96
, HALTON DISTRICT SCHOOL BOARD SURVEY OF ASBESTOS- CONTAINING MATERIALS MCKENZIE-SMITH BENNETT PUBLIC SCHOOL 69 ACTON BOULEVARD, ACTON, ON Updated February 6, 2020 30038948

Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

,

HALTON DISTRICT SCHOOL BOARD

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL 69 ACTON BOULEVARD, ACTON, ON

Updated February 6, 2020

30038948

Page 2: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com i

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC

SCHOOL

69 Acton Boulevard, Acton, ON

Prepared for:

Halton District School Board

J.W. Singleton Education Center

2050 Guelph Line, P.O. Box 2005

Burlington, ON L7R 3Z2

Attention: Wayne Hartwell

Prepared by:

Arcadis Canada Inc.

121 Granton Drive, Suite 12

Richmond Hill, Ontario L4B 3N4

Tel 905 764 9380

Our Ref.:

30038948

Date:

February 6, 2020

This document is intended only for the use of

the individual or entity for which it was

prepared and may contain information that is

privileged, confidential and exempt from

disclosure under applicable law. Any

dissemination, distribution or copying of this

document is strictly prohibited.

Shubham Shrinig, B.Eng., E.I.T.

Environmental Specialist

Ada Nguyen, B.Sc., CIH

Project Manager, Industrial Hygienist

Page 3: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com ii

CONTENTS

1 INTRODUCTION ................................................................................................................................ 1-1

2 METHODOLOGY ............................................................................................................................... 2-1

2.1 Survey ........................................................................................................................................ 2-1

2.2 Assessment ................................................................................................................................ 2-1

3 SURVEY RESULTS ........................................................................................................................... 3-1

4 DISCUSSION ..................................................................................................................................... 4-1

5 USE AND LIMITATIONS OF THIS REPORT .................................................................................... 5-1

TABLES

Table 1.1 Bulk Material Samples (from O.Reg. 278/05) .................................................................. 1-2

Table 3.1 Summary of Laboratory Analyses of Bulk Samples ......................................................... 3-2

Table 3.2 Summary of Asbestos-Containing Materials .................................................................3-16

APPENDICES

Appendix A Floor Plans

Appendix B Laboratory Reports

Appendix C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to

the Regulation Respecting Asbestos on Construction Projects and in Buildings

and Repair Operations

Page 4: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

1-1

1 INTRODUCTION

Arcadis Canada Inc. (Arcadis) was retained by the Halton District School Board to provide an updated

survey of the locations of asbestos-containing materials at McKenzie-Smith Bennett Public School located

at 69 Acton Boulevard in Acton, Ontario following asbestos remediation associated with the renovation

project between July to August 2019.

Asbestos has been widely used in buildings, both in friable applications (materials which can be easily

crumbled such as pipe and tank insulation, sprayed-on fireproofing and acoustic and texture coat

applications) and in non-friable materials such as floor tile, fire-rated ceiling tile, gaskets, cement board,

cement pipe, drywall joint compound and so on. Plaster applications (walls, ceilings, bulkheads, etc.) may

also contain asbestos. The use of asbestos in friable applications was curtailed in Ontario around the

mid-1970s. Most buildings constructed prior to about the mid-1970s contain some form of friable

asbestos-containing material. The use of asbestos in certain non-friable products continued beyond the

1970s. A sample list of suspect asbestos containing building materials is provided in Appendix C.

Control of exposure to asbestos is governed in Ontario by Regulation 278/05 - Designated Substance -

Asbestos on Construction Projects and in Buildings and Repair Operations. Disposal of asbestos waste

(friable and non-friable materials) is governed by Ontario Regulation 278/05 and by Ontario Regulation 347,

Waste Management - General.

The major requirements of O.Reg. 278/05 with respect to asbestos surveys and assessments are as

follows:

Survey Records:

• non-friable asbestos-containing materials (e.g., vinyl floor tiles, ceiling tiles, drywall joint

compound, plaster, etc.) are to be included in asbestos survey records effective

1 November 2007;

• asbestos survey records are to be updated:

(a) at least once in every 12-month period;

(b) whenever the owner becomes aware of new information; and

• asbestos-containing materials are to be inspected at reasonable intervals in order to

determine their condition.

Bulk Samples:

• the minimum number of bulk samples to be collected from an area of homogeneous

material is set out in Table 1 of the regulation (Table 1 is reproduced below).

• if analysis establishes that a bulk material sample contains 0.5 per cent or more asbestos

by dry weight:

(a) it is not necessary to analyze other bulk material samples taken from the same

area of homogeneous material; and

(b) the entire area of homogeneous material from which the bulk materials sample

was taken is deemed to be asbestos-containing material.

Page 5: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

1-2

Table 1.1: Bulk Material Samples (from O.Reg. 278/05)

Item Type of Material Size of Area of

Homogeneous Material

Minimum Number of Bulk

Material Samples to be

Collected

1.

Surfacing material, including without limitation material that is applied to surfaces by spraying, by trowelling or otherwise, such as acoustical plaster on ceilings and fireproofing materials on structural members

Less than 90 square metres 3

90 or more square metres, but less than 450 square

metres 5

450 or more square metres 7

2. Thermal insulation, except as described in Item 3

Any size 3

3. Thermal insulation patch Less than 2 linear metres or

0.5 square metres 1

4. Other material Any size 3

In practice, application of the Table 1 requirements means that the specified minimum number of negative

(i.e., less than 0.5% asbestos) bulk sample analysis results will be required in order to classify a material

as non asbestos.

Section 10 of O.Reg. 278/05 – Owner’s Responsibility before requesting tender or arranging work – requires

that an owner shall have an investigation carried out in order to determine if materials, that are likely to be

handled, dealt with, disturbed or removed during the alteration of a building, are asbestos-containing and,

if so, whether the asbestos-containing material is friable or non-friable and to identify the type of asbestos

in the material. Section 10 also requires that the owner shall have a report prepared detailing the

investigation findings which is to be provided to any prospective constructor.

Corrective Actions

If asbestos containing fireproofing or acoustical or thermal insulation has fallen and is being disturbed so

that exposure to the material is likely to occur, O.Reg. 278/05 requires that the owner shall cause the fallen

material to be cleaned up and, if it is readily apparent that material will continue to fall because of the

deterioration, the owner shall repair, seal, remove or permanently enclose the material.

O.Reg. 278/05 classifies the asbestos work operations into three types (Type 1, 2 and 3) and specifies

procedures to be followed in conducting asbestos abatement work.

Page 6: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

2-1

2 METHODOLOGY

2.1 Survey

Site inspections were carried out by Arcadis staff on July 12 to July 14, 2011 to determine the locations of

building construction materials suspected of containing asbestos. All readily accessible areas, including

spaces above accessible suspended ceilings, were inspected throughout the facility. Site inspections were

also performed in November 2012, April 2016, May 2018 and June 2018.

Additional site inspections were performed in select areas of the building in April 2019 as part of a building

renovation project. This report has been updated to include information from additional investigations in

2019 and subsequent remediation that took place in 2019.

Representative bulk samples of material from different ages of construction were collected by Arcadis staff

during the course of the site inspection and were forwarded to EMSL Canada Inc. for analysis of asbestos

content. Determination of the locations of asbestos-containing materials were made based on results of

bulk sample analysis, and on visual observations and physical characteristics of the applications at each

inspection location.

2.2 Assessment

During the survey, the condition of all friable materials is assessed. Assessment involves the evaluation of

a number of factors, including:

• asbestos content;

• physical damage;

• water damage;

• accessibility;

• adjacent activity, vibrations;

• air distribution system (air plenum); and

• friability.

Recommendations for appropriate corrective measures are based on findings of the assessment and

consist primarily of either repair or removal (and replacement) of the asbestos containing materials. No

recommended corrective actions were required at the time that this report was prepared.

Page 7: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-1

3 SURVEY RESULTS

Arcadis reviewed reports prepared by Arcadis for the Halton District School Board entitled Survey of

Asbestos-Containing Materials, McKenzie-Smith Bennett Public School, 69 Acton Boulevard, Acton,

Ontario dated December 29, 2018 and Pre-Renovation Designated Substances and Hazardous Materials

Survey, McKenzie-Smith Bennett Public School, 69 Acton Boulevard, Acton, Ontario dated April 11, 2019.

Information and bulk sample analysis results obtained from these reports were utilized by Arcadis in the

preparation of this report.

On the basis of the survey work carried out, we report that friable asbestos-containing materials are present

in McKenzie-Smith Bennett Public School in the following accessible applications:

• thermal insulation applied to pipe straights, fittings, breeching and hot water tank in the

Boiler Room (20C);

• thermal insulation applied to pipe fittings and ducts in the Upper Mechanical Room (205A);

and

• thermal insulation applied to pipe fittings and sections of pipe straights at various locations

throughout the building.

Asbestos-containing thermal insulation applied to pipe fittings observed throughout the facility is a grey-

coloured cementitious-like material.

Asbestos-containing thermal insulation applied to pipe straights is “Air-cell” or “Anti-sweat”. “Air-cell” is a

trade name for a grey-coloured corrugated paper-like type of pipe insulation, usually found on heating and

domestic hot water piping. “Anti-sweat” insulation is a layered paper-like material, typically brown in colour

that may contain intermittent layers of black tar-like paper and/or intermittent layers of a white paper-like

material, usually found on domestic cold water lines and sanitary and rain water piping.

Glass fibre insulation is readily visually distinguishable (typically yellow in colour) from asbestos containing

insulation materials and was, therefore, not tested for asbestos content.

All thermal insulation, with the exception of glass fibre material, should be assumed to contain asbestos

unless a bulk sample analysis indicates otherwise.

Visual inspections and laboratory analyses of representative bulk samples of materials confirm that non-

friable asbestos-containing materials are present in the following accessible applications:

• vinyl floor tiles (12” x 12”) in various locations throughout the facility;

• vinyl floor tiles (9” x 9”) in various locations throughout the facility;

• drywall joint compound applied to drywall walls in the basement and in various locations

throughout the 1968 era of construction of the building;

• textured plaster on the lower portion of walls in various locations throughout the 1953 era

of construction of the building;

• textured plaster on exterior overhangs of windows and exits;

Page 8: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-2

• cement panels on exterior bulkhead at exits 26 and 28 and exterior fascia of the north end

of the building;

• cement panels in Room 29 (scoreboard wall), and closet ceilings of corridor 48;

• block filler paint on concrete block walls in the 1955 era of construction of the building;

• cement counter tops in Rooms 125 and 206A;

• cement pipes (assumed asbestos) in various locations throughout the building; and

• caulking between pre-cast concrete roof deck panels in the 1956 era of construction of the

building.

A room-by-room summary of the locations and conditions of asbestos-containing materials identified is

presented in Table 3.2. The locations of accessible asbestos containing materials are identified on the floor

plans provided in Appendix A.

A summary of the results of laboratory analysis of bulk samples is presented in Table 3.1. The laboratory

reports are provided in Appendix B.

Table 3.1: Summary of Laboratory Analyses of Bulk Samples

McKenzie-Smith Bennett Public School

Sample No Location Description Asbestos Content

1A Room 29G Mortar bed on 1” x 1” white ceramic tile, 1953 <0.25% chrysotile (Pt. Ct.) (1,4)

1B Room 29G Mortar bed on 1” x 1” white ceramic tile, 1953 <0.25% chrysotile (Pt. Ct.) (1,4)

1C Room 29G Mortar bed on 1” x 1” white ceramic tile, 1953 <0.25% chrysotile (Pt. Ct.) (1,4)

2A Room 29G Grout on 1” x 1” white ceramic tile, 1953 None detected (1)

2B Room 29G Grout on 1” x 1” white ceramic tile, 1953 None detected (1)

2C Room 29G Grout on 1” x 1” white ceramic tile, 1953 None detected (1)

3A Room 29G Caulking at urinal – white, 1953 None detected (PLM) (1) None detected (TEM) (1)

3B Room 29G Caulking at urinal – white, 1953 None detected (1)

3C Room 29G Caulking at urinal – white, 1953 None detected (1)

4A Room 29G Heavy textured block filler paint, 1953 None detected (1)

4B Room 29G Heavy textured block filler paint, 1953 None detected (1)

4C Room 29G Heavy textured block filler paint, 1953 None detected (1)

Page 9: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-3

Sample No Location Description Asbestos Content

5A Room 29E Mortar bed on 1” x 1” brown ceramic tile,1958 None detected (1)

5B Room 29E Mortar bed on 1” x 1” brown ceramic tile,1958 None detected (1)

5C Room 29E Mortar bed on 1” x 1” brown ceramic tile,1958 None detected (1)

6A Room 29E Grout on 1” x 1” brown ceramic tile, 1958 None detected (1)

6B Room 29E Grout on 1” x 1” brown ceramic tile, 1958 None detected (1)

6C Room 29E Grout on 1” x 1” brown ceramic tile, 1958 None detected (1)

7A Room 29F Grout around urinal, 1958 None detected (1)

7B Room 29F Grout around urinal, 1958 None detected (1)

7C Room 29F Grout around urinal, 1958 None detected (1)

8A Room 29G Caulking at door, 1953 None detected (PLM) (1) None detected (TEM) (1)

8B Room 29G Caulking at door, 1953 None detected (1)

8C Room 29G Caulking at door, 1953 None detected (1)

9A Room 27K Plaster rough coat, 1964 None detected (1)

9B Room 27K Plaster rough coat, 1964 None detected (1)

9C Room 27K Plaster rough coat, 1964 None detected (1)

10A Room 29 Concrete block mortar, 1958 None detected (1)

1A Room 29E Concrete block filler paint, 1958 <0.43% chrysotile (1,4)

1B Room 29E Concrete block filler paint, 1958 <0.42% chrysotile (1,4)

1C Room 29F Concrete block filler paint, 1958 <0.46% chrysotile (1,4)

2A Room 29E Textured plaster ceiling, topcoat, white, 1958 <0.25% chrysotile (Pt. Ct.) (1,4)

2B Room 29E Textured plaster ceiling, top coat, white, 1958 0.25% chrysotile (Pt. Ct.) (1,4)

2C Room 29F Textured plaster ceiling, top coat, white, 1958 <0.25% chrysotile (Pt. Ct.) (1,4)

2D Room 29F Textured plaster ceiling, top coat, white, 1958 <0.25% chrysotile (Pt. Ct.) (1,4)

3A Room 29E Textured plaster ceiling, base coat, grey, 1958 None detected (1)

3B Room 29E Textured plaster ceiling, base coat, grey, 1958 None detected (1)

3C Room 29F Textured plaster ceiling, base coat, grey, 1958 None detected (1)

Page 10: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-4

Sample No Location Description Asbestos Content

3D Room 29F Textured plaster ceiling, base coat, grey, 1958 None detected (1)

4A Room 29E Concrete block mortar, 1958 None detected (1)

4B Room 29F Concrete block mortar, 1958 None detected (1)

4C Room 29F Concrete block mortar, 1958 None detected (1)

5A Room 114 Smooth plaster, top coat, white, 1958 None detected (1)

5B Room 113 Smooth plaster, top coat, white, 1958 None detected (1)

5C Room 113 Smooth plaster, top coat, white, 1958 None detected (1)

5D Room 114 Smooth plaster, top coat, white, 1958 None detected (1)

5E Cor 46 Smooth plaster, top coat, white, 1958 None detected (1)

5F Cor 46 Smooth plaster, top coat, white, 1958 None detected (1)

6A Room 114 Smooth plaster, base coat, grey, 1958 None detected (1)

6B Room 113 Smooth plaster, base coat, grey, 1958 None detected (1)

6C Room 113 Smooth plaster, base coat, grey, 1958 None detected (1)

6D Room 114 Smooth plaster, base coat, grey, 1958 None detected (1)

6E Cor 46 Smooth plaster, base coat, grey, 1958 None detected (1)

6F Cor 46 Smooth plaster, base coat, grey, 1958 None detected (1)

7A Cor 46 Textured plaster lower wall, top coat, white,

1958 None detected (1)

7B Cor 46 Textured plaster lower wall, top coat, white,

1958 None detected (1)

7C Cor 46 Textured plaster lower wall, top coat, white,

1958 None detected (1)

8A Cor 46 Textured plaster upper wall, base coat, 1958 None detected (1)

8B Cor 46 Textured plaster upper wall, base coat, 1958 None detected (1)

8C Cor 46 Textured plaster upper wall, base coat, 1958 None detected (1)

9A Room 105 Drywall joint compound, 1956 None detected (1)

9B Room 105 Drywall joint compound, 1956 None detected (1)

9C Room 5B Drywall joint compound, 1956 None detected (1)

Page 11: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-5

Sample No Location Description Asbestos Content

10A Room 115 Smooth plaster wall, topcoat, white,1955 None detected (1)

10B Room 116 Smooth plaster wall, topcoat, white,1955 None detected (1)

11A Room 115 Smooth plaster wall, base coat, grey,1955 None detected (1)

11B Room 116 Smooth plaster wall, base coat, grey,1955 None detected (1)

1A Room 115 Sprayed fireproofing None detected (2)

1B Room 115 Sprayed fireproofing None detected (2)

1C Room 115 Sprayed fireproofing None detected (2)

2A Corridor 50 2’x4’ ceiling tile – fissure with random pinhole None detected (2)

2B Corridor 57 2’x4’ ceiling tile – fissure with random pinhole None detected (2)

2C Room 121 2’x4’ ceiling tile – fissure with random pinhole None detected (2)

1A Ext. wall

Room 201 Rough lines pattern brick, mortar - Grey None detected (2)

1B Ext. wall

Room 202 Rough lines pattern brick, mortar - Grey None detected (2)

1C Ext. wall

Room 203 Rough lines pattern brick, mortar - Grey None detected (2)

2A Room 6B Concrete block mortar None detected (2)

2B Room 6B Concrete block mortar None detected (2)

2C Room 6A Concrete block mortar None detected (2)

3A Room 202 Concrete block mortar None detected (2)

3B Room 201 Concrete block mortar None detected (2)

3C Room 203 Concrete block mortar None detected (2)

4A Corridor 53B Smooth plaster – Top coat and rough coat None detected (2)

4B Corridor 53B Smooth plaster – Top coat and rough coat None detected (2)

4C Corridor 53A Smooth plaster – Top coat and rough coat None detected (2)

5A Room 15A Concrete block mortar None detected (2)

5B Room 15A Concrete block mortar None detected (2)

5C Room 15A Concrete block mortar None detected (2)

Page 12: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-6

Sample No Location Description Asbestos Content

6A Ext. wall

room 20A Rippled pattern brick, mortar – Dark grey None detected (2)

6A Ext. wall

Room 20A Rippled pattern brick, mortar – Dark grey None detected (2)

6C Ext. wall

Room 20C Rippled pattern brick, mortar – Dark grey None detected (2)

7A Interior brick

Exit 26 Smooth brick mortar - Grey None detected (2)

7B Interior brick

Exit 26 Smooth brick mortar - Grey None detected (2)

7C Interior brick

Exit 26 Smooth brick mortar - Grey None detected (2)

8A Room 6A Caulking between siporex roof decking - Grey 3% Chrysotile (2)

9A Room 6A Urinal caulking - White None detected (2)

9B Room 6A Urinal caulking - White None detected (2)

9C Room 6A Urinal caulking - White None detected (2)

10A Exit 6/ Corr.

53B Exterior/Interior door caulking – Grey, tacky 3% Chrysotile (2,3)

11A Room 20A Exterior door caulking – Light brown None detected (2)

11B Room 20A Exterior door caulking – Light brown None detected (2)

11C Room 20A Exterior door caulking – Light brown None detected (2)

12A Room 20C Exterior door caulking – White, soft None detected (2)

12B Room 20C Exterior door caulking – White, soft None detected (2)

12C Room 20C Exterior door caulking – White, soft None detected (2)

13A Corridor

42/43 Interior door caulking – White, hard None detected (2)

13B Corridor

42/43 Interior door caulking – White, hard None detected (2)

13C Corridor

42/43 Interior door caulking – White, hard None detected (2)

14A Room 15A Concrete block filler paint 2% Chrysotile (2)

15A Room 6B Concrete block filler paint None detected (2)

Page 13: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-7

Sample No Location Description Asbestos Content

15B Room 6B Concrete block filler paint None detected (2)

15C Room 6A Concrete block filler paint None detected (2)

16A Room 15B Black mastic under (9” x 9”) asbestos-

containing vinyl floor tile 4% Chrysotile (2)

17A Room 115 12” x 12“ Vinyl floor tile – Blue with white and

dark blue streaks None detected (TEM)(2)

17B Room 115 12” x 12“ Vinyl floor tile – Blue with white and

dark blue streaks None detected (2)

17C Room 115 12” x 12“ Vinyl floor tile – Blue with white and

dark blue streaks None detected (2)

18A Room 115 Black mastic under assumed non-asbestos

vinyl floor tile 5% Chrysotile (2,3)

19A Room 115 3” Light grey vinyl baseboard None detected (TEM) (2)

19B Room 115 3” Light grey vinyl baseboard None detected (2)

19C Room 115 3” Light grey vinyl baseboard None detected (2)

20A Room 115 3” Light grey vinyl baseboard adhesive –

Crème None detected (2)

20B Room 115 3” Light grey vinyl baseboard adhesive –

Crème None detected (2)

20C Room 115 3” Light grey vinyl baseboard adhesive –

Crème None detected (2)

21A Room 6A 6” x 6” White ceramic wall tile grout - White None detected (2)

21B Room 6A 6” x 6” White ceramic wall tile grout - White None detected (2)

21C Room 6A 6” x 6” White ceramic wall tile grout - White None detected (2)

22A Room 6A 6” x 6” White ceramic wall tile adhesive -

Beige None detected (2)

22B Room 6A 6” x 6” White ceramic wall tile adhesive -

Beige None detected (2)

22C Room 6A 6” x 6” White ceramic wall tile adhesive -

Beige None detected (2)

23A Room 15A 12” x 12” Ceiling tile - Uniform hole pattern None detected (2)

23B Room 15A 12” x 12” Ceiling tile - Uniform hole pattern None detected (2)

23C Room 15B 12” x 12” Ceiling tile - Uniform hole pattern None detected (2)

Page 14: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-8

Sample No Location Description Asbestos Content

24A Room 115 2’ x 4’ Ceiling tile – Wide random fissure and

pinhole None detected (2)

24B Room 115 2’ x 4’ Ceiling tile – Wide random fissure and

pinhole None detected (2)

24C Room 115 2’ x 4’ Ceiling tile – Wide random fissure and

pinhole None detected (2)

25A Room 102 2’ x 4’ Ceiling tile – Rough texture and pinhole None detected (2)

25B Room 101 2’ x 4’ Ceiling tile – Rough texture and pinhole None detected (2)

25C Room 103 2’ x 4’ Ceiling tile – Rough texture and pinhole None detected (2)

26A Corridor 41 2’ x 4’ Ceiling tile – Small fissure and pinhole,

brown backing None detected (2)

26B Corridor 41 2’ x 4’ Ceiling tile – Small fissure and pinhole,

brown backing None detected (2)

26C Corridor 42 2’ x 4’ Ceiling tile – Small fissure and pinhole,

brown backing None detected (2)

27A Room 5A 2’ x 4’ Ceiling tile – Wide fissure on 2’ and

pinhole None detected (2)

27B Room 5A 2’ x 4’ Ceiling tile – Wide fissure on 2’ and

pinhole None detected (2)

27C Room 5A 2’ x 4’ Ceiling tile – Wide fissure on 2’ and

pinhole None detected (2)

28A Room 28A 2’ x 4’ Ceiling tile – Random thin fissure and

pinhole None detected (2)

28B Room 28A 2’ x 4’ Ceiling tile – Random thin fissure and

pinhole None detected (2)

28C Room 28A 2’ x 4’ Ceiling tile – Random thin fissure and

pinhole None detected (2)

29A Room 28I 2’ x 4’ Ceiling tile – Large hole and pinhole None detected (2)

29B Room 28I 2’ x 4’ Ceiling tile – Large hole and pinhole None detected (2)

29C Room 28I 2’ x 4’ Ceiling tile – Large hole and pinhole None detected (2)

1A Room 207 2’ x 4’ ceiling tile – fissure on the 4’ None detected (2)

1B Room 207A 2’ x 4’ ceiling tile – fissure on the 4’ None detected (2)

1C Room 209 2’ x 4’ ceiling tile – fissure on the 4’ None detected (2)

Page 15: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-9

Sample No Location Description Asbestos Content

2A Room 207A interior brick mortar None detected (PLM) (2)

None detected (TEM) (2)

2B Corr. 59 interior brick mortar None detected (2)

2C Room 207A interior brick mortar None detected (2)

3A Room 201 concrete block mortar None detected (PLM) (2)

None detected (TEM) (2)

3B Room 203A concrete block mortar None detected (2)

3C Room 204 concrete block mortar None detected (2)

4A Room 205A cyporex None detected (2)

4B Room 205A cyporex None detected (2)

4B Room 205A cyporex None detected (2)

5A Room 206 1’ x 1’ ceiling tile mastic – brown coloured None detected (PLM) (2)

None detected (TEM) (2)

5A Room 206A 1’ x 1’ ceiling tile mastic – brown coloured None detected (2)

5A Room 206 1’ x 1’ ceiling tile mastic – brown coloured None detected (2)

48A Roof A Roof A – roof membrane None detected (PLM) (2)

None detected (TEM) (2)

48B Roof A Roof A – roof membrane None detected (2)

48C Roof A Roof A – roof membrane None detected (2)

49A Roof A Roof A - kraft vapor barrier None detected (PLM) (2)

None detected (TEM) (2)

49B Roof A Roof A - kraft vapor barrier None detected (2)

49C Roof A Roof A - kraft vapor barrier None detected (2)

50A Roof B Roof B – roof membrane None detected (PLM) (2)

None detected (TEM) (2)

50B Roof B Roof B – roof membrane None detected (2)

50C Roof B Roof B – roof membrane None detected (2)

51A Roof B Roof B – asphalt vapor barrier None detected (PLM) (2)

None detected (TEM) (2)

51B Roof B Roof B – asphalt vapor barrier None detected (2)

Page 16: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-10

Sample No Location Description Asbestos Content

51C Roof B Roof B – asphalt vapor barrier None detected (2)

1A-VFT-1 Room 102 9” vinyl floor tile – clay with white streaks 4.9% Chrysotile (2)

3A-VFT-3 Room 104 9” vinyl floor tile – med grey with dark grey

and white streak 6.3% Chrysotile (2)

5A-VFT-5A Room 5A 12” vinyl floor tile – dark green with light green

smudges

None detected (PLM) (2)

None detected (TEM) (2)

5B-VFT-5A Room 5A 12” vinyl floor tile – dark green with light green

smudges None detected (2)

5C-VFT-5 Room 105 12” vinyl floor tile – dark green with light green

smudges None detected (2)

6A-VFT-5A Room 5A 12” vinyl floor tile – light green with green and

white feathery smudges

None detected (PLM) (2)

None detected (TEM) (2)

6B-VFT-44C Room 44C 12” vinyl floor tile – light green with green and

white feathery smudges None detected (2)

6C-VFT-40D Room 40D 12” vinyl floor tile – light green with green and

white feathery smudges None detected (2)

8A-VFT-9 Room 109 9” vinyl floor tile – brown with white streaks 5.5% Chrysotile (2)

9A-VFT-28 Room 28 12” vinyl floor tile – cream with white and

brown streak

<0.25% Chrysotile (PLM) (2,4)

<0.25% Chrysotile (TEM) (2,4)

9B-VFT-28A Room 28A 12” vinyl floor tile – cream with white and

brown streak 0.8% Chrysotile (2)

10A-VSF-28C Room 28C Vinyl sheet flooring – tan with sparkles None detected (PLM) (2)

None detected (TEM) (2)

10B-VSF-28C Room 28C Vinyl sheet flooring – tan with sparkles None detected (2)

10C-VSF-28C Room 28C Vinyl sheet flooring – tan with sparkles None detected (2)

21A-VFT-15A Room 15A 9” vinyl floor tile – white with black streak 6% Chrysotile (2)

23A-VFT-16 Room 116 12” vinyl floor tile – white with thin brown

streaks

None detected (PLM) (2)

None detected (TEM) (2)

23B-VFT-18B Room 18B 12” vinyl floor tile – white with thin brown

streaks None detected (2)

23C-VFT-22C Room 22C 12” vinyl floor tile – white with thin brown

streaks 5.5% Chrysotile (2)

Page 17: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-11

Sample No Location Description Asbestos Content

34A-VSF-18C Room 18C Vinyl sheet flooring – white with teal None detected (PLM) (2)

None detected (TEM) (2)

34B-VSF-18C Room 18C Vinyl sheet flooring – white with teal None detected (2)

34C-VSF-18C Room 18C Vinyl sheet flooring – white with teal None detected (2)

38A-VFT-20B Room 20B 12” vinyl floor tile – white with black/grey

streaks

None detected (PLM) (2)

None detected (TEM) (2)

38B-VFT-27A Room 27A 12” vinyl floor tile – white with black/grey

streaks 3.6% Chrysotile (2)

41A-VSF-27K Room 27K Vinyl sheet flooring (stone pattern) None detected (PLM) (2)

None detected (TEM) (2)

41B-VSF-27K Room 27K Vinyl sheet flooring (stone pattern) None detected (2)

41C-VSF-27K Room 27K Vinyl sheet flooring (stone pattern) None detected (2)

42A-VFT-206A Room 206A 9” vinyl floor tile – salmon with white and black

streak 5.6% Chrysotile (2)

11A-TH-43 Room 43 Thermal insulation “Anti-sweat” on pipe

straight None detected (2)

11B-TH-204 Room 204 Thermal insulation “Anti-sweat” on pipe

straight None detected (2)

11C-TH-54 Room 54 Thermal insulation “Anti-sweat” on pipe

straight None detected (2)

11D-TH-29H Room 29H Thermal insulation “Anti-sweat” on pipe

straight 10% Chrysotile (2)

26-TH-49 Room 49 Thermal insulation “Aircell” on pipe straight 40% Chrysotile (2)

44-TH-27H Room 27H Insulation on pipe valve None detected (2)

45-TH-44C Room 44C Pipe fitting insulation (debris) 35% Chrysotile (2)

29A-TH-29F Room 29F Textured plaster None detected (2)

29B-TH-exit 6 Exit 6 Textured plaster 2.3% Chrysotile (2)

28A-JC-49 Room 49 Drywall joint compound None detected (2)

28B-JC-40 Room 40 Drywall joint compound None detected (2)

28C-JC-40D Room 40D Drywall joint compound 1.2% Chrysotile (2)

17A-PL-46 Room 46 Plaster smooth None detected (2)

Page 18: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-12

Sample No Location Description Asbestos Content

17B-PL-59 Room 59 Plaster smooth None detected (2)

17C-PL-50 Room 50 Plaster smooth None detected (2)

17D-PL-17A Room 17A Plaster smooth None detected (2)

17E-PL-50 Room 50 Plaster smooth None detected (2)

17F-PL-21 Room 121 Plaster smooth None detected (2)

17G-PL-53 Room 53 Plaster smooth None detected (2)

18A-PL-46 Room 46 Plaster textured None detected (2)

18B-PL-46 Room 46 Plaster textured None detected (2)

18C-PL-50 Room 50 Plaster textured None detected (2)

18D-PL-49 Room 49 Plaster textured (1953) 2.6% Chrysotile (2)

27A-PL-49 Room 49 Plaster smooth on circular column None detected (2)

27B-PL-49 Room 49 Plaster smooth on circular column None detected (2)

27C-PL-49 Room 49 Plaster smooth on circular column None detected (2)

46A-CT-24 Room 124 2x4 ceiling tile – long deep wide fissure None detected (2)

46B-CT-27 Room 127 2x4 ceiling tile – long deep wide fissure None detected (2)

46C-CT-26 Room 126 2x4 ceiling tile – long deep wide fissure None detected (2)

16A-CT-46 Room 46 2x4 ceiling tile – chicken scratch None detected (2)

16B-CT-50 Room 50 2x4 ceiling tile – chicken scratch None detected (2)

16C-CT-48 Room 48 2x4 ceiling tile – chicken scratch None detected (2)

15A-TH-EXIT30 Exit 30 Textured plaster 2.6% Chrysotile (2)

39-CT-20 Room 120 12x12 ceiling tile – deep long fissure with

pinhole (1st layer) None detected (2)

40- CT -20 Room 120 12x12 ceiling tile – (2nd layer) None detected (2)

30-TH-EXIT1 Exit 1 Remnant 12”x12” ceiling tile None detected (2)

31-th-exit1

Mastic Exit 1 Remnant mastic on 12”x12” ceiling tile

None detected (PLM) (2)

None detected (TEM) (2)

46A-CT-206 Room 206 12x12 ceiling tile – no pattern None detected (2)

46B-CT-206 Room 206 12x12 ceiling tile – no pattern None detected (2)

Page 19: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-13

Sample No Location Description Asbestos Content

46C-CT-206 Room 206 12x12 ceiling tile – no pattern None detected (2)

2A-JC-3 Room 3 Drywall joint compound (1956 era) None detected (2)

2B-JC-2 Room 2 Drywall joint compound (1956 era) None detected (2)

2C-JC-28H Room 28H (basement)

Drywall joint compound (1968 era) 1.9% Chrysotile (2)

41-CT-7A Area 41 12” x 12” ceiling tile – deep directional fissure 1% Chrysotile (2,3)

28D-CT-1A Room 28D 2’ x 4’ ceiling tile – circular pattern red back 3% Amosite (2,3)

43-CT-2A Room 43 2’ x 4’ ceiling tile – circular pattern white back 2% Chrysotile (2,3)

43-TH-206A Room 206A Cement board table top 23.8% Chrysotile (2)

41-TH-10A Area 41 Cement panel on main entrance foyer

bulkhead 9% Chrysotile (2)

075A-PLTX1A Stair 075A Textured plaster on exterior soffit 4.1% Chrysotile (2)

9 Area 6C Boiler breeching insulation 15% Chrysotile (2)

10 Area 6C Domestic cold water pipe fitting insulation 19% Chrysotile (2)

11 Area 6C Hot water heating pipe fitting insulation 80% Chrysotile (2)

12 Area 6C Domestic hot water pipe fitting insulation 21% Chrysotile (2)

13 Area 34B Duct insulation 67% Chrysotile (2)

1-A Room 104 Mastic under 9” x 9” asbestos-containing vinyl

floor tile – black colour 6.6% Chrysotile (2,3)

2-A Room 104 Mastic under vinyl baseboard – dark brown

colour None detected (TEM) (2,3)

2-B Room 102 Mastic under vinyl baseboard – dark brown

colour None detected (2)

2-C Room 101 Mastic under vinyl baseboard – dark brown

colour None detected (2)

3-A Room 104 Cellulose fibre board behind radiator inside

radiator cabinet None detected (2)

3-B Room 102 Cellulose fibre board behind radiator inside

radiator cabinet None detected (2)

3-C Room 104 Cellulose fibre 12” x 12” acoustic wall tile None detected (2)

4-A Room 104 Cement parging on concrete block wall behind

radiator None detected (TEM) (2)

Page 20: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-14

Sample No Location Description Asbestos Content

4-B Room 104 Cement parging on concrete block wall behind

radiator None detected (2)

4-C Room 102 Cement parging on concrete block wall behind

radiator None detected (2)

5-A Room 104 Caulking on interior window frame – grey

colour None detected (TEM) (2)

5-B Room 102 Caulking on interior window frame – grey

colour None detected (2)

5-C Room 101 Caulking on interior window frame – grey

colour None detected (2)

6-A Room 104 Caulking between pre-cast concrete roof deck

panels – grey colour 2.6% Anthophyllite (2)

7-A Room 104 Mastic behind 12” x 12” acoustic wall tiles –

dark brown colour None detected (TEM) (2,3)

7-B Room 102 Mastic behind 12” x 12” acoustic wall tiles –

dark brown colour None detected (2)

7-C Room 101 Mastic behind 12” x 12” acoustic wall tiles –

dark brown colour None detected (2)

8-A Room 104 Caulking on exterior window frames – grey

colour None detected (TEM) (2)

8-B Room 001 Caulking on exterior window frames – grey

colour None detected (2)

8-C Room 101 Caulking on exterior window frames – grey

colour None detected (2)

9-A Room 104 Vinyl baseboard – rigid - black colour None detected (TEM) (2,3)

9-B Room 104 Vinyl baseboard – rigid - black colour None detected (2,3)

9-C Room 101 Vinyl baseboard – rigid - black colour None detected (2,3)

10-A Room 102 Vinyl sheet flooring – beige colour None detected (TEM) (2,3)

10-B Room 102 Vinyl sheet flooring – beige colour None detected (2,3)

10-C Room 2

(001) Vinyl sheet flooring – beige colour None detected (2,3)

11-A Room 3A

(002) Vinyl baseboard – pliable – black colour None detected (TEM) (2,3)

11-B Room 3C

(002) Vinyl baseboard – pliable – black colour None detected (2,3)

Page 21: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-15

Sample No Location Description Asbestos Content

11-C Room 3D

(004) Vinyl baseboard – pliable – black colour None detected (2,3)

NOTES:

(1) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Pre-Renovation Designated Substances and Hazardous Materials Survey, McKenzie-Smith Bennett Public School, 69 Acton Boulevard, Acton, Ontario dated April 11, 2019.

(2) Sample results derived from a report prepared by Arcadis for the Halton District School Board entitled Survey of Asbestos Containing Materials, McKenzie-Smith Bennett Public School, 69 Acton Boulevard, Acton, Ontario dated December 29, 2018.

(3) Asbestos-containing materials collected in this area have since been removed. Results provided here are for reference purposes only.

(4) “Asbestos-containing material” is defined as material that contains 0.5% or more asbestos by dry weight.

< = Less than.

Chrysotile = Chrysotile asbestos.

Amosite = Amosite asbestos.

Anthophyllite = Anthophyllite asbestos.

Page 22: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-16

Table 3.2: Summary of Asbestos-Containing Materials

McKenzie-Smith Bennett Public School

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 101 Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 101A Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 102 Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 102A Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 103 Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 104 Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 104A Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 105 Drywall joint compound 1.9% Chrysotile In closet >10 m2 Non-Friable G

Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 5A Drywall joint compound 1.9% Chrysotile East wall >10 m2 Non-Friable G

Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

Page 23: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-17

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 5B Drywall joint compound 1.9% Chrysotile North wall 10-50 m2 Non-Friable G

Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 5C Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 6A Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G NACMO

1 6B Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G NACMO

1 6C Pipe fitting insulation 19% Chrysotile Below ceiling 20-30 fittings Friable G

Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 6D NACMO

1 107

NACMO.

Vinyl floor tile (12” x 12”) not sampled due to post-2000 installation date.

1 108 Vinyl floor tile (9” x 9”) 4.9% Chrysotile All flooring 60 m2 Non-Friable G

1 8A NACMO

1 109 Vinyl floor tile (9” x 9”) 5.5% Chrysotile All flooring 60 m2 Non-Friable G

Page 24: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-18

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 110 Drywall joint compound 1.9% Chrysotile Bulkhead <10 m2 Non-Friable G

Vinyl floor tile (9” x 9”) 4.9% Chrysotile All flooring 60 m2 Non-Friable G

1 111 Vinyl floor tile (9” x 9”) 4.9% Chrysotile All flooring 60 m2 Non-Friable G

1 112 Drywall joint compound 1.9% Chrysotile Bulkhead <10 m2 Non-Friable G

Vinyl floor tile (9” x 9”) 5.5% Chrysotile All flooring 60 m2 Non-Friable G

1 113 NACMO

1 114 Pipe fitting insulation 19% Chrysotile Above ceiling N/A Friable G Limited access above ceiling.

Pipe straight insulation 10% Chrysotile Above ceiling N/A Friable G

1 115 Pipe fitting insulation 19% Chrysotile Above ceiling N/A Friable G Limited access above ceiling.

Pipe straight insulation 10% Chrysotile Above ceiling N/A Friable G

Concrete block paint 2% Chrysotile On exterior walls 10-50 m2 Non-Friable G

1 15A Pipe fitting insulation 19% Chrysotile Below ceiling 2 fittings Friable G

Vinyl floor tile (9” x 9”) 6% Chrysotile All flooring 10-50 m2 Non-Friable G

Concrete block paint 2% Chrysotile On walls 10-50 m2 Non-Friable G

1 116 Vinyl floor tile (12” x 12”) 5.5% Chrysotile All flooring 60 m2 Non-Friable G

Concrete block paint 2% Chrysotile On exterior walls 10-50 m2 Non-Friable G

1 117 Concrete block paint 2% Chrysotile On exterior walls 10-50 m2 Non-Friable G

Page 25: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-19

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 17A Vinyl floor tile (9” x 9”) 6% Chrysotile All flooring 10-50 m2 Non-Friable G

Concrete block paint 2% Chrysotile On exterior walls 10-50 m2 Non-Friable G

1 118 NACMO

1 18A No access to vault at time of survey.

1 18B Vinyl floor tile (12” x 12”) 5.5% Chrysotile All flooring 40 m2 Non-Friable G

1 18C NACMO

1 18D NACMO

1 119 NACMO

1 120 NACMO

1 20A NACMO

1 20B Pipe fitting insulation 19% Chrysotile Above ceiling < 5 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

1 20C Pipe fitting insulation 19% Chrysotile Below ceiling 20-30 fittings Friable G

Boiler breeching

insulation 15% Chrysotile Breeching 10-20 m2 Friable G

Tank insulation 15% Chrysotile Hot water tank <5 m2 Friable G

1 121 NACMO

1 21A Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Friable G

Page 26: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-20

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 21B Pipe fitting insulation 19% Chrysotile Above ceiling <5 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

1 122 NACMO

1 22A NACMO

1 22B NACMO

11 22C Vinyl floor tile (12” x 12”) 5.5% Chrysotile All flooring 10-20 m2 Non-Friable G

1 22D NACMO

1 123 NACMO

1 124 Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Friable G

1 24A Pipe fitting insulation 19% Chrysotile Below ceiling 1 fitting Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring <1 m2 Non-Friable G

1 125 Pipe fitting insulation 19% Chrysotile Above ceiling <5 fittings Friable G

Cement board 23.8 Chrysotile Countertop <5 m2 Non-Friable G

1 126 Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Friable G

1 26A Pipe fitting insulation 19% Chrysotile Below ceiling 1 fitting Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring <1 m2 Non-Friable G

1 127 Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Friable G

1 27A NACMO

Page 27: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-21

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 27B No access at time

of survey.

1 27C Pipe fitting insulation 19% Chrysotile Below ceiling <5 fittings Friable G

1 27D Textured plaster 2.3% Chrysotile Shower area 20 m2 Non-friable G

1 27D1 NACMO

1 27E NACMO

1 27F NACMO

1 27G NACMO

1 27H Pipe fitting insulation 19% Chrysotile Below ceiling 5-10 fittings Friable G

1 27H1 NACMO

1 27J Pipe fitting insulation 19% Chrysotile Above ceiling 10-20 fittings Friable G

1 27K NACMO

1 27L NACMO

1 27M Pipe fitting insulation 19% Chrysotile Below ceiling 10-20 fittings Friable G

1 28 Pipe fitting insulation 19% Chrysotile Below ceiling 5 fittings Friable G

Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring >100 m2 Non-Friable G

Page 28: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-22

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 28A Pipe straight insulation

(Anti-sweat) 10% Chrysotile Above ceiling 5 m Friable G

Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring 10-50 m2 Non-Friable G

Cement pipe Assumed asbestos Below ceiling 5 m Non-Friable G

1 28B NACMO

1 28C NACMO

1 28D NACMO

1 28E Pipe fitting insulation 19% Chrysotile Below ceiling <5 fittings Friable G

Drywall joint compound 1.9% Chrysotile Bulkhead <10 m2 Non-Friable G

Vinyl floor tile (12” x 12”) 0.8% Chrysotile Entrance to stage <10 m2 Non-Friable G

1 28F Ceiling tile (2’ x 4’) 2% Chrysotile All ceiling <5 m2 Non-Friable G

Vinyl floor tile (12” x 12”) 0.8% Chrysotile Office flooring <5 m2 Non-Friable G

1 28G NACMO

1 28H Pipe fitting insulation 19% Chrysotile Below ceiling 4 fittings Friable G

Drywall joint compound 1.9% Chrysotile Bulkhead <10 m2 Non-Friable G

Ceiling tile (2’ x 4’) 2% Chrysotile All ceiling 10-50 m2 Non-Friable G

Vinyl floor tile (12” x 12”) 0.8% Chrysotile Base of stairs to basement <10 m2 Non-Friable G

1 29 Cement board 9% Chrysotile Behind scoreboard 10-50 m2 Non-Friable G

Pipe fitting insulation 19% Chrysotile Below ceiling 4 fittings Friable G

Page 29: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-23

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 29A Pipe fitting insulation 19% Chrysotile Below ceiling 10-20 fittings Friable G

1 29B NACMO

1 29C Pipe fitting insulation 19% Chrysotile Below ceiling 10-20 fittings Friable G

1 29D Pipe fitting insulation 19% Chrysotile Below ceiling 10-20 fittings Friable G

1 29E NACMO

1 29F Pipe fitting insulation 19% Chrysotile Wall cabinet 5-10 fittings Friable G

1 29G NAMCO

1 29H NAMCO

1 29J Pipe fitting insulation 19% Chrysotile Above ceiling 10-20 fittings Friable G

Textured plaster 2.3% Chrysotile Above ceiling 10-50 m2 Non-friable G

1 29K NACMO

1 127 Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Friable G

1 30A Pipe fitting insulation 19% Chrysotile Above and below ceiling 2 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring <1 m2 Non-Friable G

1 40 NACMO

1 40A NACMO

1 40B NACMO

1 40C NACMO

Page 30: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-24

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 40D NACMO

1 40E NACMO

1 40F NACMO

1 41

NACMO - Drywall ceiling in the north

vestibule was installed in 2011.

1 41A Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 41B Caulking 2.6% Anthophyllite Between pre-cast concrete

roof deck panels <1 m2 Non-Friable G

1 42 NACMO

1 43 Pipe straight insulation 10% Chrysotile Above ceiling <5 m Friable G

Drywall joint compound 1.9% Chrysotile Above library door <10 m2 Non-Friable G

1 44 NACMO

1 44A Pipe fitting insulation 19% Chrysotile Beneath cupboard 5-10 fittings Friable G

Drywall joint compound 1.9% Chrysotile 75% of walls 10-50 m2 Non-Friable G

1 44B Drywall joint compound 1.9% Chrysotile South wall 10-50 m2 Non-Friable G

1 44C Pipe fitting insulation

(debris) 45% Chrysotile Inside wall near toilet 10-50 m2 Friable P

Drywall joint compound 1.9% Chrysotile 75% of walls 10-50 m2 Non-Friable G

Page 31: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-25

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 45 NACMO

1 46 Pipe fitting insulation 19% Chrysotile Above ceiling 20-30 fittings Friable G

Textured plaster 2.6% Chrysotile Lower portion of walls 50-100 m2 Non-Friable G

1 47 Pipe fitting insulation 19% Chrysotile Crawlspace under stair

and above ceiling 20-30 fittings Friable G

1 48 Pipe fitting insulation 19% Chrysotile Above ceiling 5-10 fittings Non-Friable G

Textured plaster 2.6% Chrysotile Lower portion of walls 10-20 m2 Non-Friable G

Cement board 9% Chrysotile Ceiling of closets 5-10 m2 Non-Friable G

1 49 Pipe fitting insulation 19% Chrysotile Above ceiling near main

office <5 fittings Friable G

Pipe straight insulation

(Aircell) 40% Chrysotile

Above ceiling near main office

2 m Friable G

Textured plaster 2.6% Chrysotile Lower portion of walls 50-100 m2 Non-Friable G

1 49A NACMO

1 50 Pipe fitting insulation 19% Chrysotile Above ceiling 10-15 fittings Friable G

Textured plaster 2.6% Chrysotile Lower portion of walls 50-100 m2 Non-Friable G

1 51 Pipe fitting insulation 19% Chrysotile Above ceiling 10-15 fittings Friable G

1 52 Pipe fitting insulation 19% Chrysotile Above ceiling <5 fittings Friable G Limited access above ceiling.

1 53 Pipe fitting insulation 19% Chrysotile Above ceiling 10-15 fittings Friable G

Page 32: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-26

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 53A NACMO

1 53B NACMO

1 Exit 1 & Foyer

NACMO

1 Exit 2 Textured plaster 2.3% Chrysotile All ceiling of interior foyer

and exterior soffit 10-20 m2 Non-Friable G

1 Exit 3 Textured plaster 2.3% Chrysotile Exterior soffit <10 m2 Non-Friable G

1 Exit 5 Cement board 9% Chrysotile Exterior soffit <10 m2 Non-Friable G

Textured plaster 2.3% Chrysotile Exterior soffit <10 m2 Non-Friable G

1 Exit 6 Cement board 9% Chrysotile Exterior soffit <10 m2 Non-Friable G

Textured plaster 2.3% Chrysotile Exterior soffit <10 m2 Non-Friable G

1 Exit 17 NACMO

1 Exit 22 Textured plaster 2.3% Chrysotile Exterior soffit <10 m2 Non-Friable G

1 Exit 26 Cement board 9% Chrysotile Exterior soffit <10 m2 Non-Friable G

1 Exit 28 Cement board 9% Chrysotile Interior wall above door and exterior bulkhead

<10 m2 Non-Friable G

1 Exit

29/30 Drywall joint compound 1.9% Chrysotile Interior bulkhead <10 m2 Non-Friable G

Cement board 9% Chrysotile Exterior soffit <10 m2 Non-Friable G

Textured plaster 2.3% Chrysotile Exterior soffit <10 m2 Non-Friable G

Page 33: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-27

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

1 Exterior Cement board 9% Chrysotile Fascia on North end >100 m2 Non-Friable G

Textured plaster 2.3% Chrysotile Window overhang of

Rooms 21B, 22B, 23, 24, 25, 26, and 27D

10-50 m2 Non-Friable G

2 32A Pipe straight insulation

(Anti-sweat) 10% Chrysotile Above ceiling <5 m Friable G

Cement pipe Assumed asbestos Above ceiling <5 m Non-Friable G

2 32B Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring <10 m2 Non-Friable G

2 32C NACMO

2 35A Pipe fitting insulation 19% Chrysotile Below ceiling 5-10 fittings Friable G

2 54 Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring 10-50 m2 Non-Friable G

2 55 Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring 10-50 m2 Non-Friable G

2 57 Textured plaster 2.6% Chrysotile Lower portion of walls 50-100 m2 Non-Friable G

2 58 Pipe fitting insulation 19% Chrysotile Above ceiling 1 fitting Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile 2nd floor landing <10 m2 Non-Friable G

2 59 NACMO

2 59A NACMO

2 201 Pipe fitting insulation 19% Chrysotile Below sink 5 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 50 m2 Non-Friable G

Page 34: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-28

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

2 201A Pipe fitting insulation 19% Chrysotile Below sink 4 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 20 m2 Non-Friable G

2 202 Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring 50 m2 Non-Friable G

2 203 Pipe fitting insulation 19% Chrysotile Below sink 2 fittings Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 50 m2 Non-Friable G

2 204 Pipe straight insulation

(Anti-sweat) 10% Chrysotile Above ceiling <5 m Friable G

Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

2 205 Vinyl floor tile (12” x 12”) 0.8% Chrysotile All flooring 50 m2 Non-Friable G

2 205A Pipe fitting insulation 19% Chrysotile Below ceiling 5-10 fittings Friable G

Mechanical insulation 67% Chrysotile Air handling Duct 5-10 m2 Friable G

2 206 NACMO

2 206A Pipe fitting insulation 19% Chrysotile Below ceiling 3 fittings Friable G

Cement board 23.8% Chrysotile Countertop <5 m2 Non-Friable P

Vinyl floor tile (9” x 9”) 5.6% Chrysotile All flooring 60 m2 Non-Friable G

2 207 Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

2 207A Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

2 208 Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

2 209 Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

Page 35: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

3-29

LEVEL ROOM MATERIAL ASBESTOS

CONTENT

LOCATION

WITHIN SPACE

ESTIMATED

QUANTITY

FRIABLE OR

NON-FRIABLE CONDITION COMMENTS

2 210 Vinyl floor tile (12” x 12”) 3.6% Chrysotile All flooring 30 m2 Non-Friable G

NOTES: Condition: G = Good. F = Fair. P = Poor. NACMO: No Asbestos-Containing Materials Observed.

NOTE!: Asbestos may also be present in locations that are presently inaccessible (e.g., in pipe chases, behind walls, above suspended gypsum board or plaster ceilings, and below carpets).

Page 36: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

4-1

4 DISCUSSION

The owner of a building is required to provide information on the locations of asbestos containing material

to:

i) any person who is an “occupier”(1) of the building. The occupier is then responsible for

providing the information to their own employees;

ii) any prospective constructors, contractors and subcontractors prior to requesting tenders

or arranging for the demolition, alteration or repair of all or part of a building. The

information to be provided shall identify whether any material that is likely to be handled,

dealt with, disturbed or removed is asbestos-containing material; describe the condition of

the material; state whether the material is friable or non-friable; and contain drawings, plans

and specifications, as appropriate, to show the locations of material;

iii) any employer with whom the owner arranges or contracts for work not described in ii) above

that may involve asbestos-containing material or is to be carried out in close proximity to

and may disturb the material;

iv) owner’s staff, if they perform work that involves asbestos-containing material or work that

is to be carried out in close proximity to and may disturb the material.

If material suspected of containing asbestos which is not identified in the asbestos survey records is

discovered during the course of any work in a facility, then either the constructor or the owner is required

to immediately notify (orally and in writing):

a) an inspector at the office of the Ministry of Labour nearest the workplace;

b) the owner;

c) the contractor; and

d) the joint health and safety committee or the health and safety representative.

The owner is also responsible for providing tenderers with a list of designated substances (including

asbestos) at the tendering stage of a project.

This report was prepared as part of the asbestos management program, not for the purposes of construction

or renovation projects. Additional investigation and testing may be required prior to construction or

renovation projects.

Bulk sampling of building materials was carried out in accordance with the minimum sampling requirements

specified in Table 1 of O.Reg. 278/05. We recommend that additional samples of certain types of material

which may have been mixed on site at the time of construction (plaster, drywall joint compound, ceiling

(1) An “occupier” is defined as: (a) a person who is in physical possession of premises, or (b) a person who has responsibility for and control over the condition of premises or the activities carried on there, or

control over persons allowed to enter the premises.

Page 37: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

4-2

texture coat, etc.) be tested for asbestos content prior to the disturbance of these materials at the time of

renovations, alterations or demolition work.

Asbestos may also be present in materials which were not sampled during the course of the asbestos

survey carried out by Arcadis, including, but not limited to, roofing materials, fire doors, mastics or

cementitious levelling compound under vinyl flooring, acoustic ceiling tile adhesive, grout, caulking, gaskets

in piping, internal components of boilers, paints and coatings, components of electrical equipment, (e.g. –

electrical wiring insulation, non-metallic sheathed cable, electrical panel partitions, arc chutes, high-grade

electrical paper, etc.), concrete, etc., and/or in locations that are presently inaccessible (e.g., in pipe chases,

behind walls, above suspended gypsum board or plaster ceilings, and below carpets). Asbestos may also

be present in the form of vermiculite insulation in cavities in concrete or cement block walls (used as in-fill

insulation). Confirmatory testing of any such materials could be undertaken as the need arises (i.e., at the

time of renovations, modifications or demolition) or the materials can be assumed to contain asbestos

based on findings in adjacent areas.

As noted above, if any materials which may contain asbestos and which were not tested during the course

of the asbestos survey are discovered during any construction activities, the work shall not proceed until

such time as the required notifications have been made and an appropriate course of action is determined.

Page 38: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

SURVEY OF ASBESTOS-CONTAINING MATERIALS

MCKENZIE-SMITH BENNETT PUBLIC SCHOOL

arcadis.com

5-1

5 USE AND LIMITATIONS OF THIS REPORT

This report, prepared for the Halton District School Board, does not provide certification or warranty,

expressed or implied, that the investigation conducted by Arcadis identified all asbestos-containing

materials present in the subject facilities. The work undertaken by Arcadis was directed to provide

information on the presence of asbestos-containing building materials based on visual inspection of readily

accessible areas of the building and on the results of laboratory analysis of bulk samples of material

gathered in the course of the visual inspection. The survey did not include for identification of asbestos in

process materials, equipment (including electrical equipment and wiring), furniture (e.g., chairs, table tops,

chalkboards, etc.), nor material outside of the building (e.g. asphaltic pavement).

This report was prepared by Arcadis for the Halton District School Board. Any use which a third party makes

of the report, or reliance on, or decisions to be based on it, is the responsibility of such third parties.

Page 39: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

APPENDIX A Floor Plans

Page 40: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

CP

Pf

CP

FTFT

FT

FT

PL

FT

JC

CP

JC

P*

Pf

P*FT

Pf

FT

Pf

*

Pf*

FT

FT

P*

P*

Pf

Pf*

Pf*

Pf

PL

FT

PL

PL

CP,

PL

JCP*

JC,CT

Pf

FT,

Pf

FT

Pf

Pf*

EQ

Pf*

FT

Pf*

Pf*

PL

Pf*

Pf*

Pf*FT

Pf*

Pf*

CP,

PL

FT

FT

Pf*

JC

CP

FT

JC

FT

JC

Pf

Pf

Pf*

Pf

Pf

PL

Pf*PL

CB

Pf*

PL

PL

Pf

PL

Pf

Pf

*

Pf

P*

Pf

PL

PL

PL

PL

CLKCLK

CLK

CLK

CLK

CLK

CLK

CP

Pf, FT

CP, PL

Pf, FT

Pf

CLK

CLK

BF

CT

BF

BF

BF

BFBF

Pf

BF

P*

P*

FT

FT

FT

PFEQ

FTPf,CP

FT ,Pf*

FT

FT

FT

FT FT

Pf

FT

FT

Pf

Pf

Pf

FT

FT

P*, CP

FT

FT

PL

P*

FT

DEC. 2019

AS SHOWN

G.E.C. A.T.N.

Drawn By:

Date:

Scale:

Approved By:

Drawing No:

Project No:

HALTON DISTRICT SCHOOL BOARD

LOCATIONS OF ASBESTOS-CONTAINING

MATERIALS

McKENZIE-SMITH BENNETT PUBLIC SCHOOL

69 ACTON BOULEVARD, ACTON, ON

FIRST AND SECOND FLOOR PLAN

30038948-1

LEGEND:

203 FUNCTIONAL SPACE

THROUGHOUT FUNCTIONAL SPACE

* ABOVE CEILING ASSEMBLY

P ASBESTOS ON STRAIGHT SECTIONS OF PIPING

AND PIPE FITTINGS (FRIABLE)

Pf ASBESTOS ON PIPE FITTINGS (FRIABLE)

EQ ASBESTOS ON MECHANICAL EQUIPMENT (FRIABLE)

CT ASBESTOS CEILING TILE (NON-FRIABLE)

FT ASBESTOS VINYL FLOOR TILE (NON-FRIABLE)

PL ASBESTOS PLASTER (NON-FRIABLE)

JT ASBESTOS DRYWALL JOINT COMPOUND (NON-FRIABLE)

CP ASBESTOS CEMENT PRODUCT (NON-FRIABLE)

CLK ASBESTOS CAULKING (NON - FRIABLE)

)

BF BLOCK FILLER PAINT (NON - FRIABLE)

NOTE:

1. INTERIORS OF ALL FIRE DOORS ARE

ASSUMED TO CONTAIN ASBESTOS.

30038948

Page 41: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 42: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 43: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 44: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

APPENDIX B Laboratory Reports

Page 45: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551806010

702170-167

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS Bennett PS/702170-167

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 5/24/2018

Analyzed: 5/31/2018

Amit Kaul

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00011A

Room 115 - Sprayed Fireproofing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/30/2018 65% 35%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00021B

Room 115 - Sprayed Fireproofing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/30/2018 70% 30%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00031C

Room 115 - Sprayed Fireproofing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/31/2018 65% 35%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00042A

Corridor 50 - 2'x4' ceiling tile - fissure with random pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/30/2018 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00052B

Corridor 57 - 2'x4' ceiling tile - fissure with random pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/30/2018 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551806010-00062C

Room 121 - 2'x4' ceiling tile - fissure with random pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/31/2018 80% 20%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 12:35PM Page 1 of 2

Page 46: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551806010

702170-167

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

PLM (2)Anne Balayboa

PLM (4)Michelle Lung

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 05/31/201812:35:17

Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 12:35PM Page 2 of 2

Page 47: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS BENNETT/702170-120

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/26/2017

Analyzed: 4/29/2017

Sean Parliament

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00011A

Ext. wall Room 201/Rough lines pattern brick, mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00021B

Ext. wall Room 202/Rough lines pattern brick, mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00031C

Ext. wall Room 203/Rough lines pattern brick, mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00042A

Room 6B/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00052B

Room 6B/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00062C

Room 6A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00073A

Room 202/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 1 of 12

Page 48: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00083B

Room 201/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00093C

Room 203/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00104A-Skim Coat

Corridor 53B/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-0010A4A-Rough Coat

Corridor 53B/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00114B-Skim Coat

Corridor 53B/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-0011A4B-Rough Coat

Corridor 53B/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00124C-Skim Coat

Corridor 53A/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-0012A4C-Rough Coat

Corridor 53A/Smooth plaster – Top coat and rough coat

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 2 of 12

Page 49: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00135A

Room 15A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00145B

Room 15A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00155C

Room 15A/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00166A

Ext. wall room 20A/Rippled pattern brick, mortar – Dark grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00176A

Ext. wall Room 20A/Rippled pattern brick, mortar – Dark grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00186C

Ext. wall Room 20C/Rippled pattern brick, mortar – Dark grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00197A

Interior brick Exit 26/Smooth brick mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00207B

Interior brick Exit 26/Smooth brick mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 3 of 12

Page 50: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00217C

Interior brick Exit 26/Smooth brick mortar - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00228A

Room 6A/Caulking between siporex roof decking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 97% 3% ChrysotilePLM Gray

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00238B

Room 6A/Caulking between siporex roof decking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00248C

Room 6B/Caulking between siporex roof decking - Grey

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00259A

Room 6A/Urinal caulking - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00269B

Room 6A/Urinal caulking - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-00279C

Room 6A/Urinal caulking - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-002810A

Exit 6/ Corr. 53B/Exterior/Interior door caulking – Grey, tacky

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 97% 3% ChrysotilePLM Gray/Blue

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 4 of 12

Page 51: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-002910B

Exit 6/ Corr. 53B/Exterior/Interior door caulking – Grey, tacky

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003010C

Exit 5/ Corr. 53A/Exterior/Interior door caulking – Grey, tacky

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003111A

Room 20A/Exterior door caulking – Light brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003211B

Room 20A/Exterior door caulking – Light brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003311C

Room 20A/Exterior door caulking – Light brown

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003412A

Room 20C/Exterior door caulking – White, soft

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003512B

Room 20C/Exterior door caulking – White, soft

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003612C

Room 20C/Exterior door caulking – White, soft

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 5 of 12

Page 52: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003713A

Corridor 42/43/Interior door caulking – White, hard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003813B

Corridor 42/43/Interior door caulking – White, hard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-003913C

Corridor 42/43/Interior door caulking – White, hard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004014A

Room 15A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 98% 2% ChrysotilePLM Yellow/Beige

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004114B

Room 15A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004214C

Room 15A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004315A

Room 6B/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Beige None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004415B

Room 6B/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Beige None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 6 of 12

Page 53: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004515C

Room 6A/Concrete block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Beige None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004616A

Room 15B/Black mastic under (9” x 9”) asbestos-containing vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 96% 4% ChrysotilePLM Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004716B

Room 15B/Black mastic under (9” x 9”) asbestos-containing vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004816C

Room 15A/Black mastic under (9” x 9”) asbestos-containing vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-004917A

Room 15/12” x 12 “ Vinyl floor tile – Blue with white and dark blue streaks

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0.0% 100%PLM Grav. Reduction None DetectedGray

4/29/2017 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005017B

Room 15/12” x 12 “ Vinyl floor tile – Blue with white and dark blue streaks

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005117C

Room 15/12” x 12 “ Vinyl floor tile – Blue with white and dark blue streaks

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005218A

Room 15/Black mastic under assumed non-asbestos vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 95% 5% ChrysotilePLM Black

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 7 of 12

Page 54: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005318B

Room 15/Black mastic under assumed non-asbestos vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005418C

Room 15/Black mastic under assumed non-asbestos vinyl floor tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017PLM Positive Stop (Not Analyzed)

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005519A

Room 15/3” Light grey vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0.0% 100%PLM Grav. Reduction None DetectedGray

4/29/2017 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-0055A19A-Adhesive

Room 15/3” Light grey vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0.0% 100%PLM Grav. Reduction None DetectedTan

4/29/2017 0.0% 100%TEM Grav. Reduction None DetectedTan

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005619B

Room 15/3” Light grey vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005719C

Room 15/3” Light grey vinyl baseboard

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005820A

Room 15/3” Light grey vinyl baseboard adhesive – Crème

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-005920B

Room 15/3” Light grey vinyl baseboard adhesive – Crème

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 8 of 12

Page 55: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006020C

Room 15/3” Light grey vinyl baseboard adhesive – Crème

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006121A

Room 6A/6” x 6” White ceramic wall tile grout - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006221B

Room 6A/6” x 6” White ceramic wall tile grout - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006321C

Room 6A/6” x 6” White ceramic wall tile grout - White

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006422A

Room 6A/6” x 6” White ceramic wall tile adhesive - Beige

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006522B

Room 6A/6” x 6” White ceramic wall tile adhesive - Beige

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006622C

Room 6A/6” x 6” White ceramic wall tile adhesive - Beige

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 0% 100%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006723A

Room 15A/12” x 12” Ceiling tile - Uniform hole pattern

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 90% 10%PLM Brown None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 9 of 12

Page 56: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006823B

Room 15A/12” x 12” Ceiling tile - Uniform hole pattern

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 90% 10%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-006923C

Room 15B/12” x 12” Ceiling tile - Uniform hole pattern

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 90% 10%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007024A

Room 15/2’ x 4’ Ceiling tile – Wide random fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 90% 10%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007124B

Room 15/2’ x 4’ Ceiling tile – Wide random fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 90% 10%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007224C

Room 15/2’ x 4’ Ceiling tile – Wide random fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 90% 10%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007325A

Room 001/2’ x 4’ Ceiling tile – Rough texture and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007425B

Room 002/2’ x 4’ Ceiling tile – Rough texture and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007525C

Room 004/2’ x 4’ Ceiling tile – Rough texture and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 80% 20%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 10 of 12

Page 57: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007626A

Corridor 41/2’ x 4’ Ceiling tile – Small fissure and pinhole, brown backing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007726B

Corridor 41/2’ x 4’ Ceiling tile – Small fissure and pinhole, brown backing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007826C

Corridor 42/2’ x 4’ Ceiling tile – Small fissure and pinhole, brown backing

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-007927A

Room 5A/2’ x 4’ Ceiling tile – Wide fissure on 2’ and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008027B

Room 5A/2’ x 4’ Ceiling tile – Wide fissure on 2’ and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008127C

Room 5A/2’ x 4’ Ceiling tile – Wide fissure on 2’ and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008228A

Room 28A/2’ x 4’ Ceiling tile – Random thin fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008328B

Room 28A/2’ x 4’ Ceiling tile – Random thin fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 11 of 12

Page 58: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551704460

702170-120

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008428C

Room 28A/2’ x 4’ Ceiling tile – Random thin fissure and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008529A

Room 28I/2’ x 4’ Ceiling tile – Large hole and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008629B

Room 28I/2’ x 4’ Ceiling tile – Large hole and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/28/2017 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551704460-008729C

Room 28I/2’ x 4’ Ceiling tile – Large hole and pinhole

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2017 80% 20%PLM Gray None Detected

Analyst(s):

PLM (23)John Biesiadecki

PLM Grav. Reduction (3)

TEM Grav. Reduction (3)

Natalie D'Amico

PLM (55)Shorthri Kalikutty

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/29/201711:05:32

Test Report:EPAMultiTests-7.32.2.D Printed: 4/29/2017 11:05AM Page 12 of 12

Page 59: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604588

702170-071

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS BENNETT P.S/702170-071

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 4/25/2016

Analyzed: 5/02/2016

Jean Daigle

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00011A

ROOM 207/2' X 4' CEILING TILE- FISSURE ON THE 4'

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 80% 20%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00021B

ROOM 207A/2' X 4' CEILING TILE- FISSURE ON THE 4'

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 80% 20%PLM Gray/White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00031C

ROOM 209/2' X 4' CEILING TILE- FISSURE ON THE 4'

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 80% 20%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00042A

ROOM 207A/INTERIOR BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

5/02/2016 0.0% 100%TEM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00052B

CORR. 59/INTERIOR BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00062C

ROOM 207A/INTERIOR BRICK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00073A

ROOM 201/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

5/02/2016 0.0% 100%TEM Grav. Reduction None DetectedGray

Test Report:EPAMultiTests-7.32.2.D Printed: 5/02/2016 02:52PM Page 1 of 3

Page 60: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604588

702170-071

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00083B

ROOM 203A/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00093C

ROOM 204/CONCRETE BLOCK MORTAR

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0% 100%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00104A-Skim Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedBlue

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-0010A4A-Base Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00114B-Skim Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedBlue

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-0011A4B-Base Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-00124C-Skim Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedBlue

Client Sample ID:

Sample Description:

Lab Sample ID: 551604588-0012A4C-Base Coat

ROOM 205A/CYPOREX

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/29/2016 0.0% 100%PLM Grav. Reduction None DetectedGray

Test Report:EPAMultiTests-7.32.2.D Printed: 5/02/2016 02:52PM Page 2 of 3

Page 61: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604588

702170-071

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

PLM (6)

PLM Grav. Reduction (6)

Jon Delos Santos

PLM (1)

PLM Grav. Reduction (2)

TEM Grav. Reduction (2)

Romeo Samson

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 05/02/201614:52:20

Test Report:EPAMultiTests-7.32.2.D Printed: 5/02/2016 02:52PM Page 3 of 3

Page 62: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551605125

7021709-071

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS BENNETT P. S/7021709-071

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 5/06/2016

Analyzed: 5/10/2016

Jean Daigle

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551605125-00015A

1'X1' CEILING TILE MASTIC ROOM 206

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/10/2016 0.0% 100%PLM Grav. Reduction None DetectedBrown

5/10/2016 0.0% 100%TEM Grav. Reduction None DetectedBrown

Client Sample ID:

Sample Description:

Lab Sample ID: 551605125-00025B

1'X1' CEILING TILE MASTIC ROOM 206A

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/10/2016 0% 100%PLM Brown None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551605125-00035C

1'X1' CEILING TILE MASTIC ROOM 206

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

5/10/2016 0% 100%PLM Brown None Detected

Analyst(s):

PLM Grav. Reduction (1)Natalie D'Amico

TEM Grav. Reduction (1)Romeo Samson

PLM (2)Shorthri Kalikutty

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 05/10/201615:40:19

Test Report:EPAMultiTests-7.32.2.D Printed: 5/10/2016 03:40PM Page 1 of 1

Page 63: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604402

702170-057

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014047B

GEORGETOWN DHS,ROOF B, VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 40% 60%PLM Brown/Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014147C

GEORGETOWN DHS,ROOF B, VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 30% 70%PLM Brown/Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014248A

MCKENZIE SMITH BENNETT, ROOF A, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/25/2016 0.0% 100%PLM Grav. Reduction None DetectedBrown/Black

4/27/2016 0.0% 100%TEM Grav. Reduction None DetectedBrown/Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014348B

MCKENZIE SMITH BENNETT, ROOF A, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 15% 85%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014448C

MCKENZIE SMITH BENNETT, ROOF A, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 15% 85%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014549A

MCKENZIE SMITH BENNETT, ROOF A, KRAFT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/25/2016 0.0% 100%PLM Grav. Reduction None DetectedBrown/Black

4/27/2016 0.0% 100%TEM Grav. Reduction None DetectedBrown/Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014649B

MCKENZIE SMITH BENNETT, ROOF A, KRAFT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 60% 40%PLM Brown/Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014749C

MCKENZIE SMITH BENNETT, ROOF A, KRAFT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 60% 40%PLM Brown/Black None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/27/2016 08:59PM Page 19 of 21

dkellyman
Highlight
Page 64: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604402

702170-057

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014850A

MCKENZIE SMITH BENNETT, ROOF B, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/25/2016 0.0% 100%PLM Grav. Reduction None DetectedGray/Black

4/27/2016 0.0% 100%TEM Grav. Reduction None DetectedGray/Black

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-014950B

MCKENZIE SMITH BENNETT, ROOF B, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 0% 100%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-015050C

MCKENZIE SMITH BENNETT, ROOF B, ROOF MEMBRANE

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 0% 100%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-015151A

MCKENZIE SMITH BENNETT, ROOF B, ASPHALT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/25/2016 0.0% 100%PLM Grav. Reduction None DetectedBlack

4/27/2016 0.0% 100%TEM Grav. Reduction None DetectedBlack

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-015251B

MCKENZIE SMITH BENNETT, ROOF B, ASPHALT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 10% 90%PLM Black None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551604402-015351C

MCKENZIE SMITH BENNETT, ROOF B, ASPHALT VAPOUR BARRIER

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/27/2016 10% 90%PLM Black None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/27/2016 08:59PM Page 20 of 21

Page 65: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L9T 5N4

Phone/Fax: 289-997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551604402

702170-057

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

PLM Grav. Reduction (49)Arabee Sathiaseelan

PLM (8)John Biesiadecki

PLM (17)Jon Delos Santos

PLM (78)

400 PLM Pt Ct (2)

Katarzyna Fila

TEM Grav. Reduction (5)Natalie D'Amico

TEM Grav. Reduction (44)Romeo Samson

Matthew Davis

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.5%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/27/201620:59:15

Test Report:EPAMultiTests-7.32.2.D Printed: 4/27/2016 08:59PM Page 21 of 21

Page 66: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 67: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 68: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 69: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 70: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 71: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 72: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 73: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 74: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 75: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 76: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 77: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 78: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 79: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 80: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 81: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 82: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass
Page 83: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903133

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS Bennett PS / 702170-202

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 3/18/2019

Analyzed: 3/25/2019

Ada Nguyen

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00011A

Room 29G/Mortar bed on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0% <1% ChrysotilePLM Beige All samples (1A-1C) in one sample bag

3/25/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct Beige

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00021B

Room 29G/Mortar bed on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0% <1% ChrysotilePLM Beige

3/25/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Beige

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00031C

Room 29G/Mortar bed on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0% <1% ChrysotilePLM Beige

3/25/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct Beige

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00042A

Room 29G/Grout on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray All samples (2A-2C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00052B

Room 29G/Grout on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00062C

Room 29G/Grout on 1x1 white ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/25/2019 05:17PM Page 1 of 5

Page 84: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903133

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00073A

Room 29G/Caulking at urinal - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100%PLM Grav. Reduction None DetectedWhite

3/25/2019 0.0% 100.0%TEM Grav. Reduction None DetectedWhite

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00083B

Room 29G/Caulking at urinal - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White All samples (3A-3C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00093C

Room 29G/Caulking at urinal - white

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00104A

Room 29G/Heavy textured block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White/Green Samples (4A-4B) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00114B

Room 29G/Heavy textured block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM White/Green None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00124C

Room 29G/Heavy textured block filler paint

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray/Blue None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00135A

Room 29E/Mortar bed on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray All samples (5A-5C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00145B

Room 29E/Mortar bed on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/25/2019 05:17PM Page 2 of 5

Page 85: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903133

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00155C

Room 29E/Mortar bed on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00166A

Room 29E/Grout on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray All samples (6A-6C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00176B

Room 29E/Grout on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00186C

Room 29E/Grout on 1x1 brown ceramic tile

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00197A

Room 29F/Grout around urinal

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray All samples (7A-7C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00207B

Room 29F/Grout around urinal

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00217C

Room 29F/Grout around urinal

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00228A

Room 29G/Caulking at door

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100%PLM Grav. Reduction None DetectedGray/Beige

3/25/2019 0.0% 100.0%TEM Grav. Reduction None DetectedGray/Beige

Test Report:EPAMultiTests-7.32.2.D Printed: 3/25/2019 05:17PM Page 3 of 5

Page 86: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903133

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00238B

Room 29G/Caulking at door

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray All samples (8A-8C) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00248C

Room 29G/Caulking at door

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00259A

Room 27K/Plaster rough coat only

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray Samples (9A-9B) in one sample bagNone Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00269B

Room 27K/Plaster rough coat only

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-00279C

Room 27K/Plaster rough coat only

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903133-002810A

Room 29/Concrete block mortar

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

3/25/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 3/25/2019 05:17PM Page 4 of 5

Page 87: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903133

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Analyst(s):

TEM Grav. Reduction (2)Anne Balayboa

PLM (21)

400 PLM Pt Ct (3)

Harman Sohi

PLM (5)Michelle Lung

PLM Grav. Reduction (2)Natalie D'Amico

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 03/25/201917:13:14

Test Report:EPAMultiTests-7.32.2.D Printed: 3/25/2019 05:17PM Page 5 of 5

Page 88: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Attn:

Proj: MS Bennett PS / 702170-202

Phone: (905) 882-5984

Fax: (905) 882-8962

Collected:

Received: 3/29/2019

Analyzed: 4/05/2019

Ada Nguyen

ARCADIS Canada Inc.

121 Granton Drive

Unit 12

Richmond Hill, ON L4B 3N4

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00011A

Room 29E/Concrete block filler paint, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/04/2019 0.0% 100.0% <1% ChrysotilePLM Blue/Peach

4/05/2019 0.0% <0.43%100% ChrysotilePLM Grav. Reduction Blue/Peach

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00021B

Room 29E/Concrete block filler paint, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/04/2019 0.0% 100.0% <1% ChrysotilePLM Blue/Peach

4/05/2019 0.0% <0.42%100% ChrysotilePLM Grav. Reduction Blue/Peach

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00031C

Room 29F/Concrete block filler paint, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0% <1% ChrysotilePLM Blue/Peach

4/05/2019 0.0% <0.46%100% ChrysotilePLM Grav. Reduction Blue/Peach

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00042A

Room 29E/Textured plaster ceiling, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/04/2019 0.0% 100.0% <1% ChrysotilePLM White

4/05/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00052B

Room 29E/Textured plaster ceiling, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/04/2019 0.0% 100.0% <1% ChrysotilePLM White

4/05/2019 0.00% 99.75% 0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00062C

Room 29F/Textured plaster ceiling, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0% <1% ChrysotilePLM White

4/05/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 1 of 6

Page 89: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00072D

Room 29F/Textured plaster ceiling, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0% <1% ChrysotilePLM White

4/05/2019 0.0% 100.0% <0.25% Chrysotile400 PLM Pt Ct White

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00083A

Room 29E/Textured plaster ceiling, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00093B

Room 29E/Textured plaster ceiling, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00103C

Room 29F/Textured plaster ceiling, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00113D

Room 29F/Textured plaster ceiling, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00124A

Room 29E/Concrete block mortar, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00134B

Room 29F/Concrete block mortar, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00144C

Room 29F/Concrete block mortar, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray/White None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 2 of 6

Page 90: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00155A

Room 114/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00165B

Room 113/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00175C

Room 113/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00185D

Room 114/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00195E

Cor 46/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00205F

Cor 46/Smooth plaster, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00216A

Room 114/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00226B

Room 113/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 3 of 6

Page 91: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00236C

Room 113/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00246D

Room 114/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00256E

Cor 46/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00266F

Cor 46/Smooth plaster, base coat, grey, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00277A

Cor 46/Textured plaster lower wall, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00287B

Cor 46/Textured plaster lower wall, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00297C

Cor 46/Textured plaster lower wall, top coat, white, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00308A

Cor 46/Textured plaster upper wall, base coat, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 4 of 6

Page 92: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00318B

Cor 46/Textured plaster upper wall, base coat, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00328C

Cor 46/Textured plaster upper wall, base coat, 1958

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00339A

Room 105/Drywall joint compound, 1956

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00349B

Room 105/Drywall joint compound, 1956

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-00359C

Room 5B/Drywall joint compound, 1956

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-003610A

Room 115/Smooth plaster wall, top coat, white 1955

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-003710B

Room 116/Smooth plaster wall, top coat, white 1955

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM White None Detected

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-003811A

Room 115/Smooth plaster wall, base coat, grey 1955

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 5 of 6

Page 93: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

EMSL Canada Inc.

2756 Slough Street Mississauga, ON L4T 1G3

Phone/Fax: (289) 997-4602 / (289) 997-4607http://www.EMSL.com / [email protected]

55DCSL97551903684

702170-202

EMSL Canada Order ID:

Customer ID:

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials for Ontario Regulation 278/05 via

EPA600/R-93/116 Method

Client Sample ID:

Sample Description:

Lab Sample ID: 551903684-003911B

Room 116/Smooth plaster wall, base coat, grey 1955

DateTEST Non-Fibrous Asbestos CommentColor Fibrous

Non-AsbestosAnalyzed

4/05/2019 0.0% 100.0%PLM Gray None Detected

Analyst(s):

PLM (8)

400 PLM Pt Ct (1)

PLM Grav. Reduction (3)

Anne Balayboa

PLM (31)

400 PLM Pt Ct (3)

Kira Ramphal

Matthew Davis or other approved signatory

or Other Approved Signatory

Reviewed and approved by:

None Detected = <0.1%. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may

not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical

method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless

otherwise noted. This report must not be used to claim product endorsement by NVLAP of any agency of the U.S. Government.

Samples analyzed by EMSL Canada Inc. Mississauga, ON NVLAP Lab Code 200877-0Initial report from: 04/05/201918:28:34

Test Report:EPAMultiTests-7.32.2.D Printed: 4/05/2019 06:28PM Page 6 of 6

Page 94: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

APPENDIX C Sample List of Suspect Asbestos-Containing Building Materials from A Guide to the Regulation Respecting Asbestos on Construction Projects and in Buildings and Repair Operations

Page 95: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

1

APPENDIX C

SAMPLE LIST OF SUSPECT ASBESTOS-CONTAINING BUILDING MATERIALS There are an estimated 3,000 products that contain asbestos. In Ontario, asbestos was widely used in sprayed-on material and in pipe and boiler insulation until 1973(1). The use of many other asbestos-containing materials continued until the mid-1980s. Asbestos is still used in the manufacture of a limited number of products, including some floor tiles, cement products, friction materials and textiles. The following list was adapted from the United States Environmental Protection Agency’s (EPA) Sample List of Suspect Asbestos Containing Materials(2). It is not an all inclusive list but is intended as a general guide to show which types of building materials may contain asbestos.

Possible Asbestos-Containing Materials in Buildings

• Acoustical Plaster • Elevator Equipment Panels

• Adhesives • Fire Doors

• Asphalt Floor Tile • Fireproofing Materials

• Base Flashing • Flooring Backing

• Blown-in (Loose Fill) Insulation • Heating and Electrical Ducts

• Boiler Insulation • High Temperature Gaskets

• Breaching Insulation • HVAC Duct Insulation

• Caulking/Putties • Joint Compounds

• Ceiling Tiles and Lay-in Panels • Pipe Insulation (corrugated air-cell,

• Cement Pipes • block, etc.)

• Cement Siding • Roofing Felt

• Cement Wallboard • Roofing Shingles

• Construction Mastics (floor tile, • Spackling Compounds

• carpet, ceiling tile, etc.) • Sprayed-on Insulation

• Cooling Towers • Taping Compounds (thermal)

• Decorative Plaster • Textured Paper Products

• Ductwork Flexible Fabric Connections • Vinyl Floor Tile

• Electrical Cloth • Vinyl Sheet Flooring

• Electrical Wiring Insulation • Vinyl Wall Coverings

• Elevator Brake Shoes • Wallboard

(1) J.S. Dupre, J.F. Mustard & R.J. Uffin, Report of the Royal Commission on Matters of Health and Safety Arising from the Use

of Asbestos in Ontario, Ontario Ministry of the Attorney General, Toronto, Ontario, 1984, page 12. (2) U.S. Environmental Protection Agency, http://www.epa.gov/Region06/6pd/asbestos/asbmatl.htm.

Page 96: Halton District School Board - SURVEY OF ASBESTOS ......insulation materials and was, therefore, not tested for asbestos content. All thermal insulation, with the exception of glass

Arcadis Canada Inc.

121 Granton Drive, Suite 12, Richmond Hill, Ontario L4B 3N4

Tel 905 882 5984

Fax 905 882 8962

www.arcadis.com