35

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Embed Size (px)

Citation preview

Page 1: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization
Page 2: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Goals of a Fire Prevention Program

• Fire Prevention Strategy

• Housekeeping Issues

• Flammable and Combustible Liquids

• Electrical Fire Hazards

• Compartmentalization

TopicsTopics

Page 3: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Life Safety– The primary goal of fire safety efforts is to protect

building occupants from injury and to prevent loss of life.

• Property Protection– The secondary goal of fire safety is to prevent

property damage.

• Protection of Operations– By preventing fires and limiting damage we can

assure that work operations will continue.

Fire Prevention GoalsFire Prevention Goals

Page 4: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

The Strategy of Preventing a Fire The Strategy of

Preventing a Fire

• A fire must have three things to ignite and maintain combustion:– Fuel– Heat – Oxygen

• The basic strategy of fire prevention is to control or isolate sources of fuel and heat in order to prevent combustion.

If all three are not present in sufficient quantities a fire will not ignite or a fire will not be able to sustain combustion

Page 5: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Good housekeeping habits are an important part of a safe workplace.

• Why is good housekeeping important?– To reduce amounts of flammable and combustible

materials. – To reduce ignition hazards.– To ensure safe emergency evacuation of

occupants.– To allow for quick emergency response.

HousekeepingHousekeeping

Page 6: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

General Housekeeping Guidelines

General Housekeeping Guidelines

• Work areas, aisles, walkways, stairways, and equipment should be kept clear of loose materials, trash, scraps, etc.

• Never block aisles, fire exits, emergency equipment, or alarm pull stations with equipment or materials.

• Avoid build up of combustible trash and waste such as paper, wood, cardboard, etc.

• Keep use and storage of flammables and combustibles to a minimum.

• Clean up all spills such as grease, oil, or water immediately. A delay could result in accidents.

Page 7: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Storage GuidelinesStorage Guidelines

• No storage is allowed in corridors and stairwells. A cluttered hallway could slow down emergency evacuation.

• Storage must not exceed a plane of 18 inches below sprinkler heads or smoke detectors. Storage that breaks this plane may prevent sprinkler heads from fully covering room during a fire. A simulated example of how

storage can protrude into 18 inch plane below sprinkler heads.

Page 8: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• All storage must be at least 3 ft from electrical panels. In some emergency situations it will be necessary to access these panels quickly.

• Maintain at least a 3ft clearance from heating surfaces, air ducts, heaters, and lighting fixtures.

• Storage of combustible materials in mechanical rooms is prohibited.

Improper Storage in front of Electrical Panel

Improper Mechanical Room Storage

Storage GuidelinesStorage Guidelines

Page 9: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Flammable and combustible liquids are potential fuel sources for fires and are present in almost every workplace.

• It is actually the vapor created by flammable and combustible liquids that ignites and burns.

• It is important to understand what materials in your work area are flammable and combustible so that you may properly store and isolate them from ignition sources.

Flammable and Combustible Liquids

Flammable and Combustible Liquids

Page 10: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• NFPA classification system– The NFPA diamond is an easy way to determine the safety

risks associated with hazardous materials. To determine a materials flammability refer to the red section of the diamond. A number in this section will indicate the flammability rating of the material.

• The following numbering system is used to indicate flammability

0- will not burn

1- must be preheated to burn

2-ignites when moderately heated

3-ignites at normal temperature

4-extremely flammable

How do I tell what’s flammable?How do I tell what’s flammable?

For example, An NFPA diamond on a can of gasoline would have a 3 in the red section indicating that gasoline could ignite at normal working temperatures.

NFPA Diamond

Page 11: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

NFPA Classification System Continued...

NFPA Classification System Continued...

• Where can I find NFPA diamonds?– Product labels– Material Safety Data Sheets (ask your supervisor

for them)

• How do I determine the flammability of chemicals that don’t use the NFPA classification system?– The flashpoint of a chemical may be used to

determine its flammability. Flashpoint information may be found on product labels or MSDS sheets.What’s a

Flashpoint?

The flashpoint of a liquid is the lowest temperature at which the liquid gives off enough vapor to be ignited. The lower the flashpoint, the greater the risk for ignition.

Page 12: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Flammable and Combustible Liquids Continued...

Flammable and Combustible Liquids Continued...

• Flammable liquids are considered flammable because their flashpoints are < 100ºF. This means that flammable liquids burn easily at normal working temperatures.

• Combustible liquids have a flashpoint at or above 100ºF. These liquids are less hazardous than flammable liquids but still pose a risk.

• The volatility of flammable and combustible liquids requires special storage and handling requirements.

Page 13: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Flammable liquids must be stored away from ignition sources in cool, well ventilated areas away from incompatible materials

• Limit the amount of flammable and combustible liquids to the minimum amount necessary.

• As a general rule, No more than 10 gallons of flammable materials should be outside of approved flammable liquid storage cabinets or approved storage rooms.

• Room storage limits of flammable and combustible materials depend on various factors such as sprinklers, and storage cabinets. Refer to the table on the following slide for storage guidelines.

Storing Flammable and Combustible Liquids

Storing Flammable and Combustible Liquids

Page 14: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Table 1. Room Storage Limits for Flammable and Combustible LiquidsClass ofLiquid

Flashpoint(°F)

Boilingpoint(°F)

NonSprinkledBuilding

NonSprinkled Bldg. &Flammable LiquidStorage Cabinet

SprinkledBuilding

SprinkledBldg./FlammableLiquid StorageCabinet

Class 1A,Flammables

<73 °F <100 °F 10 gal. 20 gal. 10 gal 40 gal.

Class 1BFlammables

<73 °F >100 °F 10 gal. 40 gal. 10 gal 80 gal.

Class 1CFlammable

> 73 &<100 °F

NA 10 gal. 60 gal. 10 gal 120 gal.

Class IICombustibles

>100 &<140 °F

NA 30 gal. 60 gal. 60 gal. 90 gal.

Class III-ACombustibles

>140&<200°F

NA 50 gal. 100 gal. 100 gal. 150 gal.

Note: Containers other than safety cans shall not be greater capacity than one (1) gallon. The number oftwo (2) gallon safety cans shall not exceed five (5). The number of one (1) gallon safety cans in useoutside storage cabinets shall not exceed ten (10).

It may be possible to exceed these limits check with your local fire department for applicable local fire codes.

General Guidelines for Safe Storage

General Guidelines for Safe Storage

Page 15: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Electrical hazards are the cause of numerous workplace fires each year. Faulty electrical equipment or misuse of equipment produces heat and sparks that serve as ignition sources in the presence of flammable and combustible materials.

• Examples of common ignition hazards:– overloading circuits– use of unapproved electrical devices– damaged or worn wiring

Fire SafetyElectrical Issues

Fire SafetyElectrical Issues

Page 16: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Extension cords– Extension cords are only approved for temporary

use. They may only be used for a period of three days or less. Instead of using extension cords install permanent wiring.

– When using extension cords check for defaults such as frays, brittleness, or broken wires.

– Never place extension cords in high traffic areas where they can be damaged by being stepped on or run over by equipment.

Electrical Fire SafetyElectrical Fire Safety

Page 17: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Multi-plug strips – Should only be used for office equipment such as

computers, printers, and fax machines. – Other common items such as microwaves,

refrigerators, and copy machines must be plugged directly into wall outlets. This is a requirement of the State Fire Marshal.

– Multi-plug strips should have a fuse or circuit breaker and be UL approved.

Electrical Fire SafetyElectrical Fire Safety

Page 18: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Avoid the following improper and hazardous practices:– Never use three prong

adapters that allow a three pronged plug to plug into a two prong outlet.

– Never use any item with a damaged or frayed electrical cord.

– Space Heaters are an area of concern and combustible materials should be cleared to a minimum of three feet.

– Never daisy chain or piggy back multi-plug strips and electrical cords (plugging strips and cords into each other).

Piggy-backed multi-plug strips

Electrical Fire SafetyElectrical Fire Safety

Page 19: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Buildings are designed to prevent fire, heat, and smoke from spreading beyond locations of origination. Building elements such as fire walls, fire dampers, and fire doors, are designed to seal off one location from the next. This system is called compartmentalization.

• Compartmentalization increases the safety of evacuating building occupants because smoke and fire are not able to escape into exit passageways.

• Containment of fire and smoke reduces property damage and prevents small fires from growing into large fires.

• In order for compartmentalization efforts to be effective fire barriers must be maintained.

CompartmentalizationCompartmentalization

Page 20: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

What’s A Fire Door?What’s A Fire Door?

• Fire doors are designed to withstand fire, heat and smoke for a period of 20-minutes to 3 hours.

• Did you know that corridor office doors are fire doors and should have a 20 minute rating?

• Corridor doors (doors leading to fire exits) should have a 60 minute rating.

• Fire Doors are required to:– Be Self Closing: fire doors

should have a door closure that pulls doors completely shut after the door has been opened

– Have Positive latching: a positive latch locks a door in place so can open swing open freely.

Page 21: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

4 Reasons Not to Wedge Open Fire Doors

4 Reasons Not to Wedge Open Fire Doors

1 For the safety of your buildings occupants. – If a fire occurs in a location

where the fire door has been wedged, smoke and heat will travel freely into exit corridors hindering or preventing occupant evacuation.

2 It’s the Law– Periodically State Fire

Marshal’s inspect businesses and issue numerous citations for wedging or blocking open doors.

3 To reduce or prevent damage to property, research, personal belongings, etc.- Keeping your door shut will

keep out smoke or fire originating in other locations.

4 To hold open your door you may have an electro-magnetic device installed.- This device releases a fire

door upon activation of the fire alarm allowing it to close and latch.

Page 22: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Maintaining Fire BarriersMaintaining Fire Barriers

• Fire doors need occasional maintenance and repairs to function properly and should be periodically checked. To test a fire door:– Open the door fully and allow it to swing shut.

– The door should close and latch completely by itself. Give the door a push after it closes to ensure that the latch has engaged.

– If the door is not operating properly contact supervisor immediately for repairs.

• Ceiling, Floor, Wall Penetrations– All areas should be properly sealed to prevent the escape of fire,

heat and smoke.

– Common penetrations include holes in walls, around ducts, pipes, etc. These types of penetrations should be sealed with appropriate fire-stopping material.

Page 23: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

1910.157Portable Fire Extinguishers

1910.157Portable Fire Extinguishers

• Requirements– Placement– Use– Maintenance – Testing

Page 24: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Portable Fire ExtinguishersPortable Fire Extinguishers

If portable fire extinguishers are provided for employee use, the employer must mount, locate and identify them so workers can access them without subjecting themselves to possible injury.

Blocked extinguisher

Page 25: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Extinguisher ClassificationExtinguisher Classification

• Class A – ordinary combustibles (wood, cloth, paper)

• Class B – flammable liquids, gases, greases• Class C – energized electrical equipment• Class D – combustible metals

Letter classification given an extinguisher to designate the class or classes of fire on which it will be effective.

A B C D

Ordinary

Combustibles

Combustible

Metals

Flammable

Liquids

Electrical

Equipment

Page 26: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Extinguisher RatingExtinguisher Rating• Numerical rating given to Class A and B

extinguishers which indicate how large a fire an experienced person can put out with the extinguisher

• Ratings are based on tests conducted at Underwriters’ Laboratories, Inc. – Class A: 1-A, 2-A, . . . 40-A– Class B: 1-B, 2-B, . . . 640-B

• A 4-A extinguisher, for example, should extinguish about twice as much fire as a 2-A extinguisher

Page 27: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Maintaining Portable Fire Extinguishers

Maintaining Portable Fire Extinguishers

• Must maintain in a fully charged and operable condition

• Must keep in their designated places at all times except during use

• Must conduct an annual maintenance check

• Must record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less

Page 28: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Portable Fire ExtinguisherTraining and Education

Portable Fire ExtinguisherTraining and Education

• Where portable fire extinguishers have been provided for employee use in the workplace, employees must be provided with an educational program on the:– General principles of fire

extinguisher use– Hazards of incipient (beginning)

stage fire fighting• Employees designated to use

extinguishers must receive instruction and hands-on practice in the operation of equipment

Page 29: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

– Training and Education• Employees shall be educated in

– Use of extinguishers– Associated Hazards– Initially and Annually

• Employees designated to use fire fighting equipment shall be trained

1910.157Portable Fire Extinguishers

1910.157Portable Fire Extinguishers

Page 30: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

P.A.S.S.P.A.S.S.

Page 31: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Selection and Distribution– Based on Classes of anticipated workplace

fires– On size and degree of hazard

1910.157Portable Fire Extinguishers

1910.157Portable Fire Extinguishers

Page 32: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

– Extinguishers shall be distributed so that maximum travel distances apply:

– Class A 75 feet– Class B 50 feet– Class C Based on appropriate pattern– Class D 75 feet

1910.157Portable Fire Extinguishers

1910.157Portable Fire Extinguishers

Page 33: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

– Inspection, Maintenance and Testing• Extinguishers shall be:• Visually inspected monthly• Maintained annually• Hydrostatically tested periodically IAW

Table L-1

1910.157Portable Fire Extinguishers

1910.157Portable Fire Extinguishers

Page 34: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

• Housekeeping Issues– Keep your worksite clean and free of trash and debris.– Follow proper storage guidelines.

• Flammable and Combustible Liquids– Use and store the minimum amounts necessary. – Follow correct storage guidelines.

• Electrical Fire Hazards– Don’t use unapproved electrical devices.– Avoid improper uses of multi-plugs.

• Compartmentalization– Maintain compartmentalization systems.– Don’t wedge or block open doors.

Points To RememberPoints To Remember

Page 35: Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization

Summit’s Loss Control department thanks you for your participation.

For additional safety information, forms, checklists, resources, safety

talks, and posters please visit:www.summitholdings.com.

Any Questions?Any Questions?