11
© copy right reserved by GoodWe GoodWe Three-Phase Photon Test Report

GoodWe Three-Phase Photon Test Report

  • Upload
    virgo

  • View
    134

  • Download
    0

Embed Size (px)

DESCRIPTION

GoodWe Three-Phase Photon Test Report. Inverter GW17K-DT. Conversion Efficiency ( Symmetrical DC- loadcase ). Power one 2012-9 Trio -20.0-TL-OUTD-S2-400. Delta Energy 2012-3 Solivia 20 EU G3 TL. Refusol 2012-3 020K. Helios 2012-3 HSI20. Samil Power 2012-6 SolarLake 15000TL. - PowerPoint PPT Presentation

Citation preview

Page 1: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

GoodWe Three-Phase Photon Test Report

Page 2: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Inverter GW17K-DT

Page 3: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Conversion Efficiency ( Symmetrical DC-loadcase )Power one 2012-9 Trio -20.0-TL-OUTD-S2-400

Delta Energy 2012-3 Solivia 20 EU G3 TL

Helios 2012-3 HSI20 Refusol 2012-3 020K Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 4: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

MPPT-Efficiency Summation Tracker ( Symmetrical DC-loadcase )Power one 2012-9 Trio -20.0-TL-OUTD-S2-400

Delta Energy 2012-3 Solivia 20 EU G3 TL

Helios 2012-3 HSI20 Refusol 2012-3 020K Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 5: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Overall-Efficiency ( Symmetrical DC-loadcase )

Power one 2012-9 Trio -20.0-TL-OUTD-S2-400

Delta Energy 2012-3 Solivia 20 EU G3 TL

Helios 2012-3 HSI20 Refusol 2012-3 020K Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 6: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Overall-Efficiency (Asymmetrical DC-loadcase)

Power one 2012-9 Trio -20.0-TL-OUTD-S2-400

Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 7: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Accuracy of Display of Output Power of InverterPower one 2012-9 Trio -20.0-TL-OUTD-S2-400

Delta Energy 2012-3 Solivia 20 EU G3 TL

Helios 2012-3 HSI20 Refusol 2012-3 020K Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 8: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Thermal Test

Power one 2012-9 Trio -20.0-TL-OUTD-S2-400

Delta Energy 2012-3 Solivia 20 EU G3 TL

Helios 2012-3 HSI20

Refusol 2012-3 020K

Samil Power 2012-6 SolarLake 15000TL

Eversolar 2012-4 Eversol-TLC 17K

Page 9: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

<1W

Page 10: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Page 11: GoodWe Three-Phase Photon Test Report

© copy right reserved by GoodWe

Thanks for your attention!