33
DELL CONFIDENTIAL 1 GREEN IT SOLUTIONS

GREEN IT SOLUTIONS

  • Upload
    koto

  • View
    36

  • Download
    0

Embed Size (px)

DESCRIPTION

GREEN IT SOLUTIONS. GREEN IS EVERYWHERE. IT CAN LEAD YOUR COMPANY’S ENVIRONMENTAL INITIATIVES. - PowerPoint PPT Presentation

Citation preview

Page 1: GREEN IT SOLUTIONS

DELL CONFIDENTIAL 1

GREEN IT SOLUTIONS

Page 2: GREEN IT SOLUTIONS

GREEN IS EVERYWHERE

DELL CONFIDENTIAL 2

Page 3: GREEN IT SOLUTIONS

IT CAN LEAD YOUR COMPANY’S ENVIRONMENTAL INITIATIVES

“IT will be a significant part of corporations’ efforts to make their internal operations greener, given its disproportionate share of energy consumption relative to headcount or overall operating costs. As a leader of an IT organization, if you haven’t gotten the knock on your door yet from someone asking how and when IT will contribute, you will.”

“Green IT is a sterling opportunity for the IT organization to be a role model for other functional groups in the company. By greening its own operations and serving as an enabler for a broader set of green business opportunities, IT can accelerate its own transformation from a service organization into a full participant in business strategy and contributor to business results.”

"Creating the Green IT Action Plan" (Forrester Research, Inc. October 19, 2007)

DELL CONFIDENTIAL 3

Page 4: GREEN IT SOLUTIONS

IT EXECS ARE PREPARING FOR SIGNIFICANT DATA CENTER CHANGE 52% are willing to pay 5% to 10% more for green

products

51% are willing to trade 5 to 10 percent of server performance for lower carbon emissions

42% say their companies don’t monitor IT-related energy spending

12% say energy efficiency is a critical issue when buying IT equipment following reliability (63%), price (32%) and after-sales support (30%)

DELL CONFIDENTIAL 4Sources: Rackspace study of 380 customers in 2007, Economist Intelligence Unit

Page 5: GREEN IT SOLUTIONS

ACHIEVING YOUR ORGANIZATION ITS GREEN OBJECTIVES

CONTRIBUTE TO CORPORATE SOCIAL RESPONSIBILITY AND GREEN INITIATIVES

REDUCE OVERALL ELECTRICITY CONSUMPTION AND SPEND

IMPROVE UTILIZATION OF IT EQUIPMENT

Creating the Green IT Action Plan" (Forrester Research, Inc. October 19, 2007)

DELL CONFIDENTIAL 5

Page 6: GREEN IT SOLUTIONS

DELL CONFIDENTIAL 6

POWER & COOLING SOLUTIONS

Page 7: GREEN IT SOLUTIONS

ENERGY ISSUES INHIBIT BUSINESS INNOVATION AND GROWTH

Power limitations Cooling capabilities maxing out Increasingly difficult to manage hot spots Space at a premium Power / Cooling costs greater than cost of IT

equipment Unnecessary energy use / expense Performance demands increasing Energy costs rising dramatically

DELL CONFIDENTIAL 7

Page 8: GREEN IT SOLUTIONS

DELL CONFIDENTIAL 8

THE POWER & COOLING CHALLENGE

Page 9: GREEN IT SOLUTIONS

GLOBAL ELECTRICITY PRICES HAVE INCREASED 56% SINCE 2002

DELL CONFIDENTIAL 9Energy Information Administration: http://www.eia.doe.gov/emeu/international/elecprii.html

$0.040

$0.050

$0.060

$0.070

$0.080

$0.090

$0.100

2002 2003 2004 2005 2006

Pric

e pe

r kW

h (in

US$

)

World Average Electricity Prices 2002-2006

World Average

North America

EMEA

Asia

Page 10: GREEN IT SOLUTIONS

50% OF DATACENTERS WILL LACK SUFFICIENT POWER & COOLING BY 2008

Source: EPA Report to Congress on Server and Data Center Energy Efficiency; August 2, 2007

2.9% of projected total U.S. electricity use

1.2% of total U.S.electricity use

0.8% of total U.S.electricity use

Page 11: GREEN IT SOLUTIONS

FACILITIES GENERALLY OWNS THE ELECTRIC BILL

DELL CONFIDENTIAL 11Source: InformationWeek Research, Green Datacenter Study, September 2007

IT receives incentives from management to

keep electric costs low

IT pays the electric bill: if IT saves on

electricity, the savings can be spent elsewhere

IT sees the bill and is

responsible for minimizing it

IT is aware of the electric bill, but

isn't responsible for managing it

The Facilities team gets the

electric bill and IT never sees it

How does your company track datacenter power usage?

56%

6% 3%

13%

21%

Page 12: GREEN IT SOLUTIONS

CONFLICTS BETWEEN IT AND FACILITIES AGENDAS RESULT IN INEFFICIENCIES

IT DEPARTMENTWhat are the upcoming datacenter changes?

Consolidations and expansions New redundancy requirements Incremental power requirements

Does my IT facility (space, power and cooling capacity) fully support initiatives such as Server Consolidation, Virtualization or HPCC initiatives?

Are the existing server room/data center cooling systems adequate to support the new equipment?

Are the existing server room/data center power distribution systems adequate to support the new equipment/future growth?

What would a major business disruption cost my company per hour? What percentage is related to environmental factors?

FACILITIES DEPARTMENTThe utility company won’t let me have

any more power… I have exceeded the capacity of my

rack… I am literally running out of space… I cannot deploy any more servers until

we bring a new DC online…Power is costing more than my

equipment… I am running out of breakers…The only way I can put another server in

is if I take one out…

Page 13: GREEN IT SOLUTIONS

SERVERS, PCs & MONITORS DRIVE MORE THAN 60% OF GLOBAL ICT RELATED CO2 EMISSIONS

Source: Gartner, April 2007

Page 14: GREEN IT SOLUTIONS

IT Equipment

41%

Power Delivery

28%

Cooling Equipment

31%

Share of Energy Use in a Typical Datacenter

POWER & COOLING ACCOUNT FOR 59% OF TOTAL ENERGY CONSUMPTION

DELL CONFIDENTIAL 14

– A positive change in the energy usage of IT equipment has a direct affect on power and cooling requirements

– A 10% improvement at the server level nets almost 10% at the facility level

– However, efficiency improvements in cooling or power delivery are relatively independent

– 10% betterment in power delivery efficiency manifests itself as a 2.8% improvement at the facility level

Page 15: GREEN IT SOLUTIONS

DELL CONFIDENTIAL 15

Compute Servers

63%

Storage22%

Comms and other IT

Equipment15%

Breakdown of Energy Use by IT Equipment

In a 100 kWh datacenter, only 25.8

kWh is used by compute servers

IT Equipment

41%

Power Delivery

28%

Cooling Equipment

31%

Share of Energy Use in a Typical Datacenter

COMPUTE SERVERS ACCOUNT FOR 63% OF IT EQUIPMENT ENERGY USE

Page 16: GREEN IT SOLUTIONS

CPU32%

CPU VR Loss8%

Memory6%

Chipset4%

HDD/RMSD13%

PSU21%

Other16%

Energy Usage by Components of Compute Servers

POWER EFFICIENCY OF THE SERVER IS ABOUT ALL OF THE COMPONENTS, NOT JUST THE CPU & PSU

DELL CONFIDENTIAL 16

Compute Servers

63%

Storage22%

Comms and other IT

Equipment15%

Breakdown of Energy Use by IT Equipment

IT Equipment

41%

Power Delivery

28%

Cooling Equipment

31%

Share of Energy Use in a Typical Datacenter

Page 17: GREEN IT SOLUTIONS

73%

46%

40%

40%

36%

27%

22%

20%

20%

CRACs

Raised floor, forced air thru tiles

Supplemental Air conditioners

Air distribution units

Rack enclosures with built in cooling

Blanking panels within / between each rack

Heat rejection units

Aisle enclosures for hot aisle containment

Hot / cold aisle configuration

Which of the following do you have installed in your datacenter to deal with cooling?

SIMPLE TO IMPLEMENT, HIGH IMPACT BEST PRACTICES ARE INFREQUENTLY USED

DELL CONFIDENTIAL 17

Sources: IDC Datacenter Power and Cooling Trends June 2007

Page 18: GREEN IT SOLUTIONS

MIXING OF HOT AND COLD AIR INCREASES AS SERVER ENERGY CONSUMPTION RISES

DELL CONFIDENTIAL 18

Absence of cold air means that the probability of

component failure increases.

The racks shown that don’t have blue all the way to the

top have reached their cooling capacity.

Page 19: GREEN IT SOLUTIONS

216% INCREASE IN PERFORMANCE, 42% LESS ENERGY REQUIRED

DELL CONFIDENTIAL 19

176

347

405

234

48 57

114

360

PowerEdge 1650 PowerEdge 1750 PowerEdge 1850 PowerEdge Energy Smart 1950

Single System Power vs. Performance per Watt

Watts Ops/Sec per Watt

Source: Dell White Paper: PERFORMANCE AND ENERGY ADVANTAGES OF DELL ENERGY SMART SERVERS AND LIEBERT COOLING SYSTEMS

Page 20: GREEN IT SOLUTIONS

0%

5%

10%

15%

20%

25%

30%

35%

40%

45%

Power Delivery Cooling Equipment

Compute Servers

Storage, Comms and Other IT Equipment

Share of Datacenter Energy Use

IN TYPICAL DATA CENTERS, COMPUTE SERVERS ACCOUNT FOR LESS THAN 30% OF ENERGY CONSUMPTION

DELL CONFIDENTIAL 20

Source: Dell PS3 Data Center Study, Fall 2006

Page 21: GREEN IT SOLUTIONS

-

10

20

30

40

50

60

70

80

90

100

Base 10% Efficiency Improvement in Servers

kW

Impact of Server Efficiencies on Overall Datacenter Energy Consumption

-

10

20

30

40

50

60

70

80

90

100

Base 10% Improvement in Cooling Equipment

kW

Impact of Cooling Equipment Efficiencies on Overall Datacenter Energy Consumption

SERVER EFFICIENCY DRIVES IMPROVEMENT AT THE DATA CENTER LEVEL

DELL CONFIDENTIAL 21

Source: Dell PS3 Data Center Study, Fall 2006-

10

20

30

40

50

60

70

80

90

100

Base 10% Efficiency Improvement in Servers

kW

Impact of Server Efficiencies on Overall Datacenter Energy Consumption

Storage, Comms and Other IT Equipment

Compute Servers

Cooling Equipment

Power Delivery

Net 4%

-

10

20

30

40

50

60

70

80

90

100

Base 10% Efficiency Improvement in Servers

kW

Impact of Server Efficiencies on Overall Datacenter Energy Consumption

Storage, Comms and Other IT Equipment

Compute Servers

Cooling Equipment

Power Delivery

Net 8%

Page 22: GREEN IT SOLUTIONS

POWER MONITORING

Power Monitoring for servers supporting PMBus will report – Amperage per power

supply

– Power consumption and total energy consumed

– Peak power and Peak amperage per server

– Energy and Power consumption per Blade

– Aggregation of power and energy consumed for group of servers

Dell OpenManage IT Assistant - Microsoft Internet ExplorerDell OpenManage IT Assistant - Microsoft Internet Explorer

Applet OMCF.ui.MainApplet Started

Performance/Power Monitoring Tasks

My power monitoring (Windows)

Summary Execution Logs

Name Current Value Average Value Minimum Value Maximum Value

Aggregate Energy Consumed

Aggregate Power Consumed2500 KWh

600 W

-NA-

450 W

-NA-

300 W

-NA-

800 W

Percentage Time

-NA-

Peak Value Observed at..

-NA-

03/02/07 5:22PM

Summary Group Summary and Maximum ValuesExecution Results

140 W

110 W

300 W

200 W

110 W

90 W

192.168.22.179

Wxp-gjp1m1s

jt9771s

jr9771s

myserver

bgdb71s

13 A

12 A

8 A

11 A

14 A

16 A

06/08/07 2:22 PM

05/08/07 4:21 AM

08/09/06 3:33 PM

12/08/07 2:30 PM

06/06/07 6:21 AM

05/07/07 5:00 PM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

05/05/06 4:20 AM

Device Peak Power Peak Amperage Peak Time Peak Measured Since Energy Measured Since

Aggregate consumption, with the option of setting

thresholds on the aggregate watts

consumed

View Chart/Export data menu, similar to

individual attributes

Average/max/Min for the given

Power Supply/System

Chart View of the collected data

Line graph/Export

Menu

Page 23: GREEN IT SOLUTIONS

23

Scop

e o

f M

an

ag

ed

En

vir

on

men

t

Scope of Virtual Infrastructure

Pervasive Virtualized Infrastructure

VIRTUALIZATION EVOLUTIONPRESENTS NEW CHALLENGES

Discrete Hypervisor Silos

• Institutional resistance

• Implementation & operational policy

• Integration w/ mgt. tools & processes

• VM lifecycle (image & licensing)

• Technology rationalization & alignment

Page 24: GREEN IT SOLUTIONS

UNLOCK YOUR HIDDEN DATA CENTER

VIRTUALIZATION

DELL CONFIDENTIAL 24

Page 25: GREEN IT SOLUTIONS

LOW SERVER UTILIZATION RATES WASTE ENERGY

Source: Dell SPA Lab Study, November 2, 2007

0

50

100

150

200

250

300

350

400

0.00%

10.00%

20.00%

30.00%

40.00%

50.00%

60.00%

70.00%

80.00%

90.00%

100.00%

1 35 69 103

137

171

205

239

273

307

341

375

409

443

477

511

545

579

613

647

681

715

749

783

817

851

885

919

953

987

1021

1055

Watt

s

CPU

Uti

lizati

on

Dell PowerEdge 2950 Utilization vs. Power Draw

Watts

CPU Utilization

Page 26: GREEN IT SOLUTIONS

VIRTUALIZATION ENABLES INCREASED SERVER UTILIZATION

DELL CONFIDENTIAL 26

0

50

100

150

200

250

300

350

400

450

500

0

5000

10000

15000

20000

25000

Standard PowerEdge 2650 Virtualized PowerEdge 2950

Per

form

ance

(O

PM

)

Dell PowerEdge 2650 vs. 2950: Performance & Power Draw

Source: Competitive Power Savings with VMware Consolidation on the Dell PowerEdge 2950, Dell Tech Center, August 2007

Watts

Performance (OPM)

Page 27: GREEN IT SOLUTIONS

UNLOCK YOUR HIDDEN DATA CENTER: AN ILLUSTRATIONBASELINE

ASSUMPTIONS: TYPICAL LARGE DATA

CENTER

5000 SERVERS– ~29 servers / rack

– 10% 5+ years old

– 70% 2-5 years old

– 20% <2 years old

WORKLOADS = 4750

PUE = 2.23

Cooling vs. IT Power draw: 92.6 to 100 watt ratio

DELL CONFIDENTIAL 27

Source: Based on Dell PS3 Data Center Study, Fall 2006

0

1000

2000

3000

4000

5000

6000

Number of Servers Server Power Consumption (kW)

Workloads

Unlocking the Hidden Data Center: Baseline Servers, Power Consumption and Workloads

Page 28: GREEN IT SOLUTIONS

BEST PRACTICE: RAISING DATA CENTER SET POINT LEADS TO GREATER EFFICIENCY1.Chiller cooling efficiency

improves with increased water temperature

2.Increased water temperature enables an increase in temperature of the air handler coil

3.Incorporating Variable Frequency Drive blowers into air handlers enables greater efficiency

DELL CONFIDENTIAL 28

9.8

10

10.2

10.4

10.6

10.8

11

11.2

44 46 48 50 52 54 56

BT

U/H

R C

oo

lin

g /

Ch

ille

r W

att

Water Temperature

Air Cooled Chiller Efficiency

0%

20%

40%

60%

80%

100%

120%

60% 65% 70% 75% 80% 85% 90% 95% 100%

Fan

Po

wer

an

d F

low

rate

(%

of

full

)

Air Handler Load %

Fan Power at Partial Load

Page 29: GREEN IT SOLUTIONS

UNLOCK YOUR HIDDEN DATA CENTER: AN ILLUSTRATIONOPTIMIZED DATA CENTER TEMPERATURE

DELL CONFIDENTIAL 29

Data center temperature raised 5 degrees

No change in servers, server power or workloads

5% reduction in Total Data Center Power Consumption

Cooling vs. IT Power draw: 80.5 to 100 watt ratio (13% improvement)

Improvement at overall data center: PUE drops from 2.23 to 2.12

0

1000

2000

3000

4000

5000

6000

Number of Servers Server Power Consumption (kW)

Workloads Total Data Center Power Consumption

Unlocking the Hidden Data Center: Servers, Power Consumption and Workloads w/

Optimized Facility Temperature

Baseline Optimize Facility Temperature

5%

Page 30: GREEN IT SOLUTIONS

SERVER OPTIMIZATION RECOMMENDATIONS

CONSOLIDATE 5+ YEAR OLD: Remove 50% Refresh 25% with

Energy Smart servers Leave 25% as is

2-5 YEAR OLD: Refresh / consolidate

20%, 75% of new servers are Energy Smart

DELL CONFIDENTIAL 30

VIRTUALIZE 2-5 YEAR OLD: Refresh 40% with

virtualized systems

<2 YEAR OLD: Refresh with 32%

virtualized systems

Page 31: GREEN IT SOLUTIONS

0

1000

2000

3000

4000

5000

6000

Number of Servers Server Power Consumption (kW)

Workloads Total Data Center Power Consumption

Unlocking the Hidden Data Center: Comparison of Servers, Power Consumption and Workloads

Baseline Optimize Facility Temperature Optimize Servers

REDUCE DATA CENTER POWER CONSUMPTION UP TO 45% WITH NO PERFORMANCE CHANGE

DELL CONFIDENTIAL 31

No change

39%

42%

45%

Page 32: GREEN IT SOLUTIONS

0100020003000400050006000700080009000

10000

Number of Servers Server Power Consumption (kW)

Workloads Total Data Center Power Consumption

Unlocking the Hidden Data Center: Comparison of Servers, Power Consumption and Workloads

Baseline Optimize Facility Temperature

Optimize Servers Fill "Hidden Data Center"

UNLOCK YOUR HIDDEN DATA CENTER: INCREASE PERFORMANCE UP TO 97%

DELL CONFIDENTIAL 32

97%

No change

PUE = 2.23

PUE = 2.12 PUE = 2.02

PUE = 2.12

Cooling vs. IT Power draw: 73.8 to 100 watt ratio (8% improvement)

Page 33: GREEN IT SOLUTIONS

THANK YOU

DELL CONFIDENTIAL 33