Prepared For:Sanford LabAttn: Mike Johnson

Date: December 02, 2013

Sold To: Job Name:Sanford Lab - Lead - Preconditioning AHU

Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval.

Product Summary

Qty Product1 Performance Climate Changer

Matthew DavelaarTrane3500 S. First Ave.Suite 150Sioux Falls, SD 57105-5804Phone: (605) 336-8500Cell:Fax: (605) 336-0824

The attached information describes the equipment we propose tofurnish for this project, and is submitted for your approval.

Submittal

J:\JOBS\97\23318\4\Final Submittal.doc

Page 3: ,h ò t Z µ u ] ] ( ] ^ ] } v

Table Of Contents

Product Summary..................................................................................................................... 1

Performance Climate Changer (Item A1) ................................................................................. 3Tag Data .................................................................................................................................................. 3Product Data ............................................................................................................................................ 3Performance Data.................................................................................................................................... 5Mechanical Specifications........................................................................................................................ 8As-Built................................................................................................................................................... 12Fan Curve .............................................................................................................................................. 20Accessory .............................................................................................................................................. 23Field Wiring ............................................................................................................................................ 28

Field Installed Options - Part/Order Number Summary ........................................................ 29Performance Climate Changer............................................................................................................... 29

Page 4: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 3 of 29

Tag Data - Performance Climate Changer (Qty: 1)

Item Tag(s) Qty Description Model Number

A1 AHU-1 1 Performance Climate Changer ( CSAA ) CSAA014UA

Product Data - Performance Climate Changer

Item: A1 Qty: 1 Tag(s): AHU-1Unit level options

Indoor unitUnit size 14

2.5in. integral base frameUL listed unitMultiple composite handles/latches174 Unit length142.25 Second level lengthNo seismic certification required

Controls and VFD/starterUnwired end devices

WarrantyStandard warranty only

Pipe cabinet sectionNo pipe cabinet

Coil section (Pos #1)Horizontal coilMediumNo drain panRight side - coil supplyStandard panelsUnit coil heightHeating coilSingle use coilType "UW" coil6 rows143 fins per foot nominal fin spacingAluminum finsDelta flo H (Hi efficient).016" (0.406mm) copper tubes1/2in. tube diameter (12.7 mm)Galvanized steel coil casingTurbulators

Diffuser section (Pos #2)Diffuser section

Fan section (Pos #3)Fan sectionExhaust fanDoor- right side18in. diameter AF, M pressBack-top dischargeRight side driveNEMA premium compliant ODPVoltage 460/37.5 hp1800 RPMInverter balance with SGRNo conduitField provided VFD

Coil section (Pos #4)Horizontal coilMediumNo drain panRight side - coil supplyStandard panels

Page 5: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 4 of 29

Unit coil heightHeating coilSingle use coilType "5W" coil1 row121 fins per foot nominal fin spacingAluminum finsPrima flo H (Hi efficient).020" (0.508mm) copper tubes5/8in. tube diameter (15.875 mm)Stainless steel coil casing

Filter section (Pos #5)FilterAngled filterDoor- right side

Fan section (Pos #6)Fan sectionSupply fanDoor- right side18in. diameter AF, M pressFront-top dischargeRight side driveNEMA premium compliant ODPVoltage 460/35 hp1800 RPMInverter balance with SGRNo conduitField provided VFD

Diffuser section (Pos #7)Diffuser section

Coil section (Pos #8)Horizontal coilExtended mediumStainless steel drain panRight side - drain connectionRight side - coil supplyStandard panelsUnit coil heightCooling coilSingle use coilType "UW" coil6 rows147 fins per foot nominal fin spacingAluminum finsDelta flo H (Hi efficient).016" (0.406mm) copper tubes1/2in. tube diameter (12.7 mm)Stainless steel coil casingTurbulators

Wheel (Pos #9)CDQ wheelDual path application7000 nominal CFM wheelRegeneration air bypass damperVoltage 115/1Right side driveDoors - right sideStarter

Access section (Pos #10)Access/blank/turning sectionMedium

Page 6: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 5 of 29

Performance Data - Performance Climate Changer

Tags AHU-1

Unit level options

Position

Length (in) 174.000

Width (in) 72.000

Rigging weight (lb) 4387.4

Installed weight (lb) 4552.9

Roof curb weight (lb) 0.0

Actual airflow (cfm) 4650

Unit elevation (ft) 0.00

Shipping split 1 weight (lb) 540.8

Shipping split 2 weight (lb) 803.0

Shipping split 3 weight (lb) 220.8

Shipping split 4 weight (lb) 257.2

Shipping split 5 weight (lb) 863.0

Shipping split 6 weight (lb) 468.3

Shipping split 7 weight (lb) 1294.8

Shipping split 8 weight (lb) 105.0Diffuser section

Position #2 #7

Section length (in) 14.000 14.000

Section weight (lb) 102.0 102.0

Diffuser airflow (cfm) 7168 4818

Diffuser area (sq ft) 4.32 4.32

Diffuser pressure drop (in H2O) 0.127 0.057Fan section

Position #3 #6

Section length (in) 42.500 42.500

Section weight (lb) 803.0 761.0

Fan airflow (cfm) 7168 4818

Elevation (ft) 0.00 0.00

Overall ESP (in H2O) 1.000 1.500

Total static pressure (in H2O) 3.438 3.138

Fan discharge loss pressure drop (in H2O) 0.000 0.000

Fan pressure drop (in H2O) 1.000 1.500

Fan outlet velocity (ft/min) 2486 1671

Speed (rpm) 1933 1658

Total brake horsepower (hp) 6.456 3.750

Unit static efficiency (%) 60.05 63.44

Outlet area (sq ft) 2.88 2.88

Motor hertz (Hz) 60 60Access section

Position #10

Section length (in) 14.000

Section weight (lb) 105.0Coil section

Position #1 #4 #8

Section length (in) 14.000 14.000 19.000

Section weight (lb) 438.8 220.8 468.3

Coil performance airflow (cfm) 7168 7000 4818

Unit airflow (cfm) 7168 7000 4818

Coil face area (sq ft) 13.65 12.50 13.65

Coil face velocity (ft/min) 525 560 353

Air pressure drop (in H2O) 0.686 0.128 0.526

Coil section pressure drop (in H2O) 0.686 0.128 0.526

Coil rigging weight (lb) 231.5 68.1 232.8

Page 7: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 6 of 29

Tags AHU-1

Coil installed weight (lb) 304.8 86.8 306.3

Top or single coil dry weight (lb) 231.5 68.1 232.8

Leaving dry bulb (F) 123.72 85.00 49.00

Leaving wet bulb (F) - - 48.90

Entering dry bulb (F) 85.00 70.00 70.00

Entering wet bulb (F) - - 69.40

Fluid type Water Water Water

Coil fluid percentage (%) 100.00 100.00 100.00

Entering fluid temperature (F) 130.00 130.00 42.00

Leaving fluid temperature (F) 115.00 115.00 56.00

Fluid temperature rise (F) - - 14.00

Fluid temperature drop (F) 15.00 15.00 -

Standard fluid flow rate (gpm) 40.22 15.22 42.65

Fluid pressure drop (ft H2O) 9.56 0.78 12.18

Fluid velocity (ft/s) 2.76 1.68 2.93

Fluid volume (gal) 8.79 2.25 8.79

Sensible capacity (MBh) - - 112.37

Total capacity (MBh) 301.00 113.87 299.65Filter section

Position #5

Section length (in) 26.500

Section weight (lb) 257.2

Filter airflow (cfm) 4818

Filter area (sq ft) 18.06

Filter condition Mid-life

Filter pressure drop (in H2O) 0.562

Filter section pressure drop (in H2O) 0.562

Filter face velocity (ft/min) 267Wheel

Position #9

Section length (in) 57.500

Section weight (lb) 1294.8

Leaving supply airflow (cfm) 4650

Regeneration airflow (cfm) 7000

Mixed regeneration airflow (cfm) 7168

Cross Leakage Airflow (cfm) 168

Supply air wheel PD (in H2O) 0.493

Greatest wheel exhaust PD (in H2O) 0.000

Regeneration air wheel PD (in H2O) 0.854

Max supply level module PD (in H2O) 0.493

Max exhaust module PD (in H2O) 1.497

Max regeneration air module PD (in H2O) 1.497

Regeneration air bypass damper area (sq ft) 3.05

Entering regeneration ESP (in H2O) 0.500

Leaving supply ESP (in H2O) 0.500

Mixed regeneration air DB (F) 84.16

Mixed regeneration air RH (%) 60.60

Regeneration LDB (F) 85.00

Regeneration EDB (F) 85.00

Regeneration leaving RH (%) 59.70

Regeneration entering RH (%) 59.70

Regeneration leaving HR (gr/lb) 108

Leaving supply air DB (F) 56.83

Leaving supply air RH (%) 59.93

Leaving supply air HR (gr/lb) 41

Filter area (sq ft) 14.44

Page 8: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 7 of 29

Tags AHU-1

Filter condition Mid-life

Filter pressure drop (in H2O) 0.643

Total filter pressure drop (in H2O) 0.643

Filter face velocity (ft/min) 485

Sensible energy saved - CDQ (MBh) 0.00

Page 9: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 8 of 29

Mechanical Specifications - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

GENERAL

Lifting InstructionsThe air handling units must be rigged, lifted, and installed in strict accordance with the Installation, Operation, andMaintenance manual (CLCH-SVX07B-EN). The units are also to be installed in strict accordance with the specifications.Units may be shipped fully assembled or disassembled to the minimum functional section size in accordance withshipping and job site requirements.

Indoor units shall be shipped on an integral base frame (variable from the standard 2.5" to 8" height) for the purpose ofmounting units to a housekeeping pad and providing additional height to properly trap condensate from the unit. Theintegral base frame may be used for ceiling suspension, external isolation, or as a housekeeping pad. Indoor sizes 3 to30 will also be shipped with a shipping skid designed for forklift transport. Refer to the unit As-Built or Product Datasection of the submittal for the base frame height of each unit.

All units will be shipped with an integral base frame designed with the necessary number of lift points for safeinstallation. All lifting lugs are to be utilized during lift. The lift points will be designed to accept standard rigging devicesand be removable after installation. Units shipped in sections will have a minimum of four points of lift.

Per ASHRAE 62.1 recommendation, indoor air handling units will be shipped stretch-wrapped to protect unit fromin-transit rain and debris.

Installing contractor is responsible for long term storage in accordance with the Installation, Operation, and Maintenancemanual (CLCH-SVX07B-EN).

Unit shall be UL and C-UL Listed.

Air-handling performance data shall be certified in accordance with AHRI Standard 430.

Unit sound performance data shall be provided using AHRI Standard 260 test methods and reported as sound power.Trane, in providing this program and data, does not certify or warrant NC levels. These levels are affected by factorsspecific to each application and/or installation and therefore unable to be predicted or certified by Trane.

Unit Construction

All unit panels shall be 2" solid, double-wall construction to facilitate cleaning of unit interior. Unit panels shall beprovided with a mid-span, no-through-metal, internal thermal break. Casing thermal performance shall be such thatunder 55°F supply air temperature and design conditions on the exterior of the unit of 81°F dry bulb and 73°F wet bulb,condensation shall not form on the casing exterior.

All exterior and interior indoor AHU panels will be made of galvanized steel.

Unit Paint

Unit to ship unpainted from factory. Unit to be painted by 3rd party finisher, or by painting contractor at job site.

Casing DeflectionThe casing shall not exceed 0.0042 inch deflection per inch of panel span at 8 inch static pressure. Total maximumstatic shall not exceed +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressuresections.

Floor ConstructionThe unit floor shall be of sufficient strength to support a 300.0 lb load during maintenance activities and shall deflect nomore than 0.0042 inch per inch of panel span.

InsulationPanel insulation shall provide a minimum thermal resistance (R) value of 13 ft²-h-ºF/Btu throughout the entire unit.Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation isprevented. Panel insulation shall comply with NFPA 90A.

Drain Pan

Page 10: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 9 of 29

All cooling coil sections shall be provided with an insulated, double-wall, galvanized or stainless steel drain pan. Toaddress indoor air quality (IAQ), the drain pan shall be designed in accordance with ASHRAE 62.1 being of sufficientsize to collect all condensation produced from the coil and sloped in two planes promoting positive drainage to eliminatestagnant water conditions. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter topreclude drain pan overflow under any normally expected operating condition. All drain pan threaded connections shallbe visible external to the unit. Drain connections shall be of the same material as the primary drain pan and shall extenda minimum of 2-1/2" beyond the base to ensure adequate room for field piping of condensate drain traps.Refer to Product Data for specific information on which sections are supplied with a drain pan, the drain pan materialand connection location.

FILTER SECTIONA section shall be provided to support the filter rack as indicated throughout the unit. Refer to Product Data and As-Builtsections of the submittal for specific locations within each unit.

Primary Filters

2-inch pleated media filters made with 100% synthetic fibers that are continuously laminated to a supported steel-wiregrid with water repellent adhesive shall be provided. Filters shall be capable of operating up to 625 fpm face velocitywithout loss of filter efficiency and holding capacity. The filters shall have a MERV 8 rating when tested in accordancewith the ANSI/ASHRAE Standard 52.2.

COIL SECTIONThe coil section shall be provided complete with coil and coil holding frame. The coils shall be installed such thatheaders and return bends are enclosed by unit casings. If two or more cooling coils are stacked in the unit, anintermediate drain pan shall be installed between each coil and be of the same material as the primary drain pan. Likethe primary drain pan, the intermediate drain pan shall be designed being of sufficient size to collect all condensationproduced from the coil and sloped to promote positive drainage to eliminate stagnant water conditions. Theintermediate pan shall begin at the leading face of the water-producing device and be of sufficient length extendingdownstream to prevent condensate from passing through the air stream of the lower coil. Intermediate drain pan shallinclude downspouts to direct condensate to the primary drain pan. The outlet shall be located at the lowest point of thepan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition.

Hydronic coils shall be supplied with factory installed drain and vent piping to unit casing exterior. Piping is to facilitatefield installation of automatic venting or drain valves on coils, which are not supplied with unit. Refer to the Product Datasection of the submittal for the units and/or coils supplied with drain and vent piping.

No casing penetrations supplied for hydronic drain and vents. If required, piping contractor will need to drill drain andvent penetrations using factory located features provided in coil panel.

Water Coils (UW, UU, UA, W, 5W, 5A, WD, 5D, D1, D2, P, or TT)The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 5/8-inch tubes.Fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casingmay be galvanized or stainless steel. Refer to the Product Data section of the submittal for the coil casing material.The coils shall be proof-tested to 300 psig and leak-tested under water to 200 psig. Coils containing water or ethyleneglycol are certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils CertificationProgram which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of theStandard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. Propylene glycol and calciumchloride, or mixtures thereof, are outside the scope of AHRI Standard 410 and, therefore, do not require AHRI 410 ratingor certification.

Coil header connections are constructed of cast iron with female connections, steel block with female connections orsteel pipe with male connections.

Tubes are 1/2" [13mm] OD 0.016" [0.406mm] thick copper.

Tubes are 5/8" [16mm] OD 0.020" [0.508 mm] thick copper.

ACCESS/INSPECTION / TURNING SECTIONA section shall be provided to allow additional access/inspection of unit components and space for field-installedcomponents as needed. An access door shall be provided for easy access. All access sections shall be complete witha double-wall, removable door downstream for inspection, cleaning, and maintenance. Interior and exterior door panels

Page 11: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 10 of 29

shall be of the same construction as the interior and exterior wall panels, respectively. All doors downstream of coolingcoils shall be provided with a thermal break construction of door panel and door frame.

Fans that are selected with inverter balancing shall first be dynamically balanced at design RPM. The fans then will bechecked in the factory from 25% to 100% of design RPM to insure they are operating within vibration tolerancespecifications, and that there are no resonant frequency issues throughout this operating range. Inverter balancing thatrequires lockout frequencies inputted into a variable frequency drive to in order to bypass resonant frequencies shall notbe acceptable. If supplied in this manner by the unit manufacturer, the contractor will be responsible for rebalancing inthe field after unit installation. Fans selected with inverter balancing shall have a maintenance free, circumferentialconductive micro fiber shaft grounding ring installed on the fan motor to discharge shaft currents to ground.

AF FAN SECTIONThe fan type shall be provided as required for stable operation and optimum energy efficiency. The fan shall be adouble-width, double-inlet, multiblade-type, airfoil (AF) fan. The fan shall be equipped with self-aligning, antifrictionbearings with an L-50 life of 200,000 hours, as calculated per ANSI/AFBMA Standard 9. For any bearing requiringrelubrication, the grease line shall be extended to the fan support bracket on the drive side. The fan shall be staticallyand dynamically balanced at the factory as a complete fan assembly (fan wheel, motor, drive, and belts). The fan shaftshall not exceed 75 percent of its first critical speed at any cataloged speed. Fan wheels shall be keyed to the fan shaftto prevent slipping. The fan shafts shall be solid steel. The fan section shall be provided with an access door on the driveside of the fan. Fan performance shall be certified as complying with AHRI Standard 430.

Drive Service Factor

The drives shall be constant speed with fixed-pitch sheaves. The drives shall be selected at a minimum 50 percentlarger than the motor brake horsepower (1.5 service factor).

Motor FrameThe motor shall be mounted integral to the isolated fan assembly and furnished by the unit manufacturer. The motor ismounted inside the unit casing on an adjustable base to permit adjustment of drive belt tension (not applicable for directdrive plenum fans). The motor shall meet or exceed all NEMA Standards Publication MG 1 requirements and complywith NEMA Premium efficiency levels when applicable except for fractional horsepower motors which are not coveredby the NEMA classification. The motor shall be T-frame, squirrel cage with size, type, and electrical characteristics asshown on the equipment schedule. Refer to the Product Data section for selected fan motors within each unit.

Two-Inch Spring IsolatorsThe fan and motor assembly (on sizes 10 to 120) shall be internally isolated from the unit casing with 2-inch (50.8 mm)deflection spring isolators, furnished and installed by the unit manufacturer. The isolation system shall be designed toresist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements.

DIFFUSER SECTIONA diffuser section shall be provided immediately downstream of the fan section. The diffuser shall provide equal airdistribution to blow-thru components immediately downstream of the diffuser. Diffusers attached directly to the fandischarge are not acceptable.

Field Wired Control SystemFactory-mounted direct-digital control (DDC) control points shall be engineered, and mounted by the air handlermanufacturer to reduce installed costs, improve reliability, and save time at unit startup. The control points as selectedby section will require field wiring at the job site. Review unit submittal drawings to verify there is sufficient space foraccess to control points for field wiring. All factory-mounted controls points shall be covered by the air handlermanufacturer's standard warranty.

COOL DRY QUIET (CDQ(TM)) DESICCANT WHEEL SECTIONThe air handling unit shall be provided with a CDQ desiccant wheel to control space humidity based on the specifiedrequirements. The wheel media shall meet the flammability requirements governing this class of products and shall be aUL-recognized component in accordance with UL 1812 and UL1995. The CDQ desiccant wheel speed is not modulatedfor temperature control nor recommended. The CDQ wheel is for humidity control and should be turned off during winterheating. Supply temperature is controlled by the cooling coil or a reheat coil.

Wheel ConstructionThe CDQ desiccant wheel shall be constructed of a synthetic matrix with a type III desiccant. The wheel shall bestructurally reinforced with a spoke system to minimize wheel deflection. All diameter and perimeter seals shall beprovided as part of the cassette assembly. The drive system shall consist of a heavy-duty fractional horsepower A/Cgear motor mounted in the cassette.

Page 12: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 11 of 29

CDQ Wheel Drive SystemThe motor shall have permanently lubricated bearings. The bearings, which support rotation of the wheel around acenter shaft, shall be provided with grease fittings for periodic lubrication.

Maintenance and Access DoorsThe wheel matrix shall be cleanable. The desiccant shall not dissolve in the presence of water or high humidity. Accessdoors shall be provided immediately upstream and downstream of the CDQ wheel cassette. Adequate space shall beprovided for cleaning, service, and maintenance of the wheel, motor, bearing, and belt.

Primary Filters

2 inch pleated media filters made with 100% synthetic fibers that are continuously laminated to a supportedsteel wire grid with water repellent adhesive shall be provided. Filters shall be capable of operating up to 625fpm face velocity without loss of filter efficiency and holding capacity. The filters shall have a MERV 8 ratingwhen tested in accordance with the ANSI/ASHRAE Standard 52.2.

Page 13: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 12 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Page 14: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 13 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Page 15: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 14 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE

Unit size: 14

Product group: Indoor unitIntegral base frame: 2.5in. integral base frame

Paint: Unpainted/field painted outdoor

Job Name:Actual airflow: 4650 cfmSales Office:

Unit Casing: 2in Double Wall

Proposal Number:

Rigging/Installed Weight: 4387.4 lb/ 4552.9 lb

Performance Climate ChangerAir Handlers

Pos #12345678910

ModuleCoil sectionDiffuser sectionFan sectionCoil sectionFilter sectionFan sectionDiffuser sectionCoil sectionWheelAccess section

Length141442 1/21426 1/242 1/2141957 1/214

Weight438.80102.00803.00220.80257.20761.00102.00468.301294.80105.00

Installed Unit Weight 4552.90 lbs

1234 59

72

Basic Overall Plan View: Top - Measurements in inches

S1S2S3

S4S5S6

S7

S8

2 1/2

2 1/2

1234

5678

9

10

174 1/8

83

1/4

Overall Elevation View: Right - Shipping splits indicated by bold outline. - Measurements in inches

For maneuvering purposes, include 1.125 inches to each ship split length for overlapping panel flange. Flange will not add to overall installed unit length shown.

Page 16: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 15 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE

Unit size: 14

Product group: Indoor unitIntegral base frame: 2.5in. integral base frame

Paint: Unpainted/field painted outdoor

Job Name:Actual airflow: 4650 cfmSales Office:

Unit Casing: 2in Double Wall

Proposal Number:

Rigging/Installed Weight: 4387.4 lb/ 4552.9 lb

Performance Climate ChangerAir Handlers

1234 59

30 1/217 3/4

11

1/2

141442 1/2

14 26 1/2

42 1/2141957 1/2

1.378 dia elec con(NEMA)

25/8

6

5 5/8

72

Right Side of Unit Detailed Plan View: Top - Measurements in inches

5678910

1414

42 1/214 26 1/2

42 1/21419

57 1/2

Left Side of Unit Detailed Plan View: Bottom - Measurements in inches

Page 17: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 16 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE

Unit size: 14

Product group: Indoor unitIntegral base frame: 2.5in. integral base frame

Paint: Unpainted/field painted outdoor

Job Name:Actual airflow: 4650 cfmSales Office:

Unit Casing: 2in Double Wall

Proposal Number:

Rigging/Installed Weight: 4387.4 lb/ 4552.9 lb

Performance Climate ChangerAir Handlers

1 2 3 4

5 6 7 8

9

10

1414

42 1/2 1426 1/2

42 1/214 19

57 1/22 1/2

2 1/2

41

1/2

Detailed Elevation View: Left - Measurements in inches

2 1/2 33

/8

4 1/44 1/4 4 1/4

19

2 1/2 4 1/4

34

3/4

34

3/4

14

1/4

76

1/2

76

1/2

1234

5678

9

10

3 1/8 2 1/822 1/89 1/2

17 3/42

40 5/8

17"

22"17"

11

1/2

15"

15"

1" N.P.T.E

174 1/8

83

1/4

Detailed Elevation View: Right - Measurements in inches

Page 18: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 17 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

OPENING AND DIMENSIONS MAY VARY FROM CONTRACT DOCUMENTS / RETURN OF APPROVED DRAWINGS CONSTITUTES ACCEPTANCE OF THESE VARIANCES / NOT TO SCALE

Unit size: 14

Product group: Indoor unitIntegral base frame: 2.5in. integral base frame

Paint: Unpainted/field painted outdoor

Job Name:Actual airflow: 4650 cfmSales Office:

Unit Casing: 2in Double Wall

Proposal Number:

Rigging/Installed Weight: 4387.4 lb/ 4552.9 lb

Performance Climate ChangerAir Handlers

1

5

68

68

35

35

22

72

2 1/24 1/2

2 1/24 1/2

41

1/2

Detailed Elevation View: Back - Measurements in inches

83

1/4

4

10

2 1/2

2 1/2

Detailed Elevation View: Front - Measurements in inches

Page 19: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 18 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Page 20: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 19 of 29

As-Built - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Page 21: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 20 of 29

Fan Curve - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Overall Unit Acoustics

63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

Discharge 86 72 67 64 58 60 56 50Casing 85 81 68 76 72 53 39 32

Ducted Inlet 94 89 79 79 72 70 67 59

Page 22: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 21 of 29

Fan Curve - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

5.0

0h

p

7.5

0h

p

10

.00

hp

15

.0

0h

p

1000 RPM

1200 RPM

1400 RPM

1600 RPM

1800 RPM

2000 RPM

2200 RPM

2400 RPM

2450 RPM

45 %WO

50 %WO

60 %WO

70 %WO

80 %WO

90 %WO

BHP adjusted 5% for approximate drive lossUnitSize: 18AA

Motor Frequency: 60.00HzOperating Airflow: 7168.00 cfm

Operating Static Pressure: 3.44 in H2OOperating RPM: 1933.00

Operating Brake Power: 6.46 hpAltitude: 0.00 ft

Design Temp: 70.00 FMax BHP: 6.84 hpEfficiency: 60.05 %

Date: 12/2/13Datafile: C:\Program Files\Trane Company\TOPSS\CSAA\Csaa_fans.ran

3536

0

1

2

3

4

5

6

7

8

9

0 2500 5000 7500 10000 12500 15000

ExhaustSize 14Horizontal Draw-Thru 18inchAF MPress - Single Fan

To

tal

Sta

tic

Pre

ss

ur

e(

inH

2O

)

Airflow(cfm)

Size 14Horizontal Draw-Thru 18inchAF MPress

63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

Discharge 87 74 72 73 69 69 67 60Inlet + Casing 90 87 77 77 70 68 63 55

Casing 81 79 67 76 72 53 38 31DuctedInlet 90 86 77 77 70 68 63 55

Page 23: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 22 of 29

Fan Curve - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

5.0

0h

p

7.5

0h

p

10

.0

0h

p

15

.00

hp

1000 RPM

1200 RPM

1400 RPM

1600 RPM

1800 RPM

2000 RPM

2200 RPM

2400 RPM

2450 RPM

45 %WO

50 %WO

60 %WO

70 %WO

80 %WO

90 %WO

BHP adjusted 5% for approximate drive lossUnitSize: 18AA

Motor Frequency: 60.00HzOperating Airflow: 4818.00 cfm

Operating Static Pressure: 3.14 in H2OOperating RPM: 1658.00

Operating Brake Power: 3.75 hpAltitude: 0.00 ft

Design Temp: 70.00 FMax BHP: 3.98 hpEfficiency: 63.44 %

Date: 12/2/13Datafile: C:\Program Files\Trane Company\TOPSS\CSAA\Csaa_fans.ran

3536

0

1

2

3

4

5

6

7

8

9

0 2500 5000 7500 10000 12500 15000

SupplySize 14Horizontal Draw-Thru 18inchAF MPress - Single Fan

To

tal

Sta

tic

Pre

ss

ur

e(

inH

2O

)

Airflow(cfm)

Size 14Horizontal Draw-Thru 18inchAF MPress

63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz

Discharge 86 72 67 64 58 60 56 50Inlet + Casing 94 88 77 76 69 66 66 58

Casing 83 78 64 70 66 47 35 26Ducted Inlet 93 87 76 76 69 66 66 58

Page 24: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 23 of 29

Accessory - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

Base Detail

2 1/2"

Page 25: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 24 of 29

Accessory - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

D(I

nte

rnal

6 48

59

61

A(f

ilter,

gas

heat)

Cle

ara

nce

item

s

VF

D-

show

n)

B(c

oil,

hum

idifi

er)

D(E

xte

rnal

Sta

rter

or

C(U

VLig

hts

)

483

484

48

61

59

61

8 48

10

48

12

48

66

61

77

82

61

61

17

48

14

48

21

48

87

61

87

61

95

64

66

52

156

64

48

128

25

48

30

48

35

48

95

109

64

64

11

5

64

40

50

48

57

48

141

64

64

141

64

80

56

100

58

120

58

156

64

170

197

64

64

48

89

48

56

ExtV

estible

)

IntV

estib

le)

F(G

as

Heat

Sta

rter

or

E(f

an)

F(G

as

Heat

VF

D)

48

N/A

48

48

48

N/A

N/A

N/A

100

48

48 90

48

51

48

54

108

63

74

79

48

105

61

48

58

10

0

48

60

115

84

84

92

48

170

93

15

3

140

125

48

66

48

66

115

118

48

66

136

92

106

112

48

70

48

77

156

48

77

156

138

138

N/A

48 93

179

48

101

48

101

180

153

167

194

VF

D

59

C(T

CA

C)

43

59

63

75

81

83

83

58

83

58

83

75

83

83

83

83

75

83

52

56

58

58

57

48

110

64

48

66

N/A

N/A83

48

48

48

48

48

48

48

48

48

48

48

48

48

48

48

48

50

48

110

64

48

66

N/A

N/A83

48

48

96

40 64

N/A

N/A

48 60

8348

48

9635 64

N/A

N/A48

60

59

48

30

48

87

64

48

58

N/A

N/A83

48

25

48

77

64

48 51

N/A

N/A75

48

21

48

77

64

48

51

N/A

N/A

75

48

TA

LL

TA

LL

TA

LL

TA

LL

TA

LL

TA

LL

TA

LL

Ga

sh

ea

t

Acce

ss

do

or

F

E

Filt

er

mix

ing

box

Note

:A

ta

min

imum

,th

ebelo

wcl

eara

nce

dim

ensi

ons

are

reco

mm

end

ed

on

one

sid

eofth

eunit

for

regula

rserv

ice

an

dm

ain

ten

ance.

Refe

rto

as-

built

subm

itta

lfo

rlo

cations

of

item

ssu

chas

filte

raccess

doors

,coil,

pip

ing

connectio

ns,

moto

rlo

catio

ns,etc

.S

uffic

ien

tcl

eara

nce

mu

stb

ep

rovid

ed

on

all

sid

es

of

unit

for

rem

ovalo

fpane

lsor

sect

ion-t

o-s

ect

ion

atta

chm

ent.

Cle

ara

nce

for

sta

rters

,V

FD

s,or

oth

er

hig

h-v

oltage

de

vice

sm

ust

be

pro

vid

ed

pe

rN

EC

require

ments

.

D

CB

A

Coil

UV

Lig

hts

or

TC

AC

Fa

n

EX

AM

PL

EU

NIT

-N

OT

CO

NF

IGU

RE

DA

SS

ELE

CT

ED

.

Page 26: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 25 of 29

Accessory - Performance Climate ChangerItem: A1 Qty: 1 Tag(s): AHU-1

2B

1B

OF

F

AT

TA

CH

EA

RT

HG

RO

UN

D

L1

L2

W10

9A

,B

14A

10B

13A

11A

1S

10

1K

40

1K

40

1K

40

1T

B1

3-4

1T

B13

-31

OL

1K

40

1T

B13

-1

1T

B13

-2

9A

9B

12

A

AU

TO

HA

ND

W11

1C

B11

1A

,B

2A

,B

1O

L

1O

L

1O

L

2A

1A

T1

T2

1P

7-3

1J7-3

1P

7-2

1J7-2

1P

7-1

1J7-1

GR

D

WH

T

BLK

GR

N

1K

38

TO

CO

OL

DR

Y

QU

IET

MO

TO

RC

US

TO

ME

RS

UP

PL

IED

PO

WE

R

NO

TE

(S):

1

DA

SH

ED

LIN

ES

IND

ICA

TE

RE

CO

MM

EN

DE

DF

IELD

WIR

ING

BY

OT

HE

RS

.

PH

AN

TO

MLIN

ES

IND

ICA

TE

CO

NT

RO

LO

PT

ION

.R

EF

.C

ON

TR

OL

PA

NE

LS

CH

EM

AT

ICF

OR

SP

EC

IFIC

DE

TA

IL.

2

ALL

FIE

LD

WIR

ING

MU

ST

BE

INA

CC

OR

DA

NC

EW

ITH

TH

EN

AT

ION

AL

ELE

CT

ICA

LC

OD

E,S

TA

TE

,A

ND

LO

CA

LR

EQ

UIR

EM

EN

TS

.O

TH

ER

CO

UN

TR

IES

AP

PL

ICA

BLE

NA

TIO

NA

LA

ND

/OR

LO

CA

LR

EQ

UIR

EM

EN

TS

SH

ALL

AP

PL

Y.

FIE

LD

CO

ND

UC

TO

RS

SH

ALL

HA

VE

INS

ULA

TIO

N

RA

TIN

GN

OT

LE

SS

TH

AN

60

0V

CO

PP

ER

CO

ND

UC

TO

RS

ON

LY

.

3

MIN

IMU

MC

IRC

UIT

AM

PA

CIT

Y,

MA

XIM

UM

FU

SE

SIZ

E,A

ND

DIS

CO

NN

EC

T

SIZ

EA

RE

CA

LC

ULA

TE

DB

AS

ED

ON

TH

EIN

VE

RT

ER

INP

UT

LIN

E

CU

RR

EN

TS

PE

RA

RT

ICLE

430-2

OF

TH

EN

AT

ION

AL

EL

EC

TR

ICA

L

CO

DE

.

6

CLO

SE

ST

OR

UN

AU

TO

MO

DE

OR

BY

PA

SS

AU

TO

FO

RO

PT

ION

VF

DO

R

ST

AR

TE

R.

9

RE

MO

VE

JUM

PE

RA

ND

INS

TA

LL

FIE

LD

SA

FE

TY

CO

NT

AC

T.

10 F

IEL

DS

UP

PLIE

DC

ON

TA

CT

S.

16 O

VE

RL

OA

DR

ELA

YT

RIP

SE

TT

ING

MU

ST

BE

AD

JUS

TE

DT

O

CO

RR

ES

PO

ND

WIT

HT

HE

MO

TO

RF

ULL

LO

AD

CU

RR

EN

TA

SS

HO

WN

ON

TH

EM

OT

OR

NA

ME

PLA

TE

.

27 A

TT

AC

HG

RO

UN

DO

RE

QU

IPM

EN

TG

RO

UN

D.C

ON

TA

CT

AU

XIL

LA

RY

TE

RM

INA

LS

TR

IPC

ON

TR

OL

CIR

CU

IT

HA

ND

/OF

F/A

UT

OS

WIT

CH

OV

ER

LO

AD

RE

LA

Y

ST

AR

TE

RC

ON

TA

CT

OR

ST

AR

T/S

TO

PR

ELA

Y

CIR

CU

ITB

RE

AK

ER

1T

B13

1S

10

1O

L

DE

VIC

E

DE

SIG

NA

TIO

N

1K

40

1K

38

1C

B11

DE

SC

RIP

TIO

N

LE

GE

ND

DE

VIC

EP

RE

FIX

LO

CA

TIO

NC

OD

E

LO

CA

TIO

N

AIR

HA

ND

LE

RS

EC

TIO

N

LO

WV

OL

TA

GE

PA

NE

L(U

NIT

SC

HE

MA

TIC

)H

IGH

VO

LT

AG

EP

AN

EL

321

AR

EA

96

95

A2

A1

33

9

10

1K

40

AU

X

13

14

16

27

6

INC

LU

DIN

GR

EM

OT

ED

ISC

ON

NE

CT

SA

ND

AV

ER

TIS

SE

ME

NT

AD

VE

RT

EN

CIA

NE

PA

SR

ES

PE

CT

ER

CE

SM

ES

UR

ES

DE

FO

LL

OW

LO

CK

OU

TA

ND

TA

GP

RO

CE

DU

RE

S

BE

FO

RE

SE

RV

ICIN

G.

INS

UR

ET

HA

TA

LL

MO

TO

RC

AP

AC

ITO

RS

HA

VE

DIS

CH

AR

GE

D

ST

OR

ED

VO

LT

AG

E.

UN

ITS

WIT

HV

AR

IAB

LE

INS

TR

UC

TIO

NS

FO

RC

AP

AC

ITO

RD

ISC

HA

RG

E.

SE

RV

ICIN

GC

OU

LD

RE

SU

LT

IND

EA

TH

OR

INS

TR

UC

TIO

NS

DE

L'E

NT

RA

ÎNE

ME

NT

PO

UR

VIT

ES

SE

VA

RIA

BLE

,S

ER

EP

OR

TE

RA

UX

CH

AR

S.

DA

NS

LE

CA

SD

'UN

ITÉ

S

LE

SC

ON

DE

NS

AT

EU

RS

DE

SM

OT

EU

RS

SO

NT

TO

UT

EIN

TE

RV

EN

TIO

N.

RIF

IER

QU

ET

OU

S

VE

RR

OU

ILLA

GE

ET

DE

TIQ

UE

TT

ES

AV

AN

T

OU

VR

IRLE

SS

EC

TIO

NN

EU

RS

ÀD

IST

AN

CE

,

PR

ÉC

AU

TIO

NP

EU

TE

NT

RA

ÎNE

RD

ES

BL

ES

SU

RE

SG

RA

VE

SP

OU

VA

NT

ÊT

RE

CH

AR

GE

RLE

SC

ON

DE

NS

AT

EU

RS

.

MO

RT

ELLE

S.

TE

NS

ION

DA

NG

ER

EU

SE

!

SP

EE

DD

RIV

E,R

EF

ER

TO

DR

IVE

FA

ILU

RE

TO

DO

TH

EA

BO

VE

BE

FO

RE

CO

MP

OR

TA

NT

DE

SE

NT

RA

ÎNE

ME

NT

PU

ISS

UIV

RE

LE

SP

RO

DU

RE

SD

E

CO

UP

ER

TO

UT

ES

LE

ST

EN

SIO

NS

ET

SE

RIO

US

INJU

RY

.WA

RN

ING

DIS

CO

NN

EC

TA

LL

EL

EC

TR

ICP

OW

ER

HA

ZA

RD

OU

SV

OLT

AG

E!

CO

NS

ULT

EL

AS

INS

TR

UC

CIO

NE

SP

AR

ALA

DIR

EC

CIÓ

ND

EV

EL

OC

IDA

DV

AR

IAB

LE

,

PA

RA

LA

SU

NID

AD

ES

CO

NE

JE

DE

SE

RV

ICIO

.A

SE

RE

SE

DE

QU

ET

OD

OS

ET

IQU

ET

AD

OA

NT

ES

DE

PR

OC

ED

ER

AL

SIG

ALO

SP

RO

CE

DIM

IEN

TO

SD

EC

IER

RE

Y

INC

LU

SO

LA

SD

ES

CO

NE

XIO

NE

SR

EM

OT

AS

Y

OS

ER

IAS

LE

SIO

NE

SP

ER

SO

NA

LE

S.

IND

ICA

DO

,P

OD

RÍA

OC

AS

ION

AR

LA

MU

ER

TE

EL

NO

RE

ALIZ

AR

LO

AN

TE

RIO

RM

EN

TE

DE

SC

AR

GA

DE

LC

ON

DE

NS

AD

OR

.

LO

SC

AP

AC

ITO

RE

SD

EL

MO

TO

RH

AY

AN

iVO

LT

AJE

PE

LIG

RO

SO

!

DE

SC

AR

GA

DO

EL

VO

LT

AJE

ALM

AC

EN

AD

O.

DE

SC

ON

EC

TE

TO

DA

LA

EN

ER

GÍA

ELÉ

CT

RIC

A,

FA

ILU

RE

TO

DO

SO

MA

YC

AU

SE

DA

MA

GE

TO

TH

E

UN

ITT

ER

MIN

ALS

AR

EN

OT

DE

SIG

NE

DT

OA

CC

EP

T

N'U

TIL

ISE

RQ

UE

DE

SC

ON

DU

CT

EU

RS

EN

CU

IVR

E!

LE

SB

OR

NE

SD

EL'U

NIT

ÉN

ES

ON

TP

AS

CO

UE

S

PO

UR

RE

CE

VO

IRD

'AU

TR

ES

TY

PE

SD

EC

ON

DU

CT

EU

RS

.

L'U

TIL

ISA

TIO

ND

ET

OU

TA

UT

RE

CO

ND

UC

TE

UR

PE

UT

SIN

OLO

HA

CE

,P

UE

DE

OC

AS

ION

AR

DA

ÑO

AL

EQ

UIP

O.

PA

RA

AC

EP

TA

RO

TR

OS

TIP

OS

DE

CO

ND

UC

TO

RE

S.

LA

ST

ER

MIN

ALE

SD

ELA

UN

IDA

DN

OE

ST

ÁN

DIS

AD

AS

¡UT

ILIC

NIC

AM

EN

TE

CO

ND

UC

TO

RE

SD

EC

OB

RE

!

EN

DO

MM

AG

ER

L'É

QU

IPE

ME

NT

.

PR

EC

AU

CIÓ

N

OT

HE

RT

YP

ES

OF

CO

ND

UC

TO

RS

.

EQ

UIP

ME

NT

.

AT

TE

NT

ION

US

EC

OP

PE

RC

ON

DU

CT

OR

SO

NLY

!

CA

UT

ION

200

29

Page 27: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 26 of 29

Accessory - Performance Climate ChangerTrap ScheduleItem: A1 Qty: 1 Tag(s): AHU-1

UnitTag(s)

UnitSize

EnteringExt. StaticPressure(in H2O)

DischargeExt. StaticPressure(in H2O)

Drain panSectionLocation

Recommended Trap Dimensions1

SelectedBaserail

Height (in)1

H(in)

J(in)

L(in)

AHU-12

Unit size 14 0.750 0.750Coil section

[8]0.500 1.743 3.243 2.500

1Trap height and selected baserail heights should be reviewed to determine appropriate housekeeping pad height.

2The external static pressure used for fan selection was assumed to be divided 50% to entering duct external static

pressure and 50% discharge external static pressure.

H

J

L

Drain pan trapping for sectionunder negative pressure

L = H + J + pipe diameter where:H = 1 inch for each inch of negativepressure (loaded filters) plus 1 inch

J = 12 H

Drain pan trapping for sectionunder positive pressure

L = H + J + pipe diameter where:H = 1/2 inch (minimum)

J = 12 inch plus the unit positive static

pressure at coil discharge (loadedfilters)

Page 28: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 27 of 29

Accessory - Performance Climate ChangerFilter ScheduleItem: A1 Qty: 1 Tag(s): AHU-1

UnitTag(s)

UnitSize

FilterLocation

FilterArrangement

FilterDepth

FilterType

MERVRating

FilterQuantity

FilterSize

AHU-1 Unit size 14Filter section

[5]Angled filter

2in. filterframe

No prefilterCustomersupplied

- -

Pleated media- run set

MERV 842

20in.x20in.20in.x25in.

Page 29: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 28 of 29

Field Wiring - Performance Climate ChangerMCA MOP ScheduleItem: A1 Qty: 1 Tag(s): AHU-1

Unit Tag(s) Circuit Circuit Description Voltage/Phase/Hz MCA (A) MOP (A)

AHU-1

1Supply fanmotor(s)

460/3/60 8.38 15.07

2Exhaust fan

motor(s)460/3/60 11.75 21.15

3 Cool-dry quiet 115/1/60 0.41 0.74

Page 30: ,h ò t Z µ u ] ] ( ] ^ ] } v

Sanford Lab - Lead - Preconditioning AHU December 02, 2013

FLD = Furnished by Trane U.S. Inc. dba Trane /Installed by Others

Equipment Submittal Page 29 of 29

Field Installed Options - Part/Order Number Summary

This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or ordernumbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill ofmaterial for the job.

Product Family - Performance Climate Changer

Item Tag(s) Qty Description Model Number

A1 AHU-1 1 Performance Climate Changer ( CSAA ) CSAA014UA

Field Installed Option Description Part/Ordering Number

1 extra set

Pleated media - run set

1 extra set filters - run set

Pleated media - run set