STEEL BUILDING BY AT FOR (CONTACT) 6/ Civil & Structural Engineers 50 Punari Street Currajong, Qld 4812 Fax: 07 4725 5850 Email: [email protected] ABN 341 008 173 56 Registered Chartered Professional Engineer Regn. No. 2558980 Registered Professional Engineer (Civil & Structural) QLD Regn. No. 9985 Registered Certifying Engineer (Structural) N.T. Regn. No. 116373ES Registered Engineer - (Civil) VIC Regn. No. EC36692 Registered Engineer - (Civil) TAS Regn. No. CC5648M Mr Timothy Roy Messer BE MIEAust RPEQ Registered Professional Engineer 2558980 Signature ............................................................ Date ...................................... Registered on the NPER in the areas of practice of Civil & Structural National Professional Engineers Register FDS YRWG16128 1/6/2020 TM 6 2 STEVE HANLEY MCCARTHY STREET MULWALA MCBURNIE GROUP 03 57441111 1/6/2020 2019 X BRACING IS REQUIRED IN 3 SIDE BAY(S) AND 1 ROOF BAY(S) (BOTH SIDES). FLY BRACING IS INCLUDED TO BE PLACED ON EVERY SECOND PURLIN AND GIRT ON ENDWALL MULLIONS, INTERNAL COLUMNS AND INTERNAL RAFTERS. SCALE: SIDEWALL EXTERIOR ELEVATION 1 2 1 = 200 ROOF PURLINS PER MEMBER SCHEDULE ON SHEET 5 SCALE: SIDEWALL EXTERIOR ELEVATION 2 2 1 = 200 ROOF PURLINS PER MEMBER SCHEDULE ON SHEET 5 SIDEWALL GIRTS PER MEMBER SCHEDULE ON SHEET 5 SCALE: ENDWALL INTERIOR ELEVATION 4 2 1 = 200 ROOF PURLINS PER SCHEDULE WALL GIRTS PER MEMBER SCHEDULE ON SHEET 5 C 5 DK2 3063 437 T.O. CONCRETE 4500 1166 5666 TO PEAK TO EAVE C 5 B 5 5 E SCALE: ENDWALL INTERIOR ELEVATION 3 2 1 = 200 ROOF PURLINS PER SCHEDULE WALL GIRTS PER MEMBER SCHEDULE ON SHEET 5 C 5 3063 437 4500 1166 5666 TO PEAK TO EAVE T.O. CONCRETE C 5 B 5 5 E 1 2 3 4 5 6 7 8 9 10 11 12 13 14

GUIDE TO THE INSTALLATION OF TEMPORARY BRACING · c. the second portal frame assembly to be lifted into position. fix eave purlins and at least one purlin per 3m of rafter to secure

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

  • STEEL BUILDING BY

    AT

    FOR

    (CONTACT)

    Civil & Structural Engineers

    50 Punari Street

    Currajong, Qld 4812

    Fax: 07 4725 5850

    Email: [email protected]

    ABN 341 008 173 56

    Registered Chartered Professional Engineer Regn. No. 2558980

    Registered Professional Engineer (Civil & Structural) QLD Regn. No. 9985

    Registered Certifying Engineer (Structural) N.T. Regn. No. 116373ES

    Registered Engineer - (Civil) VIC Regn. No. EC36692

    Registered Engineer - (Civil) TAS Regn. No. CC5648M

    Mr Timothy Roy Messer BE MIEAust RPEQ

    Registered Professional Engineer 2558980

    Signature ............................................................

    Date ......................................

    Registered on the NPER in the areas of practice

    of Civil & Structural National Professional

    Engineers Register

    FD

    S

    YR

    WG

    16

    12

    8

    1/6

    /2

    02

    0

    TM

    6

    2

    STEVE HANLEY

    MCCARTHY STREET

    MULWALA

    MCBURNIE GROUP

    03 57441111

    1/6/2020

    20

    19

    X BRACING IS REQUIRED IN 3 SIDE BAY(S) AND 1 ROOF BAY(S) (BOTH SIDES).

    FLY BRACING IS INCLUDED TO BE PLACED ON EVERY SECOND PURLIN AND GIRT ON ENDWALL MULLIONS, INTERNAL COLUMNS AND INTERNAL RAFTERS.

    SCALE:

    SIDEWALL EXTERIOR ELEVATION1

    2

    1 = 200

    ROOF PURLINS PER

    MEMBER SCHEDULE ON

    SHEET 5

    SCALE:

    SIDEWALL EXTERIOR ELEVATION2

    2

    1 = 200

    ROOF PURLINS PER

    MEMBER SCHEDULE ON

    SHEET 5

    SIDEWALL GIRTS PER

    MEMBER SCHEDULE ON

    SHEET 5

    SCALE:

    ENDWALL INTERIOR ELEVATION4

    2

    1 = 200

    ROOF PURLINS

    PER SCHEDULE

    WALL GIRTS PER

    MEMBER SCHEDULE ON

    SHEET 5

    C

    5

    DK2

    3063

    437

    T.O. CONCRETE

    4500

    1166

    5666

    TO PEAK

    TO EAVE

    C

    5

    B

    5

    5

    E

    SCALE:

    ENDWALL INTERIOR ELEVATION3

    2

    1 = 200

    ROOF PURLINS

    PER SCHEDULE

    WALL GIRTS PER

    MEMBER SCHEDULE ON

    SHEET 5

    C

    5

    3063

    437

    4500

    1166

    5666

    TO PEAK

    TO EAVE

    T.O. CONCRETE

    C

    5

    B

    5

    5

    E

    1 2 3 4 56 7

    8 9 10 11 12 13 14

  • STEEL BUILDING BY

    AT

    FOR

    (CONTACT)

    Civil & Structural Engineers

    50 Punari Street

    Currajong, Qld 4812

    Fax: 07 4725 5850

    Email: [email protected]

    ABN 341 008 173 56

    Registered Chartered Professional Engineer Regn. No. 2558980

    Registered Professional Engineer (Civil & Structural) QLD Regn. No. 9985

    Registered Certifying Engineer (Structural) N.T. Regn. No. 116373ES

    Registered Engineer - (Civil) VIC Regn. No. EC36692

    Registered Engineer - (Civil) TAS Regn. No. CC5648M

    Mr Timothy Roy Messer BE MIEAust RPEQ

    Registered Professional Engineer 2558980

    Signature ............................................................

    Date ......................................

    Registered on the NPER in the areas of practice

    of Civil & Structural National Professional

    Engineers Register

    FD

    S

    YR

    WG

    16

    12

    8

    1/6

    /2

    02

    0

    TM

    6

    3

    STEVE HANLEY

    MCCARTHY STREET

    MULWALA

    MCBURNIE GROUP

    03 57441111

    1/6/2020

    20

    19

    Refer to Sheet #4 for concrete specification.

    SCALE:

    INTERNAL FRAME SECTION1

    3

    1 = 100

    5

    B

    A

    5

    5

    F

    5

    Q5

    P

    COLUMN AND RAFTER SIZE

    PER MEMBER SCHEDULE

    ON SHEET 5

  • STEEL BUILDING BY

    AT

    FOR

    (CONTACT)

    Civil & Structural Engineers

    50 Punari Street

    Currajong, Qld 4812

    Fax: 07 4725 5850

    Email: [email protected]

    ABN 341 008 173 56

    Registered Chartered Professional Engineer Regn. No. 2558980

    Registered Professional Engineer (Civil & Structural) QLD Regn. No. 9985

    Registered Certifying Engineer (Structural) N.T. Regn. No. 116373ES

    Registered Engineer - (Civil) VIC Regn. No. EC36692

    Registered Engineer - (Civil) TAS Regn. No. CC5648M

    Mr Timothy Roy Messer BE MIEAust RPEQ

    Registered Professional Engineer 2558980

    Signature ............................................................

    Date ......................................

    Registered on the NPER in the areas of practice

    of Civil & Structural National Professional

    Engineers Register

    FD

    S

    YR

    WG

    16

    12

    8

    1/6

    /2

    02

    0

    TM

    6

    6

    STEVE HANLEY

    MCCARTHY STREET

    MULWALA

    MCBURNIE GROUP

    03 57441111

    1/6/2020

    20

    19

    NOTES:BRACING MATERIALS - THE SHED ERECTOR TO SUPPLY SPECIFIC BRACING.SUITABLE RIGID MEMBERS CAPABLE OF TENSION AND COMPRESSION OR OPPOSINGCHAINS OR OPPOSING LOAD RATED RATCHET STRAPS TO BE USED. (RIGID BRACINGAS SHOWN ON DIAGRAM) ROPE BRACING SUITABLE ONLY FOR SMALLER STRUCTURESIN IDEAL CONDITIONS.

    BRACING LOCATION - TEMPORARY BRACING TO BE ERECTED AS CLOSETO 45 DEGREE ANGLE AND FIXED TO THE TOP OF THE COLUMN OR MULLION TOACHIEVE THE OPTIMUM EFFECTIVENESS. IF THERE IS NOT ENOUGH SPACE FOR A45 DEGREE ANGLE, THEN 20 DEGREE ANGLE IS TO BE THE MINIMUM ANGLEALLOWED (REFER TO DIAGRAM). RIGID TEMPORARY BRACING MEMBER TO BE BOLTEDTO HEAVY ANGLE PEGS HAMMERED INTO THE GROUND OR TO A BRACKET, MASONRYANCHORED TO THE SLAB.

    BRACING REMOVAL - TEMPORARY BRACING TO REMAIN IN PLACE UNTILCLADDING IS FULLY INSTALLED WHERE POSSIBLE. IN NO CASE SHOULD TEMPORARYBRACING BE REMOVED UNTIL ALL PURLINS, GIRTS (AND PERMANENT CROSS BRACINGWHERE USED) ARE FIXED.

    SITE SAFETY - DUE CONSIDERATION TO BE GIVEN TO SITE SAFETY IN REGARDTO LOCATIONS OF BRACING AND PEGS.

    GUIDE APPLICATION - TEMPORARY BRACING AS DESCRIBED IS A MINIMUMREQUIREMENT FOR AN AVERAGE, STANDARD SITE CONDITION. PROVIDE ADDITIONALBRACING FOR MORE SEVERE AND/OR HIGH EXPOSURE SITE CONDITIONS.ADDITIONAL BRACING TO BE USED AS AND WHERE NECESSARY TO ENSURE THATENTIRE FRAME IS RIGID THROUGHOUT CONSTRUCTION.RESPONSIBILITY FOR ENSURING STABILITY OF STRUCTURE REMAINS WITH THE BUILDER.

    TILT UP METHODFOR STRUCTURES UNDER 9M SPAN, LESS THAN 3M HIGH AND LESS THAN 12M LONG

    A. ASSEMBLE THE FIRST SIDEWALL FRAME (COMPLETE WITH WALL SHEETING, BRACING AND GUTTER) ON THE GROUND AND LIFT ASSEMBLED SIDEWALL FRAME INTO POSITION. FIX OFF TEMPORARY SIDE BRACING TO EACH END (REFER TO DIAGRAM). FIX BASE CLEATS.B. ASSEMBLE THE SECOND SIDEWALL FRAME AS PER FIRST SIDEWALL FRAME. LIFT INTO POSITION. FIX OFF TEMPORARY WALL BRACING TO EACH END (REFER TO DIAGRAM) FIX BASE CLEATS.C. FIX GABLE END RAFTERS TO COLUMNS TO TIE WALLS. PROP APEX UNTIL ENDWALL MULLION AND APEX TEMPORARY BRACE ARE FIXED OFF. IF NO MULLION IS REQUIRED THEN PROP AND BRACE APEX UNTIL CLADDING IS COMPLETE.D. INSTALL REMAINING RAFTERS. AS EACH RAFTER PAIR IS INSTALLED, AT LEAST ONE PURLIN PER 3M OF RAFTER LENGTH IS TO BE INSTALLED TO SECURE RAFTERS.E. INSTALL REMAINING PURLINSF. INSTALL KNEE AND APEX BRACES IF AND WHERE APPLICABLE.G. REPEAT FOR LEANTO'S.

    FRAME FIRST METHODFOR STRUCTURES OVER 9M SPAN, GREATER THAN 3M HIGH AND GREATER THAN 12M LONG

    A. ASSEMBLE PORTAL FRAMES ON THE GROUND (WITH KNEE AND APEX BRACES IF AND WHERE APPLICABLE). LIFT THE FIRST PORTAL FRAME ASSEMBLY INTO POSITION. FIX OFF TEMPORARY END BRACING (REFER TO DIAGRAM). FIX BASE CLEATS.B. PROP APEX UNTIL ENDWALL MULLION AND APEX TEMPORARY BRACE ARE FIXED OFF. IF NO MULLION IS REQUIRED THEN PROP AND BRACE APEX UNTIL CLADDING IS COMPLETE.C. THE SECOND PORTAL FRAME ASSEMBLY TO BE LIFTED INTO POSITION. FIX EAVE PURLINS AND AT LEAST ONE PURLIN PER 3M OF RAFTER TO SECURE FRAME ASSEMBLY. FIX BASE CLEATS. FIX TEMPORARY SIDEWALL BRACING.D. STAND REMAINING PORTAL FRAME ASSEMBLY AS PER STEP C, FIXING TEMPORARY SIDE WALL BRACING TO EVERY SECOND BAY. BRACE OTHER END PORTAL FRAME AS PER FIRST PORTAL FRAME.E. INSTALL REMAINING PURLINS AND GIRTS.F. REPEAT FOR LEANTO'S.

    TILT UP METHOD DIAGRAM

    1

    1

    FRAME FIRST METHOD DIAGRAM

    1

    2

    GUIDE TO THE INSTALLATION OF TEMPORARY BRACING(REFER TO INSTALLATION GUIDE MANUAL FOR THE TWO METHODS OF CONSTRUCTION)

    FIRST SIDEWALL FRAME

    1

    1A

    SECOND SIDEWALL FRAME

    1

    1B

    FIRST & SECOND PORTAL FRAME ASSEMBLY

    1

    2A

    COMPLETE PORTAL FRAME ASSEMBLY

    1

    2B

    TILT UP METHOD DIAGRAM

    1

    1C

    TEMPORARY BRACING LOCATION

    FRAME FIRST METHOD DIAGRAM

    1

    2C

    TEMPORARY BRACING LOCATION

  • STEEL BUILDING BY

    AT

    FOR

    NOT PART OF COUNCIL APPLICATION DOCUMENTATION

    IF YOU HAVE A ROLLER DOOR IN THE GABLE END OF YOUR SHED, CONTACT YOUR

    DISTRIBUTOR TO SEE IF MULLION NEEDS TO BE ROTATED FOR USE AS A DOOR JAMB.

    FD

    S

    YR

    WG

    16

    12

    8

    1/6

    /2

    02

    0

    TM

    STEVE HANLEY

    MCCARTHY STREET

    MULWALA

    MCBURNIE GROUP

    03 57441111

    BOLT LAYOUT PLAN

    SCALE:

    BOLT LAYOUT PLAN1

    1

    1 = 200

    27500

    12000

    12000

    BD

    4000 3900 3900 3900 3900 3900 4000

    C

    3152

    3152

    2848

    2848

    2848

    2848

    3152

    3152

    5000

    5000

    H

    K

    2500

    2500

    2500

    2500

    SLAB EDGE

    COLUMN

    BASE PLATE

    DETAIL B

    104

    102

    163

    243

    SLAB EDGE

    COLUMN

    BASE PLATE

    DETAIL C

    102

    163

    243

    66

    C FRAME

    L

    BASE PLATE

    COLUMN

    SLAB EDGE

    DETAIL D

    102

    1632

    43

    59

    SLAB EDGE

    COLUMN

    BASE PLATE

    DETAIL H

    104

    102

    163

    243

    C FRAME

    L

    BASE PLATE

    COLUMN

    SLAB EDGE

    DETAIL K

    102

    163

    243

    59