAL CARGOWAREHOUSE

105

FIRE STOP SEALANT ATBOTH SIDESEXTEND GYP. BD INTO

DECK FLUTES. LAPVAPOUR BARRIER OVERTOP OF GBYP.BD. ANDSEAL

FIRE STOP SEALANT

STEEL BEAM-SEESTRUCT. DWGS

WT5a

CONCRETEFILLED METALBOLLARD

HEAVY-DUTYBARRIERRAIL-REFERTO A505

LINE OF PARAPETBEYOND

STEEL BEAM-SEESTRUCT. DWGS

FOR 2 HR. FIRE RATED CEILINGASSEMBLY PROVIDE:-19 STRUCTURAL CEMENT BOARD TYPEARMOROC OR EQUAL-15.9mm FIRE RATED GYPSUM BOARD- 203mm STEEL JOIST-15.9mm FIRE RATED GYPSUM BOARD-15.9mm FIRE RATED GYPSUM BOARD

FOR 1 HR. FRR FLOOR ASSEMBLY AT(ELECTRICAL,FIRESUPPRESION,D.GOODS ROOMS)PROVIDE:-19 STRUCTURAL CEMENT BOARD TYPEARMOROC OR EQUAL- 203mm STEEL JOIST-15.9mm FIRE RATED GYPSUM BOARD

SLOPESLOPE

*STORAGE ABOVE IS PROHIBITED

2750

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

16

STEEL FRAMING. SEESTRUCTURAL DWGS

ROOFING TO EXTEND UP ANDOVER TOP OF METAL PANEL

VAPOUR RETARDER

WT2

RT1

WT2

GC OFFICE @GF

108

EXTERIOR

PREFINISHED METAL CAPFLASHING C/W STARTER STRIPSLOPED TO DRAIN

PREFINISHEDMETAL WALLPANEL CAP.TYPICAL

500

1800

CO

NFIR

ME

W/W

IND

OW

MA

NU

FA

CTO

RY

1500

900

2900

CO

NFIR

ME

W/W

IND

OW

MA

NU

FA

CTO

RY

1500

900

400

CONTINUOUSPREFINISHEDMETAL BASE TRIM

CONTINUOUS CAULK

CONCRETE FOUNDATIONWALL. REFER TO STRUCT.DWGS

CONCRETEFOOTING - SEESTRUCT. DWGS

R15 (75mm)INSULATION TOEXTEND 600mmBELOW GRADE

12 mm COMPRESSIBLEJOINT FILLER

FIRE STOP SEALANT

GC OFFICE 1@SF

205

A103

6Sim

150mm DIA. WEEPING TILES CONTINUOUSAROUND WAREHOUSE c/w FILTER CLOTH,TO CONNECT TO STORM SYSTEM

B/O CONCRETE FOOTING

W1

W1

STEEL FRAMING. SEESTRUCTURAL DWGS2 HR. FIRE RESISTANCERATING REQUIRED(REFER TO SHEETA003)

SUSPENDEDACOUSTIC CEILINGTILE IN T-BAR GRID

SUSPENDEDACOUSTIC CEILINGTILE IN T-BAR GRID

GRADE

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 20

06/1

1/2

014 1

0:2

8:2

3 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A303

WALL SECTION II

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 20A303

3 WALL SECTION @ CARGOJET DOCM. 1 : 20A303

4 WALL SECTION @ CARGOJET OFFICE 1 : 20A303

2 WALL SECTION @ TENANT DEMISING WALL 1 : 20A303

1 WALL SECTION @ GENERAL CARGO

NO. ISSUED DATE

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

T/O GROUND FLOOR0

2FOR CEILING ASSEMBLYPROVIDE:-16mm GYPSUM BOARD-19mm PLYWOOD- 203mm STEEL JOIST-15.9mm GYPSUM BOARD

WT2 WT8

EXTERIOR

3200

STEEL FRAMING. SEESTRUCT. DWGS.

SLOPE

CONTINUOUSPREFINISHED METALBASE TRIM

CONTINUOUSCAULK (TYP.)

CONCRETEFOUNDATION WALL.SEE STRUCT.DWGS

12 mm COMPRESSIBLEJOINT FILLER

300100

SLAB ON GRID

16

19

203

16

3184

400

SUSPENDEDACOUSTIC CEILINGTILE IN T-BAR GRID

CJ MEN'S W.R @GF

104

150mm DIA. WEEPINGTILES CONTINUOUSAROUND WAREHOUSE c/wFILTER CLOTH, TOCONNECT TO STORMSYSTEM

B/O CONCRETEFOOTING

CONCRETE FOOTING -SEE STRUCT. DWGS

R15 (75mm)INSULATION TOEXTEND 600mm BELOWGRADE

*STORAGE ABOVE IS PROHIBITED

T/O GROUND FLOOR0

B

3048

-19mm STRUC. CEMENTBOARD TYPE ARMOROCOR EQUAL-152mm STEEL JOIST-PREFIN. ALUMINUMCEILING TILES. COLOURTO MATCH CURTAIN WALLMULLEON

CARGOJETVESTIBULE

121

CW2

STEEL FRAMING. SEE STRUCT. DWGS.

CARGOJET DOCUM.

101

CW3

300 100

400

150mm DIA. WEEPING TILESCONTINUOUS AROUNDWAREHOUSE c/w FILTERCLOTH, TO CONNECT TOSTORM SYSTEM

B/O CONCRETEFOOTING

SLOPE

R15 (75mm)INSULATION TOEXTEND 600mm BELOWGRADE

CONCRETE FOOTING -SEE STRUCT. DWGS

EXTERIOR

WT2

SLAB ON GRID

*STORAGE ABOVE IS PROHIBITED

GRADE

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 20

06/1

1/2

014 1

0:2

8:2

4 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A304

WALL SECTION III& SECTION

DETAIL

SB

HT

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 20A304

1 WALL SECTION @ CARGOJET W.R.10

1 : 20A304

3 WALL SECTION @ CARGOJET VESTIBULE3

NO. ISSUED DATE

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

UP

FD

FD

UP

FD

FD

A

1 2

B

1

A301

A1

CARGOJET DOCUM.

101

STAIR NO.1

102

A503

3

WT5

102a

101b102b

WT2

WT4

CW2WT2

WT2

400

5000

5000

400 8000

3427 184

400

1452

6939

400 5003 2997 150

400 8150

3121

101a

3

A304

CW3

CW4

6 6

6

6

(WT9) 2 HR SHAFTWALL U/S OF STAIR TOBE EXTENDED TO THEINTERIOR FACE OF IMPPROVIDE FIRE STOPSEALANT

400 4723WT9

400

1610

WT8WT8

400

400

STEEL BRACINGABOVE SEESTRUCT.DWGS

OUTLINE O/HEAVY-DUTYBARRIERRAIL (TYP.)

WT4

STEEL BRACINGABOVE SEESTRUCT.DWGS

100 300 4000 4000

MIN.

60

A

15

B

C

D

1

A301

A1

B1

C1

16

GC OFFICE @GF

108

GC DOCUM.@GF

109

GC MEN'S W.R.@GF

111

GC WOMEN'SW.R.@GE

110

8000 400

400

5000

5000

5000

5000

5000

5000

400

111

108b

110

109b

109a

108a

109c

119b

CW1WT2

WT2

W1

WT2

W1

WT2

W1

WT2

W1

WT2

WT2

WT4

WT7WT6

WT6

WT6

CW1WT2

8083

5397

1528

200

3980 4228

152

248

5188

124

9596

8208

RECESSED FIRE ALARMANNUNCIATOR BOX STAIR NO.3

119119a

OUTLINE OF COUNTERSCALE (1500x1500 mm)

WT7a

2

2

0

2

564

CONFIRME W/CURTAIN WALL MANUFACTORY

4936 2250 250 400

WT4

WT7a

WT9

(WT9) 2 HR SHAFTWALL U/S OF STAIR TOBE EXTENDED TO THEINTERIOR FACE OF IMPPROVIDE FIRE STOPSEALANT

250

400

400

738

3525

738

738

3525

738

738

3525

738

251

4749

738

3525

738

5000

400

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

1532

CONFIRME W/CURTAIN WALL MANUFACTORY

4936 1532 300 100

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

4365 3543 300 100

250

284

7699

100

6399 1509 400

WT5

66

FIRE STOP SEALANTAT BOTH SIDES

A

1 2 3 4 5 6 7

B

2

A301

1

A301

A1

A503

6

CJ OFFICE@SF

200

WT5

WT5

202

WT2

STAIR NO.1

201

A503

4

400 8000 8000 8000 8000 8000 8000

W2W2WT2

W2WT2

W2WT2

W3WT2 WT2

W2WT2

WT5a

WT5a

WT5a

WT2

W3WT2

46440

10392

46440

1680

CONFIRME W/WINDOW MANUFACTORY

5840 480

400

5000

5000

WT5a

8

201

FIRE STOP SEALANTAT BOTH SIDES

FIRE STOPSEALANT ATBOTH SIDES

FIRE STOP SEALANTAT BOTH SIDES

WT8

WT8

100 300 1720

CONFIRME W/WINDOW MANUFACTORY

5840 440500

CONFIRME W/WINDOW MANUFACTORY

7000 500500

CONFIRME W/WINDOW MANUFACTORY

7000 500500

CONFIRME W/WINDOW MANUFACTORY

7000 500500

CONFIRME W/WINDOW MANUFACTORY

7000 500500

CONFIRME W/WINDOW MANUFACTORY

7000 500

STEEL FRAMING. SEESTRUCTURAL DWGS.

CARGOJETWAREHOUSE

100

STAIR NO.2

202

WT5

WT2

8

PROPOSEDLOCATION OFWASHROOMS.BYTENANT

7 8

F

G

F1

3

A302

3

A301

VESTIBULE

112

112e

112d

112c

112f

112a112b

WT 1

WT3

WT3

WT3

117 7883 117

8000

5000

5000

117

1704

CO

NFIR

ME

W/D

OO

R M

AN

UFAC

TO

RY

3658

4638

460

7765

10027

OUTLINE O/HEAVY-DUTYBARRIER RAIL(TYP.)

500

CO

NFIR

ME W

/DO

OR

MAN

UFA

CTO

RY

TYP.

2000 4000

TYP.

2000

117

1704

3658

2661

1977

460

FIRE STOP SEALANTAT BOTH SIDES

A

8

B

C

1

A301

A1

B1

EXIT CORRIDOR

117

5000

5000

5000

5000

1000

117b

117a

117c

WT5a

WT3a

WT5a

WT5a

WT5a

WT2

1700

400

15000

2133

2867

844

156

1449

PROPOSED LOCATIONOF CHARGING STATIONSEE ELLEC.DWGS

MAINTAINING MIN.3'- 8"(1100mm)CLEAR TYP.

EQ EQ

1649

1160 540

400

15000

156

4844

744

100

GENERAL CARGOWAREHOUSE

105

CARGOJETWAREHOUSE

100

FIRE STOP SEALANT ATBOTH SIDES

FIRE STOP SEALANTAT BOTH SIDES

A

15

B

C

D

1

A301

A1

B1

C1

16

GC OFFICE 3@SF

207

GC OFFICE 2@SF

206

GC OFFICE 1@SF

205

GC CORRIDOR@SF

208

STAIR NO. 3

211

207

205

209

WT5

WT5

WT5

WT2

WT2

WT6b

WT6

WT7

WT7

WT7

WT2

WT2

10453

156 144 8000 300

7642

3911

4294

5834

8444

156 144 6491

15242641

W1

W1

W1

W3

2

5

W1

STEEL ROOF LADDER

ROOF ACCESSHATCH ABOVE

HVAC DUCTS. SEEMECH.DWGS

WT4

212

WT6b

WT4bWT4b

WT4b

9

144 321 2651 3519

450

124

1584

4483

2974

1558 6898

WT6

WT8 WT8

RWLSEE MECH.DWGS

HVAC DUCTS. SEEMECH.DWGS

908

1080

CONFIRME W/WINDOW MANUFACTORY

5840 1080

7542

284

1524

400

738

3525

738

738

3525

738

738

3525

738

5000

5000

775

3525

700

WT8

206

211

210

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

CO

NFIR

ME

W/W

IND

OW

MAN

UFA

CTO

RY

1080

CONFIRME W/WINDOW MANUFACTORY

5840 1080

9679

EQ EQ

FIRE STOPSEALANT ATBOTH SIDES

FIRE STOPSEALANT ATBOTH SIDES

FIRE STOPSEALANT ATBOTH SIDES

FIRE STOPSEALANT ATBOTH SIDES

WT5

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 100

06/1

1/2

014 1

0:2

8:2

9 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A401

ENLARGEDPLANS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 100A401

1 ENLARGED CARGOJET DOCUM. PLAN 1 : 100A401

4 ENLARGED GENERAL CARGO PLAN

1 : 100A401

3 ENLARGED CARGOJET SECOND FLOOR PLAN

1 : 100A401

2 ENLARGED VESTIBULE PLAN

1 : 100A401

5 ENLARGED EXIT CORRIDOR PLAN 1 : 100A401

6 ENLARGED PROPOSED GC SECOND FLOOR PLAN

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

A

15

B

C

D

A1

B1

C1

16

GC OFFICE @GF

108

GC MEN'S W.R.@GF

111

GC WOMEN'SW.R.@GE

110

GC DOCUM.@GF

109

ACT13350

ACT12750

2HR. FRR GYP.BOARDCEILING U/S OF STAIR

ACT13350

STAIR NO.3

119

GC MANAGER OFFICE@GR

120

ACT12750

EXP

2

2

2

2

2

2

2

2

2

A

15

B

C

D

A1

B1

C1

16

GC MEN'S W.R. @SF

210

GC WOMEN'S W.R.@SF

209

GC OFFICE 3@SF

207

GC OFFICE 2@SF

206

GC OFFICE 1@SF

205

GC CORRIDOR@SF

208

STAIR NO. 3

211

ACT13000

ACT13000

ACT12750

ACT12750

ACT13000

EXP

2

2

2

2

2

2

2

2

5

EXP

ROOF ACCESSHATCH ABOVEW/STEEL ROOFLADDER

HVAC DUCTS. SEEMECH.DWGS

8

1. BEGIN LAYOUT OF CEILING TILES AT CENTER OFROOMS AS SHOWN

2. CENTER LIGHT FIXTURES ON CEILING TILE

3.

GENERAL NOTES

SEE ELECTRICAL DWGS. FOR DETAILED LIGHTING LAYOUT

4. SEE MECHANICAL DWGS. FOR DETAILED SUPPLY& RETURN LAYOUT

EXHAUST FAN

ACT SUSPENDED ACOUSTIC CEILING TILE

CEILING LEGEND

ACT1LEVEL

600X1200 mm CEILING MOUNTED FLUORESCENT FIXTURE

30X1200 mm WALL/CEILING MOUNTED FLUORESCENT LIGHT

150mm DIA. RECESSED FLUORESCENT DOWN LIGHT

SUPPLY & RETURN DIFFUSERS

2

2

C

B1

C1

ACT12750

ACT12750

CJ WOMEN'SW.R.@GF

103

CJ MEN'S W.R @GF

104

CJ UNIVERSALW.R.@GF

122ACT12750

2

B

PREFIN. ALUMINUMCEILING TILES.COLOUR TO MATCHCURTAIN WALLMULLEON

CARGOJETVESTIBULE

121

2

F

G

F1

ELECTRICAL ROOM

116

FIRE SUPPRESSION

115

GB2750

GB2750

A

8

B

C

A1

B1

C1

GB2750

VAULT

113

EXIT CORRIDOR

117

GB2750

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:3

2 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A402

REFLECTEDCEILING PLANS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 100A402

1 RCP GENERAL CARGO AT GROUND FLOOR 1 : 100A402

2 RCP GENERAL CARGO AT SECOND FLOOR 1 : 100A402

4 RCP CARGOJET W.R. AT GROUND FLOOR

10

1 : 50A402

3 RCP CARGOJET VEST. AT GROUND FLOOR

3

1 : 100A402

6 RCP ELECTRICAL&FIRE SUPPRESION ROOM

1 : 100A402

5 RCP EXIT CORRIDOR&VAULT

NO. ISSUED DATE

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

A

1

STAIR NO.1

102

EXTERIORWT2

WT2

WT8

100 300 184

100

300

2 HR. FIRERESISTANCE RATINGREQUIRED(SEE STRUCT.DWGS)

STEEL BRACES (REFER TOSTRUCT. DWGS.)

169

2184

EXTEND STAIR TO FACEOF STRUCTURALBRACES.STAIR WALLS TO BESUPPORTED BY STEELMISC. STRUCTURE; STAIRMANUFACTURER TOPROVIDE

2

B

CARGOJETWAREHOUSE

100

EXTERIOR

WT4

WT4

WT2

WT2

OUTLINE O/ HEAVY-DUTYBARRIER RAIL (TYP.)

FIRE STOPSEALANT ATBOTH SIDES

100 300 334

25

2 HR. FIRE RESISTANCERATING REQUIRED(SEE STRUCT.DWGS)

300

184

25

CARGOJETVESTIBULE

121

25

2

C

EXTERIOR

WT2

WT8

100 300 142

STRUCTURAL STEELFRAMING (SEE STRUCT.DWGS.)

WT8

WT8

CJ WOMEN'SW.R.@GF

103

WT8

834

G

CARGOJETWAREHOUSE

100

FIRE SUPPRESSION

115

EXTERIOR

WT4a

WT2

100k

FIRE STOPSEALANT ATBOTH SIDES

360

100

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

305

200

25

184

CONFIRME W/DOOR MANUFACTORY

354

460

150mm DIM. CONCRETEFILLED METAL BOLLARDLOCATED ASDIMENSIONED,FROMBOTH SIDES (TYP.)

FRAMED OPENINGSEE STRUC.DWGS

8

F

CARGOJETWAREHOUSE

100

VESTIBULE

112

WT3

WT3

WT8b

STRUCTURAL STEELFRAMING (SEESTRUCT. DWGS.)

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

25

204

204

25

188

188

25

25OUTLINE O/HEAVY-DUTYBARRIER RAIL(TYP.)

25

GENERAL CARGOWAREHOUSE

105

259 277

WT3

15

D

GC DOCUM.@GF

109

GENERAL CARGOWAREHOUSE

105

EXTERIOR

WT4

WT2

WT8cWT8c

194

300

100

226226

109b

FIRE STOPSEALANT ATBOTH SIDES

G

13

GENERAL CARGOWAREHOUSE

105 WT2

WT2

EXTERIOR

STRUCTURAL STEELFRAMING (SEE STRUCT.DWGS.)

300 100

360

100

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

460

400

25

A

GENERAL CARGOWAREHOUSE

105

EXIT CORRIDOR

117

WT2

105k

WT5aFRAMED OPENING (SEESTRUCT. DWGS.)

25

400

156

CONFIRME W/DOOR MANUFACTORY

428

FIRE STOP SEALANTAT BOTH SIDES

EXTERIOR

TYP.

300

TYP.

300

CONFIRME W/DOOR MANUFACTORY58

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

150mm DIM.CONCRETE FILLEDMETAL BOLLARD ATBOTH SIDESLOCATED ASDIMENSIONED (TYP.)

A

8

EXIT CORRIDOR

117

CARGOJETWAREHOUSE

100

WT3a

WT2

100t

STRUCTURAL STEELCOLUMN (SEESTRUCT. DWGS.)

CONFIRME W/DOOR MANUFACTORY

637

100

300

167

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

25

FIRE STOPSEALANT ATBOTH SIDES

WT8dWT8c

300

187 162

195

300

25

150mm DIM.CONCRETE FILLEDMETAL BOLLARD ATBOTH SIDESLOCATED ASDIMENSIONED (TYP.)

FRAMEDOPENING(SEESTRUC.DWGS)

FRAMEDOPENING(SEESTRUC.DWGS)

CONFIRME W/DOOR MANUFACTORY

220

8

EXIT CORRIDOR

117CARGOJETWAREHOUSE

100

WT3a

WT3

WT5a

OUTLINE O/ HEAVY-DUTYBARRIER RAIL (TYP.)

L CASING BEAD

FIRE STOP SEALANT

3

G

BACK ROD &SEALANT. TYPBOTH SIDES

PREFINISHEDMETAL CLOSURE

CARGOJETWAREHOUSE

100

EXTERIOR DOCK DOOR SEAL

O/H DOCKDOOR

250

210

CONFIRME W/DOOR MANUFACTORY

152

CONFIRME W/DOOR MANUFACTORY

781

STEEL COLUMN - REFERTO STRUCT. DWGS

STEEL PLATEJAMB BY O/HDOORSUPPLIER

OUTLINE OFPIT BELOW.COFIRMW/TENANT

360

100

460

3

FRAMED OPENING(SEE STRUC.DWGS)

D

16

WT2

WT2

119b

EXTERIOR

STRUCTURAL STEELFRAMING (SEE STRUCT.DWGS.)

STAIR NO.3

119

300

100

400

CONFIRME W/DOOR MANUFACTORY

250 300 100

400

EXTERIOR

FRAMED OPENING (SEESTRUCT. DWGS.)

A

7

WT2

WT5a

CJ OFFICE@SF

200

STAIR NO.2

202

STRUCTURAL STEELFRAMING (SEESTRUCT. DWGS.)

CONFIRME W/WINDOW MANUFACTORY

500 206

FIRE STOP SEALANT

STRUCTURALSTEEL FRAMING(SEE STRUCT.DWGS.)

WT8c

415 16

FIRE STOP SEALANT

100

300

230

WT8c

8

G

GENERAL CARGOWAREHOUSE

105

VESTIBULE

112

EXTERIOR

WT3

WT 1

STRUCTURAL STEELFRAMING (REFER TOSTRUCT. DWGS.)

WT8b

159 235 159

OUTLINE O/ HEAVY-DUTY BARRIER RAIL(TYP.)

25 25

197

210

250

WT8a

25

197

460

25

276 276

553

250

407

FIRE STOPSEALANT ATBOTH SIDES

A

STAIR NO.2

118

CARGOJETWAREHOUSE

100

EXTERIOR

50mm DIM.CONCRETE FILLEDMETAL BOLLARDLOCATED ASDIMENSIONED (TYP.)

100

300

FIRE STOP SEALANTAT BOTH SIDES

WT2

300

300

MOTORIZED O/HDRIVE THROUGHDOOR - HORIZONTALLIFT

STRUCTURAL STEELFRAMING (SEESTRUCT. DWGS.)

BENT PLATE SEESTRUCT.DWGS.

400

WT5

CONFIRME W/DOOR MANUFACTORY

354 156

8

E

GENERAL CARGOWAREHOUSE

105

CARGOJETWAREHOUSE

100

WT3

WT3

WT8d

197 169

WT8

266

263

STRUCTURAL STEELFRAMING (SEE STRUCT.DWGS.)

OUTLINE O/ HEAVY-DUTYBARRIER RAIL (TYP.)

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

1 : 10

06/1

1/2

014 1

0:2

8:3

7 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A501

PLAN DETAILS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 10A501

1 PLAN DETAIL AT STAIT NO.1

1 : 10A501

2 PLAN DET. @ CARGOJET DOC./WAREHOUSE

1 : 10A501

3 PLAN DETAIL @ CARGOJET WASHROOMS

1 : 10A501

4 PLAN DETAIL @ FIRE SUPPRESSION RM.

1 : 10A501

13 PLAN DET.@ VEST./GEN. CARGO/CARGOJET

1 : 10A501

8 PLAN DETAIL @ GENERAL CARGO DOCUM.

1 : 10A501

7 PLAN DETAIL @ GEN. CARGO WAREHOUSE

1 : 10A501

10 PLAN DETAIL @ EXIT CORR./ GEN.CARGO

1 : 10A501

11 PLAN DETAIL @ EXIT CORR./ CARGOJET

1 : 10A501

12 PLAN DETAIL @ EXIT CORR./ D.GOODS 1 : 10A501

5 PLAN DETAIL @ CARGOJET WAREHOUSE

1 : 10A501

9 PLAN DETAIL @ GEN. CARGO DOCUM.

1 : 10A501

14 PLAN DETAIL @ STAIR NO.2

1 : 10A501

6 PLAN DETAIL @ VEST./GEN. CARGO W/H

1 : 10A501

15 PLAN DETAIL@STAIR NO.2/CJ WAREHOUSE5

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

11

11

3

3

1 : 10A501

16 PLAN DET.@TENANT DEMISING WALL

305

76

EQ EQ

RAIL

HE

IGH

T

1067

PO

ST H

EIG

HT

1118

254

ATTACH POSTS TO FLOOR USING1/2"x4 1/4" WEDGE ANCHORS, 4 ERPLATE

127 X 127 X 4.7 TH POSTS WITH254 X 254 X12.7 TH BASE PLATES

127 x 127 SECURITY PLASTICTOP CAP

13 GAUGE, RAILSECTION

ATTACH RAIL TO POSTUSING

ROUND PLUGS FOROPEN HOLES

1219 127

254

1473

152

305

305

305

51

178

254 X 254 x12.7 TH. BASE PLATE

HOLS (TYP.)

38

38

254

64

254

1200

300 300

GL

GL

STEEL COLUMN

STEEL FORM CLOSURE 600mm DIA, 6mmTHICK, 1200 mm HIGH, PAINT FINISH

CONCRETE FILL, TOP FTASH WITH STEELCLOSURE

300

CONCRETE SLAB

2

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:3

8 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A502

PLAN & BARRIERRAIL DETAILS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

GUARDRAIL PROFILE

DOUBLE GUARDRAIL ATTACHMENT ELEVATION VIEW

PLAN VIEWENLARGED PLAN VIEW AT COLUMN BASE PLATE

LIFT-OUT DOUBLE RAILASSEMBLY DOUBLE RAIL

1 : 10A502

1 HEAVY-DUTY BARRIER RAIL DETAILS (TYP.) 1 : 20A502

2 STEEL COLUMN PROTECTION

NO. ISSUED DATE

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

UP

UP

UP

25

250mm RUN TYP. 25

SEE S

EC

TIO

N

RIS

ER

S

12.5mm RADIUSTYPICAL

1.25" x 1.25" x 3/8" STEELANGLE SUPPORTSWELDED TO STRINGER PAN& RISERS

12 GA METAL PAN RISER &RUN PANS

CONCRETE ON METAL DECK

STEEL ANGLE &CHANNEL

MC STRINGER

305

(WT9) 2HR. FIRE RATED SHAFTWALL U/S OF STAIR.ADD 3RD. LAYER FIRE RATEDDRYWALL 16mm

12.5mm RADIUSTYPICAL

32x32x3 STEEL ANGLESUPPORTSWELDED TO STRINGERPAN & RISERS

CONCRETE FILLEDPAN

12 GA METAL PAN RISER &RUN PANS

CONCRETE ON METAL DECK

STEEL ANGLE AND CHANNEL

MC STRINGER

25

250mm RUN TYP,

SE

E S

EC

TIO

N

RIS

ER

S

25

305

(WT9) 2HR. FIRE RATED SHAFT WALL U/SOF STAIR.ADD 3RD. LAYER FIRE RATED DRYWALL16mm

51

70

127

MAX13

HANDRAIL TO RETURNINTO WALL AT END

38mm STEEL PIPE HANDRAILWELDED TO STEEL BRACKET

19mm DIA. STEEL BRACKET

76mm DIA. WALL BRACKETSECURED INTO WALLPAINTED FINISH

ANCHOR HANDRAILTO WALL

A

1

STAIR NO.1

102

2

A503

400

184

1270

400 184 1270

4 RUNS @ 255mm

1020 305 1789

102a

102b

610

WALL TO BE SUPPORTEDBY STEEL MISC.STRUCTURE;DESIGNED BY MISC.METALS CONTRACTOR'SENGINEER

WT5

WT5

WT2

WT8

WT8

WT8

WT2

610

4568

(WT9) 2 HR SHAFT WALLU/S OF STAIR TO BEEXTENDED TO THEINTERIOR FACE OF IMPPROVIDE FIRE STOPSEALANT

WALL TO BEEXTENDED UPTO U/S OFROOF

WT5

WALL TO BE EXTENDEDUP TO U/S OF SECONDFLOOR

STEELBRACINGABOVE SEESTRUCT.DWGS

FIRESTOPSEALANT ATBOTHSIDES

FIRE STOPSEALANT

400 76 108 1270 156 3113

A

1

B

A1

2

A503

STAIR NO.1

201

1270

400

184

1270

11 R

UN

S @

255m

m

2805

1160

11 R

UN

S @

255m

m

2805

1776

400

305

610

400 184 1270

*STAIR WALLS TO BESUPPORTED BY STEELMISC. STRUCTURE;DESIGNED BY MISC.METALS CONTRACTOR'SENGINEER

WT8

WT5

WT2

WT2

FIRE STOP SEALANTAT BOTH SIDES

FIRE STOPSEALANT AT BOTHSIDES

STEEL FRAMING SEESTRUCT.DWGS

A

7 1

A503

STAIR NO.2

118

156 1357 1475 156

610

1563 1269

CAGE TO SUPPORTFULLY FRAMED STAIRENCLOSURE. DESIGNEDBY MISC. METALSCONTRACTOR'SENGINEER

WT5

WT5

WT2

WT5a

WT5a

118a

118b

400

1759

2

FIRE STOPSEALANT ATBOTH SIDES

WALL TO BEEXTENDED UP TO U/SOF SECOND FLOOR

FIRE STOPSEALANT ATBOTH SIDES

7

B

A1

1

A503

14 R

UN

S @

25m

m

3570

1160

13R

UN

S @

255m

m

3315

1786202

WT5a

WT5a

5000

300

1430

16

206 1270 155

WT5

WT5a

WT5a

610

*STAIR WALLS TO BESUPPORTED BYSTEEL MISC.STRUCTURE;DESIGNED BY MISC.METALSCONTRACTOR'SENGINEER

2

10

A503

8

1290

3586

16 2250 190 16 1270 156

ONE LAYER OF THEGYP.BOARD TO CLAD THEFACE OF CONC. SALB

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A BA1

OPEN TO CARGOJETWAREHOUSE BEYOND

2750

TYP.

914

(WT9) 2HR. FIRE RATED SHAFTWALL U/S OF STAIR.ADD 3RD. LAYER FIRE RATEDDRYWALL 16mm

WT9

2HR. FIRERATED CEILING

STAIR NO.2

118

CARGOJETWAREHOUSE

100

CAGE TO SUPPORT FULLYFRAMED STAIR ENCLOSURE.DESIGNED BY MISC. METALSCONTRACTOR'S ENGINEER

4200

14 R

ISE

RS

@ 1

83m

m

2559

15 R

ISE

RS

@ 1

83m

m

2741

WT5a

2

1786

2

10

A503

OPEN TOCARGOJET

WAREHOUSEBEYOND

2HR. FIRERATED CEILING

STEEL BEAM. SEESTRUCT. DWGS

2HR. FIRE RATED REQUIRED .REFER TO SHEET A003)

ONE LAYER OF THEGYP.BOARD TOCLAD THE FACE OFCONC. SALB

8

WT5a

8 1730 16

STEEL FRAMING.SEE STRUCT.DWGS.

FIRE STOPSEALANT

FIRE STOPSEALANT

*STORAGE ABOVEIS PROHIBITED

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

A BA1

(WT9) 2HR. FIRE RATEDSHAFT WALL U/S OF STAIR.ADD 3RD. LAYER FIRERATED DRYWALL 16mm

STAIR NO.1

102

STEEL BEAM.SEE STRUCT.DWGS.2 HR. FRRREQUIRED(REFER TOSHEET A003)

12 R

ISE

RS

@ 1

83m

m

2193

12 R

ISE

RS

@ 1

83m

m

2193

5 R

ISE

RS

@ 1

83m

m

914

TYP.

914

4200WT5

WT5

1500

FIRE STOPSEALANT

WT9

CARGOJET DOCUM.

101

STEEL FRAMING. SEESTRUCT. DWGS.

WT8

WT5

STEEL FRAMING.SEE STRUCT.DWGS.

SECOND FLOOR5300

U/S ROOF DECK9500

7

ONE LAYER OF THEGYP.BOARD TOCLAD THE FACE OFCONC. SALB

CJ OFFICE@SF

200

STAIR NO.2

2 HR. FRR CEILING

161270

190

WT5aWT5a

(WT9) 2HR. FIRE RATED SHAFT WALL U/S OFSTAIR.ADD 3RD. LAYER FIRE RATED DRYWALL16mm THICK BELOW STAIR

STEEL STAIR STRUCTURE.

CARGOJETWAREHOUSE

100

CARGOJETWAREHOUSE

100

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:4

2 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A503

STAIR DETAILS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 10A503

7 T/O STEEL STAIR

1 : 10A503

8 B/O STEEL STAIR

1 : 5A503

9 HANDRAIL AT STAIR

1 : 50A503

3 STAIR NO.1 AT GROUND FLOOR

1 : 50A503

4 STAIR NO.1 AT SECOND FLOOR

1 : 50A503

5 STAIR NO.2 AT GROUND FLOOR

1 : 50A503

6 STAIR NO.2 AT SECOND FLOOR

1 : 50A503

1 SECTION1 THROUGH STAIR NO.2

1 : 50A503

2 SECTION THROUGH STAIR NO.1

1 : 50A503

10 SECTION 2 THROUGH STAIR NO.2

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

8

8

GUARD RAIL TO HAVEGALVINIZED FINISH

GUARD RAIL TO BE INSTALLED WHEREGRADE DIFFERENCE IS >600mm- SEE SITE PLAN

48mm DIA PIPE RAILING

13mm x 13mmSTEEL PICKET

48mm DIA STEEL POST@ 4'-0" O/C MAX

TOP OF CONCRETERETAINING WALL

POST SET IN CONCRETERETAINING WALL - REFER TOSTRUCTURAL DWGS

MAX.

203

1067

MAX.

203

MAXIMUM

1219

D

C1

16

STAIR NO.3

119

WT5

WT5

WT8

WT2

WT2

3

A504

UP

119b

119a

WT8

571 1015 550

2000

14 R

UN

S @

255

3570

3300

1700

400

584

1170 183 400

483

(WT9) 2 HR SHAFTWALL U/S OF STAIRTO BE EXTENDEDTO THE INTERIORFACE OF IMPPROVIDE FIRESTOP SEALANT

FIRE STOPSEALANT

WALL TO BE SUPPORTEDBY STEEL MISC.STRUCTURE;DESIGNED BY MISC.METALS CONTRACTOR'SENGINEER

LINE OF SECONDFLOOR SLAB ABOVE

WALL TO BE EXTENDEDUP TO U/S OF SECONDFLOOR

WALL TO BE EXTENDEDUP TO U/S OFROOF

C

C1

16

STAIR NO. 3

211

3

A504

610

1170 183 400

706

270

1160

13 R

UN

S @

255m

m

3315

255

1837

WT5

WT5

WT8 WT2

WT5

*STAIR WALLS TO BESUPPORTED BY STEELMISC. STRUCTURE;DESIGNED BY MISC.METALS CONTRACTOR'SENGINEER

FIRE STOP SEALANT ATBOTH SIDES

FIRE STOP SEALANT ATBOTH SIDES

STEEL BRACINGSEE STRUCT.DWGS.

T/O GROUND FLOOR0

SECOND FLOOR5300

U/S ROOF DECK9500

CD C1

STAIR NO.3

119

GC DOCUM.@GF

109

STAIR NO. 3

211

GC OFFICE 3@SF

207

WT9

WT5

4200

14 R

ISE

RS

@ 1

83m

m

2559

15 R

ISE

RS

@ 1

83m

m

2741

(WT9) 2HR. FIRE RATEDSHAFT WALL U/S OFSTAIR.ADD 3RD. LAYER FIRERATED DRYWALL 16mm

2 HR. FRR REQUIRED(REFER TO SHEET A003)

TYP.

914

WT5

2 HR. FRR REQUIRED(REFER TO SHEET A003)

FIRE STOP SEALANT

FIRE STOPSEALANT

FIRE STOPSEALANT

WT5

WT2

4400 600 5000

50

FIRE STOPSEALANT

FIRE STOPSEALANT

WT8c WT8c

SUSPENDED ACOUSTICCEILING TILE IN T-BARGRID

STEEL BEAM.SEE STRUCT.DWGS

2857

SUSPENDED ACOUSTICCEILING TILE IN T-BARGRID

STEEL BEAM.SEE STRUCT.DWGS

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:4

4 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A504

STAIR DETAILS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 20A504

4 GUARDRAIL DETAIL

1 : 50A504

1 STAIR NO. 3 AT GROUND FLOOR

1 : 50A504

2 STAIR NO. 3 AT SECOND FLOOR

1 : 50A504

3 SECTION THROUGH STAIR NO.3

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

EQ

EQ

SEALANT BOTH SIDESPRECASTCONCRETE REFERTO WALL TYPE

HOLLOW METAL DOOR FRAME. REFER TODOOR SCHEDULE FOR LOCATION OFTHERMALLY BROKEN HOLLOW FRAMES

STEEL STUD AND GYPSUMBOARD WALL

VAR

IES

SEALANT BOTH SIDES

HOLLOW METAL DOOR FRAME. REFER TODOOR SCHEDULE FOR LOCATION OFTHERMALLY BROKEN HOLLOW FRAMES

254

51

152

610

153 152

VISION LITUSE GEORGIANWIRE GLASS INRATED DOORS

DG

FRAME TYPE A

SEE DOOR SCHEDULE

SEE D

OO

R S

CH

ED

ULE

FRAMED OPENING SEESTRUCT.DWGS.

FASTENER (AS REQUIRED)

50

CONFIRM W/DOOR MANUFACTURER

350

SEALANT(AS REQUIRED)

BENT PLATE SEE STRUCT.DWGS.

HIGH SPEED OVERHEAD COILING DOOR

GRID

300

100

SEALANT (AS REQUIRED)

ELECTRICAL MOTORABOVE

WT2

WT2

HIGH SPEEDROLL-UP DOOR

GRID

HSS GIRT. SEESTRUCTURAL DWGS.

100 300

400

CO

NFIR

M W

/DO

OR

MA

NU

FA

CTU

RER

650

EXTERIORCAP TRIM

FIELD CUT JOINTSWHERE REQUIRED

SEALANT (AS REQUIRED)

WT2

O/H SECTIONAL DOOR

GRID

HSS GIRT. SEESTRUCTURAL DWGS.

100 300

400

CO

NFIR

M W

/DO

OR

MA

NU

FA

CTU

RER

VAR

IES

EXTERIOR CAP TRIM

FIELD CUT JOINTSWHERE REQUIRED

SEALANT (AS REQUIRED)

OUTLINE OF O/H DOOR(HORIZONTAL LIFT) IN OPENPOSITION

OUTLINE OF O/H DOOR(VERTICAL LIFT) IN OPEN POSITION

FRAMED OPENING SEE STRUCT.DWGS.

50

CONFIRM W/DOOR MANUFACTURER

50

SEALANT (AS REQUIRED)

BENT PLATE SEESTRUCT.DWGS.

SECTIONALO/H DOOR

GRID

300

100

SEALANT (AS REQUIRED) WT2

EXTERIOR CAP TRIM

SEALANT (AS EQUIRED)

CAULKING AND BACKERROD AROUND DOORFRAME BOTH SIDES

FRAMED OPENING SEESTRUCT.DWGS.

FASTENER (AS REQUIRED)

POP RIVETS

"LOW PROFILE"THROUGH FASTENER

INSULATED THERMALLYBROKEN FRAME

FIELD CUT FEMALE JOINTSWHERE REQUIRED

WT2

INSULATED DOOR

DRIP FLASHINGSEALANT (AS REQUIRED)

FRAMED OPENING SEESTRUCT.DWGS.

FASTENER (AS REQUIRED)

POP RIVETS

100

300

WT2

INSULATED THERMALLYBROKEN FRAME

INSULATED DOOR

CAULKING AND BACKERROD AROUND DOORFRAME BOTH SIDES

GRID

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:4

7 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A601

DOOR SCHEDULE

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 10A601

1 TYPICAL DOOR JAMB DETAILS

DOOR SCHEDULE1

W DOOR LOCATIONDoorType Width Height Door Material

Thickness

FrameMaterial

FrameType

FireRating Hardware Comments

100a CARGOJET WAREHOUSE A 2438 3048 STEEL 45 STEEL - - - MOTORIZED VERTICAL O/H DOCK DOOR W/HYDRAULIC DOCK LEVELER

100b CARGOJET WAREHOUSE A 2438 3048 STEEL 45 STEEL - - MOTORIZED VERTICAL O/H DOCK DOOR W/HYDRAULIC DOCK LEVELER

100c CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100d CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100e CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100f CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100g CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100h CARGOJET WAREHOUSE A1 2438 3048 STEEL 45 STEEL - - MANUAL VERTICAL O/H DOCK DOOR W/SCISSER LIFT (SCISSER LIFT BY TENANT)

100j CARGOJET WAREHOUSE G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

100k CARGOJET WAREHOUSE D 4267 3658 VINYL 51 STEEL - - RAPID-ROLL, DRIVE THROUGH DOOR

100m CARGOJET WAREHOUSE G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

100n CARGOJET WAREHOUSE D 4267 3658 VINYL 51 STEEL - RAPID-ROLL, DRIVE THROUGH DOOR

100p CARGOJET WAREHOUSE B 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - HORIZONTAL LIFT

100q CARGOJET WAREHOUSE B 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - HORIZONTAL LIFT

100r CARGOJET WAREHOUSE B 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - HORIZONTAL LIFT

100s CARGOJET WAREHOUSE B 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - HORIZONTAL LIFT

100t CARGOJET WAREHOUSE D 5486 4877 VINYL 51 STEEL RAPID-ROLL, DRIVE THROUGH DOOR

101a CARGOJET DOCUM. K 915 2128 ALUMINUM/GLASS 45 ALUM. PANIC PROVIDE AUTOMATIC DOOR OPENER / SET IN CURTAIN WALL

101b CARGOJET DOCUM. G 915 2032 HM/GLASS 45 HM A 45 MIN. PANIC

102a STAIR NO.1 G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

102b STAIR NO.1 G 915 2032 HM/GLASS 45 HM A 45 MIN. PANIC -

103 CJ WOMEN'S W.R.@GF F 915 2032 HM 45 HM A - -

104 CJ MEN'S W.R.@GF F 915 2032 HM 45 HM A - -

105a GENERAL CARGO WAREHOUSE C 3658 4267 STEEL 51 STEEL - MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

105b GENERAL CARGO WAREHOUSE C 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

105c GENERAL CARGO WAREHOUSE G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

105d GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL LIFT O/H DOCK DOOR

105e GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL O/H DOCK DOOR

105f GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL O/H DOCK DOOR

105g GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL O/H DOCK DOOR

105h GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL O/H DOCK DOOR

105j GENERAL CARGO WAREHOUSE A 2743 3048 STEEL 45 STEEL - MOTORIZED VERTICAL O/H DOCK DOOR

105k GENERAL CARGO WAREHOUSE D 5486 4877 VINYL 51 STEEL RAPID-ROLL, DRIVE THROUGH DOOR

105m GENERAL CARGO WAREHOUSE C 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

105n GENERAL CARGO WAREHOUSE C 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

105p GENERAL CARGO WAREHOUSE C 4267 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

105q GENERAL CARGO WAREHOUSE G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

105r GENERAL CARGO WAREHOUSE D 4267 3658 VINYL 51 STEEL - RAPID-ROLL DOOR TYPE, DRIVE THROUGH DOOR

105s GENERAL CARGO WAREHOUSE G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

106a COOLER G 914 2134 INS. METAL 45 HM A - PANIC EXTERIOR INSULATED DOOR AND FRAME WITH GEORGIAN WIRE GLASS PANEL

106d COOLER B 3658 3658 STEEL 51 STEEL BY COOLER MANUFACTURER

106e COOLER G 915 2032 INS. METAL 45 HM A INSULATED FREEZER DOOR-INSULATED THERMALLY BROKEN FRAME/BY FREEZERMANUFACTURER

108a GC OFFICE @GF K 915 2128 ALUMINUM/GLASS 45 ALUM. PANIC PROVIDE AUTOMATIC DOOR OPENER / SET IN CURTAIN WALL

108b GC DOCUM. @GF G 915 2032 HM 45 HM A -

109a GC DOCUM. @GF K 914 1954 ALUMINUM/GLASS 45 ALUM. PANIC PROVIDE AUTOMATIC DOOR OPENER / SET IN CURTAIN WALL

109b GENERAL CARGO DOCUM. G 915 2032 HM 45 HM A 45 MIN.

109c GENERAL CARGO DOCUM. G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

110 GC WOMEN'S W.R.@GF F 915 2032 HM 45 HM A -

111 GC MEN'S W.R.@GF F 915 2032 HM 45 HM A -

112a VESTIBULE A 2743 3048 STEEL 45 STEEL - MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

112b VESTIBULE A 2743 3048 STEEL 45 STEEL - MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

112c VESTIBULE C 3658 3658 STEEL 51 STEEL MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

112d VESTIBULE G 915 2032 HM 45 HM A

112e VESTIBULE C 3658 3658 STEEL 51 STEEL 45 MIN. MOTORIZED O/H DRIVE THROUGH DOOR - VERTICAL LIFT, W/ VISION

112f VESTIBULE G 915 2032 HM 45 HM A 45 MIN. PANIC

113 D.GOODS E 1829 2032 HM 45 HM A 45min.

115 FIRE SUPPRESSION F 915 2134 INS. METAL 45 HM A - EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

116a ELECTRICAL ROOM F 915 2134 INS. METAL 45 HM A - EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

116b ELECTRICAL ROOM F 915 2134 INS. METAL 45 HM A - EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

117a EXIT CORRIDOR G 915 2032 HM 45 HM A 45 MIN. PANIC

117b EXIT CORRIDOR G 915 2032 HM 45 HM A 45 MIN. PANIC

117c EXIT CORRIDOR G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

118a STAIR NO.2 G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

118b STAIR NO.2 G 915 2032 HM 45 HM A 45 MIN. PANIC

119a STAIR NO.3 G 915 2032 HM 45 HM A 45 MIN. PANIC

119b STAIR NO.3 G 915 2134 INS. METAL 45 HM A PANIC EXTERIOR INSULATED DOOR AND INSULATED THERMALLY BROKEN FRAME

120 GC MANAGER OFFICE @GR G 915 2032 HM 45 HM A - -

121 CARGOJET VESTIBULE K 915 2128 ALUMINUM/GLASS 45 ALUM. PANIC PROVIDE AUTOMATIC DOOR OPENER / SET IN INTERIOR CURTAIN WALL

122 CJ UNIVERSAL W.R.@GF F 915 2032 HM 45 HM A -

201 STAIR NO.1 G 915 2032 HM 45 HM A 45 MIN. PANIC

202 STAIR NO.2 G 915 2032 HM 45 HM A 45 MIN. PANIC

205 GC OFFICE 1@SF G 915 2032 HM 45 HM A -

206 GC OFFICE 2@SF G 915 2032 HM 45 HM A -

207 GC OFFICE 3@SF G 915 2032 HM 45 HM A -

209 GC WOMEN'S W.R.@SF F 915 2032 HM 45 HM A -

210 GC MEN'S W.R.@SF F 915 2032 HM 45 HM A -

211 STAIR NO.3 G 915 2032 HM 45 HM A 45 MIN. PANIC

212 GC MECH.ROOM F 915 2032 HM 45 HM A 45 MIN.

TYPE A:MOTORIZED VERTICAL LIFT O/H DOCK DOOR,W/ VISION,DOOR NUMBER,HYDRAULICLEVELER,VEHICLE RESTRAIN, HYDRAULICREMOTE POWER RACK,LAMINATEDBUMPER,CONTROL BOX WITH MOUNTINGRACKETS AND DOOR SEALS

DOOR TYPES

TYPE D:HIGH SPEED RAPID-ROLL DRIVE THROUGH DOOR, W/FULLWIDTH VISION PANEL

TYPE B:MOTORIZED O/H DRIVE THROUGH DOOR - HORIZONTAL LIFT, W/ VISION

TYPE F:HM DOOR

TYPE C:MOTORIZED O/H DRIVE THROUGH DOOR - VERTICALLIFT, W/ VISION

TYPE G:HM DOOR

TYPE K:ALUMINUM DOOR

FRAME TYPES

d

TYPE E:HM DOOR

d

FOR TYPE A1:MANUAL VERTICAL LIFT O/H DOCK DOOR,W/ VISION,DOOR NUMBER,VEHICLE RESTRAIN,LAMINATED BUMPER,CONTROL BOX WITH MOUNTINGRACKETS AND DOOR SEALS

*REFER TO A101 FOR HYDRAULIC DOCK LEVELER /SCISSER LIFT LOCATIONS

d

d

d

1 : 5A601

2 RAPID-ROLL DOOR JAMB DETAIL

1 : 15A601

3 RAPID-ROLL DOOR HEAD DETAIL1 : 15A601

5 O/H SECTIONAL DOOR HEAD DETAIL

1 : 5A601

4 O/H SECTIONAL DOOR JAMB DETAIL

3

3

3

3

3

1 : 5A601

6 HOLLOW METAL DOOR HEAD DETAIL 1 : 5A601

7 HOLLOW METAL DOOR JAMB DETAIL

33

1 1

1 1

5 9

3 3

10

NO. ISSUED DATE

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

* PROPOSED CHANGING ORDERNO.1

OCTOBER 07,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

3

3

3

3

3

10

AC. TILE = ACOUSTIC LAY-IN SUSPENDED CEILING TILECONC. = CONCRETEC.T. = CERAMIC TILECPT = CARPETEXP. = EXPOSEDG.W.B. = GYPSUM WALL BOARDI.M.P. = INSULATED METAL PANELP. & PT. = PRIMED & PAINTEDPC. CONC. = PRECAST CONCRETES.G. = STEEL GRATETEXT. = TEXTUREDVCT = VINYL COMPOSITE TILE

* BY COOLER/FREEZER MANUFACTURER

LEGEND:

T/O GROUND FLOOR0

CW1

980965980980980

2153

895

3048

REFER TO DOOR SCHEDULE

51 51 51 51 51

51

51

DG

DG

DG

DG

DG

DG

DG

DGDG

CURTAIN WALL AT NORTH AND SOUTH ELEVATIONAT GENERAL CARGO

4936

51

T/O GROUND FLOOR0

CW2

4936

895

2153

51

51

CURTAIN WALL AT SOUTH ELEVATIONAT CARGOJET

REFER TO DOORSCHEDULE

DG

DG

DG

DG

DG

DG

DG

DGDG

51915519281018795192951929

3

*

51

3048

SECOND FLOOR5300

W2

1158 1158 1158 1158 1158 1158

7000

900

1500

51

51

51 51 51 51 51 51 51

DG DG DG DG DG DG

T/O GROUND FLOOR0

W1

1158 1158 1158

1500

900

51

DG DG DG

3525

SECOND FLOOR5300

DG DG DG DG DG

1106 1158 1158 1158 1210

51 51 51 51 51

900

1500

51

51

W3

GENERAL NOTES

1- FINAL DIMENSION TO BE CONFIRMED ON SITE

2- ALL WINDOWS AND CURTAINWALLS LOCATED ON EXTERIOR WALLS SHALL HAVE INSULATING GLAZING

3- ALL WINDOWS TO BE PREFINISHED ALUMINUMTHERMALLY BROKEN FRAMES WITH SEALED DOUBLEGLAZING

LEGENDDG:DOUBLE GLAZEDSG:SINGLE GLAZEDTPG:TEMPERED GLASS

SEALANT (AS REQUIRED)

PREFINISHED ALUMINUMTHERMALLY BROKEN FRAMESWITH SEALED DOUBLE GLAZING

CAULKING AND BACKER ROD

FRAMED OPENING SEESTRUCT.DWGS.

FASTENER (AS REQUIRED)

WINDOW SILLFLASHING BELOW

POP RIVETSCAP TRIM

100

CO

NFIR

M W

/WIN

DO

W M

AN

UFA

CTU

RE

R

50

127

GRID

300

WT2

EXTERIOR CAPTRIM

SEALANT(AS EQUIRED)

PREFINISHEDALUMINUMTHERMALLYBROKEN FRAMESWITH SEALEDDOUBLE GLAZINGCAULKING AND

BACKER ROD

FRAMED OPENINGSEE STRUCT.DWGS.

FASTENER(AS REQUIRED)

POP RIVETS

"LOW PROFILE"THROUGHFASTENER

DRIP FLASHING

FIELD CUTFEMALE JOINTSWHEREREQUIRED

WT2

FIELD CUT MALEJOINTS WHEREREQUIRED

CAULKING ANDBACKER ROD

EXTERIOR CAPTRIM

"LOW PROFILE"THROUGHFASTENER

POP RIVETS

PREFINISHEDALUMINUMTHERMALLYBROKEN FRAMESWITH SEALEDDOUBLE GLAZING

FRAMED OPENINGSEE STRUCT.DWGS.

SEALANT(AS EQUIRED)

FASTENER(AS REQUIRED)

CAULKING ANDBACKER ROD

WT2

B

CAULKING AND BACKERROD AT BOTH SIDES

POP RIVETS

PREFINISHED CURTAIN WALTHERMALLY BROKEN FRAMEWITH SEALED DOUBLE GLAZING

CAP TRIM

300

100

CW2

FRAMED OPENING SEESTRUCT.DWGS.

FASTENER (AS REQUIRED)

SEALANT (ASREQUIRED)

WT2

CAULKING AND BACKERROD AT BOTH SIDES

40

127

233

CO

NFIR

M W

/ C

UR

TAIN

WALL M

AN

UFA

CTU

RER

SGTPG

SGTPG

SGTPG

SGTPG

SGTPG

3097

INTERIOR CURTAIN WALLAT CARGOJET VESTIBULE

SGTPG

51515151

51 51

51

819

51

2128

3048

CW3

819

51

2128

SGTPG

SGTPG

INTERIOR CURTAIN WALLAT CARGOJET VESTIBULE

SGTPG

CW4

51 516 51 915 51

1583

REFER TO DOORSCHEDULE

*

3048

3

B

PREFINISHED CURTAIN WALLTHERMALLY BROKEN FRAMEWITH SEALED DOUBLE GLAZING

CW2

INTERIOR CURTAIN WALLCW42

33

127

102

101a

CO

NFIR

M W

/ C

UR

TAIN

WALL M

AN

UFA

CTU

RER

CONFIRM W/CURTAINWALL MANUFACTURER

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:5

1 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A602

WINDOW & ROOMFINISH

SCHEDULE

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

ROOM FINISH SCHEDULE

NUMBER DESIGNATION

FLOOR WEST WALL EAST WALL NORTH WALL SOUTH WALL CEILING

CommentsMATERIAL FINISH BASE MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH HEIGHT

100 CARGOJET WAREHOUSE CONC. - - G.W.B/I.M.P. PT. / - G.W.B. PT. I.M.P. - PC. CONC. EXP. - -

101 CARGOJET DOCUM. CONC. - - G.W.B. PT. G.W.B. PT. G.W.B./I.M.P. PT. / - I.M.P. EXP. - - CEILING TO BE COMPLETED BY TENANT

102 STAIR NO.1 CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP. - -

103 CJ WOMEN'S W.R.@GF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

104 CJ MEN'S W.R @GF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

105 GENERAL CARGO WAREHOUSE CONC. - G.W.B. PT. G.W.B./I.M.P. PT. / - I.M.P. - PC. CONC. EXP.

106 COOLER CONC. - * * * * * * * * * * * BY COOLER MANUFACTURER

107 FREEZER CONC. - * * * * * * * * * * * BY FREEZER MANUFACTURER

108 GC OFFICE @GF CONC. CPT CPT G.W.B. PT. I.M.P. - I.M.P. - G.W.B. PT. AC. TILE - 3350

109 GC DOCUM.@GF CONC. C.T. C.T. G.W.B. PT. I.M.P. - G.W.B. PT. I.M.P. AC. TILE - 3350

110 GC WOMEN'S W.R.@GE CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

111 GC MEN'S W.R.@GF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

112 VESTIBULE CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. PC. CONC. EXP.

113 VAULT CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. G.B. 2750 1 HR. FRR CEILING

115 FIRE SUPPRESSION CONC. - I.M.P. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.B. 2750 1 HR. FRR CEILING

116 ELECTRICAL ROOM CONC. - I.M.P. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.B. 2750 1 HR. FRR CEILING

117 EXIT CORRIDOR CONC. - G.W.B. G.W.B. PT. I.M.P. - G.W.B. PT. G.B. 2750 2 HR. FRR CEILING

118 STAIR NO.2 CONC. - G.W.B. PT. G.W.B. PT. I.M.P. - G.W.B. PT. G.B. PT. 2 HR. FRR CEILING

119 STAIR NO.3 CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP. -

120 GC MANAGER OFFICE @GR CONC. CPT CPT G.W.B. PT. I.M.P. - I.M.P. - G.W.B. PT. AC. TILE 3350

121 CARGOJET VESTIBULE CONC. - - INTERIORCURTAINWALL

ALUMINUM/GLASS

G.W.B. PT. INTERIORCURTAINWALL

ALUMINUM/GLASS

EXTERIORCURTAINWALL

ALUMINUM/GLASS

METALACOUSTICTILE

3048

122 CJ UNIVERSAL W.R.@GF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

200 CJ OFFICE@SF CONC. - G.W.B. PT. G.W.B. PT. I.M.P. G.W.B. PT. EXP. CEILING TO BE COMPLETED BY TENANT

201 STAIR NO.1 CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP.

202 STAIR NO.2 CONC. - G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP.

203 CJ WOMEN'S W.R.@SF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

204 CJ MEN'S W.R.@SF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

205 GC OFFICE 1@SF CONC. CPT CPT G.W.B. PT. I.M.P. - I.M.P. - G.W.B. PT. AC. TILE 3000

206 GC OFFICE 2@SF CONC. CPT CPT G.W.B. PT. I.M.P. - G.W.B. PT. G.W.B. PT. AC. TILE 3000

207 GC OFFICE 3@SF CONC. CPT CPT G.W.B. PT. I.M.P. - G.W.B. PT. I.M.P. - AC. TILE 3000

208 GC CORRIDOR@SF CONC. C.T. G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. AC. TILE 3000

209 GC WOMEN'S W.R. @SF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

210 GC MEN'S W.R. @SF CONC. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. G.W.B. C.T. AC. TILE 2750

211 STAIR NO. 3 CONC. G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP.

212 GC MECH.ROOM CONC. G.W.B. PT. G.W.B. PT. G.W.B. PT. G.W.B. PT. EXP.

CURTAIN WALL AND WINDOW SCHEDULE

2

2

2

2

2

2

2

1 : 5A602

1 WINDOW JAMB DETAIL (TYP.) 1 : 5A602

3 WINDOW HEAD DETAIL (TYP.) 1 : 5A602

2 WINDOW SILL DETAIL (TYP.)

1 : 10A602

4 CURTAIN WALL JAMB DETAIL @ CJ VEST.

5

1 : 10A602

5 PLAN DETAIL @ CJ VEST.3

3

1 11

10

10

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

* PROPOSED CHANGING ORDERNO.1

OCTOBER 07,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,20143

FD

FD

FD

FD

FD

FD

FD

15

C

B1

111

110

GC MEN'S W.R.@GF

111

GC WOMEN'SW.R.@GE

110

2

9

73

2

9

873

12 111211

1

DEPRESSSLAP 2"SLOPE TODRAIN

4

124 1860 184

184

640

1629

1588

184

1513

1710

635

184

DEPRESSSLAP 2"SLOPE TODRAIN

905 124 951 25 1646

1050 124 951 25 1646

1

12 111211

WT6

WT7aWT8

WT8

WT4

WT6

WT6

WT7a

WT6WT7a

WT7a

537 2239

2

2

2

2

NOTES:

1. PROVIDE WOOD BLOCKINGFOR ALL TOILETACCESSORIES MOUNTED INGYPSUM BOARD PARTITIONS.

2. MAINTAIN INTEGRITY OF FIRERATING WHERE ACCESSORIESARE IN RATED WALLS.

WASHROOM ACCESSORIES LEGEND

PAPER TOWELDISPENSER/WASTERECEPTACLE WALL

MOUNTED

102

1448

1

GRAB BAR(TOILET SIDE)

SURFACE MOUNTED

MOUNTED ABOVETOILET BOWL & 2" INFRONT OF TOILET

BOWL

2

GRAB BAR(TOILET BACK)

SURFACE MOUNTED

3

MOUNTED 5 7/8"ABOVE TOILET

BOWL

COMBINATION TOILETSEAT COVER, NAPKINDISPOSAL & TOILET

TISSUE

4

SANITARY NAPKINDISPENSER WALL

MOUNTED

5

1137

CU

T-O

UT H

EIG

HT

AD

A R

EC

OM

MEN

DED

1270

CU

T-O

UT H

EIG

HT

AD

A R

EC

OM

MEN

DED

COMBINATION TOILETSEAT COVER & TOILET

TISSUE

6

1137

CU

T-O

UT H

EIG

HT

AD

A R

EC

OM

MEN

DED

SAN. SEAT NAPKINDISPENSER

7

MAX

1067

DUAL TOILET PAPERHOLDER SURFACE

MOUNTED

610

9

COUNTERTOPMOUNTED SOAP

DISPENSER

10

CO

UN

TER

TO

P

MIRROR SURFACEMOUNTED

12

SOAP DISPENSERSURFACE MOUNTED

MAX

1220

11

3' -

3" (M

AX)

TO

TH

E B

OTTO

MO

F R

EFLEC

TIV

ESU

RFAC

E

PAPER TOWELDISPENSER

SURFACE MOUNTED

13

MIN

.

915M

AX.

1220

SAN. NAPKINDISPOSAL SURFACE

MOUNTED

25" TO

30"

8

30

38

51

763

609

153

GRAB BAR (2'-0" LENGTH MIN.)TO BE MOUNTEDHORIZONTALY BEHINDWATER CLOSET

1.2" TO 1.5" MIN. CLEARANCE(30MM TO 40MM)

GRAB BAR 2'-6"(760MM) MIN. LENGTHTO BE MOUNTED AT 30DEGREES TO THEHORIZONTAL

GRAB BAR (2'-0" LENGTH MIN.)TO BE MOUNTEDHORIZONTALY BEHIND WATERCLOSET

30.0

50.0

O.B.C. PERMITEDMOUNTING RANGE 30 TO 50DEGREES

406

MIN. 400MM, MAX 460MM

MIN

. 600M

M

178

MAX. 300MM

MIN

. 750M

M, M

AX. 900

406

MIN

. 400M

M,

MAX

460M

M

877

MIN

. 840 M

M, M

AX.

920

MOUNT GRAB BAR 150MMABOVE WATER TANK, WHENWATER CLOSET HAS A TANK

MIN

. 840 M

M, M

AX.

920

MOUNT GRAB BAR150MM ABOVEWATER TANK, WHENWATER CLOSET HASA TANK

877

152

837

759

MIN. CLEARANCE WIDTH760MM

734

MIN

. C

LE

AR

AN

CE H

EIG

HT A

TFR

ON

T E

DG

E 7

35M

M

279

430

229

203

686

734

205 MM

280 MM

430 MM

MIN

. 230M

M

MIN

. 685M

M

MIN

. 735M

M

LINE OF O.B.C. REQUIREDBARRIER FREE CLEARANCE

MAX

. 840M

M

INSULATE PIPESWHERE THEY PRESENTBURN HAZARD

485

MAX

. 485M

M T

OC

EN

TE

RLIN

E O

FFA

UC

ETS (LEV

ER

TYP

E)

1000

1000M

M M

AX

TO

BO

TTO

M E

DG

E,

UN

LESS

IN

CLIN

ED

460

460 MM MIN. CLEARANCETO A SIDE WALL

1200

1200M

M M

AX

TO

DIS

PE

NS

ING

PO

RTIO

N O

F S

OAP

OR

TO

WEL D

ISPE

NS

ER

LAV NOT TO INTERFERE WITHREQUIRED O.B.C. CLEARANCES

O.B.C. BARRIER FREE WATER CLOSET REQUIREMENTS

O.B.C. BARRIER FREE LAVATORY REQUIREMENTS

PLAN

SECTION ELEVATION

457

MIN. 460MM, MAX480MM

REFER TO INTERIOR DESIGN DRAWINGSIF ANY DISCREPANCIES NOTIFY ARCHITECT IMMEDIATELY.

15

B1

GC WOMEN'S W.R.@SF

209

GC MEN'S W.R. @SF

210

WT6

WT6

WT6

WT6

WT5

WT6

WT6b

838 25 838 25 914

600

2974

184

2903

25

1555

2400

914 184 1542

914 25 1701

1555

25

1394

2

2

2

2

2

2

9

11 11

1

8

9

1

1111

1212

5

555

5

5

5

5

5

9

1212

2

C

B1

C1

1

SK-17b

103

104

CJ WOMEN'SW.R.@GF

103

CJ MEN'S W.R @GF

104

184

6403

184

3579

184

2139

184

WT6a

WT6a

WT6a

WT6a

WT8

WT2

WT6a

WT6a

WT8

WT8

WT8

WT8

WT8

WT8

263

5000

5000

2816

MIN

.

762

WT6a

1225

25

1700

25

762

25

762

25

914

25

914

184

914

25

914

25

1700

184

2139

100 300 2743

108 2751

1700 25 1026

442 1500 25 892 184

457 1959

1000 1417

100 300 142 2417 184

11

12

7

3

8

9 2

1

12

12

11

11

900

8 9

1

5

89

9

9

12

11

12

11

1

CJ UNIVERSALW.R.@GF

122

122

10 100m

INSULATED THERMALLY BROKEN FRAME

INSULATED HM DOOR

1

A304

DO NOT SCALE DRAWINGS. USE ONLY DRAWINGSMARKED "ISSUED FOR CONSTRUCTION". VERIFYCONFIGURATIONS AND DIMENSIONS ON SITE BEFOREBEGINNING WORK. NOTIFY ARCHITECT IMMEDIATELY OFANY ERRORS, OMISSIONS OR DISCREPANCIES.

CHAMBERLAIN ARCHITECT SERVICES LIMITED ANDCHAMBERLAIN CONSTRUCTION SERVICES LIMITED HAVESIMILAR OWNERSHIP.

SEAL

SHEET NAME

START DATE

DRAWN BY

CHECKED BY

SCALE

PROJECT NO.

DRAWING

CONSTRUCTION NORTH TRUE NORTH

Chamberlain ArchitectServices Limited

5096 South Service RoadSuite 103

Burlington, Ontario L7L 5H4

CANADA

Tel: 905.631.7777

Fax: 905.631.7717

www.chamberlainipd.com

ArchitectsConstructors

Managers

As indicated

06/1

1/2

014 1

0:2

8:5

4 A

MC

:\114023\1

14023-A

ir C

arg

o-H

am

ilton- 2014.0

4.3

0_hta

nio

us.rvt

A701

ENLARGEDWASHROOM

PLANS

Checker

Author

114023

Hamilton InternationalAir Cargo Logistics

Facility

Hanger Service Road, HamiltonInternational Airport, Hamilton, ON

April, 2014

1 : 25A701

1 GENERAL CARGO WASHROOMS1 : 25A701

4 PROPOSED SECOND FLOOR WASHROOMS1 : 25A701

2 CARGOGET WASHROOMS AT GROUND FLOOR

8

NO. ISSUED DATE

FOR COORDINATION APRIL 16, 2014

FOR STEEL TENDER JULY 25,2014

FOR CLIENT REVIEW AUGUST 01,2014

FOR ENVELOPE TENDER AUGUST 15,2014

d FOR REVIEW AUGUST 20,2014

0 FOR TENDER AUGUST 22,2014

1 ADDENDUM A01 SEPTEMBER 05

2 ADDENDUM A02 SEPTEMBER 09,2014

3 ADDENDUM A03 SEPTEMBER 23,2014

4 ADDENDUM A04 OCTOBER 02,2014

5 ADDENDUM A05 OCTOBER 02,2014

6 ADDENDUM A06 OCTOBER 03,2014

7 ADDENDUM A07 OCTOBER 08,2014

8 ADDENDUM A08 OCTOBER 09,2014

CCO#1 CHANGING ORDER NO.1 OCTOBER 10,2014

9 ADDENDUM A09 OCTOBER 16,2014

10 ADDENDUM A10 OCTOBER 20,2014

NOC A-1 NOTICE OF CHANGE A-1 OCTOBER 23,2014

NOC A-2 NOTICE OF CHANGE A-2 OCTOBER 29,2014

NOC A-3 NOTICE OF CHANGE A-3 NOVEMBER 05,2014

IFC FOR CONSTRUCTION NOVEMBER 05,2014

CARGOJET WASHROOMS AT SECOND FLOOR BY TENANT